S02 - Construction Documents Bid Set 2 - DRAFT.pdf

PDF 16 MB Posted

Attached to
Z1DA--640-13-134 PAD Hybrid Cath Lab OR Upgrades
Solicitation number
36C26121R0079
Issued by

About this file

This notice announces an upcoming federal contract opportunity for construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 plans to issue a Request for Proposal to complete construction of a new Catheterization Laboratory Hybrid Operating Room Suite and install a rooftop air handling unit at the VA Palo Alto Health Care System campus in Palo Alto, California. The construction period is 365 days with a projected value between $5 million and $10 million. The NAICS code for this project is 236220. Offerors must register in the System for Award Management and have a current Online Representations and Certifications Application on file by the solicitation due date and time of award. Eligible small businesses include verified Service-Disabled Veteran-Owned and Veteran-Owned Small Businesses. The solicitation is anticipated for issue after November 4, 2021.

View the file

Other files

File Type Posted
C01 - Award Notice - 36C26122C0022.pdf PDF
S06 - 36C26121R0079 - Amendment 0009.pdf PDF
S06 - 36C26121R0079 - 0009 - RFI 5 - Reissued AS601 for Correct Door Hardware Sets.pdf PDF
S06 - 36C26121R0079 - Amendment 0008.pdf PDF
S06 - 36C26121R0079 - Amendment 0007 - 2nd site visit sign-in.pdf PDF
S06 - 36C26121R0079 - Amendment 0007.pdf PDF
S06 - 36C26121R0079 - Amendment 0006.pdf PDF
S06 - 36C26121R0079 - Amendment 0006 - RFI 3 - 140602 Cath Lab Lead Shielding Modification Certification.pdf PDF
S06 - 36C26121R0079 - Amendment 0006 - RFI 3 - 140530 Lead Shielding Protective Barrier Recommendations.pdf PDF
S06 - 36C26121R0079 - Amendment 0005.docx DOCX document
S06 - 36C26121R0079 - Amendment 0004.docx DOCX document
S06 - 36C26121R0079 - Amendment 0003.docx DOCX document
S06 - 36C26121R0079 - Amendment 0003 - site visit sign-in sheet - 11-30-2021.pdf PDF
S06 - 36C26121R0079 - Amendment 0002.docx DOCX document
S06 - 36C26121R0079 - Amendment 0001.docx DOCX document
Cath Lab Spec Vol 1 2021_0423_.pdf PDF
RFP Presentation_VAPA Cath_211130.pdf PDF
640-13-134 Bid Set combined_.pdf PDF
Cath Lab Spec Vol 2 2021_0423_.pdf PDF
S02 - Exhibit A - QC Section 014500.pdf PDF
S02 - Exhibit B - QC Plan Review Checklist.pdf PDF
Factor 2 - Key Personnel Qualifications Resumes.xlsx XLSX spreadsheet
Factor 5 - Attachment B - Past Performance Questionnaire.docx DOCX document
S02 - Government Furnished Property List.pdf PDF
S02 - Large Business Subcontracting Plan Template.docx DOCX document
S02 - Small Business Participation Plan Template.docx DOCX document
Factor 5 - Attachment D - Sample Client Authorization Letter.docx DOCX document
Factor 5 - Attachment C - Consent Letter.docx DOCX document
S02 - DOL Wage Determination - CA20210018 - 10292021 - Santa Clara County.pdf PDF
Factor 1 - Prime Contractor Project Experience.xlsx XLSX spreadsheet
S02 - Solicitation 36C26121R0079 - FINAL.docx DOCX document
S02 - Name Brand Requirements List.pdf PDF
S02 - Request for Information (RFI) Form - 36C26121R0079.docx DOCX document
S02 - Construction Documents Bid Set 3 - DRAFT.pdf PDF
S02 - Cath Lab Spec Vol 1 20210115 - DRAFT.pdf PDF
S02 - Cath Lab Spec Vol 2 20210115 - DRAFT.pdf PDF
S02 - Construction Documents Bid Set 1 - DRAFT.pdf PDF
36C26121R0079_2.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A

B B

C C

D D

E E

F F

17 16 15 14 13 12

17 16 15 14 13 12

4 WS-1

KEY NOTES:

1 3/4" CW UP THRU ROOF, PROVIDE RPZ BACKFLOW

PREVENTER ASSEMBLY WITH SUPPORTS ON ROOF &

EXTEND TO CONDENSATE COOLER AND CONNECT

AS REQUIRED. PROVIDE AIR GAP FITTING AND 2"

DRAIN TO NEAREST ROOF DRAIN.

2 1 1/4" CW UP THRU ROOF, PROVIDE RPZ BACKFLOW

PREVENTER ASSEMBLY WITH SUPPORTS ONB ROOF

& EXTEND TO NEW WATER SOFTENER MOUNTED ON

ROOF AND CONNECT AS REQUIRED. PROVIDE AIR

GAP FITTING AND 2" DRAIN TO NEAREST ROOF

DRAIN.

3 EXISTING ROOF DRAINS NEXT EXISTING RTU TO

REMAIN. CONDENSATE FROM NEW RTU TO BE

EXTENDED TO EXISTING ROOF DRAINS BY

MECHANICAL CONTRACTOR. DRAINS FROM ROOF

MOUNTED RPZ'S & WATER SOFTENER TO BE

EXTENDED TO EXISTING ROOF DRAINS BY PLUMBING

CONTRACTOR.

4 NEW WATER SOFTENER, MOUNT ON PAD ON ROOF &

SECURE TO STRUCTURAL FRAME ATTACHED TO PAD

& MOUNT RESIN TANK HEAD COVER SECURELY TO

FRAME. CONNECT CW SUPPLY AND INTERCONNECT

TANKS IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS. EXTEND DISCHARGE OF WATER

SOFTENER TO NEW HUMIDIFIER AND CONNECT AS

REQUIRED. EXTEND DRAIN FROM SYSTEM TO

NEAREST ROOF DRAIN. COORDINATE EXACT

LOCATIONS AND CONNECTION POINTS WITH

MECHANICAL CONTRACTOR.

5 EXISTING VENT THROUGH ROOF TO REMAIN. VENT IS

GREATER THAN 25' FROM OUTSIDE AIR INTAKES OF

NEW AND EXISTING RTU'S

6 EXSITING SANITARY VENTS THROUGH THE ROOF.

VENTS TO BE RELOCATED IN CEILING BELOW TO

NEW LOCATION ADJACENT TO EXHAUST FAN

DISCHARGES AS REQUIRED TO BE GREATER THAN

25' FROM OUTSIDE AIR INTAKES. COORDINATE

ROUTING OF VENT PIPING IN CEILING BELOW WITH

EXISTING PIPING & OTHER TRADES. COORDINATE

NEW ROOF VENT PENETRATIONS WITH EXISTING

EXHAUST FANS.

7 MAINTAIN EXISTING CLEARANCE IN FRONT OF FIRE

PROTECTION ROOF MANIFOLD.

SHEET NOTES:

1. CONSTRUCTION TO BE PERFORMED IN PHASES.

COORDINATE ALL WORK WITH G.C. TO PERFORMED IN

CORRECT PHASE AND TO ALLOW FOR CONTINUATION OF

SERVICES IN NON-CONSTRUCTION AREAS AS REQUIRED.

2. ALL SHUT-DOWNS AND CHNAGE-OVERS SHALL BE

PERFORMED DURING PREMIUM TIME HOURS AS DIRECTED

BY THE OWNER TO MINIMIZE DONWTIME AND DISRUPTION

TO FACILITY SERVICES TO OTHER NON-CONSTRUCTION

AREAS. COORDINATE ALL SHUT-DOWNS AND CHANGE-

OVERS WITH OWNER/G.C.

3. ALL REMOVED FIXTURES OR EQUIPMENT AND

ASSOCIATED PIPING, HANGER, INSULATION, SUPPORTS,

ETC. SHALL REMOVED FROM SITE. CAP ALL UNUSED

SERVICES AT NEAREST ACTIVE MAINS OR BRANCH LINES

AS CLOSELY AS POSSIBLE TO ELIMINATE ALL DEAD END

PIPING.

4. COORDINATE ROUTING OF ALL PIPING WITH NEW AND

EXISTING STRUCTURAL CONDITIONS AND WITH OTHER

TRADES WORK, BOTH NEW AND EXISTING.

