Alumanation 301.pdf

PDF 1 MB Posted

Attached to
RFP for Riverside Roofing
Solicitation number
RFP - MANC - 240000000261
Issued by
Washtenaw County, Marlette City, Michigan

About this file

The provided document is a technical data sheet for Alumanation 301, a premium reflective fibered aluminum coating product manufactured by Tremco. The document outlines the product's key features, basic uses, packaging, storage requirements, application instructions, physical properties, and spray equipment recommendations.

The related state and local contract opportunity is an RFP for roofing services in Washtenaw County and Marlette City, Michigan. The RFP seeks proposals for roof maintenance and repair work, and contractors must comply with the technical specifications and application guidelines provided in the Alumanation 301 data sheet. No further details are provided about the scope, quantities, timelines, or award criteria for this contract opportunity.

View the file

Other files

File Type Posted
20_TPA_FA_FB_Curb Flashing.pdf PDF
35 LIGHT METAL ROOF EDGE RAISED.pdf PDF
Ad for Roof 14 Replacement FINAL (1).pdf PDF
BURmastic Composite Ply HT.pdf PDF
Burmesh.pdf PDF
Project-Roof 14 Hot BUR Replacement (1).pdf PDF
RFP Addendum Documents.pdf PDF
Riverside Intermediate Roof 14 Bid Form Addendum UPDATED.pdf PDF
Roof 14 TPA Scope of Work (1).docx DOCX document
Roof 14 TPA Scope of Work.docx DOCX document
TPA Prefab Vent Pipe Boots.pdf PDF
TRA Elastomeric Sheeting.pdf PDF
TREMPrime_QD_Low_Odor.pdf PDF
TremTred.pdf PDF
07 HOT STACK PENETRATION.pdf PDF
10_TPA_FA_FB_PARAPET WALL FLASHING.pdf PDF
17 WOOD CURB.pdf PDF
1_TPA_FA_FB_Factory Fabricated Roof Edge.pdf PDF
22 INSULATION FASTENER DENSITY_4X8 (1).pdf PDF
22 INSULATION FASTENER DENSITY_4X8.pdf PDF
34 LIGHT METAL ROOF EDGE.pdf PDF
37_TPA_FA_FB_Tie in.pdf PDF
Project-Roof 14 TPA Replacement.pdf PDF
Riverside Intermediate School- Roof 14 Walkway.pdf PDF
Roof 14 THERMastic Scope of Work.docx DOCX document
THERMglass_Type_IV.pdf PDF
TPA Prefab Universal Corners.pdf PDF
TPA Walkway Roll.pdf PDF
06 METAL SLEEVE AND STORM COLLAR.pdf PDF
37 ROOF DRAIN.pdf PDF
9_TPA_FA_FB_WALL EXPANSION JOINT.pdf PDF
ASPHALTIC ROOFING SYSTEMS DAILY WATERS.pdf PDF
Polyroof_LV.pdf PDF
Premium_III.pdf PDF
Project-Roof 14 Hot BUR Replacement .pdf PDF
Project-Roof 14 TPA Replacement (1).pdf PDF
Riverside Intermediate School- AOC (1).pdf PDF
Riverside Intermediate School- AOC.pdf PDF
Roof 14 THERMastic Scope of Work (1).docx DOCX document
Sheeting Bond Black.pdf PDF
THERMastic 80 Adhesive.pdf PDF
TPA Coated Metal.pdf PDF
TPA_Single_Ply_Bonding_Adhesive.pdf PDF
TremSEAL Pro (1).pdf PDF
TremSEAL Pro.pdf PDF
Tremco LRF Insulation Application Detail.pdf PDF
15_TPA_FA_FB_Drain.pdf PDF
40_TPA_FA_FB_T_Joint Detail.pdf PDF
33_TPA_FA_FB_TERMINATION AT SLOPED ROOF.pdf PDF
01 AREA DIVIDER.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Premium reflective fibered aluminum coating

Alumanation 301 is a premium grade, high solids, metallic pigmented, industrial maintenance coating formulated from specially processed asphaltic liquids, non-drying oils, a proprietary blend of natural and synthetic fibers, and aluminum pigment. It is formuated to meet ASTM D2824 Standard Specification for Aluminum-Pigmented Asphalt Roof Coatings, Nonfibered, and Fibered without Asbestos.

Alumanation 301 is used for rustproofing and weatherproofing metal roofs, smooth BUR and modified bitumen roof systems.

5 gal (18.9 L) pail, 55 gal (208.1 L) drum

Silver

Brush, Roller, Spray

12 months shelf life in unopened containers when properly stored.

Recommended storage conditions are indoors in a ventilated, dry area removed from heat, open flame, ignition sources and direct sunlight. Storage temperatures should range from 60-70°F (15- 21°C) and must not drop below 32°F (0°C) or exceed 110°F (43°C).

On the job site, materials should remain on the pallet until use and be stored in a shaded, ventilated area. Materials should be covered with a light-colored, reflective tarp for protection against the elements. Allow for adequate air flow inside the pallets.

Shelf life could be affected if the product is not stored properly.

Surface Preparation: Surface must be clean, dry, in sound condition, and free of dirt, debris, and contaminants. Rust must be abraded until it no longer exhibits flaking or chalking. Wet insulation must be identified and replaced. Deficient areas of existing system must be repaired. All repairs should be made with like materials matching the existing components and allowed to properly cure prior to application of liquid-applied products.

Mixing:

Pails: Use a heavy duty corded power drill with Jiffy Mixer mixing blade. Mix until product is consistent in appearance and viscosity. Do not thin.

Drums: Use industrial drum mixing equipment to mechanically mix each container. Mix until product is consistent in appearance and viscosity. Do not thin.

DESCRIPTION

BASIC USES

PACKAGING

COLOR

GRADE

STORAGE

APPLICATION

Alumanation® 301

FEATURES

Proven Performance

One Coat Application

Rust Inhibitor

One Component

Cool Weather Applications

BENEFITS

• Successfully used for over 70 years

• Fewer labor steps; Does not require primer

• Can prevent future oxidation of existing rust

• No mixing errors; No extra labor steps

• Can be installed at 40°F (4.4°C) and rising

ROOF SUBSTRATES/

SURFACES APPLICATION CHART

COVERAGE RATES

TEMPERATURE

RECOMMENDATIONS

SPRAY EQUIPMENT

RECOMMENDATIONS

CLEAN UP

LIMITATIONS

PHYSICAL PROPERTIES

• Coverage rates are listed at minimum recommended rates. The application surface can affect the necessary coverage rate.

• Additional surface area must be accounted for on applications over corrugated or standing seam metal substrates. Coverage may require an additional 15-25% depending on profile.

Min Ambient: 40°F (4.4°C) Max Ambient: 110°F (43.3°C)

• Minimum temperatures must be rising following application

• Do not apply when dew point is within 5°F (2.77°C) of ambient temperatures

• Do not apply when precipitation, fog or dew is imminent prior to cure of the product

• Must use heavy duty or industrial grade spray tips

• Properly clean and maintain spray equipment before, during and after use

• Equipment should be properly grounded during use

Mineral Spirits/Xylene

• Not recommended for use over the following:

Roof Decks: Cementitious wood fiber, metal, poured-in-place gypsum, structural lightweight or lightweight insulating concrete, and wood decks (includes plywood, tongue and groove, etc.).

Products/Systems: Asphalt-based or coal tar gravel surfaced BUR systems, clay tile, expanded or extruded polystyrene insulation, fluoropolymer finished metal, shingles, silicone-based products, and tar-based products.

• Not for use under continuous immersion

PROPERTY TYPICAL VALUE TEST METHOD

Low Temperature Flexibility Pass ¼” mandrel @ 32°F (0°C) ASTM D1737

Metallic Content Min. 15% ASTM D2824

Salt Spray - 100 hrs No corrosion ASTM B117

Reflectance Initial - 0.66, 3 Yr Aged - 0.49 ASTM C1549

Emittance Initial - 0.39, 3 Yr Aged - 0.52 ASTM C1371

SRI Initial - 65, 3 Yr Aged - 42

Solids Content - Volume 47% ASTM D6511

Solids Content - Weight 61% ASTM D6511

VOC 321 g/L

General Guidelines Component Pressure Tip Size Flow Rate Filters Hose Type WHIP Product Temp One-Component 2,500 psi .039 - .049 1.6 - 2.6 gpm Remove High Pressure ¼” High Pressure Ambient

Product Type Product Name BUR - Smooth MB - Smooth MB - Granule Metal Detailing Product Geogard LO Base Coat Geogard Seam Sealer

Geogard Seam Sealer 3-Course: 30-65 ln ft / gal 3-Course: 30-65 ln ft / gal 3-Course: 30-65 ln ft / gal 3-Course: 30-65 ln ft / gal

TremLastic S Back-Brush: 60-100 ln ft / gal

(not for use on metal) Fasteners: 200-250 / gal

Reinforcement Permafab

Rapid-Set Reinforcing Fabric Approx. 300 ln ft / roll Approx. 300 ln ft / roll Approx. 300 ln ft / roll Approx. 300 ln ft / roll

(for use with TremLastic S)

Top Coat Alumanation 301 2½ gals / SQ (40 wet mils) 2½ gals / SQ (40 wet mils) 2½ gals / SQ (40 wet mils) 2 gals/SQ (32 wet mils)

Tremco is a US Registered trademark of Tremco CPG Inc.

The information provided on this data page supersedes all previous data concerning this product and its application.

The Statements provided concerning the materials shown are intended solely as a general guide for material usage and are believed to be true and accurate. Since the manner of use is beyond our control, Tremco DOES NOT MAKE NOR DOES IT AUTHORIZE ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE, OR ANY OTHER WARRANTY, GUARANTEE OR REPRESENTATION, EXPRESSED OR IMPLIED, CONCERNING THIS MATERIAL EXCEPT THAT IT CONFORMS TO TREMCO’S PRODUCT SAMPLE. Buyer and user accept the product under those conditions and assume the risk of any failure, injury of person or property and loss or liability resulting from the handling, storage or use of the product, whether or not it is handled, stored, used in accordance with directions or specifications. UNDER NO CIRCUMSTANCE SHALL TREMCO BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM ANY BREACH OF WARRANTY. IN ALL CASES, TREMCO’S LIABILITY IS LIMITED, AT TREMCO’S OPTION, TO THE REPLACEMENT OF GOODS, OR THEIR VALUE, PROVEN TO BE DEFECTIVE IN MANUFACTURING.

CODES & APPROVALS

MAINTENANCE

PRECAUTIONS

TECHNICAL SUPPORT

Florida Building Code

Your local Tremco Roofing sales representative can provide you with effective maintenance procedures which may vary, depending upon specific conditions. Periodic inspections, early repairs and preventive maintenance are all part of a sound roof program.

Users must read container labels and Safety Data Sheets for health and safety precautions prior to use.

Your local Tremco Roofing sales representative, working with the Technical Service Staff, can help analyze conditions and needs to develop recommendations for special applications.

www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013

220 Wicksteed Avenue Toronto, Ontario, M4H 1G7 1.800.668.9879 Tremco Roofing and Building Maintenance is part of Tremco Construction Products Group.

File details come from the government source that posted it. Updated .