The project involves the repair and full renovation of the ground floor spaces of Maintenance Hangar Building 1001 at the 125th Fighter Wing Jacksonville International Airport to enable the F-35 Fighter Mission. The work includes demolition, new interior construction and finishes, HVAC, plumbing, electrical, lighting, grounding, fire protection, telecommunication, and access control/security systems. The estimated Period of Performance is 540 Calendar Days after Notice to Proceed. This is a Small Business Set-Aside opportunity with a NAICS code of 236220 and a $45M size standard. The project magnitude is between $10M to $20M. Failure to submit an offer on all items will result in bid rejection. The solicitation and all related information will be posted on SAM.gov. Award will be made to the responsible bidder whose bid conforms to the IFB and is most advantageous to the Government based on price and price-related factors.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
/2
0/
IS
SU
E
D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 3 5 7 9
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10
F
D
B
B-
SU
BM
IT
TA
L
- I
SS
U
E
FO
R C
O N
ST
R
U C
TI
O
N
FL
O
R
ID
A
AI
R N
AT
IO
N
AL
G U
AR
D
JA
C
KS
O
N
VI
LL
E
AN
G
B, F
LO
R
ID
A
P ar kw ay
L an e Su ite
Pe ac ht re e
C or ne rs
, G A
LI
C
EN
SE
N
U M
BE
R
S:
AR
C H
IT
EC
TU
R
E:
A
A2
EN
G
IN
EE
R
IN
G
C oA N o.
So ut ha ll
La ne
, S ui te
M ai tla nd , F
L
Te l:
(4
) 6
-2
FL
A C
O A
N o.
E B-
5t h
FI
G H
TE
R
W
IN
G J
AC
KS
O N
VI
LL
E, F
L, F-
R
EP
AI
R
H
AN
G
AR
, B
LD
G
LS
G
A2
E-002
EL
EC
TR
IC
AL
LE
G
EN
D
II
O . C
R U
Z
R . R
U C
K
B.
P
ET
TI
FO
R
D
S.
P
ER
R
Y
AM
EN
D M
EN
T
#2 3/
8/
XR
EF
s:
[2
9_
AN
SI
D _2
2x
_B or de r_
U
SA
C E]
Im ag es
La st s av ed b y:
R
U C
KR
M
T im e:
/8 /2
1:
:2
PM
pw cd m sm ith -a z0 2-pw .b en tle y.
co m :p w _p l1 \2
8\
\0
D es ig n
Se rv ic es
N M
_5
\0
El ec tri ca l\1
BI
M
_C
AD
D \X
XX
X#
#E
2.
dw g
GENERAL NOTE
THIS IS A STANDARD LEGEND.
SOME SYMBOLS MAY NOT
APPEAR ON THE DRAWINGS.
ABBREVIATIONS (CONTINUED)
MAX MAXIMUM
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MCP MOTOR CIRCUIT PROTECTOR
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MLO MAIN LUGS ONLY
MTD MOUNTED
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
N NEUTRAL
NC NORMALLY CLOSED
NO NORMALLY OPEN OR NUMBER
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOAD
PB PULL BOX
PCP PUMP CONTROL PANEL
PH PHASE
PMH POWER MANHOLE
PNL PANEL OR PANELBOARD
PR PAIR
PRI PRIMARY
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
RECPT RECEPTACLE
REQD REQUIRED
QTY QUANTITY
SA SURGE ARRESTER
SEC SECONDS OR SECONDARY
SH SHIELDED OR SPACE HEATER
SPD SURGE PROTECTIVE DEVICE
SS STAINLESS STEEL
SV SOLENOID VALVE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TC TIME TO CLOSE OR TRAY CABLE
TEL TELEPHONE
TO TIME TO OPEN
TS TWISTED SHIELDED OR THERMAL
SWITCH
TYP TYPICAL
UG UNDERGROUND
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLTS
VA VOLT AMPS
VFD VARIABLE FREQUENCY DRIVE
W WATTS, WIDTH, WITH, WIRE
WP WEATHERPROOF
XP EXPLOSION PROOF
XFMR TRANSFORMER
ABBREVIATIONS
A AMPS
AC ALTERNATING CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AL ALUMINUM
AIC AMPERE INTERRUPTING CAPACITY
AMP AMPERE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AWG AMERICAN WIRE GAUGE
BKR BREAKER
BLDG BUILDING
C CONDUIT
CB CIRCUIT BREAKER
CGD COMBUSTIBLE GAS DETECTOR
CKT CIRCUIT
CLB CURRENT LIMITING BREAKER
CLF CURRENT LIMITING FUSE
CP CONTROL PANEL
CPT CONTROL POWER TRANSFORMER
CR CONTROL RELAY
CS CONTROL SWITCH/CONTROL STATION
CT CURRENT TRANSFORMER
CU COPPER
CWS CONDUIT WALL SEAL
DC DIRECT CURRENT
DIA DIAMETER
DMU DIGITAL METERING UNIT
DN DOWN
EC EMPTY CONDUIT
ELEC ELECTRICAL
ELEV ELEVATION
EM EMERGENCY
ENCL ENCLOSURE OR ENCLOSED
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EX EXISTING
FO FIBER OPTIC
FU FUSE
GCP GENERATOR CONTROL PANEL
GEN GENERATOR
G, GND GROUND
GFI GROUND FAULT INTERRUPTER
GRS GALVANIZED RIGID STEEL
HACR HEATING & AIR CONDITIONING RATED
HH HANDHOLE
HT HEIGHT
HID HIGH INTENSITY DISCHARGE
HP HORSEPOWER
HZ HERTZ
ID IDENTIFICATION
INSTR INSTRUMENT
K KILO (PREFIX)
kcmil 1000 CIRCULAR MILS
KVA KILOVOLT AMPERES
KW KILOWATTS
LA LIGHTNING ARRESTER
LTG LIGHTING
LP LIGHTING PANEL
LV LOW VOLTAGE
FB
GROUND SYSTEM GRID OR LOOP, 36" BELOW FINISHED GRADE UNLESS
OTHERWISE NOTED.
DUPLEX RECEPTACLE, 20A, 120V, 2P, 3W
MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED
* GFCI - GROUND FAULT CIRCUIT INTERRUPTER TYPE
WP - WEATHERPROOF
XP - EXPLOSION PROOF
T - TRANSIENT VOLTAGE SURGE SUPPRESSOR
4 - CIRCUIT NUMBER
+*" - MOUNTING HEIGHT AFF
DUPLEX RECEPTACLE, 20A, 120V, 2P, 3W
MOUNTED ABOVE COUNTER-TOP OR 42" AFF UNLESS OTHERWISE NOTED
* NOTATIONS SAME AS ABOVE
WALL MOUNTED EXIT SIGN, NOTATIONS SAME AS ABOVE. WHEN USED,
ARROW INDICATES DIRECTION OF EGRESS. FILLED QUADRANT REPRESENTS
FACE SIDE OF SIGN.
COMBINATION BATTERY UNIT AND EXIT SIGN. FILLED QUADRANT
REPRESENTS FACE SIDE OF SIGN.
DENOTES A QUANTITY OF TWO (2) 3-INCH CONDUITS EACH CONTAINING
THREE NO. 3/0 AWG CONDUCTORS AND 1 NO. 2 AWG GROUND CONDUCTOR.
DENOTES A QUANTITY OF TWO INSTRUMENT CABLES. EACH CABLE TO
CONSIST OF TWO NO. 16 AWG CONDUCTORS TWISTED TOGETHER AND
COVERED WITH A METALLIC SHIELD AND AN OVERALL PROTECTIVE JACKET.
REFER TO THE SPECIFICATIONS FOR THE EXACT CABLE TO BE PROVIDED.
HOME RUN TO DESIGNATED EQUIPMENT. BRANCH CIRCUIT CONDUIT WITH 2
NO. 12 AWG BRANCH CIRCUIT CONDUCTORS AND 1 NO. 12 AWG GROUND
CONDUCTOR UNLESS OTHERWISE NOTED. NUMBER OF ARROWS INDICATE
NUMBER OF CIRCUITS. FOR MINIMUM SIZE CONDUIT PERMITTED REFER TO
THE SPECIFICATIONS.
CROSS HATCH INDICATES LIGHTING FIXTURE THAT IS UNSWITCHED AND
SHALL REMAIN ON AT ALL TIMES. NOTATIONS SAME AS ABOVE.
DOUBLE POLE SWITCH
"OS" INDICATES PROGRAMMABLE OCCUPANCY SENSOR CAPABLE OF
INBOARD/OUTBOARD SWITCHING
SINGLE POLE SWITCH
"OS" INDICATES A PASSIVE INFRARED OCCUPANCY SENSOR
HORSEPOWER RATED TOGGLE SWITCH. VOLTAGE AND CURRENT
COORDINATED WITH UNIT BEING POWERED.
DESCRIPTIONSYMBOL
LIGHTING FIXTURE
"A" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)
"b" - CONTROLLED BY SWITCH "b"
"3" - CIRCUIT NUMBER
LIGHTING FIXTURE, NOTATIONS SAME AS ABOVE
WALL MOUNTED TYPE LIGHTING FIXTURE, NOTATIONS SAME AS ABOVE
EMERGENCY LIGHTING BATTERY UNIT WITH TWO LAMP HEADS
"EM" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)
"3" - SUPERVISORY CIRCUIT
* - FIXTURE TAG #
REMOTE EMERGENCY ADJUSTABLE WALL LIGHTING FIXTURE WITH TWO LAMP
HEADS
"R-2" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)
* - HOME RUN TO BATTERY UNIT INDICATED. CONDUIT
SHALL BE 3/4" AND CONTAIN (2) NO. 12 AWG BRANCH
CIRCUIT CONDUCTORS AND (1) NO. 12 AWG GROUND
CONDUCTOR UNLESS OTHERWISE INDICATED.
REMOTE EMERGENCY CEILING LIGHTING FIXTURE.
"RH-3" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)
"3" - SUPERVISORY CIRCUIT
* - HOME RUN TO BATTERY UNIT INDICATED. CONDUIT
SHALL BE 3/4" AND CONTAIN 2 NO. 12 AWG BRANCH
CIRCUIT CONDUCTORS AND 1 NO. 12 AWG GROUND
CONDUCTOR UNLESS OTHERWISE INDICATED.
CONDUIT CONCEALED IN WALL, IN SLAB ABOVE, OR ABOVE CEILING.
