Tech Drawings T300-T500.pdf
PDF 13 MB Posted
- Attached to
- 36C77623B0047 - Y1DA--657A5-21-700 EHRM Infrastructure Upgrades Construction Marion, IL VAMC
- Solicitation number
- 36C77623B0047_1
About this file
This document contains details of a federal contract opportunity for infrastructure upgrades at a Veterans Affairs Medical Center in Marion, Illinois. The solicitation number is 36C77623B0047_1 for contract 36C77623B0047 to provide EHRM Infrastructure Upgrades Construction at the Marion VA Medical Center. The opportunity was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The file also includes technical drawings related to the project. Key work under this contract will involve upgrading infrastructure systems to support electronic health record management at the Marion VAMC. The response deadline and anticipated award date are not specified.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TR
107125 SF
TR
8-107
STORAGE
STORAGE
4A
STORAGE
TR
4A
4A
R.R.
103A
OFFICE
103B
R.R.
103A
OFFICE
103B
GENERAL PLAN NOTES
1. CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
TELECOMMUNICATIONS WALL-MOUNT RACK, 36"H x 26"W x 30"D, VENTED, SOLID WALL TYPE. TO BE
CAGED PER PHYSICAL SECURITY REQUIREMENTS.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO TELECOMMUNICATIONS ENCLOSURE AFTER CUT-OVER.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - BLDG
8, 13, 14
NR 185 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-300
8, 13, 14
SPUR #: 2114
N
1 1/4" = 1'-0"
BLDG 8 LEVEL 1 - FLOOR PLAN
N
2 1/4" = 1'-0"
BLDG 8 LEVEL 1 - FLOOR PLAN
N
3 1/4" = 1'-0"
BLDG 13 BASEMENT - DEMO
N
4 1/4" = 1'-0"
BLDG 13 BASEMENT - FLOOR PLAN
N
5 1/4" = 1'-0"
BLDG 14 LEVEL 2 - DEMO
N
6 1/4" = 1'-0"
BLDG 14 LEVEL 2 - FLOOR PLAN
FINAL BID DOCUMENTS
204184
GENERAL PLAN NOTES
1. CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
TELECOMMUNICATIONS WALL-MOUNT RACK, 36"H x 26"W x 30"D, VENTED, SOLID WALL TYPE. TO BE
CAGED PER PHYSICAL SECURITY REQUIREMENTS.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
TR
101D
TELEPHONE
CLOSET
105C
OFFICE SPACE
105A
TELEPHONE
CLOSET
105C
TR
105D
OFFICE SPACE
105A
105D
5A
OI+T
TOILET
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 15, 16
NR 186 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-301
15 ,16
SPUR #: 2114
N
2 1/4" = 1'-0"
BLDG 15 LEVEL 1 - FLOOR PLAN
N
3 1/4" = 1'-0"
BLDG16 LEVEL 1 - DEMO PLAN
N
4 1/4" = 1'-0"
BLDG 16 LEVEL 1 - FLOOR PLAN
N
1 1/4" = 1'-0"
BLDG 15 LEVEL 1 - DEMO
204185
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS CHANNEL RACK, 7'H x 19"W x 29"D, SERVER CABINET IN MCR.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FACTORY TERMINATED IN MCR, FIELD TERMINATED
WITH LC TYPE CONNECTORS ON BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FACTORY TERMINATED IN MCR, FIELD TERMINATED
WITH LC TYPE CONNECTORS ON ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
CONDUIT PATHWAY 'B' TO BUILDING 38 TR ON GROUND FLOOR.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DO NOT DEMO WALL MOUNTED EQUIPMENT.
DATA
CENTER
DATA
CENTER
M D
A-B M
D A-A
M D
A-A M
D A-B
H D
A-B
SC
H D
A-A
SC
SC
SC
SC
SC
H
D A-
A
SC
H D
A- B
SC
SC
SC
SC
SC
4'
4'
6'
6'-51 8"
8'-2 3 16"
CRAC
CRAC
OFFICE
STAFF
29'-71 2"
31'-41 8"
FR
ON
T
FR
ON
T
FR
ON
T
FR
ON
TFR
ON
T
FR
ON
T
8'-115 16"
IRM
AMERICAN
LEGION
VFW
TR
AMERICAN
LEGION
VFW
DATA
CENTER
M D
A-B M
D A-A
M D
A-A M
D A-B
H D
A-B
SC
H D
A-A
SC
SC
SC
SC
SC
H
D A-
A
SC
H D
A- B
SC
SC
SC
SC
SC
CRAC
CRAC
OFFICE
STAFF
FR
ON
T
FR
ON
T
FR
ON
T
FR
ON
TFR
ON
T
FR
ON
T
HD
A
CA
BL
E 'A
HD
A
CA
BL
E
'B
HD
A
CA
BL
E 'A
HD
A
CA
BL
E
'B
DATA
CENTER
M D
A-B M
D A-A
M D
A-A M
D A-B
H D
A-B
SC
H D
A-A
SC
SC
SC
SC
SC
H
D A-
A
SC
H D
A- B
SC
SC
SC
SC
SC
CRAC
CRAC
OFFICE
STAFF
FR
ON
T
FR
ON
T
FR
ON
T
FR
ON
TFR
ON
T
FR
ON
T
FULL MESH CONNECTION IS REQUIRED
FROM THE HDA TO BOTH MDAs
FULL MESH CONNECTION IS REQUIRED
FROM THE HDA TO BOTH MDAs th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 37
NR 187 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-302
SPUR #: 2114
N
1 1/4" = 1'-0"
BLDG 37 LEVEL 1 -SR-DC-MCR - DEMO
N
2 1/4" = 1'-0"
BLDG 37 LEVEL 1 -SR-DC-MCR - FLOOR PLAN
N
5 1/4" = 1'-0"
BLDG 37 LEVEL 1 - TR - DEMO
N
6 1/4" = 1'-0"
BLDG 37 LEVEL 1 - TR - FLOOR PLAN
FINAL BID DOCUMENTS
N
3 1/8" = 1'-0"
BLDG 37 LEVEL 1 - SR-DC-MCR - HDA INTERCONNECT
N
4 1/8" = 1'-0"
BLDG 37 LEVEL 1 - SR-DC-MCR - MDA CROSS CONNECTION
THIS SHEET TO BE PRINTED IN COLOR
204186
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
TELECOMMUNICATIONS WALL-MOUNT RACK, 36"H x 26"W x 30"D, VENTED, SOLID WALL TYPE. TO BE
CAGED PER PHYSICAL SECURITY REQUIREMENTS.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
FIBER OPTIC
TELEPHONE
6A
CLEAN LINEN/
STORAGE
SEISMIC TOWER
FIBER OPTIC
TELEPHONE
6A
CLEAN LINEN/
STORAGE
TR
6B
6A
DATA ROOM
123B
TEAM OFFICE
123C
DATA ROOM
123B
TEAM OFFICE
TR
123C th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 38
NR 188 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-303
SPUR #: 2114
N
1 1/4" = 1'-0"
BLDG 38 LEVEL G - DEMO
N
2 1/4" = 1'-0"
BLDG 38 LEVEL G - FLOOR PLAN
N
3 BLDG 38 LEVEL 1 - DEMO
1/4" = 1'-0"
N
4 BLDG 38 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
204187
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
INSTALL 6RU NETWORK ENCLOSURE ABOVE EXISTING SERVER RACKS IN BIOMED, BLDG 38 225.
COORDINATE WITH BIOMED STAFF FOR CUT-OVER.
DEMO OLD FIBER OPTIC CABLING AFTER CUT-OVER.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
ELEV
TELE./ DATA
WHEELCHAIR
ALCOVE
C3
TELE./ DATA
ELEV
TR
237A
237A
LOGISTICS
PHARMACY
FEMALE
LOCKERS
IRM
312A
IRM
312A
FEMALE
LOCKERS
PHARMACY
LOGISTICS
TR
312B
2B
TR
4XX
BIO-MED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 38
NR 189 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-304
SPUR #: 2114
N
1 BLDG 38 LEVEL 2 - DEMO
1/4" = 1'-0"
N
2 BLDG 38 LEVEL 2 - FLOOR PLAN
1/4" = 1'-0"
N
4 BLDG 38 LEVEL 3 - DEMO
1/4" = 1'-0"
N
5 BLDG 38 LEVEL 3 - FLOOR PLAN
1/4" = 1'-0"
N
6 BLDG 38 LEVEL 4 - FLOOR PLAN
1/4" = 1'-0"
N
3 BLDG 38 LEVEL 2 BIOMED 225 - FLOOR PLAN
1/4" = 1'-0"
204188
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
INSTALL 6RU NETWORK ENCLOSURE ABOVE EXISTING SERVER RACKS IN BIOMED, BLDG 42 BC122.
COORDINATE WITH BIOMED STAFF FOR CUT-OVER.
DEMO OLD FIBER OPTIC CABLING AFTER CUT-OVER.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
VENDING
CB52
TR
CB52A
CB52A
CB52
VENDING
CB52
IRM
BC117
IRM
BC117
BC
TELEPHONE
BB137TELEPHONE
BB137
BB
ELECTRICAL
BD104
ELECTRICAL
BD104
BD
COMMUNICATIONS
CLOSET
CB13A-42
ELECTRICAL
CB13B-42
COMMUNICATIONS
CLOSET
CB13A-42
ELECTRICAL
CB13B-42
CB
B-
CB13A-42
COMPUTER
BC122
EXISTING BOIMED
SERVER RACKS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 42
NR 190 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-305
SPUR #: 2114
N
4 BLDG 42 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
3 BLDG 42 LEVEL 1 - DEMO
1/4" = 1'-0"
N
1 BLDG 42 LEVEL 1 - DEMO
1/4" = 1'-0"
N
2 BLDG 42 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
5 BLDG 42 LEVEL 1 - DEMO
1/4" = 1'-0"
N
6 BLDG 42 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
7 BLDG 42 LEVEL 1 - DEMO
1/4" = 1'-0"
N
8 BLDG 42 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
9 BLDG 42 LEVEL 1 - DEMO
1/4" = 1'-0"
N
10 BLDG 42 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
11 BLDG 42 BIOMED RM 122 - FLOOR PLAN
1/4" = 1'-0"
204189
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
TELECOMMUNICATIONS WALL-MOUNT RACK, 36"H x 26"W x 30"D, VENTED, SOLID WALL TYPE. TO BE
CAGED PER PHYSICAL SECURITY REQUIREMENTS.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
N.E. ELEC.
TELE.
STORAGE
123A
N.E. ELEC.
TR
OFFICE
136DATA
OFFICE
TR
OFFICE
OFFICE
SAFETY
EQUIPMENT
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 43, 81
NR 191 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-306
43, 81
SPUR #: 2114
N
1 BLDG 43 LEVEL 1 - DEMO
1/4" = 1'-0"
N
2 BLDG 43 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
3 BLDG 81 LEVEL 1 - DEMO
1/4" = 1'-0"
N
4 BLDG 81 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
5 BLDG 44 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
204190
DURING INSTALLATION..
2. ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF
ADDITIONAL CABLE DROPS.
3. ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL
CUT-OVER TO THE NEW CABLING.
4. EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN ITS
DESIGNATED TR.
5. EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
6. EXISTING CAT6A CABLING MAY REMAIN IN PLACE.
7. LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED
UTILIZING AN OLTS AND AN OTDR PER THE TIER 2 STANDARD.
8. PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE MANAGERS AS APPLICABLE. ADHERE TO CABLING COLOR CODE AND LABELING
STANDARDS. (SEE SPECIFICATIONS)
9. NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS
ALONG THE CABLE PATHWAYS.
10. EXISTING CONDUITS TO REMAIN.
11. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
12. ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE SECONDARY BONDING BUSBAR.BOND ALL PARTS OF TRAY SYSTEMS TO THE TELECOMMUNICATIONS PRIMARY/SECONDARY
BUSBAR.
13. AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE
WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR
SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER
ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE
RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES WHERE CABLING
WAS REMOVED.
14. AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE
SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE
THAT ANY CABLING IN THE CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR BIOMED ARE NOT DISTURBED (TYPICALLY
ORANGE CATEGORY AND AQUA OM4 FIBER OPTIC CABLING).
ENSURE ALL CATEGORY AND FIBER OPTIC CABLING FOR WIRELESS AND SECURITY SYSTEMS ARE NOT
DISTURBED.
15. ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND
CABLE TRAYS (IF POSSIBLE) IN GENERAL PATHWAYS.
16. CONTRACTOR SHALL REINSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT.
17. CONTRACTOR SHALL INSTALL TEMPORARY FIRESTOPPING IN ANY PENETRATIONS OF NETWORK
CABLING THROUGH FIRE RATED WALLS AT THE END OF EVERY WORK SHIFT. TEMPORARY
FIRESTOPPING SHALL CONSIST OF MINERAL WOOL AND PROVIDE PROTECTION AGAINST FIRE/SMOKE
SPREAD THROUGH UNSEALED PENETRATION.
18. CONTRACTOR SHALL INSTALL FIRESTOPPING IN ALL FIRE RATED WALLS WHERE NETWORK CABLING
WAS REMOVED TO ENSURE FIRE RATING OF WALL.
TECHNOLOGY KEYNOTES
TELECOMMUNICATIONS EQUIPMENT RACK, 7'H x 19"W x 29"D, 4-POST, OPEN FRAME TYPE.
VERTICAL CABLE MANAGER, 6"Wx 6"D, W/DOOR
WIRE-MESH (WIRE BASKET) CABLE TRAY - 12"W x 4"H (TYPICAL)
INBOUND REDUNDANT FIBER BACKBONE 'A' CABLES FROM MDA-A IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLE FIELD TERMINATED WITH LC TYPE CONNECTORS ON
BOTH ENDS.
INBOUND REDUNDANT FIBER BACKBONE 'B' CABLES FROM MDA-B IN SR/DC/MCR. INCLUDES (1) 24 STRAND SINGLEMODE (OS2) FIBER OPTIC CABLES FIELD TERMINATED WITH LC TYPE CONNECTORS
ON BOTH ENDS.
INSTALL (2) 4"SLEEVES EXITING THE TRs FOR UTP CAT6 CABLING TO WAOs.
REUSE VERTICAL SLEEVES OR CONDUITS IN EXISTING TRs.
TELECOMMUNICATIONS WALL-MOUNT RACK, 36"H x 26"W x 30"D, VENTED, SOLID WALL TYPE. TO BE
CAGED PER PHYSICAL SECURITY REQUIREMENTS.
DEMO DATA CABLING AFTER CUT-OVER. DO NOT DEMO CABLING FOR SYSTEMS RELATED TO BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
DEMO NETWORK RACK AFTER CUT-OVER. DO NOT DEMO ENCLOSURES OR DEVICES RELATED TO
BIOMED, WIRELESS, SECURITY & CAMERA SYSTEMS.
TR
OFFICE
OFFICE
126 DATA
COMM
TR
DATA
TR
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
EHRM INFRASTRUCTURE
UPGRADES
No. REVISION DESCRIPTION DATE
CIVIL/ STRUCTURAL ENGINEER
OATES ASSOCIATES
100 LANTER COURT, SUITE 1
COLLINSVILLE, IL 62234
(618) 345-2200
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
DATA/COMM CONSULTANT
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
COMMISSIONING AGENT
ES2
13401 N. SANTA FE AVE.
OKLAHOMA, OK 73114
(405) 528-4500
SETH ANDREW CAVIN - ARCHITECT #AR12100034 EXP. 11/30/2024
JAMES ROSS MYLES - PROFESSIONAL ENGINEER #062.071715 EXP. 11/30/2023
/1
5/
:5 8:
P
M
TECHNOLOGY ENLARGED PLANS - 82, 83
NR 192 205SR04/20/2023
657A5-21-700
MARION VA MEDICAL CENTER
2401 WEST MAIN ST.
MARION, IL 62959 T-307
82, 83
SPUR #: 2114
N
1 BLDG 82 LEVEL 1 - DEMO
1/4" = 1'-0"
N
2 BLDG 82 LEVEL 1 - FLOOR PLAN
1/4" = 1'-0"
N
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .