TPA FB Single Ply Roof System.pdf
PDF 1 MB Posted
- Attached to
- RFP for Riverside Roofing
- Solicitation number
- RFP - MANC - 240000000261
- Issued by
- Washtenaw County, Marlette City, Michigan
About this file
The document is a technical product data sheet for the TPA FB Single Ply Roof System manufactured by Tremco. It provides a detailed description of the product's composition, features, and performance characteristics. The TPA FB Roof Membrane is a white thermoplastic single-ply roof membrane reinforced with a high-strength polyester fabric and backed with a non-woven polyester fleece. The membrane is suitable for a variety of roof system configurations and provides excellent resistance to fire, environmental pollutants, and thermal shock. The product is available in three thicknesses - 45 mil, 60 mil, and 80 mil - and can be installed using either hot or cold adhesive application methods.
The related state and local contract opportunity is a Request for Proposals (RFP) for roofing services issued by Washtenaw County and the City of Marlette in Michigan. The RFP seeks proposals for the replacement of roofs on various government facilities within these jurisdictions. The contract term and any renewal options are not specified in the information provided.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Polyester Fleece Backed Tri Polymer Alloy Thermoplastic Single Ply Roof System
TPA FB Roof Membrane is a white thermoplastic single ply roof membrane which is comprised of an elastomeric tri-polymer alloy based on Elvaloy® and blended with CPE and PVC. TPA FB Roof Membrane is reinforced with a high strength polyester fabric and backed with a non-woven polyester fleece. TPA FB Roof Membrane contains a minimum 25% by weight of Preconsumer recycled content, which is blended into the black compound located below the reinforcing fabric. TPA FB Roof Membrane is asbestos free and exceeds the performance requirements of ASTM D 4434/D4434M, Type IV.
TPA FB Roof Membrane is an elastomeric membrane that accepts roof movement and thermal shock. It is fully adhered in either hot applied bituminous adhesive or in a cold applied bonding adhesive. TPA FB Roof Membrane is lapped and seamed using hot air heat welding equipment.
TPA FB Roof Membrane can be used in situations where other roof systems are not practical due to weight or slope considerations. TPA FB Roof Membrane provides excellent resistance to fire exposure in a variety of roof system configurations. TPA FB Roof Membrane resists a wide range of harmful pollutants, such as acid-rain, falling jet fuel, and other minor industrial pollutants. It can resist exposure to oil, grease, dirt, and the detergents used to remove these contaminants.
As an Energy Star Roof Products Partner, Tremco Inc. has determined this product meets the Energy Star Roof Products Program guidelines for energy efficiency. Energy Star qualification is valid for Roofing products in the United States but not in Canada. Natural Resources Canada (NRCan) has implemented an Energy Star program which currently does not include roofing products.
A white TPA FB single ply roof system meets the requirements of California’s Title 24 Energy Efficiency Standards for Residential and Non-Residential Buildings and has been tested per the standards of the Cool Roof Rating Council.
TPA FB Roof Membrane is available in individual rolls or by the pallet, with 10 rolls/pallet.
White. Custom colors such as gray and tan are available, but minimum order quantities are required.
THICKNESS ROLL SIZE COVERAGE (As Applied) WEIGHT 45 mil (1.14 mm) 76” x 90’ (1930 mm x 27.4 m) 546.5 sq. ft. (50.7 sq.m) 180 lbs. (81.6 kg.)
60 mil (1.52 mm) 76” x 90’ (1930 mm x 27.4 m) 546.5 sq. ft. (50.7 sq.m) 258 lbs. (117 kg.)
80 mil (2.03 mm) 76” x 60’ (1930 mm x 18.2 m) 363.9 sq. ft. (33.8 sq.m) 255 lbs. (102 kg.)
Factory Mutual Loss Prevention Data Sheets:
•1-28 Design Wind Loads •1-29 Above Deck Roof Components •1-49 Perimeter Flashing
Roof replacement usually involves more complexities than new construction roofing.
Contingencies such as rusted or deteriorated decks, rotted wood components, rooftop
DESCRIPTION
BASIC USES
PACKAGING
COLOR
DIMENSIONS/
COVERAGE RATES
REFERENCES
APPLICATION
TPA FB Single Ply Roof System
APPLICATION
CONTINUED
TPA FB Single Ply Roof System equipment which cannot be moved or shut down, and numerous other conditions are often encountered.
The following application information is designed to serve as a general guide. Your local Tremco Representative will prepare detailed specifications based on the condition of your roof.
Structural Deck: Deck must be properly designed and structurally sound.
Drainage: Ponding conditions will adversely affect performance of any roofing system.
Where positive drainage does not exist, water removal from roof surface should be facilitated by lowering drains, and/or installing additional drains, tapered insulation, or an approved lightweight insulating concrete slope system.
Insulation: Insulation must be dry and kept dry. No more insulation shall be installed than can be covered in that day. Use of FAS-n-FREE® Adhesive for solvent free, fastener free insulation attachment is the preferred method of securement unless otherwise specified.
General Installation Procedures: According to job specifications, prepare the surface to be covered:
• Remove loose aggregate.
• Replace areas of wet insulation, deteriorated deck and wood components.
• Provide air seal at perimeter, curbs, and penetration flashings.
• Attach new roof insulation according to job specifications.
• Clean insulation surface of loose dust/debris.
Membrane Placement: Plan the placement of TPA FB Roof Membrane to facilitate the fabrication of the least number of seams. Ensure that water flows over or along, but not against, the exposed edges.
Installation of Adhered System:
• Start at the low point of the roof and position the roll square with the roof edge.
• Apply adhesive in a uniform continuous application onto the approved substrate.
• Allow adhesive to become tacky, but do not allow adhesive to fully dry prior to placing membrane into the adhesive.
• Place membrane into adhesive. Broom immediately.
• Overlap at side lap: 3’’ (76 mm) minimum.
Overlap at end lap: 2” (51 mm)
• Do not apply adhesive over membrane in end lap area. Seal end lap using a 6” (152 mm) strip of TPA Roof membrane (without fleece). Heat weld membrane strip over end lap.
Stagger all end laps.
Hot Applied Adhesive Coverage Rate:
• 25 lbs/SQ (1.25 kg/m2)
• Premium III and THERMastic 80 are recommended as hot applied adhesives
Cold Applied Adhesive Coverage Rate:
• Refer to Single Ply Adhesive matrix for coverage rates.
• Refer to adhesive data page for usage
Membrane Seaming:
• All surfaces must be clean and dry.
• For heat welding, allow the hot air welder to warm up. Insert the nozzle tip of the hot air welded into seam area. Move nozzle at a steady speed along the seam area, immediately applying pressure behind the air nozzle with a Neoprene roller or weighted wheel to ensure positive contact of the heated TPA FB Roof Membrane lap. Minimum width of welded lap shall be 1.5” (38.1 mm) when using an automatic welder. Hand welds shall be a minimum 2”(51 mm) wide.
• Field test heat welded laps to assure proper construction. Perform field test after lap area cools to ambient temperatures. Properly constructed laps will not separate at the lap interface when tested. Consult your Tremco representative for additional information.
Perimeter/Projection Attachment: Provide mechanical attachment of roofing membrane at roof perimeter, walls, expansion joints, and all other projections. Follow the recommendations of Factory Mutual Loss Prevention Data Sheets 1-28, 1-29, and 1-49.
TPA FB Single Ply Roof System
LIMITATIONS
PHYSICAL PROPERTIES
CODES & APPROVALS
MAINTENANCE
PRECAUTIONS
TECHNICAL SUPPORT
Current Approvals:
Your local Tremco Roofing Sales Representative can provide you with effective maintenance procedures which may vary, depending upon specific conditions. Periodic inspections, early repairs and preventative maintenance are all part of a sound roof program.
Users must read container labels and Safety Data Sheets for health and safety precautions prior to use.
Your local Tremco Roofing Sales Representative, working with the Technical Service Staff, can help analyze conditions and needs to develop recommendations for special applications.
PROPERTY TYPICAL VALUE TEST METHOD
Thickness 0.045 in (1.14 mm), 0.060 in (1.52 mm), 0.080 in (2.03 mm) ASTM D 751
Tensile strength 350 lbf (1550N) ASTM D 751
Elongation @ fabric break 35% MD, 33% XMD ASTM D 751
Tear strength 100 lbf (440N) ASTM D 751
Dimensional stability @ 176°F 0.3% @ 6 hrs. ASTM D 1204
Low temperature flexibility -40°F (-40°C) ASTM D 2136 (1998)
Reflectivity 0.86 (initial) ASTM C 1549
Thermal emittance 0.86 (initial) ASTM C 1371
SRI (Solar Reflective Index) 108 (initial) 84 (3-year) ASTM E
Recycled Content 25% Preconsumer
Initial Weathered Solar Reflectance Thermal Emittance Rated Product ID Number Licensed Seller ID Number Classification Production Line
Cool Roof Rating Council ratings are determined for a fixed set of conditions, and may not be appropriate for determining seasonal energy performance. The actual effect of solar reflectance and thermal emittance on building performance may vary.
Manufacturer of product stipulates that these ratings were determined in accordance with the applicable Cool Roof Rating Council procedures.
0.86 0.86
0.70 0.82
0612-0007
• Positive drainage is required.
Tremco is a US Registered trademark of Tremco CPG Inc.
The information provided on this data page supersedes all previous data concerning this product and its application.
The Statements provided concerning the materials shown are intended solely as a general guide for material usage and are believed to be true and accurate. Since the manner of use is beyond our control, Tremco DOES NOT MAKE NOR DOES IT AUTHORIZE ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE, OR ANY OTHER WARRANTY, GUARANTEE OR REPRESENTATION, EXPRESSED OR IMPLIED, CONCERNING THIS MATERIAL EXCEPT THAT IT CONFORMS TO TREMCO’S PRODUCT SAMPLE. Buyer and user accept the product under those conditions and assume the risk of any failure, injury of person or property and loss or liability resulting from the handling, storage or use of the product, whether or not it is handled, stored, used in accordance with directions or specifications. UNDER NO CIRCUMSTANCE SHALL TREMCO BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM ANY BREACH OF WARRANTY. IN ALL CASES, TREMCO’S LIABILITY IS LIMITED, AT TREMCO’S OPTION, TO THE REPLACEMENT OF GOODS, OR THEIR VALUE, PROVEN TO BE DEFECTIVE IN MANUFACTURING.
www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013
220 Wicksteed Avenue Toronto, Ontario, M4H 1G7 1.800.668.9879 Tremco Roofing and Building Maintenance is part of Tremco Construction Products Group.