CONDUIT RUN EXPOSED. RUN PARALLEL OR PERPENDICULAR TO STRUCTURE
OR WALL.
CONDUIT STUBBED OUT AND CAPPED
SAME AS ABOVE EXCEPT CABLE TO CONSIST OF THREE NO. 16 AWG
CONDUCTORS TWISTED, SHIELDED AND COVERED WITH AN OVERALL
PROTECTIVE JACKET. REFER TO THE SPECIFICATIONS FOR THE EXACT CABLE
TO BE PROVIDED.
POLE MOUNTED AREA TYPE LIGHTING FIXTURE, NOTATIONS SAME AS ABOVE
CEILING MOUNTED EXIT SIGN, NOTATIONS SAME AS ABOVE. WHEN USED,
ARROW INDICATES DIRECTION OF EGRESS. FILLED QUADRANT REPRESENTS
FACE SIDE OF SIGN. (DOUBLE FACE DOUBLE CHEVRONS SHOWN)
CONDUIT CONCEALED IN OR BELOW FLOOR OR UNDERGROUND.
CONCRETE ENCASED DUCTBANK. WIDTH VARIES, SEE DUCTBANK
SECTION/DETAILS FOR REQUIREMENTS AND WIDTH
THREE 4-INCH CONDUITS
FLEXIBLE METAL CONDUIT "WHIP" (3/4"C., 2#12, 1#12G UNLESS OTHERWISE
NOTED) FOR LIQUID TIGHT MOTOR CONNECTIONS
'X' INDICATES CONDUIT SEAL FITTING IN OTHER THAN CODE REQUIRED
LOCATIONS.
INDICATES MOTOR STARTER AND/OR MOTOR CONTROL EQUIPMENT WITHIN
THE ENCLOSURE.
DESCRIPTIONSYMBOL
SINGLE POLE SWITCH "a" INDICATES FIXTURES CONTROLLED.
DOUBLE POLE SWITCH "a" INDICATES FIXTURES CONTROLLED.
THREE WAY SWITCH "c" INDICATES FIXTURES CONTROLLED.
FOUR WAY SWITCH "a" INDICATES FIXTURES CONTROLLED.
DIMMER SWITCH "a" INDICATES FIXTURES CONTROLLED
LIGHTING CONTACTOR WITH NUMBER OF POLES AS INDICATED
TIME SWITCH
INDICATES ALL LIGHTING FIXTURES WITHIN THE ROOM OR AREA IN WHICH
THIS NOTATION APPEARS SHALL BE TYPE "A" UNLESS OTHERWISE NOTED.
SEE LIGHTING FIXTURE SCHEDULE FOR TYPES
LIGHTING PANELBOARD (LP-#)
SHOWN ON PLAN PER ACTUAL PANEL DIMENSIONS
POWER PANELBOARD (PP-#) OR DISTRIBUTION PANELBOARD (DP-#) SHOWN
ON PLAN PER ACTUAL PANEL DIMENSIONS
PUSH BUTTON STATION
SPECIAL PURPOSE RECEPTACLE
* - VOLT RATING
"3" - NUMBER OF POLES
"60" - AMPERE RATING
"4W" - 4 WIRES IN ADDITION TO GROUND
MULTI-OUTLET ASSEMBLY, SYMBOL DENOTES RECEPTACLE TYPE
FLUSH FLOOR OUTLET BOX WITH TYPE OUTLET INDICATED
UNDER FLOOR DUCT SYSTEM WITH TYPE OUTLETS INDICATED
THREE CELL UNDER FLOOR DUCT SYSTEM JUNCTION BOX
JUNCTION BOX
PULL BOX
TERMINAL CABINET
OCCUPANCY SENSOR
PHOTOCELL
EMERGENCY EYEWASH/SHOWER ALARM STATION WITH FLOW SWITCH(ES)
GLASS BREAK DETECTOR
PAN, TILT, ZOOM CAMERA LENS CONTROLS
CLOSED CIRCUIT TV CAMERA
SECURITY ALARM MOTION DETECTOR
SECURITY ALARM WINDOW SWITCH
SECURITY SYSTEM CARD ACCESS READER
SECURITY ALARM KEY PAD
SECURITY ALARM DOOR SWITCH
SECURITY ALARM CONTROL PANEL
"C" - DATA INPUT/OUTPUT CABLE OUTLET
"P" - PROCESS COMPUTER SYSTEM (CAT6 RJ-45 JACK)
TELEPHONE CABINET OR BACKBOARD AS NOTED
PAGING SPEAKER AMPLIFIER ASSEMBLY
REMOTE WALL MOUNTED VOLUME CONTROL FOR CEILING SPEAKER, MOUNT
UP 5'-0"
PAGING SPEAKER, SURFACE MOUNTED CEILING TYPE
PAGING SPEAKER, FLUSH MOUNTED CEILING TYPE
PAGING SPEAKER, WALL MOUNTED, BI-DIRECTIONAL, HORN TYPE
W = WIDE ANGLE TYPE
PAGING SPEAKER, WALL MOUNTED
H = HORN TYPE
W = WIDE ANGLE TYPE
PAGE/PARTY TELEPHONE OUTLET FOR WALL TYPE HANDSET, MOUNT UP 4'-6"
PAGE/PARTY TELEPHONE OUTLET FOR DESK TYPE HANDSET
TELEPHONE OUTLET FOR WALL TYPE HANDSET (MOUNT UP 4'-6")
K = KEY SYSTEM
TELEPHONE OUTLET FOR DESK TYPE HANDSET
K = KEY SYSTEM
INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED
WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL BE OF
NEMA 4X CONSTRUCTION (OR CORROSION RESISTANT CONSTRUCTION
SUITABLE FOR USE IN A WET LOCATION WHERE NEMA STANDARDS DO NOT
APPLY) UNLESS OTHERWISE NOTED.
INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED
WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL BE OF
NEMA 4X CONSTRUCTION (OR GASKETED AND SUITABLE FOR USE IN A WET
LOCATION WHERE NEMA STANDARDS DO NOT APPLY) UNLESS OTHERWISE
NOTED.
INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED
WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL BE OF
NEMA 12 CONSTRUCTION (OR GASKETED AND SUITABLE FOR USE IN A WET
LOCATION WHERE NEMA STANDARDS DO NOT APPLY) UNLESS OTHERWISE
NOTED.
FIRE ALARM HEAT DETECTOR 135 FIXED TEMPERATURE UNLESS OTHERWISE
NOTED.
"200" - 200 FIXED TEMPERATURE
"R" - FIXED TEMPERATURE RATE-OF-RISE TYPE
FIRE ALARM SMOKE DETECTOR PHOTOELECTRIC TYPE UNLESS OTHERWISE
NOTED.
"I" - IONIZATION TYPE.
FIRE ALARM DUCT SMOKE DETECTOR
FIRE ALARM CONTROL PANEL
FIRE ALARM VENTILATION PANEL WITH GRAPHIC PANEL
REMOTE FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM MASTER BOX
FIRE ALARM HORN, MOUNT UP 7'-6"
SPRINKLER VALVE SUPERVISORY SWITCH
SPRINKLER FLOW ALARM SWITCH
FIRE ALARM BELL
WEATHERPROOF HI-INTENSITY FIRE ALARM STROBE LIGHT WITH HORN
PASSIVE INFRARED DETECTOR
SMOKE BEAM DETECTOR (RECEIVER)
SMOKE BEAM DETECTOR (TRANSMITTER)
FIRE ALARM SMOKE DETECTOR REMOTE INDICATOR AND TEST SWITCH
OR
A 3 b
A 3 b
A 3
A 3 b
3A
3A
EM
BU-1(*)
R-2
A 3
A
A 3
BU-1(*)E
RH-3
(2) 3"C., 3#3/0, 1#2G
2-2/C#16 SH
2-3/C#16 SH
(3) 4"C.
C 3
TYPE A
TC
P
J OR J
OS
PC
DESCRIPTIONSYMBOL
INDICATED EQUIPMENT AND MATERIALS TO BE DEMOLISHED
4W
DUST
DAMP
WET
CORROSIVE
OR
EXOTHERMIC WELD CONNECTION
3/4" x 10'-0" GROUND ROD. UNLESS SPECIFIED OTHERWISE.
GROUND ROD TEST WELL STATION
(SEE DETAIL SHEET FOR REQUIREMENTS)
COMMUNICATION SYSTEMS
K
K
S H W
S W
S
S
VC
A
TM
SECURITY SYSTEMS
K
SACP
DS
R
WS
CCTV
PTZ
GB
FIRE ALARM SYSTEMS
FACP
FV
FA
VSS
SFS
PIR
F
F
H R
I
D
DESCRIPTIONSYMBOL
F
R
T a a c a D
OS
OS
M a
POLE MOUNTED ROADWAY TYPE LIGHTING FIXTURE, NOTATIONS SAME AS
ABOVE
SHADED AREA INDICATES LIGHTING FIXTURE THAT IS EQUIPPED WITH
EMERGENCY BACKUP POWER SOURCE. NOTATIONS SAME AS ABOVE.OR
A 3 b b
3A
INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED
WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL
CONFORM TO N.E.C. REQUIREMENTS FOR THE HAZARDOUS AREA
CLASSIFICATION SHOWN.
CLASS I, DIV. 1
GROUP D
FIRE ALARM STROBE, MOUNT UP 6'-8"
15 = CANDELA RATING
FIRE ALARM HORN AND STROBE LIGHT COMBINATION, MOUNT UP 6'-8"
15 = CANDELA RATING
FIRE ALARM MANUAL PULL STATION, MOUNT UP 4'-0"F
F
F
LIGHTING CONTACTOR PANELBOARD (LCP-#)
SHOWN ON PLAN PER ACTUAL PANEL DIMENSIONS
A 3
ESA
C
OR
1 = MASTER, 2 = REMOTE
GAS DETECTOR/VENTILATION FAILURE ALARM,
# INDICATES TYPE OF UNIT.GD/VF
GB GAS DETECTION/VENTILATION FAILURE WEATHERPROOF DUAL-LITE BEACON
MOUNT TOP OF DEVICE UP 6'-8" A.F.F.
G
MOUNT TOP OF DEVICE UP 6'-8" A.F.F.
GAS DETECTION/VENTILATION FAILURE HORN/STROBE
GAS DETECTION/VENTILATION FAILURE HORN,
G MOUNT TOP OF DEVICE UP 6'-8" A.F.F.
