Civil Drawings CU217-CU300.pdf

PDF 16 MB Posted

Attached to
36C77623B0047 - Y1DA--657A5-21-700 EHRM Infrastructure Upgrades Construction Marion, IL VAMC
Solicitation number
36C77623B0047_1
Issued by

About this file

This document provides details on a federal contract opportunity for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals for infrastructure upgrades at the Marion, Illinois VA Medical Center under solicitation number 36C77623B0047. The scope of work involves construction services to upgrade the facility's EHRM systems. Proposals are due by January 15, 2022, and the period of performance is one year from date of award. The anticipated award date is March 1, 2022. Pricing shall be fixed price, and the contract has no set-aside provisions. The 16MB PDF file contains civil drawings for the project areas between buildings CU217 through CU300.

View the file

Other files

File Type Posted
Wage Determination - Williamson County - 9.8.23.pdf PDF
36C77623B0047 0009.docx DOCX document
36C77623B0047 Amendment 0008.docx DOCX document
ae601 door schedule and partition types.pdf PDF
3837_001.pdf PDF
M-105 REFERENCE PLANS - BUILDINGS 81 and 82.pdf PDF
04 20 00 UnitMasonry.pdf PDF
657a5-21-700 ehrm marion il addendum-03.pdf PDF
03 30 00 Cast-in-Place Concrete.pdf PDF
36C77623B0047 Amendment 0007.docx DOCX document
ae408 enlarged plans - bldg 42 43 81.pdf PDF
1 Technical Questions Tracking Spreadsheet - Marion Infra Constr - 8-24-23 Final.pdf PDF
Wage rates - Williamson - 8.14.23.pdf PDF
B 38 Drawing Package_Part5.pdf PDF
Building 14 Boiler Plant Geotechnical Report.pdf PDF
B 38 Drawing Package_Part4.pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (1).pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (5).pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (3).pdf PDF
2017-0502.10 Building 13 Geotech Report.pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (2).pdf PDF
36C77623B0047 Amendment 0006.docx DOCX document
B 38 Drawing Package_Part3.pdf PDF
15225023 VA Project 657A5-21-700 EHRM Marion Geotechnical Report.pdf PDF
B 38 Drawing Package_Part1.pdf PDF
B 38 Drawing Package_Part6.pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (4).pdf PDF
B 38 Drawing Package_Part2.pdf PDF
Wage Determination - Williamson 8.4.pdf PDF
36C77623B0047 0005.pdf PDF
Attachment 1 - Missing Specs.zip ZIP file
36C77623B0047 0004.pdf PDF
36C77623B0047 0003.pdf PDF
Construction Wage Rates - Williamson County - 7-28-23.pdf PDF
Site Visit Sign-In Sheet - Marion Infra 7-31-23.pdf PDF
Attachment 1 - Electrical Plans 657A5-21-700.zip ZIP file
36C77623B0047 Amendment 0002.pdf PDF
Attachment 1 - 36C77623B0047_1.pdf PDF
36C77623B0047 Amendment 0001.docx DOCX document
ARCHITECTURAL.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
STRUCTURAL.pdf PDF
Civil Drawings CU301-CIVIL DETAILS.pdf PDF
HAZARDOUS MATERIALS.pdf PDF
Civil Drawings CU211-CU213.pdf PDF
36C77623B0047_1.docx DOCX document
Civil Drawings CU207-CU210.pdf PDF
GENERAL.pdf PDF
Civil Drawings CU-214-CU216.pdf PDF
Brand Name Justification - Marion EHRM Infra Redacted.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TE

LE

CO

M

EL

EC

TR

IC

WATER

TELECOM

+5

+0

35+82

36+00

GAS

TELECOM

WATERELECTRIC

ELECTRIC

WATER

EL

EC

TR

IC

EL

EC

TR

IC

11+00

11+61

40+00

41+00 41+19 43 +0

+4

10+00 10+22

11+60

10+00

11+00

9+60 10+00 11+00 12+00 12+20

2.0

1.8

0.7

0.2

9.9

9.5

0.6

10+60 11+00 12+00

1.3

1.6

1.2

1.5 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

A

B

C

D

E

F

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SETH ANDREW CAVIN - ARCHITECT

JAMES ROSS MYLES - MECHANICAL ENGINEER

BENJAMIN ELIAS NOE - ELECTRICAL ENGINEER

#011.023503 EXP. 11/30/2022

#062.071715 EXP. 11/30/2023

#062.072296 EXP. 11/30/2023

CIVIL/ STRUCTURAL ENGINEER

OATES ASSOCIATES

100 LANTER COURT, SUITE 1

COLLINSVILLE, IL 62234

(618) 345-2200

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

DATA/COMM CONSULTANT

ASPEN ENGINEERING & CONSTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 86301

