Rev 2 Attach-2 N-T. ARCH & Interiors Adend 2.pdf

PDF 3 MB Posted

Attached to
Repair Maintenance (MTX) Hangar Building 1001 (B1001)
Solicitation number
W50S6Y24B0002
Issued by

About this file

This document is a solicitation for the F-35 Repair Maintenance Hangar Building 1001 (B1001) project at the 125th Fighter Wing (FW) Jacksonville International Airport (JIA) in Jacksonville, Florida. The Department of the Army Florida Army National Guard is seeking bids from small businesses for the repair and full renovation of the ground floor spaces, including demolition, new interior construction and finishes, HVAC, plumbing, electrical, lighting, grounding, fire protection, telecommunication, and access control/security systems. The estimated period of performance is 540 calendar days after notice to proceed. The project magnitude is between $10M and $20M. The North American Industry Classification (NAICS) code is 236220 and the size standard for small businesses is $45M. Award will be made to the responsible bidder whose bid conforms to the invitation and is most advantageous to the government, considering only price and price-related factors.

View the file

Other files

File Type Posted
Repair Hanger Abstract OF_1419-4.25.24-KO.pdf PDF
Bid Submission Day Sign-In Sheet-25APR24.pdf PDF
W50S6Y24B0002_00004 Repair MTX_19Apr24.pdf PDF
Rev 3 Attach-2 Adend 3- Electrical E-ED.pdf PDF
Set 06_Q-A_W50S6Y24B0002 Hanger.pdf PDF
QA Set 05 W50S6Y24B0002 Hanger.docx DOCX document
Rev 2 Attach-2 U. P-110B Adend 2.pdf PDF
Rev 2 Attach-2 E-M. STRC Adend 2.pdf PDF
Rev 2 Attach-2 C. CS402 ADEND2 signed.pdf PDF
Set 05_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Rev 2 Attach-2 A. CD100 Adend 2 signed.pdf PDF
Rev 2 Attach-2 B. CU100 Adend 2 signed.pdf PDF
Rev 2 Attach-1_22 00 00 Specs.pdf PDF
Rev 2 Attach-2 D. CS403 Adend 2 signed.pdf PDF
W50S6Y24B0002_00003 Repair MTX_3Apr24.pdf PDF
Rev 2 Attach-2 II. TY-101 ADEND #2.pdf PDF
Notifier Panel Pics.pdf PDF
Set 04_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Rev 2 Attach-2 V-HH. ELEC Adend 2.pdf PDF
Set 03_Q-A_W50S6Y24B0002 Hanger.pdf PDF
W50S6Y24B0002_00002 Repair MTX_28Mar24.pdf PDF
Site Visit Sign-In Sheet-20MAR24.pdf PDF
Hanger Pre-Proposal minutes.pdf PDF
MTX Pre-Bid slides B1001.pptx PPTX presentation
Set 02_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Addendum 01_Q-A_W50S6Y24B0002 Hanger.pdf PDF
Attach-7-125FW Form 2 Fillable (Aug 2023) - CAO 01MAR2024.pdf PDF
Rev 1 Attach-2-LSGA212001_B1001 Hangar Combined Drawings B-3_3.4.24.pdf PDF
Rev 1 Attach-1-LSGA212001_B1001 Hangar Combined Specifications B-3_3.4.24.pdf PDF
W50S6Y24B0002_00001 Repair MTX_5Mar24.pdf PDF
Attach-1-LSGA 212001_B1001 Hangar Combined Specifications B-3.pdf PDF
Attach-7-125FW Form 2 Installation Access Request dated Sep 2022.pdf PDF
Attach-4-JA-SS-LSGA212001-B-Advantor_Redacted.pdf PDF
Attach-2-LSGA 212001_B1001 Hangar Combined Drawings B-3.pdf PDF
Attach-3-JA-BN-LSGA212001-A-Best Locks_Cores-Redact.pdf PDF
W50S6Y24B0002 Repair MTX_29FEB24.pdf PDF
Attach-5-JA-BN-LSGA212001-C-Monaco-Redact.pdf PDF
Attach-6-JA-BN-LSGA212001-D-JCI Metasys-Redact.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A L

IG

N

24 2325 22 2126

B

C

D

E

F

G

H

J

K

L

24.1 21.1

STORAGE

106A

EJECTION SEAT

STORAGE

EGRESS OFFICE

OFFICE

MECH

CANOPY SHOP

MEN LOCKERS

W O

M E

N L

O C

K E

R S

FLIGHT LINE LO

OFFICE

115 MECH

COMM

117A COLLATERAL

STORAGE

118A

EQUIP./HAZMAT

STORAGE

ELEC

N. ENTRY

ELEC

OFFICE

123B

OFFICE

N. VESTIBULE

122 OFFICE

123A

A P

G S

U P

E R

V

IS

O R

S

NORTH HANGAR BAY

WHEEL & TIRE SHOP

W&T STORAGE

CORRIDOR

113A

VESTIBULE

116A

EJECTION SEAT

SHOP

107A

S

E E

S H

E E

T A

A

-1 B

A4A5

A3

A2

OFFICE

123C

1" / 12"

A7

A7

A11

116C

116A

107B

107D

106B

123C

123B

123A

118A

121A

107A

108A

108B

108D

107C

119G3A

G3A

G3C

1M8C

1M8A

M8A

G3A

G3AG3AG3A

24' - 5"

1M8A

1M8A1M8A

M8D

A-501

F3

A-501

C8

G3D

G3D

A-403

F3

8' - 3"

(+/-) 10' - 3"

A11 A11 A11

A1

A20

A9

A6

C L R

CLR

2' - 0"

A9

A9

1G6A

A19

A19

116D

A10 A10

A-501

F8

F3A-2

F3C-2F3C-2

A-501

C3

A23

6' - 0"

G3C

113B

G3C

G3C

G3C

117A

116B

A24

A25

M .O

M .O

M .O

M .O

A-501

C5

F3C-2

103B

F3C-2F3C-2

1M8A

113A

M .O

E2

A-301

A-501

F8 A-501

F6

F3A-2 F3A-2F3A-2

F3A-2

F3A-2

F3A-2

F3A-2

F3A-2 F3A-2

F3A-2

F3A-2

F3A-2

F3A-2

F3A-2

F3A-2F3A-2

F3A-2F3A-2

F3A-2

F3A-2

F3A-2

F3A-2

F3A-2

A-403 F1

1M8A

4' - 2" 9' - 11" 8' - 11"

ALIGN

18' - 6"

6' - 2"

M.O.

6' - 4" 11' - 0"

A-541

D2

11' - 1"

M.O.

3' - 4" 10' - 0"

ALIGN

A19

A23

M .O

F3A-2

A26A26

A26

A26

A27

A29

A28

F3A-2

1. SEE SHEET A-001 FOR GENERAL NOTES.

2. SEE SHEET A-002 FOR SYMBOLS AND MATERIALS.

3. SEE SHEET A-003 FOR TYPICAL MOUNTING HEIGHTS,

LOCATIONS AND DETAILS.

4. SEE SHEET A-004 FOR ADA DETAILS.

5. SEE SHEET A-005 FOR PARTITION TYPES.

6. SEE SHEET A-601 & A-602 FOR DOOR SCHEDULE AND

TYPES.

7. SEE SHEET I-601 FOR ROOM FINISH SCHEDULE.

8. DIMENSIONS OF EXTERIOR WALLS ARE TO INSIDE FACE OF

EXISTING CMU OR PRECAST U.N.O.

9. DIMENSIONS OF INTERIOR WALLS AND PARTITIONS ARE TO

FACE OF STUD, OR FACE OF CMU U.N.O.

10. DOOR OPENINGS SHALL BE LOCATED @ 8" FROM FACE OF

ADJACENT PARTITION IN CMU PARTITIONS OR 5" FROM

FACE OF PARTITION IN STUD AND PANEL PARTITIONS,

U.N.O.

11. CONTRACTOR SHALL LOCATE BLOCKING AND BACKING AS

REQUIRED FOR WALL MOUNTED EQUIPMENT,

CASEWORK/MILLWORK AND FURNISHINGS

EXISTING WALL ASSEMBLY TO REMAIN

NEW WALL ASSEMBLY

EXISTING DOOR TO REMAIN

NEW DOOR

EXISTING WINDOW TO REMAIN

NEW WINDOW

A B C

KEY PLAN

D

N

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

WALL LEGEND

SHEET NOTES

KEYNOTES#

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

G

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/3

/2

:3

:2

A

M

A-110A

P A

R T

IA

L F

IR

S

T F

L O

O R

P L A

N

A R

E A

A th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

M D

Z D

M D

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

SCALE: 1/8" = 1'-0"A1

PARTIAL FIRST FLOOR PLAN - AREA A

SCALE:

4' 8' 16'0

1/8" = 1'-0"

A1 PORTABLE CRANE (G.F.G.I.)

A2 PANEL RACKS (N.I.C)

A3 POWER CONVERTER (G.F.G.I.), SEE ELECTRICAL

DRAWINGS

A4 RADOME (SHOWN FOR REFERENCE)

A5 LEADING EDGE (SHOWN FOR REFERENCE)

A6 BENCH (N.I.C)

A7 CANOPY TRAILER (SHOWN FOR REFERENCE)

A9 EMERGENCY EYEWASH STATION, SEE PLUMBING

DRAWINGS

A10 F-35A AIRCRAFT (SHOWN FOR REFERENCE)

A11 EJECTION SEAT TRAILER (SHOWN FOR REFERENCE)

A19 NEW CMU INFILL AT EXISTING MASONRY OPENING (SEE

STRUCTURAL DRAWINGS), MAINTAIN 1 HOUR FIRE

RATING

A20 INFILL EXISTING OPENING AT DEMOLISHED OVERHEAD

DOOR. PROVIDE 3/4" STUCCO (TO MATCH EXISTING)

OVER 6" METAL STUDS WITH 5/8" GLASS MAT FACED

GYP. SHEATHING

A23 INFILL EXISTING METAL STUD OPENING

A24 NEW CONCRETE LANDING

A25 NEW SLOPED CONCRETE

A26 STRIPING AT EXISTING GROUNDING RECEPTACLE, PER

UFC AIRCRAFT MAINTENANCE BAY STRIPING

REQUIREMENTS

A27 STRIPING AT FIRE EXTINGUISHER, PER UFC AIRCRAFT

MAINTENANCE BAY STRIPING REQUIREMENTS

A28 STRIPING AT EMERGENCY EYEWASH/SHOWER, PER UFC

AIRCRAFT MAINTENANCE BAY STRIPING

REQUIREMENTS

A29 AIRCRAFT POSITION CENTERLINE, PER UFC AIRCRAFT

MAINTENANCE BAY STRIPING REQUIREMENTS

A

M E

N D

M E

N T

/0

/2

N A T I O N A L G U A R DF L O R I D A A I R

1. SEE SHEET A-001 FOR GENERAL NOTES

2. SEE SHEET A-601 & A-602 FOR DOOR SCHEDULE AND TYPES.

3. SEE CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND

ELECTRICAL DRAWINGS FOR MORE INFORMATION.

4. ELEVATIONS GIVEN ARE RELATIVE TO GROUND LEVEL T.O.

SLAB (0'-0"). SEE CIVIL FOR HEIGHT ABOVE SEA LEVEL.

5. SEE PLANS AND WALL SECTIONS FOR ROUGH OPENING

LOCATIONS, WINDOW & STOREFRONT TYPES.

6. PROVIDE AND COORDINATE KNOX BOX LOCATION WITH FIRE

DEPARTMENT PRIOR TO INSTALLATION.

7. VERTICAL DIMENSIONS ARE FROM FINISHED FLOOR (T.O.

SLAB), UNLESS NOTED OTHERWISE.

LEVEL 1

0' - 0"

LEVEL 2

17' - 0"

ROOF

48' - 0"

2423 252221201918 261716151413 13.113.2 14.114.2121110987654321 24.121.10 3.13.22.11.1

T.O. TAIL

MIN. CEILING CLEARANCE

MIN. DOOR CLEARANCE

A .F

.F

A38

(+/-) 2' - 9"

LEVEL 1

0' - 0"

LEVEL 2

17' - 0"

ROOF

48' - 0"

24 2325 22 21 20 19 1826 17 16 15 14 1313.113.214.1 14.2 12 11 10 9 8 7 6 5 4 3 2 124.1 21.1 03.1 3.2 2.1 1.1

A-541

D5116D

A .F

.F

2' - 0"

A .F

.F

(+/-) 5' - 8"

A .F

.F

3' - 3"

A42A42A35 A37 A39 A35A35 A37 A35 A35A35A43A .F

.F

A41

A .F

.F

A41A41 A41

LEVEL 1

0' - 0"

LEVEL 2

17' - 0"

ROOF

48' - 0"

A B C D E F G H J K L

10' - 0"

A .F

.F

3' - 6"

A35A35 A20 A36A34A34A33

A41 A41A41

LEVEL 1

0' - 0"

LEVEL 2

17' - 0"

ROOF

48' - 0"

ABCDEFGHJKL

A .F

.F

A35A35 A40A41

106 107A106A

KEY PLAN

A B C D

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

SHEET NOTES

KEYNOTES#

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/3

/2

:3

:2

A

M

A-201

E X

T E

R

IO

R E

L E

V A

T

IO

N S th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

M D

Z D

M D

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

SCALE: 3/64" = 1'-0"A1

EAST ELEVATION

SCALE: 3/64" = 1'-0"C1

WEST ELEVATION

SCALE:

0 16' 32' 48'

3/64" = 1'-0"

SCALE: 3/64" = 1'-0"E1

NORTH ELEVATION

SCALE: 3/64" = 1'-0"E2

SOUTH ELEVATION

WEST

N O

R T

H

S O

U T

H

EAST

A20 INFILL EXISTING OPENING AT DEMOLISHED OVERHEAD DOOR.

PROVIDE 3/4" STUCCO (TO MATCH EXISTING) OVER 6" METAL

STUDS WITH 5/8" GLASS MAT FACED GYP. SHEATHING

A33 NEW HM DOOR TO REPLACE EXISTING, SEE DOOR SCHEDULE

A34 NEW INSULATED OVERHEAD DOOR TO REPLACE EXISTING, SEE

DOOR SCHEDULE

A35 MECH. EQUIP., REFER TO MEP DRAWINGS

A36 NEW 12"X18" LOUVER, REFER TO MECH. DRAWINGS

A37 SAW CUT 12"X18" OPENING IN EXISTING PRECAST CONCRETE

PANEL FOR NEW LOUVER, REFER TO MECH. DRAWINGS

A38 SAW CUT 12"X24" OPENING IN EXISTING PRECAST CONCRETE

PANEL FOR NEW LOUVER, REFER TO MECH. DRAWINGS

A39 SAW CUT 24"X36" OPENING IN EXISTING PRECAST CONCRETE

PANEL FOR NEW LOUVER, REFER TO MECH. DRAWINGS

A40 SAW CUT 3'-4" X 7'-2" OPENING IN EXISTING PRECAST

CONCRETE PANEL FOR NEW DOOR ASSEMBLY, SEE DEMO

PLANS

A41 NEW EXTERIOR LIGHT FIXTURE, REFER TO ELEC. DRAWINGS

A42 ENLARGE EXISTING OPENING IN PRECAST CONCRETE PANEL

FOR NEW 3'-4" X 10'-2" DOOR ASSEMBLY, SEE STRUCTURAL

DRAWINGS

A43 INFILL EXISTING OPENING, PROVIDE 3/4" STUCCO (TO MATCH

EXISTING) OVER 6" METAL STUDS WITH 5/8" MAT FACED GYP.

SHEATHING, TYP. AT ALL ABANDONED LOUVER OPENINGS,

REFER TO HVAC DEMO DRAWINGS FOR QUANTITY OF

LOUVERS TO BE DEMOLISHED

A

M E

N D

M E

N T

/0

/2

D W

WD

16 15 14 13 12 11

J

K

L

A-402C4

MEN RESTROOMS

WOMEN

RESTROOMS

VESTIBULE

143B

LACTATION ROOM

CORRIDOR

143A

/2

S

L O

P E

U P

A-402E1 F1

A-402

E7

E5

F5

A-402 C1

A-402

C7

T-006

CLR.

ø 5' - 0"

C

LR

ø 5' - 0"

CLR.

4' - 0"

C L

R

CLR.

