- Z1DA--640-13-134 PAD Hybrid Cath Lab OR Upgrades
- Solicitation number
- 36C26121R0079
About this file
This notice provides details for an upcoming federal construction contract solicitation. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 intends to issue a Request for Proposal to complete construction of a new Catheterization Laboratory Hybrid Operating Room Suite and install a rooftop air handling unit at the VA Palo Alto Health Care System campus in Palo Alto, California. The construction period is 365 days with an anticipated solicitation release after November 4, 2021. The project value is between $5 million and $10 million. Offerors must be registered in the System for Award Management and have a current Online Representations and Certifications Application on file by the solicitation due date and award date. The North American Industry Classification System code for this project is 236220.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMP
321 4 5 6 7 8 9 10
BI
M
Pa lo A lto C at h
La b/
0-
-1
_A
.rv t
7/
/2
1:
:2
PM
GI001
COVER SHEET
Concourse Federal Group 123 S Royal Street Alexandria, VA 22314
Gene Klow, AIA
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020
100% - BID SET
SHEET INDEX
DEPARTMENT OF VETERNS AFFAIRS
UPGRADE CATH LAB SUITE, VAMC PALO ALTO
100% - BID SET
JULY 10, 2020
3801 MIRANDA AVENUE, PALO ALTO, CALIFORNIA
PROJECT 640-13-134
SITE MAPDESIGN TEAM
OWNER
ARCHITECT / CONTRACT PRIME
STRUCTURAL ENGINEER
ELECTRICAL ENGINEER
MECHANICAL / PLUMBING ENGINEER
Veterans Association VA Palo Alto Healthcare System Contact: Wes Chow, AIA
Concourse - MEI SFVOSB JV, LLC 123 S Royal Street Alexandria, Virginia 22314 Contact: Matt Shuba, AIA mshuba@concoursefederal.com
(202) 304-9784
Gregory P. Luth & Associates 3350 Scott Boulevard, Building 48 Santa Clara, California 95054 Contact: Greg Luth, PE greg@gplainc.com
(408) 654-0475
F.W. Associates, Inc.
520 3rd Street, Suite 206 Oakland, California 94607 Contact: Munson Fong mfong@fwa-inc.com
(510) 763-7475
Capital Engineering Consultants 11020 Sun Center Drive, Suite 100 Rancho Cordova, California 95670 Contact: Bryan Johnson bjohnson@capital-engineering.com
(916) 851-3500
3801 MIRANDA AVENUE
PALO ALTO, CALIFORNIA
ADD CONSTRUCTION LAY-DOWN
AREA AND ACCESS ROUTES
13 - ELECTRICAL
E0-1 SYMBOL LEGEND, ABBREVIATIONS, GENERAL NOTES
E0-2 OVERALL FIRST FLOOR - REFERENCE PLAN
E0-3 PARTIAL SECOND FLOOR PLAN
ED1-1 LIGHTING - EXISTING CONDITION
ED1-2 POWER - EXISTING CONDITION
ED1-3 TELECOM - EXISTING CONDITION
ES1-4 FIRE ALARM - EXISTING CONDITION
EL1-1 SECOND FLOOR LIGHTING
EP1-1 SECOND FLOOR POWER
EP1-2 ROOF POWER
EM1-1 SECOND FLOOR HVAC POWER
ET1-1 SECOND FLOOR TELECOM
ET2-1 DETAILS AND DIAGRAMS
ET2-2 DETAILS AND DIAGRAMS
EF1-1 SECOND FLOOR FIRE ALARM
E5-1 SINGLE LINE DIAGRAM
E6-1 PANEL AND MECHANICAL EQUIPMENT SCHEDULES
E6-2 PANEL SCHEDULES
E7-1 DETAILS AND DIAGRAMS
14 - MECHANICAL
MH001 MECHANICAL COVER SHEET
MH002 MECHANICAL SCHEDULES
MH003 MECHANICAL SCHEDULES
MH004 MECHANICAL SCHEDULES
MD102 SECOND FLOOR DEMO HVAC PLAN
MH102 SECOND FLOOR HVAC PLAN
MH103 THIRD AND FOURTH FLOOR HVAC PLANS
MH105 PARTIAL ROOF HVAC PLAN
MH402 PARTIAL SECOND FLOOR HVAC ZONING
MH403 EXHAUST AIR VALVE ZONING
MP102 SECOND FLOOR PIPING PLAN
MP104 PARTIAL FOURTH FLOOR PIPING PLAN
MH501 MECHANICAL DETAILS
MH502 MECHANICAL DETAILS
MH503 MECHANICAL DETAILS
MH504 MECHANICAL DETAILS
MH601 MECHANICAL RISER DIAGRAMS
MI701 MECHANICAL CONTROLS
MI702 MECHANICAL CONTROLS
MI703 MECHANICAL CONTROLS
15 - EQUIPMENT
EQ101 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
EQ102 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
EQ201 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
EQ202 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
EQ203 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
EQ301 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
EQ302 EQUIPMENT VENDOR'S DWGS - FOR COORDINATION USE
01 - GENERAL
GI001 COVER SHEET
GI002 PROJECT INFORMATION, NOTES + SYMBOLS
GI003 FIRE, LIFE SAFETY + EGRESS DIAGRAMS
GI004 ACCESSIBILITY REQUIREMENTS
07 - STRUCTURAL
S001 GENERAL NOTES, SHEET LIST, LEGEND & TYPICAL DETAILS
SS101 FLOOR 2 FRAMING PLAN
SS103 FLOOR 3 AND 4 FRAMING PLAN
SS105 ROOF FRAMING PLAN
SS301 BUILDING SECTIONS
SS302 CLEANSUITE SECTIONS
SS701 DETAILS
SS702 DETAILS
08 - ARCHITECTURE
AD101 FLOOR 2 DEMOLITION PLAN
AD102 FLOOR 3 AND 4 DEMOLITION FLOOR AND CEILING PLANS
AD401 ENLARGED HYBRID OR DEMOLITION PLAN
AS101 FLOOR 2 PARTITION PLAN
AS102 FLOOR 2 REFLECTED CEILING PLAN
AS103 FLOOR 3 AND 4 PARTITION AND REFLECTED CEILING PLANS
AS105 ROOF PLAN
AS302 HYBRID OR SUITE SECTIONS
AS401 ENLARGED HYBRID OR PARTITION PLAN
AS402 ENLARGED HYBRID OR REFLECTED CEILING PLAN
AS403 ENLARGED HYBRID OR FINISH PLAN
AS404 ENLARGED HYBRID OR EQUIPMENT PLAN
AS406 ELEVATIONS - HYBRID OR, HALLWAY, LOCKER + TOILET
AS407 ELEVATIONS - SUPPLY, HOLD MON, HYBRID CONT, GEN, SCRUB
AS501 EXTERIOR DETAILS
AS502 INTERIOR DETAILS
AS503 CASEWORK SECTIONS + DETAILS
AS504 CEILING AND SOFFIT DETAILS
AS601 DOOR + WINDOW SCHEDULES
AS602 PARTITION SCHEDULE
AS603 MEDICAL EQUIPMENT SCHEDULE
AS606 SIGNAGE SCHEDULE AND PLAN
AS607 SIGN TYPE DETAILS
AS608 SIGN TYPE DETAILS
AS609 SIGN TYPE DETAILS
AS701 PARTITION DETAILS
AS702 PROTECTIVE BARRIER AND LEAD LINED DETAILS
11 - FIRE PROTECTION
FP001 FIRE PROTECTION SYMBOLS, NOTES AND ABBREVIATIONS
FPD102 FIRE PROTECTION PARTIAL SECOND FLOOR DEMO PLAN
FP102 FIRE PROTECTION PARTIAL SECOND FLOOR NEW PLAN
12 - PLUMBING
PL001 PLUMBING SYMBOLS, ABBREVIATIONS AND LEGENDS
PL002 PLUMBING EQUIPMENT SCHEDULES
PD101 FIRST FLOOR PLUMBING DEMO PLAN
PL101 FIRST FLOOR WASTE & VENT NEW PLAN
PD102 SECOND FLOOR PLUMBING DEMO PLAN
PL102 SECOND FLOOR PLUMBING NEW PLAN
PL104 PARTIAL FOURTH FLOOR PLUMBING PLAN
PL105 PARTIAL ROOF PLUMBING PLAN
PG102 PARTIAL SECOND FLOOR MED GAS PLAN - NEW & DEMO
PL501 PLUMBING DETAILS
PL601 PLUMBING DIAGRAMS
Revisions: Date:
TYP.
THRES
S.
RM
RH
REINF
REQD
REF
STD
SIM
SHR
THK
TB
T.C.
TEL
STOR
STRUCL
STL
NIC
NO or #
N.T.S.
N.R.
OPNG
OPP
OF/CI
OA
OC
PLYWD
PT.
PL.
QTY
PTN
VERT
VIF
WC
WD
W/O
W W/
WP
N UON
CEM
DWG
CONC
CONT.