5. ALL RISERS SERVING OTHER FLOORS SHALL REMAIN

ACTIVE. RISERS PASSING THROUGH AREAS OF WORK

SHALL BE REROUTED AS REQUIRED TO PROVIDE

CONTINUED SERVICE WITH AS LITTLE DISRUPTION AS

POSSIBLE. COORDINATE EXACT LOCATION OF REROUTED

RISERS IN FIELD WITH G.C. AND INSTALL ALL NEW PIPING

FOR PREPARATION OF CHANGE-OVER RPIOR TO ANY

DISCONNECTION OF SERVICES. CHANGE-OVER SHALL BE

AS DIRECTED BY THE OWNER TO MINIMIZE DISRUPTION TO

OTHER AREAS OF THE FACILITY.

M 24700

STAT E OF CALIFORNIA

RE

E

NI

GN

E

LANOISSEFORP

DERET

SI

G E

R

S R

EYM.AEHP

E T

S

EXPIRES 3/31/21

MECHAN ICA L

DATE SIGNED:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

MECHANICAL:

Gene Klow, AIA

(855) 521-1110

Alexandria, Virginia 22314

123 S Royal Street

Concourse Federal Group

100% BID SET VAPAHCS Cath Lab Suite Upgrade

640-13-134

3801 Miranda Avenue, Palo Alto, CA

07/10/2020

Capital Consulting Engineers

Bryan Johnson, PE

(916) 851-3500

Rancho Cordova, California 95670

11020 Sun Center Drive, Suite 100

06/02/20

PL105

ROOF PLUMBING PLAN

SCALE: NONEPL105

1 ROOF PLUMBING PLAN

Revisions: Date:

KEY PLAN

N

FD

FD

N

FD

B B

C C

D D

A A

HYBRID

GEN

E2-425B

PUMP/

ANESTHESIA

EQUIP

E2-421

CLEAN

SUPPLY

E2-424

LOCKERS

E2-426

(E) CORR

E2-C32

ELEC

E-2-EC5

(E)

CORRIDOR

E2-C34

RESTRICTED

HALLWAY

E2-C33

(E) CORR

E2-C32

TOILET

E2-432

TOILET

E2-430

HOLD/MONITOR

E2-422A

SCRUB

E2-423

HYBRID

CONTROL

E2-425A

HYBRID OR

E2-427

SEMI-RESTRICTED

CORRIDOR

E2-C36

C2

C5

C1

C3

C4

B1

(E) CORR

E2-C32

1/2" O (E)(E)

3/4" MV (E)(E)

1/2" MA (E)(E)

1/2" O?

3/4" MV?

1/2" MA?

1/2" CO2 (E)(E)

1/2" O (E)(E)

1/2" MA (E)(E)1 1/4" MV (E)(E)

1" N (E)(E) 1/2" N2O (E)(E)

C6 6

3/4" CO2

1" MV

3/4" MA

3/4" O

1/2" N2O

1" MV

1/2" MA

1/2" O

EXISTING

1" N LOOP &

CONTROL PANEL

TO REMAIN

A

B

D

D

B

A

1/2" N

1/2" MV

1/2" O

1/2" MA

3/4" MV

1/2" CO2

1/2" CO2

1/2" O

1/2" MA

1/2" MV

1/2" N

1/2" N2O

1/2" O

1/2" MA

1/2" CO2

TEL/DATA

E2-TC5

CORR

E2-C21

(E) CORR

E2-C32

TECH

OFFICE

E2-411

ADMIN

OFFICE

E2-329

RESIDENCY

PROG

DIRECTOR

E2-331

ORAL

SURGERY

OFFICE

E2-333

OFFICE

E2-429

OFFICE

E2-431

OFFICE

E2-433

OFFICE

E2-435

CHIEF

OFFICE

E2-437

1" N

1/2" MV

1/2" WAGD

1/2" WAGD

81/2" WAGD

B B

C C

D D

A A

CHIEF

OFFICE

E2-437

OFFICE

E2-435

OFFICE

E2-433

(E)

CORRIDOR

E2-C34

SEMI-RESTRICTED

CORRIDOR

E2-C36

LOCKERS

E2-426

TOILET

E2-432

CLEAN

SUPPLY

E2-424

HOLD/MONITOR

E2-422A

HOLD/MONITOR

E2-422B (E) CORR

E2-C32

RESTRICTED

HALLWAY

E2-C33

HYBRID

CONTROL

E2-425A

PUMP/

ANESTHESIA

EQUIP

E2-421

SCRUB

E2-423HYBRID

GEN

E2-425B

HYBRID OR

E2-427

TEL/DATA

E2-TC5

ELEC

E-2-EC5

(E) CORR

E2-C32

TOILET

E2-430

EXISTING:

1/2" CO2

1/2" O

1/2" MA

1-1/4" MV

1" N 1/2" N2O

EXISTING

1" N LOOP &

CONTROL

PANEL TO

REMAIN

EXISTING 1" N

M 24700

STAT E OF CALIFORNIA

RE

E

NI

GN

E

LANOISSEFORP

DERET

SI

G E

R

S R

EYM.AEHP

E T

S

EXPIRES 3/31/21

MECHAN ICA L

DATE SIGNED:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

MECHANICAL:

Gene Klow, AIA

(855) 521-1110

Alexandria, Virginia 22314

123 S Royal Street

Concourse Federal Group

100% BID SET VAPAHCS Cath Lab Suite Upgrade

640-13-134

3801 Miranda Avenue, Palo Alto, CA

07/10/2020

Capital Consulting Engineers

Bryan Johnson, PE

(916) 851-3500

Rancho Cordova, California 95670

11020 Sun Center Drive, Suite 100

06/02/20

PG102

PARTIAL SECOND FLOOR MED

GAS PLAN - DEMO & NEW

CONNECT TO EXISITNG ZONE VALVE BOX

CONNECT TO EXISITING MV, MA, O2.

STERIS C1 GAS OUTLETS:

- (1) NITROGEN

- (2) MED VAC

GASES PROVIDED AT C2 PERFUSION BOOM:

- (2) MED VAC

- (2) OXYGEN

- (1) CARBON DIOXIDE

- (2) MEDICAL AIR

STERIS C3 GAS OUTLETS:

- (1) NITROGEN OXIDE

- (1) MEDICAL AIR

- (2) OXYGEN

- (1) WASTE ANESTHESIA GAS DISPOSAL

- (3) MED VAC

STERIS C6 GAS OUTLETS:

- (2) MED VAC

- (2) OXYGEN

- (1) CARBON DIOXIDE

- (2) MEDICAL AIR

3DEMOLITION WORK KEYNOTES

DEMO (E) O, N, N20, MED AIR, MED VAC & CO2 BACK TO ZVB. 1

2 DEMO (E) O, MED AIR, MED VAC TO POINTS SHOWN.

SCALE:PG102 3/16" = 1'-0"

2 SECOND FLOOR MED GAS NEW PLAN

NEW WORK SHEET NOTES

FOLLOW ALL MANUFACTURER'S INSTRUCTIONS AND

RECOMMENDATIONS FOR MAKING CONNECTIONS TO BOOM MANIFOLD

PLATES. PROVIDE ALL NECESSARY COUPLINGS AND FITTINGS

REGQUIRED FOR CONNECTIONS.

1.

WALL GAS OUTLETS:

- (2) MED VAC

- (2) OXYGEN

- (1) CARBON DIOXIDE

- (2) MEDICAL AIR

NEW WORK KEYNOTES

Revisions: Date:

3 DEMO (E) O, N TO POINTS SHOWN AND PREPARE FOR

CONNECTION TO NEW. CAP REMAINING MAIN AIR TIGHT

SCALE:PG102 3/16" = 1'-0"

1 SECOND FLOOR MED GAS DEMO PLAN

INSTALL NEW WAGD GAS VALVE AND VACUUM

SWITCH, CONNECT BACK TO AREA ALARM PANEL.