4' - 0"

C L

R

CLR.ø 5

0"

A6

A6

143A 143B

F3A-2 F3A-2

0' - 6"

147144

E3A-1

E3A-1E3A-1

E3A

E3A-1 E3A-1

E3A

E3A

E3A

E3A

E3A

E3A

E3A

TYP. OF 9

A12

A12

A12

T-004

T-003

T-005

TYP. OF 3

TYP. OF 3

E3A

A12

CLR.

4' - 8"

C L

R

C L

R

CLR.

4' - 8"

TYP. OF 5

T-003

T-004

F3A-2

E3A-1E3A-1

E3A-1

G3A

E3A-1E3A-1

F3A-2

F3A-2F3A-2 F3A-2F3A-2F3A-2

F3B F3B

2' - 1"

E3A-1

F5

A-401

TYP.

F1

A-401

TYP.

F5

A-401

TYP.

F1

A-401

TYP.

/2

0' - 0"

A19

F3A-2F3B

E3A-1

T-004 T-007

T-007 T-004

TPT-1

TPT-1

A32

A32

V.I.F.

33' - 4"

F3

A-401

TYP.

F3

A-401

TYP.

E3A

E3A-1

A-403

D9

5' - 10"

JANITOR

147BG3B

G3B

G3B

147B

F3B

E3A

E3A

F6A-2

8"

V.I.F.

17' - 0"

F3B

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 1 1/2"

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 0"

CLR.

3' - 1 1/2"

2 1/2" STUD WALL

T-007

T-006T-006

2 1

F

G

3.1 1.1

MEN RESTROOM

WOMEN RESTROOM

BATTERY (CHARGE)

BATTERY

(STORAGE)

A-402A1

A-402 A6

T-005

G3B

A9

A9

G3A-2G3A-2

F3A-2

A15

A15

A15

5' - 8" 5' - 0"

A19

A16

A16

A14

A-402 A5

184 183

E3A-1

E3A-1

E3A-2

E A

-2 E

A

-2

TYP. OF 3

TYP. OF 3

TYP. OF 2

TYP. OF 2

T-003

T-004

T-006T-006

T-003

T-005

G3B

F3A-2 F3A-2

E0A E3A-1

E3A-1

F2A

E0A

E0AE0AE0A E0A

C L

R

C L

R

T-004

T-007

T-007

T-008

T-009

T-008

T-009

T-004

T-004

TPT-2

TPT-2

F5

A-401

TYP.

F5

A-401

TYP.

F1

A-401

TYP.

C L

R

C L

R

2' - 0"

/2

1. SEE A-002 & A-003 FOR ADDITIONAL INFORMATION ON FIXTURE

MOUNTING HEIGHTS. ALL REQUIRED ADA CLEARANCES ARE TO

FACE OF FINISH.

2. SEE A-005 FOR PARTITION TYPES AND DETAILS

3. SEE A-561 FOR MILLWORK DETAILS.

4. SEE INTERIOR DRAWINGS FOR FINISH PLANS AND SCHEDULE.

5. INSULATE ALL UNDER COUNTER HOT WATER AND WASTE LINES.

6. COORDINATION OF BLOCKING REQUIREMENTS FOR WALL-

MOUNTED SPECIALTIES BY CONTRACTOR.

7. CONFIRM REQUIREMENTS AND SIZES FOR ALL

EQUIPMENT/APPLIANCES PRIOR TO CONSTRUCTION OF

CABINETRY/COUNTERS.

8. CONTRACTOR TO COORDINATE ROUGH OPENINGS WITH

EQUIPMENT AND CASEWORK TO BE INSTALLED IN WALL AREAS.

PROVIDE A COMPLETE INSTALLATION AND SCRIBE CLOSURES

OF THE OPENING FOR A FINISHED LOOK.

9. PROVIDE CONTINUOUS SHIM AT ALL MIRRORS TRANSITIONING

OVER WAINSCOT TO WALL.

EXISTING WALL ASSEMBLY TO REMAIN

NEW WALL ASSEMBLY

EXISTING DOOR TO REMAIN

NEW DOOR

EXISTING WINDOW TO REMAIN

NEW WINDOW

LEVEL 1

0' - 0"

8' - 0"

CEILING HEIGHT

SOLID SURFACE SINGLE

THRESHOLD SHOWER RECEPTOR

SOLID SURFACE SHOWER WALL

PANEL

1/2" CEMENT BOARD

3 5/8" METAL STUD U.N.O. ON PLAN

CEILING PER RCP'S

PLUMBING IN CAVITY, SEE

PLUMBING DRAWINGS

LEVEL 1

0' - 0"

LEVEL 2

17' - 0"

SOLID SURFACE SINGLE

THRESHOLD SHOWER RECEPTOR

3 5/8" METAL STUD U.N.O. ON PLAN

R-11 BATT INSULATION

1/2" CEMENT BOARD

SOLID SURFACE SHOWER WALL

PANEL

CEILING PER RCP'S

5/8" GWB

EXISTING STRUCTURE ABOVE

8' - 0"

CEILING HEIGHT

LEVEL 1

0' - 0"

8' - 0"

8' - 6"

CEILING HEIGHT

CEILING HEIGHT

SOLID SURFACE SINGLE

THRESHOLD SHOWER RECEPTOR

SOLID SURFACE SHOWER WALL

PANEL

1/2" CEMENT BOARD

CEILING PER RCP'S

5/8" GWB

CEILING PER RCP'S

WALL BASE AND FLOOR

FINISH PER FINISH SCHEDULE

3 5/8" METAL STUD U.N.O. ON PLAN

M A

X

/2

"FLOOR TILE AS

SCHEDULED

SHOWER DRAIN, COORDINATE

WITH PLUMBING DRAWINGS

SOLID SURFACE ADA

SHOWER RECEPTOR

A-401

F5

TYP.

SLOPE

SIM.

KEY PLAN

N

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

WALL LEGEND

TOILET ROOM ACCESORY SCHEDULE

SHEET NOTES

KEYNOTES#

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/3

/2

:3

:3

A

M

A-401

E N

L A

R G

E D

F L O

O R

P L A

N S th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

M D

Z D

M D

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

SCALE:

2' 4' 8'0

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"A1

ENLARGED PLAN

SCALE: 1/4" = 1'-0"A7

ENLARGED PLAN

T-001 36 INCH STRAIGHT PEENED GRAB BAR

T-002 42 INCH STRAIGHT PEENED GRAB BAR

T-003 LAVATORY-MOUNTED SOAP DISPENSER

T-004 DOUBLE-ROLL TOILET TISSUE DISPENSER

T-005 GLASS MIRROR WITH STAINLESS STEEL ANGLE FRAME

T-006 SURFACE MOUNTED COMBINATION TOWEL AND WASTE

UNIT

T-007 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

T-008 SURFACE MOUNTED ROBE HOOK

T-009 SHOWER CURTAIN, ROD AND HOOKS

B1

B7

A6 BENCH (N.I.C)

A9 EMERGENCY EYEWASH STATION, SEE PLUMBING DRAWINGS

A12 LOCKERS (N.I.C)

A14 BATTERY STORAGE SHELVING (N.I.C.)

A15 WORK TABLE (N.I.C.)

A16 WATER HEATER, SEE PLUMBING DRAWINGS

A19 NEW CMU INFILL AT EXISTING MASONRY OPENING (SEE

STRUCTURAL DRAWINGS), MAINTAIN 1 HOUR FIRE RATING

A32 EXISTING WASHER & DRYER TO REMAIN

SCALE:

1 1/2" = 1'-0"

6" 1'-0" 1'-6"

SCALE: 1 1/2" = 1'-0"F1

WALL DETAIL

SCALE: 1 1/2" = 1'-0"F5

WALL DETAIL

SCALE: 1 1/2" = 1'-0"F3

WALL DETAIL

SCALE: 1 1/2" = 1'-0"E7

ADA THRESHOLD DETAIL

A

M E

N D

M E

N T

/0

/2

TYPE CTYPE A TYPE B

TYPE D

8" 8"

V A

R

IE

S

TYPE E

FLUSH HOLLOW METAL MEDIUM STILE

ALUM. ENTRANCE

WIDE STILE ALUM. ENTRANCE

DOOR & CURTAIN WALL

FRAMING SYSTEM TO MATCH

EXIST. STAIR ENTRIES

FLUSH HOLLOW METAL

W/ 10X10 LITE

FLUSH HOLLOW METAL

W/ NARROW LITE

3 1/2" 3 1/2"