CORR
CPT
CSK
CNTR
CLG
CLO.
CLR
CER
DET
DIA
DIM
DN.
DR
CTR
ADJ
AFF
ARCH
(N)
AB
ADDL
(E)
BLKG.
BM
BOT.
CAB
BD
BLDG
MTD
INC.
INFO
HT
INT
JT.
INSUL
HC
MIN
MISC
MAX
KIT
LAB
EA
EQ
EXT
FA
FD
FDTN
FIN
FIXT
EL
FPRF.
FLUOR
FOF
FOS
FLR
E
L
ACOUST.
ACS PNL
BKG.
BLK.
CG
CJ
COL
CONSTR
DISP
EJ
ELEC.
ELEV
ENCL
ENGR
E.P.B.
EQUIP
EXP
EWC
FE
FEC
FHC
FT
F.S.
HDWD
HM
HORIZ
HR.
I.D.
LAM
LT
MATL
MECH
MTL
MFR
NOM
OD
OFF
OPH
PLAM
PR
PTD
R
REFR.
REG
RESIL
RO
SCHED
SECT
SHT
SC
SPEC
SQ
SST
SUSP
T.P.B.
VEST
W.O.
WT
W.R.
M.D.F.
(RL)
C.O.
EXP BT
EMER
EXIST
HDW
GYP
GA
GALV
GB
GL
Vertical
Wood
West With
Unless Otherwise Noted
Verify In Field
Without
Water Closet
Waterproofing
Typical
Threshold
Right Hand was Robe Hook
Top of Curb
Reinforce Required
Room
Reference
Standard
Similar
Shower
South
Storage
Towel Bar
Telephone
Structural
Thickness
Steel
Not In Contract
Not To Scale
Owner Furnished Contractor Installed
Number
On Center
Opening Opposite
Overall
Non Rated
Plywood
Partition
Quantity
Point
Plate
North
Cement
Drawing Mounted
Ceiling Closet Clear
Concrete
Continuous
Corridor
Ceramic
Carpet
Countersunk
Counter
Detail Diameter Dimension
Down Door
Center
Insulation
Height
Incandescent
Information
Hollow Core
Interior
Joint
Maximum
Minimum
Kitchen
Laboratory
Miscellaneous
Each
At Centerline
Existing New
Adjustable
Architectural
Board
Building
Blocking Beam
Anchor Bolt
Additional
Bottom
Cabinet
Above Finished Floor
Equal
Exterior
Elevation
Finish
Fixture
Fire Alarm Floor Drain Foundation
Fluorescent Face of Finish Face of Studs Fireproof
Floor
And
East
Diameter
Angle
Acoustical
Access Panel
Backing
Block
Corner Guard Construction Joint
Column
Construction
Dispenser
Expansion Joint
Electrical Elevator
Enclosure Engineer Electrical Panelboard
Equipment
Expansion Electric Water Cooler
Fire Extinguisher Fire Extinguisher
Fire Hose Cabinet
Foot or Feet Floor Sink
Hardwood
Hollow Metal Horizontal Hour
Inside Diameter
Laminate
Light
Material
Mechanical
Metal
Manufacturer
Nominal
Outside Diameter
Office Opposite Hand
Plastic Laminate
Pair
Paper Towel Dispenser
Radius
Refrigerator Register
Resilient
Rough Opening
Schedule Section
Sheet
Solid Core
Specification Square
Stainless Steel
Suspended
Telephone Panelboard
Vestibule
Where Occurs
Weight Water Resistant
Medium Density
Relocated Existing
Pound or Number
Cased Opening
Expansion Bolt
Emergency
Existing
Hardware
Gypsum
Gauge Galvanized Grab bar Glass
Cabinet
Fiberboard
CSR Controlled Substance Room
E.M.R. Elevator Machine Room
IT Information Technology
OCR. Oxygen Cylinder Refill
MPOE Minimum Point of Entry
MCI. Mass Casualty Incident
CQI
Continuous Quality Improvements
S.E.D. See Electrical Drawings
S.S.D. See Structural Drawings
S.C.D. See Civil Drawings
S.L.D. See Landscape Drawings S.LV.D. See Low Voltage Drawings S.M.D. See Mechanical Drawings S.P.D. See Plumbing Drawings
CMU Concrete Masonry Unit
FIN FLR Finish Floor
GYP BD Gypsum Board
ALUM Aluminum
COORD Coordinate
CT Ceramic Tile
CONTR Contractor
DBL Double DEMO Demolition
INCL Included
LKR RM Locker Room
NA Not Applicable
OVRHD. Overhead
PNL Panel
RD Roof Drain
REV Revision
S.A.B.
S.A.F.B.
Sound Attenuation Blanket Sound Attenuation Fire Blanket
SUSP CLG Suspended Ceiling
TOC Top of Curb
TBD To Be Determined
UCD Under Cut Door
CONCRETE
EARTH
GYPSUM BOARD
BATT INSULATION
RIGID INSULATION
MEDIUM DENSITY FIBERBOARD
ALUMINUM
STUCCO
PLYWOOD
WOOD
PLASTER
STEEL
OFFICE
A-211
A
INTERIOR ELEVATION(S)
NOT SHOWN.)
SHEET WHERE ELEVATION IS
NO ARROWS MEANS ELEVATION
(UNFOLD ELEVATIONS CLOCKWISE
ELEVATION IDENTIFICATION
DRAWN.
DOOR SYMBOL
DOOR MARK
DRAWING NUMBER
DISCIPLINE PREFIX
SHEET WHERE DETAIL IS DRAWN.
DETAIL IDENTIFICATION
DETAIL
ROOM IDENTIFICATION
5-1
9-1
ROOM NAME
ROOM NUMBER
(E) COLUMN LINE W/
COLUMN DESIGNATIONS
REVISION
CLOUD AROUND REVISION
DIMENSION LINES
CENTERLINE OF
COLUMN OR STUD
FACE OF FINISH
OPTIONAL
B1
TYPICAL FURRING OR
PARTITION TYPE, SEE SHEET
A6-2
GROUP NUMBER
1.1 WINDOW TYPE
3-1 SHEET WHERE DETAIL IS DRAWN.
SECTION IDENTIFICATION
SECTION
TYPICAL PARTITION
2x2 DIFFUSERS, SUPPLY
2x2 REGISTER OR RETURN
CORNER GUARD
A
(N) COLUMN LINE W/
COLUMN DESIGNATIONS
FEC
1-HOUR RATED FIRE ASSEMBLY
1-HOUR RATED SMOKE ASSEMBLY
OVERHEAD LINES
FIRE EXTINGUISHER CABINET
SINGLE SHADE SYSTEM
DOUBLE SHADE SYSTEM
CENTERLINE OF OPENING
CENTERLINE OF OPENING
DOOR TO BE DEMOLISHED
(E) DOOR TO REMAIN
(N) DOOR
(E) COLUMN TO HAVE
FURRING REMOVED FOR
(N) CONNECTIONS,
COLUMN TO REMAIN
(E) COLUMN AND (E)
FURRING TO REMAIN
SPOT ELEVATION
EXISTING WALL / PARTITION /
FURRING TO REMAIN
EXISTING WALL OR PARTITION
TO BE REMOVED
EXISTING WALL FINISHES OR
CLADDING TO BE REMOVED,
STRUCTURE OF WALL TO
REMAIN
AREA NOT IN SCOPE OF
WORK
2x4 REGISTER OR RETURN
2x4 DIFFUSERS, SUPPLY
DOWNLIGHT
EXISTING PARTIALLY-
CONSTRUCTED PARTITION TO
BE COMPLETED PER
PARTITION TYPE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMP
321 4 5 6 7 8 9 10
BI
M
Pa lo A lto C at h
La b/
0-
-1
_A
.rv t
7/
/2
1:
:2
PM
GI002
PROJECT INFORMATION, NOTES +
SYMBOLSConcourse Federal Group
123 S Royal Street Alexandria, VA 22314
Gene Klow, AIA
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020
100% - BID SET
1. These documents have been prepared based on information provided by others. It is the responsibility of the GC to verify all field conditions and report any discrepancies to the architect and COR prior to commencing work.
2. The construction hours shall be Monday through Friday from 4:30pm to 7:30am, Saturday and Sunday all day unless otherwise noted. VA staff to be present at all times. Failure to meet this schedule will result in damages of $1000 per day.
3. Contractor shall be responsible for completing all work in compliance with applicable codes and regulations.
4. Do not scale drawings, contractor shall verify all dimensions and existing conditions prior to the start of work and shall notify the owner and architect of any discrepancies prior to proceeding with the work.
5. Contractor shall be responsible for assuring that all necessary permits and approvals are obtained prior to beginning work.
6. If a conflict exists when the contract documents and a regulatory requirement, the contractor shall comply with the more stringent or restrictive requirement. If a conflict exists between the drawings and the specifications, the more stringent requirement shall take precedence.