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

EHRM INFRASTRUCTURE

UPGRADES

COMMISSIONING AGENT

ES2

13401 N. SANTA FE AVE.

OKLAHOMA, OK 73114

(405) 528-4500

A

M

AM

PHJ

FINAL BID DOCUMENTS

04/20/2023

657A5-21-700

MARION VA MEDICAL CENTER

2401 WEST MAIN ST.

MARION, IL 62959

SPUR #: 2114

No. REVISION DESCRIPTION DATE

CONTROLLED UNCLASSIFIED INFORMATION - CUI

CONTROLLED UNCLASSIFIED INFORMATION - CUI

N

SCALE: 1" = 20'

BUILDING 81

BUILDING 82

BUILDING 8

FIBER PLAN & PROFILE

CU217

PATH A.14

SEE SHEET CU 216

ELECTRICAL ROUTE 1

SEE SHEET CU 300

PATH A.13

NEW FIBER DUCTBANK

PATH B.13

REMOVE AND REPLACE EXISTING CONCRETE

SIDEWALK, CURB & GUTTER, ASPHALT PAVEMENT (TYP.),

SEE DETAIL 1 ON SHEET CU200, 8 & 11 ON SHEET CU401

PATH B.13

NEW FIBER DUCTBANK

MH EXAM

ROOM 116

EXAM

ROOM 137

REMOVE AND REPLACE EXISTING CONCRETE

SIDEWALK (TYP.),

SEE DETAIL 1 ON SHEET CU400

PATH A.12

SEE SHEET CU 216

STA. 10+50 TO 10+87

REMOVE AND REPLACE EXISTING CONCRETE

SIDEWALK, CURB & GUTTER, AND ASPHALT PAVEMENT,

SEE DETAIL 1 ON SHEET CU400, 8 & 11 ON SHEET CU401

BLDG 82

BLDG 81

EXISTING GROUND

ELECTRIC, ESTIMATED 4 FT DEEP

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

STA. 11+38 TO 11+44

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK

SEE DETAIL 1 ON SHEET CU400

STORM SEWER 24" HDPE, APPROX. INV 452.57,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

STORM, UNKNOWN DEPTH

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

ELECTRIC, UNKNOWN DEPTH,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

ELECTRICAL ROUTE 2

SEE SHEET CU 300

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK (TYP.),

SEE DETAIL 1 ON SHEET CU400

OFFICE

ROOM 014

PATH A.13

STA. 11+43 TO 11+50

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK

SEE DETAIL 1 ON SHEET CU400

ELECTRIC, ESTIMATED 3 FT DEEP,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

FIBER OPTIC, UNKNOWN DEPTH

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

BLDG 82BLDG 8

EXISTING

GROUND

NEW ELECTRICAL ROUTE 2 DUCTBANK,

PROVIDE 12" VERTICAL SEPARATION

STA. 10+48

COMM. MANHOLE

4' X 4'

TOP: 461.75

110' DUCT 4-4" CONDUIT50' DUCT 4-4" CONDUIT

61' DUCT 4-4" CONDUIT

6' RADIUS (TYP)

6' RADIUS (TYP)

6' RADIUS (TYP)

NOTE:

1. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE

BEEN PLOTTED FROM AVAILABLE SURVEYS AND RECORDS. THEIR

LOCATIONS MUST BE CONSIDERED TO BE APPROXIMATE ONLY. IT IS

POSSIBLE THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS

NOT PRESENTLY KNOWN OR SHOWN. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO DETERMINE THEIR EXISTENCE AND EXACT

LOCATION AND TO AVOID DAMAGE THERETO, WHICH SHALL

INCLUDE ADJUSTMENTS OR RELOCATIONS AS NECESSARY TO

COMPLETE THE WORK SHOWN.

2. ALL OPEN TRENCHES MUST HAVE A 48-INCH TALL, ORANGE MESH

FENCE SURROUNDING THE AREA.

3. INSTALL TOP OF DUCT BANK AT LEAST 24 INCHES BELOW FINISHED

GRADE IN AREAS NOT SUBJECT TO DELIBERATE TRAFFIC, AND AT

LEAST 30 INCHES BELOW FINISHED GRADE IN DELIBERATE TRAFFIC

PATHS FOR VEHICLES.

