Civil Drawings CU211-CU213.pdf

PDF 14 MB Posted

Attached to
36C77623B0047 - Y1DA--657A5-21-700 EHRM Infrastructure Upgrades Construction Marion, IL VAMC
Solicitation number
36C77623B0047_1
Issued by

About this file

This document provides details on a federal contract opportunity for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals for infrastructure upgrades at the Marion, Illinois Veterans Affairs Medical Center under solicitation number 36C77623B0047. The contract will support renovations and improvements to the facility's EHRM systems. Offerors should submit proposals by the listed response date to be considered for this construction project, which aims to modernize critical infrastructure supporting healthcare operations at the medical center. Relevant details include the contracting agency, location of work, response deadline, and focus on EHRM infrastructure upgrades.

View the file

Other files

File Type Posted
Wage Determination - Williamson County - 9.8.23.pdf PDF
36C77623B0047 0009.docx DOCX document
36C77623B0047 Amendment 0008.docx DOCX document
ae601 door schedule and partition types.pdf PDF
3837_001.pdf PDF
M-105 REFERENCE PLANS - BUILDINGS 81 and 82.pdf PDF
04 20 00 UnitMasonry.pdf PDF
657a5-21-700 ehrm marion il addendum-03.pdf PDF
03 30 00 Cast-in-Place Concrete.pdf PDF
36C77623B0047 Amendment 0007.docx DOCX document
ae408 enlarged plans - bldg 42 43 81.pdf PDF
1 Technical Questions Tracking Spreadsheet - Marion Infra Constr - 8-24-23 Final.pdf PDF
Wage rates - Williamson - 8.14.23.pdf PDF
B 38 Drawing Package_Part5.pdf PDF
Building 14 Boiler Plant Geotechnical Report.pdf PDF
B 38 Drawing Package_Part4.pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (1).pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (5).pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (3).pdf PDF
2017-0502.10 Building 13 Geotech Report.pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (2).pdf PDF
36C77623B0047 Amendment 0006.docx DOCX document
B 38 Drawing Package_Part3.pdf PDF
15225023 VA Project 657A5-21-700 EHRM Marion Geotechnical Report.pdf PDF
B 38 Drawing Package_Part1.pdf PDF
B 38 Drawing Package_Part6.pdf PDF
2. B 37 Marion VA Field Print Model (2 of 2) (4).pdf PDF
B 38 Drawing Package_Part2.pdf PDF
Wage Determination - Williamson 8.4.pdf PDF
36C77623B0047 0005.pdf PDF
Attachment 1 - Missing Specs.zip ZIP file
36C77623B0047 0004.pdf PDF
36C77623B0047 0003.pdf PDF
Construction Wage Rates - Williamson County - 7-28-23.pdf PDF
Site Visit Sign-In Sheet - Marion Infra 7-31-23.pdf PDF
Attachment 1 - Electrical Plans 657A5-21-700.zip ZIP file
36C77623B0047 Amendment 0002.pdf PDF
Attachment 1 - 36C77623B0047_1.pdf PDF
36C77623B0047 Amendment 0001.docx DOCX document
ARCHITECTURAL.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
STRUCTURAL.pdf PDF
Civil Drawings CU301-CIVIL DETAILS.pdf PDF
HAZARDOUS MATERIALS.pdf PDF
36C77623B0047_1.docx DOCX document
Civil Drawings CU207-CU210.pdf PDF
GENERAL.pdf PDF
Civil Drawings CU217-CU300.pdf PDF
Civil Drawings CU-214-CU216.pdf PDF
Brand Name Justification - Marion EHRM Infra Redacted.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

28+66 28+00

25+5725+00

27+60 28+00 29+00

6.3

6.7

7.0

7.1 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

A

B

C

D

E

F

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SETH ANDREW CAVIN - ARCHITECT

JAMES ROSS MYLES - MECHANICAL ENGINEER

BENJAMIN ELIAS NOE - ELECTRICAL ENGINEER

#011.023503 EXP. 11/30/2022

#062.071715 EXP. 11/30/2023

#062.072296 EXP. 11/30/2023

CIVIL/ STRUCTURAL ENGINEER

OATES ASSOCIATES

100 LANTER COURT, SUITE 1

COLLINSVILLE, IL 62234

(618) 345-2200

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

DATA/COMM CONSULTANT

ASPEN ENGINEERING & CONSTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 86301

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

EHRM INFRASTRUCTURE

UPGRADES

COMMISSIONING AGENT

ES2

13401 N. SANTA FE AVE.

OKLAHOMA, OK 73114

(405) 528-4500

P

M

AM

PHJ

FINAL BID DOCUMENTS

04/20/2023

657A5-21-700

MARION VA MEDICAL CENTER

2401 WEST MAIN ST.

MARION, IL 62959

SPUR #: 2114

No. REVISION DESCRIPTION DATE

CONTROLLED UNCLASSIFIED INFORMATION - CUI

CONTROLLED UNCLASSIFIED INFORMATION - CUI

N

PATH B.9

NEW FIBER DUCTBANK

SCALE: 1" = 10'