7. Locations of all utility lines (ducts, pipes, conduits, and other overhead obstructions) shown are approximate. Coordinate all support systems so as to not interfere with each other. Provide additional bracing as necessary to complete the installation at no increase to the contract sum.
8. Provide supports and bracing as required for existing structure, utilities, pipes, ducts, conduit etc., during demolition and new construction work where existing supports are removed due to work under this contract. New supports shall meet current code requirements.
9. Contractor shall provide complete design-build service for the fire alarm system. Provide separate shop drawings for fire alarm system, submit fire alarm submittal including shop drawings and product data to owner and architect for review and approval prior to installation. Provide listing number for all components in submittal.
10. Contractor shall provide complete design-build service for the fire sprinkler system. Provide separate shop drawings for fire sprinkler system, submit sprinkler system submittal including shop drawings, product data, hydraulic calculations, etc. To the owner and architect for review and approval prior to installation. Sprinkler system shall be designed in accordance with Title 24, CCR Part 2, Chapter 38 and NFPA 13, 2019 edition. At acoustical ceiling locations, locate all sprinkler heads at center of ceiling tiles, unless otherwise noted.
11. In all construction areas, seal all penetrations such as ducts, conduit, pipes, etc. at fire resistive rated partitions and floor/ceiling assemblies, whether shown or not, at no change to the contract sum. Use sealant type to maintain proper fire resistive rating of the penetrated assemblies. All penetrations at fire resistive rated partitions or floor/ceiling assemblies shall be in accordance with the appropriate UL listed approved systems.
12. If contractor proposed alternate construction details from those presented by the architect, contractor shall be responsible for all costs and time delays resulting from the contractor's proposed alternate construction details which affect other parts of the work or the work of separate contractors.
13. Contractor shall protect all existing construction and existing life/safety construction not included in this contract. The contractor shall be responsible for the repair and restoration of such construction to the original condition at no additional cost to the owner.
14. Any scheduled power or data downtime, regardless of hour or day, must be coordinated with the contracting officer's representative (COR) and the campus facility management department (FMD) not less than 30 days in advance.
15. Construction for this project will take place in buildings that remain occupied by VAMC staff and patients. Dust control, noise, and vibration are areas of major concern. The contractor will be required to maintain airtight dust barriers and exhaust fans during the duration of dust producing work as specified and directed by the resident engineer. See Specification, Section 01 00 00, Article 1.7, Alterations for additional information. Work that creates excessive noise and/or vibrations must be carefully scheduled and coordinated with the hospital. There will be times when noise or vibration producing work will not be allowed and it will have to be scheduled for other non-critical times.
16. The contractor is responsible for constructing and maintaining all required barriers. Temporary fire barriers must be constructed for all occupancies wherever construction lowers the fire safety features of the area being remodeled (i.e. Fire sprinklers or fire alarm systems are impaired or removed), corridors are closed off or corridor walls are removed, or whenever firewalls are impacted. Fire walls are also required to separate new construction from existing buildings. Temporary fire walls that separate renovation projects from occupied areas must be of 1-hour construction with one (1)-hour rated doors. Temporary fire walls that separate new construction from occupied areas must be two (2)-hour rated with ninety (90) minute rated doors. Temporary rated partitions must run from slab to slab and from exterior wall or fire rated partition to exterior wall or fire rated partition.
17. The VA requires that all penetrations through fire rated barriers be accomplished by a qualified firestop contractor in accordance with section 07 84
00. When work takes place within existing building that are not separated by a 2-hour barrier from occupied areas, and where it is not feasible to have a qualified firestop contractor providing fire sealing on a daily basis, it shall be the responsibility of the trade penetrating the fire rated barrier to provide temporary fire protection of all penetrations at the end of each work day. Temporary protection must meet all NFPA codes related to fire barrier penetrations. The temporary protection must be maintained in proper order until the permanent fire stopping material is installed. Firebricks or fire plugs must be used to seal penetrations in temporary or permanent fire separations (floors and walls) until they can be properly fire sealed (i.g.
Core drills for new sewer lines prior to installation and fire stopping of sewer lines).
18. The contractor shall separate all construction areas from the rest of the building’s normal operation. This shall include the erection of clearly marked barricades to limit access by unauthorized personnel, and to prevent contamination from particulate matter. If a fire barrier is not required, then a solid barrier constructed of metal studs and sheetrock on one side shall be used. The barrier must prevent the transmission of dust by sealing the wall to the floor and ceiling and sealing all joints or by some other method. The exception to a solid barrier is if a fire wall is not required and the expected duration of the temporary barrier will not exceed 7 calendar days. In this situation, a plastic temporary barrier may be used. If a plastic barrier is used, it must be inspected daily to assure its integrity. When plastic sheeting is used, fire resistant plastic sheeting (limited combustibility) must be used. All necessary cautionary signage will be in accordance with federal regulation 29CFR 1926.200.
19. The ceiling space from the bottom of the ceiling grid to a minimum of 6” above the bottom of the ceiling grid is reserved for installation of ceiling mounted items (i.e. Light fixtures, speakers, diffusers). No piping, ductwork, conduits, etc., except drops serving the ceiling mounted items, is allowed to be installed in this space, unless otherwise approved by the resident engineer.
20. Contractor is required to follow all OSHA regulations concerning construction. The superintendent is required to have completed, as a minimum, OSHA’s 10-hour training and be knowledgeable of general safety requirements for confined spaces, fall protection, personal protective equipment, trenching, scaffolding, cranes, electrical, etc. Applicable subcontractors are to have a competent person on site when required by OSHA. If accessing a confined space, the contractor is required have their own confined space air monitor and to test the air prior to entering any confined space. If the contractor must enter a sanitary sewer manhole, in addition to a confined space air monitor, they must have proper OSHA rescue equipment for a permit required confined space. Where it is not possible for the VA to shutdown an electrical panel or circuit, the contractor must provide and use the appropriate safety clothing and equipment as required by NFPA 70E. The VA will be monitoring the contractor’s compliance with OSHA regulations. Failure to comply is grounds for stopping work.
ADDRESS: 3801 MIRANDA AVENUE
BUILDING 100
PALO ALTO, CA 94304
BUILDING HEIGHT: TOP OF PARAPET: 77'-0"
OCCUPANCY GROUP: AMBULATORY HEALTH CARE
CONSTRUCTION TYPE: TYPE I-B
FIRE PROTECTION: FULLY SPRINKLERED
NO. OF STORIES: 4 FLOORS AND 1 BASEMENT
PREVAILING CODES: NFPA 101 LIFE SAFETY CODE (2018 EDITION)
INTERNATIONAL BUILDING CODE (2018 EDITION)
INTERNATIONAL ENERGY CONSERVATION CODE (2018 EDITION)
AMERICANS WITH DIASBILITIES ACT OF 2010 STANDARDS FOR ACCESSIBLE DESIGN
ICC A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (2019 EDITION)
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (2019 EDITION)
Project scope includes completing construction of one hybrid operating room, control room, and support spaces on the second floor of building 100. The project was partially constructed and has been halted while the documents are updated.
The original “Phase 3” work proposed for the cath lab has been removed from the project scope and is proposed to be performed as a turnkey equipment replacement project by the VA. This project will provide an HVAC point of connection.