4. CONTRACTOR SHALL REFER TO THE TECHNOLOGY PLANS TO

ENSURE CONDUIT FROM DUCTBANKS ENTER EACH BUILDING AT

THE INTENDED ROOM AND LOCATION. ADJUST DUCTBANK

ALIGNMENT IF NEEDED.

KEYED NOTES

1 CONTRACTOR TO INSTALL CONDUIT INTO BUILDING IN ACCORDANCE TO

THE VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL,

(PSRDM), LATEST EDITION.

MH

MH

PROVIDE AND INSTALL 4" SCH. 80 CONCRETE ENCASED DUCT BANK

ENCLOSURE. CONTRACTOR TO PROVIDE PULL-STRING

THROUGHOUT ENTIRE LENGTH OF CONDUITS.

TR 135

ELEV. 457.29

204055

ELECTRIC

ELECTRIC

W

ATER

ELECTRIC

ELECTRIC

TELECOM

STORM

ABANDONED

37+

38+00 39+00 40+00 41+00

+0

+0

+7

36+60 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00

2.1

2.0

1.4

0.8

0.7

0.5

0.4

9.7

9.2

8.7

8.1

7.8

7.6

7.3

7.0

6.9

6.9

6.7

5.9

5.8

5.8

6.1

4.0

3.5

3.0

2.5 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

A

B

C

D

E

F

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SETH ANDREW CAVIN - ARCHITECT

JAMES ROSS MYLES - MECHANICAL ENGINEER

BENJAMIN ELIAS NOE - ELECTRICAL ENGINEER

#011.023503 EXP. 11/30/2022

#062.071715 EXP. 11/30/2023

#062.072296 EXP. 11/30/2023

CIVIL/ STRUCTURAL ENGINEER

OATES ASSOCIATES

100 LANTER COURT, SUITE 1

COLLINSVILLE, IL 62234

(618) 345-2200

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

DATA/COMM CONSULTANT

ASPEN ENGINEERING & CONSTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 86301

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

EHRM INFRASTRUCTURE

UPGRADES

COMMISSIONING AGENT

ES2

13401 N. SANTA FE AVE.

OKLAHOMA, OK 73114

(405) 528-4500

A

M

AM

PHJ

FINAL BID DOCUMENTS

04/20/2023

657A5-21-700

MARION VA MEDICAL CENTER

2401 WEST MAIN ST.

MARION, IL 62959

SPUR #: 2114

No. REVISION DESCRIPTION DATE

CONTROLLED UNCLASSIFIED INFORMATION - CUI

CONTROLLED UNCLASSIFIED INFORMATION - CUI

N

SCALE: 1" = 20'

FIBER PLAN & PROFILE

CU218

PATH A.15

NEW FIBER DUCTBANK

PATH A.15

STA 41+14 TO 41+22

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1

ON SHEET CU400

STA 37+64 TO 38+28

REMOVE AND REPLACE EXISTING

CONCRETE PAVEMENT AND CURB &

GUTTER, SEE DETAILS

8, 9, & 10 ON SHEET CU401

STA 40+75 TO 41+11

REMOVE AND REPLACE EXISTING

CONCRETE PAVEMENT AND CURB &

GUTTER, SEE DETAILS

8, 9, AND 10 ON SHEET CU401

STA 41+63 TO 41+69

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1 ON SHEET CU400

STA 43+25 TO 43+32

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1 ON SHEET CU400

WATER ESTIMATED 4 FT DEEP,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

EXISTING GROUND

BLDG 83

BLDG 1

REMOVE AND REPLACE EXISTING

CONCRETE PAVEMENT AND CURB

& GUTTER (TYP.), SEE DETAILS

8, 9, & 10 ON SHEET CU401

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK (TYP.),

SEE DETAIL 1 ON SHEET CU400

NO

RT

H

PE

RI

PH

ER

Y

RO

AD

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1 ON SHEET CU400

REMOVE AND REPLACE EXISTING

CONCRETE PAVEMENT AND CURB &

GUTTER, SEE DETAILS

8, 9, & 10 ON SHEET CU401

RECEPTION

ROOM 112

TREATMENT

ROOM 009

ELECTRIC ESTIMATED 3 FT DEEP,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

ELECTRIC ESTIMATED 2 FT DEEP,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

BUILDING 1

STA 42+01 TO 43+26

REMOVE AND REPLACE EXISTING

CONCRETE PAVEMENT AND CURB &

GUTTER, SEE DETAILS

8, 9, AND 10 ON SHEET CU401

ELECTRIC ESTIMATED 3 FT DEEP,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

