VA263-17-R-1144-021.pdf
PDF 6 MB Posted
- Solicitation number
- VA26317R1144
About this file
VA263-17-R-1144 Attachment 19 of 25_S Drawings Combined (11 Pages).pdf
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
30 x 42
G E
N
R A
L
O
T
S
618-16-111
Project Title
V.A. MEDICAL CENTER
ONE VETERANS DRIVE
MINNEAPOLIS, MN 55417
REGISTRATION NUMBER:
Office of Facilities
Management Drawing Scale
Plot Scale
Drawing Title
Approved: Division Chief
Approved: Service Director
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
o n e -e ig h th i c e f o t
-q u a rt r in c e f o re s n c e f o
-h lf i n c e f o e f o e i n c e f o d i n c e f o n c h e e f o
TRUE NORTH
PLAN NORTH
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENING SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION OR REPORT WAS
PREPARED BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM A DULY
LICENSED PROFESSIONAL ENGINEER UNDER
THE LAWS OF THE STATE OF MINNESOTA
C
U rs
\b c k js
\D m ts
\3
B
D ll_ b c
.r v
/4
/2
:5 :0
P
M
1322- S-010
MJK JSB
Minneapolis VA Health Care Facility
GENERAL STRUCTURAL NOTES
STRUCTURAL
Issue Date DWG. 7 OF 95
A. DESIGN CRITERIA
5. SEISMIC LOADS DETERMINED IN ACCORDANCE WITH THE “BUILDING CODE”.
* SITE CLASSIFICATION ASSUMED AS “CLASS D”, PER IBC 2012 SECTION 1613.3.2
6. LOAD COMBINATIONS IN ACCORDANCE WITH THE “BUILDING CODE” (IBC 2012, SECTION
1605.1).
7. NO PROVISIONS FOR ANY FUTURE BUILDING EXTENSION OR ADDITION HAVE BEEN
MADE IN THE STRUCTURAL DESIGN.
1. “BUILDING CODE” – “INTERNATIONAL BUILDING CODE 2012” (IBC 2012) AS
SUPPLEMENTED BY ASCE 7 “MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES” (2010)
2. LIVE LOADS DETERMINED IN ACCORDANCE WITH THE “BUILDING CODE”.
* PARTITION ALLOWANCE UNIFORMLY DISTRIBUTED LIVE LOAD IS ADDITIVE TO FLOOR
UNIFORMLY DISTRIBUTED LIVE LOADS UNLESS THE MINIMUM SPECIFIED UNIFORMLY
DISTRIBUTED LIVE LOAD EXCEEDS 80 PSF.
** 2000 LB., 1000 LB. AND 300 LB. MINIMUM CONCENTRATED LIVE LOADS ASSUMED TO
BE UNIFORMLY DISTRIBUTED OVER AN AREA OF 2.5 FEET BY 2.5 FEET. 300 LB. MINIMUM
CONCENTRATED LIVE LOAD ON STAIR TREADS APPLIED ON AN AREA OF 2 INCHES BY 2
INCHES.
*** REDUCED TO 15 PSF WHEN COMBINED WITH FLOOR LIVE LOAD.
THE ROOF MINIMUM UNIFORMLY DISTRIBUTED LIVE LOAD HAS NOT BEEN REDUCED.
FLOOR MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS HAVE BEEN REDUCED IN
ACCORDANCE WITH THE “BUILDING CODE”, (IBC 2012, SECTION 1607.10.1).
3. SNOW LOADS DETERMINED IN ACCORDANCE WITH THE “BUILDING CODE”.
4. WIND LOADS DETERMINED IN ACCORDANCE WITH THE “BUILDING CODE”.
LOCATION
MINIMUM
UNIFORMLY
DISTRIBUTED
LIVE LOAD*
CONCENTRATED
LIVE LOAD
OFFICE BUILDINGS:
LOBBIES & FIRST FLOOR CORRIDORS 100 PSF 2000 LB.**
CORRIDORS ABOVE FIRST FLOOR 80 PSF 2000 LB.**
OFFICES 50 PSF 2000 LB.**
HOSPITALS:
LOBBIES & FIRST FLOOR CORRIDORS 100 PSF 2000 LB.
CORRIDORS ABOVE FIRST FLOOR 80 PSF 1000 LB.
OPERATING ROOMS, LABORATORIES 60 PSF 1000 LB.
PATIENT ROOMS 40 PSF 1000 LB.
MECHANICAL EQUIPMENT ROOM (GENERAL) 100 PSF -------
MECHANICAL EQUIPMENT ROOM (HVAC) 125 PSF -------
MECHANICAL TELEPHONE AND RADIO
EQUIPMENT ROOM
150 PSF -------
RESTROOMS (LATRINES) 75 PSF -------
STAIRS AND EXITS 100 PSF 300 LBS. **
STORAGE AREAS (GENERAL):
HEAVY STORAGE 250 PSF -------
LIGHT STORAGE 125 PSF -------
TELEPHONE EXCHANGE ROOMS 150 PSF 2000 LB.**
CENTRAL COMPUTER IT SERVER ROOMS 150 PSF 2000 LB.**
ELEVATOR MACHINE ROOMS 150 PSF -------
FILE ROOMS 150 PSF -------
PUBLIC ROOMS 100 PSF -------
PARTITION ALLOWANCE 15 PSF* -------
ROOFS (MINIMUM) 20 PSF 300 LB.**
INTERSTITIAL LEVELS 25 PSF *** -------
SNOW LOAD PARAMETERS -
GROUND SNOW LOAD P = 50 PSF
TERRAIN CATEGORY C
SNOW EXPOSURE FACTOR C = 1.0 (PARTIALLY EXPOSED)
SNOW THERMAL FACTOR C = 1.0 (ALL STRUCTURES U.N.O.)
RISK CATEGORY IV ESSENTIAL
SNOW IMPORTANCE FACTOR I = 1.2
FLAT ROOF SNOW LOAD P = 42 PSF
RAIN-ON-SNOW SURCHARGE
LOAD
= 0 PSF
WIND LOAD PARAMETERS -
ULTIMATE DESIGN WIND
SPEED
V = 120
MPH
NOMINAL DESIGN WIND SPEED V = 93 MPH
WIND EXPOSURE CATEGORY C
INTERNAL PRESSURE
COEFFICIENT
GC =
+/-0.18
ENCLOSED BUILDING
SEISMIC DESIGN PARAMETERS -
RISK CATEGORY IV
SEISMIC IMPORTANCE FACTOR I = 1.5
MAPPED SPECTRAL RESPONSE
ACCELERATION AT SHORT PERIOD
S = 0.048
ACCELERATION AT PERIOD OF 1 SECOND
S = 0.028
SITE CLASSIFICATION CLASS D*
DESIGN SPECTRAL RESPONSE
S = 0.051
ACCELERATION AT A PERIOD OF 1 SECOND
S = 0.045
SEISMIC DESIGN CATEGORY A
SEISMIC RESPONSE COEFFICIENT C = 0.01
EFFECTIVE SEISMIC WEIGHT W =TBD PER ASCE 7, SECTION 12.7.2
TOTAL SEISMIC DESIGN BASE SHEAR V = C X W
ANALYSIS PROCEDURE USED INDEX INDEX FORCE ANALYSIS (ASCE
7, SECTION 1.4)
DS
D1 g f ult asd pi
B. SOIL PREPARATION AND FOUNDATIONS
1 ALL EXCAVATION, FILL, COMPACTION, AND GRADING OF THE SITE SHALL BE IN
ACCORDANCE WITH THE SPECIFICATIONS, AND OSHA REQUIREMENTS.
2. SOIL SUPPORTED SPREAD FOOTING SHALLOW FOUNDATIONS -
A. DESIGN BEARING PRESSURE (NET) IS 8000 PSF FOR SPREAD FOOTING SHALLOW
FOUNDATIONS BEARING ON UNDISTURBED FIRM SUBGRADE SOIL OR APPROVED
ENGINEERED FILL MATERIAL. DESIGN VALUES AND BEARING MATERIALS SHALL BE
VERIFIED AND APPROVED BY A QUALIFIED LICENSED GEOTECHNICAL ENGINEER.
B. FOUNDATION REINFORCING SHALL BE SUPPORTED FROM ABOVE OR WITH 3 INCH BAR
SUPPORTS AT 4 FEET ON CENTER (MAX.) WHILE DEPOSITING CONCRETE IN FORMS.
C. MOISTURE CONTENT AND COMPACTION IN FOUNDATION EXCAVATIONS SHALL BE
MAINTAINED UNTIL FOUNDATIONS ARE PLACED. FOUNDATIONS SHALL BE POURED AS
SOON AS PRACTICAL AFTER EXCAVATIONS ARE COMPLETED.
C. CAST-IN-PLACE CONCRETE
A. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED 3/4 INCH INSIDE FORMS OR
TOOLED TO 3/8 INCH RADIUS ON SLABS UNLESS NOTED OTHERWISE.
B. SLABS-ON-GRADE SHALL HAVE CONSTRUCTION JOINTS AND CONTROL JOINTS (SAWED
JOINTS) LOCATED AS SHOWN ON THE DRAWINGS. SHOULD THE CONTRACTOR DESIRE TO
DEVIATE FROM THE SLAB ON GRADE JOINT LAYOUT SHOWN, THE CONTRACTOR SHALL
SUBMIT AN ALTERNATE JOINT LAYOUT AS PART OF THE REQUIRED SLAB-ON-GRADE
CONCRETE PLACEMENT, JOINTING, AND CURING PLAN REQUIRED BY GENERAL
STRUCTURAL NOTE C.6. THE ALTERNATE JOINT LAYOUT AND SPACING SHALL BE IN
ACCORDANCE WITH THE RECOMMENDATIONS OF ACI 302.1R "GUIDE FOR CONCRETE
FLOOR AND SLAB CONSTRUCTION", LATEST EDITION. THE CONTRACTOR SHALL LOCATE
AND DIMENSION ALL SLAB-ON-GRADE JOINTS ON THE STEEL REINFORCEMENT SHOP
DRAWINGS.
C. PROVIDE CONSTRUCTION JOINTS IN ACCORDANCE WITH ACI 318. WHERE NECESSARY,
VERTICAL CONSTRUCTION JOINTS IN STRUCTURAL MEMBERS SHALL BE LOCATED WITHIN
THE CENTER ONE-THIRD OF THE SPAN. ALL JOINTS SHALL BE THOROUGHLY CLEANED
AND PURPOSELY ROUGHENED TO 1/4 INCH AMPLITUDE AND COATED WITH AN APPROVED
EPOXY BONDING AGENT PRIOR TO PLACING ADJACENT CONCRETE. CONSTRUCTION
JOINTS IN EXPOSED CONCRETE SHALL HAVE A MAXIMUM SPACING OF 50 FEET.
CONSTRUCTION JOINTS SHALL ALIGN WITH THE NEAREST ADJACENT MASONRY CONTROL
JOINT. NO HORIZONTAL CONSTRUCTION JOINTS WILL BE PERMITTED IN BEAMS, WALLS,
AND SLABS UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS OR APPROVED BY THE
ARCHITECT AND STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN OF ALL FORMING,
TEMPORARY BRACING, AND SHORING.
E. NO ALUMINUM SHALL BE EMBEDDED IN CONCRETE. CONDUITS AND PIPING RUNNING
HORIZONTALLY SHALL NOT BE EMBEDDED IN CONCRETE SLABS-ON-GRADE, ELEVATED
CONCRETE STRUCTURAL SLABS OR WALLS, OR ELEVATED CONCRETE SLABS ON STEEL
DECK. VERTICAL PENETRATIONS THRU ELEVATED SLABS SHALL BE COORDINATED NOT
TO CONFLICT WITH REINFORCING AND SHALL BE LOCATED AND DIMENSIONED ON THE
STEEL REINFORCEMENT AND STEEL DECK SHOP DRAWINGS. PENETRATIONS SHALL NOT
PENETRATE SLAB DROP PANELS OR BEAMS. VERTICAL PENETRATIONS THRU ELEVATED
SLABS SHALL BE SLEEVED OR FORMED ONLY. CORE DRILLING WILL NOT BE ALLOWED.
ALL SLEEVED PENETRATIONS SHALL BE COORDINATED BY THE CONTRACTOR AND
LOCATED AND DIMENSIONED ON THE STEEL REINFORCEMENT AND STEEL DECK SHOP
DRAWINGS. THE NUMBER AND SPACING OF ADJACENT SLEEVES SHALL BE COORDINATED
WITH THE STRUCTURAL ENGINEER OF RECORD PRIOR TO INSTALLATION TO PREVENT
ANY IMPACT ON STRUCTURAL CAPACITY OR PERFORMANCE.
5. CURING FOR CONCRETE SURFACES NOT IN CONTACT WITH FORMS. ONE OF THE
FOLLOWING PROCEDURES SHALL BE APPLIED IMMEDIATELY AFTER COMPLETION OF
PLACEMENT AND FINISHING.
A. APPLICATION OF MOISTURE RETAINING CURING MATERIALS CONSISTING OF BURLAP
BACKED WHITE WATERPROOF SHEET MATERIALS, CONFORMING TO ASTM C171
"STANDARD SPECIFICATION FOR SHEET MATERIALS FOR CURING CONCRETE". CURING
SHALL BE CONTINUED AT LEAST 7 DAYS.
B. APPLICATION OF A CURING COMPOUND CONFORMING TO ASTM C309 "STANDARD
SPECIFICATION FOR LIQUID MEMBRANE FORMING COMPOUNDS FOR CURING CONCRETE".
VOC CONTENT OF THE CURING COMPOUND SHALL NOT EXCEED 100 GRAMS/LITER. THE
COMPOUND SHALL BE APPLIED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE
MANUFACTURER IMMEDIATELY AFTER ANY WATER SHEEN WHICH MAY DEVELOP AFTER
FINISHING HAS DISAPPEARED FROM THE CONCRETE SURFACE. IT SHALL NOT BE USED
ON ANY SURFACE AGAINST WHICH ADDITIONAL CONCRETE OR SUBSEQUENTLY APPLIED
FINISH MATERIAL OF SYSTEM IS TO BE BONDED UNLESS IT IS PROVEN THAT THE CURING
COMPOUND WILL NOT PREVENT PROPER BOND, OR UNLESS POSITIVE MEASURES ARE
TAKEN TO REMOVE IT COMPLETELY FROM AREAS TO RECEIVE BONDED APPLICATIONS.
CURING SHALL BE CONTINUED AT LEAST 7 DAYS.
C. APPLICATION OF ABSORPTIVE MATS OR FABRIC KEPT CONTINUOUSLY MOIST.
6. CONTRACTOR SHALL SUBMIT FOR REVIEW AND COMMENT, A CONCRETE PLACEMENT,
JOINTING, AND CURING PLAN 28 DAYS PRIOR TO BEGINNING ANY CONCRETE
CONSTRUCTION. THE PLAN SHALL INCLUDE AS A MINIMUM THE LOCATION, SEQUENCE,
AND SCHEDULE FOR EACH CONCRETE PLACEMENT. THE CONCRETE JOINTING
LOCATIONS, TYPE, AND MATERIALS SHALL BE IDENTIFIED AND COORDINATED WITH THE
PLACEMENT PLAN AND THE CONCRETE CURING MATERIALS AND DURATIONS SHALL BE
IDENTIFIED AND COORDINATED WITH THE PLACEMENT AND JOINTING PLANS.
7. ALL INTERIOR CONCRETE SLABS-ON-GRADE, ELEVATED STRUCTURAL CONCRETE SLABS,
AND ELEVATED SLABS ON STEEL DECK SHALL RECEIVE A STEEL TROWEL FINISH UNLESS
NOTED OTHERWISE, SPECIFIED, OR REQUIRED BY A SUBSEQUENT FLOOR FINISH SYSTEM
OR MATERIAL.
C. CAST-IN-PLACE CONCRETE
1. ALL STRUCTURAL CAST-IN-PLACE CONCRETE HAS BEEN DESIGNED AND SHALL BE
CONSTRUCTED IN ACCORDANCE WITH THE “BUILDING CODE” AND ACI 318-11 “BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY”.
2. CONCRETE REQUIREMENTS -
A. CAST-IN-PLACE CONCRETE 28-DAY SPECIFIED COMPRESSIVE STRENGTHS AND
PROPERTIES -
B. PROVIDE TYPE I PORTLAND CEMENT MEETING THE REQUIREMENTS OF ASTM C150.
C. FLY ASH ON NATURAL POZZOLAN USED AS ADMIXTURES SHALL CONFORM TO ASTM C618.
D. PROVIDE CONCRETE AGGREGATES CONFORMING TO ASTM C33 FOR NORMAL-WEIGHT
CONCRETE.
PROVIDE CONCRETE AGGREGATES CONFORMING TO ASTM C330 FOR LIGHT-WEIGHT
CONCRETE.
E. WATER USED MIXING CONCRETE SHALL BE POTABLE AND CONFORM TO ASTM C1602.
F. THE USE OF CALCIUM CHLORIDE, ADMIXTURES CONTAINING CHLORIDES AND OTHER
CHLORIDE CONTAINING AGENTS IN CAST-IN-PLACE STRUCTURAL CONCRETE IS
PROHIBITED.
G. CONCRETE CLEAR COVER OVER REINFORCING SHALL BE IN ACCORDANCE WITH ACI 318,
LISTED BELOW, UNLESS NOTED OTHERWISE -
3. CONCRETE REINFORCING SHALL MEET THE FOLLOWING -
A. STEEL REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615
GRADE 60. STEEL REINFORCING BARS REQUIRED TO BE WELDED SHALL CONFORM TO
THE REQUIREMENTS OF ASTM A706 GRADE 60. WELDING OF STEEL REINFORCING BARS
SHALL BE IN ACCORDANCE WITH AWS D1.4-98 “STRUCTURAL WELDING CODE –
REINFORCING STEEL”. WELDING OF REINFORCING OTHER THAN SPECIFIED IS
PROHIBITED. STEEL REINFORCEMENT SHOP DRAWINGS SHALL CLEARLY DENOTE ALL
WELDING REQUIREMENTS FOR REVIEW AND APPROVAL.