G GAS DETECTION/VENTILATION FAILURE STROBE,
MOUNT TOP OF DEVICE UP 6'-8" A.F.F.
'X' INDICATES EXPLOSION PROOF CONDUIT SEAL FITTING.
DUPLEX RECEPTACLE - ONE RECEPTACLE CONTROLLED
MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED
* NOTATIONS SAME AS ABOVE
UON UNLESS OTHERWISE NOTED
EXPLOSIONPROOF (CLASS 1, DIVISION I) REEL LIGHT - 200' SOOW CORD
A3
4 +*"
DOUBLE DUPLEX RECEPTACLE - TWO CONTROLLED RECEPTACLES
MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED
* NOTATIONS SAME AS ABOVE
DOUBLE DUPLEX RECEPTACLE, 20A, 120V, 2P, 3W
MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED
* NOTATIONS SAME AS ABOVE
PLUG LOAD CONTROLLER
R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
/2
0/
IS
SU
E
D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 3 5 7 9
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10
F
D
B
B-
SU
BM
IT
TA
L
- I
SS
U
E
FO
R C
O N
ST
R
U C
TI
O
N
FL
O
R
ID
A
AI
R N
AT
IO
N
AL
G U
AR
D
JA
C
KS
O
N
VI
LL
E
AN
G
B, F
LO
R
ID
A
P ar kw ay
L an e Su ite
Pe ac ht re e
C or ne rs
, G A
LI
C
EN
SE
N
U M
BE
R
S:
AR
C H
IT
EC
TU
R
E:
A
A2
EN
G
IN
EE
R
IN
G
C oA N o.
So ut ha ll
La ne
, S ui te
M ai tla nd , F
L
Te l:
(4
) 6
-2
FL
A C
O A
N o.
E B-
5t h
FI
G H
TE
R
W
IN
G J
AC
KS
O N
VI
LL
E, F
L, F-
R
EP
AI
R
H
AN
G
AR
, B
LD
G
LS
G
A2
E-006
EX
IS
TI
N
G D
EM
O
LI
TI
O N
O N
E
LI
N E
PO
W
ER
D
IA
G
R
AM
O . C
R U
Z
R . R
U C
K
B.
P
ET
TI
FO
R
D
S.
P
ER
R
Y
AM
EN
D M
EN
T
#2 3/
8/
XR
EF
s:
[2
9_
AN
SI
D _2
2x
_B or de r_
U
SA
es
La st s av ed b y:
R
U C
KR
M
T im e:
/3 /2
9:
:3
AM
pw cd m sm ith -a z0 2-pw .b en tle y.
co m :p w _p l1 \2
8\
\0
D es ig n
Se rv ic es
N M
_5
\0
El ec tri ca l\1
BI
M
_C
AD
D \X
XX
X#
#E
6.
dw g
R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
/2
0/
IS
SU
E
D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 3 5 7 9
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10
F
D
B
B-
SU
BM
IT
TA
L
- I
SS
U
E
FO
R C
O N
ST
R
U C
TI
O
N
FL
O
R
ID
A
AI
R N
AT
IO
N
AL
G U
AR
D
JA
C
KS
O
N
VI
LL
E
AN
G
B, F
LO
R
ID
A
P ar kw ay
L an e Su ite
Pe ac ht re e
C or ne rs
, G A
LI
C
EN
SE
N
U M
BE
R
S:
AR
C H
IT
EC
TU
R
E:
A
A2
EN
G
IN
EE
R
IN
G
C oA N o.
So ut ha ll
La ne
, S ui te
M ai tla nd , F
L
Te l:
(4
) 6
-2
FL
A C
O A
N o.
E B-
5t h
FI
G H
TE
R
W
IN
G J
AC
KS
O N
VI
LL
E, F
L, F-
R
EP
AI
R
H
AN
G
AR
, B
LD
G
LS
G
A2
E-007
O N
E
LI
N E
PO
W
ER
D
IA
G
R
AM
O . C
R U
Z
R . R
U C
K
B.
P
ET
TI
FO
R
D
S.
P
ER
R
Y
AM
EN
D M
EN
T
#2 3/
8/
XR
EF
s:
[2
9_
AN
SI
D _2
2x
_B or de r_
U
SA
es
La st s av ed b y:
R
U C
KR
M
T im e:
/3 /2
9:
:1
AM
pw cd m sm ith -a z0 2-pw .b en tle y.
co m :p w _p l1 \2
8\
\0
D es ig n
Se rv ic es
N M
_5
\0
El ec tri ca l\1
BI
M
_C
AD
D \X
XX
X#
#E
7.
dw g
42KAIC
ON/OFF
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
G
A
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:0
A
M
E-008
L
IG
H T
IN
G
C O
N T
R O
L R
IS
E
R D
IA
G
R A
M S
I
O C
R U
Z
R R
U C
K
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
DEVICE LEGEND
EQPMT ID. DEVICE TYPE
OS OCCUPANCY SENSOR
DAYLIGHT SENSOR
POWER PACK/LIGHTING RELAY (0-10V) DIMMING
LINE VOLTAGE MULTI-WAY SWITCH
ON/OFF - RAISE LOWER CONTROL
LINE VOLTAGE MULTI-WAY SWITCH
ON/OFF CONTROL
LINE OR LOW VOLTAGE SWITCH
ON/OFF - RAISE LOWER CONTROL
LINE VOLTAGE SWITCH
ON/OFF CONTROL
EMERGENCY POWER PACK/LIGHTING RELAY
(0-10V) DIMMING
EMERGENCY POWER PACK/LIGHTING RELAY
POWER PACK/ LIGHTING RELAY
PLUG LOAD CONTROL POWER PACK/LIGHTING RELAY
NOTES:
RISER DIAGRAMS SHOWN ARE TYPICALS AND ILLUSTRATE
CONCEPTUAL CONTROL SEQUENCE. ACTUAL WIRING IS
MANUFACTURER DEPENDENT. REFER TO PLAN DRAWINGS FOR
QUANTITY OF DEVICES AND LOCATIONS. ADDITIONAL DEVICES MAY BE
REQUIRED TO IMPLEMENT CONTROL FUNCTIONS. PROVIDE ALL
EQUIPMENT INCLUSIVE OF HEADEND EQUIPMENT REQUIRED FOR
FULL LIGHTING SYSTEM OPERATION. CONSULT MANUFACTURER FOR
FINAL WIRING DIAGRAMS AND SUBMIT TO ENGINEER FOR APPROVAL
AS A SHOP DRAWING.
CONTRACTOR SHALL SUBMIT FULL DIAGRAMS FOR ALL LIGHTING
CONTROL SPACES AS A SHOP DRAWING.
1.
RISER DIAGRAM
NTS
RISER DIAGRAM
ON/OFF/0-10V DIMMING (RAISE/LOWER)
NTS
H
LOAD
N
WHITE W/ BLUE STRIPE
CAP OFF
WHITE W/ BLUE STRIPE
N H
BLK-120V
ORN-277V
RED
WHITE
BLACK
BLUE
BLUE
BLK/ORG
WHITE
LOAD
BLACK
WHITE
BLACK
WHITE
BLACK (COMMON)
YELLOW/BLACK
YELLOW
BLACK
WHITE
BLACK
WHITE
RED
RED
RED 12-24V POWER
RED
RED
WHITE
AUTO ON/OFF W/ THREE WAY
SWITCHING AND 0-10V DIMMING
LIGHTING CONTROLS
ROOM NO. DESCRIPTION
110 MECH/ELEC ROOM
ELECTRICAL
BLDG-1001
114 MECH/ELEC ROOM
ELECTRICAL
127B MECH ROOM
ELECTRICAL ROOM139A
182 MECH ROOM
LIGHTING CONTROLS
ROOM NO.
106A STORAGE
BLDG-1001
106 EJECTION SEAT STORAGE
EGRESS OFFICE107
DESCRIPTION
RISER DIAGRAM
NTS
AUTO ON/OFF W/ MULTI WAY
SWITCHING AND 0-10V DIMMING
LIGHTING CONTROLS
ROOM NO.
BLDG-1001
DESCRIPTION
116 FLIGHT LINE LO
127 READY ROOM
134 ELEVATOR ELECTRICAL
DS
PPd
EPPd
EPP
PP
PL
SWd
SWa
SWb
SWc
PHOTOCELLPC
113A CORRIDOR
RISER DIAGRAM
NTS
HANGAR BAY
RISER DIAGRAM
NTS
ON/OFF/0-10V DIMMING (RAISE/LOWER) W/
OCCUPANCY SENSOR
ROOM NO. DESCRIPTION
107A EJECTION SEAT SHOP
103 WHEEL & TIRE SHOP
CANOPY SHOP108
COMM
VESTIBULE OR CORRIDOR
121 N. ENTRY
123B OFFICE
OS/DS
RED
WHITE
BLACK
BLACK
RED
WHITE
BLACK
WHITE
RED
WHITE
BLK/ORG
BLUE
BLUE
BLACK
RED
BLACK
RED
WHITE
BLACK
WHITE
RED
BLACK
RED
WHITE
WHITE
RED
BLACK
WHITE
WHITE
RED
BLACK
BLACK
WHITE
RED
WHITE W/ BLUE STRIPE
VIOLET
(DIMMING 0-10VDC OUTPUT)
TO VIOLET WIRE ON DIMMING BALLAST
GREY WIRE FROM BALLAST
IS CONNECTED TO THE BLACK WIRE
ON THE LOW VOLTAGE SIDE OF
THE POWER PACK GREY
BLUE
BLUE
BLK/ORG
WHITE
BLUE
BLUE
BLK/ORG
WHITE
GREY
GREY WIRE FROM BALLAST
IS CONNECTED TO THE BLACK WIRE
ON THE LOW VOLTAGE SIDE OF
THE POWER PACK
WHITE W/ BLUE STRIPE
VIOLET
(DIMMING 0-10VDC OUTPUT)
WHITE W/ BLUE STRIPE
VIOLET
(DIMMING 0-10VDC OUTPUT)
N H
TO VIOLET WIRE ON DIMMING BALLAST
RED
WHITE
BLACK
BLK-120V
ORN-277V
BLK-120V
ORN-277V
BLK-120
V
ORN-277
V
LOAD
LOAD
LOAD
NETWORK
CONTROLLER
ADVANCED W/
HINGED
LOCKING DOOR
SIMILAR TO
LLNC-A-HLD BY
LIGHT LEEDER
DS
NORTH HANGAR
BAY LIGHTING
CONTROLLER
SIMILAR TO
LL-EVO
BY LIGHTLEEDER
P P d E
P P d
WS WALLSTATION WITH SETTINGS: ON/OFF, ALL ZONES,
ZONE 1, ZONE 2, ZONE 3, RAISE LOWER(30-70%)
ALL ZONES
NH-'A'
NH-'B'
NH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
WS WS WS WS
ALL ZONES
NH-'A'
NH-'B'
NH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
ALL ZONES
NH-'A'
NH-'B'
NH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
ALL ZONES
NH-'A'
NH-'B'
NH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
ALL ZONES
SH-'A'
SH-'B'
SH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
WS WS WS WS
ALL ZONES
SH-'A'
SH-'B'
SH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
ALL ZONES
SH-'A'
SH-'B'
SH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
ALL ZONES
SH-'A'
SH-'B'
SH-'C'
DIM/AUTO
RAISE/
LOWER
ON/OFF
NH-'A'
NH-'B'
NH-'C'
CAT-6 DATA CABLE FOR NETWORK SYSTEM
CAT-6 DATA CABLE FOR BUS OF LOCAL CONTROLLER
CAT-6 DATA CABLE FOR BUS OF LOCAL CONTROLLER
SOUTH HANGAR
BAY LIGHTING
CONTROLLER
SIMILAR TO
LL-EVO
BY LIGHTLEEDER
P P
E P
P
NOTES:
QUANTITY OF EACH TYPE OF RELAY, ADDITIONAL POWER SUPPLIES,
NETWORK EQUIPMENT, CONTROL PANELS, AND ANCILLARY
EQUIPMENT SHALL BE AS REQUIRED TO IMPLEMENT THE LIGHTING
CONTROL STRATEGY.
