About this file

The provided document is a Scope of Work (SOW) for the Riverside Intermediate Roof 14 TremPly TPA FB Replacement project located in the state of Michigan, specifically in Washtenaw County and Marlette City. The SOW outlines the key requirements for the roofing project, including obtaining necessary permits, setting up safety measures, removing the existing roofing system, installing new insulation and coverboard to achieve an R-30 rating, and installing a 60 mil fully adhered Tremply TPA FB 60 mil system. Additionally, the SOW calls for the installation of new counter flashings, coping caps, and TPA walkways, as well as a 20-year manufacturer's quality assurance warranty with scheduled inspections.

The SOW is related to a Request for Proposal (RFP) for the Riverside Roofing project, which is being issued by the state of Michigan and involves the jurisdictions of Washtenaw County and Marlette City. The RFP does not provide any additional details regarding pricing terms, set asides, incumbents, funding requirements, or other salient information.

View the file

Other files

File Type Posted
17 WOOD CURB.pdf PDF
1_TPA_FA_FB_Factory Fabricated Roof Edge.pdf PDF
Sheeting Bond Black.pdf PDF
15_TPA_FA_FB_Drain.pdf PDF
40_TPA_FA_FB_T_Joint Detail.pdf PDF
RFP Addendum Documents.pdf PDF
Burmesh.pdf PDF
37 ROOF DRAIN.pdf PDF
BURmastic Composite Ply HT.pdf PDF
33_TPA_FA_FB_TERMINATION AT SLOPED ROOF.pdf PDF
01 AREA DIVIDER.pdf PDF
RFP Addendum Documents (1).pdf PDF
Riverside Intermediate School- Roof 14 Walkway (1).pdf PDF
22 INSULATION FASTENER DENSITY_4X8 (1).pdf PDF
15 BASE SHEET FASTENER_7 INCH.pdf PDF
18_TPA_FA_FB_Expansion Joint Curb.pdf PDF
TPA FB Single Ply Roof System.pdf PDF
Riverside Intermediate Roof 14 Bid Form Addendum UPDATED (1).pdf PDF
TPA Prefab Vent Pipe Boots.pdf PDF
Riverside Intermediate Roof 14 Bid Form Addendum UPDATED.pdf PDF
TREMPrime_QD_Low_Odor.pdf PDF
Roof 14 THERMastic Scope of Work.docx DOCX document
TremTred.pdf PDF
Alumanation 301.pdf PDF
Ad for Roof 14 Replacement FINAL (1).pdf PDF
35 LIGHT METAL ROOF EDGE RAISED.pdf PDF
Project-Roof 14 Hot BUR Replacement (1).pdf PDF
Ad for Roof 14 Replacement FINAL.pdf PDF
2_TPA_FA_FB_COATED METAL EDGE.pdf PDF
10_TPA_FA_FB_PARAPET WALL FLASHING.pdf PDF
Tremco Low Rise Foam Insulation Adhesive.pdf PDF
Roof 14 TPA Scope of Work.docx DOCX document
TPA Prefab Universal Corners.pdf PDF
TPA Walkway Roll.pdf PDF
07 HOT STACK PENETRATION.pdf PDF
22 INSULATION FASTENER DENSITY_4X8.pdf PDF
34 LIGHT METAL ROOF EDGE.pdf PDF
Project-Roof 14 TPA Replacement.pdf PDF
20_TPA_FA_FB_Curb Flashing.pdf PDF
37_TPA_FA_FB_Tie in.pdf PDF
Riverside Intermediate School- Roof 14 Walkway.pdf PDF
THERMglass_Type_IV.pdf PDF
05 STANDING SEAM EXPANSION JOINT.pdf PDF
25_TPA_FA_FB_End Lap.pdf PDF
8_TPA_FA_FB_SURFACE MOUNTED COUNTERFLASHING.pdf PDF
TPAmanual.pdf PDF
TRA Elastomeric Sheeting.pdf PDF
TremSEAL Pro.pdf PDF
Tremco LRF Insulation Application Detail.pdf PDF
TremSEAL Pro (1).pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Riverside Intermediate Roof 14 TremPly TPA FB Replacement Scope of Work

1. Obtain all necessary permits.

2. Set up safety per OSHA guidelines.

3. Remove existing roofing system down to the structural decking.

4. Mechanically fasten the first layer is polyisocyanurate insulation and adhere all subsequent insulation and 1/2” coverboard in Low Rise Foam Insulation Adhesive to reach R-30.

5. Install 60 mil a fully adhered Tremply TPA FB 60 mil system in TPA Single Ply Bonding Adhesive.

6. Install TPA walkways to match drawings.

7. Install new 24-gauge kynar coated steel/ aluminum counter flashings and flashings to match existing.

8. Install new 24-gauge kynar coated steel/ aluminum coping caps to match existing.

9. Provide manufacturer’s 20-year Quality Assurance warranty that includes inspections during years 2, 5, 10 and 15. Inspections shall include online report of findings and recommended maintenance.

image1.png

File details come from the government source that posted it. Updated .