About this file

This document is a product specification sheet for THERMglass Type IV, a fiberglass ply sheet designed for use as a ply sheet within a modified bitumen or built-up roofing system. The product is intended for application over preformed rigid insulation or base sheets and can be used with various Tremco adhesives. The product is available in 36-inch wide rolls, 180 feet in length, with 500 square feet per roll, and is sold by the pallet with 25 rolls per pallet.

The related state and local contract opportunity is an RFP for Riverside Roofing, issued by Washtenaw County and Marlette City in Michigan. The RFP is seeking roofing services, but does not provide specific details on the project scope, quantities, response dates, or contract term.

View the file

Other files

File Type Posted
20_TPA_FA_FB_Curb Flashing.pdf PDF
35 LIGHT METAL ROOF EDGE RAISED.pdf PDF
Ad for Roof 14 Replacement FINAL (1).pdf PDF
Alumanation 301.pdf PDF
BURmastic Composite Ply HT.pdf PDF
Burmesh.pdf PDF
Project-Roof 14 Hot BUR Replacement (1).pdf PDF
RFP Addendum Documents.pdf PDF
Riverside Intermediate Roof 14 Bid Form Addendum UPDATED.pdf PDF
Roof 14 TPA Scope of Work (1).docx DOCX document
Roof 14 TPA Scope of Work.docx DOCX document
TPA Prefab Vent Pipe Boots.pdf PDF
TRA Elastomeric Sheeting.pdf PDF
TREMPrime_QD_Low_Odor.pdf PDF
TremTred.pdf PDF
05 STANDING SEAM EXPANSION JOINT.pdf PDF
15 BASE SHEET FASTENER_7 INCH.pdf PDF
18_TPA_FA_FB_Expansion Joint Curb.pdf PDF
25_TPA_FA_FB_End Lap.pdf PDF
2_TPA_FA_FB_COATED METAL EDGE.pdf PDF
8_TPA_FA_FB_SURFACE MOUNTED COUNTERFLASHING.pdf PDF
Ad for Roof 14 Replacement FINAL.pdf PDF
RFP Addendum Documents (1).pdf PDF
Riverside Intermediate Roof 14 Bid Form Addendum UPDATED (1).pdf PDF
Riverside Intermediate School- Roof 14 Walkway (1).pdf PDF
TPA FB Single Ply Roof System.pdf PDF
TPAmanual.pdf PDF
Tremco Low Rise Foam Insulation Adhesive.pdf PDF
07 HOT STACK PENETRATION.pdf PDF
10_TPA_FA_FB_PARAPET WALL FLASHING.pdf PDF
17 WOOD CURB.pdf PDF
1_TPA_FA_FB_Factory Fabricated Roof Edge.pdf PDF
22 INSULATION FASTENER DENSITY_4X8 (1).pdf PDF
22 INSULATION FASTENER DENSITY_4X8.pdf PDF
34 LIGHT METAL ROOF EDGE.pdf PDF
37_TPA_FA_FB_Tie in.pdf PDF
Project-Roof 14 TPA Replacement.pdf PDF
Riverside Intermediate School- Roof 14 Walkway.pdf PDF
Roof 14 THERMastic Scope of Work.docx DOCX document
TPA Prefab Universal Corners.pdf PDF
TPA Walkway Roll.pdf PDF
06 METAL SLEEVE AND STORM COLLAR.pdf PDF
37 ROOF DRAIN.pdf PDF
9_TPA_FA_FB_WALL EXPANSION JOINT.pdf PDF
ASPHALTIC ROOFING SYSTEMS DAILY WATERS.pdf PDF
Polyroof_LV.pdf PDF
Premium_III.pdf PDF
Project-Roof 14 Hot BUR Replacement .pdf PDF
Project-Roof 14 TPA Replacement (1).pdf PDF
Riverside Intermediate School- AOC (1).pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A High Performance Fiberglass Type IV Ply Sheet

DESCRIPTION

BASIC USES

PACKAGING

APPLICATION

THERMglass™ Type IV

FEATURES

Consistent quality

Multi-ply system

Maintainable areas

Surfacing options

UL, FM and Florida Building Code Listed

BENEFITS

• Dependable performance

• Non-rotting

•Redundantwaterproofing
•Time-testedreliableinstallationtechniquesofconventionalbuilt-uproofing

• Long service life. Modification to roof-top readily accommodated

• Can be finished with various methods to meet local requirements

• Fire/wind protection

THERMglass™ Type IV is a fiberglass ply sheet that exceeds ASTM D 2178, Type IV.

THERMglass Type IV is designed for use as a ply sheet within a modified bitumen or built-up roofing system for application over preformed rigid insulation or base sheets. It may be used with Premium III or Premium IV Hot-Melt Adhesive or where an extra level of performance is required, THERMastic 80 or THERMastic Elastomeric Hot-Melt Adhesive.

Available in rolls which are 36” (914.4 mm) wide by 180’ (54.86m) in length, 500 ft2/roll (46.4 m2/roll) applied.

Sold by pallet, with 25 rolls per pallet.

General Application Data: Roof replacement usually involves more complexities than new construction roofing. Often encountered are situations such as rusted/deteriorated decks, rotted wood components, rooftop equipment which cannot be moved or shut down, and numerous other conditions.

The following application information is designed to serve as a general guide. Your local Tremco Representative will prepare detailed specifications based upon your roof’s conditions.

Structural Deck: Must be properly designed and structurally sound.

Drainage: Ponding conditions are unacceptable and will adversely affect performance of any roofing system. If positive drainage does not exist, water removal must be facilitated by lowering drains, and/ or installing additional drains, tapered insulation, or Tremco approved lightweight insulating concrete slope system.

Insulation: Insulation must be dry and kept dry. No more insulation shall be installed than can be covered that day.

Installation Procedures: According to particular job specifications, prepare surface to be covered:

• Replace areas of wet insulation, deteriorated deck, and wood components.

• Install roof insulation or base sheet.

Plan placement of THERMglass Type IV Roofing Ply to ensure that water will flow over or along, but not against exposed edges.

Starting at low point of roof, apply uniform and continuous mopping of the specified hot-melt adhesive using a standard roofing mop or Tremco approved felt layer.

Three ply membrane: Start and finish roof membrane along edges, terminations and projections, use starting/finishing strips; 12, 24, and 36” (305, 610, 914 mm) wide plies. Install THERMglass Type IV in shingle fashion.

THERMglass™ Type IV

APPLICATION

CONTINUED

APPLICATION RATE

SURFACING OPTIONS

LIMITATIONS

PHYSICAL PROPERTIES

MAINTENANCE

PRECAUTIONS

TECHNICAL SUPPORT

Overlap starter strips 26” (660 mm) with first ply, then overlap each succeeding ply 24-2/3” (626 mm).

Four ply membrane: Start and finish roof membrane along edges, terminations and projections, use starting/finishing strips: 9, 18, 27, and 36” (229, 457, 685, 914 mm) wide plies.

Install THERMglass Type IV in shingle fashion. Overlap starter strips 29” (737 mm) with first ply, then overlap each succeeding ply 27-1/2” (699 mm).

Interply adhesive: Embed each ply in uniform and continuous mopping of specified hot-melt adhesive. Ply shall never touch ply. Apply specified hot-melt adhesive no more than 10’ (3 m) ahead of each roll. Lightly broom plies from unmopped side to ensure complete adhesion. Overlap previous work 24” (600 mm). Lap ply sheet ends 6” (150 mm). Extend all plies to top edges of all cants and cut excess evenly. Stagger end laps.

Avoid walking on plies until adhesive has cooled.

BUR systems: 25 lb/100 ft2 (1.2 kg/m2) ± 20% Install flashing as specified.

Gravel and smooth surfacing options are available. Consult your local Tremco Representative for specific surfacing options.

• Not intended to perform under ponding conditions. Positive drainage is required.

• Do not apply when ambient temperature prevents installation of hot-melt adhesives within stated application temperature range.

• Do not expose to solvents, oils, or other contaminants harmful to asphaltic materials.

Your local Tremco Roofing Sales Representative can provide you with effective maintenance procedures which may vary, depending upon specific conditions. Periodic inspections, early repairs and preventative maintenance are all part of a sound roof program.

Users must read container labels and Safety Data Sheets for health and safety precautions prior to use.

Your local Tremco Roofing Sales Representative, working with the Technical Service Staff, can help analyze conditions and needs to develop recommendations for special applications.

PROPERTY TYPICAL VALUE TEST METHOD

Breaking strength, min. 44 lbf/in MD (7.70 kN/m), 44 lbf/in XD (7.70 kN/m) ASTM D 146

Pliability, radius bend 1/2” (13mm)no failure

Net dry mass of asphalt impregnated 6.0 lbs/100 ft2 (366 g/m2) ASTM D 146 glass felt, individuals rolls, min.

Mass of desaturated glass felt, min. 1.7 lbs/100 ft2 (83 g/m2) ASTM D 146

Bituminous saturant (asphalt), min. 3.0 lbs/100 ft2 (146 g/m2) ASTM D 146

Ash 70-88% ASTM D 146

Tremco is a US Registered trademark of Tremco CPG Inc.

The information provided on this data page supersedes all previous data concerning this product and its application.

The Statements provided concerning the materials shown are intended solely as a general guide for material usage and are believed to be true and accurate. Since the manner of use is beyond our control, Tremco DOES NOT MAKE NOR DOES IT AUTHORIZE ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE, OR ANY OTHER WARRANTY, GUARANTEE OR REPRESENTATION, EXPRESSED OR IMPLIED, CONCERNING THIS MATERIAL EXCEPT THAT IT CONFORMS TO TREMCO’S PRODUCT SAMPLE. Buyer and user accept the product under those conditions and assume the risk of any failure, injury of person or property and loss or liability resulting from the handling, storage or use of the product, whether or not it is handled, stored, used in accordance with directions or specifications. UNDER NO CIRCUMSTANCE SHALL TREMCO BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM ANY BREACH OF WARRANTY. IN ALL CASES, TREMCO’S LIABILITY IS LIMITED, AT TREMCO’S OPTION, TO THE REPLACEMENT OF GOODS, OR THEIR VALUE, PROVEN TO BE DEFECTIVE IN MANUFACTURING.

www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013

220 Wicksteed Avenue Toronto, Ontario, M4H 1G7 1.800.668.9879 Tremco Roofing and Building Maintenance is part of Tremco Construction Products Group.

File details come from the government source that posted it. Updated .