B. ALL REINFORCING SHALL BE CONTINUOUS UNLESS NOTED OR INDICATED OTHERWISE.
LAP SPLICES AND EMBEDMENT LENGTHS FOR REINFORCING SHALL BE IN ACCORDANCE
WITH THE "REINFORCEMENT SPLICE AND EMBEDMENT SCHEDULE" AND THE "ACI
STANDARD 90 AND 180 DEGREE HOOK REINFORCEMENT EMBEDMENT SCHEDULE" SHOWN
ON THE STRUCTURAL DRAWINGS UNLESS NOTED OTHERWISE. WHERE REINFOCING BARS
OF DIFFERENT SIZES LAP, PROVIDE A LAP SPLICE LENGTH FOR THE LARGER
REINFORCING BAR SIZE.
C. PROVIDE CORNER BARS IN OUTSIDE FACE OF ALL GRADE BEAMS AND WALLS EQUAL IN
SIZE AND SPACING TO MAIN HORIZONTAL REINFORCING. EXTEND INSIDE FACE
REINFORCING OF ALL GRADE BEAMS AND WALLS TO OUTSIDE FACE AND BEND TO A
STANDARD 90 DEGREE HOOK UNLESS NOTED OTHERWISE.
D. PROVIDE 2-#5 EACH SIDE OF EACH OPENING THROUGH WALLS OR SLABS UNLESS NOTED
OTHERWISE. REINFORCING BARS SHALL EXTEND 24 INCHES PAST THE OPENING.
E. WELDED (PLAIN) WIRE FABRIC REINFORCING SHALL CONFORM TO THE REQUIREMENTS
OF ASTM A1064, FY = 60 KSI. WELDED (DEFORMED) WIRE FABRIC REINFORCING SHALL
CONFORM TO THE REQUIREMENTS OF ASTM A1064, Fy = 60 KSI.
F. WELDED WIRE FABRIC SHALL BE PROVIDED IN FLAT SHEETS. THE USE OF ROLLED
WELDED WIRE FABRIC IS PROHIBITED. WELDED WIRE FABRIC MUST HAVE END LAPS AND
EDGE LAPS OF ONE FULL MESH AND SHALL BE HELD IN PLACE BY WIRING ALL LAPS
SECURELY TOGETHER.
G. STEEL REINFORCEMENT SHOP DRAWINGS SHALL BE SUBMITTED WITH REINFORCING
STEEL DETAILED IN ACCORDANCE WITH ACI PUBLICATION SP-66 (04) "ACI DETAILING
MANUAL - 2004".
H. ALL STEEL REINFORCEMENT SHOWN TO HAVE A 90 DEGREE LEG SHALL CONFORM TO THE
REQUIREMENTS OF A STANDARD ACI 90 DEGREE HOOK UNLESS NOTED OTHERWISE.
4. FORMING AND EMBEDMENTS SHALL MEET THE FOLLOWING -
MIN.
f'c
(PSI)
UNIT
WEIGHT
(PCF)
MAX.
W/C
RATIO
AIR
ENT.
INTERIOR STRUCTURE 4000 145±5 0.50 N.R.
INTERIOR FOUNDATIONS 4000 145±5 0.50 N.R.
INTERIOR SLABS-ON-GRADE 4000 145±5 0.42 N.R.
INTERIOR SLAB ON STEEL DECK 3000 110±5 0.50 N.R.
LOCATION CLEAR COVER (IN.)
CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3
EXPOSED TO EARTH OR WEATHER #6 AND LARGER 2
EXPOSED TO EARTH OR WEATHER #5 AND SMALLER 1-1/2
SLABS, WALLS, JOIST NOT EXPOSED TO WEATHER 3/4
BEAMS AND COLUMNS NOT EXPOSED TO WEATHER 1-1/2
(CONT)
DESCRIPTION DATE
c e f o e f o n c e f o i n c e f o e f o e i n c e f o i n c e f o n c h e e f o
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENING SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
PREPARED BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM A DULY
c c
:1
1322- S-011
Issue Date DWG. 8 OF 95
D. STRUCTURAL STEEL
1. ALL STRUCTURAL STEEL HAS BEEN DESIGNED AND SHALL BE FABRICATED AND
ERECTED IN ACCORDANCE WITH THE “BUILDING CODE”, ANSI/AISC 360-10
“SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” (22 JUNE 2010), AND THE AISC
STEEL CONSTRUCTION MANUAL (14TH EDITION) CONFORMING TO THE PROVISIONS OF
THE LOAD RESISTANCE FACTOR DESIGN (LRFD). STRUCTURAL STEEL HAS BEEN
DESIGNED AND SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH
ANSI/AISC 341-10 “SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS (22 JUNE
2010) WHEN APPLICABLE.
A. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CURRENT OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA) STEEL ERECTION STANDARDS 29-CFR, SUBPART R.
2. STRUCTURAL STEEL SHALL BE FABRICATED IN AN AISC CERTIFIED FABRICATION
PLANT, CATEGORY BU (FORMERLY CATEGORY STD). STRUCTURAL STEEL MUST BE
ERECTED BY AN AISC CERTIFIED ERECTION CATEGORY ACSE.
3. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS NOTED
OTHERWISE ON THE DRAWINGS -
* STRUCTURAL ANCHOR RODS SHALL MEET THE REQUIREMENTS OF A DUCTILE
STEEL ELEMENT PER ACI 318. A DUCTILE STEEL ELEMENT HAS TENSILE TEST
ELONGATION OF AT LEAST 14 PERCENT AND REDUCTION IN AREA OF AT LEAST 30
PERCENT.
4. STRUCTURAL STEEL CONNECTIONS -
A. ALL NON-COMPOSITE AND COMPOSITE STEEL BEAM SHEAR CONNECTIONS SHALL BE
AS SHOWN ON THE “TYPICAL STEEL BEAM CONNECTION SCHEDULE”.
B. BOLTS CONNECTING STRUCTURAL STEEL SHALL BE SHALL BE TWIST-OFF TYPE
TENSION-CONTROL BOLT ASSEMBLIES MEETING THE REQUIREMENTS OF ASTM F1852
AND SHALL CONFORM TO RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING
ASTM A325 OR A490 BOLTS". FOR LOCATIONS WHERE TWIST-OFF TYPE
TENSION-CONTROL BOLT ASSEMBLIES CANNOT BE INSTALLED, BOLTS CONNECTING
STRUCTURAL STEEL SHALL BE ASTM A325-N (BEARING TYPE) HIGH STRENGTH BOLTS.
C. BOLTS SHALL BE INSTALLED IN STANDARD SIZE HOLES UNLESS NOTED OTHERWISE.
DO NOT USE OVERSIZED HOLES OR SLOTTED HOLES FOR ANY CONNECTIONS UNLESS
SPECIFICALLY INDICATED ON THE CONTRACT DOCUMENTS OR APPROVED IN WRITING
BY THE STRUCTURAL ENGINEER OF RECORD.
D. ASTM A325 HIGH STRENGTH BOLTS SHALL BE TIGHTENED "SNUG TIGHT" PER RCSC
“SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS” UNLESS
NOTED OTHERWISE.
E ALL BOLTED CONNECTIONS REQUIRING SLIP CRITICAL TYPE PRETENSIONED BOLTS
SHALL BE INDICATED AS SUCH ON THE STRUCTURAL STEEL SHOP DRAWINGS.
TENSION CONTROL BOLTS SHALL BE USED TO ENSURE PROPER TENSIONING.
5. ALL WELDING FOR STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH AISC 360 AND
AWS D1.1-10 “STRUCTURAL WELDING CODE – STEEL”. ALL WELDS SHALL USE E70XX
ELECTRODES (F = 70 KSI) UNLESS NOTED OTHERWISE. WHEN REQUIRED BY AISC 341,
ALL WELDS USED IN MEMBERS AND CONNECTIONS IN SEISMIC FORCE RESISTING
SYSTEM (SFRS) SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS ON AISC 341
AND AWS D1.8 - 09 "STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT".
6. STEEL FRAMING CONNECTIONS SHALL BE TIGHTENED, COLUMNS SHALL BE LEVELED
AND GROUT SHALL BE IN PLACE BENEATH COLUMN BASE PLATES BEFORE STEEL
DECKING IS ATTACHED TO FRAMING.
7. SPLICES SHALL BE ALLOWED ONLY AT LOCATIONS SPECIFICALLY INDICATED ON THE
STRUCTURAL DRAWINGS UNLESS APPROVED IN WRITING BY THE STRUCTURAL
ENGINEER OF RECORD.
8. ALL COPES, HOLES, OPENINGS AND MODIFICATIONS REQUIRED IN STRUCTURAL
STEEL MEMBERS FOR ERECTION OR THE WORK OF OTHER TRADES SHALL BE SHOWN
ON THE STRUCTURAL STEEL SHOP DRAWINGS AND REQUIRE APPROVAL BY THE
STRUCTURAL ENGINEER OF RECORD PRIOR TO FABRICATION.
