Rev 2 Attach-2 V-HH. ELEC Adend 2.pdf

PDF 17 MB Posted

Attached to
Repair Maintenance (MTX) Hangar Building 1001 (B1001)
Solicitation number
W50S6Y24B0002
Issued by

About this file

This document appears to be an amendment to the solicitation for the F-35 Repair Maintenance Hangar B1001 project (Solicitation # W50S6Y-24-B-0002) issued by the Department of the Army Florida Army National Guard.

The project involves the repair and full renovation of the ground floor spaces of Maintenance Hangar Building 1001 at the 125th Fighter Wing Jacksonville International Airport to enable the F-35 Fighter Mission. The work includes demolition, new interior construction and finishes, HVAC, plumbing, electrical, lighting, grounding, fire protection, telecommunication, and access control/security systems. The estimated Period of Performance is 540 Calendar Days after Notice to Proceed. This is a Small Business Set-Aside opportunity with a NAICS code of 236220 and a $45M size standard. The project magnitude is between $10M to $20M. Failure to submit an offer on all items will result in bid rejection. The solicitation and all related information will be posted on SAM.gov. Award will be made to the responsible bidder whose bid conforms to the IFB and is most advantageous to the Government based on price and price-related factors.

View the file

Other files

File Type Posted
Repair Hanger Abstract OF_1419-4.25.24-KO.pdf PDF
Bid Submission Day Sign-In Sheet-25APR24.pdf PDF
W50S6Y24B0002_00004 Repair MTX_19Apr24.pdf PDF
Rev 3 Attach-2 Adend 3- Electrical E-ED.pdf PDF
Set 06_Q-A_W50S6Y24B0002 Hanger.pdf PDF
QA Set 05 W50S6Y24B0002 Hanger.docx DOCX document
Rev 2 Attach-2 U. P-110B Adend 2.pdf PDF
Rev 2 Attach-2 E-M. STRC Adend 2.pdf PDF
Rev 2 Attach-2 C. CS402 ADEND2 signed.pdf PDF
Set 05_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Rev 2 Attach-2 A. CD100 Adend 2 signed.pdf PDF
Rev 2 Attach-2 B. CU100 Adend 2 signed.pdf PDF
Rev 2 Attach-2 N-T. ARCH & Interiors Adend 2.pdf PDF
Rev 2 Attach-1_22 00 00 Specs.pdf PDF
Rev 2 Attach-2 D. CS403 Adend 2 signed.pdf PDF
W50S6Y24B0002_00003 Repair MTX_3Apr24.pdf PDF
Rev 2 Attach-2 II. TY-101 ADEND #2.pdf PDF
Notifier Panel Pics.pdf PDF
Set 04_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Set 03_Q-A_W50S6Y24B0002 Hanger.pdf PDF
W50S6Y24B0002_00002 Repair MTX_28Mar24.pdf PDF
Site Visit Sign-In Sheet-20MAR24.pdf PDF
Hanger Pre-Proposal minutes.pdf PDF
MTX Pre-Bid slides B1001.pptx PPTX presentation
Set 02_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Addendum 01_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Attach-7-125FW Form 2 Fillable (Aug 2023) - CAO 01MAR2024.pdf PDF
Rev 1 Attach-2-LSGA212001_B1001 Hangar Combined Drawings B-3_3.4.24.pdf PDF
Rev 1 Attach-1-LSGA212001_B1001 Hangar Combined Specifications B-3_3.4.24.pdf PDF
W50S6Y24B0002_00001 Repair MTX_5Mar24.pdf PDF
Attach-1-LSGA 212001_B1001 Hangar Combined Specifications B-3.pdf PDF
Attach-7-125FW Form 2 Installation Access Request dated Sep 2022.pdf PDF
Attach-4-JA-SS-LSGA212001-B-Advantor_Redacted.pdf PDF
Attach-2-LSGA 212001_B1001 Hangar Combined Drawings B-3.pdf PDF
Attach-3-JA-BN-LSGA212001-A-Best Locks_Cores-Redact.pdf PDF
W50S6Y24B0002 Repair MTX_29FEB24.pdf PDF
Attach-5-JA-BN-LSGA212001-C-Monaco-Redact.pdf PDF
Attach-6-JA-BN-LSGA212001-D-JCI Metasys-Redact.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

/2

0/

IS

SU

E

D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 3 5 7 9

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10

F

D

B

B-

SU

BM

IT

TA

L

- I

SS

U

E

FO

R C

O N

ST

R

U C

TI

O

N

FL

O

R

ID

A

AI

R N

AT

IO

N

AL

G U

AR

D

JA

C

KS

O

N

VI

LL

E

AN

G

B, F

LO

R

ID

A

P ar kw ay

L an e Su ite

Pe ac ht re e

C or ne rs

, G A

LI

C

EN

SE

N

U M

BE

R

S:

AR

C H

IT

EC

TU

R

E:

A

A2

EN

G

IN

EE

R

IN

G

C oA N o.

So ut ha ll

La ne

, S ui te

M ai tla nd , F

L

Te l:

(4

) 6

-2

FL

A C

O A

N o.

E B-

5t h

FI

G H

TE

R

W

IN

G J

AC

KS

O N

VI

LL

E, F

L, F-

R

EP

AI

R

H

AN

G

AR

, B

LD

G

LS

G

A2

E-002

EL

EC

TR

IC

AL

LE

G

EN

D

II

O . C

R U

Z

R . R

U C

K

B.

P

ET

TI

FO

R

D

S.

P

ER

R

Y

AM

EN

D M

EN

T

#2 3/

8/

XR

EF

s:

[2

9_

AN

SI

D _2

2x

_B or de r_

U

SA

C E]

Im ag es

La st s av ed b y:

R

U C

KR

M

T im e:

/8 /2

1:

:2

PM

pw cd m sm ith -a z0 2-pw .b en tle y.

co m :p w _p l1 \2

8\

\0

D es ig n

Se rv ic es

N M

_5

\0

El ec tri ca l\1

BI

M

_C

AD

D \X

XX

X#

#E

2.

dw g

GENERAL NOTE

THIS IS A STANDARD LEGEND.

SOME SYMBOLS MAY NOT

APPEAR ON THE DRAWINGS.

ABBREVIATIONS (CONTINUED)

MAX MAXIMUM

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR

MDP MAIN DISTRIBUTION PANEL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MLO MAIN LUGS ONLY

MTD MOUNTED

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

N NEUTRAL

NC NORMALLY CLOSED

NO NORMALLY OPEN OR NUMBER

NTS NOT TO SCALE

OH OVERHEAD

OL OVERLOAD

PB PULL BOX

PCP PUMP CONTROL PANEL

PH PHASE

PMH POWER MANHOLE

PNL PANEL OR PANELBOARD

PR PAIR

PRI PRIMARY

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE

RECPT RECEPTACLE

REQD REQUIRED

QTY QUANTITY

SA SURGE ARRESTER

SEC SECONDS OR SECONDARY

SH SHIELDED OR SPACE HEATER

SPD SURGE PROTECTIVE DEVICE

SS STAINLESS STEEL

SV SOLENOID VALVE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TC TIME TO CLOSE OR TRAY CABLE

TEL TELEPHONE

TO TIME TO OPEN

TS TWISTED SHIELDED OR THERMAL

SWITCH

TYP TYPICAL

UG UNDERGROUND

UPS UNINTERRUPTIBLE POWER

SUPPLY

V VOLTS

VA VOLT AMPS

VFD VARIABLE FREQUENCY DRIVE

W WATTS, WIDTH, WITH, WIRE

WP WEATHERPROOF

XP EXPLOSION PROOF

XFMR TRANSFORMER

ABBREVIATIONS

A AMPS

AC ALTERNATING CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AL ALUMINUM

AIC AMPERE INTERRUPTING CAPACITY

AMP AMPERE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AWG AMERICAN WIRE GAUGE

BKR BREAKER

BLDG BUILDING

C CONDUIT

CB CIRCUIT BREAKER

CGD COMBUSTIBLE GAS DETECTOR

CKT CIRCUIT

CLB CURRENT LIMITING BREAKER

CLF CURRENT LIMITING FUSE

CP CONTROL PANEL

CPT CONTROL POWER TRANSFORMER

CR CONTROL RELAY

CS CONTROL SWITCH/CONTROL STATION

CT CURRENT TRANSFORMER

CU COPPER

CWS CONDUIT WALL SEAL

DC DIRECT CURRENT

DIA DIAMETER

DMU DIGITAL METERING UNIT

DN DOWN

EC EMPTY CONDUIT

ELEC ELECTRICAL

ELEV ELEVATION

EM EMERGENCY

ENCL ENCLOSURE OR ENCLOSED

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EX EXISTING

FO FIBER OPTIC

FU FUSE

GCP GENERATOR CONTROL PANEL

GEN GENERATOR

G, GND GROUND

GFI GROUND FAULT INTERRUPTER

GRS GALVANIZED RIGID STEEL

HACR HEATING & AIR CONDITIONING RATED

HH HANDHOLE

HT HEIGHT

HID HIGH INTENSITY DISCHARGE

HP HORSEPOWER

HZ HERTZ

ID IDENTIFICATION

INSTR INSTRUMENT

K KILO (PREFIX)

kcmil 1000 CIRCULAR MILS

KVA KILOVOLT AMPERES

KW KILOWATTS

LA LIGHTNING ARRESTER

LTG LIGHTING

LP LIGHTING PANEL

LV LOW VOLTAGE

FB

GROUND SYSTEM GRID OR LOOP, 36" BELOW FINISHED GRADE UNLESS

OTHERWISE NOTED.

DUPLEX RECEPTACLE, 20A, 120V, 2P, 3W

MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED

* GFCI - GROUND FAULT CIRCUIT INTERRUPTER TYPE

WP - WEATHERPROOF

XP - EXPLOSION PROOF

T - TRANSIENT VOLTAGE SURGE SUPPRESSOR

4 - CIRCUIT NUMBER

+*" - MOUNTING HEIGHT AFF

DUPLEX RECEPTACLE, 20A, 120V, 2P, 3W

MOUNTED ABOVE COUNTER-TOP OR 42" AFF UNLESS OTHERWISE NOTED

* NOTATIONS SAME AS ABOVE

WALL MOUNTED EXIT SIGN, NOTATIONS SAME AS ABOVE. WHEN USED,

ARROW INDICATES DIRECTION OF EGRESS. FILLED QUADRANT REPRESENTS

FACE SIDE OF SIGN.

COMBINATION BATTERY UNIT AND EXIT SIGN. FILLED QUADRANT

REPRESENTS FACE SIDE OF SIGN.

DENOTES A QUANTITY OF TWO (2) 3-INCH CONDUITS EACH CONTAINING

THREE NO. 3/0 AWG CONDUCTORS AND 1 NO. 2 AWG GROUND CONDUCTOR.