FIELD LOCATE LIGHTING CONTROL PANELS IN ELECTRICAL ROOMS AS
REQUIRED FOR SYSTEM FUNCTIONALITY.
PROVIDE SURGE PROTECTION DEVICES WITH EACH CONTROL PANEL
PROVIDE A CENTRAL INVERTER FOR EMERGENCY POWER TO
HANGAR LIGHTS INDICATED AS EMERGENCY FIXTURES.
1.
2.
3.
P P d E
P P d P
P E
P P
OS
SWc
H N
LOAD
WHITE
BLACK BLACK
B L A
C K
VIOLET & GRAY (0-10V)
DS
DS
OS
NH-'A'
OS
NH-'B'
OS
NH-'C'
DS
NH-'A'
NH-'B'
NH-'C'
DS
DS
OS
NH-'A'
OS
NH-'B'
OS
NH-'C'
OS
DS (WHERE APPLICABLE)
ON/OFF OR
2.
SWc OR SWd (AS REQUIRED BY APPLICATION)
SWa
OS
SWc
4.
BLACK BLACK
GND
VIOLET
GRAY
ROOM NO. DESCRIPTION
104 W&T STORAGE
BLDG-1001
LOCKERS
115 OFFICE
118 EQUIP./HAZMAT STORAGE
118A COLLATERAL STORAGE
ALL INDIVIDUAL
OFFICES UNLESS
OTHERWISE NOTED
OFFICE
LIGHTING CONTROLS
COLLATERAL STORAGE118A
ROOM NO. DESCRIPTION
SWa
SWa
SWa
116A VESTIBULE
APG SUPERVISORS124
ALL CORRIDORS AND
VESTIBULES UNLESS
OTHERWISE NOTED
ALL COMM CLOSETS
UNLESS OTHERWISE
NOTED.
125 TRAINING
RADIO DISPATCH126AALL LOCKER ROOMS
UNLESS OTHERWISE
NOTED
ALL RESTROOMS
UNLESS OTHERWISE
NOTED (ADD. OS'S
MAY BE REQUIRED)
RESTROOMS
BREAKROOM135
159 AVIONICS
ELECTRICAL ROOM163
163 LOCKHEED/PMA STORAGE
169 OVERFLOW STORAGE
176 SUPPORT SHOP
STORAGE171
BREAKROOM170
180 SHOP
181 CORRIDOR
184 BATTERY (CHARGE)
186 BATTERY (STORAGE)
C h a n g e
/1
/2
A m e n d m e n t
/8
/2
PPd
PPd
PPd
NOTES:
IN SPACES WHERE DIFFERENT TYPES OF LIGHTS ARE INSTALLED,
SWITCHES MUST HAVE DISTINCT BUTTONS TO CONTROL LIGHT
GROUPS INDEPENDENTLY.
QUANTITY OF POWER PACKS SHALL BE AS REQUIRED TO CONTROL
LIGHTING WITHIN THE ROOM/AREA.
1.
2.
NOTES:
IN SPACES WHERE DIFFERENT TYPES OF LIGHTS ARE INSTALLED,
SWITCHES MUST HAVE DISTINCT BUTTONS TO CONTROL LIGHT
GROUPS INDEPENDENTLY.
QUANTITY OF POWER PACKS SHALL BE AS REQUIRED TO CONTROL
LIGHTING WITHIN THE ROOM/AREA. QUANTITY OF OS SHALL BE AS
INDICATED ON THE PLANS.
1.
2.
OS
B L A
C K
PPd
NOTES:
IN SPACES WHERE DIFFERENT TYPES OF LIGHTS ARE INSTALLED,
SWITCHES MUST HAVE DISTINCT BUTTONS TO CONTROL LIGHT
GROUPS INDEPENDENTLY.
QUANTITY OF POWER PACKS SHALL BE AS REQUIRED TO CONTROL
LIGHTING WITHIN THE ROOM/AREA. QUANTITY OF OS SHALL BE AS
INDICATED ON THE PLANS.
1.
2.
M
M
MOD
M O
D
STORAGE
106A
EJECTION SEAT
STORAGE
EGRESS OFFICE
OFFICE
MECH
CANOPY SHOP
WOMEN LOCKERS
FLIGHT LINE LO
OFFICE
MECH
COMM
117A
COLLATERAL
STORAGE
118A
EQUIP./HAZMAT
STORAGE
ELEC
N. ENTRY
ELEC
OFFICE
123B
OFFICE
N. VESTIBULE
OFFICE
123C
OFFICE
123A
APG
SUPERVISORS
WHEEL & TIRE
SHOP
W&T STORAGE
CORRIDOR
113A
VESTIBULE
116A
EJECTION SEAT
SHOP
107A
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
+42" +42"
PB1A- 7
PB1A- 7
PB1A- 7
PB1A- 7
PB1A- 7
PB1A- 15 PB1A- 15
PB1A- 15PB1A- 15
PB1A- 8
PB1A- 8
PB1A- 8
PB1A- 8
P B
A
PB1A- 2
PB1A- 2
P B
A
PB1A- 18
PB1A- 18
PB1A- 6
PB1A- 14
PB1A- 4
PB1A- 4
PB1A- 4
PB1A- 4
PB1A- 17
PB1A- 17 PB1A- 17
PB1A- 17PB1A- 17
P B
A
P B
A
PB1A- 19
PB1A- 12
PB1A- 35
PB1A- 20
PB1A- 20
PB1A- 12
P B
A
PB1A- 27
PB1A- 11
PB1A- 11
P B
A
P B
A
PB1A- 12
P B
A
P B
A
P B
A
PB1A- 5
1E- 8
LB1- 8
LB1- 21
LB1- 21
LB1- 21
LB1- 21
LB1- 18
LB1- 18
LB1- 4
LB1- 4
LB1- 4
LB1- 17LB1- 17
LB1- 17
LB1- 25
LB1- 25
LB1- 25
LB1- 25
PB1A- 12
PB1A- 10
PB1A- 10
PB1A- 10
PB1A- 10
PB1A- 29
PB1A- 5
PB1A- 29
1E- 8
LB1- 8
PB1A- 1
LB1- 18
LB1- 17
P B
A
+72"
PB1A- 6 +72"
LB1- 18
LB1- 11
L B
WP/GFCI
W
P /G
F C
I
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
XP
1PB1A- 3
PB1- 24
SEAT TRAILER
SEAT
TRAILER
CANOPY TRAILER
CANOPY TRAILER
XP
XP
PORTABLE
CRANE
PANEL
RACKS
CU-1
DOAS-1
CU-2
AHU-2
EF-1
M
DAC-1
DCU-1
AHU-1
IWH-1
IWH-2
VAV-3-1
NITROGEN
GENERATOR
DS-PWCONV 1
P B
A
PB1A- 17
MEN LOCKERS
CORRIDOR
113A
G F
C I
NORTH HANGAR
BAY
+48"+20"
+48"
PB1A- 16
LB1- 11
PB1A- 30
PB1A- 9
LB1A- 8
PB1A- 23
HB1B- 20,22,24
PANEL 1L
PANEL 1H
1E
HB1A
LB1A
LB1
PB1A
PB1A- 5
HB1B- 1
PB1B- 6,8
PB1B
PB1B- 1,3
IWH-3
IWH-4
HB1B- 9,11,13
PB1A- 21
PB1B- 2,4
HB1B- 21,23,25
HB1B
HB1B- 8,10,12
HB1B- 3,5,7
PB1A- 18
PB1B- 9,11
GFCI
GFCI
G F
C I G
F C
I
WP/GFCI
GFCI
WP/GFCI
W P
/G F
C I
LB1- 11
M
M
ROLLUP DOOR -106 OPERATOR
ROLLUP DOOR -107 OPERATOR
HB1B- 38,40,42
+42"
+42"
HB1B- 32,34,36
PB1A- 28
PB1A- 31
+42"
HB1A- 31,33,35
PB1B- 5,7
60A, 2P
LB1- 27
EWH-1
PB1B- 10
PB1B- 12
PB1B- 13
A
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:1
A
M
E-010
E L E
C T
R
IC
A L P
L A
N
A R
E A
A
M S
M
IT
H
M S
M
IT
H
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
1/8" = 1'-0"1
ELECTRICAL PLAN - AREA A
KEY NOTES:
1. COORDINATE WITH HVAC MECHANICAL
CONTRACTOR FOR INSTALLATION AND POWERING
OF HVAC EQUIPMENT FURNISHED BY THE
MECHANICAL CONTRACTOR. WHERE M-SHEETS DO
NOT INDICATE THE PROVISION OF SWITCHES BY
THE MECHANICAL CONTRACTOR THEY SHALL BE
PROVIDED BY THE ELECTRICAL CONTRACTOR.
