S02 - Construction Documents Bid Set 3 - DRAFT.pdf
PDF 27 MB Posted
- Attached to
- Z1DA--640-13-134 PAD Hybrid Cath Lab OR Upgrades
- Solicitation number
- 36C26121R0079
About this file
This notice describes an upcoming federal contract opportunity for construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 plans to issue a Request for Proposal to complete construction of a new Catheterization Laboratory Hybrid Operating Room Suite and install a rooftop air handling unit at the VA Palo Alto Health Care System campus in Palo Alto, California. The construction period is 365 days with a projected value between $5 million and $10 million. The NAICS code for this project is 236220. Offerors must register in the System for Award Management and have a current Online Representations and Certifications Application on file by the solicitation due date and date of contract award. Eligible small businesses include verified Service-Disabled Veteran-Owned and Veteran-Owned Small Businesses. The solicitation is anticipated for issue after November 4, 2021.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MARK
100-PF6A1
100-PF6A2
100-PF6A3
100-AF6A
100-FF1
LOCATION
B100 ROOF
B100 B100 ROOF
B100 ROOF
B100 ROOF
B100 ROOF
AREA AND/OR BLDG
SERVED
2 CARDIO
2 CARDIO
2 CARDIO
2 CARDIO
2 CARDIO
SYSTEM
AND/OR
SERVICE
100-AHU6A
100-AHU6A
100-AHU6A
100-AHU6A
100-AHU6A
EXISTING AIR FILTER SCHEDULE
APD
MERV
RATING
CFM
11000
11000
11000
11000
11000
[L/s]
[ 5200 ]
[ 5200 ]
[ 5200 ]
[ 5200 ]
[ 5200 ]
IN
0.59
0.37
0.59
0.31
1.0
AIR FLOW
INITIAL
[mm]
[ 15 ]
[ 9 ]
[ 15 ]
[ 8 ]
[ 25 ]
CHANGEOVER
IN
1.09
0.87
1.59
0.81
NOTE 3
HOUSING
TYPE
SIDE
SIDE
SIDE
SIDE
SIDE
DEPTH
AS REQ'D N/A
[mm]
EXISTING AIR FLOW CONTROL VALVE SCHEDULE
CARTRIDGES
SIZE
ARRANGEMENT REMARKS
6A-E001
6A-E002
6A-E003
MARK
SYSTEM
AND/OR
SERVICE
SIZE
TYPE
IN
100-AHU-6A
100-AHU-6A
100-AHU-6A
3x12
2x12
[mm]
3x[300]
2x[300]
[ 200 ]
MAX AIR FLOW
TYPE
[ 1500 ]
[ 700 ]
[ 150 ]
[ 610 ]
[ 350 ]
[ 140 ]
0.3
0.3
0.3
[ 75 ]
[ 75 ]
[ 75 ]
SEE NOTES
VAV
CAV
APPLICATION
HYBRID OR
EQUIPMENT RM
CONTROL RM
REMARKS
NOTE 1: PRICE VV LOW PRESSURE
NOTES
1. NOT USED.
2. FILTER UPSTREAM OF 100-ERC6A2
3. PER MANUFACTURER'S RECOMMENDATIONS
NOTES
1. TWO POSITION, PRESSURE INDEPENDENT VALVE. DURING UNOCCUPIED MODE, EXHAUST AIR SHALL TRACK SUPPLY AIR TO MAINTAIN AIR FLOW DIFFERENTIAL
2. SEE FLOOR PLANS FOR LOCATIONS
3. SEE DETAIL 4/MI701 FOR CONTROLS.
AIR FLOW
MARK
6-253
6-254
6A-001
6A-002
6A-003
SYSTEM AIR
HANDLING
100-AHU-6A
100-AHU-6A
100-AHU-6A
100-AHU-6A
100-AHU-6A
SIZE
C
E
K
I
D
MAX
[ 212 ]
[ 270 ]
[ 1504 ]
[ 454 ]
[ 89 ]
CFM
1,515
MIN
[L/s]
[ 212 ]
[ 183 ]
[ 412 ]
[ 454 ]
[ 45]
CAV
SEE NOTES
CAV
1/MI702
2/MI702
2/MI702
1/MI702
2/MI702
CONTROL
TYPE
EXISTING SINGLE DUCT AIR TERMINAL UNIT SCHEDULE
CONTROL
SEQUENCE
EAT
65 [ 18 ]
[ 18 ]
[ 11 ]
[ 11 ]
[ 11 ]
EWT
[ 82 ]
[ 82 ]
[ 82 ]
[ 82 ]
[ 82 ]
0.6
4.6
1.9
0.5
NOTES
1. VAV: TWO-POSITION, PRESSURE INDEPENDENT BOX. DURING UNOCCUPIED MODE, SUPPLY AIR SHALL TURN DOWN TO MIN CFM POSITION. SEE AIRFLOW TABLE FOR FURTHER INFORMATION.
2. SEE FLOOR PLANS FOR LOCATIONS
MARK
100-CWCC6A
LOCATION
B100 ROOF
AREA AND/OR
BLDG SERVED
2 CARDIO
SYSTEM
AND/OR
SERVICE
100-AHU6A
EAT
AIR FLOW
CFM
11000
[L/s]
[ 5200 ]
MAX FACE VELOCITY
FPM [M/s]
500 [ 3 ]
NOTE
THE COOLING COIL FIN SPACING SHALL NOT EXCEED 132 FINS PER FOOT [400 FINS PER METER].
MARK LOCATION
100-ERC6A1
100-ERC6A2
100-ERC6A1
100-ERC6A2
AREA AND/OR
BLDG
2 CARDIO
2 CARDIO
2 CARDIO
2 CARDIO
SYSTEM
AND/OR
SERVICE
100-AHU6A
100-AHU6A
100-AHU6A
100-AHU6A
AIR FLOW
APPLICATION
SUPPLY COIL
EXHAUST COIL
SUPPLY COIL
EXHAUST COIL
NOTES
1. PROVIDE A VA GRADE A PREFILTER AT EXHAUST COIL INLET.
2. PROVIDE SUPPLY COIL WITH COPPER FINS.
MARK
100-ACCH6A
LOCATION
B100 ROOF
AREA AND/OR
BLDG SERVED
2 CARDIO
MIN OUTPUT
CAPACITYTYPE
SCROLL
TONS
66.30
[kW]
[ 232 ]
NOTES
1. SEE SPECIFICATIONS FOR OTHER APPLICABLE ENGINEERING REQUIREMENTS.
2. "MAX kW/TON" SPECIFIED ARE AT DESIGN CONDITIONS INDICATED. kW/TON INCLUDES CONDENSER FANS.
3. OPERATING WEIGHT, 3500 LBS. PROVIDE WITH EMERGENCY POWER.
1.03 0.86
MAX
kW/TON
MAX IPLV
(kW/TON) FLOW
EXISTING AIR COOLED CHILLER SCHEDULE
EVAPORATOR
LWTEWT
GPM [L/s]
96.2 [ 6 ]
°F
[°C]
[ 14 ]
°F
[°C]
[ 7 ]
FT
6.9
CFM
11000
11000
11000
11000
[L/s]
[ 5200 ]
[ 5200 ]
[ 5200 ]
[ 5200 ]
FPM
[ 2 ]
[ 2 ]
[ 2 ]
[ 2 ]
IN WG
0.44
0.46
0.4
0.42
[Pa]
[ 110 ]
[ 120 ]
[ 100 ]
[ 110 ]
°F
35.7
MAX FACE VELOCITY APD
Db
[°C]
[ 2 ]
[ 22 ]
[ 35 ]
[ 24 ]
°F
69.5
Wb
[°C]
[ 16 ]
[ 21 ]
°F
56.8
84.6
85.6
Db
[°C]
[ 14 ]
[ 11 ]
[ 29 ]
[ 30 ]
°F
66.3
Wb
[°C]
[ 11 ]
[ 19 ]
MBH
[kW]
[ 920 ]
[ 920 ]
[ 430 ]
[ 430 ]
EXISTING HEAT RECOVERY SYSTEM RUN AROUND WATER COIL SCHEDULE
EAT LAT
TOTAL MIN CAPACITY
FLOW
GPM
[ 1 ]
[ 1 ]
[ 1 ]
[ 1 ]
°F
67.4
40.6
77.3
89.9
EWT
[°C]
[ 20 ]
[ 5 ]
[ 25 ]
[ 32 ]
°F
40.6
67.4
89.9
77.3
LWT
[°C]
[ 5 ]
[ 20 ]
[ 32 ]
[ 25 ]
FT
6.3
6.3
5.89
5.89
WPD
[M]
[ 2 ]
[ 2 ]
[ 2 ]
[ 2 ]
PUMP NO
100-ERP6A1,2
100-ERP6A1,2
REMARKS
WINTER CONDITION
SUMMER CONDITION
MAX APD
Db
IN WG [Pa]
0.66 [ 170 ] 95 [ 35 ]
°F
69.5
Wb
[°C]
[ 21 ]
°F
46.5
Db
[°C]
[ 8 ]
°F
46.5
Wb
[°C]
[ 8 ]
MBH [kW]
[ 220 ] 579
[kW]
[ 170 ]
EXISTING CHILLED WATER COOLING COIL SCHEDULE
LAT
TOTAL CAPACITY SENSIBLE CAPACITY
FLOW
GPM
105 [ 7 ]
°F
EWT
[°C]
[ 7 ]
°F
LWT
[°C]
[ 14 ]
FT
WPD
[M]
[ 5 ]
REMARKS
PROVIDE WITH COPPER FINS.
[ 2 ]
[ 2 ]
REHEAT HOT WATER HEATING COIL
FLOW MAX WPD
0.5
[ 17 ]
[ 7 ]
[ 2 ]
FT
[kPa]
[ 12 ]
[ 9 ]
[ 12 ]
[ 12 ]
[ 12 ]
UNIT MARK
PIPE RUNOUT SIZE TO COIL
IN
0.75
0.75
0.75
0.75
[mm]
[ 19 ]
[ 19 ]
[ 25 ]
[ 19 ]
[ 19 ]
REMARKS
TITUS DESV
NOTE 1; TITUS DESV
TITUS DESV
OPERATING MODE
SERVICE
QTY. / LOCATION (INDOOR/OUTDOOR)
ELECTRICAL
MOTOR HP
MAX. MOTOR RPM
MOTOR VOLTAGE
OPTIONS
WEATHER-PROOF ENCLOSURE
INTEGRAL DISCONNECT
INTEGRAL BYPASS
BMS COMMUNICATION CARD
REMARKS
NOTES/REMARKS:
1. DRIVES SHALL INCLUDE MANUAL 3-CONTACTOR BYPASS, CIRCUIT BREAKER DISCONNECT, HOA SWITCH, LINE REACTORS,5 YEAR WARRANTY AND AUTHORIZED FACTORY STARTUP. SEE VFD CONTROL DIAGRAM
FOR ADDITIONAL DETAILS ON CONTROLS DRAWING.
