A-131_Add01.R1.pdf

PDF 1 MB Posted

Attached to
F-35 Alter Hangar 406 Federal contract opportunity
Solicitation number
W50S9F-21-B-0001
Issued by
Department of the Army National Guard

About this file

This solicitation seeks bids for construction services to alter an F-35 aircraft hangar. Work includes demolishing 19,913 square feet of hangar shop space and reconfiguring the area for F-35 maintenance operations including lavatories, offices, break rooms, mechanical spaces and repair shops. An additional 19,803 square feet of hangar space will be modified to accommodate F-35 aircraft, including fire suppression system modifications, aircraft make-up power and air systems, and lightning protection. Mechanical, plumbing, electrical, and technology systems work is required. The project is to be completed within 365 days of the notice to proceed.

The solicitation will include two options for a perimeter trench infill and slab. The bidding opportunity is designated as unrestricted and encourages participation from all responsible bidders. A subcontracting plan will be required from large businesses. The North American Industry Classification code is 236220 with a $39.5 million average annual revenue size standard. The project value is estimated between $10-25 million. The pre-bid conference is scheduled for February 16, 2021 with site visits following. Bids are due by March 8, 2021 and will be publicly opened. The solicitation and plans are available at beta.SAM.gov. The contracting agency is the Department of the Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 Alter Hangar 406, newest first.
File Type Posted
SF1419 Abstract of Offers - No Hubzone Preference.pdf PDF
W50S9F21B00010007.pdf PDF
406 Questions and Answers_142-143.pdf PDF
23 07 00_Add04.pdf PDF
F-001_Add03.pdf PDF
W50S9F21B00010005.pdf PDF
C-121_Add03.pdf PDF
C-504_Add03.pdf PDF
34 71 13.19_Add03.pdf PDF
01 45 00.00 10_Add03.pdf PDF
22 31 00_Add03.pdf PDF
T-121 Add03.pdf PDF
406 Questions and Answers_26-112.pdf PDF
G-001_Add02.pdf PDF
E-101_Add02.pdf PDF
01 50 00_Add02.pdf PDF
12 21 00_Add02.pdf PDF
10 14 00.20_Add02.pdf PDF
05 40 00_Add02.pdf PDF
01 78 00_Add02.pdf PDF
Asbestos and Lead Inspection.pdf PDF
Repair Roofs 406 Warranty Cert.pdf PDF
A-401_Add02.pdf PDF
04 20 00_Add02.pdf PDF
A-501_Add02.pdf PDF
A-601_Add02.pdf PDF
02 83 00_Add02.pdf PDF
01 14 00_Add02.pdf PDF
01 11 00_Add02.pdf PDF
W50S9F21B00010004.pdf PDF
C-141_Add02.pdf PDF
G-011_Add02.pdf PDF
AD101_Add02.pdf PDF
C-121_Add01.R1.pdf PDF
07 27 26_Add01.R1.pdf PDF
W50S9F21B00010003.pdf PDF
10 22 39_Add01.R1.pdf PDF
W50S9F21B00010002.pdf PDF
B.07.406 Site Visit Sign In 19Feb21.pdf PDF
B.07.406 Site Visit Sign In 22Feb21.pdf PDF
Pre-Bid Slides - F-35 406.pptx PPTX presentation
W50S9F21B00010001.pdf PDF
ATTACHMENT 1-Truax F-35 B406 XGFG182008 Specs Vol 1 of 2 Dated 31 July 2020.pdf PDF
ATTACHMENT 5-Justification and Approval Andover.pdf PDF
ATTACHMENT 4-Justification and Approval Advantor.pdf PDF
W50S9F-21-B-0001.pdf PDF
ATTACHMENT 6-Justification and Approval Monaco.pdf PDF
ATTACHMENT 8-406 Submittal Log.xlsx XLSX spreadsheet
ATTACHMENT 9-SFS Form 12.xls XLS spreadsheet
ATTACHMENT 10-PRE-BID CONFERENCE AND SITE VISIT INSTRUCTIONS.pdf PDF
Show all 50

F-35 Alter Hangar 406 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. PERMANENTLY REMOVE EXISTING MARKINGS ON BOTH THE HANGAR FLOOR.

2. REMOVE 6-INCH WIDE MARKINGS ON APRON TO 25 FEET IN FRONT OF BUILDING PRIOR TO APPLICATION OF NEW

MARKINGS. REMOVE MARKINGS ACROSS HANGAR DOOR TRACKS SO NOT TO DAMAGE FLOOR RAILS. REMOVE

MARKINGS ON APRON ASSOCIATED WITH HANGAR ONLY.

3. LINES SHOWN FOR GRAPHICAL REPRESENTATION ONLY. REFER TO KEYNOTE FOR FULL DESCRIPTION OF

LINEWORK.

4. PROVIDE STRIPING OF SAFETY LANES, LEAD-IN LINES, NOSE GEAR STOP LINES, GROUNDING POINTS, EMERGENCY EYE WASH FIXTURES, FIRE EXTINGUISHERS AND OTHER SAFETY MARKINGS. COORDINATE COLORS, STRIPING AND

GRIT LEVEL WITH THE USERS.

5. LINEWORK PRIORITY IS AS INDICATED BELOW. LINES OF A HIGHER PRIORITY SHALL BE CONTINUOUS THROUGH AND

NOT OTHERWISE OBSTRUCT LINES OF A LOWER PRIORITY.

PRIORITY 1 - RESTRICTED AREA BOUNDARY

PRIORITY 2 - ENTRY CONTROL POINT

PRIORITY 3 - RESTRICTED AREA BOUNDARY WARNING SIGN

PRIORITY 4 - HANGAR/OVERHEAD/MAN DOOR SAFETY LINE

PRIORITY 5 - VERTICAL CLEARANCE BOUNDARY LINE

PRIORITY 6 - EYEWASH/FIRE EXTINGUISHER LINE

HANGAR BAY STRIPING PLAN GENERAL NOTES:

4.707

4.707

4.719

4.711

4.7034.703

4.709

4.710

4.704

4.709

4.720

4.712

4.709

4.709 4.710 4.712

4.7104.7044.7084.709 4.7104.709

4.709

4.7114.7114.711 4.711

4.711

4.712

4.720

4.7114.711 4.7114.711

4.711

4.711 4.711

4.703

4.715

4.715

4.715

4.711

4.709

4.710

4.718

4.707

4.718

4.716

4.713

8'-6" 8'-6"

T Y

P

/2

7'-9 1/2"

53' - 11 1/2"

/4

53' - 11 1/2"

/4

52' - 11 3/4"

59' - 8 1/2"

52' - 11 3/4"

59' - 8 1/2"

/4

/4

/4

4.711

T Y P

6' - 0"

T Y

P

T Y

P

6'

TYP.6' -

0"

7' - 9 1/2"

TYP.

6' - 0"

7' - 9 1/2" 19' - 8"

/4

/4

19' - 8"

4.705

4.715

4.715

4.705

4.715

TYP.

TYP.

TYP.

TYP.

TYP.

4.705

4.715

TYP.

TYP.

4.705

4.715

TYP.

TYP.

4.705

4.715

TYP.

TYP.

TYP.

7' - 9 1/2"

TYP.

4.714

TYP.

4.711 4.711

4.715

4.7154.715

4.711

TYP.

4.703

TYP.

4.711

4.711

86' - 0 1/2"

4.713

4.713 4.7134.713

4.713

4.713

4.713

4.713

/2

/2

/2

/4

/4

" 1

/4

/4

3'-4"

WHITE LETTERING

RED BACKGROUND

LETTERING TO BE WHITE STENCILS ON

RED BACKGROUND. CENTER TEXT IN

FIELD. VERIFY TEXT AND SIZES WITH

BASE PRIOR TO INSTALLATION.

2"

DIA.

1'-6" 2"

1" HIGH BLACK LETTERS

1/2" HIGH BLACK LETTERS WITH

DATE OF TEST WHERE "DATE"

YELLOW

RED BORDER

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/2

/2

:0

:0

A

M C

R e v it L o c a l\

-1

.0

-A

-C e n tr a l-p jc

.r v t

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A L T

E R

B U

IL

D

IN

G

A-131

HANGAR MARKING

PLAN

XGFG182008ANG NO.:

3141300-190289.01

PJC

JJB

July 31, 2020

PJC

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

MARKING AND STRIPING PLAN

KEYED NOTES

4.714 RESTRICTED AREA BOUNDARY WARNING SIGN. WHITE STENCILED LETTERING ON RED BACKGROUND.

SEE DETAIL SHEET A-131.