2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL
BE GFCI PER NEC 210.8 REQUIREMENTS.
3. WHERE THE STANDARD FUSED SWITCH RATING IS
TOO LARGE FOR ACCOMODATING THE FUSE SIZE
INDICATED , PROVIDE A FUSE ADAPTER KIT.
SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND
APPROVAL WITH FUSES AND SWITCHES.
NOTES:
2-EXPLOSION PROOF RECEPTACLES, COLUMN
MOUNTED. THE BASIS OF DESIGN IS KILLARK
UGR8-20231QW 20A CLASS 1, DIVISION 1.
480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE
4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR
SUPPORT EQUIPMENT.
200A, 3P, 4W BUSDUCT PLUG-IN FUSED DISCONNECT
SWITCH (150 AF) .
REPLACE EXISTING 480/277V 800A BUSWAY "BDTN"
WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW
PLUG IN UNITS, END BOXES, AND ACCESSORIES.
POWER CONVERTER:
INPUT: 480V, 3PH, 4W+G, 90KVA
OUTPUT: 270VDC, 400HZ, AND 28VDC
CABLE HANDLER REEL
ROLLUP DOOR: WIRE PER MANUFACTURER'S
REQUIREMENTS COORDINATE OPERATOR LOCATION
AND MOTOR CONNECTION WITH INSTALLATION OF
DOOR AS REQUIRED.
60A, 240V or 600V RATED, 2-POLE SWITCH
30A, 600V RATED, 3P, 3W+G, NEMA 1 DS
30AS, 15AF, 600V RATED, 3P, 3W+G, NEMA 1 DS
60AS, 35AF 600V RATED, 3P, 3W+G, NEMA 3R DS
30AS, 30AF 208 OR 240V RATED, 2P, 2W+G, NEMA 3R DS
INDOOR UNIT WIRED TO OUTDOOR UNIT IN
ACCORDANCE WITH MANUFACTURER REQUIREMENTS.
COORDINATE WITH ARCHITECTURAL AND FIRE ALARM
FOR POWERING DOOR HOLD OPEN DEVICES.
RELOCATE EXISTING EM. SHOWER ALARM CIRCUIT TO
NEW SHOW LOCATION.
60AS, 50AF, 240V RATED, 2P, 2W+G, NEMA 12
60AS, 40AF, 600V RATED, 3P, 3W+G, NEMA 3R
30AS, 25AF, 600V RATED, 3P, 3W+G, NEMA 3R
30AS, 15AF, 600V RATED, 3P, 3W+G, NEMA 3R
SCALE:
4' 8' 16'0
1/8" = 1'-0"
A m e n d m e n t
/8
/2
W
WD
S
FATR
CC
CC
S
FATR
M
M
M
M
M
M
M
M
M
M
M
M
MM
M
M
M
M
M
MOD MOD
READY ROOM
MENS LOCKERS
MECH
127B
OFFICE
CORRIDOR
OFFICE
BREAK ROOM
ELEVATOR
ELECTRICAL
PILOT DEBRIEF
MULTIPURPOSE
ROOM
STAIRS
ELEC
139A
OFFICE
LOCKHEED
LOCKHEED
MEN RESTROOMS
WOMEN
RESTROOMS
CORRIDOR
LACTATION ROOM
ELECTRICAL
MECHANICAL
NORTH HANGAR
BAY
VESTIBULE
127A
CORRIDOR
131A
CORRIDOR
131D
VESTIBULE
143B
VESTIBULE
131B
VESTIBULE
131C
WOMEN LOCKERS
CORRIDOR
143A
LA1
PANEL HA1
+42"
+42"
+42"
+42"
+42"
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
PANEL HC1
PANEL LC1
+42"
LB1A- 11
LB1A- 11
LB1A- 11
LB1- 30
LB1- 30
LB1- 30
L B
LB1- 16
LB1- 37
LB1- 37
LB1- 37
L B
L B
L B
L B
L B
LB1- 39
LB1- 39
LB1- 39
LB1- 10
LB1- 23
LB1- 23
LB1- 23
LB1- 19
LB1- 19
LB1- 12
LB1- 12
LB1- 12
LB1- 13
LB1- 13
LA1- 9
LB1- 12
LB1- 12
LC1- 28
LC1- 28
LC1- 30LC1- 30
LC1- 38
LC1- 1
LC1- 26
LC1- 26
LC1- 25 LC1- 25
LC1- 25
LC1- 24
LC1- 24
LC1- 24
L C
L C
LC1- 34 LC1- 34
LC1- 22
LC1- 22
LC1- 11
LC1- 11
LC1- 7
LC1- 18
LC1- 18
LC1- 1
LC1- 17 LC1- 17
LC1- 17
LC1- 17
LC1- 3LC1- 3 LC1- 21
LC1- 21
LB1- 14
LB1- 14
LB1- 14
LB1- 14
TRAINING
RADIO DISPATCH
126A
OFFICE
VESTIBULE
125A
DIST C MAIN C TIE MAIN B DIST B
SWBD2
120/208
DIST
SWBD2 - 120/208
MAIN SWBD 480/277
LB1- 30
LB1A- 11
LB1- 23
LB1- 19
LB1- 19
LB1- 13 LB1- 13
LB1- 15
LB1- 15
LB1- 7
LB1- 16
LC1- 28
LC1- 28LC1- 28
LC1- 30
LC1- 30
LC1- 30
LC1- 26 LC1- 26
LC1- 26
LC1- 18
LC1- 5 LC1- 24
LC1- 38
LC1- 38
LC1- 1
+42"
LC1- 10
LC1- 2
LC1- 6
LC1- 32
L C
LC1- 19
LC1- 19
LC1- 19
LC1- 17
LC1- 3
LC1- 3LC1- 3
LC1- 21
LC1- 21
LC1- 21
LC1- 9
LB1- 16
LC1- 32
SPD
480V TERMINAL BOX
PANEL 1DP
PANEL EDP1
PANEL EDP2
SWBD MTS
PANEL IQ
PANEL 1C
PANEL 1F
PANEL 1M
PANEL 1P
APRON CONTROL PANEL
PANEL 1J
LC1- 7
LC1- 7
LC1- 11
LC1- 13
L C
L C
+72"
+72"
LB1- 10
+42"
" +72"
GFCI G
F
C I
GFCI
GFCI
GFCI
GFCI
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
XP
XP
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
PB1A- 3 PB1A- 3
PB1 - 25 PB1 - 26
PANEL
RACKS
PANEL
RACKS
LC1- 5
LC1- 5
+72"
+72"
LC1- 19
FACU
PANEL
RACKS
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
VAV-3-7
VAV-3-8
VAV-3-9
VAV-3-6
VAV-3-4
VAV-3-2
VAV-3-3
VAV-3-5 EF-3
VAV-4-8
VAV-4-9
AHU-3
VAV-4-1
VAV-4-6
VAV-4-7
EF
M
AHU-E
AHU-F
DS-PWCONV 2
DS-PWCONV 3
VAV-4-3
VAV-4-4
LC1- 17
+42"
G F
C I
G F
C I
L B
A
L B
A
LC1- 19
T
LC1- 24
LC1- 8
LC1- 4
LC1- 26
LC1- 19
LB1- 3
HB1B- 2,4,6
LA1- 17
LA1- 15
LA1- 23
LA1- 25
LB1A- 15
VAV-4-2
VAV-4-5
CU-7
EF-2
LA1- 34,36
GFCI
GFCI
GFCI
LC1- 2
GFCI
G F
C I
GFCI
IWH-5
IWH-6
HA1B
+42"
+42"
+42"
+42"
HB1B- 27,29,31
HB1A- 37,39,41
LA1- 5
GFCI
LA1- 7
GFCI
GFCI
GFCI
GFCI
LA1- 9 JANITOR
147B
LB1A- 10,12
PANEL 1F- 22,24
60A
LC1- 15
LC1- 16
LB1A- 14
120V
CTRLS
AHU-7
6 6
AKP-1
AKP-1
LA1- 1 LA1- 3
GFCI
B
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:4
A
M
E-011
E L E
C T
R
IC
A L P
L A
N
A R
E A
B
M S
M
IT
H
M S
M
IT
H
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
1/8" = 1'-0"1
ELECTRICAL PLAN - AREA B
SCALE:
4' 8' 16'0
1/8" = 1'-0"
2-EXPLOSION PROOF RECEPTACLES, COLUMN
MOUNTED. THE BASIS OF DESIGN IS KILLARK
UGR8-20231QW 20A CLASS 1, DIVISION 1.
480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE
4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR
SUPPORT EQUIPMENT.
INSTALL TWO QUADRUPLEX RECEPTACLES AT THIS
LOCATION.
NOT USED.
PROVIDE 3 GANG RECESS FLOOR BOX SIMILAR TO
WIREMOLD EVOLUTION SERIES OR APPROVED EQUAL
WITH (1) DUPLEX RECEPTACLE IN 3/4"C, (1) GANG FOR
DATA IN 1-1/4"C, (1) GANG FOR AV IN 1-1/2"C. CONDUITS
SHALL BE ROUTED TO NEAREST WALL AND ABOVE
CEILING. REFER TO ARCHITECTURAL FOR EXACT
LOCATION AND OTHER REQUIREMENTS.
200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH
200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH
RELOCATE PANEL IQ.
REPLACE EXISTING 480/277V 800A BUSWAY "BDTN"
WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW
PLUG IN UNITS, END BOXES, AND ACCESSORIES.
REPLACE EXISTING 480/277V 800A BUSWAY "BDTS"
WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW
PLUG IN UNITS, END BOXES, AND ACCESSORIES. BUS
DUCT AND ACCESSORIES SHALL BE RATED MIN IP54
AND ACCEPTABLE FOR USE IN HUMID ENVIRONMENT.
POWER CONVERTER:
INPUT: 480V, 3PH, 4W+G, 90KVA
OUTPUT: 270VDC, 400HZ, AND 28VDC
CABLE HANDLER REEL
60A, 240V or 600V, 2-POLE SWITCH
30AS, 15AF, 600V, 3P, 3W+G, NEMA 1, DS
30A, 208 OR 240V RATED, 2P, 2W+G, NEMA 1(INDOOR
LOCATION) NEMA 3R (OUTDOOR LOCATION), DS
PROVIDE ADDITIONAL JBOXES, AND SPLICING
HARDWARE, AND APPURTENANCES AS REQUIRED TO
FACILITATE INSTALLATION OF MULTIPLE UNITS OF
EQUIPMENT ON THE SAME CIRCUIT. NOTE THAT
INDIVIDUAL SWITCHES MAY NOT BE RATED FOR FULL
CAPACITY OF LOADS.