No change of use or construction type proposed
MATERIALS
SYMBOLS ABBREVIATIONS GENERAL NOTES PROJECT DESCRIPTION
PROJECT DATA
UP
FEC
FIRE EXTINGUISHER CABINET
EXIT PATH
EXIT W/ NO. OF OCCUPANTS
1-HOUR SMOKE PARTITION
1-HOUR FIRE PARTITION
2-HOUR FIRE PARTITION
NOT IN SCOPE OF WORK
BUSINESS USE GROUP
150 SF PER OCCUPANT
INPATIENT TREATMENT DEPARTMENTS
240 SF PER OCCUPANT
1213141516
B
C
D
E
F
A
EXIT
DISCHARGE B
CHIEF OFFICE
E2-437
OFFICE
E2-435
OFFICE
E2-433
OFFICE
E2-431
OFFICE
E2-429
ORAL SURGERY
OFFICE
E2-333
RESIDENCY PROG
DIRECTOR
E2-331
ADMIN OFFICE
E2-329
(E) CORR
E2-C32
(E) CORRIDOR
E2-C34
RESTRICTED
HALLWAY
E2-C33
PUMP/
ANESTHESIA
EQUIP
E2-421
HYBRID CONTROL
E2-425A
HYBRID GEN
E2-425B
HOLD/MONITOR
E2-422B
HOLD/MONITOR
E2-422A
CLEAN SUPPLY
E2-424
LOCKERS
E2-426
TOILET
E2-432
TOILET
E2-430
HYBRID OR
E2-427
SEMI-RESTRICTED
CORRIDOR
E2-C36
CT SCANNER
E2-453
CONTROL
E2-414
CATH LAB
E2-410
TECH OFFICE
E2-411
ELEC
E-2-EC5
TEL/DATA
E2-TC5
HAC
E2-412
TMT 11
E2-349
TMT 10
E2-347
TMT 09
E2-345
CLRM
E2-341
CHIEF
E2-327
CORR
E2-C21
SCRUB
E2-423
(E) CORR
E2-C32
(E) STAIRWAY
ST-2
ST
EXIT
DISCHARGE A
STAIRWAY
ST-3
ST3
POINT A
POINT B
TRAVEL DISTANCE TO CORRIDOR = 92' - 9"
TR
AV
EL
D
IS
TA
N C
E
TO
C O
R R
ID
O
R
2'
4"
EQUIP
E2-453A
(E) CLEAN LINEN
E2-459
TEMPORARY
CLEAN SUPPLY
ROOM
E2-455
(E) OFFICE
E2-457
(E) OFFICE
E2-456
(E) CATH LAB
E2-454 (E) OFFICE
E2-458
(E) OFFICE
E2-460
CATH GEN. EQUIP
E2-410B
(E) OFFICE
E2-462
(E) ECG EXAM
E2-401
(E) ECG WORK
E2-403
(E) MECH SHAFT
M-7.2
(E) MECH SHAFT
M-2
(E) TMT 15
E2-351
(E) DENTURES
E2-360D
(E) BURNOUT
E2-360E
(E) PROS LAB
E2-360
(E) CORR
E2-C22
(E) PREP
E2-330
(E) STER
E2-340
(E) STORAGE 01
E2-342
(E) TMT 13
E2-344
(E) CART LIFT
C-2
(E) PAT. TOILET
E2-346
(E) DARK
E2-350
(E) STORAGE 01
E2-360C
(E) PLASTER
E2-360B
(E) PORCELAIN
E2-360A
(E) ORAL SURG 2
E2-323
(E) ORAL SURG 1/
TRNG
E2-325
(E) HAC
E2-348
(E) CORR
E2-C23
(E) CORR
E2-C30
(E) RECVY
E2-321
(E) TMT
E2-318
(E) TMT
E2-C316
(E) TMT
E2-314
(E) TMT
E2-312
(E) TMT
E2-310
(E) X-RAY
E2-308
(E) X-RAY
E2-306
(E) ORAL SURG 3
E2-319
TRAVEL DISTANCE TO EXIT = 198' - 8"
TR
AV
EL
D
IS
TA
N C
E
TO
E
XI
T
7'
5"
FEC
FEC
KEY PLAN
N
VA PALO ALTO HEALTHCARE SYSTEM
3801 Miranda Avenue Palo Alto, CA 94304
FLOOR 2
OCCUPANCY
OCCUPANCY TYPES FOR THE AREA OF WORK INCLUDE BUSINESS AND
INPATIENT TREATMENT DEPARTMENTS. SEE HATCHES IN EGRESS LEGEND.
BUSINESS USE:
3227 SQUARE FEET AT 150 SF / OCCUPANT
22 OCCUPANTS
INPATIENT TREATMENT DEPARTMENT USE:
1103 SQUARE FEET AT 240 SF / OCCUPANT
5 OCCUPANTS
TOTAL OCCUPANT LOAD 27 OCCUPANTS (NFPA 101 TABLE 7.3.1.2)
EGRESS
THERE IS NO PROPOSED CHANGE OF EGRESS. PRIMARY EXIT DISCHARGES
FOR AREA OF WORK ARE 'EXIT DISCHARGE A' AND 'EXIT DISCHARGE B.'
EXIT DISCHARGE A:
DOOR ST-3: 36" WIDE, 180 CAPACITY
STAIRWAY ST-3: 44" WIDE, 146 CAPACITY
EXIT DISCHARGE B:
DOOR ST-2: 36" WIDE, 180 CAPACITY
STAIRWAY ST-2: 44" WIDE, 146 CAPACITY (NFPA 101 TABLE 7.3.3.1)
COMMON PATH OF TRAVEL FROM POINT A: 35' - 10"
COMMON PATH OF TRAVEL FROM POINT B: 48' - 7"
MAXIMUM COMMON PATH OF TRAVEL: 100 FT (NFPA 101 21.2.5..3.1)
DISTANCE FROM POINT A EXIT C: 198' - 8"
DISTANCE FROM POINT B TO EXIT B: 197' - 5"
MAXIMUM EXIT TRAVEL DISTANCE: 200' - 0" (NFPA 101 21.2.6.2)
CODE ANALYSIS
1. AREA OF WORK IS FULLY SPRINLERED PER NFPA 13. SEE FIRE
PROTECTION SHEET FP001 FOR MORE INFROMATION.
2. AREA OF WORK IS FULLY ALARMED PER NFPA 72. SEE FIRE
PROTECTION SHEET FP001 FOR MORE INFORMATION AND EF1-1 FOR
ALARM LOCATIONS .
3. SEE SHEET EL1-1 FOR EXIT SIGN LOCATIONS.
FIRE SAFETY NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMP
321 4 5 6 7 8 9 10
BI
M
Pa lo A lto C at h
La b/
0-
-1
_A
.rv t
7/
/2
1:
:3
PM
GI003
FIRE, LIFE SAFETY + EGRESS
DIAGRAMSConcourse Federal Group
123 S Royal Street Alexandria, VA 22314
Gene Klow, AIA
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020
100% - BID SET
5 5 10 15 20 1/8" = 1'-0"
FEETSCALE
EGRESS LEGEND
3'
0"
COAT HOOK /
TOWEL PIN
PAPER TOWEL
DISPENSER (VC)
LAVATORY
SOAP DISPENSER (VC)
3'
4" M
AX
4"
3'
4"
1' - 6"
3'
0"
TY
P .
1'
6"
2"
O
PE
R
AT
IN
G
D
EV
IC
E
FO
R
AC
C
ES
SI
BL
E U
N
IT 2"
1' - 6"
CL
3'
4" M
AX
O
PE
R
AT
IN
G
D
EV
IC
E
FO
R
AC
C
ES
SI
BL
E U
N
IT
2'
3" 3'
4"
CL
CL
3'
4"
H
AN
D
LE
PU
LL
R
IN
G
AL
AR
M P
AN
EL
MIRROR
F.E.C. / MED GAS VALVE
BOX / AREA ALARM
PANEL
6'
8"
3'
6"
4'
0"
4"2"
THERMOSTAT
LIGHT SWITCH
ELEC. RECEPTACLE /
TELEPHONE OUTLET /
JUNCTION BOX
STROBE / HORN ELEC.
RECEPTACLE
COUNTERTOP
TOILET SEAT COVER
DISPENSER (VC)
NURSE CALL WITH PULL CORD
TOILET PAPER DISPENSER (VC)
GRAB BAR
2"
DOOR/ EXIT LIGHT
CL
FINISH FLOOR
TOP OF SEAT
TOP OF GRAB BAR
2"
1'
7"
CRASH RAIL /
BUMPER RAIL
NOTE:
THE 30" X 48" WHEELCHAIR CLEAR FLOOR SPACE IS
LOCATED A MAX 10" FROM THE WALL
NOTE:
IF THE DEPTH OF THE OBSTRUCTION IS 24" AND
THE MAXIMUM HEIGHT OF THE OBSTRUCTION IN
34", THE MAXIMUM HIGH SIDE REACH OVER THE
OBSTRUCTION IS 46".
NOTE:
THE 30" X 48" WHEELCHAIR CLEAR FLOOR SPACE IS
LOCATED A MAX 10" FROM THE WALL
NOTE:
X SHALL BE ≤ 25"; Z SHALL BE > X, WHEN X < 20", THEN Y SHALL BE 48" MAXIMUM.
WHEN X IS 20-25", THEN Y SHALL BE 44" MAXIMUM.
THE MAXIMUM LEVEL FORWARD REACH OVER AN OBSTRUCTION WITH KNEE SPACE BELOW IS 25".
WHEN THE OBSTRUCTION IS LESS THAN 20" DEEP, THE MAXIMUM HIGH FORWARD REACH IS 48".
WHEN THE OBSTRUCTION PROJECTS 20-25", THE MAXIMUM HIGH FORWARD REACH IS 44".
Z
X =
Y
Z
X
Y
10" MAX30"
FACE OF SWITCH OR
RECEPTABLE COVER PLATE
FACE OF SWITCH OR
RECEPTABLE COVER PLATE
30" 10" MAX
FACE OF SWITCH OR
RECEPTABLE COVER PLATE
30" > 10-24" MAX
FACE OF SWITCH OR
RECEPTABLE COVER PLATE
FACE OF SWITCH OR
RECEPTABLE COVER PLATE
48" 48"
There are no construction tolerances allowed for accessibility dimensions. The dimensions shown in these diagrams are face of finish. The diagrams are provided to assist the contractor in providing these required accessibility dimensions that cannot be changed by otherwise acceptable construction tolerances.