MOD-3

BUILDING 43

FIBER PLAN & PROFILE

CU211

EXISTING

GROUND

BLDG 43

MOD-3

PATH B.9

REMOVE AND REPLACE EXISTING

ASPHALT ROADWAY AND CURB & GUTTER ,

SEE DETAILS 8 & 11 ON SHEET CU401

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1 ON SHEET CU400

STA 28+11 TO 28+35

REMOVE AND REPLACE EXISTING

ASPHALT ROADWAY, CURB & GUTTER, AND CONCRETE SIDEWALK,

SEE DETAIL 1 ON SHEET CU400 AND SEE DETAILS 8 & 11 ON SHEET CU401

WATER & ELECTRIC, UNKNOWN

DEPTH ADJUST DUCTBANK

ALIGNMENT IF IN CONFLICT

ELECTRIC, 4' DEEP,ADJUST DUCTBANK

ALIGNMENT IF IN CONFLICT

STAIRWELL

OPEN OFFICE

ROOM 100

NEW FIBER CONDUIT INSTALLED IN EXISTING STEAM TUNNEL.

SEE TELECOMMUNICATION DRAWINGS FOR ROUTING

SEE SHEET CU206 AND CU207

PATH A.4

SEE SHEET CU206

SCALE: 1" = 20'

SANITARY, 12" PVC,INV 550.01, ADJUST

DUCTBANK ALIGNMENT IF IN CONFLICT

66' DUCT 4 -4" CONDUIT

KEYED NOTES

1 INSTALL 90-DEGREE BEND (MIN 4'R) UNDER MODULAR

BUILDING AND ENTER BUILDING THROUGH THE

FLOOR.

NOTE:

1. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE BEEN

PLOTTED FROM AVAILABLE SURVEYS AND RECORDS. THEIR LOCATIONS

MUST BE CONSIDERED TO BE APPROXIMATE ONLY. IT IS POSSIBLE

THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS NOT PRESENTLY

KNOWN OR SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO

DETERMINE THEIR EXISTENCE AND EXACT LOCATION AND TO AVOID

DAMAGE THERETO, WHICH SHALL INCLUDE ADJUSTMENTS OR

RELOCATIONS AS NECESSARY TO COMPLETE THE WORK SHOWN.

2. ALL OPEN TRENCHES MUST HAVE A 48-INCH TALL, ORANGE MESH FENCE

SURROUNDING THE AREA.

3. INSTALL TOP OF DUCT BANK AT LEAST 24 INCHES BELOW FINISHED

GRADE IN AREAS NOT SUBJECT TO DELIBERATE TRAFFIC, AND AT LEAST

30 INCHES BELOW FINISHED GRADE IN DELIBERATE TRAFFIC PATHS FOR

VEHICLES.

4. CONTRACTOR SHALL REFER TO THE TECHNOLOGY PLANS TO ENSURE

CONDUIT FROM DUCTBANKS ENTER EACH BUILDING AT THE INTENDED

ROOM AND LOCATION. ADJUST DUCTBANK ALIGNMENT IF NEEDED.

2 CONTRACTOR TO INSTALL CONDUIT INTO BUILDING IN ACCORDANCE TO

THE VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL,

(PSRDM), LATEST EDITION.

PROVIDE AND INSTALL 4" SCH. 80 CONCRETE ENCASED DUCT BANK

ENCLOSURE. CONTRACTOR TO PROVIDE PULL-STRING

THROUGHOUT ENTIRE LENGTH OF CONDUITS.

204049

ELECTRIC

EL

EC

TR

IC

EL

EC

TR

IC

EL

EC

TR

IC

EL

EC

TR

IC

ST

ORM

ST

OR

M

W

AT

ER

11+00 12+00 12+53

EL

EC

TR

IC

FI

BE

R

OP

TI

C

W

AT

ER

ELE

CTR

IC

+0

+0

+6

+0

10+80 11+00 12+00 12+80

3.8

3.1

3.5

2.0

1.3

1.0

0.4

0.5 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

A

B

C

D

E

F

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SETH ANDREW CAVIN - ARCHITECT

JAMES ROSS MYLES - MECHANICAL ENGINEER

BENJAMIN ELIAS NOE - ELECTRICAL ENGINEER

#011.023503 EXP. 11/30/2022

#062.071715 EXP. 11/30/2023

#062.072296 EXP. 11/30/2023

CIVIL/ STRUCTURAL ENGINEER

OATES ASSOCIATES

100 LANTER COURT, SUITE 1

COLLINSVILLE, IL 62234

(618) 345-2200

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

DATA/COMM CONSULTANT

ASPEN ENGINEERING & CONSTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 86301