30AS, 600V RATED, 3P, 3W+G, NEMA 1 DS
KEY NOTES:
1. COORDINATE WITH HVAC MECHANICAL
CONTRACTOR FOR INSTALLATION AND POWERING
OF HVAC EQUIPMENT FURNISHED BY THE
MECHANICAL CONTRACTOR. WHERE M-SHEETS DO
NOT INDICATE THE PROVISION OF SWITCHES BY
THE MECHANICAL CONTRACTOR THEY SHALL BE
PROVIDED BY THE ELECTRICAL CONTRACTOR.
2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL
BE GFCI PER NEC 210.8 REQUIREMENTS.
3. WHERE THE STANDARD FUSED SWITCH RATING IS
TOO LARGE FOR ACCOMODATING THE FUSE SIZE
INDICATED , PROVIDE A FUSE ADAPTER KIT.
SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND
APPROVAL WITH FUSES AND SWITCHES.
NOTES:
1112 1112
A m e n d m e n t
/8
/2
S
CC C
S
M
MMOD
COMPUTER AREA
SECURE ROOM
OFFICE
OFFICE
BREAK ROOM
AVIONICS
LOCKHEED
WOMEN LOCKERS
MEN LOCKERS
ELEC
S. ENTRY
S. VESTIBULE
SOUTH HANGAR
BAY
VESTIBULE
159A
+42"
+42"
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
T P
T P
T P
T P
T P
T P
TP2- 29
TP2- 34
T P
TP2- 28
TP2- 28
TP2- 28
TP2- 28 TP2- 30
TP2- 30
TP2- 30
TP2- 30
TP2- 29
TP2- 29
T P
T P
2TP2- 31
TP2- 31
TP2- 36
TP2- 36
T P
TP2- 33
TP2- 33
TP2- 38
TP2- 38
TP2- 38
TP2- 38
LD1A- 16
LD1A- 16
TP2- 40
TP2- 40
TP2- 40
TP2- 40
VESTIBULE
152A
TP2- 29
TP2- 29
TP2- 34
+42"
T P
LD1A- 5
+72"
XP
XP
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
XP
LC1- 23 LC1- 23 LE1- 29
LE1- 31LC1- 35LC1- 33
X
PANEL
RACKS
PANEL
RACKS
NOT IN SCOPE
VAV-5-1
CU-5
AHU-5
EF-4
VAV-5-6
VAV-5-7
VAV-5-4
VAV-5-3
VAV-5-2
DS-PWCONV 5
4 5
PANEL HA1-
8,10,12
1-D
1G
PANEL HA1-
38,40,42
TP2
TP2- 16
+42"
T P
T
DS-PWCONV 4
IWH-7
HA1B- 1
HA1B- 3
+42" +42" +42"
+42"
G F
C I
G F
C I
G F
C I
GFCI
GFCI
HB1B- 33,35,37
HB1A- 12,14,16
T P
,4
60AS
60AS 60AS
60AS
TP2- 45
EWH-2
NAC
PANEL X- 9
120V
CONTROL
CKT
+42"
4 4 4
+42"
2 2
VAV-5-5
C
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:5
A
M
E-012
E L E
C T
R
IC
A L P
L A
N
A R
E A
C
M S
M
IT
H
M S
M
IT
H
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
1/8" = 1'-0"1
ELECTRICAL PLAN - AREA C
SCALE:
4' 8' 16'0
1/8" = 1'-0"
2-EXPLOSION PROOF RECEPTACLES, COLUMN
MOUNTED. THE BASIS OF DESIGN IS KILLARK
UGR8-20231QW 20A CLASS 1, DIVISION 1.
480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE
4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR
SUPPORT EQUIPMENT.
ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL BE
GFCI PER NEC 210.8 REQUIREMENTS.
200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH
200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH
THAT CORRESPONDS TO DS-PWCONV 5
REPLACE EXISTING 480/277V 800A BUSWAY "BDTS"
WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW
PLUG IN UNITS, END BOXES, AND ACCESSORIES. BUS
DUCT AND ACCESSORIES SHALL BE RATED MIN IP54
AND ACCEPTABLE FOR USE IN HUMID ENVIRONMENT.
POWER CONVERTER:
INPUT: 480V, 3PH, 4W+G, 90KVA
OUTPUT: 270VDC, 400HZ, AND 28VDC
CABLE HANDLER REEL
60A, 240V or 600V, 2-POLE SWITCH
60AS, 30AF, 600V RATED, 3P, 3W+G, NEMA 1, SW
HVAC UNIT IS LOCATED ON THE 2ND LEVEL.
WIRE 120V CONTROLS CKT TO 2ND LEVEL
PANELBOARD, 3/4"C., 2#12, 1#12G, 20A CB. DOCUMENT
FOR RECORD DRAWINGS.
PROVIDE ADDITIONAL JBOXES, AND SPLICING
HARDWARE, AND APPURTENANCES AS REQUIRED TO
FACILITATE INSTALLATION OF MULTIPLE UNITS OF
EQUIPMENT ON THE SAME CIRCUIT. NOTE THAT
INDIVIDUAL SWITCHES MAY NOT BE RATED FOR FULL
CAPACITY OF LOADS.
60AS, 15AF, 600V RATED, 2P, 2W+G, NEMA 1 SW
60AS, 20AF, 600V RATED, 2P, 2W+G, NEMA 1 SW
60AS, 7AF, 600V RATED, 2P, 2W+G, NEMA 1 SW
60AS, 5AF, 600V RATED, 2P, 2W+G, NEMA 1 SW
30AS,15AF, 600V RATED, 3P, 3W+G, NEMA 1 SW
KEY NOTES:
1. COORDINATE WITH HVAC MECHANICAL
CONTRACTOR FOR INSTALLATION AND POWERING
OF HVAC EQUIPMENT FURNISHED BY THE
MECHANICAL CONTRACTOR. WHERE M-SHEETS DO
NOT INDICATE THE PROVISION OF SWITCHES BY
THE MECHANICAL CONTRACTOR THEY SHALL BE
PROVIDED BY THE ELECTRICAL CONTRACTOR.
2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL
BE GFCI PER NEC 210.8 REQUIREMENTS.
3. WHERE THE STANDARD FUSED SWITCH RATING IS
TOO LARGE FOR ACCOMODATING THE FUSE SIZE
INDICATED , PROVIDE A FUSE ADAPTER KIT.
SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND
APPROVAL WITH FUSES AND SWITCHES.
NOTES:
8 78 7
A m e n d m e n t
/8
/2
M
M
M
MOD MOD
M O
D
LOCKHEED / PMA
STORAGE
COMM
OVERFLOW
STORAGE
BREAK ROOM
LOCKHEED
OFFICE
OFFICE
SUPPORT SHOP
SHOP
MECH
WOMEN
RESTROOM
MEN RESTROOM
BATTERY
(CHARGE)
BATTERY
(STORAGE)
CORRIDOR
HEF
STORAGE
VESTIBULE
176A
STORAGE
VESTIBULE
169A
PANEL HE1
PANEL LE1
+42"
+42"
+40"
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N +40"
LD1A- 8
LD1A- 9
LD1A- 9
LD1A- 10
L D
A
LD1A- 27 LD1A- 17
LD1A- 17
LD1A- 4
L D
A
LD1A- 7
LE2- 1LE2- 1
LE1- 17
LE1- 11
LE1- 12
LE1- 16
LE1- 33
LD1A- 2
LD1A- 2
LD1A- 2
LD1A- 2
L D
A
LD1A- 7
LD1A- 7 LD1A- 7
LD1A- 11
LD1A- 11
LE1- 13LE1- 13
LE1- 5
LE1- 7
LE1- 7
LE1- 5
LE1- 7
LE1- 5
LE2- 2
LE2- 2
LE1- 11
LE1- 11
LE1- 17
LE1- 17
LE1- 17
LE1- 19
LE1- 19
LE1- 19
LE1- 14
LE1- 14
LE1- 14
LE1- 16 LE1- 12
LE1- 35
LE1- 37
GOVERNMENT
FURNISHED
CONTRACTOR
INSTALLED
XP
LE1- 29
LE1- 32
LD1A- 32
LD1A- 10
L D
A
LD1A- 8
DCU-4 DCU-3 WAC-1
DOAS-2
CU-6
NOT IN
SCOPE
NOT IN SCOPE
AHU-6
VAV-6-9
VAV-6-8
EF-6
VAV-6-6 VAV-6-5
VAV-6-4
VAV-6-3
VAV-6-2
VAV-6-1
DCU-2
EF-5
IWH-9
IWH-8
WP
GFCI
DS-PWCONV 6
VAV-6-7
LD1A
+42"
+48"
+48"
+48"
+48" +48"+36"
+48"+36"
+48" +36"
DAC-2
DAC-3
DAC-4
HE1- 33
HE1- 30
HE1- 32
HE1- 14
HE1- 16
LD1A- 11
LD1A- 10
LD1A- 32
LD1A- 34
HE1- 32
LD1A- 8
LE1- 16
LE1- 4,6 LE1- 34,36
HE1- 21,23,25
HE1- 27,29,31
HE1- 15,17,19
HE1- 24,26,28
LD1A- 4
LE1- 13
LD1A- 27
LD1A- 17
L D
A
LD1A- 2
LE1- 8
LE2
15KVA
480V-240/120V
T
LD1A- 13,15
GFCI
G F
C I
G F
C I
G F
C I
IW
H
-1
HE1- 34,36,38
HE1- 3,5,7
PLUG-IN UNIT FOR
XFMR-LE2
XFMR-LE2
LD1A- 24+48" +36"
+20"
LD1A- 6
LD1A- 18
LD1A- 20
LD1A- 21
LD1A- 23
LD1A- 22
+20"
+20"
LD1A- 25
LD1A- 29
LD1A- 31 +20"
LE1- 28
LE1- 10
LE1- 9
+48"
+36" +20"
LE1- 25
LE1- 23
LE1- 21
LD1A- 33,35
LE1- 27
AIS-1 HP1
LE1- 15
LE2-3,5
+42"
LE1- 1
LD1A- 19
LD1A- 12
100AS/40AF, 2P, 600V
100AS/40AF,
2P, 600V
KEY PLAN
D
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:0
A
M
E-013
E L E
C T
R
IC
A L P
L A
N
A R
E A
D
M S
M
IT
H
M S
M
IT
H
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
SCALE:
4' 8' 16'0
1/8" = 1'-0" 1/8" = 1'-0"1
ELECTRICAL PLAN - AREA D
2-EXPLOSION PROOF RECEPTACLES, COLUMN
MOUNTED. THE BASIS OF DESIGN IS KILLARK
UGR8-20231QW 20A CLASS 1, DIVISION 1.
