This document is a technical data sheet for Tremco Low Rise Foam Insulation Adhesive, a two-component, solvent-free, elastomeric urethane adhesive used for bonding approved insulations to roof substrates. It is approved for use on a variety of roof decks and insulation types, including gypsum, polyisocyanurate, and polystyrene. The adhesive is available in dual cartridge sets, with a storage life of 18 months when stored properly. Application instructions are provided, including surface preparation, coverage rates, and limitations. The document also includes the physical properties of the adhesive, such as tensile strength, density, and fire resistance ratings.

The related state and local contract opportunity is an RFP for roofing services issued by Washtenaw County and the City of Marlette, Michigan. The RFP does not provide specific details on the requested products or services, but it indicates that the jurisdictions are seeking roofing contractors to perform work within their respective areas.

View the file

Other files

File Type Posted
07 HOT STACK PENETRATION.pdf PDF
10_TPA_FA_FB_PARAPET WALL FLASHING.pdf PDF
17 WOOD CURB.pdf PDF
1_TPA_FA_FB_Factory Fabricated Roof Edge.pdf PDF
22 INSULATION FASTENER DENSITY_4X8 (1).pdf PDF
22 INSULATION FASTENER DENSITY_4X8.pdf PDF
34 LIGHT METAL ROOF EDGE.pdf PDF
37_TPA_FA_FB_Tie in.pdf PDF
Project-Roof 14 TPA Replacement.pdf PDF
Riverside Intermediate School- Roof 14 Walkway.pdf PDF
Roof 14 THERMastic Scope of Work.docx DOCX document
THERMglass_Type_IV.pdf PDF
TPA Prefab Universal Corners.pdf PDF
TPA Walkway Roll.pdf PDF
06 METAL SLEEVE AND STORM COLLAR.pdf PDF
37 ROOF DRAIN.pdf PDF
9_TPA_FA_FB_WALL EXPANSION JOINT.pdf PDF
ASPHALTIC ROOFING SYSTEMS DAILY WATERS.pdf PDF
Polyroof_LV.pdf PDF
Premium_III.pdf PDF
Project-Roof 14 Hot BUR Replacement .pdf PDF
Project-Roof 14 TPA Replacement (1).pdf PDF
Riverside Intermediate School- AOC (1).pdf PDF
Riverside Intermediate School- AOC.pdf PDF
Roof 14 THERMastic Scope of Work (1).docx DOCX document
Sheeting Bond Black.pdf PDF
THERMastic 80 Adhesive.pdf PDF
TPA Coated Metal.pdf PDF
TPA_Single_Ply_Bonding_Adhesive.pdf PDF
TremSEAL Pro (1).pdf PDF
TremSEAL Pro.pdf PDF
Tremco LRF Insulation Application Detail.pdf PDF
15_TPA_FA_FB_Drain.pdf PDF
40_TPA_FA_FB_T_Joint Detail.pdf PDF
33_TPA_FA_FB_TERMINATION AT SLOPED ROOF.pdf PDF
01 AREA DIVIDER.pdf PDF
20_TPA_FA_FB_Curb Flashing.pdf PDF
35 LIGHT METAL ROOF EDGE RAISED.pdf PDF
Ad for Roof 14 Replacement FINAL (1).pdf PDF
Alumanation 301.pdf PDF
BURmastic Composite Ply HT.pdf PDF
Burmesh.pdf PDF
Project-Roof 14 Hot BUR Replacement (1).pdf PDF
RFP Addendum Documents.pdf PDF
Riverside Intermediate Roof 14 Bid Form Addendum UPDATED.pdf PDF
Roof 14 TPA Scope of Work (1).docx DOCX document
Roof 14 TPA Scope of Work.docx DOCX document
TPA Prefab Vent Pipe Boots.pdf PDF
TRA Elastomeric Sheeting.pdf PDF
TREMPrime_QD_Low_Odor.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solvent Free, Fast Setting Insulation Attachment Applied Using a Cartridge Gun

Tremco Low Rise Foam Insulation Adhesive is a two component (1:1 ratio), solvent free, elastomeric urethane adhesive. Tremco Low Rise Foam Insulation Adhesive is asbestos free, extremely low in odor, and does not contain any bitumen.

Tremco Low Rise Foam Insulation Adhesive is a fast-setting, high-performance adhesive used in roofing systems for bonding approved insulations to base sheets, structural roof decks, and other approved insulations.

Refer to UL Roofing Materials and Systems Directory and/or FM Approvals RoofNav® for applicable system configurations.

• HD wood fiber (ASTM C 208, Type 2, Grade II)

• Polyisocyanurate board

• Polystyrene

• Gypsum cover board ASTM C1177 & ASTM C1278

• 4’ x 8’ gypsum roof boards are acceptable

• Asphaltic roof board

• Concrete roof decks

• Cementitious wood fiber decks (Tectum)

• Steel deck

• SBS Modified Bitumen membranes (smooth or granule)

• Asphalt base sheets

• Approved insulations in multi-layer constructions

• Smooth or gravel BUR (remove loose gravel)

Available in dual joined cartridge set (Parts 1 & 2) at 1.5 L (0.40 gal) per set. 4 sets per case for a total of 6L (1.58 gal) per case. Six static mixing tips are provided per each case.

Storage Conditions: Keep material temperatures above 45°F (7°C) and do not exceed 95°F (35°C) during storage. Keep from freezing. Do not store in direct sunlight.

Storage Life: 1.5 years (18 months) in unopened containers when stored in proper warehouse temperatures and conditions.

EQUIPMENT:

Cartridge Unit: Custom battery powered Applicator is recommended. Hand powered cartridge application guns are acceptable for use but require smooth even pressure for continuous bead size.

SURFACE PREPARATION:

General: All work surfaces should be clean, dry, and free of dirt, dust, debris, oils, loose gravel, un-adhered coatings, deteriorated membrane and other contaminants or defects that may result in a surface that is not sound or is uneven.

DESCRIPTION

BASIC USES

APPROVED

INSULATIONS

APPROVED

SUBSTRATES

PACKAGING

STORAGE

APPLICATION

Tremco Low Rise Foam Insulation Adhesive

FEATURES

Solvent Free

2-Component

Non-penetrating attachment

BENEFITS

• VOC free

• Low odor

• Not flammable

• Sets in minutes

• Applied using handheld cartridge gun

• No fastener back out

• No corrosion

• Minimizes installation noise

Tremco Low Rise Foam Insulation Adhesive

APPLICATION

CONTINUED

COVERAGE RATE

LIMITATIONS

PHYSICAL PROPERTIES

Existing roof surfaces (recovers): All loose gravel must be entirely removed from gravel surfaced BUR membranes. This can be achieved by power brooming, dry vacuuming, or wet vacuuming. If wet vacuum is used the roof surface must be allowed to dry completely before applying primer and adhesive. Blisters in the existing roof membrane must be removed to allow insulation boards to lay flat. Prime BUR and smooth APP modified bitumen surfaces with Tremco SP Primer at a coverage rate of 300 to 400 ft2/gal (7.4 to 9.8 m2/L). Primer is not required for granulated modified bitumen membranes. For application over existing coated roof surfaces (e.g. aluminum, white elastomeric, etc.) the coating must be well adhered. Conduct a pull test to verify adhesion.

Vapor retarder surfaces: temporary roof membranes or vapor retarders consisting of asphalt glaze coated felts or new smooth APP or SBS modified bitumen membranes must be primed with Tremprime WB at 200 to 400 ft2/gal (4.9 to 9.8 m2/L). Primer is not required for sand-surfaced SBS membranes.

APPLICATION:

Battery powered single bead applicator: Snap off the molded cap on the top of the adhesive cartridge and screw on the mixing tip. Make sure mixing tip is tight to prevent adhesive leakage. Install the cartridge into the battery powered or pneumatic single bead applicator.

Apply ¼”-1/2” wide adhesive beads to the substrate or insulation board in ribbons spaced a minimum of 12 inches on center (spacing may need to be decreased depending on wind uplift requirements). Install insulation boards immediately into the wet adhesive. Do not allow adhesive beads to skin over before placing the boards. Walk on boards to fully press them into the wet adhesive. Use temporary ballast to assure board corners bond tightly to substrate and provide a flat insulation surface. Adhesive will lock boards down in approximately 5 to 7 minutes (slightly longer under cool ambient conditions). Replace mixing tip if application is interrupted for more than 1 minute as adhesive will cure in the nozzle and prevent proper flow of material. Note: mixing tips for cartridge material should not be used with 5 gal. box material.

Cold Temperature Applications:

Tremco Low Rise Foam Insulation Adhesive may be applied at any cold temperature provided the cartridges have been stored and conditioned at 70°F-85°F (22°C-29°C) for 24 hours prior to use. Cure rate will be slower at these cold temperature, but product will cure within acceptable roofing guidelines.

Based on 12” OC bead spacing;

Cartridges - 4 to 5 SQ per case

• Do not store in direct sunlight or at temperatures above 95°F (35°C).

• Product material temperature must be between 70°F - 85°F (22°C - 29°C) for 24 hours prior to use.

• Do not use with insulation boards larger than 4’ x 4’ (1.2m x 1.2m) (see exceptions in Approved Insulation section).

• Do not use insulation boards which have become warped, cupped, or have poor quality due to improper storage/handling. Insulation boards must lay flat upon the roof substrate.

• Do not apply onto wet or damp substrates.

• Do not puddle or mound the adhesive as this will cause the board to rise excessively and lead to gaps between the decking and substrate.

PROPERTY TYPICAL VALUE TEST METHOD

Tensile Strength Min. 250 psi ASTM D 412

Density 8.5 lbs./gal. ASTM D 1875

Peel Adhesion Min. 17 lbf./in. ASTM D 903

Flexibility Pass @ 70°F ASTM D 816

Flame Spread Index 10 ASTM E 84

Smoke Developed Index 30 ASTM E 84

MAINTENANCE

PRECAUTIONS

TECHNICAL SUPPORT

Your local Tremco Roofing representative can provide you with effective maintenance procedures, which may vary depending upon specific conditions. Periodic inspections, early repairs and preventive maintenance are all part of a sound roof program.

Users must read container labels and Safety Data Sheets for health and safety precautions prior to use.

Your local Tremco Representative, working with the Technical Service Staff, can help analyze conditions and needs to develop recommendations for special applications. The services of the Tremco Research Center, which has earned a unique reputation in weatherproofing technology, complement and extend the service of the Tremco Service Staff.

Tremco Low Rise Foam Insulation Adhesive

Tremco is a US Registered trademark of Tremco CPG Inc.

The information provided on this data page supersedes all previous data concerning this product and its application.

The Statements provided concerning the materials shown are intended solely as a general guide for material usage and are believed to be true and accurate. Since the manner of use is beyond our control, Tremco DOES NOT MAKE NOR DOES IT AUTHORIZE ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE, OR ANY OTHER WARRANTY, GUARANTEE OR REPRESENTATION, EXPRESSED OR IMPLIED, CONCERNING THIS MATERIAL EXCEPT THAT IT CONFORMS TO TREMCO’S PRODUCT SAMPLE. Buyer and user accept the product under those conditions and assume the risk of any failure, injury of person or property and loss or liability resulting from the handling, storage or use of the product, whether or not it is handled, stored, used in accordance with directions or specifications. UNDER NO CIRCUMSTANCE SHALL TREMCO BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM ANY BREACH OF WARRANTY. IN ALL CASES, TREMCO’S LIABILITY IS LIMITED, AT TREMCO’S OPTION, TO THE REPLACEMENT OF GOODS, OR THEIR VALUE, PROVEN TO BE DEFECTIVE IN MANUFACTURING.

www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013

220 Wicksteed Avenue Toronto, Ontario, M4H 1G7 1.800.668.9879 Tremco Roofing and Building Maintenance is part of Tremco Construction Products Group.

File details come from the government source that posted it. Updated .