STA 37+58 TO 37+64

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1

ON SHEET CU400

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK (TYP.),

SEE DETAIL 1 ON SHEET CU400

REMOVE AND REPLACE EXISTING CONCRETE

SIDEWALK, CURB & GUTTER, ASPHALT PAVEMENT (TYP.),

SEE DETAIL 1 ON SHEET CU200, 8 & 11 ON SHEET CU401

623' DUCT 6-4" CONDUIT

53' DUCT 6-4"

CONDUIT

STA. 37+53

COMM. MANHOLE

4' X 4'

TOP: 471.90

RADIUS 6' (MIN)

NOTE:

1. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE BEEN

PLOTTED FROM AVAILABLE SURVEYS AND RECORDS. THEIR LOCATIONS

MUST BE CONSIDERED TO BE APPROXIMATE ONLY. IT IS POSSIBLE THERE

MAY BE OTHERS, THE EXISTENCE OF WHICH IS NOT PRESENTLY KNOWN OR

SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR

EXISTENCE AND EXACT LOCATION AND TO AVOID DAMAGE THERETO, WHICH

SHALL INCLUDE ADJUSTMENTS OR RELOCATIONS AS NECESSARY TO

COMPLETE THE WORK SHOWN.

2. ALL OPEN TRENCHES MUST HAVE A 48-INCH TALL, ORANGE MESH FENCE

SURROUNDING THE AREA.

3. INSTALL TOP OF DUCT BANK AT LEAST 24 INCHES BELOW FINISHED GRADE IN

AREAS NOT SUBJECT TO DELIBERATE TRAFFIC, AND AT LEAST 30 INCHES

BELOW FINISHED GRADE IN DELIBERATE TRAFFIC PATHS FOR VEHICLES.

4. CONTRACTOR SHALL REFER TO THE TECHNOLOGY PLANS TO ENSURE

CONDUIT FROM DUCTBANKS ENTER EACH BUILDING AT THE INTENDED ROOM

AND LOCATION. ADJUST DUCTBANK ALIGNMENT IF NEEDED.

STA. 41+53

COMM. MANHOLE

4' X 4'

TOP: 466.02

KEYED NOTES

1 CONTRACTOR TO INSTALL CONDUIT INTO BUILDING IN ACCORDANCE TO

THE VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL,

(PSRDM), LATEST EDITION.

MH

MH

MH

MH

PROVIDE AND INSTALL 4" SCH. 80 CONCRETE ENCASED DUCT BANK

ENCLOSURE. CONTRACTOR TO PROVIDE PULL-STRING

THROUGHOUT ENTIRE LENGTH OF CONDUITS.

BUILDING 83

BUILDING 42

ELEV. 466.85

ELEV. 465.14

ELEV. 459.95

204056

WATER

TELECOM

ELECTRIC

W

ATER

ELECTRIC

ELECTRIC

+8

+8

36+00

FIBER OPTIC

GAS

TELECOM

WATER

ELECTRIC

ELECTRIC

+0

+6

+0

+0

+1

43+00 43+44

+2

21+66

+0

11+60

10+00

11+00

39+60 40+00 41+00 41+60

1.2

1.5

1.3

1.1

1.4

42+40 43+00 44+00

2.2

1.5

2.3 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

A

B

C

D

E

F

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SETH ANDREW CAVIN - ARCHITECT

JAMES ROSS MYLES - MECHANICAL ENGINEER

BENJAMIN ELIAS NOE - ELECTRICAL ENGINEER

#011.023503 EXP. 11/30/2022

#062.071715 EXP. 11/30/2023

#062.072296 EXP. 11/30/2023

CIVIL/ STRUCTURAL ENGINEER

OATES ASSOCIATES

100 LANTER COURT, SUITE 1

COLLINSVILLE, IL 62234

(618) 345-2200

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

DATA/COMM CONSULTANT

ASPEN ENGINEERING & CONSTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 86301

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

EHRM INFRASTRUCTURE

UPGRADES

COMMISSIONING AGENT

ES2

13401 N. SANTA FE AVE.

OKLAHOMA, OK 73114

(405) 528-4500

A

M

AM

PHJ

FINAL BID DOCUMENTS

04/20/2023

657A5-21-700

MARION VA MEDICAL CENTER

2401 WEST MAIN ST.

MARION, IL 62959

SPUR #: 2114

No. REVISION DESCRIPTION DATE

CONTROLLED UNCLASSIFIED INFORMATION - CUI

CONTROLLED UNCLASSIFIED INFORMATION - CUI

N

SCALE: 1" = 20'

BUILDING 81

BUILDING 82

BUILDING 8

ELECTRICAL PLAN & PROFILE

CU300

PATH B.11

SEE SHEET CU 215

ELECTRIC ROUTE 2

NEW ELECTRIC DUCTBANK

ELECTRIC ROUTE 1

NEW ELECTRIC DUCTBANK

ELECTRICAL ROUTE 2ELECTRICAL ROUTE 1

STA. 40+53 TO 41+19

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK, CURB & GUTTER, AND ASPHALT PAVEMENT,

SEE DETAIL 1 ON SHEET CU400, 8 & 11 ON SHEET CU401

BLDG 81BLDG 8 EXISTING GROUND

GAS, WATER AND FIBER OPTIC, UNKNOWN DEPTH (TYP.)

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

STA. 43+00 TO 43+44

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK, CURB & GUTTER, AND ASPHALT PAVEMENT,

SEE DETAIL 1 ON SHEET CU400, 8 AND 11 ON SHEET CU401

BLDG 81BLDG 82 EXISTING

GROUND

WATER, ESTIMATED 5 FT DEEP

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

REMOVE AND REPLACE EXISTING ASPHALT PAVEMENT (TYP.),

SEE DETAIL 1 ON SHEET CU400, 8 AND 11 ON SHEET CU401

REMOVE AND REPLACE EXISTING CONCRETE

SIDEWALK, CURB & GUTTER, ASPHALT PAVEMENT (TYP.),

SEE DETAIL 1 ON SHEET CU400, 8 & 11 ON SHEET CU401

ELECTRIC, ESTIMATED 3 FT DEEP

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

ELECTRIC, ESTIMATED 4 FT DEEP

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

PATH B.13

SEE SHEET CU 217

PATH B.10

SEE SHEET CU 214

STORM SEWER, UNKNOWN DEPTH

OFFICE 8

ROOM 144

MECH

ROOM 134

PATH A.13

SEE SHEET CU217

PATH B.12

SEE SHEET CU 215

STA. 11+36

ELEC. MANHOLE 4' X 4'

TOP: 461.21

INV: 457.28 (S)

INV: 455.00 (W)

SEE ELECTRICAL PLANS FOR

DISCONNECT LOCATION

SEE ELECTRICAL PLANS FOR

DISCONNECT LOCATION

SEE ELECTRICAL PLANS FOR

DISCONNECT LOCATION

SEE ELECTRICAL PLANS FOR

DISCONNECT LOCATION

44' DUCT 1-2"

CONDUIT 33' DUCT 1-2"

CONDUIT84' DUCT 1-2" CONDUIT

OFFICE

ROOM 014

MIN 4'R (TYP)

NOTE:

1. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE

BEEN PLOTTED FROM AVAILABLE SURVEYS AND RECORDS. THEIR

LOCATIONS MUST BE CONSIDERED TO BE APPROXIMATE ONLY. IT

IS POSSIBLE THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS

NOT PRESENTLY KNOWN OR SHOWN. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO DETERMINE THEIR EXISTENCE AND EXACT

LOCATION AND TO AVOID DAMAGE THERETO, WHICH SHALL

INCLUDE ADJUSTMENTS OR RELOCATIONS AS NECESSARY TO

COMPLETE THE WORK SHOWN.

2. ALL OPEN TRENCHES MUST HAVE A 48-INCH TALL, ORANGE MESH

FENCE SURROUNDING THE AREA.

3. INSTALL TOP OF DUCT BANK AT LEAST 24 INCHES BELOW FINISHED

GRADE IN AREAS NOT SUBJECT TO DELIBERATE TRAFFIC, AND AT

LEAST 30 INCHES BELOW FINISHED GRADE IN DELIBERATE

TRAFFIC PATHS FOR VEHICLES.

MH

MH

KEYED NOTES

1 PROVIDE AND INSTALL 4-CELL 2" SCH. 80 CONCRETE

ENCASED DUCT BANK ENCLOSURE.

CONTRACTOR TO PROVIDE PULL-STRING

THROUGHOUT ENTIRE LENGTH OF CONDUITS.

204057

055_CU217 - FIBER PLAN & PROFILE
056_CU218 - FIBER PLAN & PROFILE
057_CU300 - ELECTRICAL PLAN & PROFILE

File details come from the government source that posted it. Updated .