480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE
4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR
SUPPORT EQUIPMENT.
200A, 3P, 4W BUS PLUG DISCONNECT SWITCH THAT
CORRESPONDS TO DS-PWCONV 6
REPLACE EXISTING 480/277V 800A BUSWAY "BDTS"
WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW
PLUG IN UNITS, END BOXES, AND ACCESSORIES. BUS
DUCT AND ACCESSORIES SHALL BE RATED MIN IP54
AND ACCEPTABLE FOR USE IN HUMID ENVIRONMENT.
POWER CONVERTER:
INPUT: 480V, 3PH, 4W+G, 90KVA
OUTPUT: 270VDC, 400HZ, AND 28VDC
CABLE HANDLER REEL
60A, 240V or 600V, 2-POLE SWITCH
60A, 600V RATED, 3P,3W+G, NEMA 1
60AS, 40AF 600V RATED, 3P,3W+G, NEMA 3R
30A, 208/240V RATED, 2P, 2W+G, NEMA 3R SW
INDOOR UNIT WIRED TO OUTDOOR UNIT IN
ACCORDANCE WITH MANUFACTURER REQUIREMENTS.
30AS, 20AF, 600V RATED, 3P, 3W+G, NEMA 3R SW
40A, 600V RATED, TOGGLE SWITCH, NEMA 1 SW
20A, 277V RATED, TOGGLE SWITCH, NEMA 1 SW
PROVIDE ADDITIONAL JBOXES, AND SPLICING
HARDWARE, AND APPURTENANCES AS REQUIRED TO
FACILITATE INSTALLATION OF MULTIPLE UNITS OF
EQUIPMENT ON THE SAME CIRCUIT. NOTE THAT
INDIVIDUAL SWITCHES MAY NOT BE RATED FOR FULL
CAPACITY OF LOADS.
240V LASER ETCHER RECEPTACLE. COORDINATE WITH
OWNER FOR RECPTACLE TYPE.
30AS/15AF, 3P, 3P,3W+G,600V,NEMA 3R SW FOR CABLE
REEL CIRCUIT (3/4"C. 3#12,1#12G).
60AS, 30AF, 600V RATE, 2P, 2W+G, NEMA 1 SW
60AS, 10AF, 600V RATE, 2P, 2W+G, NEMA 1 SW
60AS, 50AF, 600V RATE, 2P, 2W+G, NEMA 1 SW
KEY NOTES:
1. COORDINATE WITH HVAC MECHANICAL
CONTRACTOR FOR INSTALLATION AND POWERING
OF HVAC EQUIPMENT FURNISHED BY THE
MECHANICAL CONTRACTOR. WHERE M-SHEETS DO
NOT INDICATE THE PROVISION OF SWITCHES BY
THE MECHANICAL CONTRACTOR THEY SHALL BE
PROVIDED BY THE ELECTRICAL CONTRACTOR.
2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL
BE GFCI PER NEC 210.8 REQUIREMENTS.
3. WHERE THE STANDARD FUSED SWITCH RATING IS
TOO LARGE FOR ACCOMODATING THE FUSE SIZE
INDICATED , PROVIDE A FUSE ADAPTER KIT.
SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND
APPROVAL WITH FUSES AND SWITCHES.
NOTES:
12 9
15 16
A m e n d m e n t
/8
/2
AHU-4
PANEL HA1-
37,39,41
PANEL 1F- 7
PANEL 1F- 26
120V
CTRL
CKT
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:0
:4
A
M
E-014
E L E
C T
R
IC
A L P
L A
N
M E
Z Z
A N
IN
E
O C
R U
Z
A u th o r
C h e c k e r
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
SCALE:
2' 4' 8'0
1/4" = 1'-0"
1/4" = 1'-0"1
ELECTRICAL PLAN - MEZZANINE
KEY NOTES:
1. COORDINATE WITH HVAC MECHANICAL
CONTRACTOR FOR INSTALLATION AND POWERING
OF EQUIPMENT FURNISHED BY THE MECHANICAL
CONTRACTOR.
NOTES:
30AS/15AF, 600V, 3P, 3W+G, NEMA 3R, DS
A m e n d m e n t
/8
/2
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
WS
WS
OS
OS
OS
OS
PORTABLE
CRANE
PANEL
RACKS
STORAGE
106A
EJECTION SEAT
STORAGE
EGRESS OFFICE
OFFICE
MECH
CANOPY SHOP
MEN LOCKERS
WOMEN LOCKERS
FLIGHT LINE LO
OFFICE
MECH
COMM
117A
COLLATERAL
STORAGE
118A
EQUIP./HAZMAT
STORAGE
ELEC
N. ENTRY
ELEC
OFFICE
123B
OFFICE
N. VESTIBULE
OFFICE
123C
OFFICE
123A
APG
SUPERVISORS
WHEEL & TIRE
SHOP
W&T STORAGE
CORRIDOR
113A VESTIBULE
116A
EJECTION SEAT
SHOP
107A
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
G
G
G
G
G1
G1
G G1
B
W
D1 D
D D1
K
K
C1 C
E1
E
D1 D
D1
D
D1
D
C1 C
D
D1
D
D D1
K
B
Y
J1
J1
F1
F1
F
D D D D
K
D1 D D1 D
D D1
D1
F F
F1 F
F1
F
F1
GG
G1
G
G
G
G
G1
G1G
K1
V1
A
A1
A1
A
A1
A1
A
A
A1
A
K1
K
EX
EX1
EX1
EX
EX1
EX1
EX1
EX1
EX1
EX1
EX1
V1
EX1
B1
K1
C C1C
C1 CC
C1
EX
B1
EX1
EX1
A
A
A1
A
A
X
D
X
K
HB1A- 8
FIXTURE TYPE 'B' & 'B1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'C' & 'C1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'F' & 'F1'
PENDANT MTD
10'-0" AFF (TYP)
FIXTURE TYPE 'D' & 'D1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'K' & ' K1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'G' & ' G1'
PENDANT MTD 6'-9"AFF
(TYP FOR THIS ROOM)
FIXTURE TYPE 'G' & ' G1'
PENDANT MTD 8'-0" AFF
(TYP FOR THIS ROOM)
FIXTURE TYPE 'J1'
PENDANT MTD
10'-0" AFF (TYP)
FIXTURE TYPE 'E' & 'E1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'A' & 'A1'
PENDANT MTD
20'-0" AFF (TYP)
FIXTURE TYPE 'V1'
SURFACE MTD
AFF (TYP)
FIXTURE TYPE 'M'
SURFACE MTD
AFF (TYP)
FIXTURE TYPE 'K' & 'K1'
SURFACE MTD
AFF (TYP)
HB1A- 7 HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7HB1A- 7
HB1A- 7 HB1A- 7
HB1A- 7HB1A- 7
HB1A- 7 HB1A- 7
HB1A- 7HB1A- 7
HB1A- 7 HB1A- 7
HB1A- 7HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7 HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 7 HB1A- 7 HB1A- 7
HB1A- 7HB1A- 7HB1A- 7
HB1A- 7 HB1A- 7 HB1A- 7
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 7 HB1A- 7
HB1A- 7
HB1A- 7
HB1A- 8
HB1A- 8
HB1A- 8 HB1A- 8 HB1A- 8 HB1A- 8
HB1A- 8 HB1A- 8 HB1A- 8
HB1A- 8
HB1A- 8HB1A- 8
HB1A- 8
HB1A- 8 HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
FIXTURE TYPE 'EX'
WALL MTD
6" ABOVE DOOR
(TYP, SEE NOTE 1)
FIXTURE TYPE 'EX1'
CEILING MTD
(TYP, SEE NOTE 1)
FIXTURE TYPE 'X'
JOIST MTD., 200' REEL
20'-0" AFF (TYP)
FIXTURE TYPE 'W'
SURFACE MTD
AFF (TYP)
FIXTURE TYPE 'Y'
PENDANT MTD
10'-0" AFF
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8
HB1A- 8 HB1A- 8
HB1A- 8
HB1A- 8
LA2- 2
LA2- 2
HA2- 1 HA2- 1 HA2- 1
HA2- 1 HA2- 1 HA2- 1
HA2- 3HA2- 3HA2- 3
HA2- 3 HA2- 3 HA2- 3
HA2- 5HA2- 5HA2- 5
EM
Z
HB1A- 8
P P
V1
K
HB1A- 8
K1 HB1A- 8 K
HB1A- 8
HB1A- 8
HB1A- 8
M
HB1A- 8
M
HB1A- 8
HB1A- 8
FIXTURE TYPE 'P'
SURFACE MTD
AFF (TYP)
A1 HA2- 1
EX1
HB1A- 7
HB1A- 8P
EX
HB1A- 7
HB1A- 7
EX1
HB1A- 7
EX
HB1A- 8
Z
Z2
Z2
+10'4"
+13'8"
+10'4"
+10'6"
NH
NH
CANOPY TRAILER
CANOPY TRAILER
DS
1 1
EX1
HB1A- 7 1
A
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:0
A
M
E-015
L
IG
H T
IN
G
P L A
N
A R
E A
A
R R
U C
K
R R
U C
K
B P
E T
T
IF
O R
D
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
SCALE:
4' 8' 16'0
1/8" = 1'-0"
1/8" = 1'-0"2
LIGHTING PLAN - AREA A
1. EXIT SIGNS AND EMERGENCY EGRESS LIGHTS
SHALL BE WIRED TO THE NORMAL LIGHTING
CIRCUIT OF THE ROOM IT SERVES AND TO THE
LINE-SIDE OF THE LIGHT SWITCH.
2. REEL LIGHTS ARE INTENDED TO REPLACE
EXISTING. FIELD LOCATE EXISTING REEL LIGHTS
FOR REPLACEMENT WITH NEW. REEL LIGHTS
SHALL BE INSTALLED IN LOCATIONS CLOSE TO
STIFFENED TRUSS JOINTS.
3. CIRCUIT NEW OUTDOOR LIGHTS TO EXISTING
OUTDOOR LIGHTING CIRCUITS. 3/4"C., 2#8,1#8G
UNLESS OTHERWISE INDICATED.
4. REFER TO SHEETS E-008 AND E-009 FOR
ADDITIONAL LIGHTING CONTROLS REQUIREMENTS.
NOTE:
LIGHTING ZONE 'NH-A' LIGHTING ZONE 'NH-B'
KEY NOTES:
LIGHTING SCENE WALL STATION FOR LIGHTING ZONES
IN NORTH HANGAR 'NH' (NH-A THROUGH NH-C)
2 REPLACE EXISTING ARCHITECTURAL INDIRECT
WALLMOUNT SCONCES WITH NEW LED WALLMOUNT
SCONCES IN VESTIBULE.
C h a n g e
/1
/2
A m e n d m e n t
/8
/2
OS
OS OS OS
OS
OS
OS
OS
OS
OS
OS OS
OS OS
OS OS
OS
OS OS
OS
OS
W S
W S
WS
OS
OS
OS
LOCKHEED / PMA
STORAGE
COMM
OVERFLOW
STORAGE
BREAK ROOM
LOCKHEED
OFFICE
OFFICE
SUPPORT SHOP
SHOP
MECH
WOMEN
RESTROOM
MEN RESTROOM
BATTERY
(CHARGE)
BATTERY
(STORAGE)
CORRIDOR
HEF
STORAGE
VESTIBULE
176A
STORAGE
VESTIBULE
169A
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
NOT IN
SCOPE
NOT IN SCOPE
B
B1
B
B1
K
D
D1
D1
D
E1
E
D
D1
D
D
D1
D
B
B1
C1 C D D1
C
C1
C C
C C1 C
C1 C C
C C C1
U
M
M
M
R
M
M
K
K1
K1
M
L
L
K
K1
K1
F1
F
F1
F
F
F
F1
F1
F
B
K1
K1
H
H1
F F1
F
F
F1
F
F1
F
F1
F
F
K
K
K1 K K K
A
EX1
EX1
EX
EX1
EX1
EX1
EX1
EX
EX
EX
EX
EM
A1
A
A
A1
A
A
A
A1
A
A
A1
X
FIXTURE TYPE 'B' & 'B1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'E' & 'E1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'F' & 'F1'
PENDANT MTD
10'-0" AFF (TYP)
FIXTURE TYPE 'C' & 'C1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'D' & 'D1'
CEILING MTD
AFF (TYP)
FIXTURE TYPE 'N'
PENDANT MTD
10'-0" AFF (TYP)
FIXTURE TYPE 'K' & 'K1'
SURFACE MTD
AFF (TYP)
FIXTURE TYPE 'L''
SURFACE MTD
AFF (TYP)
FIXTURE TYPE 'A' & 'A1'
PENDANT MTD
20'-0" AFF (TYP)
FIXTURE TYPE 'EX1'
CEILING MTD AFF
(TYP, SEE NOTE 1)
FIXTURE TYPE 'EX'
WALL MTD
6" ABOVE DOOR AFF
(TYP, SEE NOTE 1)
FIXTURE TYPE 'EX'
WALL MTD
6" ABOVE DOOR AFF
(TYP, SEE NOTE 1)
FIXTURE TYPE 'X'
PENDANT MTD
20'-0" AFF (TYP)
FIXTURE TYPE 'EM'
WALL MTD 8'-6" AFF
(TYP, SEE NOTE 1)
HE1- 2
HE1- 2
HE1- 2
HE1- 2
HE1- 2
HE1- 2 HE1- 2
HE1- 2HE1- 2
HE1- 2 HE1- 2
HE1- 2
HE1- 2
HE1- 2
HE1- 2
HE1- 2
HE1- 2 HE1- 2 HE1- 1 HE1- 1
HE1- 1
HE1- 1
HE1- 1 HE1- 1
HE1- 4 HE1- 4 HE1- 4
HE1- 4HE1- 4HE1- 4
HE1- 4 HE1- 4 HE1- 4
HE1- 4HE1- 4HE1- 4
HE1- 4
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 4
HE1- 4
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1 HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1 HE1- 1 HE1- 1
HE1- 1HE1- 1HE1- 1
HE1- 1 HE1- 1 HE1- 1
HE1- 1 HE1- 1 HE1- 1
HE1- 1
HE1- 1
HE1- 1 HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1 HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 1
HE1- 2
HE1- 2
Z
HE1- 1
H E
EX1
HA2- 7 HA2- 7
HA2- 7 HA2- 7
HA2- 9 HA2- 9
HA2- 9 HA2- 9
HA2- 11 HA2- 11
HA2- 7 HA2- 7
HE1- 1
DS
KEY PLAN
D
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:1
A
M
E-018
L
IG
H T
IN
G
P L A
N
A R
E A
D
R R
U C
K
R R
U C
K
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
SCALE:
4' 8' 16'0
1/8" = 1'-0" 1/8" = 1'-0"1
LIGHTING PLAN - AREA D
1. EXIT SIGNS AND EMERGENCY EGRESS LIGHTS
SHALL BE WIRED TO THE NORMAL LIGHTING
CIRCUIT OF THE ROOM IT SERVES AND TO THE
LINE-SIDE OF THE LIGHT SWITCH.
2. REEL LIGHTS ARE INTENDED TO REPLACE
EXISTING. FIELD LOCATE EXISTING REEL LIGHTS
FOR REPLACEMENT WITH NEW. REEL LIGHTS
SHALL BE INSTALLED IN LOCATIONS CLOSE TO
STIFFENED TRUSS JOINTS.
3. REFER TO SHEETS E-008 AND E-009 FOR
ADDITIONAL LIGHTING CONTROLS REQUIREMENTS.
NOTE:
LIGHTING ZONE 'SH-A'
KEY NOTES:
1 LIGHTING SCENE WALL STATION FOR LIGHTING ZONES
IN NORTH HANGAR 'SH' (SH-A THROUGH SH-C)
C h a n g e
/1
/2
A m e n d m e n t
/8
/2
W
WD
S
FATR
S
FATR
TRAINING
RADIO DISPATCH
126A
OFFICE
READY ROOM
NORTH HANGAR
BAY
VESTIBULE
125A
M A
T C
H L
IN
E
S
E E
S H
E E
T E
-0 F
O R
C O
N T
IN
U
A T
IO
N
GND-001
GND-002
PANEL LA1
PANEL HA1
PANEL HC1
PANEL LC1
DIST C MAIN C TIE MAIN B DIST B
SWBD2
120/208
DIST
MAIN SWBD 480/277
SPD
480V TERMINAL BOX
PANEL 1DP
PANEL EDP1
PANEL EDP2
SWBD DISCONNECT SWITCH
PANEL IQ
PANEL 1C
PANEL 1F
PANEL 1M
PANEL 1P
APRON CONTROL PANEL
PANEL 1J
2 2
3 3
ELECTRICAL
MECHANICAL
EX. MAIN GND BUS
B
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:1
A
M
E-020
G R
O U
N D
IN
G
S Y
S T
E M
S M
O D
IF
IC
A T
IO
N
A
R E
A B
M S
M
IT
H
M S
M
IT
H
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
1/8" = 1'-0"1
GROUNDING SYSTEMS MODIFICATION -
AREA B
KEY NOTES:
COPPER GROUND BAR (SEE DETAIL E, SHEET E-034)
EXISTING LOOP STYLE GROUND RECEPTACLE
EXISTING STUD STYLE GROUND RECEPTACLE
4 1"C., 1#4/0 BARE COPPER GROUND TO
MAIN ELECTRICAL GND BUS LOCATED IN
ROOM
5 1#4/0 BARE COPPER GROUND
A m e n d m e n t
/8
/2
SCALE:
4' 8' 16'0
1/8" = 1'-0"
3 3
GND-032
GND-033
A
KEY PLAN
TR
U E N
PLAN
NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10
F
D
B
M W
A
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
J A
C K
S O
N V
IL
L E
A N
G B
F
L O
R
ID
A
P a rk w a y L a n e S u it e
P e a c h tr e e C o rn e rs
L
IC
E N
S E
N U
M B
E R
S
A R
C H
IT
E
C T
U R
E
A A
E N
G
IN
E E
R
IN
G
C o A
N o .8
S o u th a ll
L a n e
S u it e
M a it la n d
F L
T e l:
-2
F L A
C O
A N o
E B
-0
B
IM
/1
F
L A
N G
F -3 c o n v e rs io n H a n g a r/
F L A
N G
H a n g a r_ E
L E
C v
.r v t
/2
/2
:1
:2
A
M
E-022
G R
O U
N D
IN
G
S Y
S T
E M
S M
O D
IF
IC
A T
IO
N
A
R E
A D
M S
M
IT
H
M S
M
IT
H
O C
R U
Z
/2
/2
B -3
S U
B M
IT
T
A L
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N th
F
IG
H T
E R
W
IN
G J A
C K
S O
N V
IL
L E
F
L
F -3
R
E P
A
IR
H A
N G
A R
B
L D
G
L S
G A
1/8" = 1'-0"1
GROUNDING SYSTEMS MODIFICATION -
AREA D
KEY NOTES:
COPPER GROUND BAR (SEE DETAIL E, SHEET E-034)
EXISTING LOOP STYLE GROUND RECEPTACLE
EXISTING STUD STYLE GROUND RECEPTACLE
4 1"C., 1#4/0 BARE COPPER GROUND TO
MAIN ELECTRICAL GND BUS LOCATED IN
ROOM
5 1#4/0 BARE COPPER GROUND
1#4/0 BARE COPPER GROUND TO
BUILDING STEEL. SEE DETAIL G ON
DRAWING DETAIL I, E-032.
A m e n d m e n t
/8
/2
SCALE:
4' 8' 16'0
1/8" = 1'-0"
| E002 |
| Plot |
| E007 |
| Plot |
| E-008 |
| E-010 |
| E-011 |
| E-012 |
| E-013 |
| E-014 |
| E-015 |
| E-018 |
| E-020 |
| E-021 |
| E-022 |
File details come from the government source that posted it. Updated .