DENOTES A QUANTITY OF TWO INSTRUMENT CABLES. EACH CABLE TO

CONSIST OF TWO NO. 16 AWG CONDUCTORS TWISTED TOGETHER AND

COVERED WITH A METALLIC SHIELD AND AN OVERALL PROTECTIVE JACKET.

REFER TO THE SPECIFICATIONS FOR THE EXACT CABLE TO BE PROVIDED.

HOME RUN TO DESIGNATED EQUIPMENT. BRANCH CIRCUIT CONDUIT WITH 2

NO. 12 AWG BRANCH CIRCUIT CONDUCTORS AND 1 NO. 12 AWG GROUND

CONDUCTOR UNLESS OTHERWISE NOTED. NUMBER OF ARROWS INDICATE

NUMBER OF CIRCUITS. FOR MINIMUM SIZE CONDUIT PERMITTED REFER TO

THE SPECIFICATIONS.

CROSS HATCH INDICATES LIGHTING FIXTURE THAT IS UNSWITCHED AND

SHALL REMAIN ON AT ALL TIMES. NOTATIONS SAME AS ABOVE.

DOUBLE POLE SWITCH

"OS" INDICATES PROGRAMMABLE OCCUPANCY SENSOR CAPABLE OF

INBOARD/OUTBOARD SWITCHING

SINGLE POLE SWITCH

"OS" INDICATES A PASSIVE INFRARED OCCUPANCY SENSOR

HORSEPOWER RATED TOGGLE SWITCH. VOLTAGE AND CURRENT

COORDINATED WITH UNIT BEING POWERED.

DESCRIPTIONSYMBOL

LIGHTING FIXTURE

"A" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)

"b" - CONTROLLED BY SWITCH "b"

"3" - CIRCUIT NUMBER

LIGHTING FIXTURE, NOTATIONS SAME AS ABOVE

WALL MOUNTED TYPE LIGHTING FIXTURE, NOTATIONS SAME AS ABOVE

EMERGENCY LIGHTING BATTERY UNIT WITH TWO LAMP HEADS

"EM" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)

"3" - SUPERVISORY CIRCUIT

* - FIXTURE TAG #

REMOTE EMERGENCY ADJUSTABLE WALL LIGHTING FIXTURE WITH TWO LAMP

HEADS

"R-2" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)

* - HOME RUN TO BATTERY UNIT INDICATED. CONDUIT

SHALL BE 3/4" AND CONTAIN (2) NO. 12 AWG BRANCH

CIRCUIT CONDUCTORS AND (1) NO. 12 AWG GROUND

CONDUCTOR UNLESS OTHERWISE INDICATED.

REMOTE EMERGENCY CEILING LIGHTING FIXTURE.

"RH-3" - FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE)

"3" - SUPERVISORY CIRCUIT

* - HOME RUN TO BATTERY UNIT INDICATED. CONDUIT

SHALL BE 3/4" AND CONTAIN 2 NO. 12 AWG BRANCH

CIRCUIT CONDUCTORS AND 1 NO. 12 AWG GROUND

CONDUCTOR UNLESS OTHERWISE INDICATED.

CONDUIT CONCEALED IN WALL, IN SLAB ABOVE, OR ABOVE CEILING.

CONDUIT RUN EXPOSED. RUN PARALLEL OR PERPENDICULAR TO STRUCTURE

OR WALL.

CONDUIT STUBBED OUT AND CAPPED

SAME AS ABOVE EXCEPT CABLE TO CONSIST OF THREE NO. 16 AWG

CONDUCTORS TWISTED, SHIELDED AND COVERED WITH AN OVERALL

PROTECTIVE JACKET. REFER TO THE SPECIFICATIONS FOR THE EXACT CABLE

TO BE PROVIDED.

POLE MOUNTED AREA TYPE LIGHTING FIXTURE, NOTATIONS SAME AS ABOVE

CEILING MOUNTED EXIT SIGN, NOTATIONS SAME AS ABOVE. WHEN USED,

ARROW INDICATES DIRECTION OF EGRESS. FILLED QUADRANT REPRESENTS

FACE SIDE OF SIGN. (DOUBLE FACE DOUBLE CHEVRONS SHOWN)

CONDUIT CONCEALED IN OR BELOW FLOOR OR UNDERGROUND.

CONCRETE ENCASED DUCTBANK. WIDTH VARIES, SEE DUCTBANK

SECTION/DETAILS FOR REQUIREMENTS AND WIDTH

THREE 4-INCH CONDUITS

FLEXIBLE METAL CONDUIT "WHIP" (3/4"C., 2#12, 1#12G UNLESS OTHERWISE

NOTED) FOR LIQUID TIGHT MOTOR CONNECTIONS

'X' INDICATES CONDUIT SEAL FITTING IN OTHER THAN CODE REQUIRED

LOCATIONS.

INDICATES MOTOR STARTER AND/OR MOTOR CONTROL EQUIPMENT WITHIN

THE ENCLOSURE.

DESCRIPTIONSYMBOL

SINGLE POLE SWITCH "a" INDICATES FIXTURES CONTROLLED.

DOUBLE POLE SWITCH "a" INDICATES FIXTURES CONTROLLED.

THREE WAY SWITCH "c" INDICATES FIXTURES CONTROLLED.

FOUR WAY SWITCH "a" INDICATES FIXTURES CONTROLLED.

DIMMER SWITCH "a" INDICATES FIXTURES CONTROLLED

LIGHTING CONTACTOR WITH NUMBER OF POLES AS INDICATED

TIME SWITCH

INDICATES ALL LIGHTING FIXTURES WITHIN THE ROOM OR AREA IN WHICH

THIS NOTATION APPEARS SHALL BE TYPE "A" UNLESS OTHERWISE NOTED.

SEE LIGHTING FIXTURE SCHEDULE FOR TYPES

LIGHTING PANELBOARD (LP-#)

SHOWN ON PLAN PER ACTUAL PANEL DIMENSIONS

POWER PANELBOARD (PP-#) OR DISTRIBUTION PANELBOARD (DP-#) SHOWN

ON PLAN PER ACTUAL PANEL DIMENSIONS

PUSH BUTTON STATION

SPECIAL PURPOSE RECEPTACLE

* - VOLT RATING

"3" - NUMBER OF POLES

"60" - AMPERE RATING

"4W" - 4 WIRES IN ADDITION TO GROUND

MULTI-OUTLET ASSEMBLY, SYMBOL DENOTES RECEPTACLE TYPE

FLUSH FLOOR OUTLET BOX WITH TYPE OUTLET INDICATED

UNDER FLOOR DUCT SYSTEM WITH TYPE OUTLETS INDICATED

THREE CELL UNDER FLOOR DUCT SYSTEM JUNCTION BOX

JUNCTION BOX

PULL BOX

TERMINAL CABINET

OCCUPANCY SENSOR

PHOTOCELL

EMERGENCY EYEWASH/SHOWER ALARM STATION WITH FLOW SWITCH(ES)

GLASS BREAK DETECTOR

PAN, TILT, ZOOM CAMERA LENS CONTROLS

CLOSED CIRCUIT TV CAMERA

SECURITY ALARM MOTION DETECTOR

SECURITY ALARM WINDOW SWITCH

SECURITY SYSTEM CARD ACCESS READER

SECURITY ALARM KEY PAD

SECURITY ALARM DOOR SWITCH

SECURITY ALARM CONTROL PANEL

"C" - DATA INPUT/OUTPUT CABLE OUTLET

"P" - PROCESS COMPUTER SYSTEM (CAT6 RJ-45 JACK)

TELEPHONE CABINET OR BACKBOARD AS NOTED

PAGING SPEAKER AMPLIFIER ASSEMBLY

REMOTE WALL MOUNTED VOLUME CONTROL FOR CEILING SPEAKER, MOUNT

UP 5'-0"

PAGING SPEAKER, SURFACE MOUNTED CEILING TYPE

PAGING SPEAKER, FLUSH MOUNTED CEILING TYPE

PAGING SPEAKER, WALL MOUNTED, BI-DIRECTIONAL, HORN TYPE

W = WIDE ANGLE TYPE

PAGING SPEAKER, WALL MOUNTED

H = HORN TYPE

W = WIDE ANGLE TYPE

PAGE/PARTY TELEPHONE OUTLET FOR WALL TYPE HANDSET, MOUNT UP 4'-6"

PAGE/PARTY TELEPHONE OUTLET FOR DESK TYPE HANDSET

TELEPHONE OUTLET FOR WALL TYPE HANDSET (MOUNT UP 4'-6")

K = KEY SYSTEM

TELEPHONE OUTLET FOR DESK TYPE HANDSET

K = KEY SYSTEM

INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED

WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL BE OF

NEMA 4X CONSTRUCTION (OR CORROSION RESISTANT CONSTRUCTION

SUITABLE FOR USE IN A WET LOCATION WHERE NEMA STANDARDS DO NOT

APPLY) UNLESS OTHERWISE NOTED.

INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED

WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL BE OF

NEMA 4X CONSTRUCTION (OR GASKETED AND SUITABLE FOR USE IN A WET

LOCATION WHERE NEMA STANDARDS DO NOT APPLY) UNLESS OTHERWISE

NOTED.

INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED

WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL BE OF

NEMA 12 CONSTRUCTION (OR GASKETED AND SUITABLE FOR USE IN A WET

LOCATION WHERE NEMA STANDARDS DO NOT APPLY) UNLESS OTHERWISE

NOTED.

FIRE ALARM HEAT DETECTOR 135 FIXED TEMPERATURE UNLESS OTHERWISE

NOTED.

"200" - 200 FIXED TEMPERATURE

"R" - FIXED TEMPERATURE RATE-OF-RISE TYPE

FIRE ALARM SMOKE DETECTOR PHOTOELECTRIC TYPE UNLESS OTHERWISE

NOTED.

"I" - IONIZATION TYPE.

FIRE ALARM DUCT SMOKE DETECTOR

FIRE ALARM CONTROL PANEL

FIRE ALARM VENTILATION PANEL WITH GRAPHIC PANEL

REMOTE FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM MASTER BOX

FIRE ALARM HORN, MOUNT UP 7'-6"

SPRINKLER VALVE SUPERVISORY SWITCH

SPRINKLER FLOW ALARM SWITCH

FIRE ALARM BELL

WEATHERPROOF HI-INTENSITY FIRE ALARM STROBE LIGHT WITH HORN

PASSIVE INFRARED DETECTOR

SMOKE BEAM DETECTOR (RECEIVER)

SMOKE BEAM DETECTOR (TRANSMITTER)

FIRE ALARM SMOKE DETECTOR REMOTE INDICATOR AND TEST SWITCH

OR

A 3 b

A 3 b

A 3

A 3 b

3A

3A

EM

BU-1(*)

R-2

A 3

A

A 3

BU-1(*)E

RH-3

(2) 3"C., 3#3/0, 1#2G

2-2/C#16 SH

2-3/C#16 SH

(3) 4"C.