4.715 GEAR POSITION LINE. 6" WIDE YELLOW STRIPE, 2'-0" LONG CENTERED ON LEAD-IN LINE. COORDINATE FINAL LOCATION OF NOSE GEAR POSITION LINE TO ENSURE 10'-0" CLEAR FROM REAR OF AIRCRAFT TO

RESTRICTED AREA BOUNDARY PRIOR TO PAINTING.

4.716 RESTRICTED AREA BOUNDARY WARNING SIGN. WHITE STENCILED LETTERING ON RED BACKGROUND.

SEE DETAIL SHEET A-131. ALIGN WITH INTERIOR PAINTED TEXT WARNING BOX.

4.718 HANGAR DOOR CRUSH AREA WARNING STRIPE. ALTERNATING 6" WIDE YELLOW AND BLACK LINES AT 45 DEGREE ANGLE WITH 6" WIDE YELLOW LINE AS A BORDER ON FOUR SIDES. FULL WIDTH OF DOOR

POCKET.

4.719 LEAD-IN LINE. 6" WIDE YELLOW STRIPE. EXTEND 25' BEYOND HANGAR DOOR.

4.720 VERTICAL CLEARANCE BOUNDARY LINE. 6" WIDE YELLOW STRIPE.

KEYED NOTES

4.709 MAN DOOR SAFETY LANE. ALTERNATING 6" WIDE YELLOW AND BLACK LINES AT 45 DEGREE ANGLE WITH CONTINUOUS 6" WIDE YELLOW LINE AS BORDER ON FOUR SIDES. FULL WIDTH OF DOOR AND 5'-0"

DEEP CENTERED ON DOOR.

4.710 FIRE EXTINGUISHER LINE. RED 3" WIDE STRIPE LOCATED 2'-0" FROM FIRE EXTINGUISHER

4.711 GROUNDING RECEPTACLE. REFERENCE ELECTRICAL PLANS FOR LOCATIONS AND DETAIL SHEET A-131.

4.712 RESTRICTED AREA BOUNDARY. 6" WIDE RED LINE

4.713 ENTRY CONTROL POINT (ECP). 3'-0" LONG, 6" WIDE WHITE BARS SEPARATED BY 6" WIDE GAPS

CENTERED ON THE RESTRICTED AREA BOUNDARY. 14'-0" WIDE AT CENTER OF HANGAR BAY

KEYED NOTES

4.703 NOSE GEAR STRIPE LINE. 6" WIDE YELLOW LINE LOCATED AT DIMENSIONS INDICATED

4.704 EYE WASH LINE. GREEN 3" WIDE STRIPE LOCATED 2'-0" FROM EYE WASH.

4.705 LEAD-IN LINE. 6" WIDE YELLOW STRIPE AT DIMENSIONS INDICATED.

4.707 HANGAR DOOR SAFETY LANE. ALTERNATING 6" WIDE YELLOW AND BLACK LINES AT 45 DEGREE ANGLE WITH 6" WIDE YELLOW LINE AS A BORDER ON FOUR SIDES. FULL WIDTH OF DOOR OPENING AND 5'-0"

DEEP.

4.708 OVERHEAD DOOR SAFETY LANE. ALTERNATING 6" WIDE YELLOW AND BLACK LINES AT 45 DEGREE ANGLE WITH 6" WIDE YELLOW LINE AS BORDER ON FOUR SIDES. FULL WIDTH OF DOOR OPENING AND

5'-0" DEEP WITH CENTER OF STRIPING PATTERN AT CENTER OF DOOR WHEN CLOSED.

3/4" = 1'-0"

WARNING SIGN DETAIL

3/4" = 1'-0"

GROUNDING POINT DETAIL

07/31/20 TYPE B3 FINAL

1 02/26/21 ADDENDUM - 01

Sheets
A-131 - HANGAR MARKING PLAN

File details come from the government source that posted it. Updated .