9. FIELD MODIFICATIONS (HOLES, LENGTH ADJUSTMENTS, ETC.) TO STRUCTURAL STEEL
IS PROHIBITED WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER OF
RECORD.
10. WHERE NO CAMBER IS INDICATED, FABRICATE STEEL BEAMS SO THAT ANY NATURAL
CAMBER IS UPWARD AFTER ERECTION.
TYPE ASTM GRADE
FY (MIN.)
(KSI)
STRUCTURAL WIDE FLANGE BEAMS AND
COLUMNS (W - SHAPES)
A992 ------- 50
STRUCTURAL TEES (WT - SHAPES) A992 ------- 50
STRUCTURAL CHANNELS AND ANGLES (C, MC,
AND L - SHAPES)
A36 ------- 36
STRUCTURAL PLATES AND BARS (TYPICAL U.N.O.) A36 ------- 36
STRUCTURAL PLATES AND BARS (BEAM COLUMN
CONTINUITY CONNECTIONS AND DOUBLER
PLATES)
A572 50 50
STRUCTURAL PLATES AND BARS (SIDEPLATE
CONNECTIONS)
A572 50 50
RAISED PATTERN FLOOR PLATES A786 ------- 36
STRUCTURAL STEEL PIPE A53 B, TYPE E
OR S
HOLLOW STRUCTURAL SECTIONS (HSS - SHAPES -
RECTANGULAR OR SQUARE)
A500 C 50
HOLLOW STRUCTURAL SECTIONS ( HSS - SHAPES
- ROUND)
A500 C 46
THREADED RODS A36 ------- 26
STRUCTURAL ANCHOR RODS* F1554 ------- 36
STRUCTURAL HIGH STRENGTH BOLTS A325 ------- Fu = 120 KSI
A490 ------- Fu = 150 KSI
HEADED SHEAR STUD CONNECTORS A108 TYPE B 51, Fu = 65
KSI
WITH WELDABILITY SUPPLEMENT S1
& CARBON EQUIVALENT FORMULA
PER ASTM F1554 SECTION 1.5.2.1
E. STEEL DECK
1. STEEL DECKS SHALL COMPLY WITH THE REQUIREMENTS OF THE “BUILDING CODE” AND
THE LATEST EDITION OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS FOR STEEL
DECKS.
2. A. AT SECOND FLOOR, COMPOSITE STEEL DECK SHALL BE 2 INCH DEEP COMPOSITE
STEEL DECK WITH AN UNCOATED DESIGN THICKNESS OF 0.0295 IN. (22 GA.). DECKING
SHALL HAVE A MINIMUM YIELD STRENGTH OF 50 KSI, A MINIMUM Ip OF 0.324 IN.^4/FT., A MINIMUM In OF 0.321 IN.^4/FT., A MINIMUM Sp OF 0.263 IN.^3/FT., AND A MINIMUM Sn OF
0.266 IN.^3/FT.
B. AT INTERSTITIAL LEVEL, COMPOSITE STEEL DECK SHALL BE 1.5 INCH DEEP COMPOSITE
STEEL DECK WITH AN UNCOATED DESIGN THICKNESS OF 0.0358 IN. (20 GA.). DECKING
SHALL HAVE A MINIMUM YIELD STRENGTH OF 50 KSI, A MINIMUM Ip OF 0.186 IN.^4/FT., A MINIMUM In OF 0.222 IN.^4/FT., A MINIMUM Sp OF 0.224 IN.^3/FT., AND A MINIMUM Sn OF
0.231 IN.^3/FT..
C. DECKING SHALL RECEIVE A GALVANIZED FINISH PER SPECIFICATION. DECKING SHALL
BE CONTINUOUS OVER A MINIMUM OF THREE SUPPORTS WITHOUT INTERRUPTION.
D. EACH DECK UNIT SHALL BE ATTACHED TO SUPPORTING MEMBERS AND ADJACENT
PANELS AS FOLLOWS –
FASTEN EDGES OF STEEL DECK AT PERIMETER AND AROUND OPENINGS TO THE
SUPPORTING STRUCTURE WITH 5/8” DIAMETER PUDDLE WELDS AT A MAXIMUM OF 6”
O.C..
WHERE PRESENT, ATTACHMENT OF HEADED SHEAR STUD CONNECTORS THRU THE
COMPOSITE STEEL DECK TO THE SUPPORTING STEEL BEAM CAN REPLACE A PUDDLE
WELD.
3. ALL COMPOSITE STEEL DECK OPENINGS GREATER THAN 6 INCHES WIDE MEASURED
PARALLEL TO THE SUPPORTING MEMBERS SHALL BE REINFORCED OR FRAMED AS
SHOWN ON THE “TYPICAL COMPOSITE STEEL DECK OPENING FRAMING DETAILS”
UNLESS INDICATED OTHERWISE.
4. COMPOSITE STEEL DECK HANGER TAB LOADS SHALL NOT EXCEED 60 LBS. PER
HANGER TAB OR THE DECK MANUFACTURER'S RECOMMENDED ALLOWABLE HANGER
TAB LOAD. IN ADDITION, LOADS ON HANGERS SHALL BE DISTRIBUTED IN SUCH A
MANNER THAT THE TRIBUTARY LOADS FOR EACH HANGER DOES NOT EXCEED 5 PSF.
DO NOT HANG MEP EQUIPMENT AND PIPING DIRECTLY FROM COMPOSITE STEEL DECK
5. ALL WELDING FOR STEEL DECK SHALL BE IN ACCORDANCE WITH AWS D1.3-08,
“STRUCTURAL WELDING CODE –SHEET STEEL”. USE E60XX ELECTRODES (F = 60 KSI)
FOR WELDING STEEL ROOF DECK, COMPOSITE STEEL DECK, AND NON-COMPOSITE
STEEL DECK WITH A THICKNESS OF 0.0295 INCH (22 GA.) OR GREATER TO SUPPORTING
STEEL MEMBERS UNLESS NOTED OTHERWISE.
6. COMPOSITE CONSTRUCTION NOTES -
A. THE COMPOSITE FLOOR SYSTEM INCLUDING COMPOSITE STEEL BEAMS AND
CONCRETE SLABS ON COMPOSITE STEEL DECKS HAVE BEEN DESIGNED FOR
UNSHORED CONSTRUCTION UNLESS NOTED OTHERWISE.
B. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING FOR THE CONCRETE SLABS ON
COMPOSITE STEEL DECK, IF NECESSARY, IN ACCORDANCE WITH THE DECK
MANUFACTURER’S RECOMMENDATIONS FOR THE SPAN AND SPAN CONDITIONS
INDICATED.
C. CONDUITS AND PIPES SHALL NOT BE EMBEDDED IN THE CONCRETE SLABS ON
COMPOSITE STEEL DECK.
D. CONDUITS, PIPES, AND SLEEVES PENETRATING VERTICALLY THROUGH THE CONCRETE
SLABS ON COMPOSITE STEEL DECK SHALL NOT IMPAIR THE STRENGTH OF THE
CONSTRUCTION OR THE COMPLETED COMPOSITE STEEL DECK SYSTEM. ALL
VERTICAL PENETRATIONS THROUGH CONCRETE SLABS ON COMPOSITE STEEL DECK
SHALL BE ACCOMPLISHED USING SLEEVES, CORED PENETRATIONS WILL NOT BE
ALLOWED. THE CONTRACTOR SHALL SUBMIT STEEL DECK SHOP DRAWINGS
INDICATING THE SIZE AND LOCATION OF ALL PENETRATIONS THROUGH THE
CONCRETE SLABS ON COMPOSITE STEEL DECK FOR APPROVAL BY THE STRUCTURAL
ENGINEER PRIOR TO FABRICATION AND CONSTRUCTION OF THE DECKING.
E. STEEL HEADED SHEAR STUD CONNECTORS USED FOR COMPOSITE BEAMS SHALL
CONFORM TO THE REQUIREMENTS OF AWS D1.1-10 "STRUCTURAL WELDING CODE -
STEEL" AND ASTM A29, TYPE B, Fu = 65 KSI, Fy = 51 KSI. PROVIDE STEEL HEADED STUDS
CONNECTORS OF QUANTITY, SIZE, AND LENGTH AS INDICATED ON THE DRAWINGS.
F. STEEL HEADED SHEAR STUD CONNECTORS USED AS SHEAR CONNECTORS FOR
COMPOSITE STEEL BEAMS SHALL BE WELDED AND TESTED IN ACCORDANCE WITH THE
REQUIREMENTS OF AWS D1.1-10.LOCATE AND INSTALL ALL STEEL HEADED SHEAR
STUD CONNECTORS ITHROUGH COMPOSITE STEEL DECK IN THE "STRONG" POSITION
AS DEFINED IN AISC 360.
G. HEADED SHEAR STUD CONNECTORS SHALL BE SPACED EQUALLY ALONG THE
CENTERLINE OF THE STEEL BEAM. THE SPACING OF THE HEADED SHEAR STUD
CONNECTORS ALONG THE LENGTH OF A SUPPORTING STEEL BEAM SHALL NOT
EXCEED 36 INCHES.
H. PROVIDE HEADED SHEAR STUD CONNECTORS AT 36 INCHES ON CENTER FOR ALL
STEEL BEAMS AND GIRDERS SUPPORTING CONCRETE SLABS ON COMPOSITE STEEL
DECK WHERE HEADED SHEAR STUD CONNECTORS ARE NOT INDICATED ON THE
I. PROVIDE STEEL DECK SHOP DRAWINGS SHOWING EXACT LAYOUT OF COMPOSITE
BEAM STEEL HEADED SHEAR STUD CONNECTORS FOR EACH SPAN AND DECK TYPE.
36" WIDE DECK PANEL
NUMBER OF END AND SUPPORT 5/8" DIA. PUDDLE
WELDS (PERPENDICULAR & PARALLEL TO DECK SPAN)
3/8"x1 1/4" ARC SEAM WELD CONNECTIONS EQUALLY
SPACED BETWEEN SUPPORTS
12 IN. O.C.
F. MISCELLANEOUS
10. SPECIAL INSPECTIONS AND STRUCTURAL TESTS SHALL BE PERFORMED IN
ACCORDANCE WITH THE MORE STRINGENT REQUIREMENTS OF THE PROJECT
CONTRACT DOCUMENT DRAWINGS, SPECIFCIATIONS, THE "BUILDING CODE" (AS
DEFINED ON SHEET S-010), AND AS DIRECTED BY THE CONTRACTING OFFICER.
WHEN THE CONSTRUCTION CONTRACTOR IS REQUIRED BY THE GOVERNMENT TO
PROVIDE SPECIAL INSPECTIONS AS PART OF HIS WORK, THE CONTRACTOR SHALL
RETAIN THIRD-PARTY QUALITY ASSURANCE AGENCIES TO CONDUCT THE SPECIAL
INSPECTIONS REQUIRED BY THE "BUILDING CODE". THE INSPECTING AGENCY SHALL
PROVIDE REPORTS FOR THE SPECIAL INSPECTIONS DIRECTLY TO THE GOVERNMENT.
THE SERVICES OF A SPECIAL INSPECTOR OF RECORD (SIOR) SHALL BE RETAINED BY
THE CONTRACTOR AS A THIRD PARTY QUALITY ASSURANCE AGENT. THE SIOR SHALL
BE A LICENSED PROFESSIONAL ENGINEER IN A STATE ACCEPTABLE TO THE AUTHORITY
HAVING JURISDICATION. THE SIOR SHALL SUBMIT QUALIFICATIONS ACCEPTABLE TO
THE AUTHORITY HAVING JURISDICATION. THE DUTIES OF THE SIOR SHALL INCLUDE
ITEMS DESCRIBED IN UFC 3-310-04, SECTION 2-1707.10.
F. MISCELLANEOUS
1. SHOP DRAWINGS SHALL BE ORIGINAL DRAWINGS, PREPARED BY THE CONTRACTOR,
SUBCONTRACTOR, SUPPLIER OR DISTRIBUTOR. REPRODUCTION OF STRUCTURAL
CONTRACT DOCUMENTS AS ERECTION PLANS OR DETAILS WILL NOT BE PERMITTED
AND WILL BE REJECTED WITHOUT REVIEW. ALL SHOP DRAWINGS SHALL BE REVIEWED
AND STAMPED BY THE CONTRACTOR PRIOR TO SUBMITTAL FOR REVIEW.
2. CONCRETE EQUIPMENT PADS (HOUSEKEEPING) REQUIRED FOR MECHANICAL AND
ELECTRICAL EQUIPMENT SHALL MEET THE FOLLOWING REQUIREMENTS:
A. PAD SIZE SHALL BE BASED ON THE REQUIREMENTS OF THE EQUIPMENT SELECTED TO
BE INSTALLED BY THE CONTRACTOR.
B. PAD SIZE SHALL BE A MINIMUM OF 12 INCHES GREATER THAN THE SIZE OF THE
EQUIPMENT IN EACH DIRECTION.
C. PADS LOCATED ON ELEVATED CONCRETE FLOORS SHALL BE A MAXIMUM OF 4 INCHES
THICK.
D. PADS LOCATED ON CONCRETE SLABS-ON-GRADE SHALL BE 4 INCHES THICK UNLESS
NOTED OTHERWISE.
E. PADS LESS THAN 10 INCHES THICK SHALL BE REINFORCED WITH #4 AT 12 INCHES ON
CENTER EACH WAY UNLESS NOTED OTHERWISE.
F. PADS WITH THICKNESS BETWEEN 10 AND 12 INCHES SHALL BE REINFORCED WITH #4
BARS AT 12 INCHES ON CENTER EACH WAY TOP AND BOTTOM UNLESS NOTED
OTHERWISE.
G. PADS SHALL BE ANCHORED TO THE SUPPORTING SLAB AND/OR FOUNDATION WITH #4
DOWELS AT 12 INCHES ON CENTER. DOWELS SHALL BE CAST OR EPOXIED INTO THE
SUPPORTING SLAB AND/OR FOUNDATION.
H. SEE DRAWINGS, SPECIFICATIONS, AND “TYPICAL EQUIPMENT PAD DETAIL” FOR
ADDITIONAL INFORMATION.
DESIGN NOTE: PROVIDE “TYPICAL EQUIPMENT PAD DETAIL” ON THE STRUCTURAL
3. THE CONTRACTOR SHALL DESIGN AND PROVIDE ALL ITEMS REQUIRED FOR ATTACHING
ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PROCESS/MISSION EQUIPMENT AND
ELEMENTS TO THE BUILDING STRUCTURE AND TO RESIST ALL LOADS INCLUDING
ANTITERRORISM/FORCE PROTECTION FORCES IN ACCORDANCE WITH UFC 4-010-01
“MINIMUM ANTI-TERRORISM STANDARDS FOR BUILDINGS” AND SEISMIC LOADS.
ATTACHMENT SHALL BE MADE SO AS NOT TO OVERSTRESS THE STRUCTURAL
MEMBERS. THE CONTRACTOR SHALL COORDINATE THE ATTACHMENTS AND
LOCATIONS OF THE EQUIPMENT AND ELEMENTS AND INCORPORATE THEIR
REQUIREMENTS INTO THE STRUCTURAL STEEL SHOP DRAWINGS. THE SHOP DRAWING
SUBMITTAL SHALL INCLUDE ATTACHMENT CALCULATIONS AND SHALL BE SEALED AND
SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE
PROJECT IS LOCATED. REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL,
AND PROCESS/MISSION DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
4. SUBSTITUTION OF POST-INSTALLED ANCHORS FOR EMBEDDED ANCHORS SHOWN ON
THE DRAWINGS WILL NOT BE PERMITTED UNLESS APPROVED IN WRITING BY THE
STRUCTURAL ENGINEER OF RECORD AND THE CONTRACTING OFFICER PRIOR TO
CONSTRUCTION.
5. THE CONTRACTOR SHALL INCLUDE AND PROVIDE THE FOLLOWING SERVICES -
A. VERIFICATION OF ALL DIMENSIONS, ELEVATIONS, OPENING SIZES, AND EQUIPMENT
WEIGHTS PRIOR TO STARTING WORK AND INCORPORATE THIS INFORMATION INTO THE
PROJECT SHOP AND ERECTION DRAWINGS.
B. VERIFICATION OF ALL DIMENSIONS AND MEMBER SIZES RELATING TO ALL EXISTING
CONSTRUCTION AND CONDITIONS.
C. VERIFICATION OF ALL FLOOR DRAINS, SLOPED FLOORS, FLOOR DEPRESSIONS AND
OFFSETS WITH THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS
PRIOR TO THE SUBMITTAL OF STRUCTURAL STEEL, STEEL DECK, AND CONCRETE
REINFORCEMENT SHOP DRAWINGS.
D. COORDINATE WITH THE OWNER AND REMOVE ALL ABANDONED FOUNDATIONS,
UTILITIES, PIPELINES, ETC. THAT MAY INTERFER WITH THE NEW CONSTRUCTION.
E. THE GENERAL CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWINGS
PRIOR TO SUBMITTAL NOTING CHANGES MADE WHICH DO NOT COMPLY WITH
CONTRACT DOCUMENT DRAWINGS AND SPECIFICATIONS. PRIOR WRITTEN APPROVAL
FROM THE CONTRACTING OFFICER, STRUCTURAL ENGINEER OF RECORD, AND
ARCHITECT SHALL BE REQUIRED FOR ALL DEVIATIONS FROM THE CONTRACT
DOCUMENTS MADE BY THE CONTRACTOR. REQUEST FOR INFORMATION SHALL NOT BE
USED TO INTRODUCE SUBSTITUTIONS, DEVIATIONS, OR CHANGES FROM THE
REQUIREMENTS INDICATED BY THE CONSTRUCTION DOCUMENTS.
F. DESIGN AND PROVIDE TEMPORARY BRACING AND SHORING AS REQUIRED FOR
STABILITY DURING CONSTRUCTION.
6. PLANS, SECTIONS, AND DETAILS SHALL NOT BE SCALED FOR DETERMINATION OF
QUANTITIES, LENGTHS, OR FIT OF MATERIALS.
7. SEE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DESIGN DOCUMENTS FOR SIZE
AND LOCATION OF ALL OPENINGS, SLEEVES, CURBS, PADS, INSERTS, ETC. NOT SHOWN
ON STRUCTURAL DRAWINGS. BEFORE FABRICATION OF MATERIALS, COORDINATE
WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND
SPECIFICATIONS AND PROVIDE ALL MISCELLANEOUS AND STRUCTURAL ITEMS
INDICATED OR REQUIRED TO COMPLETE THE WORK.
8. CONSTRUCTION DOCUMENTS CONSIST OF DRAWINGS AND A SEPARATE BOOK OF
SPECIFICATIONS. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY;
NEITHER IS MEANT TO STAND ALONE FOR ANY PORTION OF THE WORK DESCRIBED
HEREIN. ANY CONFLICT BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE
REPORTED IMMEDIATELY TO THE ARCHITECT/ENGINEER AND THE CONTRACTING
OFFICER.
9. THE DESIGN DOCUMENTS REFLECT THE FINAL COMPLETED STATE OF THE
STRUCTURAL SYSTEMS AND ELEMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL
CONSTRUCTION RELATED ENGINEERING TO INCLUDE BUT NOT BE LIMITED TO
CONSTRUCTION MEANS AND METHODS, TEMPORARY SUPPORTS, SHORING AND
BRACING, TEMPORARY USE OF STRUCTURES, PARTIALLY CONSTRUCTED STRUCTURES
AND INCOMPLETE STRUCTURES. ALL CONSTRUCTION AND RELATED ENGINEERING
SHALL BE IN ACCORDANCE WITH ASCE 37-02 “DESIGN LOADS ON STRUCTURES DURING
CONSTRUCTION”.
G. (NOT USED) POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS HAVE BEEN SPECIFIED AND SHALL BE INSTALLED
IN ACCORDANCE WITH THE "BUILDING CODE", ACI 318-11 APPENDIX D
"ANCHORAGE TO CONCRETE" AND THE CURRENT INTERNATIONAL CODE
COUNCIL EVALUATION SERVICE (ICC-ES) EVALUATION REPORT (ESR).
ANCHORS SHALL MEET THE ACCEPTANCE CRITERIA LISTED BELOW:
A. MECHANICAL ANCHORS IN HARDENED CONCRETE SHALL MEET THE TESTING
AND QUALIFICATION REQUIREMENTS OF ACI 355.2-07 "QUALIFICATION OF
POST-INSTALLED MECHANICAL ANCHORS IN CONCRETE AND COMMENTARY"
AND ICC-ES AC193 "ACCEPTANCE CRITERIA FOR MECHANICAL ANCHORS IN
CONCRETE ELEMENTS".
B. ADHESIVE ANCHORS IN HARDENED CONCRETE SHALL MEET THE TESTING AND
QUALIFICATION REQUIREMENTS OF ACI 355.4-11 "QUALIFICATION OF
POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE AND COMMENTARY" AND
ICC-ES AC308 "ACCEPTANCE CRITERIA FOR ADHESIVE ANCHORS IN CONCRETE
ELEMENTS".
2. SUBSTITUTION REQUESTS FOR POST-INSTALLED ANCHORS NOT SPECIFIED ON
THE CONTRACT DOCUMENTS SHALL BE SUBMITTED TO THE STRUCTURAL
ENGINEER OF RECORD FOR APPROVAL PRIOR TO INSTALLATION.
SUBSTITUTION REQUESTS SHALL INCLUDE CALCULATIONS BEARING THE SEAL
AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE
WHERE THE PROJECT IS LOCATED THAT DEMOSTRATE THE SUBSTITUTED
PRODUCT IS EQUIVALENT TO THE SPECIFIED PRODUCT AND MEETS THE
ACCEPTANCE CRITERIA DESCRIBED ABOVE.
3. SUBSTITUTIONS OF POST-INSTALLED ANCHORS FOR CAST-IN-PLACE ANCHORS
WILL NOT BE PERMITTED UNLESS APPROVED BY THE STRUCTURAL ENGINEER
OF RECORD PRIOR TO INSTALLATION.
4. POST-INSTALLED ANCHORS SHALL HAVE SPECIAL INSPECTIONS IN
ACCORDANCE WITH THE MORE STRINGENT REQUIREMENTS OF THE PROJECT
DRAWINGS AND SPECIFICATIONS, THE "BUILDING CODE", THE PRODUCT
EVALUATION REPORT AND AS DIRECTED BY THE CONTRACTING OFFICER. SEE
STRUCTURAL SPECIAL INSPECTIONS REQUIREMENTS FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
STATEMENT OF SPECIAL INSPECTIONS - STRUCTURAL:
1. THE "STATEMENT OF SPECIAL INSPECTIONS" HAS BEEN PREPARED IN ACCORDANCE WITH THE SPECIAL INSPECTION AND STRUCTURAL TESTING
REQUIREMENTS OF IBC 2012, SECTION 1705.
2. THIS "STATEMENT OF SPECIAL INSPECTIONS" ENCOMPASS THE FOLLOWING DISCIPLINE: STRUCTURAL.
3. THE CONSTRUCTION CONTRACTOR SHALL PROVIDE SPECIAL INSPECTIONS AS PART OF HIS WORK, THE CONTRACTOR SHALL RETAIN THIRD-PARTY
QUALITY ASSURANCE AGENCIES TO CONDUCT THE SPECIAL INSPECTIONS REQUIRED BY THE "BUILDING CODE" FOR THE TYPE OF WORK INDICATED.
4. THE SPECIAL INSPECTOR(S) SHALL BE A QUALIFIED PROFESSIONAL(S) WHO SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE
BUILDING OFFICIAL OR CONTRACTING OFFICER FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL
INSPECTION.
5. SPECIAL INSPECTIONS SHALL BE PERFORMED IN COORDINATION WITH IBC 2012, SECTION 1704.
6. THE SPECIAL INSPECTOR SHALL SUBMIT INSPECTION REPORTS TO THE BUILDING OFFICIAL OR CONTRACTING OFFICER, AND TO THE REGISTERED
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE (STRUCTURAL ENGINEER OF RECORD (SEOR)) DURING CONSTRUCTION FOR VERIFICATION, INCLUDING FINAL REPORTS IN ACCORDANCE WITH IBC 2012, SECTION 1704.2.4
7. THE SPECIAL INSPECTOR(S) SHALL USE THE LATEST ISSUE OF THE STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR THE INSPECTION OF THIS
STRUCTURE. SHOP FABRICATION DRAWINGS SHALL NOT BE USED FOR INSPECTION PURPOSES.
8. THE FOLLOWING TABLES IDENTIFY THE STRUCTURAL MATERIALS, SYSTEMS AND COMPONENTS WHICH ARE TO HAVE SPECIAL INSPECTION.
9. SPECIAL INSPECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH AISC 360-10 CHAPTER N.
TESTING REQUIREMENTS
1. THE CONTRACTOR SHALL EMPLOY ONE OR MORE TESTING AGENCIES TO PROVIDE STRUCTURAL TESTING DURING
CONSTRUCTION.
2. THE TESTING AGENCY SHALL SUBMIT TEST RESULTS TO THE SEOR DURING CONSTRUCTION FOR VERIFICATION, INCLUDING A FINAL REPORT IN ACCORDANCE WITH SECTION 1704.1.2 OF THE IBC 2012.
3. TABLE 1 (BELOW) IDENTIFIES THE STRUCTURAL TESTS REQUIRED FOR THIS PROJECT.
** WHEN DIRECTED BY THE SEOR TO PROVIDE POST-INSTALLED ANCHORAGES THE FOLLOWING GUIDELINES SHALL BE
FOLLOWED:
1. A REPRESENTATIVE OF THE ANCHOR MANUFACTURER OR PROJECT SPECIAL INSPECTOR SHALL BE ON SITE TO OVERSEE THE INSTALLATION OF THE FIRST FOUR ANCHORS FOR EACH TYPE OF ANCHOR INSTALLED. THIS MEASURE SHALL BE TAKEN FOR EACH INSTALLER OF THE ANCHORS. THIS SERVICE IS TYPICALLY PROVIDED FREE BY THE LOCAL
ANCHOR REPRESENTATIVE.
2. THE FIRST FOUR ANCHORS SHALL BE TENSION TESTED ONCE INSTALLATION IS COMPLETE FOR 200% OF THE SERVICE
LEVEL LOAD CAPACITY AS SPECIFIED BY THE SEOR.
c e f o e f o n c e f o i n c e f o e f o e i n c e f o i n c e f o n c h e e f o
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENING SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
PREPARED BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM A DULY
c c
:2
12" = 1'-0"
1322- S-012
SPECIAL INSPECTIONS AND TESTING REQUIREMENTS
Issue Date DWG. 10 OF 95
IBC 2012 - TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
VERIFICATION AND INSPECTION
IN
IO
IC
REFERENCED
STANDARD
IBC
REFERENCE
VERIFICATION
/ INSPECTION
REQUIRED
YES NO N/A
1. INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS,
AND PLACEMENT.
- X ACI 318: 3.5, 7.1-7.7 1910.4 X
2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE
1705.2.2, ITEM 2B.
- X AWS D1.4, ACI 318:
3.5.2
- X
3. INSPECTION OF ANCHORS CAST IN CONCRETE WHERE ALLOWABLE LOADS
HAVE BEEN INCREASED OR WHERE STRENGTH DESIGN IS USED.
- X ACI 318: 8.1.3, 21.2.8 1908.5, 1909.1 X
4. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED CONCRETE
MEMBERS.
- X ACI 318: 3.8.6, 8.1.3,
21.2.8
1909.1 X
5. VERIFYING USE OF REQUIRED DESIGN MIX. - X ACI 318: CH. 4, 5.2-5.4 1904.2,1910.2, 1910.3
X
6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR
STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE.
X - ASTM C 172, ASTM C
31, ACI 318: 5.6, 5.8
1910.10 X
7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
X - ACI 318: 5.9, 5.10 1910.6,1910.7,
1908.8
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND
TECHNIQUES.
- X ACI 318: 5.11-5.13 1910.9 X
9. INSPECTION OF PRESTRESSED CONCRETE:
A. APPLICATION OF PRESTRESSING FORCES. X - ACI 318: 18.20,
ACI 318: 18.18.4
B. GROUTING OF BONDED PRESTRESSING TENDONS IN THE
SEISMIC-FORCE-RESISTING SYSTEM.
X - ACI 318: 18.20,
ACI 318: 18.18.4
10. ERECTION OF PRECAST CONCRETE MEMBERS. - X ACI 318: CH. 16 - X
11. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF
TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF
SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS.
- X ACI 318: 6.2 - X
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE
CONCRETE MEMBER BEING FORMED.
- X ACI 318: 6.1.1 - X
STATEMENT OF SPECIAL INSPECTIONS AND TESTING REQUIREMENTS
IBC 2012 - TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL
STEEL
VERIFICATION AND INSPECTION
1. MATERIAL VERIFICATION OF COLD-FORMED STEEL DECK:
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED
IN THE APPROVED CONSTRUCTION DOCUMENTS
- X APPLICABLE ASTM
MATERIAL
STANDARDS
B. MANUFACTURER'S CERTIFIED TEST REPORTS - X - - X
2. INSPECTION OF WELDING:
A. COLD-FORMED STEEL DECK:
1. FLOOR AND ROOF DECK WELDS. - X AWS D1.3 - X
B. REINFORCING STEEL:
1. VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM
A 706.
- X AWS D1.4 ACI 318,
SECTION 3.5.2
2. REINFORCING STEEL RESISTING FLEXURAL AND AXIAL FORCES IN
INTERMEDIATE AND SPECIAL MOMENT FRAMES, AND BOUNDARY ELEMENTS
OF SPECIAL STRUCTURAL WALLS OF CONCRETE AND SHEAR
REINFORCEMENT.
X - AWS D1.4 ACI 318,
3. SHEAR REINFORCEMENT. X - AWS D1.4 ACI 318,
4. OTHER REINFORCING STEEL. - X AWS D1.4 ACI 318,
a. WHERE APPLICABLE.
b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2 OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND
SHALL BE APPROVED BY THE BUILDING OFFICAL PRIOR TO THE COMMENCEMENT OF WORK.
IBC 2012 - TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION TASK
CONTINUOUS
DURING
TASK LISTED
PERIODICALLY
DURING TASK
LISTED
1. VERIFY MATERIALS BELOW SHALLOW
FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE
DESIGN BEARING CAPACITY.
- X X
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER
DEPTH AND HAVE REACHED PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF
COMPACTED FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES
AND LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
X - X
5. PRIOR TO PLACEMENT OF COMPACTED FILL,
OBSERVE SUBGRADE AND VERIFY THAT SITE HAS
BEEN PREPARED PROPERLY.
IBC 2012 - TABLE 1 - SUMMARY OF REQUIRED STRUCTURAL TESTS
TEST
TESTING
1. CONCRETE:
A. CYLINDER COMPRESSION TESTING - X ASTM C 39 SEC. 1905 X
B. PRECONSTRUCTION TESTING OF SHOTCRETE - X - SEC. 1913 X
2. MASONRY:
A. HOLLOW UNIT BLOCK COMPRESSION TESTS (UNIT
STRENGTH METHOD)
- X ASTM C 90 SEC. 2105 X
B. PRISM COMPRESSION TESTS (PRISM TEST METHOD) - X ASTM C 1314 SEC. 2105 X
3. POST-INSTALLED CONCRETE ANCHORS **:
A. EXPANSION ANCHORS - X ICC-ES AC 193 SEC.1912 X
B. ADHESIVE ANCHORS - X ICC-ES AC 193 SEC. 1912 X
a. WHERE APPLICABLE.
c e f o e f o n c e f o i n c e f o e f o e i n c e f o i n c e f o n c h e e f o
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENING SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
PREPARED BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM A DULY
c c
:2
1322- S-020
STRUCTURAL ABBREVIATIONS
Issue Date DWG. 10 OF 95
STIFF. STIFFENER
STL. STEEL
STRUCT. STRUCTURAL OR STRUCTURE
SUBSTR. SUBSTRUCTURE
SUSP. SUSPEND (ED)
Sx SECTION MODULUS ABOUT X-AXIS
SYM. SYMMETRICAL
SYS. SYSTEM
T TENSION, TOP, TORSION OR TREAD(S)
TB TIE BEAM OR TOP BAR(S)
TBD TO BE DETERMINED
TEMP. TEMPERATURE, TEMPORARY
TENS. TENSION
T.F. TOP FACE
THD. THREAD OR THREADED
THK. THICK
T.L. TOP LAYER OR TOTAL LOAD
T.O. TOP OF
T.O.C. TOP OF CONCRETE
T.O.F. TOP OF FOOTING
T.O.G. TOP OF GRATING
T.O.G.B. TOP OF GRADE BEAM
T.O.M. TOP OF MASONRY
T.O.P. TOP OF PIER, PEDESTAL, OR PARAPET
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TRANS. TRANSVERSE
TYP. TYPICAL
T&B TOP & BOTTOM
UFC UNIFIED FACILITIES CRITERIA (DoD)
U.N.O. UNLESS NOTED OTHERWISE
UNREINF. UNREINFORCED
USACE UNITED STATES ARMY CORPS OF ENGINEERS
U.O.N. UNLESS OTHERWISE NOTED
VAR. VARIES OR VARIABLE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
VOL. VOLUME
V.R. VAPOR RETARDER SYSTEM
VS VERSUS
VSC VERTICAL SLIP CLIP
VST VERTICAL SLIP TRACK
W WEST, WIDTH, OR WIDE
W.C. WEB CONNECTION
WD. WOOD
WF WIDE FLANGE
WP WORKING POINT
W.P.J. WEAKENED PLANE JOINT
W.S. WATERSTOP
WSFC WEB SHEAR FRAMING CONNECTION
WT. WEIGHT
WWF WELDED WIRE FABRIC
W/ WITH
W/C WATER / CEMENT
W/O WITHOUT
X BY
YD. YARD
& AND
@ AT
Ø DIAMETER
# NUMBER
% PERCENT
±, +/- PLUS OR MINUS
MOMENT CONNECTION
BOLTED END PLATE MOMENT CONNECTION
N NORTH OR NEWTON
N.A. NOT APPLICABLE
NDT NON-DESTRUCTIVE TESTING
N.F. NEAR FACE
N.I.C. NOT IN CONTRACT
NO. NUMBER
NOM. NOMINAL
N.R. NOT REQUIRED
N.S. NEAR SIDE
N.T.S. NOT TO SCALE
N.W. NORMAL WEIGHT
NWC NORMAL WEIGHT CONCRETE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OUTSIDE FACE
O.H. OPPOSITE HAND OR OVERHEAD
OPER. OPERATING
OPNG. OPENING(S)
OPP OPPOSITE
OZ. OUNCE(S)
PARA. PARAGRAPH OR PARALLEL
PC PILE CAP OR PIER CAP
P.C. PRECAST CONCRETE
PCC POINT OF COMPOUND CURVATURE
PCF POUNDS PER CUBIC FOOT
PCI PRECAST/PRESTRESSED CONCRETE INSTITUTE
PCY POUNDS PER CUBIC YARD
PED. PEDESTAL
PERF. PERFORATED
PERP. PERPENDICULAR
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLUMB. PLUMBING
PLYWD. PLYWOOD
PRC POINT OF REVERSE CURVATURE
PREFAB. PREFABRICATED
PROJ. PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT. POINT
PVC POLYVINYL CHLORIDE
P/T POST-TENSIONED
QTY. QUANTITY
R RISER(S)
RAD. RADIUS
RAF RAISED ACCESS FLOOR (ING)
RCSC RESEARCH COUNCIL ON STRUCTURAL
CONNECTIONS
R.D. ROOF DRAIN
REF. REFER TO OR REFERENCE
REINF. REINFORCED, REINFORCING, OR REINFORCEMENT
REQ'D. REQUIRED
REQ'MT REQUIREMENT(S)
REV. REVISION
RND. ROUND
RTU ROOF TOP UNIT
S SOUTH OR SECTION MODULUS
S.C. SHEAR CONNECTOR
SCHED. SCHEDULE
SDI STEEL DECK INSTITUTE
SDL SUPERIMPOSED DEAD LOAD
SECT. SECTION
SEOR STRUCTURAL ENGINEER OF RECORD
SF SQUARE FOOT (FEET)
SIM. SIMILAR
SIOR SPECIAL INSPECTOR OF RECORD
S.J. SAWED JOINT
SJI STEEL JOIST INSTITUTE
SLBB SHORT LEG BACK-TO-BACK
SLH SHORT LEG HORIZONTAL
SLV SHORT LEG VERTICAL
Sn SECTION MODULUS (POSITIVE)
S.O.G. SLAB-ON-GRADE
Sp SECTION MODULUS (POSITIVE)
SP. SPACE(S), SPACING
SPEC. SPECIFICATION(S)
SQ. SQUARE
SS STAINLESS STEEL
STD. STANDARD
STGR. STRINGER
H HIGH
HD. ST. HEADED STUD
HK. HOOK
HORIZ. HORIZONTAL
HP HIGH POINT
H.S. HIGH STRENGTH
HSA HEADED STUD ANCHOR(S)
HT. HEIGHT
I MOMENT OF INERTIA
In MOMENT OF INERTIA (NEGATIVE)
Ip MOMENT OF INERTIA (POSITIVE)
Ix MOMENT OF INERTIA ABOUT X-AXIS
IB INTERMEDIATE BAR(S)
IBC INTERNATIONAL BUILDING CODE
I.D. INSIDE DIAMETER
I.F. INSIDE FACE
IN. INCH(ES)
INCL. INCLUDE(D)(ING)
INFO. INFORMATION
INT. INTERIOR OR INTERMEDIATE
J.B. JOIST BEARING
JST. JOIST(S)
JT. JOINT
K KIP(S) (1000 POUNDS)
KCF KIPS PER CUBIC FOOT
Kg KILOGRAM(S)
KLF KIPS PER LINEAL FOOT
kN KILONEWTON(S)
K.O. KNOCK OUT
kPa KILOPASCAL(S)
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L LENGTH, LONG
LB.(S) POUND(S)
LIN. LINEAR
L.L. LIVE LOAD
LLBB LONG LEG BACK-TO-BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LP LOW POINT
LRFD LOAD AND RESISTANCE FACTOR DESIGN
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
LT. LIGHT
L.W. LIGHT-WEIGHT
LWC LIGHT-WEIGHT CONCRETE
M METER(S)
MANUF. MANUFACTURER(S)
MAS MASONRY
MATL. MATERIAL
MAX. MAXIMUM
MBM METAL BUILDING SYSTEMS MANUFACTURER
MBR. MEMBER
MBS METAL BUILDING SYSTEM
M.C. MOMENT CONNECTION(S)
MCJ MASONRY CONTROL JOINT
MECH. MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING,
FIRE PROTECTION
MEZZ. MEZZANINE
MID. MIDDLE
MIN. MINIMUM
MISC. MISCELLANEOUS
MK MARK
ML MASONRY LEDGE
mm MILLILETERS
M.O. MASONRY OPENING
MPH MILES PER HOUR
MTL METAL
MPa MEGAPASCAL
D DEEP, DEPTH
db DIAMETER OF BOLT
D.B. DECK BEARING
D.B.A., DBA DEFORMED BAR ANCHOR
DBL. DOUBLE
DEFL. DEFLECTION
DEG. DEGREE(S)
DEM. DEMOLISH
DET. DETAIL
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION(S)
DK. DECK
D.L. DEAD LOAD
DN DOWN
DO DITTO
DoD DEPARTMENT OF DEFENSE
DP DEEP OR DRILLED PIER
DRN. DRAIN
D.S.J. DOWELED SAW JOINT
D.T.I. DIRECT TENSION INDICATOR
DWG.(S) DRAWING(S)
DWL.(S) DOWEL(S)
E EAST
EA. EACH
ECC ECCENTRICITY
ED. EDITION
E.E. EACH END
E.F. EACH FACE
EIFS EXTERIOR INSULATED FINISH SYSTEM
E.J. EXPANSION JOINT
EL. ELEVATION
ELEC. ELECTRICAL
EMBED. EMBEDDED, EMBEDMENT
ENGR. ENGINEER
ENT. ENTRAINMENT
E.O.D. EDGE OF DECK
EOS, E.O.S. EDGE OF SLAB
EQ. EQUAL
EQUIP. EQUIPMENT
EQUIV. EQUIVALENT
E.W. EACH WAY
EXCAV. EXCAVATE OR EXCAVATION
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
F# FOOTING NUMBER
Fb ALLOWABLE BENDING STRESS
Fc ALLOWABLE COMPRESSIVE STRESS
FD FLOOR DRAIN
FDN. FOUNDATION
FIG. FIGURE
F TO F FACE TO FACE
F/F FACE TO FACE
F.F. FINISHED FLOOR OR FAR FACE
FIN. FINISH(ED)
FLEX. FLEXIBLE
FLR. FLOOR
FP FIREPROOF OR FIREPROOFING
F.S. FAR SIDE
FT. FEET OR FOOT
FTG. FOOTING
Fu SPECIFIED MINIMUM TENSILE STRENGTH
FY SPECIFIED MINIMUM YIELD STRENGTH
F'c SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
F'cr REQUIRED COMPRESSIVE STRENGTH OF CONCRETE
F'm COMPRESSIVE STRENGTH OF MASONRY
GA. GAGE OR GAUGE
GALV. GALVANIZED
GB GRADE BEAM
GB# GRADE BEAM NUMBER
GC GENERAL CONTRACTOR
GEN. GENERAL
GEO GEOTECHNICAL
GF GOVERNMENT FURNISHED
GI GOVERNMENT INSTALLED
GOVT GOVERNMENT
GR. GRADE
GRTG. GRATING
A.B. ANCHOR BOLT(S)
ABV. ABOVE
ACCEL. ACCELERATION
ACI AMERICAN CONCRETE INSTITUTE
ADDNL. ADDITIONAL
ADJ. ADJACENT
AESS ARCHITECTURAL EXPOSED STRUCTURAL STEEL
A.F.F. ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
ALT. ALTERNATE
ALUM. ALUMINUM
ANC. ANCHOR
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX. APPROXIMATE OR APPROXIMATELY
A.R. ANCHOR ROD(S)
ARCH. ARCHITECT OR ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASD ALLOWABLE STRENGTH DESIGN OR ALLOWABLE
STRESS DESIGN
ASTM AMERICAN SOCIETY FOR TESTING MATERIALS
AT/FP ANTITERRORISM FORCE PROTECTION
AVG. AVERAGE
AWS AMERICAN WELDING SOCIETY
B. BOTTOM
BAL. BALANCE
BB BOTTOM BAR(S)
BD BOARD
BEJ BRICK OR BLOCK EXPANSION JOINT
BEL. BELOW
BETW. BETWEEN
B.E.W. BOTTOM EACH WAY
B.F. BOTTOM FACE
BF BRACED FRAME
BFB, B.F.B. BOTTOM FLANGE BRACE
B.F.F. BELOW FINISHED FLOOR
B.L. BOTTOM LAYER
BL. BRICK LEDGE OR BLOCK LEDGE
BLDG. BUILDING
BM.(S) BEAM(S)
B.O. BOTTOM OF
B.O.F. BOTTOM OF FOOTING
B.O.P. BOTTOM OF PIER OR PEDESTAL
B.O.S. BOTTOM OF STEEL
BOT. BOTTOM
BP BASE PLATE
BPL BEARING PLATE
BRCG. BRACING
BRDG. BRIDGING
BRG. BEARING
BRK. BRICK
B.S. BOTH SIDES
BT. BENT
BTM. BOTTOM
B. TO B. BACK TO BACK
B/B BACK TO BACK
C COMPRESSION
C# COLUMN NUMBER
C.C. CENTER TO CENTER
CANT. CANTILEVER
CAT. CATEGORY
CF CONTRACTOR FURNISHED
CFMF CONTRACTOR INSTALLED
CI CONTRACTOR INSTALLED
CIP CAST-IN-PLACE
C.J. CONSTRUCTION JOINT OR CONTROL JOINT
CL. CENTERLINE
CLR. CLEAR
CMU CONCRETE MASONRY UNIT
COEFF. COEFFICIENT
COL. COLUMN
COMP. COMPOSITE OR COMPRESSION
CONC. CONCRETE
CONN. CONNECTION
CONSTR.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.