M 24700

STAT E OF CALIFORNIA

RE

E

NI

GN

E

LANOISSEFORP

DERET

SI

G E

R

S R

EYM.AEHP

E T

S

EXPIRES 3/31/21

MECHAN ICA L

DATE SIGNED:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

MECHANICAL:

Gene Klow, AIA

(855) 521-1110

Alexandria, Virginia 22314

123 S Royal Street

Concourse Federal Group

100% BID SET VAPAHCS Cath Lab Suite Upgrade

640-13-134

3801 Miranda Avenue, Palo Alto, CA

07/10/2020

Capital Consulting Engineers

Bryan Johnson, PE

(916) 851-3500

Rancho Cordova, California 95670

11020 Sun Center Drive, Suite 100

06/02/20

PL501

PLUMBING DETAILS

M 24700

STAT E OF CALIFORNIA

RE

E

NI

GN

E

LANOISSEFORP

DERET

SI

G E

R

S R

EYM.AEHP

E T

S

EXPIRES 3/31/21

MECHAN ICA L

DATE SIGNED:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

MECHANICAL:

Gene Klow, AIA

(855) 521-1110

Alexandria, Virginia 22314

123 S Royal Street

Concourse Federal Group

100% BID SET VAPAHCS Cath Lab Suite Upgrade

640-13-134

3801 Miranda Avenue, Palo Alto, CA

07/10/2020

Capital Consulting Engineers

Bryan Johnson, PE

(916) 851-3500

Rancho Cordova, California 95670

11020 Sun Center Drive, Suite 100

06/02/20

PL601

PLUMBING DIAGRAMS

SYMBOL LEGEND

ABBREVIATIONS

SYMBOL LEGENDGENERAL NOTES

LIGHTING FIXTURE SCHEDULE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

E0-1

ELECTRICAL SYMBOL LEGEND,

ABBREVIATIONS, GENERAL NOTES

AutoCAD SHX Text

CONDUIT CONCEALED IN CEILING OR WALLS

AutoCAD SHX Text

EXISTING CONDUIT & WIRING

AutoCAD SHX Text

OF #12 WIRES, 2#12 & 1#12 GRD IN 3/4"C IF NOT MARKED

AutoCAD SHX Text

HOMERUN CONDUIT TO PANELBOARD, SLASH MARKS INDICATE NUMBER

AutoCAD SHX Text

EQUIPMENT CONNECTION. FIELD VERIFY LOCATION.

AutoCAD SHX Text

DIGITAL DIMMING SWITCH CONTROL, WATTSTOPPER LMDM-101-U OR EQUAL.

AutoCAD SHX Text

THREE WAY WALL SWITCH - EXISTING, NEW RESPECTIVELY, +42" TO

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

SINGLE POLE WALL SWITCH - EXISTING, NEW RESPECTIVELY, +42" TO

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

WALL MOUNTED ILLUMINATED EXIT SIGN, ARROW AS NOTED - EXISTING,

AutoCAD SHX Text

NEW RESPECTIVELY

AutoCAD SHX Text

CEILING MOUNTED ILLUMINATED EXIT SIGN, ARROW AS NOTED -

AutoCAD SHX Text

EXISTING, NEW RESPECTIVELY

AutoCAD SHX Text

WALL MOUNTED SPECIAL PURPOSE RECEPTACLE OUTLET

AutoCAD SHX Text

EXISTING, NEW RESPECTIVELY, +18"AFF

AutoCAD SHX Text

WALL MOUNTED FOURPLEX RECEPTACLE, 2-20A,120V,2P,3W GROUNDED -

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING, NEW RESPECTIVELY, +18"AFF. "A" DENOTES ABOVE COUNTER

AutoCAD SHX Text

WALL MOUNTED DUPLEX RECEPTACLE, 20A,120V,2P,3W GROUNDED -

AutoCAD SHX Text

AutoCAD SHX Text

RESPECTIVELY

AutoCAD SHX Text

WALL MOUNTED JUNCTION BOX, SIZE TO SUIT - EXISTING, NEW

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

RESPECTIVELY

AutoCAD SHX Text

CEILING MOUNTED JUNCTION BOX, SIZE TO SUIT - EXISTING, NEW

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

PUSH BUTTON CONTROL STATION.

AutoCAD SHX Text

FIXTURE TAG. SEE FIXTURE SCHEDULE FOR FIXTURE DESCRIPTION

AutoCAD SHX Text 3/32

AutoCAD SHX Text A

AutoCAD SHX Text

SHEET NOTE TAG

AutoCAD SHX Text

AutoCAD SHX Text

DETAIL OR DIAGRAM TAG

AutoCAD SHX Text E-1

AutoCAD SHX Text

AutoCAD SHX Text

PANELBOARD - EXISTING, NEW RESPECTIVELY

AutoCAD SHX Text

AutoCAD SHX Text

SINGLE POLE WALL SWITCH WITH DUAL TECHNOLOGY OCCUPANCY SENSOR,

AutoCAD SHX Text

+42" TO THE MIDDLE OF BOX AFF. WATT STOPPER #DW-100 OR EQUAL.

AutoCAD SHX Text

DUAL RELAY WALL SWITCH WITH DUAL TECHNOLOGY OCCUPANCY SENSOR,

AutoCAD SHX Text

+42" TO THE MIDDLE OF BOX AFF. WATT STOPPER #DW-203 OR EQUAL.

AutoCAD SHX Text

CEILING SPEAKER, EXISTING, NEW RESPECTIVELY

AutoCAD SHX Text

AMPERE

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

CONDUIT

AutoCAD SHX Text

CONDUIT ONLY

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

GROUND FAULT INTERRUPTER

AutoCAD SHX Text

HORSEPOWER

AutoCAD SHX Text

NEW

AutoCAD SHX Text

EXISTING TO BE REMOVED

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

UNLESS OTHERWISE NOTED

AutoCAD SHX Text

UNINTERRUPTIBLE POWER SUPPLY SYSTEM

AutoCAD SHX Text A

AutoCAD SHX Text

AFF

AutoCAD SHX Text C

AutoCAD SHX Text

CO

AutoCAD SHX Text (E)

AutoCAD SHX Text

GFI

AutoCAD SHX Text

HP

AutoCAD SHX Text (N)

AutoCAD SHX Text (R)

AutoCAD SHX Text

TYP

AutoCAD SHX Text

UON

AutoCAD SHX Text

UPS

AutoCAD SHX Text

NL

AutoCAD SHX Text

NIGHT LIGHT

AutoCAD SHX Text

FSD

AutoCAD SHX Text J

AutoCAD SHX Text

FIRE SMOKE DAMPER. FURNISHED & INSTALLED BY MECHANICAL

AutoCAD SHX Text

(RL)

AutoCAD SHX Text

RELOCATED DEVICE OR EQUIPMENT

AutoCAD SHX Text

EXISTING DEVICE OR EQUIPMENT TO BE REMOVED

AutoCAD SHX Text

(RR)

AutoCAD SHX Text

AND REUSED AT A NEW LOCATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text D

AutoCAD SHX Text

WALL MOUNTED DUPLEX RECEPTACLE CONNECTED TO EMERGENCY POWER -

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING, NEW RESPECTIVELY. RECEPTACLE AND FACEPLATE COLOR SHALL BE RED

AutoCAD SHX Text

ABOVE LAVATORY SINK

AutoCAD SHX Text

WALL MOUNTED DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER,

AutoCAD SHX Text

GFI

AutoCAD SHX Text U

AutoCAD SHX Text

CONDUIT CONCEALED IN OR UNDER SLAB OR UNDERGROUND

AutoCAD SHX Text

OF #12 WIRES (UON), WHERE IN EXCESS OF 2. (NOT COUNTING

AutoCAD SHX Text

HOMERUN CONDUIT TO PANELBOARD, SLASH MARKS INDICATE NUMBER

AutoCAD SHX Text

INSUL. GND

AutoCAD SHX Text

REQUIRED EQUIPMENT GROUND IN CONDUITS). CROSS LINE WITH DOT

AutoCAD SHX Text

INDICATES INSULATED GROUND WIRE IN ADDITIONAL TO EQUIPMENT GROUND.

AutoCAD SHX Text

(E) DENOTES FOR EXISTING IN OPERATION.

AutoCAD SHX Text (E)

AutoCAD SHX Text M

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text

MOTOR OUTLET CONNECTION

AutoCAD SHX Text

MANUAL MOTOR STARTER DISCONNECT

AutoCAD SHX Text

MANUFACTURER'S RECOMMENDATIONS

AutoCAD SHX Text

NON-FUSED DISCONNECT SWITCH, HP RATED

AutoCAD SHX Text

FUSED DISCONNECT SWITCH, HP RATED, SIZE FUSES PER

AutoCAD SHX Text

COMBINATION STARTER AND CIRCUIT BREAKER DISCONNECT, HP RATED

AutoCAD SHX Text

DISCONNECT SWITCH, HP RATED WITH AUXILARY CONTACT

AutoCAD SHX Text

FLOOR MOUNTED RECEPTACLE, 20A, 120V, 2P, 3W GROUNDED

AutoCAD SHX Text

ALL CONDUITS THRU WALL AND FLOOR SHALL BE SEALED AIR-TIGHT AROUND

AutoCAD SHX Text

CONDUIT OPENING WITH CODE APPROVED MATERIAL. FIRE RATING OF WALLS OR

AutoCAD SHX Text

FLOORS SHALL BE MAINTAINED.

AutoCAD SHX Text

ALL WALL OUTLETS SHALL BE MOUNTED +18" ABOVE FINISHED FLOOR UNLESS

AutoCAD SHX Text

OTHERWISE NOTED.