/2

SEE SCHEDULE

TYPE F

OVERHEAD COILING

4' - 10"

5" 5"

GL-1

GLAZING LEGEND

GL-1 INSULATED GLAZING UNIT

GL-2 TEMPERED SAFETY GLAZING

(FIRE RATED SAFETY GLAZING WHERE

DOORS ARE INDICATED AS FIRE RATED)

GL-1

GL-1

GL-1

GL-1

GL-1

GL-2

GL-2

TYPE 1

TYPE 2

2" 2"

2" 2"

2" 2"

TYPE 4

TYPE 3

2" 2"

TYPE 5

2" 2"

HOLLOW METAL

TRANSOM PANEL

NOTE 1:

HANGER EGRESS DOOR TO MEET UFC 4-211-01

AIRCRAFT MAINTENANCE HANGARS REQUIREMENT OF

DOORS AT 150' MAX. AROUND PERIMETER OF HANGAR

BAYS, AND ALSO WITHIN 20' OF EACH END OF HANGAR

BAY DOOR OPENING. PROVIDE HANGAR EGRESS DOOR

WITH/ PANIC DEVICE, SWING DOOR IN DIRECTION OF

TRAVEL, AND PROVIDE FOR CARD READER ACCESS TO

HANGAR BAY ( AS PART OF ADVANTOR ACCESS

CONTROL, REFER TO TELECOM DRAWINGS.)

NOTE 2:

PROVIDE MECHANICAL PUSH BUTTON COMBINATION

LOCK FROM HANGAR BAY SIDE.

NOTE 3:

EXISTING DOOR AND FRAME ASSEMBLY TO REMAIN.

REMOVE FRAME SILENCERS, REPAINT DOOR & FRAME

ASSEMBLY COMPLETE, PROVIDE NEW FRAME

SILENCERS.

1. REPLACE HARDWARE AS INDICATED BY HARDWARE GROUP

NUMBER SHOWN.

2. WHERE STC RATING IS INDICATED FOR NEW DOOR

ASSEMBLY, PROVIDE INSULATED H.M DOOR W/ HEAD & JAMB

SEALS.

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

DOOR SCHEDULE REMARKS

DOOR SCHEDULE GENERAL NOTES

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/3

/2

:3

:2

A

M

A-601

D O

O R

S C

H E

D U

L E th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

M D

Z D

M D

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

DOOR SCHEDULE

MARK

DOOR FRAME

HEAD JAMB SILL

FIRE

RATING

STC

RATING

HDWR.

GROUP EXISTING / NEW

EXISTING

HDWR. ELEC. HDW. REMARKSWIDTH HEIGHT THK. TYPE MATL. TYPE MATL.

000 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - - Existing NOT IN SCOPE

101 PR. 3' - 0" 8' - 0" 1 3/4" C ALUM/GLASS 3 ALUM. - - 3.0 Existing REPLACE EXISTNG PANIC HARDWARE, NOTE 1

102 PR. 3' - 0" 8' - 0" 1 3/4" C ALUM/GLASS 3 ALUM. - - 3.0 Existing REPLACE EXISTING PANIC HARDWARE, NOTE 1

103 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 4 H.M. E9/A-611 C9/A-611 A6/A-611 - - 15.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

103B 3' - 0" 7' - 0" 1 3/4" A H.M. 2 H.M. E9/A-611 C9/A-611 A6/A-611 - - 20.0 New Construction -

104 3' - 4" 7' - 0" 1 3/4" A H.M. 2 H.M. E9/A-611 C9/A-611 A6/A-611 - - 16.0 New Construction -

106 10' - 6" 12' - 0" 3" F E1/A-611 C1/A-611 - - 24.0 New Construction - MOTOR OPERATED

106A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E3/A-611 C3/A-611 A9/A-611 - - New Construction -

106B 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - Existing MORTISE NOTE 3

107 3' - 0" 7' - 0" 1 3/4" D H.M. 2 H.M. - - 4.0 Existing ACCESS CONTROL; REF. TELCOM, NOTE 3

107A 10' - 0" 7' - 6" 3" F E1/A-611 C1/A-611 - - 24.0 New Construction - YES MOTOR OPERATED

107B PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - - Existing MORTISE NOTE 3

107C 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 39 16.0 New Construction -

107D PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - - Existing MORTISE NOTE 3

108 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 4 H.M. E9/A-611 C9/A-611 A6/A-611 45 MIN. - 15.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

108A PR. 3' - 4" 7' - 0" 1 3/4" A H.M. 4 H.M. E9/A-611 C9/A-611 A6/A-611 45 MIN. - 15.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

108B PR. 3' - 4" 7' - 0" 1 3/4" A H.M. 4 H.M. E9/A-611 C9/A-611 A6/A-611 45 MIN. - 15.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

108D 3' - 4" 6' - 8" 1 3/4" A H.M. 2 H.M. E3/A-611 C3/A-611 A6/A-611 - - 20.0 New Construction -

109 3' - 0" 7' - 4" 1 3/4" C ALUM/GLASS 1 ALUM. - - 25.0 Existing MORTISE

110 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - - Existing MORTISE NOTE 3

111 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - - 23.0 New Construction -

112 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - - 23.0 New Construction -

113A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E9/A-611 C9/A-611 A6/A-611 - - 10.0 New Construction - NOTE 1

113B 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - 1.0 Existing YES ACCESS CONTROL; REF. TELCOM, NOTE 3

114 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 39 16.0 New Construction -

115 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - 25.0 Existing MORTISE NOTE 3

116A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 4 H.M. 45 MIN. - Existing MORTISE NOTE 2, NOTE 3

116B PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. E5/A-611 C5/A-611 A6/A-611 - - 18.0 New Construction -

116C 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - 4.0 Existing MORTISE YES ACCESS CONTROL; REF. TELCOM, NOTE 3

116D 3' - 0" 7' - 0" 1 3/4" A H.M. 5 H.M. E3/A-611 C3/A-611 A9/A-611 - 4.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

117A 3' - 0" 7' - 0" 1 3/4" A H.M. 2 H.M. E9/A-611 C9/A-611 A6/A-611 - - 16.0 New Construction -

118 3' - 0" 6' - 8" 1 3/4" A H.M. 1 H.M. - - Existing CYLINDRICAL NOTE 3

118A PR. 3' - 8" 6' - 6" 3 1/4" - STEEL - STEEL E7/A-611 C7/A-611 A4/A-611 45 MIN. - New Construction - NEW VAULT DOOR PAIR, GSA CLASS 5V, 80"W X 78"

H. CLEAR OPG. NOTE 2

119 2' - 8" 7' - 2" 1 3/4" A H.M. 1 H.M. - - Existing CYLINDRICAL NOTE 3

120 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - - 16.0 New Construction -

121 3' - 0" 7' - 0" 1 3/4" B H.M. 1 H.M. 60 MIN. - 11.0 Existing MORTISE PUSH PLATE (OLD MORTISE PREP) REPLACE

HARDWARE WITH NEW PANIC DEVICE, NOTE 1,

NOTE 3

121A 3' - 0" 7' - 0" 1 3/4" C ALUM/GLASS 1 ALUM. - - 7.0 Existing MORTISE YES ACCESS CONTROL; REF. TELCOM

122 3' - 6" 8' - 0" 1 3/4" E ALUM/GLASS ALUM. - - Existing MORTISE YES PANIC EXIST. MAG LOCK W/ KEYPAD

123 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - 39 17.0 New Construction -

123A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - 39 17.0 New Construction -

123B 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - 39 17.0 New Construction -

123C 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - 39 17.0 New Construction -

124 3' - 0" 6' - 8" 1 3/4" A H.M. 1 H.M. - - Existing CYLINDRICAL NOTE 3

125 3' - 0" 7' - 0" 1 3/4" A H.M. 2 H.M. - - 20.0 Existing MORTISE DEMO. EXIST. DETEX ALARM DEVICE. REPLACE

WITH NEW LOCKSET, NOTE 3

125A PR. 3' - 0" 7' - 2" 1 3/4" A H.M. 3 H.M. 45 MIN. - Existing MORTISE NOTE 2, NOTE 3

125B 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - - 20.0 New Construction -

126 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - - Existing MORTISE NOTE 3

126A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A4/A-611 - 39 17.0 New Construction -

127 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - - 6.0 Existing MORTISE YES ACCESS CONTROL; REF. TELCOM, NOTE 3

127A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. 45 MIN. - Existing NOTE 2, NOTE 3

127B PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. E5/A-611 C5/A-611 A6/A-611 - - 14.0 New Construction -

127C PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. E5/A-611 C5/A-611 A6/A-611 - - 12.0 New Construction -

127D 10' - 6" 11' - 8" 3" - Existing OVERHEAD DOOR TO REMAIN

128 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - - 23.0 New Construction -

129 3' - 4" 7' - 2" 1 3/4" A H.M. 1 H.M. - - Existing CYLINDRICAL NOTE 3

130 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - 25.0 Existing MORTISE NOTE 3

131A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - Existing NOTE 3

131B 3' - 0" 7' - 0" 1 3/4" B H.M. 2 H.M. E9/A-611 C9/A-611 A6/A-611 45 MIN. - 11.0 New Construction MORTISE NOTE 1

131C 3' - 0" 7' - 0" 1 3/4" B H.M. 2 H.M. 45 MIN. - 11.0 Existing MORTISE NOTE 1

131D 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. 45 MIN. - Existing PANIC DEVICE-RIM, NOTE 1, NOTE 3

131E 3' - 0" 7' - 0" 1 3/4" C ALUM/GLASS 1 ALUM. - - 1.0 Existing MORTISE YES PANIC DEVICE-RIM, ACCESS CONTROL; REF.

TELCOM

131F 3' - 0" 7' - 0" 1 3/4" C ALUM/GLASS 1 ALUM. - - 1.0 Existing MORTISE PANIC DEVICE, ACCESS CONTROL; REF. TELCOM

132 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - - 25.0 Existing MORTISE NOTE 3

134 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. 45 MIN. - Existing MORTISE NOTE 3

135 3' - 0" 7' - 0" 1 3/4" B H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 39 11.0 New Construction -

135A 3' - 0" 7' - 0" 1 3/4" B H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 39 11.0 New Construction -

136 3' - 0" 7' - 0" 1 3/4" B H.M. 2 H.M. - - Existing MORTISE NOTE 3

138 3' - 0" 7' - 0" 1 3/4" D H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - - 20.0 New Construction -

138A 3' - 0" 7' - 0" 1 3/4" D H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - - 20.0 New Construction -

138B 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - - 19.0 New Construction -

138C 10' - 0" 7' - 0" C ALUM/GLASS ALUM. - - - - 24.0 New Construction - 4 LEAVES, SLIDING, CENTER BI-PARTING

DOOR TYPES

FRAME TYPES

A

M E

N D

M E

N T

/0

/2

NOTE 1:

HANGER EGRESS DOOR TO MEET UFC 4-211-01

AIRCRAFT MAINTENANCE HANGARS REQUIREMENT OF

DOORS AT 150' MAX. AROUND PERIMETER OF HANGAR

BAYS, AND ALSO WITHIN 20' OF EACH END OF HANGAR

BAY DOOR OPENING. PROVIDE HANGAR EGRESS DOOR

WITH/ PANIC DEVICE, SWING DOOR IN DIRECTION OF

TRAVEL, AND PROVIDE FOR CARD READER ACCESS TO

HANGAR BAY ( AS PART OF ADVANTOR ACCESS

CONTROL, REFER TO TELECOM DRAWINGS.)

NOTE 2:

PROVIDE MECHANICAL PUSH BUTTON COMBINATION

LOCK FROM HANGAR BAY SIDE.

NOTE 3:

EXISTING DOOR AND FRAME ASSEMBLY TO REMAIN.

REMOVE FRAME SILENCERS, REPAINT DOOR & FRAME

ASSEMBLY COMPLETE, PROVIDE NEW FRAME

SILENCERS.

1. REPLACE HARDWARE AS INDICATED BY HARDWARE GROUP

NUMBER SHOWN.

2. WHERE STC RATING IS INDICATED FOR NEW DOOR

ASSEMBLY, PROVIDE INSULATED H.M DOOR W/ HEAD & JAMB

SEALS.

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

DOOR SCHEDULE REMARKS

DOOR SCHEDULE GENERAL NOTES

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/3

/2

:2

:3

P

M

A-602

D O

O R

S C

H E

D U

L E th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

M D

Z D

M D

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

DOOR SCHEDULE (CONT.)

MARK

DOOR FRAME

HEAD JAMB SILL

FIRE

RATING

STC

RATING

HDWR.

GROUP EXISTING/NEW

EXISTING

HDWR.

ELEC.

HDW. REMARKSWIDTH HEIGHT THK. TYPE MATL. TYPE MATL.

139 3' - 0" 7' - 0" 1 3/4" D H.M. 2 H.M. 60 MIN. Existing MORTISE EXISTING PANIC DEVICE, NOTE 3

139A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 60 MIN. 16.0 New Construction -

140 3' - 0" 7' - 0" 1 3/4" A H.M. 2 H.M. - 25.0 Existing MORTISE NOTE 3

141 3' - 0" 7' - 0" 1 3/4" A H.M. 2 H.M. - 25.0 Existing MORTISE NOTE 3

142 3' - 0" 7' - 0" 1 3/4" A H.M. 2 H.M. - 25.0 Existing NOTE 3

143 3' - 0" 8' - 0" 2" E ALUM/GLASS - ALUM. - 1.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

143A 3' - 0" 7' - 0" 1 3/4" D H.M. 1 H.M. E7/A-611 C7/A-611 A6/A-611 45 MIN. 22.0 New Construction - NOTE 1, NOTE 3

143B 3' - 0" 7' - 0" 1 3/4" D H.M. 2 H.M. E7/A-611 C7/A-611 A6/A-611 45 MIN. 22.0 New Construction -

143C 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 11.0 New Construction -

144 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing - EXISTING PUSH/PULL, NOTE 3

145 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 16.0 Existing MORTISE NOTE 3

147 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing - EXISTING PUSH/PULL, NOTE 3

147B 2' - 8" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 16 New Construction

148 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. 45 MIN. Existing MORTISE NOTE 3

148A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - Existing MORTISE NOTE 3

149 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - Existing MORTISE NOTE 3

152 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 20.0 New Construction -

152A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. 45 MIN. Existing MORTISE NOTE 2, NOTE 3

153 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing NOT IN SCOPE

154 3' - 0" 7' - 0" 1 3/4" A WOOD. 1 H.M. - Existing MORTISE EXISTING NOT IN SCOPE

154A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing NOT IN SCOPE

155 PR. 3' - 4" 7' - 0" 1 3/4" A H.M. 3 H.M. - Existing MORTISE NOT IN SCOPE

156 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 25.0 Existing CYLINDRICAL NOTE 3

157 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 25.0 Existing CYLINDRICAL NOTE 3

158 3' - 0" 7' - 0" 1 3/4" A H.M. 5 H.M. E3/A-611 C3/A-611 A9/A-611 2.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

159 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. E3/A-611 C3/A-611 A6/A-611 - 12.0 New Construction -

159A PR. 4' - 0" 7' - 2" 1 3/4" A H.M. 3 H.M. 45 MIN. Existing CYLINDRICAL NOTE 2, NOTE 3

160 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 25.0 Existing CYLINDRICAL NOTE 3

161 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing CYLINDRICAL NOTE 3

162 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E3/A-611 C3/A-611 A6/A-611 - 23.0 New Construction -

163 2' - 8" 7' - 2" 1 3/4" A H.M. 1 H.M. - Existing CYLINDRICAL

164 3' - 0" 7' - 0" 1 3/4" B H.M. 1 H.M. 60 MIN. 22.0 Existing MORTISE PUSH/PULL (OLD MORTISE PREP), NOTE 1, NOTE 3

164A 3' - 0" 7' - 0" 1 3/4" C ALUM/GLASS 1 ALUM. - 8.0 Existing MORTISE YES ACCESS CONTROL; REF. TELCOM

165 3' - 6" 8' - 0" 1 3/4" E ALUM/GLASS ALUM. - Existing MORTISE YES ACCESS CONTROL; REF. TELCOM

167 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 8.0 Existing MORTISE KEY PAD PANIC DEVICE, NOTE 3

167A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing MORTISE NOTE 3

168 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 16.0 New Construction -

169 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. E5/A-611 C5/A-611 A6/A-611 - 14.0 New Construction -

169A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 4 H.M. 45 MIN. Existing MORTISE NOTE 2, NOTE 3

169B PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. E5/A-611 C5/A-611 A6/A-611 - 14.0 New Construction -

170 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 21.0 New Construction -

171 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing CYLINDRICAL NOTE 3

172 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 25.0 Existing CYLINDRICAL NOTE 3

176 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - 6.0 Existing MORTISE ACCESS CONTROL; REF. TELCOM, NOTE 3

176A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. 45 MIN. Existing MORTISE NOTE 2, NOTE 3

176B PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - Existing MORTISE EXISTING X-10 COMBO LOCK, NOTE 3

176C 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing CYLINDRICAL NOTE 2, NOTE 3

177 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 25.0 Existing MORTISE NOTE 3

179 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 25.0 Existing MORTISE NOTE 3

180 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E3/A-611 C3/A-611 A9/A-611 - 4.0 New Construction - YES ACCESS CONTROL; REF. TELCOM

180A PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - Existing MORTISE NOTE 3

181 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - 1.0 Existing MORTISE YES PANIC DEVICE, ACCESS CONTROL; REF. TELCOM, NOTE 3

181A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. 45 MIN. 11.0 Existing MORTISE NOTE 1, NOTE 3

182 PR. 3' - 0" 7' - 0" 1 3/4" A H.M. 3 H.M. - Existing MORTISE NOTE 3

183 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing MORTISE NOTE 3

184 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. - Existing MORTISE NOTE 3

185 3' - 0" 7' - 0" 1 3/4" D H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 45 MIN. 10.0 New Construction - PANIC DEVICE

185A 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E5/A-611 C5/A-611 A6/A-611 - 9.0 New Construction - PANIC DEVICE

186 3' - 0" 7' - 0" 1 3/4" A H.M. 1 H.M. E9/A-611 C9/A-611 A6/A-611 45 MIN. 10.0 New Construction - PANIC DEVICE

187 PR. 2' - 6" 7' - 0" 1 3/4" A H.M. 4 H.M. - 5.0 Existing CYLINDRICAL NOTE 3

A

M E

N D

M E

N T

/0

/2

UP

D W

WD

UP

CPT-1

EPFP

EPTP

LVT-1

N.I.C.

PFT-1

SC

OFFICE

CORRIDOR

OFFICE

ELEVATOR

ELECTRICAL

PILOT DEBRIEF

136BREAK ROOM

VESTIBULE

131B

CORRIDOR

131A

VESTIBULE

131C

STAIRS

ELEC

139A

MULTIPURPOSE

ROOM

CORRIDOR

131D

OFFICE

LOCKHEED

LOCKHEED

CORRIDOR

MEN RESTROOMS

WOMEN

RESTROOMS

VESTIBULE

143B

LACTATION ROOM

ELECTRICAL

MECHANICAL

NORTH HANGAR BAY

TRAINING

OFFICE

RADIO DISPATCH

126A

VESTIBULE

125A

VESTIBULE

127A

WOMEN LOCKERS

MECH

127B

CORRIDOR

143A

MENS LOCKERS

READY ROOM

CG

CG

CG

CG

CG

CG

CG

CG

CG CG

CG

CG CG

CG

CG

CG CG

CG CG

5' - 0"

WM-1

8' - 0"

WM-1

PT-2

PT-2

PT-2

PT-2

PT-2

PT-2

P T

-3

PT-2

S

E E

S H

E E

T A

I-

S

E E

S H

E E

T A

I-

SS AB SS AB SS AB SS AB

SOLID SURFACE

SHOWER PAN, SEE

PLUMBING

JANITOR

147B

FINISH LEGEND

CORNER

GUARD

STAINLESS STEEL

CORNER GUARD

ACCENT PAINT

LOCATION

WM-1 LOOSE-LAY

WALK-OFF MAT

PT-X

CG

SCG

SB-1 SWITCH

BOARD MAT

AB ALUMINUM

BLINDS

AB

A B C

KEY PLAN

D

N

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/2

/2

:5

:5

P M

I-102

F

IR

S T

F L O

O R

A

R E

A

B

IN

T E

R

IO

R F

IN

IS

H P

L A

N th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

K D

S

K D

S

A D

S

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR - AREA "B" - INTERIOR FINISH PLAN

SCALE:

4' 8' 16'0

1/8" = 1'-0"

A

M E

N D

M E

N T

/0

/2

CEILING

ACT-1 ACOUSTICAL CEILING TILE: ARMSTRONG, ULTIMA HEALTH ZONE,

SQUARE LAY-IN, 24"X24", WHITE, PRELUDE GRID

CP-1 CEILING PAINT: SHERWIN WILLIAMS, CEILING BRIGHT WHITE, SW7007

EXP EXPOSED DRYFALL: PAINTED TO MATCH SHERWIN WILLIAMS, CEILING

BRIGHT WHITE, SW7007

WALLS

PT-1 PAINT: SHERWIN WILLIAMS, ONLINE SW7072, EGGSHELL

PT-2 ACCENT PAINT: SHERWIN WILLIAMS, WEB GRAY SW7075, EGGSHELL

PT-3 ACCENT PAINT: SHERWIN WILLIAMS, RAINSTORM SW6230, EGGSHELL

PT-4 EPOXY PAINT: SHERWIN WILLIAMS, ONLINE SW7072, EGGSHELL, TWO-

PART WATERBASE CATALYZED EPOXY

PT-5 EPOXY PAINT: SHERWIN WILLIAMS, HIGH REFLECTIVE WHITE SW7757,

EGGSHELL,TWO- PART WATERBASE CATALYZED EPOXY

TP-1 TRIM PAINT: SHERWIN WILLIAMS, WEB GRAY SW7075, SEMIGLOSS

PWT-1 PORCELAIN WALL TILE: CROSSVILLE, OWEN STONE, MITTENS OST04,

12"X24"

PWT-2 PORCELAIN WALL TILE: CROSSVILLE, RETRO ACTIVE 2.0, ROYAL NAVY,

6"X24"

SCG CORNER GUARD: INPRO, SURFACE MOUNT STAINLESS STEEL CORNER

GUARD, 3.5" WING, 8' HIGH

CG CORNER GUARD: INPRO, 150 HIGH IMPACT CORNER GUARD, 3" WING,

8' HIGH,

WALL BASE

RB-1 RUBBER WALL BASE: TARKETT, 4" COVE, BEDROCK CG TA6

EPFP FIVE STEP RESINOUS EPOXY SYSTEM: SHERWIN WILLIAMS,

RESUFLOR SCREED TG46 FUEL RESISTANT, COLOR: WHITE, INTEGRAL 6"

COVE BASE.

EPTP THREE STEP RESINOUS EPOXY SYSTEM: SHERWIN WILLIAMS, 3-COAT

SYSTEM, RESUFLOR PERFORMANCE HTS, COLOR: STEEL GRAY #54,

INTEGRAL 6" COVE BASE.

PTB-1 PORCELAIN TILE BASE: CROSSVILLE, NOTORIOUS, FILM NOIR, 4"X12"

BULLNOSE

FLOOR

CPT-1 CARPET TILE: J+J FLOORING, KINETEX, URBAN AVENUE, ZONE 1560

LVT-1 LUXURY VINYL TILE: TARKETT, CONTOUR SERIES, MODERN WOOD, LOFT

OAK 3732, 48"X6" PLANK, INSTALL STAGGERED RANDOM

PFT-1 PORCELAIN FLOOR TILE: CROSSVILLE, NOTORIOUS, FILM NOIR,12"X24"

EPFP FIVE STEP RESINOUS EPOXY SYSTEM: SHERWIN WILLIAMS,

RESUFLOR SCREED TG46 FUEL RESISTANT, COLOR: WHITE, INTEGRAL 6"

COVE BASE. MANUFACTURER SHALL MATCH EXISTING FLOORING

STRIPING.

EPTP THREE STEP RESINOUS EPOXY SYSTEM: SHERWIN WILLIAMS, 3-COAT

SYSTEM, RESUFLOR PERFORMANCE HTS, COLOR: STEEL GRAY #54,

INTEGRAL 6" COVE BASE. MANUFACTURER SHALL MATCH EXISTING

FLOORING STRIPING.

WLK-1 WALK-OFF TILE: MILLIKEN, OBEX TILE, CUTX/DRIFT, BLUE DTX27-126,

20"X20"

SC SEALED CONCRETE: SEE SPEC

SDT-1 STATIC DISSIPATIVE TILE: FORBO, COLOREX VINYL TILE, SD 150213

SAHARA, 24"X24"

RTF-1 RUBBER TILE FLOOR: SPORTFLOOR, STAMINA, BLACK, INTERLOCK,

22.2"X22.2"

WM-1 WALK-OFF MAT, LOOSE LAY: C-S GROUP, DESIGNSTEP ENTRANCE

CARPET, CARPET MATS, POWER POINT PWPT, WROUGHT IRON 905, SEE

SHEETS I-101, I-102 AND I-104 FOR MAT SIZES.

SB-1 SWITCHBOARD MAT: ARMERICAN FLOOR MATS, CORUGATED

SWITCHBOARD MATS, CLASS 4 , 1/2"X3'X10', BLACK. SEE SHEET I-104.

MISC.

SS SOLID SURFACE: WILSONART, CLOUD MIST

PL-1 PLASTIC LAMINATE: WILSONART, VERANDA TEAK

GR-1 GROUT: LATICRETE, PERMACOLOR SELECT, DUSTY GREY 06

GR-2 GROUT: LATICRETE, PERMACOLOR SELECT,

AB ALUMINUM BLINDS: SWF CONTRACT, CLASSIC 1" MINI BLINDS, GREIGE

TPT-1 TOILET PARTITIONS: PSISC, PHENOLIC PARTITIONS, NAVY BLUE 969,

FLOOR TO CEILING MOUNTED

TPT-2 TOILET PARTITIONS: PSISC, PHENOLIC PARTITIONS, NAVY BLUE 969,

OVERHEAD BRACED

FINISH LEGEND

R1. PWT-1 TO ABUT PFT-1 USING SCHLUTER FLOOR TO WALL TRIM.

R2. NEW PT-4 UP TO THE HEIGHT OF THE EXISTING BIRD NETTING.

R3. PFT-2 TO BE INSTALLED IN ALL SHOWER FLOORS.`

REMARKS

1. CONTRACTOR SHALL READ ALL NOTES BEFORE BEGINNING

WORK.

2. FURNISH AND INSTALL MATERIALS IN COMPLIANCE WITH

MANUFACTURER'S PRINTED SPECIFICATIONS AND INSTALLATION

INSTRUCTIONS.

3. ANY DISCONTINUED ITEMS SHALL BE BROUGHT TO THE

ATTENTION OF THE GOVERNMENT IMMEDIATELY. CONTRACTOR

TO NOTIFY GOVERNMENT OF ANY ITEMS REQUIRING FURTHER

CLARIFICATION OF FINISH SELECTION.

4. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO

ORDERING OF MATERIALS. DO NOT SCALE ARCHITECTURAL

DRAWINGS. REFER TO DIMENSIONED PLANS

5. CONTRACTOR SHALL PROVIDE TO OWNER ALL

MANUFACTURER'S RECOMMENDED MAINTENANCE INSTRUCTIONS

ON ALL FINISH MATERIALS. CONTRACTOR TO PROVIDE

GOVERNMENT WITH SHOP DRAWINGS FOR APPROVAL FOR ALL

NEW MATERIALS INSTALLED

6. INTERIOR CONSTRUCTION REQUIRING FINISH / COLOR

SELECTION NOT NOTED WITHIN THE SCHEDULE SHALL BE

SUBMITTED TO THE GOVERNMENT IN WRITING, WITH SAMPLES

OR FINISH / COLORS AVAILABLE, CLEARLY IDENTIFYING ANY THAT

MIGHT BE AT A PREMIUM ABOVE THE PRODUCT BID.

7. ALL PRODUCT SPECIFICATIONS ARE GIVEN TO DEFINE DESIGN,

COLOR AND QUALITY. SUBSTITUTIONS REQUIRE THE PRIOR

APPROVAL OF THE GOVERNMENT. PROPOSED SUBSTITUTIONS

SHALL ADHERE TO THE INTENT OF THE QUALITY, DESIGN, COLOR

AND PATTERN.

8. ALL FIRE HOSE CABINETS, FIRE EXTINGUISHER CABINETS AND

ELECTRICAL PANELS SHALL NOT BE PAINTED AS THEY ARE PRE-

FINISHED.

FINISH PLAN GENERAL NOTES

1. CONTRACTOR TO FOLLOW MANUFACTURER'S PRINTED

INSTALLATION INSTRUCTIONS ON ALL FLOORING

PRODUCTS AND USE THE ADHESIVES, EQUIPMENT /

TOOLS REQUIRED / RECOMMENDED BY THE

MANUFACTURER'S INSTALLATION INSTRUCTIONS.

2. CONTRACTOR TO FOLLOW MANUFACTURER'S PRINTED

INSTRUCTIONS ON PROTECTION OF FLOORING MATERIAL

AFTER INSTALLATION. PROTECT FLOORING AGAINST

MARS, INDENTATIONS AND OTHER DAMAGE FROM

CONSTRUCTION OPERATIONS, PLACEMENT OF

EQUIPMENT AND FIXTURES DURING THE REMAINDER OF

THE CONSTRUCTION PERIOD. USE PROTECTION

METHODS INDICATED OR RECOMMENDED IN WRITING BY

THE FLOOR COVERING MANUFACTURER.

3. CONTRACTOR TO PROVIDE AND INSTALL TRANSITION

STRIPS WHERE DIFFERING MATERIALS ABUT IF NOT

NOTED OTHERWISE. PROVIDE GOVERNMENT WITH

COLOR SAMPLES TO SELECT FROM.

4. FLOOR FINISH CHANGES SHALL OCCUR UNDER THE

DOOR CENTERLINE (OR CENTER OF THE WALL OPENING

IF NO DOOR) BETWEEN ROOMS.

5. WATER BASED NON-SKID FINISH TO BE APPLIED TO ALL

POLISHED CONCRETE.

6. CONTRACTOR TO RECESS FLOOR SLAB WERE

RECESSED WALK OFF GRILLS ARE SPECIFIED, SEE

MANUFACTURER FOR DEPTH.

7. CONTRACTOR SHALL INSTALL SCHLUTER DILEX-BWA

PERIMETER JOINT PROFILE.

8. ALL FLOORING SHOULD CONTINUE UNDER EQUIPMENT

AND VANITIES.

9. PFT-1, PORCELAIN FLOOR TILE TO BE INSTALLED WITH

A 1/3 OFFSET PATTERN. GC TO USE GR-1

FLOOR FINISH NOTES

1. SHOP TO BE CERTIFIED PARTICIPANT IN AWI'S QUALITY

CERTIFICATION PROGRAM. MILLWORK SHOP TO PROVIDE SHOP

DRAWING FOR REVIEW.

2. ALL MILLWORK TO MEET AWI'S PREMIUM STANDARD.

3. 120 DEGREE EURO SELF CLOSING HINGES.

4. MILLWORK, DOORS TO BE FLUSH OVERLAY W/ CONCEALED

EUROPEAN HINGES AND WIRE PULL, CLEAR SATIN FINISH.

MILLWORK SHOP TO PROVIDE SAMPLE TO BE APPROVED BY

GOVERNMENT.

5. ALL MDF AND PLYWOOD PRODUCTS TO CONTAIN NO ADDED

UREA FORMALDEHYDE.

MILLWORK NOTES

1. ALL NEW DOOR FRAMES SHALL BE PAINTED TP-1 ON BOTH SIDE

OF DOORS (UNLESS NOTED OTHERWISE).

DOOR & FRAME NOTES

1. ALL WINDOW SILLS TO BE SOLID SURFACE, SS.

2. ALL WINDOWS TO RECEIVE ALUMINUM BLINDS, AB.

WINDOW NOTES

1. MISCELLANEOUS GRILLS AND ACCESSORIES SHALL BE

PAINTED TO MATCH ADJACENT WALL FINISHES UNLESS

THEY ARE PREFINISHED. CONTRACTOR TO VERIFY PAINT

COLOR WITH GOVERNMENT.

2. SEE FLOOR FINISH PLAN FOR ACCENT PAINT WALL

LOCATIONS.

WALL FINISH NOTES

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

F L O

R

ID

A A

IR

N

A T

IO

N

A L G

U A

R D

J A

C K

S O

N V

IL

L E

A N

G B

F

L O

R

ID

A

P a rk w a y L a n e S u it e

P e a c h tr e e C o rn e rs

L

IC

E N

S E

N U

M B

E R

S

A R

C H

IT

E

C T

U R

E

A A

E N

G

IN

E E

R

IN

G

C o A

N o .8

S o u th a ll

L a n e

S u it e

M a it la n d

F L

T e l:

-2

F L A

C O

A N o

E B

-0

B

IM

/1 F

L A

N G

F -3 c o n v e rs io n H a n g a r/

F

L A

N G

H a n g a r_

A R

C H v .r v t

/2

/2

:5

:5

P M

I-601

R O

O M

F

IN

IS

H

S C

H E

D U

L E

G

E N

E R

A L N

O T

E S th

F

IG

H T

E R

W

IN

G J A

C K

S O

N V

IL

L E

F

L

K D

S

K D

S

A D

S

/2

/2

F -3

R

E P

A

IR

H A

N G

A R

B

L D

G

L S

G A

B -3

S U

B M

IT

T

A L

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

M W

A

FINISH SCHEDULE

SPACE FLOOR WALLS CEILING

REMARKS

ROOM

NO. ROOM NAME MAT. BASE NORTH EAST SOUTH WEST FIN.

156 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

157 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

158 BREAK ROOM EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

159 AVIONICS EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

159A VESTIBULE EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

160 LOCKHEED CPT-1 RB-1 PT-1 PT-2 PT-1 PT-1 ACT-1

161 WOMEN

LOCKERS

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

162 MEN LOCKERS EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

164 S. ENTRY EPTP EPTP PT-1 PT-1 PT-1 PT-1 EXP

165 S. VESTIBULE WLK-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP

167 LOCKHEED /

PMA STORAGE

CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

168 COMM SDT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

169 OVERFLOW

STORAGE

EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

169A VESTIBULE EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

169B ELEC.

170 BREAK ROOM EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

171 STORAGE EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

172 LOCKHEED CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

176 SUPPORT

SHOP

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

176A VESTIBULE EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

177 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

179 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

180 SHOP EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

181 CORRIDOR EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

182 MECH SC RB-1 PT-4 PT-4 PT-4 PT-4 EXP

183 WOMEN

RESTROOM

PFT-1 - PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

CP-1 R1, R3

184 MEN

RESTROOM

PFT-1 - PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

CP-1 R1, R3

185 BATTERY

(CHARGE)

EPTP EPTP PT-4 PT-4 PT-4 PT-4 EXP

186 BATTERY

(STORAGE)

EPTP EPTP PT-4 PT-4 PT-4 PT-4 EXP

FINISH SCHEDULE

SPACE FLOOR WALLS CEILING

REMARKS

ROOM

NO. ROOM NAME MAT. BASE NORTH EAST SOUTH WEST FIN.

101 NORTH

HANGAR BAY

EPFP EPFP PT-5 PT-5 PT-5 PT-5 - R2

102 SOUTH

HANGAR BAY

EPFP EPFP PT-5 PT-5 PT-5 PT-5 - R2

103 WHEEL & TIRE

SHOP

RTF-1 RB-1 PT-4 PT-4 PT-4 PT-4 CP-1

104 W&T STORAGE EPFP EPFP PT-4 PT-4 PT-4 PT-4 EXP

106 EJECTION

SEAT STORAGE

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

106A STORAGE EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

107 EGRESS

OFFICE

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

107A EJECTION

SEAT SHOP

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

108 CANOPY SHOP EPTP EPTP PT-4 PT-4 PT-4 PT-4 CP-1

109 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

110 MECH SC RB-1 PT-4 PT-4 PT-4 PT-4 EXP

111 MEN LOCKERS EPTP EPTP PT-4 PT-4 PT-4 PT-4 CP-1

112 WOMEN

LOCKERS

EPTP EPTP PT-4 PT-4 PT-4 PT-4 CP-1

113A CORRIDOR EPTP EPTP PT-1 PT-1 PT-1 PT-1 CP-1

114 MECH EPTP EPTP PT-4 PT-4 PT-4 PT-4 EXP

115 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

116 FLIGHT LINE LO EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

116A VESTIBULE EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

117A COMM SDT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

118 EQUIP./HAZMAT

STORAGE

EPTP EPTP PT-4 PT-4 PT-4 PT-4 EXP

118A COLLATERAL

STORAGE

EPTP EPTP PT-4 PT-4 PT-4 PT-4 EXP

119 ELEC SC RB-1 PT-4 PT-4 PT-4 PT-4 EXP

120 ELEC SC RB-1 PT-4 PT-4 PT-4 PT-4 EXP

121 N. ENTRY EPTP EPTP PT-1 PT-1 PT-1 PT-1 -

122 N. VESTIBULE WLK-1 RB-1 PT-1 PT-1 PT-1 PT-1 -

123 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

123A OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

123B OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

123C OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

124 APG

SUPERVISORS

CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

125 TRAINING CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

125A VESTIBULE EPFP EPFP PT-1 PT-1 PT-1 PT-1 ACT-1

126 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

126A RADIO

DISPATCH

CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

127 READY ROOM EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

127A VESTIBULE EPTP EPTP PT-1 PT-1 PT-1 PT-1 EXP

127B MECH EPTP EPTP PT-4 PT-4 PT-4 PT-4 EXP

128 WOMEN

LOCKERS

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

129 MENS

LOCKERS

EPTP EPTP PT-4 PT-4 PT-4 PT-4 ACT-1

130 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

131 CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

131A CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

131B VESTIBULE EPFP EPFP PT-1 PT-1 PT-1 PT-1 ACT-1

131C VESTIBULE EPFP EPFP PT-1 PT-1 PT-1 PT-1 ACT-1

131D CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

132 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

134 ELEVATOR

ELECTRICAL

SC RB-1 PT-1 PT-1 PT-1 PT-1 EXP

135 BREAK ROOM LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

136 PILOT DEBRIEF LVT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

138 MULTIPURPOS

E ROOM

LVT-1 RB-1 PT-1 PT-3 PT-1 PT-1 ACT-1

139 STAIRS - RB-1 PT-1 PT-1 PT-1 PT-1 -

139A ELEC EPTP EPTP PT-1 PT-1 PT-1 PT-1 EXP

140 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

141 LOCKHEED CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

142 LOCKHEED CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

143 CORRIDOR EPFP EPFP PT-1 PT-1 PT-1 PT-1 EXP

143A CORRIDOR EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

143B VESTIBULE EPFP EPFP PT-1 PT-1 PT-1 PT-1 ACT-1

144 MEN

RESTROOMS

PFT-1 - PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

ACT-1/CP-1 R1, R3

145 LACTATION

ROOM

CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

147 WOMEN

RESTROOMS

PFT-1 - PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

PT-4/PWT-1/P

WT-2

PT-4/PWT-1/

PWT-2

ACT-1/CP-1 R1, R3

147B JANITOR PFT-1 PTB-1 PT-4 PT-4 PT-4 PT-4 CP-1

148 ELECTRICAL SC RB-1 PT-4 PT-4 PT-4 PT-4 EXP

149 MECHANICAL SC RB-1 PT-4 PT-4 PT-4 PT-4 EXP

152 COMPUTER

AREA

EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

152A VESTIBULE EPTP EPTP PT-1 PT-1 PT-1 PT-1 ACT-1

A

M E

N D

M E

N T

/0

/2

16 A-110A PARTIAL FIRST FLOOR PLAN - AREA A
25 A-201 EXTERIOR ELEVATIONS
27 A-401 ENLARGED FLOOR PLANS
34 A-601 DOOR SCHEDULE
35 A-602 DOOR SCHEDULE
1220605_FLANG HANGAR ID AMENDMENT NO. 2_4-3-24
I-102 - FIRST FLOOR - AREA "B" - INTERIOR FINISH PLAN
I-601 - ROOM FINISH SCHEDULE & GENERAL NOTES
2024-04-03T12:33:37-0400
Marco Migliaro
2024-04-03T12:33:38-0400
Marco Migliaro
2024-04-03T12:33:38-0400
Marco Migliaro
2024-04-03T12:33:38-0400
Marco Migliaro
2024-04-03T12:33:39-0400
Marco Migliaro
2024-04-03T12:33:39-0400
Marco Migliaro
2024-04-03T12:33:40-0400
Marco Migliaro

File details come from the government source that posted it. Updated .