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

STAMP:

Drawing Number

Building Number

EHRM INFRASTRUCTURE

UPGRADES

COMMISSIONING AGENT

ES2

13401 N. SANTA FE AVE.

OKLAHOMA, OK 73114

(405) 528-4500

A

M

AM

PHJ

FINAL BID DOCUMENTS

04/20/2023

657A5-21-700

MARION VA MEDICAL CENTER

2401 WEST MAIN ST.

MARION, IL 62959

SPUR #: 2114

No. REVISION DESCRIPTION DATE

CONTROLLED UNCLASSIFIED INFORMATION - CUI

CONTROLLED UNCLASSIFIED INFORMATION - CUI

N

SCALE: 1" = 20'

CU212

PATH A.10

BUILDING 43

DINING

ROOM 170

EXAM

ROOM 126

PATH A.10

NEW FIBER DUCTBANK

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK, (TYP.),

SEE DETAIL 1 ON SHEET CU400

PATH B.9

SEE SHEET CU211

BLDG 42

BLDG 43

EXISTING GROUND

STA 12+24 TO 12+35

REMOVE AND REPLACE EXISTING

CONCRETE SIDEWALK,

SEE DETAIL 1 ON SHEET CU400STORM SEWER 12" RCP, APPROX. INV 457.30

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

FIBER OPTIC, WATER AND ELECTRIC, UNKNOWN DEPTH

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

PATH A.11

SEE SHEET CU213

SE

E

SH

EE

T

CU

SEE SHEET CU213

FIBER PLAN & PROFILE

153' DUCT 4-4" CONDUIT

BUILDING 42

NOTE:

1. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE BEEN

PLOTTED FROM AVAILABLE SURVEYS AND RECORDS. THEIR

LOCATIONS MUST BE CONSIDERED TO BE APPROXIMATE ONLY. IT IS

POSSIBLE THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS NOT

PRESENTLY KNOWN OR SHOWN. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO DETERMINE THEIR EXISTENCE AND EXACT

LOCATION AND TO AVOID DAMAGE THERETO, WHICH SHALL INCLUDE

ADJUSTMENTS OR RELOCATIONS AS NECESSARY TO COMPLETE THE

WORK SHOWN.

2. ALL OPEN TRENCHES MUST HAVE A 48-INCH TALL, ORANGE MESH

FENCE SURROUNDING THE AREA.

3. INSTALL TOP OF DUCT BANK AT LEAST 24 INCHES BELOW FINISHED

GRADE IN AREAS NOT SUBJECT TO DELIBERATE TRAFFIC, AND AT

LEAST 30 INCHES BELOW FINISHED GRADE IN DELIBERATE TRAFFIC

PATHS FOR VEHICLES.

4. CONTRACTOR SHALL REFER TO THE TECHNOLOGY PLANS TO

ENSURE CONDUIT FROM DUCTBANKS ENTER EACH BUILDING AT THE

INTENDED ROOM AND LOCATION. ADJUST DUCTBANK ALIGNMENT IF

NEEDED.

KEYED NOTES

1 CONTRACTOR TO INSTALL CONDUIT INTO BUILDING IN ACCORDANCE TO

THE VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL,

(PSRDM), LATEST EDITION.

1 1

PROVIDE AND INSTALL 4" SCH. 80 CONCRETE ENCASED DUCT BANK

ENCLOSURE. CONTRACTOR TO PROVIDE PULL-STRING

THROUGHOUT ENTIRE LENGTH OF CONDUITS.

204050

15+75

11+00

+0

+0

14+00 15+00

10+60 11+00 12+00 13+00 14+00 15+00 16+00 16+20

2.8

2.3

2.5

2.3

1.4

0.7

0.2

0.0

9.9

0.5

1.9

2.6

3.9

5.3

7.5

8.4

8.7

8.9

8.7

8.3

8.3

8.3

8.3

8.2 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

A

B

C

D

E

F

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SETH ANDREW CAVIN - ARCHITECT

JAMES ROSS MYLES - MECHANICAL ENGINEER

BENJAMIN ELIAS NOE - ELECTRICAL ENGINEER

#011.023503 EXP. 11/30/2022

#062.071715 EXP. 11/30/2023

#062.072296 EXP. 11/30/2023

CIVIL/ STRUCTURAL ENGINEER

OATES ASSOCIATES

100 LANTER COURT, SUITE 1

COLLINSVILLE, IL 62234

(618) 345-2200

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

DATA/COMM CONSULTANT

ASPEN ENGINEERING & CONSTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 86301

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

EHRM INFRASTRUCTURE

UPGRADES

COMMISSIONING AGENT

ES2

13401 N. SANTA FE AVE.

OKLAHOMA, OK 73114

(405) 528-4500

A

M

AM

PHJ

FINAL BID DOCUMENTS

04/20/2023

657A5-21-700

MARION VA MEDICAL CENTER

2401 WEST MAIN ST.

MARION, IL 62959

SPUR #: 2114

No. REVISION DESCRIPTION DATE

CONTROLLED UNCLASSIFIED INFORMATION - CUI

CONTROLLED UNCLASSIFIED INFORMATION - CUI

N

SCALE: 1" = 20'

BUILDING 43

BUILDING 14

CU213

PATH A.11

STA. 13+03 TO 13+13

REMOVE AND REPLACE EXISTING CONCRETE SIDEWALK

SEE DETAIL 1 ON SHEET CU400

BLDG 43

BLDG 14

EXISTING GROUND

WATER, ESTIMATED 7' DEEP,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

SANITARY SEWER, 8" PVC, APPROX. INV. 442.50,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

4 BED

ROOM 131

BOILER

ROOM 105

PATH A.11

FENCE, TO BE REMOVED AND REPLACED BY CONTRACTOR

6' RADIUS (TYP)

REMOVE AND REPLACE EXISTING CONCRETE SIDEWALK, (TYP.),

SEE DETAIL 1 ON SHEET CU400

REMOVE AND REPLACE EXISTING CONCRETE

SIDEWALK AND ASPHALT PAVEMENT, (TYP.),

SEE DETAIL 1 ON SHEET CU400

FIBER PLAN & PROFILE

STA. 11+03 TO 11+06

REMOVE AND REPLACE EXISTING CONCRETE SIDEWALK

SEE DETAIL 1 ON SHEET CU400

STA. 11+24 TO 11+72

REMOVE AND REPLACE EXISTING GRAVEL PARKING AREA

WATER, UNKNOWN DEPTH,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICTSANITARY SEWER, UNKNOWN DEPTH,

ADJUST DUCTBANK ALIGNMENT IF IN CONFLICT

STA. 11+75

COMM. MANHOLE

4' X 4'

TOP: 451.58

STA. 11+75

COMM. MANHOLE

4' X 4'

TOP: 457.35

76' DUCT 4 -4" CONDUIT 199' DUCT 4-4" CONDUIT 200' DUCT 4-4" CONDUIT

6' RADIUS (TYP)

NOTE:

1. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE

BEEN PLOTTED FROM AVAILABLE SURVEYS AND RECORDS. THEIR

LOCATIONS MUST BE CONSIDERED TO BE APPROXIMATE ONLY. IT IS

POSSIBLE THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS

NOT PRESENTLY KNOWN OR SHOWN. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO DETERMINE THEIR EXISTENCE AND EXACT

LOCATION AND TO AVOID DAMAGE THERETO, WHICH SHALL

INCLUDE ADJUSTMENTS OR RELOCATIONS AS NECESSARY TO

COMPLETE THE WORK SHOWN.

2. ALL OPEN TRENCHES MUST HAVE A 48-INCH TALL, ORANGE MESH

FENCE SURROUNDING THE AREA.

3. INSTALL TOP OF DUCT BANK AT LEAST 24 INCHES BELOW FINISHED

GRADE IN AREAS NOT SUBJECT TO DELIBERATE TRAFFIC, AND AT

LEAST 30 INCHES BELOW FINISHED GRADE IN DELIBERATE TRAFFIC

PATHS FOR VEHICLES.

4. CONTRACTOR SHALL REFER TO THE TECHNOLOGY PLANS TO

ENSURE CONDUIT FROM DUCTBANKS ENTER EACH BUILDING AT

THE INTENDED ROOM AND LOCATION. ADJUST DUCTBANK

ALIGNMENT IF NEEDED.

KEYED NOTES

1 CONTRACTOR TO INSTALL CONDUIT INTO BUILDING IN ACCORDANCE TO

THE VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL,

(PSRDM), LATEST EDITION.

MH

MH

MH

MH

REMOVE AND REPLACE GRAVEL PARKING

AREA IN KIND.

PROVIDE AND INSTALL 4" SCH. 80 CONCRETE ENCASED DUCT BANK

ENCLOSURE. CONTRACTOR TO PROVIDE PULL-STRING

THROUGHOUT ENTIRE LENGTH OF CONDUITS.

ELEV. 446.57

ELEV. 447.82

ELEV. 453.05

ELEV. 453.05

204051

049_CU211 - FIBER PLAN & PROFILE
050_CU212 - FIBER PLAN & PROFILE
051_CU213 - FIBER PLAN & PROFILE

File details come from the government source that posted it. Updated .