C 3

TYPE A

TC

P

J OR J

OS

PC

DESCRIPTIONSYMBOL

INDICATED EQUIPMENT AND MATERIALS TO BE DEMOLISHED

4W

DUST

DAMP

WET

CORROSIVE

OR

EXOTHERMIC WELD CONNECTION

3/4" x 10'-0" GROUND ROD. UNLESS SPECIFIED OTHERWISE.

GROUND ROD TEST WELL STATION

(SEE DETAIL SHEET FOR REQUIREMENTS)

COMMUNICATION SYSTEMS

K

K

S H W

S W

S

S

VC

A

TM

SECURITY SYSTEMS

K

SACP

DS

R

WS

CCTV

PTZ

GB

FIRE ALARM SYSTEMS

FACP

FV

FA

VSS

SFS

PIR

F

F

H R

I

D

DESCRIPTIONSYMBOL

F

R

T a a c a D

OS

OS

M a

POLE MOUNTED ROADWAY TYPE LIGHTING FIXTURE, NOTATIONS SAME AS

ABOVE

SHADED AREA INDICATES LIGHTING FIXTURE THAT IS EQUIPPED WITH

EMERGENCY BACKUP POWER SOURCE. NOTATIONS SAME AS ABOVE.OR

A 3 b b

3A

INDICATES THAT ALL ELECTRICAL EQUIPMENT AND MATERIALS INSTALLED

WITHIN THE ROOM OR AREA IN WHICH THIS NOTATION APPEARS SHALL

CONFORM TO N.E.C. REQUIREMENTS FOR THE HAZARDOUS AREA

CLASSIFICATION SHOWN.

CLASS I, DIV. 1

GROUP D

FIRE ALARM STROBE, MOUNT UP 6'-8"

15 = CANDELA RATING

FIRE ALARM HORN AND STROBE LIGHT COMBINATION, MOUNT UP 6'-8"

15 = CANDELA RATING

FIRE ALARM MANUAL PULL STATION, MOUNT UP 4'-0"F

F

F

LIGHTING CONTACTOR PANELBOARD (LCP-#)

SHOWN ON PLAN PER ACTUAL PANEL DIMENSIONS

A 3

ESA

C

OR

1 = MASTER, 2 = REMOTE

GAS DETECTOR/VENTILATION FAILURE ALARM,

# INDICATES TYPE OF UNIT.GD/VF

GB GAS DETECTION/VENTILATION FAILURE WEATHERPROOF DUAL-LITE BEACON

MOUNT TOP OF DEVICE UP 6'-8" A.F.F.

G

MOUNT TOP OF DEVICE UP 6'-8" A.F.F.

GAS DETECTION/VENTILATION FAILURE HORN/STROBE

GAS DETECTION/VENTILATION FAILURE HORN,

G MOUNT TOP OF DEVICE UP 6'-8" A.F.F.

G GAS DETECTION/VENTILATION FAILURE STROBE,

MOUNT TOP OF DEVICE UP 6'-8" A.F.F.

'X' INDICATES EXPLOSION PROOF CONDUIT SEAL FITTING.

DUPLEX RECEPTACLE - ONE RECEPTACLE CONTROLLED

MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED

* NOTATIONS SAME AS ABOVE

UON UNLESS OTHERWISE NOTED

EXPLOSIONPROOF (CLASS 1, DIVISION I) REEL LIGHT - 200' SOOW CORD

A3

4 +*"

DOUBLE DUPLEX RECEPTACLE - TWO CONTROLLED RECEPTACLES

MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED

* NOTATIONS SAME AS ABOVE

DOUBLE DUPLEX RECEPTACLE, 20A, 120V, 2P, 3W

MOUNTED AT 24" AFF UNLESS OTHERWISE NOTED

* NOTATIONS SAME AS ABOVE

PLUG LOAD CONTROLLER

R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

/2

0/

IS

SU

E

D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 3 5 7 9

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10

F

D

B

B-

SU

BM

IT

TA

L

- I

SS

U

E

FO

R C

O N

ST

R

U C

TI

O

N

FL

O

R

ID

A

AI

R N

AT

IO

N

AL

G U

AR

D

JA

C

KS

O

N

VI

LL

E

AN

G

B, F

LO

R

ID

A

P ar kw ay

L an e Su ite

Pe ac ht re e

C or ne rs

, G A

LI

C

EN

SE

N

U M

BE

R

S:

AR

C H

IT

EC

TU

R

E:

A

A2

EN

G

IN

EE

R

IN

G

C oA N o.

So ut ha ll

La ne

, S ui te

M ai tla nd , F

L

Te l:

(4

) 6

-2

FL

A C

O A

N o.

E B-

5t h

FI

G H

TE

R

W

IN

G J

AC

KS

O N

VI

LL

E, F

L, F-

R

EP

AI

R

H

AN

G

AR

, B

LD

G

LS

G

A2

E-006

EX

IS

TI

N

G D

EM

O

LI

TI

O N

O N

E

LI

N E

PO

W

ER

D

IA

G

R

AM

O . C

R U

Z

R . R

U C

K

B.

P

ET

TI

FO

R

D

S.

P

ER

R

Y

AM

EN

D M

EN

T

#2 3/

8/

XR

EF

s:

[2

9_

AN

SI

D _2

2x

_B or de r_

U

SA

es

La st s av ed b y:

R

U C

KR

M

T im e:

/3 /2

9:

:3

AM

pw cd m sm ith -a z0 2-pw .b en tle y.

co m :p w _p l1 \2

8\

\0

D es ig n

Se rv ic es

N M

_5

\0

El ec tri ca l\1

BI

M

_C

AD

D \X

XX

X#

#E

6.

dw g

R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

/2

0/

IS

SU

E

D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 3 5 7 9

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10

F

D

B

B-

SU

BM

IT

TA

L

- I

SS

U

E

FO

R C

O N

ST

R

U C

TI

O

N

FL

O

R

ID

A

AI

R N

AT

IO

N

AL

G U

AR

D

JA

C

KS

O

N

VI

LL

E

AN

G

B, F

LO

R

ID

A

P ar kw ay

L an e Su ite

Pe ac ht re e

C or ne rs

, G A

LI

C

EN

SE

N

U M

BE

R

S:

AR

C H

IT

EC

TU

R

E:

A

A2

EN

G

IN

EE

R

IN

G

C oA N o.

So ut ha ll

La ne

, S ui te

M ai tla nd , F

L

Te l:

(4

) 6

-2

FL

A C

O A

N o.

E B-

5t h

FI

G H

TE

R

W

IN

G J

AC

KS

O N

VI

LL

E, F

L, F-

R

EP

AI

R

H

AN

G

AR

, B

LD

G

LS

G

A2

E-007

O N

E

LI

N E

PO

W

ER

D

IA

G

R

AM

O . C

R U

Z

R . R

U C

K

B.

P

ET

TI

FO

R

D

S.

P

ER

R

Y

AM

EN

D M

EN

T

#2 3/

8/

XR

EF

s:

[2

9_

AN

SI

D _2

2x

_B or de r_

U

SA

es

La st s av ed b y:

R

U C

KR

M

T im e:

/3 /2

9:

:1

AM

pw cd m sm ith -a z0 2-pw .b en tle y.

co m :p w _p l1 \2

8\

\0

D es ig n

Se rv ic es

N M

_5

\0

El ec tri ca l\1

BI

M

_C

AD

D \X

XX

X#

#E

7.

dw g

42KAIC

ON/OFF

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

G

A

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:0

A

M

E-008

L

IG

H T

IN

G

C O

N T

R O

L R

IS

E

R D

IA

G

R A

M S

I

O C

R U

Z

R R

U C

K

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

DEVICE LEGEND

EQPMT ID. DEVICE TYPE

OS OCCUPANCY SENSOR

DAYLIGHT SENSOR

POWER PACK/LIGHTING RELAY (0-10V) DIMMING

LINE VOLTAGE MULTI-WAY SWITCH

ON/OFF - RAISE LOWER CONTROL

LINE VOLTAGE MULTI-WAY SWITCH

ON/OFF CONTROL

LINE OR LOW VOLTAGE SWITCH

ON/OFF - RAISE LOWER CONTROL

LINE VOLTAGE SWITCH

ON/OFF CONTROL

EMERGENCY POWER PACK/LIGHTING RELAY

(0-10V) DIMMING

EMERGENCY POWER PACK/LIGHTING RELAY

POWER PACK/ LIGHTING RELAY

PLUG LOAD CONTROL POWER PACK/LIGHTING RELAY

NOTES:

RISER DIAGRAMS SHOWN ARE TYPICALS AND ILLUSTRATE

CONCEPTUAL CONTROL SEQUENCE. ACTUAL WIRING IS

MANUFACTURER DEPENDENT. REFER TO PLAN DRAWINGS FOR

QUANTITY OF DEVICES AND LOCATIONS. ADDITIONAL DEVICES MAY BE

REQUIRED TO IMPLEMENT CONTROL FUNCTIONS. PROVIDE ALL

EQUIPMENT INCLUSIVE OF HEADEND EQUIPMENT REQUIRED FOR

FULL LIGHTING SYSTEM OPERATION. CONSULT MANUFACTURER FOR

FINAL WIRING DIAGRAMS AND SUBMIT TO ENGINEER FOR APPROVAL

AS A SHOP DRAWING.

CONTRACTOR SHALL SUBMIT FULL DIAGRAMS FOR ALL LIGHTING

CONTROL SPACES AS A SHOP DRAWING.

1.

RISER DIAGRAM

NTS

RISER DIAGRAM

ON/OFF/0-10V DIMMING (RAISE/LOWER)

NTS

H

LOAD

N

WHITE W/ BLUE STRIPE

CAP OFF

WHITE W/ BLUE STRIPE

N H

BLK-120V

ORN-277V

RED

WHITE

BLACK

BLUE

BLUE

BLK/ORG

WHITE

LOAD

BLACK

WHITE

BLACK

WHITE

BLACK (COMMON)

YELLOW/BLACK

YELLOW

BLACK

WHITE

BLACK

WHITE

RED

RED

RED 12-24V POWER

RED

RED

WHITE

AUTO ON/OFF W/ THREE WAY

SWITCHING AND 0-10V DIMMING

LIGHTING CONTROLS

ROOM NO. DESCRIPTION

110 MECH/ELEC ROOM

ELECTRICAL

BLDG-1001

114 MECH/ELEC ROOM

ELECTRICAL

127B MECH ROOM

ELECTRICAL ROOM139A

182 MECH ROOM

LIGHTING CONTROLS

ROOM NO.

106A STORAGE

BLDG-1001

106 EJECTION SEAT STORAGE

EGRESS OFFICE107

DESCRIPTION

RISER DIAGRAM

NTS

AUTO ON/OFF W/ MULTI WAY

SWITCHING AND 0-10V DIMMING

LIGHTING CONTROLS

ROOM NO.

BLDG-1001

DESCRIPTION

116 FLIGHT LINE LO

127 READY ROOM

134 ELEVATOR ELECTRICAL

DS

PPd

EPPd

EPP

PP

PL

SWd

SWa

SWb

SWc

PHOTOCELLPC

113A CORRIDOR

RISER DIAGRAM

NTS

HANGAR BAY

RISER DIAGRAM

NTS

ON/OFF/0-10V DIMMING (RAISE/LOWER) W/

OCCUPANCY SENSOR

ROOM NO. DESCRIPTION

107A EJECTION SEAT SHOP

103 WHEEL & TIRE SHOP

CANOPY SHOP108

COMM

VESTIBULE OR CORRIDOR

121 N. ENTRY

123B OFFICE

OS/DS

RED

WHITE

BLACK

BLACK

RED

WHITE

BLACK

WHITE

RED

WHITE

BLK/ORG

BLUE

BLUE

BLACK

RED

BLACK

RED

WHITE

BLACK

WHITE

RED

BLACK

RED

WHITE

WHITE

RED

BLACK

WHITE

WHITE

RED

BLACK

BLACK

WHITE

RED

WHITE W/ BLUE STRIPE

VIOLET

(DIMMING 0-10VDC OUTPUT)

TO VIOLET WIRE ON DIMMING BALLAST

GREY WIRE FROM BALLAST

IS CONNECTED TO THE BLACK WIRE

ON THE LOW VOLTAGE SIDE OF

THE POWER PACK GREY

BLUE

BLUE

BLK/ORG

WHITE

BLUE

BLUE

BLK/ORG

WHITE

GREY

GREY WIRE FROM BALLAST

IS CONNECTED TO THE BLACK WIRE

ON THE LOW VOLTAGE SIDE OF

THE POWER PACK

WHITE W/ BLUE STRIPE

VIOLET

(DIMMING 0-10VDC OUTPUT)

WHITE W/ BLUE STRIPE

VIOLET

(DIMMING 0-10VDC OUTPUT)

N H

TO VIOLET WIRE ON DIMMING BALLAST

RED

WHITE

BLACK

BLK-120V

ORN-277V

BLK-120V

ORN-277V

BLK-120

V

ORN-277

V

LOAD

LOAD

LOAD

NETWORK

CONTROLLER

ADVANCED W/

HINGED

LOCKING DOOR

SIMILAR TO

LLNC-A-HLD BY

LIGHT LEEDER

DS

NORTH HANGAR

BAY LIGHTING

CONTROLLER

SIMILAR TO

LL-EVO

BY LIGHTLEEDER

P P d E

P P d

WS WALLSTATION WITH SETTINGS: ON/OFF, ALL ZONES,

ZONE 1, ZONE 2, ZONE 3, RAISE LOWER(30-70%)

ALL ZONES

NH-'A'

NH-'B'

NH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

WS WS WS WS

ALL ZONES

NH-'A'

NH-'B'

NH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

ALL ZONES

NH-'A'

NH-'B'

NH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

ALL ZONES

NH-'A'

NH-'B'

NH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

ALL ZONES

SH-'A'

SH-'B'

SH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

WS WS WS WS

ALL ZONES

SH-'A'

SH-'B'

SH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

ALL ZONES

SH-'A'

SH-'B'

SH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

ALL ZONES

SH-'A'

SH-'B'

SH-'C'

DIM/AUTO

RAISE/

LOWER

ON/OFF

NH-'A'

NH-'B'

NH-'C'

CAT-6 DATA CABLE FOR NETWORK SYSTEM

CAT-6 DATA CABLE FOR BUS OF LOCAL CONTROLLER

CAT-6 DATA CABLE FOR BUS OF LOCAL CONTROLLER

SOUTH HANGAR

BAY LIGHTING

CONTROLLER

SIMILAR TO

LL-EVO

BY LIGHTLEEDER

P P

E P

P

NOTES:

QUANTITY OF EACH TYPE OF RELAY, ADDITIONAL POWER SUPPLIES,

NETWORK EQUIPMENT, CONTROL PANELS, AND ANCILLARY

EQUIPMENT SHALL BE AS REQUIRED TO IMPLEMENT THE LIGHTING

CONTROL STRATEGY.

FIELD LOCATE LIGHTING CONTROL PANELS IN ELECTRICAL ROOMS AS

REQUIRED FOR SYSTEM FUNCTIONALITY.

PROVIDE SURGE PROTECTION DEVICES WITH EACH CONTROL PANEL

PROVIDE A CENTRAL INVERTER FOR EMERGENCY POWER TO

HANGAR LIGHTS INDICATED AS EMERGENCY FIXTURES.

1.

2.

3.

P P d E

P P d P

P E

P P

OS

SWc

H N

LOAD

WHITE

BLACK BLACK

B L A

C K

VIOLET & GRAY (0-10V)

DS

DS

OS

NH-'A'

OS

NH-'B'

OS

NH-'C'

DS

NH-'A'

NH-'B'

NH-'C'

DS

DS

OS

NH-'A'

OS

NH-'B'

OS

NH-'C'

OS

DS (WHERE APPLICABLE)

ON/OFF OR

2.

SWc OR SWd (AS REQUIRED BY APPLICATION)

SWa

OS

SWc

4.

BLACK BLACK

GND

VIOLET

GRAY

ROOM NO. DESCRIPTION

104 W&T STORAGE

BLDG-1001

LOCKERS

115 OFFICE

118 EQUIP./HAZMAT STORAGE

118A COLLATERAL STORAGE

ALL INDIVIDUAL

OFFICES UNLESS

OTHERWISE NOTED

OFFICE

LIGHTING CONTROLS

COLLATERAL STORAGE118A

ROOM NO. DESCRIPTION

SWa

SWa

SWa

116A VESTIBULE

APG SUPERVISORS124

ALL CORRIDORS AND

VESTIBULES UNLESS

OTHERWISE NOTED

ALL COMM CLOSETS

UNLESS OTHERWISE

NOTED.

125 TRAINING

RADIO DISPATCH126AALL LOCKER ROOMS

UNLESS OTHERWISE

NOTED

ALL RESTROOMS

UNLESS OTHERWISE

NOTED (ADD. OS'S

MAY BE REQUIRED)

RESTROOMS

BREAKROOM135

159 AVIONICS

ELECTRICAL ROOM163

163 LOCKHEED/PMA STORAGE

169 OVERFLOW STORAGE

176 SUPPORT SHOP

STORAGE171

BREAKROOM170

180 SHOP

181 CORRIDOR

184 BATTERY (CHARGE)

186 BATTERY (STORAGE)

C h a n g e

/1

/2

A m e n d m e n t

/8

/2

PPd

PPd

PPd

NOTES:

IN SPACES WHERE DIFFERENT TYPES OF LIGHTS ARE INSTALLED,

SWITCHES MUST HAVE DISTINCT BUTTONS TO CONTROL LIGHT

GROUPS INDEPENDENTLY.

QUANTITY OF POWER PACKS SHALL BE AS REQUIRED TO CONTROL

LIGHTING WITHIN THE ROOM/AREA.

1.

2.

NOTES:

IN SPACES WHERE DIFFERENT TYPES OF LIGHTS ARE INSTALLED,

SWITCHES MUST HAVE DISTINCT BUTTONS TO CONTROL LIGHT

GROUPS INDEPENDENTLY.

QUANTITY OF POWER PACKS SHALL BE AS REQUIRED TO CONTROL

LIGHTING WITHIN THE ROOM/AREA. QUANTITY OF OS SHALL BE AS

INDICATED ON THE PLANS.

1.

2.

OS

B L A

C K

PPd

NOTES:

IN SPACES WHERE DIFFERENT TYPES OF LIGHTS ARE INSTALLED,

SWITCHES MUST HAVE DISTINCT BUTTONS TO CONTROL LIGHT

GROUPS INDEPENDENTLY.

QUANTITY OF POWER PACKS SHALL BE AS REQUIRED TO CONTROL

LIGHTING WITHIN THE ROOM/AREA. QUANTITY OF OS SHALL BE AS

INDICATED ON THE PLANS.

1.

2.

M

M

MOD

M O

D

STORAGE

106A

EJECTION SEAT

STORAGE

EGRESS OFFICE

OFFICE

MECH

CANOPY SHOP

WOMEN LOCKERS

FLIGHT LINE LO

OFFICE

MECH

COMM

117A

COLLATERAL

STORAGE

118A

EQUIP./HAZMAT

STORAGE

ELEC

N. ENTRY

ELEC

OFFICE

123B

OFFICE

N. VESTIBULE

OFFICE

123C

OFFICE

123A

APG

SUPERVISORS

WHEEL & TIRE

SHOP

W&T STORAGE

CORRIDOR

113A

VESTIBULE

116A

EJECTION SEAT

SHOP

107A

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

+42" +42"

PB1A- 7

PB1A- 7

PB1A- 7

PB1A- 7

PB1A- 7

PB1A- 15 PB1A- 15

PB1A- 15PB1A- 15

PB1A- 8

PB1A- 8

PB1A- 8

PB1A- 8

P B

A

PB1A- 2

PB1A- 2

P B

A

PB1A- 18

PB1A- 18

PB1A- 6

PB1A- 14

PB1A- 4

PB1A- 4

PB1A- 4

PB1A- 4

PB1A- 17

PB1A- 17 PB1A- 17

PB1A- 17PB1A- 17

P B

A

P B

A

PB1A- 19

PB1A- 12

PB1A- 35

PB1A- 20

PB1A- 20

PB1A- 12

P B

A

PB1A- 27

PB1A- 11

PB1A- 11

P B

A

P B

A

PB1A- 12

P B

A

P B

A

P B

A

PB1A- 5

1E- 8

LB1- 8

LB1- 21

LB1- 21

LB1- 21

LB1- 21

LB1- 18

LB1- 18

LB1- 4

LB1- 4

LB1- 4

LB1- 17LB1- 17

LB1- 17

LB1- 25

LB1- 25

LB1- 25

LB1- 25

PB1A- 12

PB1A- 10

PB1A- 10

PB1A- 10

PB1A- 10

PB1A- 29

PB1A- 5

PB1A- 29

1E- 8

LB1- 8

PB1A- 1

LB1- 18

LB1- 17

P B

A

+72"

PB1A- 6 +72"