2. VFD SHALL BE FACTORY MOUNTED AND WIRED AS A PART OF THE SERVING AIR HANDLING UNIT PACKAGE.
100-VFD-AHU-6A
DESIGN
AHU-6A (SUPPLY)
2 / OUTDOOR
24.0
3,500
460-3-60
YES - NEMA 3R
YES
YES
YES
1, 2
EXISTING VARIABLE FREQUENCY DRIVE SCHEDULE
100-VFD-SCHP-6A1
DESIGN
100-VFD-AHU-E6A
DESIGN
AHU-6A (EXHAUST)
2 / OUTDOOR
16.0
1,750
460-3-60
YES - NEMA 3R
YES
YES
YES
1, 2
100-SCHP6A1
1 / OUTDOOR
2.0
1,750
460-3-60
YES - NEMA 3R
YES
YES
YES
100-VFD-SCHP-6A2
DESIGN
100-SCHP6A2
1 / OUTDOOR
2.0
1,750
460-3-60
YES - NEMA 3R
YES
YES
YES
CHILLED WATER
CHILLED WATER
CONDENSER
ELECTRICAL
MAX WPD
[kPa]
[ 20.6 ]
FOULING
FACTOR
0.0001
AMBIENT OA TEMP
°F
REMARKS
[°C]
[ 35 ] 138 150
PHASE VOLT
3 460 DAIKIN AGZ070E
EXISTING PUMP SCHEDULE
MARK
100-ERP6A1,2
100-SCHP1,2
LOCATION
B100 ROOF
B100 ROOF
AREA AND/OR
BLDG SERVED
2 CARDIO
SYSTEM AND/OR
SERVICE
HEAT RECOVERY
TYPE
FLUID
IN-LINE
2 CARDIO
NOTES
1. REDUNDANT PUMPS. PROVIDE WITH EMERGENCY POWER.
2. PROVIDE WITH VFD. LIMIT MIN FLOW PER MANUFACTURER'S RECOMMENDATION.
3. B&G PL-45. OPERATING WEIGHT, 20 LBS
4. B&G e-1510 1.5BC. OPERATING WEIGHT, 250 LBS
HEAT RECOVERY WATER
CHILLED WATER
GPM
[ 1 ]
[ 7 ]
FT
[kPa]
[ 320 ]
[ 1000 ]
FLOW
CIRCULATING FLUID
HEAD
ELECTRICAL MOTOR
NPSH AVAILABLE
FT
N/A
N/A
TEMPERATURE
SP GR
[kPa] °F
[°C]
[ 25 ]
[ 7 ]
N/A
60%
MIN % EFF NOMINAL POWER
HP
0.1667
[kW]
[ 4 ]
PHASE
VOLT
SPEED
CONTROL
CONSTANT
VARIABLE
REMARKS
NOTE 1 , 3
NOTE 1, 2, 4
[L/m]MBH
MCA MOP
BACKUP CHILLER WATER END SUCTION
[L/s]
MAX RPM
B100 ROOF
B100 ROOF
B100 ROOF
B100 ROOF
[L/s][M/s]
MAX AIR FLOW
APD AT MAX
AIR FLOW CONTROL
CFM [L/s] CFM [L/s] IN WG [pa]
°F [°C] °F [°C] GPM [L/m]CFM [L/s]
AIR FLOW
MARK
6A-007
SYSTEM AIR
HANDLING
100-AHU-6A
SIZE
G 950
MAX
[ 447 ]
CFM
MIN
[L/s]
[ 148 ] VAV 1/MI702
CONTROL
TYPE
NEW SINGLE DUCT AIR TERMINAL UNIT SCHEDULE
CONTROL
SEQUENCE
EAT
65 [ 18 ] 180
EWT
[ 82 ]
NOTES
2. SEE FLOOR PLANS FOR LOCATIONS
[ 4 ]
REHEAT HOT WATER HEATING COIL
FLOW MAX WPD
1.1
FT
.15
[kPa]
[ .45 ]
PIPE RUNOUT SIZE TO COIL
IN
0.75
[mm]
[ 19 ]
REMARKS
NOTE 1: TITUS DESV
°F [°C] °F [°C] GPM [L/m]CFM [L/s]
1. VAV: TWO-POSITION, PRESSURE INDEPENDENT BOX. DURING UNOCCUPIED MODE, SUPPLY AIR SHALL TURN DOWN TO MIN CFM POSITION. SEE AIRFLOW TABLE FOR FURTHER INFORMATION.
SEE NOTES
SEE NOTES NOTE 1; TITUS DESV
NOTE 1; TITUS DESV
NOTE 1: PRICE VV LOW PRESSURE
NOTE 1: PRICE VV LOW PRESSURE
SEE NOTES
SEE NOTES
SEE NOTES
3. SEE ELECTRICAL DRAWINGS FOR COORDINATION.
4. SEE STRUCTURAL DETAIL 3/SS701 FOR CHILLER CURB AND ANCHORAGE.
6-233 100-AHU-6A E 555 [ 261 ] 555 [ 261 ] CAV 2/MI702 65 [ 18 ] 180 [ 82 ] [ 2.27 ]0.6 .11 [ .45 ] 0.75 [ 19 ]
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E
T S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH003
MECHANICAL SCHEDULES
WHERE INDICATED AS "EXISTING" EQUIPMENT IS
OWNER FURNISHED AND CONTRATOR INSTALLED.
EXISTING EQUIPMENT SCHEDULED DATA IS SHOWN
FOR REFERENCE ONLY.
Revisions: Date:
EXISTING EXPANSION TANK SCHEDULE
MARK
100-ET6A
100-ETERC HEAT RECOVERY LOOP DIAPHRAGM 300 [ 1100 ] 40 [ 4 ] 90 [ 32 ] 12 [ 83 ] 125 [ 860 ] 125 [ 860 ]
MARK
100-PHC6A
LOCATION
B100 ROOF
AREA AND/OR
BLDG SERVED
2 CARDIO
SYSTEM
AND/OR
SERVICE
100-AHU6A
EXISTING STEAM HEATING COIL SCHEDULE
TEMPERATURES
AIR FLOW
APPLICATION
PREHEAT
CFM
11000
[L/s]
[ 5200 ]
FPM
513 [2.6] 0.17
°F
[ 42 ] 55
MAX FACE VELOCITY APD
EAT
[°C]
[ 13 ]
°F
LAT
[°C]
[ 57 ]
MBH
[kW]
[ 266 ]
TOTAL MIN CAPACITY
ENT CONT VALVE
PSIG
ENT COIL
[kPa]
[ 210 ]
PSIG
[kPa]
[ 210 ] 300
FLOW
[ 136 ]
STEAM TRAP
ST2 1030 [ 467 ]
REMARKS
WING VB-8T
12 [ 83 ] 8 [ 30 ] 2.4 [ 9 ] 0.5 [ 13 ]
LOCATION
B100 ROOF
SYSTEM AND/OR
SERVICE
BACKUP CHILLED WATER
TYPE
BLADDER
APPROX SYSTEM
VOLUME
GAL
[L]
[ 1300 ]
°F
SYSTEM TEMPERATURE RANGE
MIN MAX
[°C]
[ 4 ]
°F
[°C]
[ 38 ]
INITIAL PRESSURE IN
TANK
12 [ 83 ]
MAX OPERATING
PRESSURE
125 [ 860 ]
FILL PRESSURE AT TANK
MIN VOLUME TANK
RELIEF VALVE
125 [ 860 ]
AT TANK
12 [ 83 ] 1.6
[L]
[ 6 ]
MIN BLADDER
VOLUME
GAL
1.3
[L]
[ 5 ]
PIPE SIZE TO TANK
REMARKS
IN
[mm]
[ 25 ]
B&G SERIES B-35LA; OPERATING WT 160
LBS
B&G SERIES D-15V; OPERATING WT 120
LBS
STEAM
WATER CONDITIONS
MARK
100-SSHX6A 2 CARDIO
LOCATION
AREA AND/OR
BLDG SERVED
SYSTEM AND/OR
SERVICE
TYPE
SOURCE OF
MAKEUP
FLOW
GPM [L/s]
0.5 [ 0. ]
°F
EWT
[°C]
[ 16 ]
LBS/HR
NOTES
1. STS-200S. OPERATING WEIGHT OF 670 LBS, 120V ELECTRICAL CONNECTION
2. MAKE UP WATER SHALL BE SOFTENED. SEE PLUMBING DRAWINGS
3. PROVIDE WITH CAPABILITY TO CHANGE TO DI/RO MAKE UP WATER AT A FUTURE DATE. SS HEAT EXCHANGER WITH TEFLON COATING.
4. PROVIDE DRAIN COOLER QUENCHING ACCESSORY SUCH THAT CONDENSATE IS LESS THAN 140 F AT DRAIN.
AIR FLOW
MAX APD
MARK
SD-11
SD-12
SD-13
SD-14
SD-15
SD-16
SD-21
SD-22
SD-23
SD-24
SD-25
SD-26
SD-51
SD-52
SD-53
SD-54
SD-55
SD-56
SD-57
SD-58
TYPE
LOUVERED FACE
LOUVERED FACE
LOUVERED FACE
LOUVERED FACE
LOUVERED FACE
LOUVERED FACE
PERFORATED
PERFORATED
PERFORATED
PERFORATED
PERFORATED
PERFORATED
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
MIN
[ 19 ]
[ 33 ]
[ 52 ]
[ 76 ]
[ 100 ]
[ 120 ]
[ 28 ]
[ 52 ]
[ 76 ]
[ 110 ]
[ 100 ]
[ 130 ]
[ 38 ]
[ 38 ]
[ 61 ]
[ 94 ]
[ 190 ]
[ 170 ]
[ 260 ]
[ 590 ]
MAX
40 [ 76 ]
[ 130 ]
[ 180 ]
[ 220 ]
[ 300 ]
[ 350 ]
[ 85 ]
[ 150 ]
[ 210 ]
[ 330 ]
[ 450 ]
[ 570 ]
[ 57 ]
[ 76 ]
[ 170 ]
[ 240 ]
[ 330 ]
[ 330 ]
[ 520 ]
[ 1400 ]
0.080
0.100
0.090
0.080
0.090
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.090
0.080
0.100
0.080
0.070
0.070
0.100
NOTES
1. SEE FLOOR PLAN FOR THROW PATTERN.
2. SEE DETAIL FOR DAMPER IN BRANCH DUCT SERVING EACH DIFFUSER.
3. PROVIDE SQUARE TO ROUND ADAPTER.
AIR FLOW
MARK
RG-21
RG-22
RG-23
RG-24
RG-25
RG-26
RR-51
RR-52
RR-53
RR-54
RR-55
RR-56
RR-57
RR-58
RR-59
TYPE
PERFORATED
PERFORATED
PERFORATED
PERFORATED
PERFORATED
PERFORATED
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RETURN REGISTER
RR-510 RETURN REGISTER
RR-511 RETURN REGISTER
RR-512 RETURN REGISTER
RR-513 RETURN REGISTER
MIN
NOTE
PROVIDE SQUARE TO ROUND ADAPTER.
[ 28 ]
[ 52 ]
[ 80 ]
[ 110 ]
[ 150 ]
[ 200 ]
[ 61 ]
[ 94 ]
[ 130 ]
[ 120 ]
[ 150 ]
[ 42 ]
[ 66 ]
[ 99 ]
[ 90 ]
[ 100 ]
[ 160 ]
[ 170 ]
[ 220 ]
MAX
[ 47 ]
[ 80 ]
[ 120 ]
[ 190 ]
[ 240 ]
[ 330 ]
[ 99 ]
[ 160 ]
[ 210 ]
[ 290 ]
[ 380 ]
[ 76 ]
[ 110 ]
[ 170 ]
[ 150 ]
[ 170 ]
[ 260 ]
[ 400 ]
[ 590 ]
0.088
0.088
0.088
0.088
0.087
0.087
0.078
0.078
0.078
0.082
0.082
0.078
0.078
0.078
0.078
0.078
0.078
0.082
0.095
22.000
22.000
22.000
22.000
22.000
22.000
20.000
20.000
20.000
21.000
21.000
20.000
20.000
20.000
20.000
20.000
20.000
21.000
24.000
MAX APD
EXISTING AIR DEVICE SCHEDULE (RETURN AND EXHAUST)
PANEL/FRAME SIZE
MOUNTING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
IN x IN
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
10 x 10
12 x 12
14 x 14
16 x 16
18 x 18
10 x 8
14 x 8
20 x 8
14 x 10
14 x 12
20 x 12
26 x 14
32 x 14
[mm x mm]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 254 x 254 ]
[ 305 x 305 ]
[ 356 x 356 ]
[ 406 x 406 ]
[ 457 x 457 ]
[ 254 x 203 ]
[356 x 203 ]
[ 508 x 203 ]
[ 356 x 254 ]
[ 356 x 305 ]
[ 508 x 305 ]
[ 660 x 356 ]
[ 813 x 356 ]
IN x IN
6 DIAM
8 DIAM
10 DIAM
12 DIAM
14 DIAM
16 DIAM
8 x 8
10 x 10
12 x 12
14 x 14
16 x 16
8 x 6
12 x 6
18 x 6
12 x 8
12 x 10
18 x 10
24 x 12
30 x 12
[mm x mm]
[ 152 DIAM ]
[ 203 DIAM ]
[ 254 DIAM ]
[ 305 DIAM ]
[ 356 DIAM ]
[ 406 DIAM ]
[ 203 x 203 ]
[ 254 x 254 ]
[ 305 x 305 ]
[ 356 x 356 ]
[ 406 x 406 ]
[ 203 x 152]
[ 305 x 152 ]
[ 457 x 152 ]
[ 305 x 203 ]
[ 305 x 254 ]
[ 457 x 254 ]
[ 600 x 305 ]
[ 762 x 305 ]
[ 20 ]
[ 25 ]
[ 23 ]
[ 20 ]
[ 23 ]
[ 25 ]
[ 25 ]
[ 25 ]
[ 25 ]
[ 25 ]
[ 25 ]
[ 25 ]
[ 25 ]
[ 23 ]
[ 20 ]
[ 25 ]
[ 20 ]
[ 18 ]
[ 18 ]
[ 25 ]
MOUNTING
IN x IN
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
8 x 8
12 x 8
14 x 10
14 x 12
18 x 12
18 x 18
22 x 22
32 x 32
[mm x mm]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[ 600 x 600 ]
[203 x 203]
[305 x 203]
[356 x 254]
[356 x 305]
[508 x 305]
[457 x 457]
[560 x 560]
[813 x 813]
IN
6 ø
8 ø
10 ø
12 ø
14 ø
16 ø
6 ø
8 ø
10 ø
12 ø
14 ø
16 ø
6 x 6
10 x 6
12 x 8
12 x 10
18 x 10
16 x 16
20 x 20
30 x 30
[mm ]
[152 ø]
[203 ø]
[254 ø]
[305 ø ]
[356 ø ]
[406 ø ]
[152 ø ]
[203 ø ]
[254 ø ]
[305 ø ]
[356 ø ]
[406 ø ]
[152 x 152]
[254 x 152]
[305 x 203]
[305 x 254]
[457 x 254]
[406 x 406]
[508 x 508]
[762 x 762]
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
100-F/SDPR1
100-F/SDPR2
2ND FL
2ND FL
100-SF6A1, 2
100-EF6A1, 2
100-AHU6A
100-AHU6A
MARK LOCATION
FAN SYSTEM
SMOKE AND COMBINATION FIRE/SMOKE DAMPER SCHEDULE
DUCT SIZESYSTEM
AND/OR
SERVICE
DUCT PRESSURE
CLASS
IN
38x30
38x30
[mm]
[965 x 762]
[965 x 762]
[ 1000 ]
[ 500 ]
REMARKS
DAMPER FINISH REMARKS
EXISTING AIR DEVICE SCHEDULE (SUPPLY)
PANEL/FRAME SIZE
kg/HR
[ 177 ]
EXISTING CLEAN STEAM GENERATOR SCHEDULE
PRODUCED STEAM
PRESS
0 [ ] 15
EXISTING BUFFER TANK SCHEDULE
STEAM PRESSURE
PSIG [kPa]
[ 100 ]
ENT HEAT
EXCHANGER
PSIG [kPa]
15 [ 100 ]
LBS/HR
[kg/HR]
[ 177 ]
CONTROL VALVE REMARKS
MARK
100-BT6A
ST4 NOTES 1-4
B100 ROOF
TRAP
MARK LOCATION
SYSTEM AND/OR
SERVICE
BACKUP CHILLED WATER
TYPE
BUFFER TANK
APPROX SYSTEM
VOLUME
GAL
[L]
[ 1300 ]
MAX OPERATING
PRESSURE
[ 860 ]125 120
MIN VOLUME TANK
[L]
[ 450 ]
IN
[mm]
[ 75 ]
REMARKS
CEMLINE CWB SERIES; OPERATING
WT. 1500 LBS
EXISTING VIBRATION ISOLATION SCHEDULE
MIN STATIC
MARK
NECK SIZE
VI-1
VI-2
VI-3
VI-4
VI-5
LOCATION
ROOF
ROOF
ROOF
ROOF
ROOF
EQUIPMENT
AND/OR SERVICE
100-ACCH6A
100-ERP6A1&2
100-SCHP6A1&2
100-EF6A1&2
100-SF6A1&2
TYPE BASE
TYPE
ISOLATOR
IN
SS
DS
DS
SS
SS
1.22
NA
NA
[mm]
[ 31 ]
NA
NA
[ 25 ]
[ 25 ]
DEFLECTION NOTES
COMBINATION F/S. VERTICAL ORIENTATION
COMBINATION F/S. VERTICAL ORIENTATION
NECK SIZE
NC
DAMPER
NONE
NONE
NONE
NONE
NONE
NONE
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
OBD
FINISH
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
REMARKS
HUMIDIFICATION
B100 ROOF
GALPSI [kPa] PSI [kPa] PSI [kPa] PSI [kPa]
MARK[kg/HR]LBS/HR [kg/HR]LBS/HRIN WG [pa][M/s]
B100 ROOF
STEAM -
STEAM
SOFT WATER
PSIG [kPa]
CFM [L/s] CFM [L/s] IN WG [pa]
NC
CFM [L/s] CFM [L/s] IN WG [pa]
IN WG [pa] GALPSIG [kPa]
PIPE SIZE TO TANK
ENT CONTROL
VALVE
PRODUCED STEAM
FLOW
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E
T S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH004
MECHANICAL SCHEDULES
KEY PLAN
B B
C C
D D
A A
(E)6-232
VAV
6-229
AHU
(E)6-255
14x10
38x30 30x20
CAV
6-254
(E)6A-002
CAV
(E)6A-003
VAV
CAV
6-253
AHU
6-236
(E)6A-E001
AV
(E)6A-E003
AV
CAV
6-233
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E
T S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MD102
SECOND FLOOR DEMO HVAC
PLAN
SCALE:MD102 3/16" = 1'-0"
1 SECOND FLOOR HVAC DEMO PLAN
KEY NOTES:
SHEET NOTES:
1. FIELD VERIFY (E) CONDITIONS PRIOR TO
COMMENCEMENT OF WORK. NOTIFY ENGINEER OF ANY
DISCREPANCIES.
2. MECHANICAL CONTRACTOR SHALL COORDINATE WITH
VA COR TO SCHEDULE WORK WHICH MAY DISRUPT
BUILDING MECHANICAL SERVICES PRIOR TO
COMMENCEMENT OF ANY MECHANICAL DEMOLITION
WORK INDICATED ON THIS DRAWING.
3. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO
PROTECT ALL (E) BUILDING SERVICES, (E) BUILDING
STRUCTURE & ARCHITECTURAL ELEMENTS ETC. DURING
THE ENTIRE PERIOD OF MECHANICAL DEMOLITION
WORK. MAINTAIN MECHANICAL AND PLUMBING SERVICES
TO ALL AREAS OUTSIDE OF PROJECT BOUNDARY DURING
THE PERIOD OF CONSTRUCTION.
4. LOCATIONS OF EXISTING HVAC EQUIPMENT, DUCTS,
PIPING, ETC. ARE APPROXIMATE AND ARE INDICATED
FOR REFERENCE ONLY. EXACT LOCATIONS AND
ELEVATIONS SHALL BE VERIFIED IN THE FIELD AND
COORDINATED WITH OTHER NEW & EXISTING
EQUIPMENT/ SERVICES/ EXISTING BUILDING STRUCTURE
AND NEW WORK PLATFORM STEEL STRUCTURE.
5. CONTRACTOR SHALL FIELD VERIFY CONDITION AND
OPERATION OF ALL (E) & OFCI EQUIPMENT, CONTROLS,
VALVES, AND DEVICES, AND SHALL REPLACE ANY
FAULTY EQUIPMENT, CONTROLS, VALVES, AND DEVICES
WITH NEW.
6. DEMO ALL ACCESSORIES, HANGERS AND SUPPORTS
ASSOCIATED WITH DEMOLISHED DUCTWORK.
7. PERFORM PRE-CONSTRUCTION SUPPLY, RETURN AND
EXHAUST AIR MEASUREMENT OF ALL TERMINAL BOXES,
VOLUME DAMPERS, AND ASSOCIATED DIFFUSERS
SERVED BY AHU-6 AND EF-28. FINAL CONDITION TO
MATCH PRE-CONSTRUCTION AIRFLOW U.O.N. ON NEW
WORK PLAN.
8. TERMINAL UNIT RELOCATED. SEE MH102 FOR NEW
LOCATION. SEE MPD102 FOR HYDRONIC DEMO.
HYDRONIC PIPING TO BE RE-ROUTED.
(E) TERMINAL UNIT WITH PNEUMATIC CONTROLS1.
DEMO (E) DUCTWORK BETWEEN POINTS
SHOWN. RELOCATE TO LOCATION SHOWN ON
MH102 AND CONNECT TO NEW DUCTWORK.
2.
DEMO (E) AT CONNECTION TO TERMINAL UNIT.
PREPARE TERMINAL UNIT FOR CONNECTION TO
NEW DUCTWORK.
3.
DISCONNECT (E) TERMINAL UNIT, ASSOCIATED
CONTROLS AND PIPING APPUTENANCES AND
RELOCATE TO LOCATION SHOWN ON MH102.
4.
FD
FD
N
FD
S D
S D
S D
S D
S D
FD
FD
N
FD
ROOM AIR BALANCE SCHEDULE 100% OA
ROOM NO ROOM NAME
ROOM INFORMATION
SUPPLY UNOCCUPIED SUPPLY INFILTRATION EXFILTRATION EXHAUST UNOCCUPIED EXHAUST
ROOM AIR FLOW
ROOM AIR
BALANCE
DESIGN AC/hr
DESIGN OSA
AC/hr
UNOCCUPIED
AC/hr
NOTES
ROOM AIR ROOM AIR AIR AIR ROOM AIR ROOM AIR
Total Sq Ft Ceiling Height
Volume CFM CFM CFM CFM CFM CFM CAV VAV
E2-C32 CORRIDOR 577 9 5193 350 - 200 50 500 - X 0 + 4.0 4.0 4.0 50 CFM INFIL FROM E2-423, 50 CFM EXFIL TO E2-421
E2-C33 RESTRICTED CORRIDOR 311 9 2799 375
190 150 50 475 290 0 X 0 8.0 8.0
4.0
50 CFM INFIL FROM E2-422A, 50 CFM IN FROM E2-422B,
50 CFM INFIL FROM E2-424, 50 CFM EXFIL OUT TO E2-426
E2-C36 SEMI RESTRICTED CORRIDOR 522 9 4698 950 315 - 50 900 265 0 X 0 12.1 12.1 4.0 50 CFM EXFIL OUT TO E2-426
E2-422B HOLD / MONITOR 100 9 900 100 - - 50 50 - X 0 + 6.7 6.7 - 50 CFM EXFIL OUT TO E2-C33
E2-424 CLEAN SUPPLY 197 9 1773 120 - - 50 70 - X 0 + 4.1 4.1 - 50 CFM EXFIL OUT TO E2-C33
E2-432 TOILET 48 9 432 0 - 100 - 100 - X 0 -- 13.9 13.9 - 100 CFM INFIL FROM E2-426
E2-430 TOILET 48 9 432 0 - 100 - 100 - X 0 -- 13.9 13.9 - 100 CFM INFIL FROM E2-426
E2-425B HYBRID GENERATOR 90 9 810 965 - - - 965 - 0 0 0 71.5 71.5 -
E2-421 PUMP ANESTHESIA EQUIPMENT 100 9 900 100 - 50 - 150 - X 0 - 6.7 6.7 - 50 CFM INFIL FROM E2-423
E2-422A HOLD / MONITOR 100 9 900 100 - - 50 50 - X 0 + 6.7 6.7 - 50 CFM EXFIL OUT TO E2-C33
E2-426 LOCKERS 131 9 1179 330
- 100 200 230 - X 0 - 16.8 16.8 -
50 CFM INFIL FROM E2-C33, 50 CFM INFIL FROM E2-C36,
100 CFM EXFIL TO E2-432, 100 CFM EXFIL TO E2-430
E2-423 SCRUB 66 9 594 105 - - 50 55 - 0 X 0 10.6 10.6 - 50 CFM EXFIL TO E2-421
E2-427 HYBRID OR 907 10 9070 3200
1515 - 455 / 230 2720 1285 0 X + 21.2 21.2
10.0
305 CFM EXFIL TO E2-425A HYBRID CONTROL, 150 CFM
EXFIL TO E2-C32
E2-425A HYBRID CONTROL 158 9 1422 190 95 455 / 230 645 325 X 0 0 8.0 8.0 4.0 455 CFM INFIL FROM E2-427
B B
C C
D D
A A x3
38x30 30x20 x3 x3
20x18
16x12 (E)14x10 (E)
18x14 (E) x1
(E x1
(E x2
(E
16"ø (E) x1
(E
16"ø (E)
10"ø
8"ø
12"ø
10"ø (E)
10"ø
8"ø (E) 10x10 (E) x1
(E
8"ø x1
14"ø (E)
12"ø (2)
8"ø (E)
18x10
6"ø
12"ø
8"ø
20x12 x2
6-253
CAV
6-254
VAV
(E)6A-001
VAV
(E)6A-002
CAV
(E)6A-E004
AV
(E)6A-E001
AV
(E)6-258
VAV
(E)6-232
VAV
(E)6A-E003
AV
6A-E002
AV
(E)6-255
VAV
(E)6A-003
VAV
HYBRID OR
E2-427
ELEC
E-2-EC5
TEL/DATA
E2-TC5
(E) CORR
E2-C32
(E)
CORRIDOR
E2-C34
SEMI-RESTRICTED
CORRIDOR
E2-C36
CLEAN
SUPPLY
E2-424
HOLD/MONITOR
E2-422A
LOCKERS
E2-426
TOILET
E2-432
TOILET
E2-430
RESTRICTED
HALLWAY
E2-C33
HYBRID
CONTROL
E2-425A
PUMP/
ANESTHESIA
EQUIP
E2-421
HYBRID
GEN
E2-425B
"ø
10"ø
7"ø
16x14
7"ø
6"ø
16"ø
12"ø
16"ø 12"ø
14"ø
6-233
CAV
14"ø
6A-007
VAV
10"ø
12"ø
10"ø
8"ø
(E)
(E)6-236
VAV
x3
(E
(E)
10"ø (E) x1
(E
8"ø
8"ø
10"ø
12"ø
16"ø
10"ø
8" ø
12"ø
6"ø
6"ø
6"ø
6"ø
6"ø
CORR
E2-C21
B B
C C
D D
A A
HYBRID
CONTROL
E2-425A
HYBRID
GEN
E2-425B
HYBRID OR
E2-427
PUMP/
ANESTHESIA
EQUIP
E2-421
SCRUB
E2-423
HOLD/MONITOR
E2-422B
CLEAN
SUPPLY
E2-424
SEMI-RESTRICTED
CORRIDOR
E2-C36
LOCKERS
E2-426
TOILET
E2-432
(E) CORR
E2-C32
TEL/DATA
E2-TC5
ELEC
E-2-EC5
(E)
CORRIDOR
E2-C34
485ƒ
SD-14
480ƒ
SD-14
485ƒ
RG-25
480ƒ
RG-25
495ƒ
RG-26
190ƒ
SD-12
105ƒ
SD-11
55ƒ
RG-21
150ƒ
RG-21
100ƒ
SD-11
375ƒ
SD-13
230ƒ
RG-23
330ƒ
SD-13
100ƒ
RG-21
100ƒ
RG-21
70ƒ
RG-21
120ƒ
SD-11
100ƒ
SD-11
50ƒ
RG-21
950ƒ
SD-21
900ƒ
RG-26
680ƒ
32 x 14 RH
680ƒ
32 x 14 RH
680ƒ
32 x 14 RH
680ƒ
32 x 14 RH
100f
100f
50f
50f 50f
50ƒ
RG-21
100ƒ
SD-11
RESTRICTED
HALLWAY
E2-C33 475ƒ
RG-25
50f 50f
305ƒ
RG-26
305f
3200f FROM VAV-6A-001
TO INTEGRATED CEILING
(E) CORR
E2-C32
50f
350ƒ
SD-13
50f
T
T
T
T
T H
P 4
3150f
500ƒ
RG-26
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH102
SECOND FLOOR HVAC PLAN
KEY NOTES:
1. (N) 38x30 SA AND 38x30 EA DUCTWORK ENCLOSED IN (N) RATED SHAFT, MIN 80x36 ID CLEAR, UP. REFER TO
ARCHITECTURAL PLANS.
2. BOTTOM OF GRILLE 7" AFF.
3. SPACE PRESSURE DIFFERENTIAL SENSOR.
4. "BALL-IN-THE-WALL" FOR AIRFLOW DIRECTION VISUAL
VERIFICATION. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.
6. RELOCATED (E) THERMOSTAT SERVING VAV 6-208.
7. FSD SLEEVE EXTENDS TO 3RD FLOOR, SEE M103 FOR
ACCESS TO FSD'S.
8. SPACE PRESSURE DIFFERENTIAL MONITOR.
9. SPACE PRESSURE DIFFERENTIAL CONTROLLER.
10. VAV-254, VAV 6A-007, CAV-253, AV 6A-E002 REQUIRE
NEW POWER CONNECTION. FIELD TO VERIFY IF (E) VAV'S,
CAV'S, AV'S POWER REQUIRE NEW POWER CONNECTION.
11. CONNECT DUCT TO INTEGRATED CEILING PER
MANUFACTURER'S INSTRUCTIONS. PROVIDE ALL
TRANSITIONS AND OFFSETS AS NEEDED.
12. CAP (E) AIR VALVE AIR TIGHT. POINT OF CONNECTION
FOR FUTURE CATH LAB.
13. POINT OF CONNECTION FOR FUTURE CATH LAB.
SHEET NOTES:
1. FIELD VERIFY (E) CONDITIONS PRIOR TO
COMMENCEMENT OF WORK. NOTIFY ENGINEER OF ANY
DISCREPANCIES.
2. MECHANICAL CONTRACTOR SHALL COORDINATE WITH
VA FACILITY ENGINEER/ VA OFFICIAL REPRESENTATIVE
TO GET NECESSARY PERMIT TO ISOLATE (E) FUNCTIONAL
MECHANICAL SERVICES PRIOR TO COMMENCEMENT OF
ANY NEW WORK INDICATED ON THIS DRAWING.
3. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT
ALL (E) BUILDING SERVICES, (E) BUILDING STRUCTURE &
ARCHITECTURAL ELEMENTS ETC. DURING THE ENTIRE
PERIOD OF CONSTRUCTION.
4. LOCATIONS OF EXISTING EQUIPMENT, DUCTWORK,
PIPING, ETC. ARE APPROXIMATE AND ARE INDICATED
FOR REFERENCE ONLY. THE CONTRACTOR SHALL BE
RESPONSIBLE TO VERIFY AND COORDINATE EXACT
LOCATIONS AND ELEVATIONS IN THE FIELD.
5. COORDINATE WITH GENERAL CONTRACTOR FOR ANY
FLOOR / CEILING/ WALL/ ROOF PENETRATION OR CORE
DRILLING WORK, INCLUDING ANY WORK IN THE RISER
SHAFT SPACE ETC. NO WORK SHALL BE PERFORMED
WITHOUT APPROVAL FROM VA OFFICIALS/ VA FACILITY
ENGINEER/ GENERAL CONTRACTOR.
6. COORDINATE WITH G.C. FOR CEILING ACCESS TO CARRY
OUT ALL MECHANICAL/ PLUMBING WORK. COORDINATE
WITH G.C. TO PROVIDE ALL NEW CEILING ACCESS
PANELS THAT ARE NECESSARY FOR THE MAINTENANCE
& SERVICE OF THE NEW MECHANICAL EQUIPMENT AS
RECOMMENDED BY THE EQUIPMENT MANUFACTURERS.
7. COORDINATE EXACT LOCATIONS OF THERMOSTAT WITH
THE ARCHITECT BEFORE INSTALLATION.
8. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE
CEILING ACCESS PANELS TO ACCESS ALL VOLUME AND
MOTORIZED DAMPERS LOCATED OVER NON-ACCESSIBLE
CEILING.
9. PROVIDE REMOTE OPERATOR DAMPER WHERE CEILING
IS NON-ACCESSIBLE.
10. PROVIDE TRANSITIONAL DUCTWORK WHEREVER
REQUIRED TO CONNECT TO DUCT SIZES SHOWN IN THE
PLAN.
11. LOCATIONS OF NEW EQUIPMENT, DUCTWORK, PIPING,
ETC. ARE APPROXIMATE. CONTRACTOR SHALL INCLUDE
IN HIS BID ALL REQUIRED OFFSETS, TRANSITIONS,
FITTINGS, ETC. THAT ARE REQUIRED TO ROUTE THE NEW
DUCTWORK AND PIPING TO AVOID CONFLICTS WITH (E)
BUILDING STRUCTURE AND OTHER BUILDING SERVICES.
12. TAB CONTRACTOR TO REBALANCE ALL TERMINAL
BOXES, VOLUME DAMPERS, AND ASSOCIATED
DIFFUSERS SERVED BY AHU-6
13. PROVIDE MANUAL BALANCE DAMPERS ON ALL BRANCH
DUCT WORK SERVING A SINGLE DIFFUSER
SCALE:MH102 3/16" = 1'-0"
1 SECOND FLOOR HVAC NEW PLAN
SCALE:MH102 3/16" = 1'-0"
2 SECOND FLOOR HVAC AIR BALANCE PLAN
A A
B B
A A
B B
17 16 BB
A R
12x12
A
14x12
B B
17 16
17 16
BB
CC BB AA
16x16
12x10
12x12
8"
SECY/CLKS
E4-330
17 16
CC BB AA
17 16
A R
12x12
A
14x12
B B
17 16
16x16
12x10
12x12
8"
17 16
SECY/CLKS
E4-330
17 16
EQUIP
E3-333
EQUIP
E3-333
KEY NOTES:
1.
36x36 EA
2.
3.
4.
UL-LISTED 2-HR F/T FIRE WRAP THRU THIRD AND
FOURTH FLOORS. PROVIDE MIN 88X36 ID CLEAR.
INSTALL PER MANUFACTURER'S INSTRUCTIONS.
OFFSET (E) DUCT SECTION TO ALLOW FOR
INSTALLATION OF (N) SHAFT.
EXTEND FIRE WRAP 6 INCHES BEYOND SLAB AS
REQUIRED BY MANUFACTURER.
PROVIDE ACCESS DOOR TO SERVICE FSD'S.
36x36 SA
ROOF
38x30 EA
DN
M103
1 2
FOURTH FLOOR
38x30 EA
UP
38x30 SA
UP
1.
30x38 SA
2.
FIELD VERIFY (E) CONDITIONS PRIOR TO
COMMENCEMENT OF WORK. NOTIFY ENGINEER OF ANY
DISCREPANCIES.
THE CONTRACTOR SHALL COORDINATE WITH VA
FACILITY ENGINEER/ VA OFFICIAL REPRESENTATIVE
TO GET NECESSARY PERMIT TO ISOLATE (E)
FUNCTIONAL MECHANICAL SERVICES PRIOR TO
COMMENCEMENT OF ANY NEW WORK INDICATED ON
THIS DRAWING.
THIRD FLOOR HVAC PLAN
3/16" = 1'-0"
30x38 EA
4.
THIRD FLOOR 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO
PROTECT ALL (E) BUILDING SERVICES, (E) BUILDING
STRUCTURE & ARCHITECTURAL ELEMENTS ETC.
DURING THE ENTIRE PERIOD OF CONSTRUCTION.
LOCATIONS OF EXISTING EQUIPMENT, DUCTWORK,
PIPING ETC. ARE APPROXIMATE AND ARE INDICATED
FOR REFERENCE ONLY. THIS CONTRACTOR SHALL BE
RESPONSIBLE TO VERIFY AND COORDINATE EXACT
LOCATIONS AND ELEVATIONS IN THE FIELD.
5.
6.
SECOND FLOOR
COORDINATE WITH GENERAL CONTRACTOR FOR ANY
FLOOR/CEILING/WALL/ROOF PENETRATION OR CORE
DRILLING WORK, INCLUDING ANY WORK IN THE RISER
SHAFT SPACE ETC. NO WORK SHALL BE PERFORMED
WITH OUT APPROVAL FROM VA OFFCIALS/VA FACILITY
ENGINEER/GENERAL CONTRACTOR.
COORDINATE WITH G.C. FOR CEILING ACCESS TO
CARRY OUT ALL MECHANICAL/PLUMBING WORK.
COORDINATE WITH G.C. TO PROVIDE ALL NEW CEILING
ACCESS PANELS THAT ARE NECESSARY FOR THE
MAINTENANCE & SERVICE OF THE NEW MECHANICAL
EQUIPMENT AS RECOMMENDED BY THE EQUIPMENT
MANUFACTURERS.
7.
HVAC Section 3/16" = 1'-0"
8.
PROVIDE TRANSITIONAL DUCTWORK WHERE EVER
REQUIRED TO CONNECT TO DUCT SIZES SHOWN IN
THE PLAN.
LOCATIONS OF NEW EQUIPMENT, DUCTWORK, PIPING
ETC. ARE APPROXIMATE. CONTRACTOR SHALL
INCLUDE IN HIS BID ALL REQUIRED OFFSETS,
TRANSITIONS, FITTINGS ETC. THAT ARE REQUIRED TO
ROUTE THE NEW DUCTWORK AND PIPING TO AVOID
CONFLICTS WITH (E) BUILDING STRUCTURE AND
OTHER BUILDING SERVICES.
M103
38x30 SA
SHEET NOTES:
38x30 SA
DN
30x38 EA
SCHP
6A2
FOURTH FLOOR HVAC PLAN
3/16" = 1'-0"
HVAC Section #2 3/16" = 1'-0"
KEY PLAN
SCHP
6A1
ERP
ET
6A2
ERP
SSHX
6A
6A
CH
6A
ET
x E
A x S
A
1A
THIRD FLOOR HVAC DEMO PLAN
3/16" = 1'-0"
5.
PRIOR TO START OF CONSTRUCTION PERFORM
AIRFLOW READING AT SUPPLY DIFFUSER, PROVIDE A
COPY OF THE REPORT TO THE ARCHITECT FOR
REVIEW.
CAREFULLY REMOVE (E) DIFFUSER AND STORE FOR
RE-INSTALLATION IN NEW LOCATION IN NEW CEILING.
CLOSE MANUAL DAMPER SERVING DIFFUSER
6.
2A
FOURTH FLOOR HVAC DEMO PLAN
3/16" = 1'-0"
REMOVE (E) TERMINAL UNIT AND ASSOCIATED
CONTROLS, HHW PIPING & APPURTENANCES AND
PREPARE FOR RE-INSTALLATION IN NEW LOCATION.
DEMO (E) DUCT TO POINTS SHOWN AND PREPARE (E)
DIFFUSER FOR CONNECTION TO (N) DUCT.
7.
38x30 EA
6"
8"
30x38 FSD FOR EA & SA AT SHAFT WALL EXIT4
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH103
THIRD AND FOURTH FLOOR HVAC
PLANS
100-EF62
34"–
8"–, FB
8"– 8"–
100-EF65
100-EF63
O/A
28x26, FB
100-SA76
26x28
38x60 S F
PPD
SD5
48x48
50x60 40x38
AT WALL, TYP.
SUPPORT DUCT
72x72
100-AHU6
100-
SA12
S F
PPD
SD6
PPD
VD9
24x12
56x52
28x34
24x24
30"–
52x64
SHAFT
M2
12x12
100-SA13
48x60
PPD
SD7
PPD
16x16, FB
14"–
12"–
100-
SA43
EF26
100-
18"–, FB
VD8 36x12
100-EF27
10"–
14"–
48x72
S F
100-HPF6
16"– 16"–
100-
SA8
SUPPORT DUCT
AT WALL, TYP.
12"–M7 100-SA57
10"–
100-SA58
100-EF47
100-SA59
100-EF48
10"–
100-EF66
100-EF64
30"– 18"–
16"–, FB
O/A
100-EF53
8"–, FB
-A
H U
S A
-A
H U
-E
F
"– 1 -S
A
S A
A
B
C
B B
D D
C
B
A
16 15 14 13 12 11 10
1717 1616 1515 1414 1313 1212 1111 1010
KEY NOTES:
1.
2.
7.
8.
9.
10.
11.
12.
M103 36x36 SA (BELOW)
6A2
ERP
36x36 EA (ABOVE)
38x30 SA
SCHP
6A
ET
2 12.
13.
14.
15.
SCHP
6A1
6A2
(TYP.)
M103
9.
10.
11.
8.
7. LOCATIONS OF NEW EQUIPMENT, DUCTWORK, PIPING
ETC. ARE APPROXIMATE. CONTRACTOR SHALL INCLUDE
IN HIS BID ALL REQUIRED OFFSETS, TRANSITIONS,
FITTINGS ETC. THAT ARE REQUIRED TO ROUTE THE NEW
DUCTWORK AND PIPING TO AVOID CONFLICTS WITH (E)
BUILDING STRUCTURE AND OTHER BUILDING SERVICES.
ALL DUCTWORK RUNNING EXPOSED ON THE ROOF SHALL
BE SUPPORTED PER MECHANICAL DETAIL AS
APPLICABLE.
PROVIDE CONDENSATE DRAIN PIPING FOR ALL THE AIR
HANDLING UNITS PER MECHANICAL DETAIL.
PROVIDE PUMPS WITH VIBRATION ISOLATION BASE PER
DETAIL 1/M501 ON HOUSEKEEPING PAD.
CHILLER SHALL BE MOUNTED ON 2" DEFLECTION SPRING
ISOLATORS ATTACHED TO CONCRETE PADS.
AHU SHALL BE MOUNTED TO ROOF PER DETAIL 8/M502.
PROVIDE HOUSEKEEPING PAD FOR ALL PUMPS AND
HYDRONIC SPECIALTIES.
PROVIDE MAINTENANCE ACCESS ABOVE DUCT AS
REQUIRED.
SSHX-6A SHALL BE MOUNTED ON HOUSE KEEPING PAD.
6.
6A
CH
OA
4" SCHR
4.
4" SCH
6A
BT
5.
LOCATIONS OF EXISTING EQUIPMENT, DUCTWORK,
PIPING ETC. ARE APPROXIMATE AND ARE INDICATED FOR
REFERENCE ONLY. THIS CONTRACTOR SHALL BE
RESPONSIBLE TO VERIFY AND COORDINATE EXACT
LOCATIONS AND ELEVATIONS IN THE FIELD.
COORDINATE WITH GENERAL CONTRACTOR FOR ANY
FLOOR/CEILING/WALL/ROOF PENETRATION OR CORE
DRILLING WORK, INCLUDING ANY WORK IN THE RISER
SHAFT SPACE ETC. NO WORK SHALL BE PERFORMED
WITH OUT APPROVAL FROM VA OFFCIALS/VA FACILITY
ENGINEER/GENERAL CONTRACTOR.
PROVIDE TRANSITIONAL DUCTWORK WHERE EVER
REQUIRED TO CONNECT TO DUCT SIZES SHOWN IN THE
PLAN.
EA
AHU
6A
3. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT
ALL (E) BUILDING SERVICES, (E) BUILDING STRUCTURE &
ARCHITECTURAL ELEMENTS ETC. DURING THE ENTIRE
PERIOD OF CONSTRUCTION.
2" MPS
2" HEAT
RECOVERY
PIPING
2.
2-1/2" MPS DN
1. FIELD VERIFY (E) CONDITIONS PRIOR TO
COMMENCEMENT OF WORK. NOTIFY ENGINEER OF ANY
DISCREPANCIES.
THE CONTRACTOR SHALL COORDINATE WITH VA
FACILITY ENGINEER/ VA OFFICIAL REPRESENTATIVE TO
GET NECESSARY PERMIT TO ISOLATE (E) FUNCTIONAL
MECHANICAL SERVICES PRIOR TO COMMENCEMENT OF
ANY NEW WORK INDICATED ON THIS DRAWING.
SHEET NOTES:
1" MPR DN
ERP
AS
2" MPS
ERP
ET
SPRV
LPS
SSHX
6A 6A1
ERP
1" MPR DN
3.
4.
5.
6.
(N) SA AND (N) EA DUCTWORK ENCLOSED IN (N) RATED
SHAFT, MIN 88X36 ID CLEAR. PROVIDE ARCHITECTURAL
DOGHOUSE. REFER TO ARCHITECTURAL PLANS.
(E) CONDENSING UNIT. TO BE RELOCATED NIC. CONFIRM
WITH VA.
(E) TRAILER.
(N) MPR DOWN.
(N) STEAM PIPING UP FROM 4TH FLOOR.
(N) SCH AND SCHR UP FROM 4TH FLOOR. LOCATED
INSIDE VESTIBULE. SEE DETAIL 2/601 FOR BACK-UP SCH
CONNECTION.
CONFIRM LOCATION WITH VA.
NOT USED.
PROVIDE ELECTRICAL CLEARANCE BY CODE, 36" DEPTH.
VFD. SERVING SCHP-1 AND SCHP-2
SIZE PER MANUFACTURER'S RECOMMENDATION.
CNDS TO (E)CCD ON ROOF. REFER TO PLUMBING
DRAWINGS.
PARTIAL ROOF HVAC DEMO PLAN
1/8" = 1'-0"
(FOR REFERENCE ONLY)
ROOF HVAC PLAN
1/8" = 1'-0"
KEY PLAN
x E
A x S
A
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH105
ROOF HVAC PLAN
N
FD
FD
N
FD
N
FD
FD
N
FD
B B
C C
D D
A A
HOLD/MONITOR
E2-422B
HOLD/MONITOR
E2-422A
(E) CORR
E2-C32
SEMI-RESTRICTED
CORRIDOR
E2-C36
CLEAN
SUPPLY
E2-424LOCKERS
E2-426
TOILET
E2-432
RESTRICTED
HALLWAY
E2-C33
HYBRID
CONTROL
E2-425A
HYBRID
GEN
E2-425B
SCRUB
E2-423
PUMP/
ANESTHESIA
EQUIP
E2-421
HYBRID OR
E2-427
AHU-6
B B
C C
D D
A A
E2-426
LOCKERS
CAV-253
E2-424
CLEAN
SUPPLY
CAV-253
E2-C36
SEMI-RESTRICTED
CORRIDOR
VAV-251
E2-422A
HOLD/MONITOR
CAV-254
E2-422B
HOLD/MONITOR
CAV-254
E2-C33
RESTRICTED
HALLWAY
CAV-254
E2-432
TOILET
CAV-253
E2-421
PUMP/
ANESTHESIA
EQUIP
CAV-233
E2-423
SCRUB
CAV-233E2-425A
HYBRID
CONTROL
VAV-6A-003
E2-425B
HYBRID
GEN
VAV-6A-002
E2-427
HYBRID OR
VAV-6A-001
E2-C32
(E) CORR
CAV-233
CAV-233
CAV-253
CAV-254
VAV-6A-001
VAV-6A-002
VAV-6A-003
VAV-251
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH402
SECOND FLOOR HVAC ZONING
SCALE: NONEMH402
2 SECOND FLOOR AHU ZONING
SCALE: NONEMH402
1 SECOND FLOOR TU ZONING
N
FD
FD
N
FD
KEY PLAN
B B
C C
D D
A A
LOCKERS
E2-426 CLEAN
SUPPLY
E2-424
SEMI-RESTRICTED
CORRIDOR
E2-C36
VAV-6A-E002
HOLD/MONITOR
E2-422A
HOLD/MONITOR
E2-422B
RESTRICTED
HALLWAY
E2-C33
VAV-6A-E002
TOILET
E2-432
PUMP/
ANESTHESIA
EQUIP
E2-421
SCRUB
E2-423
HYBRID
CONTROL
E2-425A
VAV-6A-E003
HYBRID
GEN
E2-425B
HYBRID OR
E2-427
VAV-6A-E001
(E) CORR
E2-C32
VAV-6A-E001
VAV-6A-E002
VAV-6A-E003
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH403
EXHAUST AIR VALVE ZONING
JS DG
SCALE: NONEMH403
1 SECOND FLOOR EXHAUST AIR VALVE ZONING
FD
FD
N
FD
B B
C C
D D
A A
(E)6-255
VAV
(E)6A-E001
AV
(E)6-232
VAV
6-229
AHU
B B
C C
D D
A A
6-253
CAV
6-254
VAV
6-233
CAV
(E)6-236
VAV
(E)6A-001
VAV
(E)6A-002
CAV
(E)6A-E001
AV
(E)6A-E003
AV
6A-E002
AV
(E)6-255
VAV
(E)6A-003
VAV
CLEAN
SUPPLY
E2-424
LOCKERS
E2-426
TOILET
E2-432
TOILET
E2-430
RESTRICTED
HALLWAY
E2-C33
HOLD/MONITOR
E2-422A
(E) CORR
E2-C32
SEMI-RESTRICTED
CORRIDOR
E2-C36
PUMP/
ANESTHESIA
EQUIP
E2-421
SCRUB
E2-423
HYBRID
CONTROL
E2-425AHYBRID
GEN
E2-425B
HYBRID OR
E2-427
TEL/DATA
E2-TC5
ELEC
E-2-EC5
(E)
CORRIDOR
E2-C34
CORR
E2-C21
6-256
AHU
6-234
VAV
(E)6-258
VAV
(E)6-232
VAV
6-231
AHU
6-229
AHU
2 1/2" HHWSHHWS
2" HHWRHHWR
1" HHWRHHWR
1" HHWSHHWS
2" HHWSHHWS
2" HHWRHHWR
2" HHWSHHWS
2 1/2" HHWRHHWR
2" HHWSHHWS
1" HHWSHHWS
1" HHWRHHWR
2" HHWRHHWR
2" HHWSHHWS
2 1/2" HHWRHHWR
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MP102
SECOND FLOOR PIPING PLAN
SHEET NOTES:
1. HHWS / HHWR BRANCH PIPING TO TERMINAL UNITS ARE
3/4" DIAMETER UNLESS OTHERWISE NOTED.
SCALE:MP102 3/16" = 1'-0"
2 SECOND FLOOR HVAC PIPING DEMO PLAN
SCALE: NONEMP102
1 SECOND FLOOR HVAC PIPING NEW PLAN
DN
A A
B B
C C
12 11 10 9 8
DPT
3/4" 6"
2" 2"
2"
2"
2"
6" SCHR
6" SCH
1"
1"
2"
1" 6" SCH
6" SCHR
6" 2"
1"
2"
4"
6" MPS(30)
2"
1"
3/4" 2"
2"
12 11 10 9
S C
H R
S C
H
S G
S C
H
S G
S C
H R
KEY NOTES:
M103
1.
2.
3.
4.
5.
(N) SCHS/R PIPING, TAP INTO (E) SYSTEM
(N) MPS PIPING SERVING (N) 100-AHU6A
(N) 100-AHU6A LOCATED ON ROOF. REFER TO M105.
SCHS AND SCHR UP TO (N) 100-AHU6A.
(N) MPR PIPING.
SHEET NOTES:
1" MPR 1" MPR
2-1/2" MPS
2 4" SCH/R
PARTIAL FOURTH FLOOR PIPING PLAN
3/16" = 1'-0"
KEY PLAN
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MP104
FOURTH FLOOR PIPING PLAN
[1 m m
4" 8"
M
IN
SEALANT
[3 m m
[2 m m
PROVIDE ALUMINUM
JACKET
HIGH COMPRESSIVE
STRENGTH
INSULATION
INSERT UNDER SHIELD
WELD PIPE SADDLE
SUPPORT TO PIPE.
PROVIDE WATER
TIGHT CONNECTION
CLAMPING RING
PRE-MOULDED
FLEXIBLE PIPE
COUNTER FLASHING
ROOF SYSTEM
INSULATION AND
MEMBRANE
ROOF SURFACE
CONCRETE ROOF
SLAB
OR STEEL ROOF DECK
NOTES:
PROVIDE RESTRAINING CLAMPS 8'-0" [2438] O.C.
WELD PLATE
TO PIPE
8"x8"x3/8" [203x203x8.0mm]
STEEL PLATE
2-1/2" [65mm]
STEEL PIPE
2" [50mm]
STEEL PIPE
INSULATION
PROTECTION
SHIELD
PIPE AND
INSULATION
SECURE TO ROOF
SLAB
WITH (4) 3/8" [8.0mm]Ø
EXPANSION BOLTS OR
WELD TO STEEL DECK
5 FT
THRU [20]
6 8 10
[32][25] [40]
[65]
[50]
[75]
-1312 14 -16 -
[125][100]
[150]
[250]
[200]
[300]
[400]
[350]
[450]
[600]
[500]
20 241814 16128 1064 532 2 1/21 1/21 1 1/4
[9100] [9600][8500][7600] [8200][7000][5800] [6700][5200][4100] [4900][3700][3000] [3400][2700][2100]
--- --[4900] -[4100][3700] [4000] -[3000][2400][1800][1500]
THRU 3/4
[2100] [2100]
[2100]
[2700]
[2400]
1" M
A X
NOTES:
[2 5m m
[mm]
FT.
[mm]
FT.
[mm]
IN.
TUBING
PIPE
NOM. SIZE
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
MAXIMUM PIPE/TUBING SUPPORT SPACING
HANGER ROD
SADDLE
WELD
BAND
PROVIDE HIGH
COMPRESSIVE
STRENGTH
INSULATION (9 PSF MIN.
DENSITY) UNDER
INSULATION SHIELD
INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE
PIPE)
ADJUSTABLE CLEVISHANGER
TYPE 1 - SEE SPECIFICATIONS
PROVIDE INSULATION
SHIELD
& INSERT FOR ALL PIPING (8"
[200mm] MIN.)
SEE SPECIFER FOR
DETAILED HANGER
REQUIREMENTS
SIDE VIEW TRAPEZE HANGER FOR UP TO
1000 LB. [453KG] UNIFORM LOAD
1-5/8" [43mm] 12 GAUGE CHANNEL OR 2"x2"x1/4" [50x50x6.4mm] ANGLE
1/2" [15mm] DIA.
HANGER RODS WITH
36" [900mm] MAX.
SPACING ON EACH
CHANNEL
ADJUSTABLE CLEVIS HANGER
TYPE 43 - SEE SPECIFICATIONS
INSULATION SHIELD
AT HANGER
TURNBUCKLENUTS & WASHERS
FOR PIPES UNDER 2" [50mm] IN SIZE USE 1 1/2"x1 1/2"x1/4" [40x40x6.4mm] ANGLE.
ALL PIPES 2" [50mm] & LARGER USE 3"x3"x1/4" [75x75x6.4mm] ANGLE
3/8" [10mm] MIN
DIA HANGER
RODS
3/8" [10mm] MIN
DIA HANGER
RODS
3/8" [10mm] MIN
DIA INSERTS NEW
CONSTRUCTION
ONLY.
3/8" [10mm] MIN DIA EXPANSION
BOLTS FOR EXISTING CONSTRUCTION
AND INSERTS FOR NEW
CONSTRUCTION
STEEL EXPANSION SHIELD FOR EXISTING
CONSTRUCTION AND INSERTS FOR NEW
CONSTRICTION THIS TYPE SHALL BE
USED ONLY IN SLABS OR BEAMS OF 4"
[100mm] MIN DEPTH
CONCRETE
FLOOR
SLAB
CLIP
ANGLE
2D
16"
5D
1"
D
5D
W
L
L/
L/
[2 5m m
5" M
IN
[1 m m
5" M
IN
[1 m m
[400mm]
B B
A
A
FLOOR
EQUIPMENT BASE PLATE
PLAN
SECTION A-A (BASE NOT POURED WITH SLAB)
PROVIDE #3 BARS 12" [300mm]
O.C. EACH WAY IN THE BASE &
DOWEL BASE TO FLOOR
TYPICAL ANCHOR
BOLT NUT &
WASHER
SECTION A-A (BASE POURED WITH FLOOR SLAB)
PROVIDE DOUBLE SLAB
REINFORCING IN BASE
AREA
TYPICAL ANCHOR
BOLT NUT &
WASHER
CONCRETE BASE
SECTION B-B
WELD HEAD TO PLATE
OR BEND OVER END
5D
EQUIPMENT BASE PLATE
ANCHOR
BOLT
(TYP)
PIPE SLEEVE (5D,
3" [75mm] MIN.)
NOTE:
L & W DIMENSIONS
SHALL BE 6" [150mm]
GREATER THAN THE
EQUIPMENT BASE
PLATE.
NOTE:
FINAL ANCHORAGE DESIGN AND DETAILING TO BE PROVIDED BY
CONTRACTOR PER SPEC SECTION 13 05 41.
DRIVEN
EQUIPMENT
MOTORSHAFT
MOTORSHAFT
DRIVEN
EQUIPMENT
A
A
SLEEVE REINFORCING BARS
TYPICAL
STRUCTURAL
STEEL MEMBER FOR
EQUIPMENT
NUMBER OF
ISOLATION
UNITS AS REQUIRED
TYPICAL
STRUCTURAL
STEEL MEMBER FOR
EQUIPMENT
STRUCTURAL
STEEL
FRAME
ANCHOR
BOLT
SPRING
ISOLATO
R
ALL WELDED
STEEL
FRAMEWORK
NUMBER OF
ISOLATION
UNITS AS REQUIRED
TYPE "1"
CONCRETE INERTIA
BASE
SECTION A-A
TYPE "B"
WELDED STEEL
BASE
RISER
CLAMP
PLAN
ELEVATION
PIPE
SLEEVE
WHERE
SPECIFIED
RISER
RISER
CLAMP
PIPE SLEEVE
WHERE SPECIFIED PIPE
BOLT
FIRE-STOPPING
MATERIAL
FLOOR
SLAB
BOLT
(TYPICAL)
INSULATION
EXTEND SLEEVE ABOVE
FLOOR WHERE SPECIFIED.
NOTES:
1.
2.
RISER CLAMP.
BOTTOM CLAMP
REQUIRED AT
ANCHOR POINTS
ONLY.
PROVIDE ANCHORS ONLY
WHERE SHOWN ON
DRAWINGS.
PIPE ANCHOR
SCHEDULE
D P C N S BOLT PATTERN
D=PIPE O.D.
D+3 3/4"
D+1 1/2"
5/16" P
D
C
D+2 1/2"
D+4 3/4"
D+[25]
MMINMMMMMMMM
[8]
D+1"
D+[38]
D+[95]
D+[64]
D+[121]
ININININ
16 19 19
102102
4"
4"
4"
1 1
2"
2 1
"4"1 "1
3"
"4"3
"5
"4"
NOTE:
A. WHERE USED FOR COPPER TUBE OR PIPE,
BRAZE TO FABRICATED STEEL ANCHOR
ANCHOR BOLTS
N=NUMBER
S=SIZE
DRILL Ø = S+
1/16"
DRILL Ø = S+[2]
INSULATE AS INDICATED FOR ALL
CHILLED WATER. INSULATE PIPE
ONLY FOR STEAM & CONDENSATE
STL PIPE OR
COPPER
TUBE
NOTE A
STEAM TRAP ASSEMBLY
STEAM LINE DRIP POCKET
6"
2"
6"
2"
CAP (TYPICAL)
[3 m m
M
IN
[1 m m
M
IN
[3 m m
M
IN
[1 m m
M
IN
3/8" [10mm]
TEST
CONNECTION
DRIP
RETURN
NOTE:
DRIP POCKET PIPE SIZE
SAME AS STEAM MAIN
UNLESS OTHERWISE
NOTED.
3/4" [20mm] MIN.
FROM DRIP
CONNECTIO
N
3/4" [20mm] DRAIN
(ALTERNATE
LOCATIONS)
(TYPICAL)
PIPE T0 STEAM
TRAP
(TYPICAL)
STEAM LINE
(TYPICAL)
DRIP LEG (TYP.)
D
1" M
IN
24" MAX.
3"
1.
2.
3.
4.
[76mm]
[610mm]
[2 5m m
OPEN DRAIN (NOTE 3)
SAFETY VALVE
DO NOT CONNECT ANY OTHER DRAIN TO THE DRIP PAN ELBOW DRAIN PIPE.
DISCHARGE OF DRAIN MUST BE DIRECTED AWAY FROM PLATFORMS OR OTHER AREAS
WHICH PERSONNEL MAY OCCUPY.
VENT PIPE SHALL TERMINATE 6' [1829mm] MIN. ABOVE FINISHED ROOF.
UNLESS OTHERWISE SHOWN ON THE DRAWINGS, SIZE THE VENT PIPE SO THAT STEAM
IS NOT BLOWN OUT AT THE VENT PIPE ENTRANCE. UTILIZE THE CALCULATION METHOD
CONTAINED IN ANSI B31.1. POWER PIPING CODE, APPENDIX II.
NOTES:
3/4" [20mm] DRAIN
TO FLOOR DRAIN OR
OPEN SIGHT DRAIN
(NOTE 4)
ELEVATION
FLEXIBLE
CONNECTOR
CONNECTION TO PRESSURE
VESSEL OR PIPE
DRIP PAN ELBOW
(SECTIONAL VIEW)
PIPE THREADED INTO ELBOW
(SAME SIZE AS ELBOW)
VENT PIPE THROUGH ROOF
SUPPORT AS INDICATED ON
DWGS. (NOTES 1, 2)
PROVIDE UNION UNLESS SAFETY
VALVE HAS FLANGED OUTLET
1. VENT ALL HIGH POINTS INDICATED ABOVE.
2. IF AUTOMATIC AIR VENTS ARE USED, PIPE DISCHARGE TO
DRAIN.
NOTES:
TYPICAL MANUAL AIR VENT
ELEVATION
CIRCULATING WATER PIPING
1/2" [15mm] x 4" [100mm]
NIPPLE
1/4" [8mm]
COPPER
TUBING
MV
OR
AV
AIR VENT
1/2" [15mm]
BALL
VALVE
2. WHERE SCALE POCKETS ARE SHOWN ON PIPE RISER
DIAGRAMS
AND/OR PLANS LOCATE DRAIN AT BOTTOM OF SCALE POCKET.
1. DRAIN ALL LOW POINTS AS INDICATED ABOVE.
NOTES:
PIPING DRAIN VALVE CONNECTIONS
TYPICAL CHILLED AND HOT WATER
ELEVATION
THREADED
PIPING
ELEVATION
WELDED
PIPING
ADAPTER TO 3/4" [20mm] HOSE
THREAD-PROVIDE HOSE CAP
NUT
3/4" [20mm] BALL VALVE
REDUCER, IF REQUIRED
TYPICAL WATER PIPING
A B
1"
[2 5m m
FLOOR SINK
CLEAN OUT
WHERE X = STATIC PRESSURE IN PAN
BAUNIT TYPE
2X
X
1" [25mm]
MINIMUM
2" [50mm]
PLUS X
BLOW THRU
DRAW THRU
NOTE:
1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY
LOCAL VA AND IS INDOORS AND DOES NOT PASS
THROUGH
RATED BARRIERS.
2. DIELECTRIC FITTING TO BE USED WHEN TWO
DISSIMILAR
METALS ARE TO BE CONNECTED.
DRAIN LINE SHALL BE AT LEAST THE SAME
SIZE AS THE NIPPLE ON THE DRAIN PAN
PIPING SHALL BE RIGID COPPER TYPE L
OR
TYPE M UNLESS NOTE BELOW IS MET
PITCH DOWN
TOWARD
DRAIN
DIELECTRIC
FITTING
DRAIN
PAN
D
D
MV
PINC
BLADDER
EXPANSION
TANK
DRAIN
DRAIN
6"
NOTE:
1.
2.
3.
ROOF MOUNTING BASE RING
WITH DRAIN ACCESS OPENING
SHOWN. ANGLE IRON LEGS
MAY BE USED AS AN OPTION.
[150mm]
HOUSEKEEPING
PAD FROM SYSTEM
RUN DRAIN LINE TO
NEAREST FD UNLESS
INDICATED OTHERWISE
AIR CHARGING
SHRAEDER VALVE
COLD WATER FILL LINE.
SEE EXPANSION TANK
SCHEDULE FOR SIZE
RUN DRAIN
LINE TO
NEAREST FD
REDUCED PRESSURE BACKFLOW
PREVENTER
SET PRESSURE REDUCING
VALVE SO PRESSURE AT
HIGHEST POINT IN SYSTEM
HAS A MINIMUM OF 4 PSIG
[28kPa].
FOR HOT WATER SYSTEMS 2"
[50mm] AND SMALLER AND
CHILLED WATER SYSTEMS USE
IN-LINE AIR PURGER IN LIEU
OF AIR SEPARATOR.
SEE EXPANSION TANK SYSTEM
SCHEDULE FOR COMPONENT
SIZES.
AIR
SEPARATOR
SEE NOTES
3 & 4
BUTTERFLY
OR BALL
ISOLATION
VALVE
TO PUMP
SUCTION
HANGER
RODS (TYP)
CONNECTOR PIPE.
AUTO. AIR VENT TO DRAIN
M 24700
STAT E OF CALIFORNIA
RE
E
NI
GN
E
LANOISSEFORP
DERET
SI
G E
R
S R
EYM.AEHP
E T
S
EXPIRES 3/31/21
MECHAN ICA L
DATE SIGNED:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MECHANICAL:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street
Concourse Federal Group
100% BID SET VAPAHCS Cath Lab Suite Upgrade
640-13-134
3801 Miranda Avenue, Palo Alto, CA
07/10/2020
Capital Consulting Engineers
Bryan Johnson, PE
(916) 851-3500
Rancho Cordova, California 95670
11020 Sun Center Drive, Suite 100
06/02/20
MH501
MECHANICAL DETAILS
SCALE: NONEMH501
6 DETAIL FOR SUPPORTING PIPE ON ROOF
SCALE: NONEMH501
5 PIPE HANGERS
SCALE: NONEMH501
3 SECURING HANGER RODS IN CONCRETE
SCALE: NONEMH501
2 CONCRETE EQUIPMENT BASES
SCALE: NONEMH501
1 VIBRATION ISOLATION BASES
SCALE: NONEMH501
4 SUPPORT ANCHOR FOR PIPE RISERS
SCALE: NONEMH501
7 SMALL PIPE ANCHOR
SCALE: NONEMH501
8 STEAM LINE DRIP POCKET STEAM TRAP ASSEMBLY
SCALE: NONEMH501
9 STEAM SAFETY VALVE
SCALE: NONEMH501
DRAIN VALVE AND AIR VENT CONNECTIONS
(HYDRONIC SYSTEMS)
SCALE: NONEMH501
12 AIR HANDLING UNIT DRAIN TRAP DETAIL
SCALE: NONEMH501
ROOF-MOUNTED EXPANSION TANK
PIPING CONNECTIONS
CHECK VALVE
FLOOR
PUMP
FLEXIBLE CONNECTOR (TYPICAL)
1/2" [15mm]
NOTES:
1. SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION.
VIBRATION
ISOLATOR (TYPICAL)
INSTALL HANGER AS CLOSE
TO PIPE ELBOW AS
POSSIBLE (TYPICAL)
RIGID PIPE
HANGER
FIRST 3 HANGERS FOR EACH PIPE
AND BRANCH SHALL BE SPRING &
NEOPRENE TYPE. TYPE "H" FOR 4"
[100mm] DIA. PIPE & SMALLER. TYPE "H-P" FOR 5" [125mm] DIA. PIPE &
LARGER.
RIGID PIPE
HANGER
BUTTERFLY OR BALL
SHUT OFF VALVE, TYP.
OPTIONAL STRAINER
PRESSURE GAUGE
1/2" [15mm]
SUCTION DIFFUSER
WITH BUILT IN STRAINER.
OPTIONAL: LONG RADIUS
ELBOW AND INLET STRAINER
WITH 3XDIAM STRAIGHT
INLET TO PUMP
DRAIN
1" [25mm] MIN.
DIA. PIPE STAND
CONCRETE
INERTIA BASE
2. FINAL ANCHORAGE DESIGN AND DETAILING TO BE PROVIDED BY
CONTRACTOR PER SPEC SECTION 13 05 41.
V
4 D2 MIN.
20 D2 MIN.10 D1 MIN.
D2
N.C.
D1
1.
2.
3.
4. PROVIDE NECESSARY UNIONS FOR THE REMOVAL OF VALVE WITH SCREWED
CONNECTIONS.
MAKE BYPASS VALVE DISCHARGE PIPE THE SAME SIZE AS D2 FOR THE LARGEST
PRV.
SEE EQUIPMENT SCHEDULES FOR VALVE DATA AND PIPE SIZES D1 AND D2.
INSTALL VALVES AS RECOMMENDED BY MANUFACTURER.
SEE FLOOR PLANS FOR PIPE SIZES.
NOTE:
INVERTER
BUCKET TRAP
ASSEMBLY
TYP.
SIPHON
(TYP.)
NOTE 1
PSV
NOTE 3
VENT TO ATMOSPHERE
PILOT CONTROL LINE
REDUCER
(TYP.)
IF REQUIRED.
NOTE 1
MV
MODULATION CONTROL VALVE
SHUT OFF VALVE
WATER SUPPLY
MANUAL AIR VENT
WATER RETURN
REDUCER, IF REQUIRED
TEST PLUG (TYP.)
COIL
DRAIN WITH HOSE
CONNECTION
UNION
CONNECTIONS
(TYP.)
BALANCING VALVE
FLOW
M
IN
6"
M
IN
[3 m m
[1 m m
1.
2. PROVIDE BYPASS PIPING.
ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 12" MINIMUM HIGH
DRIP LEG FROM BOTTOM OF STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 6"
SCALE POCKET BELOW TRAP INLET.
NOTE:
SEE DRAWINGS FOR PIPE SIZES
SCHEDULE 80 STEEL PIPE
TO RETURN MAIN
PIPE SIZE SHALL BE SAME SIZE
AS TRAP
BYPASS-INSTALL IN HORIZONTAL
PLANE LEVEL WITH TRAP OR IN
VERTICAL PLANE & BELOW TRAP
DRIP LEG OR EQUIPMENT
CONNECTION. MAKE THE SAME
SIZE AS THE SUPPLY MAIN OR
EQUIPMENT CONNECTION. SEE NOTE 1
INVERTED BUCKET TRAP.
SEE PLANS, AND
SCHEDULES
DIELECTRIC FITTING
WHERE RETURN IS
COPPER PIPE
1" GATE VALVE
SCHEDULE 80
STEEL PIPE
T O
P U
M P
S U
C T
IO
N
F R
O M
P U
M P
D
IS
C H
A R
G E
1" [25mm]
NOTE:
TOP OF CHEMICAL POT
FEEDER TANK SHALL NOT BE
MORE THAN 4'-0" [1200mm]
ABOVE FINISHED FLOOR.
TO
DRAIN
1" [25mm]
CHEMICAL POT
FEEDER-
MINIMUM CAPACITY
GALLONS [19L]
AUTOMATIC
FLOW
CONTROL AND
BALANCE DEVICE
FUNNEL
3/4" [20mm]
50"
NOTE:
TABULATED DATA FROM SMACNA
ALLOWS FOR DUCT REINFORCING
AND INSULATION,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .