VA263-17-R-1144-00007001.pdf

PDF 270 KB Posted

Attached to
618-16-111 - Expand Out Patient M/H - Construction 36C26318C0097
Solicitation number
VA26317R1144
Issued by

About this file

VA263-17-R-1144 00007 618-16-111 EOMH Sitewalk RFI Memo #4.pdf

View the file

Other files

File Type Posted
36C26318C0097-000.docx DOCX document
VA263-17-R-1144-00007000.docx DOCX document
VA263-17-R-1144-00006001.pdf PDF
VA263-17-R-1144-00006000.docx DOCX document
VA263-17-R-1144-00005001.docx DOCX document
VA263-17-R-1144-00005000.docx DOCX document
VA263-17-R-1144-00004001.pdf PDF
VA263-17-R-1144-00004000.docx DOCX document
VA263-17-R-1144-00003001.pdf PDF
VA263-17-R-1144-00003000.docx DOCX document
VA263-17-R-1144-00002002.pdf PDF
VA263-17-R-1144-00002000.docx DOCX document
VA263-17-R-1144-00002001.pdf PDF
VA263-17-R-1144-00001000.docx DOCX document
VA263-17-R-1144-025.pdf PDF
VA263-17-R-1144-013.pdf PDF
VA263-17-R-1144-018.pdf PDF
VA263-17-R-1144-023.pdf PDF
VA263-17-R-1144-015.doc DOC document
VA263-17-R-1144-003.pdf PDF
VA263-17-R-1144-005.pdf PDF
VA263-17-R-1144-006.docx DOCX document
VA263-17-R-1144-027.pdf PDF
VA263-17-R-1144-016.pdf PDF
VA263-17-R-1144-026.pdf PDF
VA263-17-R-1144-009.pdf PDF
VA263-17-R-1144-008.pdf PDF
VA263-17-R-1144-002.docx DOCX document
VA263-17-R-1144-022.pdf PDF
VA263-17-R-1144-020.pdf PDF
VA263-17-R-1144-019.docx DOCX document
VA263-17-R-1144-021.pdf PDF
VA263-17-R-1144-011.pdf PDF
VA263-17-R-1144-004.xlsx XLSX spreadsheet
VA263-17-R-1144-012.pdf PDF
VA263-17-R-1144-007.docx DOCX document
VA263-17-R-1144-017.docx DOCX document
VA263-17-R-1144-024.pdf PDF
VA263-17-R-1144-014.pdf PDF
VA263-17-R-1144-010.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pre-bid Site Walk Questions #4

Date: 5/21/18

From: Matthew Heiman, Facilities Engineering Project Section, COR

1. Floor finish plan sheet 1322-I-110 shows CT-1 listed in restroom 1P-102 and could have been mistakenly placed in C1P-109 Corridor. Is CT-1 referencing PCT-1?

a. Correct. Price room 1P-102 as using PCT-1.

2. Tile pattern on sheet 1322-I-601 references various sizes of PCT-3 & PCT-4 however does not appear to be listed in the room finish schedule or drawn on the floor finish plan. What area should these selections be figured for?

a. The tile pattern shown on detail 1/I-601 is for the tile alternate to the terrazzo. PCT-3 and PCT- 4 are specific to this work.

3. There is an alternate that replaces terrazzo flooring with ceramic tile in corridor. What tile selection should be used for this alternate? Is this where the PCT-3/PCT-4 tile pattern would be used?

a. Correct. The tile pattern shown on detail 1/I-601 is for the tile alternate to the terrazzo. PCT-3 and PCT-4 are specific to this work.

4. Keynote 4 on sheet 1332-I-602 indicates wall tile height to 48” AFF which is indicated for rooms 1P- 102/1P-103. Should we figure the same 48” tile height for room 1P-112?

a. Correct, Assume wall tile is to 48” in 1P-112 as well.

File details come from the government source that posted it.