LB1- 18

LB1- 11

L B

WP/GFCI

W

P /G

F C

I

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

XP

1PB1A- 3

PB1- 24

SEAT TRAILER

SEAT

TRAILER

CANOPY TRAILER

CANOPY TRAILER

XP

XP

PORTABLE

CRANE

PANEL

RACKS

CU-1

DOAS-1

CU-2

AHU-2

EF-1

M

DAC-1

DCU-1

AHU-1

IWH-1

IWH-2

VAV-3-1

NITROGEN

GENERATOR

DS-PWCONV 1

P B

A

PB1A- 17

MEN LOCKERS

CORRIDOR

113A

G F

C I

NORTH HANGAR

BAY

+48"+20"

+48"

PB1A- 16

LB1- 11

PB1A- 30

PB1A- 9

LB1A- 8

PB1A- 23

HB1B- 20,22,24

PANEL 1L

PANEL 1H

1E

HB1A

LB1A

LB1

PB1A

PB1A- 5

HB1B- 1

PB1B- 6,8

PB1B

PB1B- 1,3

IWH-3

IWH-4

HB1B- 9,11,13

PB1A- 21

PB1B- 2,4

HB1B- 21,23,25

HB1B

HB1B- 8,10,12

HB1B- 3,5,7

PB1A- 18

PB1B- 9,11

GFCI

GFCI

G F

C I G

F C

I

WP/GFCI

GFCI

WP/GFCI

W P

/G F

C I

LB1- 11

M

M

ROLLUP DOOR -106 OPERATOR

ROLLUP DOOR -107 OPERATOR

HB1B- 38,40,42

+42"

+42"

HB1B- 32,34,36

PB1A- 28

PB1A- 31

+42"

HB1A- 31,33,35

PB1B- 5,7

60A, 2P

LB1- 27

EWH-1

PB1B- 10

PB1B- 12

PB1B- 13

A

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:1

A

M

E-010

E L E

C T

R

IC

A L P

L A

N

A R

E A

A

M S

M

IT

H

M S

M

IT

H

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

1/8" = 1'-0"1

ELECTRICAL PLAN - AREA A

KEY NOTES:

1. COORDINATE WITH HVAC MECHANICAL

CONTRACTOR FOR INSTALLATION AND POWERING

OF HVAC EQUIPMENT FURNISHED BY THE

MECHANICAL CONTRACTOR. WHERE M-SHEETS DO

NOT INDICATE THE PROVISION OF SWITCHES BY

THE MECHANICAL CONTRACTOR THEY SHALL BE

PROVIDED BY THE ELECTRICAL CONTRACTOR.

2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL

BE GFCI PER NEC 210.8 REQUIREMENTS.

3. WHERE THE STANDARD FUSED SWITCH RATING IS

TOO LARGE FOR ACCOMODATING THE FUSE SIZE

INDICATED , PROVIDE A FUSE ADAPTER KIT.

SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND

APPROVAL WITH FUSES AND SWITCHES.

NOTES:

2-EXPLOSION PROOF RECEPTACLES, COLUMN

MOUNTED. THE BASIS OF DESIGN IS KILLARK

UGR8-20231QW 20A CLASS 1, DIVISION 1.

480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE

4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR

SUPPORT EQUIPMENT.

200A, 3P, 4W BUSDUCT PLUG-IN FUSED DISCONNECT

SWITCH (150 AF) .

REPLACE EXISTING 480/277V 800A BUSWAY "BDTN"

WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW

PLUG IN UNITS, END BOXES, AND ACCESSORIES.

POWER CONVERTER:

INPUT: 480V, 3PH, 4W+G, 90KVA

OUTPUT: 270VDC, 400HZ, AND 28VDC

CABLE HANDLER REEL

ROLLUP DOOR: WIRE PER MANUFACTURER'S

REQUIREMENTS COORDINATE OPERATOR LOCATION

AND MOTOR CONNECTION WITH INSTALLATION OF

DOOR AS REQUIRED.

60A, 240V or 600V RATED, 2-POLE SWITCH

30A, 600V RATED, 3P, 3W+G, NEMA 1 DS

30AS, 15AF, 600V RATED, 3P, 3W+G, NEMA 1 DS

60AS, 35AF 600V RATED, 3P, 3W+G, NEMA 3R DS

30AS, 30AF 208 OR 240V RATED, 2P, 2W+G, NEMA 3R DS

INDOOR UNIT WIRED TO OUTDOOR UNIT IN

ACCORDANCE WITH MANUFACTURER REQUIREMENTS.

COORDINATE WITH ARCHITECTURAL AND FIRE ALARM

FOR POWERING DOOR HOLD OPEN DEVICES.

RELOCATE EXISTING EM. SHOWER ALARM CIRCUIT TO

NEW SHOW LOCATION.

60AS, 50AF, 240V RATED, 2P, 2W+G, NEMA 12

60AS, 40AF, 600V RATED, 3P, 3W+G, NEMA 3R

30AS, 25AF, 600V RATED, 3P, 3W+G, NEMA 3R

30AS, 15AF, 600V RATED, 3P, 3W+G, NEMA 3R

SCALE:

4' 8' 16'0

1/8" = 1'-0"

A m e n d m e n t

/8

/2

W

WD

S

FATR

CC

CC

S

FATR

M

M

M

M

M

M

M

M

M

M

M

M

MM

M

M

M

M

M

MOD MOD

READY ROOM

MENS LOCKERS

MECH

127B

OFFICE

CORRIDOR

OFFICE

BREAK ROOM

ELEVATOR

ELECTRICAL

PILOT DEBRIEF

MULTIPURPOSE

ROOM

STAIRS

ELEC

139A

OFFICE

LOCKHEED

LOCKHEED

MEN RESTROOMS

WOMEN

RESTROOMS

CORRIDOR

LACTATION ROOM

ELECTRICAL

MECHANICAL

NORTH HANGAR

BAY

VESTIBULE

127A

CORRIDOR

131A

CORRIDOR

131D

VESTIBULE

143B

VESTIBULE

131B

VESTIBULE

131C

WOMEN LOCKERS

CORRIDOR

143A

LA1

PANEL HA1

+42"

+42"

+42"

+42"

+42"

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

PANEL HC1

PANEL LC1

+42"

LB1A- 11

LB1A- 11

LB1A- 11

LB1- 30

LB1- 30

LB1- 30

L B

LB1- 16

LB1- 37

LB1- 37

LB1- 37

L B

L B

L B

L B

L B

LB1- 39

LB1- 39

LB1- 39

LB1- 10

LB1- 23

LB1- 23

LB1- 23

LB1- 19

LB1- 19

LB1- 12

LB1- 12

LB1- 12

LB1- 13

LB1- 13

LA1- 9

LB1- 12

LB1- 12

LC1- 28

LC1- 28

LC1- 30LC1- 30

LC1- 38

LC1- 1

LC1- 26

LC1- 26

LC1- 25 LC1- 25

LC1- 25

LC1- 24

LC1- 24

LC1- 24

L C

L C

LC1- 34 LC1- 34

LC1- 22

LC1- 22

LC1- 11

LC1- 11

LC1- 7

LC1- 18

LC1- 18

LC1- 1

LC1- 17 LC1- 17

LC1- 17

LC1- 17

LC1- 3LC1- 3 LC1- 21

LC1- 21

LB1- 14

LB1- 14

LB1- 14

LB1- 14

TRAINING

RADIO DISPATCH

126A

OFFICE

VESTIBULE

125A

DIST C MAIN C TIE MAIN B DIST B

SWBD2

120/208

DIST

SWBD2 - 120/208

MAIN SWBD 480/277

LB1- 30

LB1A- 11

LB1- 23

LB1- 19

LB1- 19

LB1- 13 LB1- 13

LB1- 15

LB1- 15

LB1- 7

LB1- 16

LC1- 28

LC1- 28LC1- 28

LC1- 30

LC1- 30

LC1- 30

LC1- 26 LC1- 26

LC1- 26

LC1- 18

LC1- 5 LC1- 24

LC1- 38

LC1- 38

LC1- 1

+42"

LC1- 10

LC1- 2

LC1- 6

LC1- 32

L C

LC1- 19

LC1- 19

LC1- 19

LC1- 17

LC1- 3

LC1- 3LC1- 3

LC1- 21

LC1- 21

LC1- 21

LC1- 9

LB1- 16

LC1- 32

SPD

480V TERMINAL BOX

PANEL 1DP

PANEL EDP1

PANEL EDP2

SWBD MTS

PANEL IQ

PANEL 1C

PANEL 1F

PANEL 1M

PANEL 1P

APRON CONTROL PANEL

PANEL 1J

LC1- 7

LC1- 7

LC1- 11

LC1- 13

L C

L C

+72"

+72"

LB1- 10

+42"

" +72"

GFCI G

F

C I

GFCI

GFCI

GFCI

GFCI

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

XP

XP

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

PB1A- 3 PB1A- 3

PB1 - 25 PB1 - 26

PANEL

RACKS

PANEL

RACKS

LC1- 5

LC1- 5

+72"

+72"

LC1- 19

FACU

PANEL

RACKS

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

VAV-3-7

VAV-3-8

VAV-3-9

VAV-3-6

VAV-3-4

VAV-3-2

VAV-3-3

VAV-3-5 EF-3

VAV-4-8

VAV-4-9

AHU-3

VAV-4-1

VAV-4-6

VAV-4-7

EF

M

AHU-E

AHU-F

DS-PWCONV 2

DS-PWCONV 3

VAV-4-3

VAV-4-4

LC1- 17

+42"

G F

C I

G F

C I

L B

A

L B

A

LC1- 19

T

LC1- 24

LC1- 8

LC1- 4

LC1- 26

LC1- 19

LB1- 3

HB1B- 2,4,6

LA1- 17

LA1- 15

LA1- 23

LA1- 25

LB1A- 15

VAV-4-2

VAV-4-5

CU-7

EF-2

LA1- 34,36

GFCI

GFCI

GFCI

LC1- 2

GFCI

G F

C I

GFCI

IWH-5

IWH-6

HA1B

+42"

+42"

+42"

+42"

HB1B- 27,29,31

HB1A- 37,39,41

LA1- 5

GFCI

LA1- 7

GFCI

GFCI

GFCI

GFCI

LA1- 9 JANITOR

147B

LB1A- 10,12

PANEL 1F- 22,24

60A

LC1- 15

LC1- 16

LB1A- 14

120V

CTRLS

AHU-7

6 6

AKP-1

AKP-1

LA1- 1 LA1- 3

GFCI

B

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:4

A

M

E-011

E L E

C T

R

IC

A L P

L A

N

A R

E A

B

M S

M

IT

H

M S

M

IT

H

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

1/8" = 1'-0"1

ELECTRICAL PLAN - AREA B

SCALE:

4' 8' 16'0

1/8" = 1'-0"

2-EXPLOSION PROOF RECEPTACLES, COLUMN

MOUNTED. THE BASIS OF DESIGN IS KILLARK

UGR8-20231QW 20A CLASS 1, DIVISION 1.

480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE

4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR

SUPPORT EQUIPMENT.

INSTALL TWO QUADRUPLEX RECEPTACLES AT THIS

LOCATION.

NOT USED.

PROVIDE 3 GANG RECESS FLOOR BOX SIMILAR TO

WIREMOLD EVOLUTION SERIES OR APPROVED EQUAL

WITH (1) DUPLEX RECEPTACLE IN 3/4"C, (1) GANG FOR

DATA IN 1-1/4"C, (1) GANG FOR AV IN 1-1/2"C. CONDUITS

SHALL BE ROUTED TO NEAREST WALL AND ABOVE

CEILING. REFER TO ARCHITECTURAL FOR EXACT

LOCATION AND OTHER REQUIREMENTS.

200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH

200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH

RELOCATE PANEL IQ.

REPLACE EXISTING 480/277V 800A BUSWAY "BDTN"

WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW

PLUG IN UNITS, END BOXES, AND ACCESSORIES.

REPLACE EXISTING 480/277V 800A BUSWAY "BDTS"

WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW

PLUG IN UNITS, END BOXES, AND ACCESSORIES. BUS

DUCT AND ACCESSORIES SHALL BE RATED MIN IP54

AND ACCEPTABLE FOR USE IN HUMID ENVIRONMENT.

POWER CONVERTER:

INPUT: 480V, 3PH, 4W+G, 90KVA

OUTPUT: 270VDC, 400HZ, AND 28VDC

CABLE HANDLER REEL

60A, 240V or 600V, 2-POLE SWITCH

30AS, 15AF, 600V, 3P, 3W+G, NEMA 1, DS

30A, 208 OR 240V RATED, 2P, 2W+G, NEMA 1(INDOOR

LOCATION) NEMA 3R (OUTDOOR LOCATION), DS

PROVIDE ADDITIONAL JBOXES, AND SPLICING

HARDWARE, AND APPURTENANCES AS REQUIRED TO

FACILITATE INSTALLATION OF MULTIPLE UNITS OF

EQUIPMENT ON THE SAME CIRCUIT. NOTE THAT

INDIVIDUAL SWITCHES MAY NOT BE RATED FOR FULL

CAPACITY OF LOADS.

30AS, 600V RATED, 3P, 3W+G, NEMA 1 DS

KEY NOTES:

1. COORDINATE WITH HVAC MECHANICAL

CONTRACTOR FOR INSTALLATION AND POWERING

OF HVAC EQUIPMENT FURNISHED BY THE

MECHANICAL CONTRACTOR. WHERE M-SHEETS DO

NOT INDICATE THE PROVISION OF SWITCHES BY

THE MECHANICAL CONTRACTOR THEY SHALL BE

PROVIDED BY THE ELECTRICAL CONTRACTOR.

2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL

BE GFCI PER NEC 210.8 REQUIREMENTS.

3. WHERE THE STANDARD FUSED SWITCH RATING IS

TOO LARGE FOR ACCOMODATING THE FUSE SIZE

INDICATED , PROVIDE A FUSE ADAPTER KIT.

SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND

APPROVAL WITH FUSES AND SWITCHES.

NOTES:

1112 1112

A m e n d m e n t

/8

/2

S

CC C

S

M

MMOD

COMPUTER AREA

SECURE ROOM

OFFICE

OFFICE

BREAK ROOM

AVIONICS

LOCKHEED

WOMEN LOCKERS

MEN LOCKERS

ELEC

S. ENTRY

S. VESTIBULE

SOUTH HANGAR

BAY

VESTIBULE

159A

+42"

+42"

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

T P

T P

T P

T P

T P

T P

TP2- 29

TP2- 34

T P

TP2- 28

TP2- 28

TP2- 28

TP2- 28 TP2- 30

TP2- 30

TP2- 30

TP2- 30

TP2- 29

TP2- 29

T P

T P

2TP2- 31

TP2- 31

TP2- 36

TP2- 36

T P

TP2- 33

TP2- 33

TP2- 38

TP2- 38

TP2- 38

TP2- 38

LD1A- 16

LD1A- 16

TP2- 40

TP2- 40

TP2- 40

TP2- 40

VESTIBULE

152A

TP2- 29

TP2- 29

TP2- 34

+42"

T P

LD1A- 5

+72"

XP

XP

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

XP

LC1- 23 LC1- 23 LE1- 29

LE1- 31LC1- 35LC1- 33

X

PANEL

RACKS

PANEL

RACKS

NOT IN SCOPE

VAV-5-1

CU-5

AHU-5

EF-4

VAV-5-6

VAV-5-7

VAV-5-4

VAV-5-3

VAV-5-2

DS-PWCONV 5

4 5

PANEL HA1-

8,10,12

1-D

1G

PANEL HA1-

38,40,42

TP2

TP2- 16

+42"

T P

T

DS-PWCONV 4

IWH-7

HA1B- 1

HA1B- 3

+42" +42" +42"

+42"

G F

C I

G F

C I

G F

C I

GFCI

GFCI

HB1B- 33,35,37

HB1A- 12,14,16

T P

,4

60AS

60AS 60AS

60AS

TP2- 45

EWH-2

NAC

PANEL X- 9

120V

CONTROL

CKT

+42"

4 4 4

+42"

2 2

VAV-5-5

C

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:5

A

M

E-012

E L E

C T

R

IC

A L P

L A

N

A R

E A

C

M S

M

IT

H

M S

M

IT

H

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

1/8" = 1'-0"1

ELECTRICAL PLAN - AREA C

SCALE:

4' 8' 16'0

1/8" = 1'-0"

2-EXPLOSION PROOF RECEPTACLES, COLUMN

MOUNTED. THE BASIS OF DESIGN IS KILLARK

UGR8-20231QW 20A CLASS 1, DIVISION 1.

480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE

4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR

SUPPORT EQUIPMENT.

ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL BE

GFCI PER NEC 210.8 REQUIREMENTS.

200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH

200AS/150AF, 3P, 4W BUS PLUG DISCONNECT SWITCH

THAT CORRESPONDS TO DS-PWCONV 5

REPLACE EXISTING 480/277V 800A BUSWAY "BDTS"

WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW

PLUG IN UNITS, END BOXES, AND ACCESSORIES. BUS

DUCT AND ACCESSORIES SHALL BE RATED MIN IP54

AND ACCEPTABLE FOR USE IN HUMID ENVIRONMENT.

POWER CONVERTER:

INPUT: 480V, 3PH, 4W+G, 90KVA

OUTPUT: 270VDC, 400HZ, AND 28VDC

CABLE HANDLER REEL

60A, 240V or 600V, 2-POLE SWITCH

60AS, 30AF, 600V RATED, 3P, 3W+G, NEMA 1, SW

HVAC UNIT IS LOCATED ON THE 2ND LEVEL.

WIRE 120V CONTROLS CKT TO 2ND LEVEL

PANELBOARD, 3/4"C., 2#12, 1#12G, 20A CB. DOCUMENT

FOR RECORD DRAWINGS.

PROVIDE ADDITIONAL JBOXES, AND SPLICING

HARDWARE, AND APPURTENANCES AS REQUIRED TO

FACILITATE INSTALLATION OF MULTIPLE UNITS OF

EQUIPMENT ON THE SAME CIRCUIT. NOTE THAT

INDIVIDUAL SWITCHES MAY NOT BE RATED FOR FULL

CAPACITY OF LOADS.

60AS, 15AF, 600V RATED, 2P, 2W+G, NEMA 1 SW

60AS, 20AF, 600V RATED, 2P, 2W+G, NEMA 1 SW

60AS, 7AF, 600V RATED, 2P, 2W+G, NEMA 1 SW

60AS, 5AF, 600V RATED, 2P, 2W+G, NEMA 1 SW

30AS,15AF, 600V RATED, 3P, 3W+G, NEMA 1 SW

KEY NOTES:

1. COORDINATE WITH HVAC MECHANICAL

CONTRACTOR FOR INSTALLATION AND POWERING

OF HVAC EQUIPMENT FURNISHED BY THE

MECHANICAL CONTRACTOR. WHERE M-SHEETS DO

NOT INDICATE THE PROVISION OF SWITCHES BY

THE MECHANICAL CONTRACTOR THEY SHALL BE

PROVIDED BY THE ELECTRICAL CONTRACTOR.

2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL

BE GFCI PER NEC 210.8 REQUIREMENTS.

3. WHERE THE STANDARD FUSED SWITCH RATING IS

TOO LARGE FOR ACCOMODATING THE FUSE SIZE

INDICATED , PROVIDE A FUSE ADAPTER KIT.

SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND

APPROVAL WITH FUSES AND SWITCHES.

NOTES:

8 78 7

A m e n d m e n t

/8

/2

M

M

M

MOD MOD

M O

D

LOCKHEED / PMA

STORAGE

COMM

OVERFLOW

STORAGE

BREAK ROOM

LOCKHEED

OFFICE

OFFICE

SUPPORT SHOP

SHOP

MECH

WOMEN

RESTROOM

MEN RESTROOM

BATTERY

(CHARGE)

BATTERY

(STORAGE)

CORRIDOR

HEF

STORAGE

VESTIBULE

176A

STORAGE

VESTIBULE

169A

PANEL HE1

PANEL LE1

+42"

+42"

+40"

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N +40"

LD1A- 8

LD1A- 9

LD1A- 9

LD1A- 10

L D

A

LD1A- 27 LD1A- 17

LD1A- 17

LD1A- 4

L D

A

LD1A- 7

LE2- 1LE2- 1

LE1- 17

LE1- 11

LE1- 12

LE1- 16

LE1- 33

LD1A- 2

LD1A- 2

LD1A- 2

LD1A- 2

L D

A

LD1A- 7

LD1A- 7 LD1A- 7

LD1A- 11

LD1A- 11

LE1- 13LE1- 13

LE1- 5

LE1- 7

LE1- 7

LE1- 5

LE1- 7

LE1- 5

LE2- 2

LE2- 2

LE1- 11

LE1- 11

LE1- 17

LE1- 17

LE1- 17

LE1- 19

LE1- 19

LE1- 19

LE1- 14

LE1- 14

LE1- 14

LE1- 16 LE1- 12

LE1- 35

LE1- 37

GOVERNMENT

FURNISHED

CONTRACTOR

INSTALLED

XP

LE1- 29

LE1- 32

LD1A- 32

LD1A- 10

L D

A

LD1A- 8

DCU-4 DCU-3 WAC-1

DOAS-2

CU-6

NOT IN

SCOPE

NOT IN SCOPE

AHU-6

VAV-6-9

VAV-6-8

EF-6

VAV-6-6 VAV-6-5

VAV-6-4

VAV-6-3

VAV-6-2

VAV-6-1

DCU-2

EF-5

IWH-9

IWH-8

WP

GFCI

DS-PWCONV 6

VAV-6-7

LD1A

+42"

+48"

+48"

+48"

+48" +48"+36"

+48"+36"

+48" +36"

DAC-2

DAC-3

DAC-4

HE1- 33

HE1- 30

HE1- 32

HE1- 14

HE1- 16

LD1A- 11

LD1A- 10

LD1A- 32

LD1A- 34

HE1- 32

LD1A- 8

LE1- 16

LE1- 4,6 LE1- 34,36

HE1- 21,23,25

HE1- 27,29,31

HE1- 15,17,19

HE1- 24,26,28

LD1A- 4

LE1- 13

LD1A- 27

LD1A- 17

L D

A

LD1A- 2

LE1- 8

LE2

15KVA

480V-240/120V

T

LD1A- 13,15

GFCI

G F

C I

G F

C I

G F

C I

IW

H

-1

HE1- 34,36,38

HE1- 3,5,7

PLUG-IN UNIT FOR

XFMR-LE2

XFMR-LE2

LD1A- 24+48" +36"

+20"

LD1A- 6

LD1A- 18

LD1A- 20

LD1A- 21

LD1A- 23

LD1A- 22

+20"

+20"

LD1A- 25

LD1A- 29

LD1A- 31 +20"

LE1- 28

LE1- 10

LE1- 9

+48"

+36" +20"

LE1- 25

LE1- 23

LE1- 21

LD1A- 33,35

LE1- 27

AIS-1 HP1

LE1- 15

LE2-3,5

+42"

LE1- 1

LD1A- 19

LD1A- 12

100AS/40AF, 2P, 600V

100AS/40AF,

2P, 600V

KEY PLAN

D

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:0

A

M

E-013

E L E

C T

R

IC

A L P

L A

N

A R

E A

D

M S

M

IT

H

M S

M

IT

H

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

SCALE:

4' 8' 16'0

1/8" = 1'-0" 1/8" = 1'-0"1

ELECTRICAL PLAN - AREA D

2-EXPLOSION PROOF RECEPTACLES, COLUMN

MOUNTED. THE BASIS OF DESIGN IS KILLARK

UGR8-20231QW 20A CLASS 1, DIVISION 1.

480V, 3PH, 4W+G, 150A RECEPTACLE, WITH NEMA SIZE

4 STARTER IN NEMA 4X 316 SS ENCLOSURE; FOR

SUPPORT EQUIPMENT.

200A, 3P, 4W BUS PLUG DISCONNECT SWITCH THAT

CORRESPONDS TO DS-PWCONV 6

REPLACE EXISTING 480/277V 800A BUSWAY "BDTS"

WITH NEW 480/277V, 800A COPPER BUSWAY AND NEW

PLUG IN UNITS, END BOXES, AND ACCESSORIES. BUS

DUCT AND ACCESSORIES SHALL BE RATED MIN IP54

AND ACCEPTABLE FOR USE IN HUMID ENVIRONMENT.

POWER CONVERTER:

INPUT: 480V, 3PH, 4W+G, 90KVA

OUTPUT: 270VDC, 400HZ, AND 28VDC

CABLE HANDLER REEL

60A, 240V or 600V, 2-POLE SWITCH

60A, 600V RATED, 3P,3W+G, NEMA 1

60AS, 40AF 600V RATED, 3P,3W+G, NEMA 3R

30A, 208/240V RATED, 2P, 2W+G, NEMA 3R SW

INDOOR UNIT WIRED TO OUTDOOR UNIT IN

ACCORDANCE WITH MANUFACTURER REQUIREMENTS.

30AS, 20AF, 600V RATED, 3P, 3W+G, NEMA 3R SW

40A, 600V RATED, TOGGLE SWITCH, NEMA 1 SW

20A, 277V RATED, TOGGLE SWITCH, NEMA 1 SW

PROVIDE ADDITIONAL JBOXES, AND SPLICING

HARDWARE, AND APPURTENANCES AS REQUIRED TO

FACILITATE INSTALLATION OF MULTIPLE UNITS OF

EQUIPMENT ON THE SAME CIRCUIT. NOTE THAT

INDIVIDUAL SWITCHES MAY NOT BE RATED FOR FULL

CAPACITY OF LOADS.

240V LASER ETCHER RECEPTACLE. COORDINATE WITH

OWNER FOR RECPTACLE TYPE.

30AS/15AF, 3P, 3P,3W+G,600V,NEMA 3R SW FOR CABLE

REEL CIRCUIT (3/4"C. 3#12,1#12G).

60AS, 30AF, 600V RATE, 2P, 2W+G, NEMA 1 SW

60AS, 10AF, 600V RATE, 2P, 2W+G, NEMA 1 SW

60AS, 50AF, 600V RATE, 2P, 2W+G, NEMA 1 SW

KEY NOTES:

1. COORDINATE WITH HVAC MECHANICAL

CONTRACTOR FOR INSTALLATION AND POWERING

OF HVAC EQUIPMENT FURNISHED BY THE

MECHANICAL CONTRACTOR. WHERE M-SHEETS DO

NOT INDICATE THE PROVISION OF SWITCHES BY

THE MECHANICAL CONTRACTOR THEY SHALL BE

PROVIDED BY THE ELECTRICAL CONTRACTOR.

2. ALL RECEPTACLES WITHIN 6' OF THE SINK SHALL

BE GFCI PER NEC 210.8 REQUIREMENTS.

3. WHERE THE STANDARD FUSED SWITCH RATING IS

TOO LARGE FOR ACCOMODATING THE FUSE SIZE

INDICATED , PROVIDE A FUSE ADAPTER KIT.

SUBMIT THE FUSE ADAPTER KIT FOR REVIEW AND

APPROVAL WITH FUSES AND SWITCHES.

NOTES:

12 9

15 16

A m e n d m e n t

/8

/2

AHU-4

PANEL HA1-

37,39,41

PANEL 1F- 7

PANEL 1F- 26

120V

CTRL

CKT

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:0

:4

A

M

E-014

E L E

C T

R

IC

A L P

L A

N

M E

Z Z

A N

IN

E

O C

R U

Z

A u th o r

C h e c k e r

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

SCALE:

2' 4' 8'0

1/4" = 1'-0"

1/4" = 1'-0"1

ELECTRICAL PLAN - MEZZANINE

KEY NOTES:

1. COORDINATE WITH HVAC MECHANICAL

CONTRACTOR FOR INSTALLATION AND POWERING

OF EQUIPMENT FURNISHED BY THE MECHANICAL

CONTRACTOR.

NOTES:

30AS/15AF, 600V, 3P, 3W+G, NEMA 3R, DS

A m e n d m e n t

/8

/2

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

WS

WS

OS

OS

OS

OS

PORTABLE

CRANE

PANEL

RACKS

STORAGE

106A

EJECTION SEAT

STORAGE

EGRESS OFFICE

OFFICE

MECH

CANOPY SHOP

MEN LOCKERS

WOMEN LOCKERS

FLIGHT LINE LO

OFFICE

MECH

COMM

117A

COLLATERAL

STORAGE

118A

EQUIP./HAZMAT

STORAGE

ELEC

N. ENTRY

ELEC

OFFICE

123B

OFFICE

N. VESTIBULE

OFFICE

123C

OFFICE

123A

APG

SUPERVISORS

WHEEL & TIRE

SHOP

W&T STORAGE

CORRIDOR

113A VESTIBULE

116A

EJECTION SEAT

SHOP

107A

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

G

G

G

G

G1

G1

G G1

B

W

D1 D

D D1

K

K

C1 C

E1

E

D1 D

D1

D

D1

D

C1 C

D

D1

D

D D1

K

B

Y

J1

J1

F1

F1

F

D D D D

K

D1 D D1 D

D D1

D1

F F

F1 F

F1

F

F1

GG

G1

G

G

G

G

G1

G1G

K1

V1

A

A1

A1

A

A1

A1

A

A

A1

A

K1

K

EX

EX1

EX1

EX

EX1

EX1

EX1

EX1

EX1

EX1

EX1

V1

EX1

B1

K1

C C1C

C1 CC

C1

EX

B1

EX1

EX1

A

A

A1

A

A

X

D

X

K

HB1A- 8

FIXTURE TYPE 'B' & 'B1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'C' & 'C1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'F' & 'F1'

PENDANT MTD

10'-0" AFF (TYP)

FIXTURE TYPE 'D' & 'D1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'K' & ' K1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'G' & ' G1'

PENDANT MTD 6'-9"AFF

(TYP FOR THIS ROOM)

FIXTURE TYPE 'G' & ' G1'

PENDANT MTD 8'-0" AFF

(TYP FOR THIS ROOM)

FIXTURE TYPE 'J1'

PENDANT MTD

10'-0" AFF (TYP)

FIXTURE TYPE 'E' & 'E1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'A' & 'A1'

PENDANT MTD

20'-0" AFF (TYP)

FIXTURE TYPE 'V1'

SURFACE MTD

AFF (TYP)

FIXTURE TYPE 'M'

SURFACE MTD

AFF (TYP)

FIXTURE TYPE 'K' & 'K1'

SURFACE MTD

AFF (TYP)

HB1A- 7 HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7HB1A- 7

HB1A- 7 HB1A- 7

HB1A- 7HB1A- 7

HB1A- 7 HB1A- 7

HB1A- 7HB1A- 7

HB1A- 7 HB1A- 7

HB1A- 7HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7 HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 7 HB1A- 7 HB1A- 7

HB1A- 7HB1A- 7HB1A- 7

HB1A- 7 HB1A- 7 HB1A- 7

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 7 HB1A- 7

HB1A- 7

HB1A- 7

HB1A- 8

HB1A- 8

HB1A- 8 HB1A- 8 HB1A- 8 HB1A- 8

HB1A- 8 HB1A- 8 HB1A- 8

HB1A- 8

HB1A- 8HB1A- 8

HB1A- 8

HB1A- 8 HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

FIXTURE TYPE 'EX'

WALL MTD

6" ABOVE DOOR

(TYP, SEE NOTE 1)

FIXTURE TYPE 'EX1'

CEILING MTD

(TYP, SEE NOTE 1)

FIXTURE TYPE 'X'

JOIST MTD., 200' REEL

20'-0" AFF (TYP)

FIXTURE TYPE 'W'

SURFACE MTD

AFF (TYP)

FIXTURE TYPE 'Y'

PENDANT MTD

10'-0" AFF

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8

HB1A- 8 HB1A- 8

HB1A- 8

HB1A- 8

LA2- 2

LA2- 2

HA2- 1 HA2- 1 HA2- 1

HA2- 1 HA2- 1 HA2- 1

HA2- 3HA2- 3HA2- 3

HA2- 3 HA2- 3 HA2- 3

HA2- 5HA2- 5HA2- 5

EM

Z

HB1A- 8

P P

V1

K

HB1A- 8

K1 HB1A- 8 K

HB1A- 8

HB1A- 8

HB1A- 8

M

HB1A- 8

M

HB1A- 8

HB1A- 8

FIXTURE TYPE 'P'

SURFACE MTD

AFF (TYP)

A1 HA2- 1

EX1

HB1A- 7

HB1A- 8P

EX

HB1A- 7

HB1A- 7

EX1

HB1A- 7

EX

HB1A- 8

Z

Z2

Z2

+10'4"

+13'8"

+10'4"

+10'6"

NH

NH

CANOPY TRAILER

CANOPY TRAILER

DS

1 1

EX1

HB1A- 7 1

A

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:0

A

M

E-015

L

IG

H T

IN

G

P L A

N

A R

E A

A

R R

U C

K

R R

U C

K

B P

E T

T

IF

O R

D

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

SCALE:

4' 8' 16'0

1/8" = 1'-0"

1/8" = 1'-0"2

LIGHTING PLAN - AREA A

1. EXIT SIGNS AND EMERGENCY EGRESS LIGHTS

SHALL BE WIRED TO THE NORMAL LIGHTING

CIRCUIT OF THE ROOM IT SERVES AND TO THE

LINE-SIDE OF THE LIGHT SWITCH.

2. REEL LIGHTS ARE INTENDED TO REPLACE

EXISTING. FIELD LOCATE EXISTING REEL LIGHTS

FOR REPLACEMENT WITH NEW. REEL LIGHTS

SHALL BE INSTALLED IN LOCATIONS CLOSE TO

STIFFENED TRUSS JOINTS.

3. CIRCUIT NEW OUTDOOR LIGHTS TO EXISTING

OUTDOOR LIGHTING CIRCUITS. 3/4"C., 2#8,1#8G

UNLESS OTHERWISE INDICATED.

4. REFER TO SHEETS E-008 AND E-009 FOR

ADDITIONAL LIGHTING CONTROLS REQUIREMENTS.

NOTE:

LIGHTING ZONE 'NH-A' LIGHTING ZONE 'NH-B'

KEY NOTES:

LIGHTING SCENE WALL STATION FOR LIGHTING ZONES

IN NORTH HANGAR 'NH' (NH-A THROUGH NH-C)

2 REPLACE EXISTING ARCHITECTURAL INDIRECT

WALLMOUNT SCONCES WITH NEW LED WALLMOUNT

SCONCES IN VESTIBULE.

C h a n g e

/1

/2

A m e n d m e n t

/8

/2

OS

OS OS OS

OS

OS

OS

OS

OS

OS

OS OS

OS OS

OS OS

OS

OS OS

OS

OS

W S

W S

WS

OS

OS

OS

LOCKHEED / PMA

STORAGE

COMM

OVERFLOW

STORAGE

BREAK ROOM

LOCKHEED

OFFICE

OFFICE

SUPPORT SHOP

SHOP

MECH

WOMEN

RESTROOM

MEN RESTROOM

BATTERY

(CHARGE)

BATTERY

(STORAGE)

CORRIDOR

HEF

STORAGE

VESTIBULE

176A

STORAGE

VESTIBULE

169A

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

NOT IN

SCOPE

NOT IN SCOPE

B

B1

B

B1

K

D

D1

D1

D

E1

E

D

D1

D

D

D1

D

B

B1

C1 C D D1

C

C1

C C

C C1 C

C1 C C

C C C1

U

M

M

M

R

M

M

K

K1

K1

M

L

L

K

K1

K1

F1

F

F1

F

F

F

F1

F1

F

B

K1

K1

H

H1

F F1

F

F

F1

F

F1

F

F1

F

F

K

K

K1 K K K

A

EX1

EX1

EX

EX1

EX1

EX1

EX1

EX

EX

EX

EX

EM

A1

A

A

A1

A

A

A

A1

A

A

A1

X

FIXTURE TYPE 'B' & 'B1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'E' & 'E1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'F' & 'F1'

PENDANT MTD

10'-0" AFF (TYP)

FIXTURE TYPE 'C' & 'C1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'D' & 'D1'

CEILING MTD

AFF (TYP)

FIXTURE TYPE 'N'

PENDANT MTD

10'-0" AFF (TYP)

FIXTURE TYPE 'K' & 'K1'

SURFACE MTD

AFF (TYP)

FIXTURE TYPE 'L''

SURFACE MTD

AFF (TYP)

FIXTURE TYPE 'A' & 'A1'

PENDANT MTD

20'-0" AFF (TYP)

FIXTURE TYPE 'EX1'

CEILING MTD AFF

(TYP, SEE NOTE 1)

FIXTURE TYPE 'EX'

WALL MTD

6" ABOVE DOOR AFF

(TYP, SEE NOTE 1)

FIXTURE TYPE 'EX'

WALL MTD

6" ABOVE DOOR AFF

(TYP, SEE NOTE 1)

FIXTURE TYPE 'X'

PENDANT MTD

20'-0" AFF (TYP)

FIXTURE TYPE 'EM'

WALL MTD 8'-6" AFF

(TYP, SEE NOTE 1)

HE1- 2

HE1- 2

HE1- 2

HE1- 2

HE1- 2

HE1- 2 HE1- 2

HE1- 2HE1- 2

HE1- 2 HE1- 2

HE1- 2

HE1- 2

HE1- 2

HE1- 2

HE1- 2

HE1- 2 HE1- 2 HE1- 1 HE1- 1

HE1- 1

HE1- 1

HE1- 1 HE1- 1

HE1- 4 HE1- 4 HE1- 4

HE1- 4HE1- 4HE1- 4

HE1- 4 HE1- 4 HE1- 4

HE1- 4HE1- 4HE1- 4

HE1- 4

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 4

HE1- 4

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1 HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1 HE1- 1 HE1- 1

HE1- 1HE1- 1HE1- 1

HE1- 1 HE1- 1 HE1- 1

HE1- 1 HE1- 1 HE1- 1

HE1- 1

HE1- 1

HE1- 1 HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1 HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 1

HE1- 2

HE1- 2

Z

HE1- 1

H E

EX1

HA2- 7 HA2- 7

HA2- 7 HA2- 7

HA2- 9 HA2- 9

HA2- 9 HA2- 9

HA2- 11 HA2- 11

HA2- 7 HA2- 7

HE1- 1

DS

KEY PLAN

D

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:1

A

M

E-018

L

IG

H T

IN

G

P L A

N

A R

E A

D

R R

U C

K

R R

U C

K

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

SCALE:

4' 8' 16'0

1/8" = 1'-0" 1/8" = 1'-0"1

LIGHTING PLAN - AREA D

1. EXIT SIGNS AND EMERGENCY EGRESS LIGHTS

SHALL BE WIRED TO THE NORMAL LIGHTING

CIRCUIT OF THE ROOM IT SERVES AND TO THE

LINE-SIDE OF THE LIGHT SWITCH.

2. REEL LIGHTS ARE INTENDED TO REPLACE

EXISTING. FIELD LOCATE EXISTING REEL LIGHTS

FOR REPLACEMENT WITH NEW. REEL LIGHTS

SHALL BE INSTALLED IN LOCATIONS CLOSE TO

STIFFENED TRUSS JOINTS.

3. REFER TO SHEETS E-008 AND E-009 FOR

ADDITIONAL LIGHTING CONTROLS REQUIREMENTS.

NOTE:

LIGHTING ZONE 'SH-A'

KEY NOTES:

1 LIGHTING SCENE WALL STATION FOR LIGHTING ZONES

IN NORTH HANGAR 'SH' (SH-A THROUGH SH-C)

C h a n g e

/1

/2

A m e n d m e n t

/8

/2

W

WD

S

FATR

S

FATR

TRAINING

RADIO DISPATCH

126A

OFFICE

READY ROOM

NORTH HANGAR

BAY

VESTIBULE

125A

M A

T C

H L

IN

E

S

E E

S H

E E

T E

-0 F

O R

C O

N T

IN

U

A T

IO

N

GND-001

GND-002

PANEL LA1

PANEL HA1

PANEL HC1

PANEL LC1

DIST C MAIN C TIE MAIN B DIST B

SWBD2

120/208

DIST

MAIN SWBD 480/277

SPD

480V TERMINAL BOX

PANEL 1DP

PANEL EDP1

PANEL EDP2

SWBD DISCONNECT SWITCH

PANEL IQ

PANEL 1C

PANEL 1F

PANEL 1M

PANEL 1P

APRON CONTROL PANEL

PANEL 1J

2 2

3 3

ELECTRICAL

MECHANICAL

EX. MAIN GND BUS

B

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:1

A

M

E-020

G R

O U

N D

IN

G

S Y

S T

E M

S M

O D

IF

IC

A T

IO

N

A

R E

A B

M S

M

IT

H

M S

M

IT

H

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

1/8" = 1'-0"1

GROUNDING SYSTEMS MODIFICATION -

AREA B

KEY NOTES:

COPPER GROUND BAR (SEE DETAIL E, SHEET E-034)

EXISTING LOOP STYLE GROUND RECEPTACLE

EXISTING STUD STYLE GROUND RECEPTACLE

4 1"C., 1#4/0 BARE COPPER GROUND TO

MAIN ELECTRICAL GND BUS LOCATED IN

ROOM

5 1#4/0 BARE COPPER GROUND

A m e n d m e n t

/8

/2

SCALE:

4' 8' 16'0

1/8" = 1'-0"

3 3

GND-032

GND-033

A

KEY PLAN

TR

U E N

PLAN

NORTH

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

M W

A

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1

F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F L A

N G

H a n g a r_ E

L E

C v

.r v t

/2

/2

:1

:2

A

M

E-022

G R

O U

N D

IN

G

S Y

S T

E M

S M

O D

IF

IC

A T

IO

N

A

R E

A D

M S

M

IT

H

M S

M

IT

H

O C

R U

Z

/2

/2

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

1/8" = 1'-0"1

GROUNDING SYSTEMS MODIFICATION -

AREA D

KEY NOTES:

COPPER GROUND BAR (SEE DETAIL E, SHEET E-034)

EXISTING LOOP STYLE GROUND RECEPTACLE

EXISTING STUD STYLE GROUND RECEPTACLE

4 1"C., 1#4/0 BARE COPPER GROUND TO

MAIN ELECTRICAL GND BUS LOCATED IN

ROOM

5 1#4/0 BARE COPPER GROUND

1#4/0 BARE COPPER GROUND TO

BUILDING STEEL. SEE DETAIL G ON

DRAWING DETAIL I, E-032.

A m e n d m e n t

/8

/2

SCALE:

4' 8' 16'0

1/8" = 1'-0"

E002
Plot
E007
Plot
E-008
E-010
E-011
E-012
E-013
E-014
E-015
E-018
E-020
E-021
E-022

File details come from the government source that posted it. Updated .