AutoCAD SHX Text

REMOVE UNUSED WIRES FROM CONDUITS BACK TO PANEL OF ORIGIN. REMOVE

AutoCAD SHX Text

SURFACE MOUNTED OR SUSPENDED CONDUITS THAT ARE NO LONGER IN USE FROM

AutoCAD SHX Text

CEILING BACK TO NEAREST OUTLET BOX OR FITTING ADJACENT TO PANEL OF

AutoCAD SHX Text

ORIGIN.

AutoCAD SHX Text

OPENINGS THRU CEILING FOR CONDUITS SHALL BE COVERED WITH ESCUTCHEON

AutoCAD SHX Text

PLATES.

AutoCAD SHX Text

RECESS MOUNTED FIXTURE INSTALLED IN SUSPENDED CEILING SHALL BE

AutoCAD SHX Text

INDEPENDENTLY SUPPORTED BY MEANS OF #12 WIRES FROM EACH CORNER TO

AutoCAD SHX Text

STRUCTURE ABOVE.

AutoCAD SHX Text

PROVIDE TELELPHONE/DATA CABLES IN ALL TELEPHONE/DATA CONDUITS.

AutoCAD SHX Text

CONDUITS AND LIGHTING FIXTURES SHALL NOT BE MOUNTED TO BUS OR VENT

AutoCAD SHX Text

DUCTS OR CABLE RACKS. UNISTRUT P-1000 SHALL BE SUSPENDED BELOW OR

AutoCAD SHX Text

TIGHT TO BOTTOM OF DUCT WITH 3/8" THREADED RODS HUNG FROM STRUCTURE

AutoCAD SHX Text

ABOVE. DO NOT SUPPORT CONDUITS AND LIGHTING FIXTURES WITH SUSPENDED

AutoCAD SHX Text

CEILING SUPPORT SYSTEM.

AutoCAD SHX Text

ALL PANEL CIRCUIT DIRECTORIES SHALL BE UPDATED IN ACCORDANCE WITH THE

AutoCAD SHX Text

LATEST CIRCUITRY. DIRECTORIES SHALL BE TYPEWRITTEN.

AutoCAD SHX Text

PATCH AND REPAINT EXISTING WALL AFTER CUTTING TO MATCH EXISTING AT

AutoCAD SHX Text

COMPLETION OF ALL WORK.

AutoCAD SHX Text

AND PULLBOXES TO REROUTE EXISTING CIRCUITS TO NEW ACCESSIBLE LOCATIONS.

AutoCAD SHX Text

OUTLETS AND SWITCHES ARE REMOVED. PROVIDE NECESSARY JUNCTION BOXES

AutoCAD SHX Text

PROVIDE NECESSARY CONDUIT AND WIRING TO CONTINUE CIRCUITING WHEN

AutoCAD SHX Text

CONDUIT SHALL RUN CONCEALED. EXPOSED CONDUIT IS NOT ALLOWED.

AutoCAD SHX Text

ALL CONDUIT AND WIRING SHALL BE NEW UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

FURNISH AND INSTALL DUST TIGHT FIRE RESISTANT PROTECTIVE COVERING OVER

AutoCAD SHX Text

EXISTING EQUIPMENT WHEN INSTALLING ANY NEW WORK.

AutoCAD SHX Text

REFER TO ARCHITECTURAL DRAWING FOR EXACT CEILING TYPE AND LIGHTING

AutoCAD SHX Text

OF ALL FIXTURES AS REQUIRED.

AutoCAD SHX Text

FIXTURE LAYOUT. VERIFY WITH ARCHITECTURAL DRAWING FOR MOUNTING HEIGHT

AutoCAD SHX Text

MINIMUM SIZE OF CONDUIT SHALL BE 3/4"C FOR POWER AND

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text 4.

AutoCAD SHX Text 5.

AutoCAD SHX Text 6.

AutoCAD SHX Text 7.

AutoCAD SHX Text 8.

AutoCAD SHX Text 9.

AutoCAD SHX Text 10.

AutoCAD SHX Text 11.

AutoCAD SHX Text 12.

AutoCAD SHX Text 13.

AutoCAD SHX Text 14.

AutoCAD SHX Text 15.

AutoCAD SHX Text 16.

AutoCAD SHX Text

INDIVIDUAL GROUPINGS.

AutoCAD SHX Text

RUNNING IN EACH CONDUIT SHALL BE TIE-WRAPPED SO THAT THEY REMAIN IN

AutoCAD SHX Text

(BOTH PANEL NAME AND CIRCUIT BREAKER NUMBER). EACH BUNDLE OF WIRING

AutoCAD SHX Text

ALL WIRING INSIDE PULL BOXES SHALL BE TAGGED TO IDENTIFY THE CIRCUIT

AutoCAD SHX Text

WHITE LETTERS ON BLACK BAKELITE BACKGROUND.

AutoCAD SHX Text

PERMANENTLY IDENTIFIED WITH MACHINE SCREWED ENGRAVED NAMEPLATES WITH

AutoCAD SHX Text

DISCONNECT SWITCHES, MOTOR STARTERS AND CONTROL PANELS SHALL BE

AutoCAD SHX Text

ALL ELECTRICAL CABINET ENCLOSED APPARATUS, SWITCHBOARDS, PANELBOARDS,

AutoCAD SHX Text

DYMO TAPE. THE TAPE SHOULD SHOW PANEL NAME AND CIRCUIT BREAKER NUMBER

AutoCAD SHX Text

CONTRACTOR SHALL LABEL EACH NEW AND EXISTING ELECTRICAL OUTLETS WITH

AutoCAD SHX Text

FEEDING THE OUTLET.

AutoCAD SHX Text

ALL ELECTRICAL EQUIPMENT, DISCONNECT SWITCHES, PANELBOARDS, CONTROL

AutoCAD SHX Text

DEVICES SHALL BE IDENTIFIED WITH ENGRAVED NAMEPLATES.

AutoCAD SHX Text

ALL SURFACE MOUNTED ELECTRICAL EQUIPMENT AND DEVICES SHALL BE PROPERLY

AutoCAD SHX Text

SECURED TO WALL.

AutoCAD SHX Text

ALL EQUIPMENT AND DEVICES SHOWN SHALL BE NEW UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

FOR (3) CIRCUITS. SIZE AND CONNECT GROUND WIRE IN ACCORDANCE WITH

AutoCAD SHX Text

PROVIDE SEPARATE GROUND WIRE IN ALL CONDUITS. MINIMUM (1) GROUND WIRE

AutoCAD SHX Text

NATIONAL ELECTRICAL CODE. PROVIDE SEPARATE NEUTRAL FOR EACH 1%%C, 2%%C OR

AutoCAD SHX Text

ALL MECHANICAL LINE AND LOW VOLTAGE CONTROLS AND INTERLOCKING WIRING

AutoCAD SHX Text

AND CONDUIT REQUIRED FOR THE HVAC/PLUMBING EQUIPMENT SHALL BE PROVIDED

AutoCAD SHX Text

UNDER MECHANICAL.

AutoCAD SHX Text 17.

AutoCAD SHX Text 18.

AutoCAD SHX Text 19.

AutoCAD SHX Text 20.

AutoCAD SHX Text 21.

AutoCAD SHX Text 22.

AutoCAD SHX Text 23.

AutoCAD SHX Text 24.

AutoCAD SHX Text

ALL POWER AND TELECOMMUNICATION SYSTEM OUTLETS MOUNTED BACK TO BACK

AutoCAD SHX Text

ARE PROHIBITED. A MINIMUM 24", CENTER-TO-CENTER SPACING SHALL BE

AutoCAD SHX Text

MAINTAINED BETWEEN BOXES.

AutoCAD SHX Text

PROVIDE INDIVIDUAL GFI RECEPTACLE AT EACH LOCATION SHOWN, DO NOT USE

AutoCAD SHX Text

FEED-THRU GFI TYPE RECEPTACLE.

AutoCAD SHX Text 25.

AutoCAD SHX Text 26.

AutoCAD SHX Text

CONDUIT AFTER CONDUIT INSTALLATION WITH CODE APPROVED MATERIALS.

AutoCAD SHX Text

CONDUIT PENETRATIONS THRU WALL AND/OR FLOOR SHALL BE GROUTED AROUND

AutoCAD SHX Text

ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE PROVIDED WITH SPECIFIED

AutoCAD SHX Text

EXPANSION/DEFLECTION FITTINGS.

AutoCAD SHX Text 27.

AutoCAD SHX Text 28.

AutoCAD SHX Text

3%%C CIRCUITS WHERE REQUIRED (3-HOT, 3-NEUTRAL, 1-GROUND FOR 3-CIRCUITS).

AutoCAD SHX Text

POWER AND TEL/DATA OUTLETS THAT ARE NOT REUSED SHALL BE REMOVED.

AutoCAD SHX Text

PATCH WALL AND PAINT TO MATCH EXISTING ADJACENT FINISH.

AutoCAD SHX Text

WALL MOUNTED FIXTURE WITH OUTLET - EXISTING,

AutoCAD SHX Text

AutoCAD SHX Text

CEILING MOUNTED FIXTURE WITH OUTLET - EXISTING,

AutoCAD SHX Text

AutoCAD SHX Text

CEILING RECESS MOUNTED DOWN LIGHT FIXTURE WITH OUTLET - EXISTING,

AutoCAD SHX Text

NEW RESPECTIVELY

AutoCAD SHX Text

AutoCAD SHX Text

CEILING MOUNTED FIXTURE WITH OUTLET CONNECTED

AutoCAD SHX Text

RESPECTIVELY

AutoCAD SHX Text

NEW RESPECTIVELY

AutoCAD SHX Text

TO LIFE SAFETY EMERGENCY CIRCUIT

AutoCAD SHX Text

(EACH CIRCUIT SHALL HAVE EACH OWN NEUTRAL SEPARATE)

AutoCAD SHX Text

DOUBLE POLE SINGLE THROW SWITCH

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

RESPECTIVELY

AutoCAD SHX Text

CEILING MOUNTED IONIZATION SMOKE DETECTOR - EXISTING, NEW

AutoCAD SHX Text

AutoCAD SHX Text

FIRE ALARM STROBE LIGHT, +80"AFF

AutoCAD SHX Text

FIRE ALARM MANUAL PULLSTATION - EXISTING, NEW RESPECTIVELY, +42" TO

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

NURSE'S CALL DOME LIGHT, MOUNTED 6" ABOVE DOOR

AutoCAD SHX Text

NURSE'S CALL DOME LIGHT, CEILING MOUNTED

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

1"C FOR TEL/DATA, UON.

AutoCAD SHX Text

THE MIDDLE OF BOX AFF

AutoCAD SHX Text

THE MIDDLE OF BOX AFF

AutoCAD SHX Text

THE MIDDLE OF BOX AFF

AutoCAD SHX Text

FIRE ALARM SPEAKER/STROBE UNIT, +80"AFF

AutoCAD SHX Text

FATC

AutoCAD SHX Text

FIRE ALARM TERMINAL CABINET

AutoCAD SHX Text

EOL

AutoCAD SHX Text

END OF LINE RESISTOR

AutoCAD SHX Text

DD

AutoCAD SHX Text

DUCT SMOKE DETECTOR

AutoCAD SHX Text

FSD

AutoCAD SHX Text

FIRE SMOKE DAMPER

AutoCAD SHX Text

DIGITAL ROOM CONTROLLER AND ALL NECESSARY MOUNTING HARDWARE,

AutoCAD SHX Text

CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. COMPLETE WITH

AutoCAD SHX Text

WATTSTOPPER LMDC-100-U AND LMRC-210 SERIES OR EQUAL.

AutoCAD SHX Text

DIMMING ROOM CONTROLLER. SEE E7-1 FOR DETAILS AND DIAGRAMS.

AutoCAD SHX Text

RM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

VOLTS

AutoCAD SHX Text

LAMPS

AutoCAD SHX Text F6

AutoCAD SHX Text 2' x 4' RECESSED LED FIXTURE WITH DIFFUSER 5 YEAR LIMITED WARRANTY, 0-10V DIMMING DRIVER 5238 LUMENS, 60,000 HRS, L80

AutoCAD SHX Text

38W LED 3500K 80CRI

AutoCAD SHX Text

LITHONIA# 2VTL4-48L-ADP-EZ1-LP835-USPOM OR EQUAL

AutoCAD SHX Text F7

AutoCAD SHX Text

LITHONIA# 2VTL2-33L-ADP-EZ1-LP835-USPOM OR EQUAL

AutoCAD SHX Text

26W LED 3500K 80CRI

AutoCAD SHX Text 2' x 2' RECESS LED FIXTURE WITH 5 YEAR LIMITED WARRANTY. 0-10V DIMMING DRIVER. 3299 LUMENS. 60,000 HRS, L80.

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text F8

AutoCAD SHX Text

AMICO LIGHTING# L-SKY-4-277-LED35-2/2-LMD

AutoCAD SHX Text

112.3W LED 3500K 90CRI

AutoCAD SHX Text 48" OVERBED WALL MOUNT LED. MARINE GRADE ALUMINUM EXTRUSION WITH POLYCARBONATE LENS. 0-10 DIMMING, 5-YEAR WARRANTY, 9,964 LUMENS. 50,000 HRS AT L70.

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text SURFACE/SURFACE END WALL MOUNTED LED EXIT SIGN WHITE FACE WITH RED LETTER. SEE PLANS FOR SINGLE OR DOUBLE AND ARROW. 90 MINUTES EMERGENCY BATTERY PACK AND SELF DIAGNOSTIC.

AutoCAD SHX Text

2.7W LED

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text

LITHONIA# LRP-W-X-RW-X-120/277-ELN-X OR EQUAL

AutoCAD SHX Text X

AutoCAD SHX Text F5

AutoCAD SHX Text CLEAN-TRAK GRID SYSTEM INTEGRATED FLUSH LIGHTING IN GRID CHANNEL. SEE DRAWING SHEETS EQ101 AND EQ102 FOR FIXTURE LENGTH AND SPECIFICATION. 0-10V DIMMING DRIVER

AutoCAD SHX Text

6.8W/LF LED 4000K 80CRI

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text F1

AutoCAD SHX Text 4" DIA. RECESSED PARABOLIC LED FIXTURE WITH FROSTED CONVEXED LENS. 90 MINUTES EMERGENCY BATTERY PACK. 1280 LUMENS. 5 YEAR WARRANTY, 60,000 HRS, L80

AutoCAD SHX Text

ACUITY INDY# L4-15LM-MVOLT-G4-GZ1-BRT20C P-CD-WH-PF-HBTL

AutoCAD SHX Text

13.7W LED 4000K 80CRI

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text F9

AutoCAD SHX Text

20W LED

AutoCAD SHX Text 120V

AutoCAD SHX Text PROVIDE SPECIAL SIGN FACE AS MARKED BELOW: "X-RAY IN USE" LED WARNING LIGHT IN CATHLAB ROOM AND "X-RAY IN USE" LED WARNING LIGHT IN SCAN ROOM

AutoCAD SHX Text

LITHONIA # LE-P-1-R-SW16 OR ALTERNATE APPROVED DUAL LITE

AutoCAD SHX Text

EMERGENCY POWER 4 PLEX OUTLET. RECEPTACLE AND FACEPLATE COLOR SHALL BE RED

AutoCAD SHX Text NEW WALL MOUNTED TEL/DATA COMMUNICATION OUTLET, +18"AFF UON. TERMINATE 1 1/4"C WITH BUSHING +6" ABOVE SUSPENDED CEILING. ROUTE CABLES FROM EACH TEL/DATA COMMUNICATION OUTLET TO PATCH PANELS/110 BLOCKS IN TEL/DATA CLOSET RESPECTIVELY. PROVIDE (4) CABLE CAT-6 RUNS WITH TWO VOICE AND TWO DATA. TYPICAL UNLESS OTHERWISE NOTED.

AutoCAD SHX Text NEW WALL MOUNTED TELEPHONE COMMUNICATION OUTLET, +48"AFF UON. TERMINATE 1"C WITH BUSHING +6" ABOVE SUSPENDED CEILING. ROUTE CABLES FROM EACH TELEPHONE COMMUNICATION OUTLET TO 110 BLOCKS IN TELEPHONE CLOSET. PROVIDE (1) CABLE CAT-6 RUNS WITH ONE VOICE. TYPICAL UNLESS OTHERWISE NOTED.

AutoCAD SHX Text NEW WALL MOUNTED DATA COMMUNICATION OUTLET, +18"AFF UON. TERMINATE 1 1/4"C WITH BUSHING +6" ABOVE SUSPENDED CEILING. ROUTE CABLES FROM DATA COMMUNICATION OUTLET TO PATCH PANELS IN DATA CLOSET. PROVIDE (2) CABLE CAT-6 RUNS WITH TWO DATA. TYPICAL UNLESS OTHERWISE NOTED.

AutoCAD SHX Text N

AutoCAD SHX Text

CB

AutoCAD SHX Text CODE BLUE STATION. PROVIDE 2 7/8"C DEEP SINGLE-GANG BACKBOX AND ROUTE 1"C CONDUIT TO THE NEAREST CABLE TRAY.

AutoCAD SHX Text NURSE CALL STATION - PUSH BUTTON AND PULL STRING. PROVIDE 2 7/8"C DEEP SINGLE-GANG BACKBOX AND ROUTE 1"C CONDUIT TO THE NEAREST CABLE TRAY. "SE" DENOTES STAFF EMERGENCY UNIT.

AutoCAD SHX Text

SE

AutoCAD SHX Text F10

AutoCAD SHX Text

19.4W LED 3500K 85CRI

AutoCAD SHX Text 3' UNDERCABINET LED FIXTURE WITH INTEGRAL OCCUPANCY SENSOR ROCKER SWITCH WHITE FINISH. 1930 LUMENS, 50,000 HRS

AutoCAD SHX Text

ACUITY # HUC535-MVOLT-LED35-S1- 0S-XX-GW

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text F2

AutoCAD SHX Text 4" DIA. RECESSED PARABOLIC LED FIXTURE WITH FROSTED CONVEXED LENS. 2727 LUMENS. 5 YEAR WARRANTY, 60,000 HRS, L80

AutoCAD SHX Text

ACUITY INDY# L4-33LM-MVOLT-G4-GZ1- P-CD-WH-PF-HBTL

AutoCAD SHX Text

33.6W LED 3500K 80CRI

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text F4

AutoCAD SHX Text 4" DIA. RECESSED PARABOLIC LED FIXTURE WITH FROSTED CONVEXED LENS. 1097 LUMENS. 5 YEAR WARRANTY, 60,000 HRS, L80

AutoCAD SHX Text

ACUITY INDY# L4-13LM-MVOLT-G4-GZ1- P-CD-WH-WET

AutoCAD SHX Text

11.7W LED 3500K 80CRI

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text F3

AutoCAD SHX Text 4" DIA. RECESSED HYPERBOLIC LED FIXTURE WITH CLEAR DIFFUSER LENS. 4366 LUMENS. 5 YEAR WARRANTY, 60,000 HRS, L80

AutoCAD SHX Text

ACUITY INDY# L4-40LM-MVOLT-G4-GZ1- HW-CD-WH-PF-HBTL

AutoCAD SHX Text

41.7W LED 3500K 80CRI

AutoCAD SHX Text 120- 277V

AutoCAD SHX Text

PROVIDE SUBMITTAL CUTSHEETS AS INDICATED ON DRAWING SHEETS PER "EQ" SERIES.

AutoCAD SHX Text 29.

AutoCAD SHX Text 30.

AutoCAD SHX Text

CONTRACTOR SHALL COORDINATE WIRE SIZE AND TERMINATION WITH EQUIPMENT INSTALLER

AutoCAD SHX Text 31.

AutoCAD SHX Text

AS SHOWN ON "EQ" SERIES DRAWING SET.

AutoCAD SHX Text

CONTRACTOR SHALL CONFIRM CIRCUIT LENGTH AND WIRE CAPACITY DOES NOT EXCEED

AutoCAD SHX Text 32.

AutoCAD SHX Text

RESTRICTIONS LISTED IN FEEDER TABLE ON "EQ202".

AutoCAD SHX Text CONTRACTOR SHALL PROVIDE NEW CIRCUIT BREAKERS AND CONDUCTORS TO FEED EXISTING / NEW MECHANICAL EQUIPMENT.

AutoCAD SHX Text F11

AutoCAD SHX Text

120W LED 5500K

AutoCAD SHX Text WALL MOUNT PROCEDURE LIGHT (6) LEDS WITH TOUCHLESS ON/OFF CONTROL AND DIMMING. 50,000 HRS

AutoCAD SHX Text

WELCH ALLYN GREEN SERIES 900 44900-W

AutoCAD SHX Text 120V

AutoCAD SHX Text

NEW CEILING MOUNTED DATA COMMUNICATION OUTLET

AutoCAD SHX Text ALL WORK SHALL COMPLY WITH: NFPA 70 - 2017 NFPA 90 - 2015 OR AS SPECIFIED IN VA TECHNICAL INFORMATION LIBRARY (TIL) ANSI/ASHRAE/IESNA STANDARD 90.1 ILLUMUNATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) LIGHTING HANDBOOK

AutoCAD SHX Text

DAYLIGHT PHOTOSENSOR. SEE E7-1 FOR DETAILS AND DIAGRAMS.

AutoCAD SHX Text

PS

AutoCAD SHX Text

EMERGENCY LIGHTING CONTROL UNIT WITH POWER PACK

AutoCAD SHX Text

ELCU

AutoCAD SHX Text

FIRE ALARM CONTROL PANEL

AutoCAD SHX Text

FACP

AutoCAD SHX Text

HEATING VENTILATION AIR CONDITIONING

AutoCAD SHX Text

HVAC

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

CL12A QL12A SL12A

SH12A

QH12A

NH12A

LCP12A

CH12A

NL12A

N

TX

A

141516

B

C

D

A

E

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

E0-2

OVERALL FIRST FLOOR -

REFERENCE PLAN

OVERALL FIRST FLOOR - REFERENCE PLAN

N

-10 20

FEETSCALE: 1" = 20'-0"

100 40

AutoCAD SHX Text

AREA OF WORK ON THE 2ND FLOOR ABOVE

AutoCAD SHX Text

MECHANICAL SHAFT

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

AutoCAD SHX Text

MAIN ELECTRICAL SERVICE #2

AutoCAD SHX Text

MAIN ELECTRICAL SERVICE #1

AutoCAD SHX Text

ELECTRICAL RM E1-EC

AutoCAD SHX Text

ELECTRICAL RM E1-EC4

AutoCAD SHX Text

ELECTRICAL RM A1-EC2

AutoCAD SHX Text

ELECTRICAL RM A1-EC1

AutoCAD SHX Text

ELECTRICAL RM C1-EC3

AutoCAD SHX Text

ELECTRICAL RM F1-EC6

AutoCAD SHX Text

SCALE: 1" = 20'-0"

(E) DISTRIBUTION PANEL "QHD1002B"

17 16 15 14 13 12

STAIRWAY

ST-2

228 SF

(E)

UP DN

A

(E) 2 PHYS

OFF

E2-437

191 SF

100 2

LOCKERS

E2-426

131 SF

NUR/TECH

E2-435

91 SF

(E)

100 1 B

(E) CH CATH

E2-433

112 SF

100 2

CH/NON-INV

E2-431

113 SF

(E)

100 2

CH/NON-INV

E2-429

124 SF

(E)

100 2 C

(E) RES

TRNG

E2-333

105 SF

(E) ASST CH

E2-331

116 SF

(E) SECY 02

E2-329

124 SF

D

(E) CHIEF

E2-327

159 SF (E) CLRM

E2-341

388 SF

(E) ORAL

SURG

1/TRNG

E2-325

179 SF

(E) CORR

E2-C21

739 SF

(E) CORR

E2-C22

726 SF

E

(E) ORAL

SURG 2

E2-323

150 SF

(E) PREP

E2-330

103 SF

(E) STER

E2-340

116 SF

(E) STORAGE

E2-342

173 SF

(E) CART

LIFT 2

(E) TMT 13

E2-344

132 SF

(E) HAC

E2-348

43 SF (E) CORR

E2-C23

306 SF

C-2

56 SF

(E) PATIENT

TOILET

E2-346

36 SF

(E) DARK

E2-350

136 SF

(E) STORAGE

E2-360C

92 SF

(E) PLASTER

E2-360B

129 SF

PORCELAIN

E2-360A

120 SF

(E)

(E) TMT 01

E2-345

155 SF

(E) TMT 02

E2-347

158 SF

(E) ELEC

E-2.2

164 SF

300 1

HYBRID OR

E2-427

907 SF

240 4

CATH LAB

E2-410

582 SF

240 3

(E) TECH

E2-411

109 SF

300 1

(E) TMT 14

E2-349

153 SF

(E) MECH

SHAFT

M-2

173 SF (E) DIAG

F2-118

149 SF

(E) PROS

LAB

E2-360

402 SF (E) PAT BR

F2-117

116 SF

E

(E) TMT 15

E2-351

166 SF

DENTURES

E2-360D

174 SF

(E)

BURNOUT

E2-360E

77 SF

(E)

(E) ECG

WORK

E2-403

186 SF

(E) PAT BR

F2-119

116 SF

D

(E) TEL/DATA

T-2.2

100 SF

300 1

SOILED

HOLD

E2-412

38 SF

300 1

(E) SCRUB

E2-410A

117 SF

100 2

(E) WAIT &

CATH GEN.

EQUIP.

E2-410B

100 3

218 SF

(E) MECH

SHAFT

M-7.2

23 SF

(E) ECG

EXAM

E2-401

80 SF

(E) CORR

E2-C30

857 SF

(E) CORR

F2-C23

103 SF

(E) OFFICE

E2-462

91 SF

RECEPTION

F2-370

287 SF

C

(E) CORR

E2-C34

952 SF

0 0

HYBRID GEN

E2-425B

90 SF

100 1

100 2

TOILET

E2-430

0 0

48 SF

SEMI-RESTRICTED

HALLWAY

E2-C33

237 SF

0 0

HYBRID

CONTROL

E2-425A

158 SF

100 2

TOILET

E2-432

0 0

48 SF

SUPPLY

E2-424

197 SF

CLEAN

300 1

MONITOR

E2-422A

78 SF

HOLD/

240 1

MONITOR

E2-422B

80 SF

HOLD/

240 1

SCRUB

E2-423

66 SF

100 1

PUMP/

ANESTHESIA

EQUIP.

E2-421

100 SF

100 1

CT/CATH

CONTROL

E2-414

353 SF

100 4 (E) OFFICE

E2-460

78 SF

E2-C32

0 0

685 SF

CORR

(E) EQUIP

E2-453A

45 SF

300 1

(E) CATH LAB

E2-454

661 SF

240 3

(E) OFFICE

E2-458

87 SF

SCANNER

E2-453

413 SF

(E) CT

100 5

(E) SOILED

LINEN

E2-461

16 SF

300 1

(E) OFFICE

E2-456

88 SF

(E) PUBLIC

TOILET

F2-360

60 SF

(E) STAFF

LOUNGE

F2-372

195 SF

(E) CLEAN

LINEN

E2-459

154 SF

300 1

TEMPORARY

CLEAN

SUPPLY

ROOM

E2-455

199 SF

300 1

(E) OFFICE

E2-457

199 SF

100 2

(E) CORR

E2-C36

522 SF

0 0

(E) CORR

E2-C38

225 SF

EXIT

DISCHARGE

A

(E) CORR

E2-C37

271 SF

B

(E) SIGNAL

SG-2.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

E0-3

PARTIAL SECOND FLOOR

REFERENCE PLAN

PARTIAL SECOND FLOOR REFERENCE PLAN

N

-10 20

FEETSCALE

1" = 20'-0"

100 40

AutoCAD SHX Text

(E) NURSE CALL TERMINAL CABINET

AutoCAD SHX Text

(E) SECURITY TERMINAL CABINET

AutoCAD SHX Text

(E) FIRE ALARM TERMINAL CABINET

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

AutoCAD SHX Text

SCALE: 1" = 20'-0"

AREA OF WORK

CHIEF OFFICE

E2-437

OFFICE

E2-435

OFFICE

E2-433

OFFICE

E2-431

OFFICE

E2-429

ORAL SURGERY

OFFICE

E2-333

RESIDENCY PROG

DIRECTOR

E2-331

ADMIN OFFICE

E2-329

TECH OFFICE

E2-411

ELEC

E-2-EC5

TEL/DATA

E2-TC5

CORRIDOR

E2-C36

TOILET

E2-432

TOILET

E2-430

LOCKERS

E2-426

CLEAN SUPPLY

E2-424

HOLD/MONITOR

E2-422A

PUMP/

ANESTHESIA

EQUIP

E2-421

SCRUB

E2-423

HYBRID CONTROL

E2-425A

HYBRID GEN

E2-425B

HYBRID OR

E2-427

121314151617 121314151617

B

C

D

A

B

C

D

A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

ED1-1

PARTIAL SECOND FLOOR

LIGHTING - EXISTING CONDITION

SHEET NOTES

N

2 2 4 6 8 100

FEETSCALE: 1/4" = 1'-0"

GENERAL NOTES

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text +76"

AutoCAD SHX Text +76"

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) 3/4"C (TYP)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) 3/4"C TO CEILING ABOVE

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (E)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) SL22A

AutoCAD SHX Text

(E) QL22A

AutoCAD SHX Text

(E) CH22A

AutoCAD SHX Text

(E) SH22A

AutoCAD SHX Text

(E) QH22A

AutoCAD SHX Text

(E) CL22A-1

AutoCAD SHX Text

(E) CL22A-2

AutoCAD SHX Text

(E) CTX22A

AutoCAD SHX Text

(E) STX22A

AutoCAD SHX Text

(E) NTX22B

AutoCAD SHX Text

(E) NH22A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) LCP22A

AutoCAD SHX Text 3/4"C

AutoCAD SHX Text

(R) 3/4"C

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

(E) 1/4"C TO CLG TEL +48"

AutoCAD SHX Text

(E) J-BOX WITH 3/4"C TO CLG

AutoCAD SHX Text

(E) J-BOX +40"

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text J

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text

(E) CONDUITS

AutoCAD SHX Text

(E) NL22B-3

AutoCAD SHX Text

(E) NL22B-1

AutoCAD SHX Text

(E) NL22B-2

AutoCAD SHX Text

(E) NL22A-1

AutoCAD SHX Text

(E) NL22A-2

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text

LV

AutoCAD SHX Text

LV

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (E)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text (R)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE FIXTURE

AutoCAD SHX Text

(TYP.)

AutoCAD SHX Text

(TYP.)

AutoCAD SHX Text

(TYP.)

AutoCAD SHX Text

(TYP.)

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

AutoCAD SHX Text

AutoCAD SHX Text CONTRACTOR SHALL UTILIZE EXISTING CONDUITS FOR LIGHTING CIRCUIT INSTALLATION. REMOVE JUNCTION BOX AND ASSOCIATED CONDUIT.

AutoCAD SHX Text

1. REMOVE ALL EXISTING WIRING IN THE REMOVE ALL EXISTING WIRING IN THE EXISTING CONDUIT AND PROVIDE NEW PULLWIRE AS REQUIRED. 2. CONTRACTOR SHALL VERIFY ALL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD.

OFFICE

E2-435

OFFICE

E2-433

OFFICE

E2-431

OFFICE

E2-429

ORAL SURGERY

OFFICE

E2-333

RESIDENCY PROG

DIRECTOR

E2-331

ADMIN OFFICE

E2-329

TECH OFFICE

E2-411

ELEC

E-2-EC5

TEL/DATA

E2-TC5

CORRIDOR

E2-C36

TOILET

E2-432

TOILET

E2-430

LOCKERS

E2-426

CLEAN SUPPLY

E2-424

HOLD/MONITOR

E2-422A

PUMP/

ANESTHESIA

EQUIP

E2-421

SCRUB

E2-423

HYBRID CONTROL

E2-425A

HYBRID GEN

E2-425B

HYBRID OR

E2-427

B

C

D

A

14151617

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

SHEET NOTES

ED1-2

N

2 2 4 6 8 100

FEETSCALE: 1/4" = 1'-0"

GENERAL NOTES

PARTIAL SECOND FLOOR

POWER - EXISTING CONDITION

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

(RR) PANEL "CL22IPA"

AutoCAD SHX Text

(E) PANEL "CL22IPB"

AutoCAD SHX Text

(E)3/4"C (TYP)

AutoCAD SHX Text J

AutoCAD SHX Text

(E)TEL

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

(E) SL22A

AutoCAD SHX Text

(E) QL22A

AutoCAD SHX Text

(E) CH22A

AutoCAD SHX Text

(E) SH22A

AutoCAD SHX Text

(E) QH22A

AutoCAD SHX Text

(E) CL22A-1

AutoCAD SHX Text

(E) CL22A-2

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

(E) CTX22A

AutoCAD SHX Text

(E) STX22A

AutoCAD SHX Text

(E) NTX22B

AutoCAD SHX Text

(E) NH22A

AutoCAD SHX Text

(E) NL22B-3

AutoCAD SHX Text

(E) NL22B-1

AutoCAD SHX Text

(E) NL22B-2

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) 3/4"C

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) CONDUITS

AutoCAD SHX Text

(E) CONDUITS

AutoCAD SHX Text

(E) CONDUITS

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

PULLBOX ABOVE CEILING

AutoCAD SHX Text

(E) PULLBOX ABOVE CEILING

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) CONDUITS

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) 3/4"C (TYP)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (R)

AutoCAD SHX Text (R)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) FLOOR OPENING

AutoCAD SHX Text

(E) NL22A-1

AutoCAD SHX Text

(E) NL22A-2

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

(E) LCP22A

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. REMOVE ALL EXISTING WIRING IN THE REMOVE ALL EXISTING WIRING IN THE EXISTING CONDUIT AND PROVIDE NEW PULLWIRE AS REQUIRED.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE AND REPLACE (E) PULLBOX WITH NEW (1) 6"X6"X3.5"AND (4) 4"X4"X3.5"JUNCTION BOXES TO CLEAR FOR CEILING SUPPORT STRUCTURE. PROVIDE ACCESS PANEL AT CEILING FOR NEW JUNCTION BOXES IN CEILING SPACE. REROUTE CONDUIT WITH ASSOCIATED WIRING AND PROVIDE LABELING OF POWER SOURCE FOR EACH JUNCTIN BOX AS REQUIRED.

AutoCAD SHX Text

RELOCATE EXSTING OUTLETS. SEE EP1-1 FOR NEW LOCATIONS. FIELD COORDINATE.

AutoCAD SHX Text

REMOVE OUTLET BOX AND ASSOCIATED CONDUIT.

AutoCAD SHX Text CONTRACTOR SHALL UTILIZE EXISTING CONDUITS FOR RECEPTACLE OUTLET CIRCUIT INSTALLATION.

AutoCAD SHX Text RELOCATE PANEL AND ASSOCIATED STUP-UP CONDUITS FROM THE PANEL TO CEILING SPACE, SEE EP1-1 FOR NEW PANEL LOCATION.

AutoCAD SHX Text

PROVIDE BLANK COVER PLATE

1" CONDUIT TO CEILING.

OFFICE

E2-435

OFFICE

E2-433

OFFICE

E2-431

OFFICE

E2-429

ORAL SURGERY

OFFICE

E2-333

RESIDENCY PROG

DIRECTOR

E2-331

ADMIN OFFICE

E2-329

TECH OFFICE

E2-411

ELEC

E-2-EC5

TEL/DATA

E2-TC5

CORRIDOR

E2-C36

TOILET

E2-432

TOILET

E2-430

LOCKERS

E2-426

CLEAN SUPPLY

E2-424

HOLD/MONITOR

E2-422A

PUMP/

ANESTHESIA

EQUIP

E2-421

SCRUB

E2-423

HYBRID CONTROL

E2-425A

HYBRID GEN

E2-425B

HYBRID OR

E2-427

B

C

D

A

14151617

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

SHEET NOTES

ED1-3

N

2 2 4 6 8 100

FEETSCALE: 1/4" = 1'-0"

PARTIAL SECOND FLOOR

TELECOM - EXISTING CONDITION

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text (E)4-4"C

AutoCAD SHX Text

(E)1 1/2"C EACH

AutoCAD SHX Text

(E)1 1/2"C EACH

AutoCAD SHX Text (E)1-4"C

AutoCAD SHX Text (E)2-2"C

AutoCAD SHX Text (E)2-2"C

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(E)CONDUIT

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text (E)2-2"C

AutoCAD SHX Text

AutoCAD SHX Text

(RR)

AutoCAD SHX Text

(E)CONDUIT

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E)CABLE TRAY

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(E) GROUND BUS BAR

AutoCAD SHX Text

(E) STUB-UP CONDUITS

AutoCAD SHX Text

(E) 110 BLOCK

AutoCAD SHX Text

(E) TEL. TERMINAL PLYWOOD BACKBOARD

AutoCAD SHX Text

(E) RACKS AND PATCH PANELS

AutoCAD SHX Text N

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(RR)

AutoCAD SHX Text (E)

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(E) (3) 3 1/2" DIAMETER FLOOR OPENING

AutoCAD SHX Text

(E) (1) 4 1/2" DIAMETER FLOOR OPENING

AutoCAD SHX Text

(E) FLOOR OPENING

AutoCAD SHX Text

(E) FLOOR OPENING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

AutoCAD SHX Text

AutoCAD SHX Text EXISTING 1 1/4"C FROM JUNCTION BOX UP TO CEILING SPACE ABOVE. CONTRACTOR SHALL UTILIZE EXISTING CONDUITS FOR TELEPHONE DATA OUTLET INSTALLATION. EXISTING 1"C FROM JUNCTION BOX UP TO CEILING SPACE ABOVE. RELOCATE PULLBOX TO CLEAR FOR CEILING SUPPORT STRUCTURE. REROUTE CONDUIT WITH ASSOCIATED WIRING AS REQUIRED. PROVIDE ACCESS PANEL AT CEILING FOR PULLBOX IN CEILING SPACE. PROVIDE ACCESS PANEL AT CEILING FOR (E) CABLE TRAY AT CEILING SPACE. REMOVE 1 1/4"C AND ASSOCIATED JUNCTION BOX TO CLEAR FOR THE NEW DOOR. COORDINATE WITH ARCHITECT. EXISTING 1 1/4"C FROM JUNCTION BOX IN HYBRID EQUIPMENT ROOM E2-425B TO CEILING PULLBOX IN HYBRID O.R. ROOM E2-427 FOR INTERFACING SYSTEMS, FIELD VERIFY. EXISTING 1"C FROM JUNCTION BOX IN HYBRID EQUIPMENT ROOM E2-425B TO CEILING SPACE IN HYBRID O.R. ROOM E2-427, FIELD VERIFY. EXISTING (2) 1"C FROM JUNCTION BOX UP TO CEILING SPACE ABOVE. PROVIDE BLANK COVER PLATE. RELOCATE EXISTING OUTLETS. SEE ET1-1 FOR NEW LOCATIONS. FIELD COORDINATE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

E2-435

OFFICE

E2-433

OFFICE

E2-431

OFFICE

E2-429

ORAL SURGERY

OFFICE

E2-333

RESIDENCY PROG

DIRECTOR

E2-331

ADMIN OFFICE

E2-329

TECH OFFICE

E2-411

ELEC

E-2-EC5

TEL/DATA

E2-TC5

CORRIDOR

E2-C36

TOILET

E2-432

TOILET

E2-430

LOCKERS

E2-426

CLEAN SUPPLY

E2-424

HOLD/MONITOR

E2-422A

PUMP/

ANESTHESIA

EQUIP

E2-421

SCRUB

E2-423

HYBRID CONTROL

E2-425A

HYBRID GEN

E2-425B

HYBRID OR

E2-427

B

C

D

A

14151617

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ELECTRICAL:

Gene Klow, AIA

(855) 521-1110 Alexandria, Virginia 22314 123 S Royal Street Concourse Federal Group

VAPAHCS Cath Lab Suite Upgrade

3801 Miranda Avenue, Palo Alto, CA

640-13-134

07/10/2020

100% - Bid Set

Revisions: Date:

Ed Wong, PE

(510) 763-7475 Oakland, California 94607 520 Third Street, Suite 206 F.W. Associates, Inc. Consulting Engineers

SJ JC

SHEET NOTES

ED1-4

N

2 2 4 6 8 100

FEETSCALE: 1/4" = 1'-0"

GENERAL NOTES

PARTIAL SECOND FLOOR

FIRE ALARM - EXISTING CONDITION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text +7'-4"

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(RR)

AutoCAD SHX Text (E)

AutoCAD SHX Text +7'-4"

AutoCAD SHX Text

(RR) PULLBOX ABOVE CEILING

AutoCAD SHX Text

(RR) PULLBOX ABOVE CEILING

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E)ABOVE CEILING

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(RR)

AutoCAD SHX Text (E)

AutoCAD SHX Text (R)

AutoCAD SHX Text

(RR)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(E)3/4"C (TYP.)

AutoCAD SHX Text (E)

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2020

AutoCAD SHX Text

AutoCAD SHX Text RELOCATE PULLBOX TO CLEAR FOR CEILING SUPPORT AND LIGHT FIXTURE. PROVIDE ACCESS PANEL AT CEILING FOR PULLBOX IN CEILING SPACE. RELOCATE EXISTING DEVICE TO NEW CEILING. COORDINATE WITH ARCHITECTURAL FOR NEW SUSPENDED CEILING. PROVIDE BLANK COVER PLATE. UTILIZE EXISTING FIRE ALARM CONDUIT SYSTEM FOR NEW FIRE ALARM DEVICE INSTALLATION.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. PROVIDE NEW PULLWIRE IN ALL PROVIDE NEW PULLWIRE IN ALL EXISTING CONDUIT.

(E) CORRIDOR

E2-C34

(E) CORR

E2-C32

SEMI-RESTRICTED

CORRIDOR

E2-C36

CLEAN SUPPLY

E2-424

LOCKERS

E2-426

TOILET

E2-432

TOILET

E2-430

HOLD/MONITOR

E2-422A

HOLD/MONITOR

E2-422B

PUMP/

ANESTHESIA

EQUIP

E2-421

TEL/DATA

E2-TC5

HAC

E2-412

CONTROL

E2-414

CT SCANNER

E2-453

EQUIP

E2-453A

CHIEF OFFICE

E2-437

OFFICE

E2-435

OFFICE

E2-433

OFFI…

This is the start of the file's text. The full file is on GovTribe.