GENERAL ACCESSIBILITY NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMP
321 4 5 6 7 8 9 10
BI
M
Pa lo A lto C at h
La b/
0-
-1
_A
.rv t
7/
/2
1:
:3
PM
GI004
ACCESSIBILITY REQUIREMENTS
Concourse Federal Group 123 S Royal Street Alexandria, VA 22314
Gene Klow, AIA
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020
100% - BID SET
1/4" = 1'-0"
TYPICAL MOUNTING HEIGHTS
1/2" = 1'-0"
1 MANEUVERING CLEARANCES @ MANUAL SWINGING DOORS
1/2" = 1'-0"
2 MANUEVERING CLEARANCE APPROACHES
1/2" = 1'-0"
3 MAXIMUM REACH HEIGHTS
Te kl a St ru ct ur es
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
S001
GENERAL NOTES, SHEET LIST,
LEGEND, & TYPICAL DETAILS
Ω
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
Te kl a St ru ct ur es
SS101
FLOOR 2 FRAMING PLAN
FLOOR 2 FRAMING PLAN
SCALE = 1:641
DD
A
C
A
15 14
B
141516
B
C
KEY PLAN
N
VA PALO ALTO HEALTHCARE SYSTEM
3801 Miranda Avenue Palo Alto, CA 94304
FLOOR 2
FEETSCALE
3/16" = 1'-0"
5 0 5 10 15 20
REQUIREMENTS EXCEED THIS LIMIT).
SPECIFICATIONS, TYP. ( 12/ " MAX DERESSION, NOTIFY SEOR IMMEDIATELY IF FLOOR
DEPTH, LAYOUT, AND LEVELNESS REQUIREMENTS AS INDICATED IN GE DRAWINGS AND
IN (E) CONCRETE SLAB ON GRADE AS REQ'D FOR CONFORMANCE WITH GE MONOPOUR
5. INDICATES EXTENT OF DEPRESSED SLAB. GC SHALL GRIND SMOOTH AND/OR FILL
4. SEE AS603 FOR EQUIPMENT AND ATTACHMENT DETAILS.
AND LOCATIONS OF EQUIPMENT ATTACHMENT WITH ALL TRADES DRAWINGS.
3. SEE AS404 FOR EQUIPMENT LOCATIONS. GC TO COORDINATE ALL DIMENSIONS
WITH DIMENSIONS SHOWN.
IMMEDIATELY IF THERE ARE ANY DISCREPANCIES OF CONFLICTS
2. GC SHALL FIELD VERIFY ALL DIMENSION. NOTIFY THE ARCHITECT
WHICH ARE APPLICABLE TO ALL DRAWINGS, UNO.
1. SEE SHEET SS001 FOR GENERAL NOTES, SHEET LIST, LEGEND & TYPICAL DETAILS,
SHEET NOTES:
W
X
(E ) B
M
W
X
(E ) B
M
W16X36
(E) BM
SEE SHEET NOTE 5.
W18X60
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W16X31
(E) BM
W18X60
(E) BM
H
SS
X1
(E
) B R
AC
E
W
X
(E ) B
M
W
X
(E ) B
M
W10X26
(E) BM
W16X31
(E) BM
'-0
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W18X60
(E) BM
W18X60
(E) BM
W18X60
(E) BM
W18X60
(E) BM
W21X166
(E) BM
W18X71
(E) BM
W18X65
(E) BM
W18X65
(E) BM
W21X147
(E) BM
W
X
(E
) B M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M W
X
(E
) B M
W
X
(E ) B
M W
X
(E
) B M
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W16X31
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W10X26
(E) BM
W8X18
(E) BM
W 8X
(E
) B M
W10X26
(E) BM
W
X
(E ) B
M
W10X26
(E) BM
W10X26
(E) BM
W10X26
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W18X71
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W18X65
(E) BM
W18X65
(E) BM
W18X71
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W16X31
(E) BM
W16X31
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W8X18
(E) BM
W10X26
(E) BM
W14X159
(E) COL
W14X159
(E) COL
W14X211
(E) COL
W14X159
(E) COL
HSS12X12
(E) BRACE
HSS12X12
(E) BRACE
HSS12X12
(E) BRACE
H
SS
X1
(E
) B R
AC
E
H
SS
X1
(E
) B R
AC
E
26'-0"26'-0"26'-0"
'-0
'-0 a St ru ct ur es
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
SS103
FLOOR 3 AND 4 FRAMING
PLAN
FLOOR 3 PARTIAL PLAN
SCALE = 1:482 FLOOR 3 FRAMING PLAN
SCALE = 1:961
FLOOR 4 PARTIAL PLAN
SCALE = 1:484
FLOOR 3 PARTIAL PLAN - CLEANSUITE PLAN
SCALE = 1:483
B
A
B
A
D
C
AA
1517 1415
BB
A
17 16
B
A
B
D
D
C
C
V.I.F.
V.
I.F
V.
I.F
V.I.F.
AND LOCATIONS OF EQUIPMENT ATTACHMENT WITH ALL TRADES DRAWINGS.
4. SEE AS404 FOR EQUIPMENT LOCATIONS. GC TO COORDINATE ALL DIMENSIONS
3. SEE AS402 FOR LOCATION AND ELEVATION OF CLEANSUITE.
WITH DIMENSIONS SHOWN.
IMMEDIATELY IF THERE ARE ANY DISCREPANCIES OF CONFLICTS
2. GC SHALL FIELD VERIFY ALL DIMENSION. NOTIFY THE ARCHITECT
WHICH ARE APPLICABLE TO ALL DRAWINGS, UNO.
1. SEE SHEET S001 FOR GENERAL NOTES, SHEET LIST, LEGEND & TYPICAL DETAILS,
SHEET NOTES:
W10X26
(E) BM
W21X132
(E) BM
W
X
(E ) B
M
W16X89
(E) BM
HSS12X12
(E) BRACE
W
X
(E ) B
M
W16X89
(E) BM
H
SS
X1
(E
) B R
AC
E
W
X9
(E ) B
EA
M
HSS12X12
(E) BRACE
W14X211
(E) COL
H
SS
X1
(E
) B R
AC
E
W
X
(E ) B
M
W
X
(E ) B
M
W10X26
(E) BM
W10X26
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W18X86
(E) BM
W18X97
(E) BM
W16X89
(E) BM
W18X97
(E) BM
W16X89
(E) BM
W
X
(E ) B
M
W
X
(E ) B
M
W14X159
(E) COL
W14X211
(E) COL
W14X211
(E) COL
(E )C
X1
5.
V.
I.F
(E )C
X1
5.
V.
I.F
(E) C10X15.3
TO BE V.I.F.
EXISTING OPENING
OPNG.
(E) FLOOR
7'-6"
V.
I.F
2' -1
0"
4/ "
B/STL = +124'-0"
CLEANSUITE FRAMING
W
X
(E ) B
M
W
X
(E ) B
M
(E) C10X15.3
(E) C10X15.3
W
X
(E
) B M
(E ) C
X1
5.
V.
I.F
W21X122
(E) BM
(E ) C
X1
5.
V.
I.F
W
X
(E ) B
M
W14X132
(E) COL
W
X
(E ) B
M
W18X60
(E) BM
W
X
(E ) B
MH
SS
X1
(E
) B R
AC
E
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
MW
X
(E ) B
M
HSS12X12
(E) BRACE
W
X
(E ) B
M W
X
(E
) B M
W
X
(E ) B
M
W10X12
(E) BM
W16X31
(E) BM
W16X31
(E) BM
HSS12X12
(E) BRACE
2' -1
0 "
H
SS
X1
(E
) B R
AC
E
W14X145
(E) COL
W14X145
(E) COL
W14X145
(E) COL
TO BE V.I.F.
EXISTING OPENING
OPNG.
(E) FLOOR
7'-6"
SS302
SS302
SS302
SS302
SS302
NEW ROOF OPENING - ENLARGED PLAN
SCALE = 1:483
Te kl a St ru ct ur es
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
SS105
ROOF FRAMING PLAN
(E) ROOF-PARTIAL PLAN
SCALE = 1:641
B - B
SECTION
SCALE = 1:8C
17 16
B
B
CC
B
1217 16
B
A
15 14 13 1216
A
17 131415
DD
(N
C
X1 5.
W
X
(E ) B
M
(N
C
X1 5.
(N) C10X15.3
HSS8X8X12/
(E) COL ABOVE
W14X132
(E) COL BELOW
(N) C10X15.3
W
X
(E ) B
M
W18X55
(E) BM
W
X
(E ) B
M
W16X31
(E) BM
OVER MTL DECK
IN (E) CONC
SAW CUT OPN'G
W14X145
(E) COL BELOW
W
X
(E
) B M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
W
X
(E ) B
M
SS701
7 8/ "
2' -1
0 "
7'-6"
W14X132
(E) COL BELOW
W
X
(E ) B
M
W14X145
(E) COL BELOW
W14X145
(E) COL BELOW
HSS8X8X12/
(E) COL ABOVE
W
X
(E ) B
M
HSS8X8X12/
(E) COL BELOW
W14X145
(E) COL BELOW
HSS8X8X12/
(E) COL ABOVE
W
X
(E ) B
M
(N) DUCT SEE MECH DWGS
SS701
W
X
(E ) B
M
W
X
(E ) B
M
W16X31
(E) BM
W
X
(E ) B
M
W16X31
(E) BM
W
X
(E ) B
M
W21X122
(E) BM
14'-858/ "
SEE ARCH DWGS
(N) DUCT DOGHOUSE
SEE 3/SS701 FOR CURB DETAIL.
LOCATION AND DIMENSIONS.
CURB. SEE ARCH. FOR
(N) 12" WIDE X 8" HIGH RC
26'-0"
SEE MECH. FOR SUPPORT & BRACING LOCATIONS
SEE DETAIL 10/MH504.
(N) DUCT SUPPORT & BRACING
SEE 3/SS701 FOR CURB DETAIL.
LOCATION AND DIMENSIONS.
CURB. SEE ARCH. FOR
(N) 12" WIDE X 8" HIGH RC
AND DIMENSIONS.
SEE ARCH. FOR LOCATION
(N) 6" THK. CONCRETE PAD.
S E
E A
R C
H D
W G
S
SEE ARCH DWGS
26'-0"26'-0"26'-0"26'-0"
'-0
'-0
9'-338/ "104'-0"
3' -0
'-8 1 2/ "
PL
2"
X3 8"
PL
2"
X3 4"
PL
5 8/
"X
0"
PL38/ "X23 38/ "
PL30"X38"
PL38/ "X23 38/ "
PL
2"
X3 8"
PL
5 8/
"X
0"
PL
5 8/ "X
PL
2"
X3 4"
PL30"X38"
PL
2"
X3 8"
PL
5 8/
"X
0 "
PL
2"
X3 4" a St ru ct ur es
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
SS301
BUILDING SECTIONS
3D VIEW
1:961
ELEVATION W/ (N) AND (E) OPNGS
SCALE = 1:482
BB
A
A
04 FOURTH FLOOR
AB
AB
02 SECOND FLOOR
01 FIRST FLOOR
(E) V.I.F.(E) V.I.F.
(E) V.I.F.
W14X211
(E) COL
W14X145
(E) COL
HS
S1
2X
(E ) B
RA
CE
W14X211
(E) COL
W14X283
(E) COL
W14X132
(E) COLHS
S1 2X
(E
) B
RA
CE
W14X159
(E) COL
W14X159
(E) COL
W14X145
(E) COL
W14X283
(E) COL
HS
S1
2X
(E ) B
RA
CE
(E) V.I.F.
OPENING
HSS12X12
(E) BRACE
2ND FLOOR
HSS12X12
(E) BRACE
HSS12X12
(E) BRACE
HS
S1
2X
(E ) B
RA
CE
HSS8X8X12/
(E) COL
HSS8X8X12/
(E) COL
(E) V.I.F.
OPENING
HSS8X8X12/
(E) COL
(N) OPENING
ROOF FRAMING
4TH FLOOR
3RD FLOOR
1st FLOOR
W14X211
(E) COL
(E) V.I.F.
C10X15.3
HSS12X12
(E) BRACE BEYOND
1178/ "
HSS12X12
(E) BRACE BEYOND
W14X145
(E) COL
(N) C10X15.3
HSS12X12
(E) BRACE BEYOND
HS
S1
2X
(E ) B
RA
CE
B
EY
OND
HSS12X12
(E) BRACE BEYOND
HS
S1
2X
(E ) B
RA
CE
B
EY
OND
1178/ "
Roof FLR=162'-0"
HS
S1
2X
(E ) B
RA
CE
B
EY
OND
HS
S1 2X
(E
) B
RA
CE
B
EY
OND
HSS8X8X12/
(E) COL
W14X145
(E) COL
W14X283
(E) COL
HSS8X8X12/
(E) COL
W14X211
(E) COL
(N) C10X15.3
(E) V.I.F.
C10X15.3
(E) V.I.F.
C10X15.3
W14X283
(E) COL
(E) V.I.F.
OPENING
(N) OPENING
(E) V.I.F.
OPENING
2nd FLR=114'-0"
3rd FLR=130'-0"
4th FLR=146'-0"
1st FLR=98'-0"
(E) C10X15.3
C10X15.3
(E) COL
(E) C10X15.3
6"X18"
(E) COLUMN
2'-10"9'-214/ "
2'-10"
2'-10"
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
Te kl a St ru ct ur es
SS302
CLEANSUITE SECTIONS
ELEVATION
SCALE = 1:241
ELEVATION
SCALE = 1:244
ELEVATION
SCALE = 1:245
ELEVATION
SCALE = 1:243
ELEVATION
SCALE = 1:242
C
C
3rd_130'-0"
TO TRAP ANY POTENTIAL PROBLEMS
A CHANCE TO REVIEW THE FORCES IT EXERTS ON THE STRUCTURE AND ANY DEFLECTIONS THOSE CAUSE THE CLEANSUITE INSTALLATION WILL BE ADEQUATE AT THE TIME IT IS INSTALLED AND WE WILL BE GIVEN
CLEANSUITE BY OTHERS
TYP VERT
TYP DIAGONALTYP DIAGONAL
TYP VERT
FOR BRACING DETAIL
SEE DETAIL 11/SS702
TYP VERT
TYP VERT TYP VERT
TYP DIAGONAL
TYP VERT
CLEANSUITE BY OTHERS
TYP VERT
TYP DIAGONAL
FOR BRACING DETAIL
SEE DETAIL 11/SS702
TYP DIAGONAL
TYP VERT
CLEANSUITE BY OTHERS
TYP VERT TYP VERT TYP VERT
TYP DIAGONAL
FOR BRACING DETAIL
SEE DETAIL 11/SS702
FOR BRACING DETAIL
SEE DETAIL 11/SS702 TYP DIAGONAL
CLEANSUITE BY OTHERS
TYP VERTTYP VERT
TYP DIAGONAL
TYP VERT
CLEANSUITE BY OTHERS
TYP DIAGONAL
TYP VERT
TYP DIAGONAL
FOR BRACING DETAIL
SEE DETAIL 11/SS702
CURB DETAIL AT (N) OPNG
SCALE = 1:85
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
Te kl a St ru ct ur es
SS701
DETAILS
DETAIL TYPICAL @ (N) OPNG
SCALE = 1:168
SCALE = 1:82
SECTION @ (N) OPNG
SCALE = 1:87
ELEVATION W/ (N) HVAC DUCT
SCALE = 1:484
SECTION @ (N) OPNG
SCALE = 1:87
TYPICAL LG WALL TOP
CONN. TO STRUC
SCALE = 1:162
SECTION @ (N) OPNG
SCALE = 1:86
TYPICAL PARTIAL HEIGHT
WALL BRACING DETAIL
SCALE = 1:161
AHU AND CHILLER
ANCHORAGE DETAIL
SCALE = 1:163
B
B
STUD
WALL
(E) METAL DECK w/
CONCRETE FILL
(1)1/2"DIAM KBTZ
X 3 1/4" EMBED.
#8 SMS
SCREW, TYP.
A. CONC FILLED DECK - WALL PARALLEL
+/-45.00°
250T150-54 BRACE @
48" O.C., MAX.
CUT FLANGE AND
BENT 45 DEG., TYP.
(3) #8 SMS SCREW
54 MIL X 1 1
2" FL. CONT TRACK
W/ #8 SMS EA.FL EA. STUD
(1)#10 SMS SCREW
STUD
WALL
(E) METAL DECK w/
CONCRETE FILL
(1)1/2"DIAM KBTZ
X 3 1/4" EMBED.
#8 SMS
SCREW, TYP.
B. CONC FILLED DECK - WALL PERPENDICULAR
+/-45.00°
250T150-54 BRACE @ 48" O.C., MAX.
CUT FLANGE AND BENT 45 DEG., TYP.
(3) #8 SMS SCREW
54 MIL X 1 1
2" FL.
CONT TRACK W/ #8
SMS EA.FL EA. STUD
(1)#10 SMS SCREW
2" MIN.
STUD
WALL
METAL DECK
w/ CONCRETE
FILL
1-1/4"
MIN.
2" x 68 MIL STEEL
STRAP @
EA.STUD, 20" O.C.,
MAX.
(2) #8 SMS PER
STRAP
(1) 0.157" DIA x 1" EMBED
SHOTPIN, ICC ESR 2269 @
EA. STEEL STRAP
54-MIL SLIP STRACK SYSTEMS
REF. ICC ESR -2012
1"
3/4" DEFL. GAP
#8 x 9/16"
WAFERHEAD
FRAMING
SCREW, TYP.
A. CONC FILLED DECK - WALL PARALLEL
STUD WALL
(2) 0.157" DIA x 1"
EMBED SHOTPIN @
EA. FLUTE
B. CONC FILLED DECK - WALL PERP.
METAL DECK w/
CONCRETE FILL
NOTE:
SEE "A" FOR
ADD'L INFO
(E) ROOF SLAB W2 + 3 1/4" LWC
ROUGHEN (E) CONCRETE SURFACE
TO AN AMPLITUDE OF 1/4"
#4 @ 16" O.C. EPOXY DOWEL - HILTI HY200(N) CURB 6" W X 1'-6" H
AROUND NEW OPNG
1#6 CON'T HILTI SHOTPIN XU @ 16" O.C.1#6 CON'T
600T150-43 TRACK 6" STUD
WALL ABOVE - SEE ARCH
EDGE OF (N) OPNG
(N)C10X15.3
3/4" DIAM. @ 4'-0" O.C. MAX. - 2 BOLTS MIN.
(GRADE 5) BOLTS THRU FLOOR ( HOLES ARE
1/16" LARGER THAN BOLT DIAMETER MAX.)
(E) ROOF SLAB W2 + 3 1/4" LWC
STRUT BENEATHE FLOOR
L4X4X3/8 W/ 1/2"DIAM KBTZ
X 3 1/4" EMBED
ISOLATOR
ROUGHEN (E) CONCRETE SURFACE
TO AN AMPLITUDE OF 1/4"
#4 @ 8" O.C. EPOXY DOWEL - HILTI HY200
(N) CURB
#6 @7" E.F.
CON'T.
EQUIPMENT
BASE
AHU - 6A
CH - 6A
ARCH AND MECH VERIFY
TY
P.
MIN
EDGE OF SLAB TYP.
RETURN DUCTS
FOR SUPPLY AND
(N) ROOF OPENING
2' -1
0"
7'-6"
(E) WIDE FLANGE BEAM
BE
AM
S
PA
C
IN
G (1
2' -0
" M
AX
(N) C10X15.3
6"
6"
(N ) C
X
.3
(E) WIDE FLANGE BEAM
(N) C10X15.3
(N )C
X
.3
7 8/ " 6"
6"
M
EC
H V
ER
IF
Y
AR
C H
WALL CONSTRUCTION
DOG HOUSE. SEE ARC FOR STUD
STUD WALL ABOVE TO FORM
6' W X 1'-6" H CURB WITH 6"
1"
OVER METAL DECK
TO SAW-CUTTING (E) CONC
INSTALL (N) FRAME BEFORE
BEAM PER PLAN
(E) BEAM
(N) C10X15.3
(E) SLAB_ON_DECK
(N) PL 38/ " SHEAR_PL
(N) PL 38/ " STIFF_PL
1 4/ 1 4/
3 SIDES TYP
1 4/
3 SIDES TYP
4 15 16/ "
(N) C10X15.3
1"
(E) SLAB_ON_DECK
(N) C10X15.314/ 14/
TYP
OVER METAL DECK
SAWCUT OPN'G IN (E) CONC
1' -1
2/ "
4th =146'-0"
2'-10"
4/ "
W16X31 (E) BM
SEE MECH DWG.
BRACE AS REQUIRED,
W10X26 (E) BEAM (E) C10X15.3
V.I.F.
W16X31 (E) BM
(E) C10X15.3 V.I.F.
(E) C10X15.3 V.I.F.
W16X89 (E) BM
(N) C10X15.3
W16X31 (E) BM
(N) C10X15.3
SEE MECH DWGS
HVAC FOR SPECS
SEE ARCH DWGS
(N) DUCT DOGHOUSE
SEE MECH DWGS
HVAC FOR SPECS
Roof =162'-0"
3rd =130'-0"
2nd FLR=114'-0"
1st FLR=98'-012/ "
6" M
IN
2'-10"
1' -6
5 8/ " 4"
5' -5
3 8/ "
(N) C10X15.3
(N) C10X15.3
14/ 14/
3 SIDES TYP
1"
(N) PL 38/ " STIFF_PL
WALL CONSTRUCTION.
SEE ARC FOR STUD
TO FORM DOG HOUSE.
6" STUD WALL ABOVE
(E) BEAM
( 2 ) 34/ " Ø A325N_TC BOLTS
(E) ROOF SLAB W2 + 3 14/ " LWC
SEE 5/SS701
6' W X 1'-6" H CURB
14/ 14/
3 SIDES TYP
METAL DECK
(E) CONC OVER
SAWCUT OPN'G IN
14/ 14/
TYP
EDGE OF (N) OPNG
6"
(N) C10X15.3
WALL CONSTRUCTION.
SEE ARC FOR STUD
TO FORM DOG HOUSE.
6" STUD WALL ABOVE
METAL DECK
(E) CONC OVER
SAWCUT OPN'G IN
EDGE OF (N) OPNG
SEE 5/SS701
6' W X 1'-6" H CURB
(E) ROOF SLAB W2 + 3 14/ " LWC
6"
(N) C10X15.3
1 4/ 1 4/
TYP1"
GE UPS CABINET ATTACHMENT DETAIL
SCALE = 1:248
Te kl a St ru ct ur es
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
Gene Klow, AIA
(855) 521-1110
Alexandria, Virginia 22314
123 S Royal Street Concourse Federal Group
VAPAHCS Cath Lab Suite Upgrade
3801 Miranda Avenue, Palo Alto, CA
640-13-134
07/10/2020 WT JJA/ KLC
100% - Bid Set www.gplainc.com
Santa Clara, CA 95054 Telephone: 408 654-0475
Structural Engineers and Builders 3350 Scott Blvd, Bldg 48
Gregory P. Luth & Associates, Inc.
Gregory P. Luth, S.E.
Exp. 12/31/2020
S
No. S2718
A
S A
ST UCT
TR
TE OF C
IGE R
E
G
D
RETS
E
FO
YROGER
PR
I
L AA
FORN
IUR
LI
NEE
R
E
I
HT
UL
AL
ON
.P
S
NG
SS702
DETAILS
GE TILTING TABLE ATTACHMENT DETAIL
SCALE = 1:242
GE GANTRY ATTACHMENT DETAIL
SCALE = 1:241
GE AUTO TRANSFORMER ATTACHMENT DETAIL
SCALE = 1:243
GE C1 CABINET ICS730 ATTACHMENT DETAIL
SCALE = 1:244
GE C2 CABINET ICS730 ATTACHMENT DETAIL
SCALE = 1:245
GE CHILLER ATTACHMENT DETAIL
SCALE = 1:246
LARGE CABINET ATTACHMENT DETAIL
SCALE = 1:247
OMNICELL ATTACHMENT DETAIL
SCALE = 1:249
CLEANSUITE SUPPORT AT BEAM DETAIL
SCALE = 1:1610
CLEANSUITE SUPPORT DETAIL
SCALE = 1:1611
DUCT SLEEPER ANCHORAGE DETAIL
SCALE = 1:1610
.7"
20.7"
Y 8"8"
8"
X
FRONT ELEVATION
USE 8-5/8" Ø (A449) THREADED
ROD THRU FLOOR (HOLES TO BE
16" LARGER THAN BOLT
DIAMETER MAX.
POST ASSEMBLY &
BASE PLATE BY
MANUFACTURER
BOLT SPECS: 5
8 " Ø (A449) THREADED ROD
FT = 20,700 LB/BOLT (TENSION)
FV = 11,050 LB/BOLT (SHEAR)
TENSION (T) - Tu_maximum = 10,546 LB/BOLT SHEAR(V) - Vu_maximum = 5,472 LB/BOLT
PLAN AT BASE
NOTE:
1) ANCHORAGE DESIGN PER 2018 CALIFORNIA BUILDING CODE AND
ASCE 7-16 STRENGTH DESIGN IS USED.
Tu Tu Tu
Vu
CG. WT = 2183 LB FOR 165130
= 2204 LB FOR 165140
.9"
13.4"
47.7" (MAX.)
ROTATIVE FIED ARMS
STEEL TUBE POST FOR
TEMPORARY RESTRAINT OF
MOBILE GANTRY BY GE
(8)-5/8" DIAM. A490
THREADED ROD
THRU FLOOR
(E) W2+5.5"LWC
L3X3X1/4
CL
POST/
PLATE
.4"
BOLT FORCES:
1/2" Ø KBTZ X 3 1/4" AT LOWER FLUTE
Y
X
Tu Tu
Vu
.72
27.6"
C.G. WT. = 2,191 LB
(INCLUDES 450 LB PATIENT)
USE 10-M20 (GRADE 5) BOLTS
THRU FLOOR ( HOLES TO BE 1
16"
LARGER THAN BOLT DIAMETER MAX.)
Tu = 3164 LB/BOLT (MAX) Vu = 578 LB/BOLT (MAX)
(E) FLOOR SLAB W2 + 5 1/2" LWC
STRUT BENEATHE FLOOR
L3X3X1/4 W/ 1/2"DIAM KBTZ
X 3 1/4" EMBED
USE 10-M20 (GRADE 5) BOLTS
THRU FLOOR ( HOLES TO BE 1
16"
LARGER THAN BOLT DIAMETER MAX.)
C.G. WT. = 2191 LB
(INCLUDES 450 LB PATIENT)
C.G. WT. = 2191 LB
(INCLUDES 450 LB PATIENT)
(Y = 34.72")
PLAN AT BASE
ELEVATION
NOTE:
1) FORCES ARE DETERMINED PER 2019 CALIFORNIA BUILDING CODE AND ASCE 7-16.
STRENGTH DESIGN IS USED. (SDS = 2.20, ap = 1.0, Ip = 1.5, Ro = 1.5, z/h < 1 HORIZONTAL FORCE (Eh) = 2.64 Wp VERTICAL FORCES (Ev) = 0.44 Wp
2) CENTER OF GRAVITY (C.G.) AND WEIGHT ARE THE GOVERNING PARAMETERS FOR DESIGN. THESE
CALCULATIONS ENCOMPASS ALL WEIGHT UP TO THE MAXIMUM WEIGHT SHOWN.
3) STRUCTURAL ENGINEER OF RECORD FOR THE BUILDING SHALL PROVIDE SUPPORT STRUCTURE DESIGNED TO SUPPORT WEIGHTS AND FORCES SHOWN IN COMBINATION WITH ALL OTHER LOADS THAT MAY BE PRESENT.
LOADS:
PER 2019 CALIFORNIA BUILDING CODE AND ASCE 7-16.
STRENGTH DESIGN IS USED. (SDS = 2.20, ap = 1.0, Ip = 1.5, Ro = 1.5, z/h < 1
WEIGHT = 2,191 LB
HORIZONTAL FORCE (Eh) = 2.64 Wp = 5784 LB VERTICAL FORCES (Ev) = 0.44 Wp = 964 LB
BOLT GROUP PROPERTIES:
Ix-x = 1073 in^4 Iz-z = 950 in^4 Iy-y = 2023 in^4
MOMENTS:
Mxx = 5784# (34.72") = 200,821 " - # Mz-z = 5784# (34.72") = 200,821 " - # My-y = 5784# (0") = 0 " - #
BOLT GROUP PROPERTIES:
FT = 32,873 LB/BOLT (TENSION)
FV = 15,194 LB/BOLT (SHEAR)
4.92" 8.86" 13.78"
7.8 5"
7.8 5"
2.9 7"
2.9 7"
FRONT ELEVATION
USE 2-3/8" Ø (A36) THREADED ROD
THRU FLOOR (HOLES TO BE 1
16"
LARGER THAN BOLT DIAMETER MAX.
Tu Tu
Vu
C.G. WT = 100 LB
(E) FLOOR SLAB W2 + 5 1/2" LWC
STRUT BENEATH FLOOR
L3X3X1/4 WITH 1/2"DIAM. KBTZ
X 3 1/4" EMBED
Vu
SIDE ELEVATION
Tu
Vu
6.4"
C.G.
6.3"
3.2" 11.4"
FRONT ELEVATION
USE 2-3/8" Ø (A449) THREADED
ROD THRU FLOOR (HOLES TO
BE 1
16" LARGER THAN BOLT
DIAMETER MAX.
Tu Tu
Vu
(E) FLOOR SLAB W2 + 5 1/2" LWC
STRUT BENEATH FLOOR
L3X3X1/4 W/ 1/2" DIAM. KBTZ X
3 1/4" EMBED
Vu
SIDE ELEVATION
Tu
Vu
C.G.
Vu
30.76"
Vu
1" MAX.
C.G. WT. =
1010 LB
29.9"
.2"
.8"
TYP. TYPE 3 BACKING PLATE
(16 GA., 50 KSI MIN.) AND
THE WALL STRUCTURE
PRE-MANUFACTURED WALL
BRACKET (BY G.E.) W/ 8 - #12
S.M. SCREWS
TO BACKING PLATE
Tu
12.3" MAX.
EQ
EQ
4" M
AX
8" THK. GYP BOARD
21.4"
FRONT ELEVATION
USE 2-3/8" Ø (A449) THREADED
ROD THRU FLOOR (HOLES TO
BE 1
16" LARGER THAN BOLT
DIAMETER MAX.
Tu Tu
Vu
(E) FLOOR SLAB W2 + 5 1/2" LWC
STRUT BENEATH FLOOR
L3X3X1/4 WITH 1/2" DIAM X
3 1/4" EMBED
Vu
SIDE ELEVATION
Tu
Vu
C.G.
Vu
31.76"
Vu
1" MAX.
C.G. WT. = 567 LB
29.9"
.7"
.3"
TYPE 3 BACKING PLATE
(16 GA., 50 KSI MIN.) AND
THE WALL STRUCTURE
PRE-MANUFACTURED WALL
BRACKET (BY G.E.) W/ 6 - #12 S.M.
SCREWS
TO BACKING PLATE
Tu
11.8" MAX.
EQ
EQ
4" M
AX
8" THK. GYP BOARD
21.4"
FRONT ELEVATION
USE 4 - 1/2" Ø (A36) THREADED
ROD THRU FLOOR (HOLES TO
BE 1
16" LARGER THAN BOLT
DIAMETER MAX.
Tu
Vu
C.G. WT = 325 LB
(E) FLOOR SLAB W2 + 5 1/2" LWC
STRUT BENEATH FLOOR
L3X3X1/4 WITH 1/2" DIAM. KBTZ
X 3 1/4" EMBEDMENT
Vu
PLAN AT BASE
.9"
Tu
(2) - 10 GA. STEEL MOUNTING
BRACKETS W/ (4) 1
4" Ø TEK
SCREWS EACH BRACKET
( BY G.E.)
11" 12.3"
C.G.
8"
11" 12.3"
FRONT ELEVATION
USE 2-3/8" Ø (A449) THREADED
ROD THRU FLOOR (HOLES TO
BE 1
16" LARGER THAN BOLT
DIAMETER MAX.
Tu
Vu
(E) FLOOR SLAB W2 + 5 1/2"LWC
STRUT BENEATH FLOOR
L 3X3X1/4 W/ 1/2" DIAM. KBTZ
X 3 1/4" EMBED.
SIDE ELEVATION
Tu
Vu
C.G.
Vu
C.G. WT. = 254 LBS
TYPICAL BACKING PLATE TYPE 3
(16 GA., 50 KSI MIN.) AND
THE WALL STRUCTURE
PRE-MANUFACTURED WALL
BRACKET (BY G.E.) W/ 4- 1
4" Ø
TEK. SCREWS
TO BACKING PLATE
Tu
8" THK. WALL BOARD
Tu
Vu
Vu
.5"
.6"
.1"
19.3"
19.3"
31.3"
14.5" MAX.
FRONT ELEVATION
USE 4 - M12(CLASS 5.8)
THREADED ROD THRU
FLOOR (HOLES TO BE 1
16"
LARGER THAN BOLT
DIAMETER MAX.
Tu
Vu
C.G. WT = 90 LB MAX.
(E) FLOOR SLAB W2 + 5.5" LWC
STRUT BENEATH FLOOR
L3X3X1/4
PLAN AT BASE
Tu
EATON SEISMIC KIT
(PART NO. SMKITA)
4 BRACKETS
2 STRAPS W/ CINCH
9"
Vu
Tu = 79 LB/BOLT (MAX) Vu = 81 LB/BOLT (MAX)
13.47" +/-
.27
EQ
EQ
C.G. WT = 90 LB MAX.
(Y = 9")
EQ EQ
1/2" DIAM X 3 1/2"
KBTZ AT EA. END
C.G.
2'-33 4" 1'-10 1
2"
2"
3'- 3"
1'-0" 101 2"1'-17
8" 1'-17 8"
3" 91 2"
81 2" 23 8"
1'-
1 2"
51 2"
Fp
2"41 4"13
4"
Fp
MOUNT BRACE BRACKET - PLAN VIEW
WALL
FRONT ELEVATION SIDE ELEVATION
Wp = 1,232 LBS
C.G.
EXISTING SLAB
W2+5 1/2" LWC
MOUNT BRACE BRACKET
LLH 8X4X7/16 + PIN UNIT AT
FRONT WITH END PLATE. -
PROVIDED BY OMNICELL
L3X3X1/4 X 1'-6" MIN.
CLEARANCE TO
WALL, MIN.
(6) 5/8" DIAM. A307 THRU BOLTS AT BASE
BRACKET, TYP. MAX. DRILLED HOLE SIZE =
BOLT DIAM + 1/16".
MOUNT BRACE BRACKET
(6) 5/8" DIAM. A307 THRU BOLTS
L3X3X1/4
CLEARANCE TO
WALL, MIN.
MANUFACTURER PROVIDED PERMANENT PLAQUE
MUST BE AFFIXED ON THE UNIT STATING THE
FOLLOWING "WEIGHT OF CONTENTS SHALL NOT
EXCEED 10 PCF". DESIGNED WEIGHT OF CONTENT
IS 10 PCF. VERIFY IN FIELD BEFORE INSTALLATION.
5/8" DIAM. A307 THRU BOLTS AT BASE BRACKET
ANCHOR HOLES, 6 TOTAL PER BRACKET.
1/2" END PLATE WITH PIN UNIT -
PROVIDED BY MANUFACTURER NOTES:
1. VERIFY THAT THE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .