This addendum modifies construction drawings and specifications for an infrastructure upgrades project at a Veterans Affairs medical center in Marion, Illinois. It adds specification sections for cast-in-place concrete and unit masonry work. Drawing revisions include replacing sheets to modify partition details, relocate a nurse's station, and add dimensions for rooftop equipment. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas seeking construction services for the infrastructure upgrades project at the Marion VAMC described in the addendum.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM
PROJECT NUMBER 657A5-21-700 (SPUR 2114)
PROJECT NAME EHRM Infrastructure
Upgrades – Marion, IL
ADDENDUM NUMBER 03
DATE August 23, 2023 SUBJECT RFI Responses
A | 312 SW 25th St. Oklahoma City, OK 73109 P | 405.842.6100 E | howdy@spur-design.com W | spur-design.com
THE FOLLOWING MODIFICATIONS, ADDITIONS, AND DELETIONS ARE HEREBY MADE A PART OF THE CONTRACT DOCUMENTS.
SEALS:
GENERAL: This Addendum adds specification sections 03 30 00 Cast-In-Place Concrete, 04 20 00 Unit Masonry, and revisions to the Partition Types and Window Cover Detail on sheet AE/601, and Keynote changes on.
PROJECT MANUAL:
GENERAL
1. 03 30 00 Cast-In-Place Concrete - 8 1/2 x 11
Item 1: Add specification section.
2. 04 20 00 Unit Masonry - 8 1/2 x 11
Item 1: Add specification section.
DRAWINGS:
ARCHITECTURAL
3. AE408 ENLARGED PLANS - BLDG 42 43 81 – 30 x 42
Item 1: Remove sheet in its entirety and replace with revised sheet.
Item 2: KEYNOTE LEGEND: Keynote 9.86 changed to “Relocate Nurse Station. Provide new base and trim as required”.
4. AE601 DOOR SCHEDULE AND PARTITION TYPES – 30 x 42
Item 1: Remove sheet in its entirety and replace with revised sheet.
Item 2: 3/AE601 PARTITION TYPES: Partition types modified to change metal stud U-Track at the underside of the deck to a slip track. This partition type occurs at Telecom Room 237A.
A | 312 SW 25th St. Oklahoma City, OK 73109 P | 405.842.6100 E | howdy@spur-design.com W | spur-design.com
Item 3: 7/AE601 WINDOW COVER DETAIL: Detail modified to remove steel angles.
5. M-105 REFERENCE PLANS – BUILDINGS 81 & 82 – 30 x 42
Item 1: Remove sheet in its entirety and replace with revised sheet.
Item 2: 4/M-105 BUILDING 82 REFERENCE PLANS: Dimensions added for rooftop equipment.
TOTAL: 43 Pages 8 1/2 x 11
3 Sheets 30 x 42
END OF ADDENDUM NO. 3