S02 518-18-035_Construction Drawings Final R1 02042020 with deduct alternates-part 1 of 4.pdf

PDF 8 MB Posted

Attached to
Z2DA--Renovate Correct Outpatient Mental Health Clinic Project 518-18-035
Solicitation number
36C24120R0144
Issued by

About this file

This document is a request for proposals for renovating an outpatient mental health clinic. The solicitation involves projects 518-18-001 and 518-18-035 to correct mental health deficiencies at a Veterans Affairs medical center in Bedford, Massachusetts. Contractors must furnish all labor, materials, equipment, transportation, and supervision to complete construction according to drawings, specifications, and applicable attachments. The technical representative is Michael Sanford and administrative contracting officer is Richard Coutermarsh. The estimated value is between $10-20 million. This solicitation is 100% set aside for service-disabled veteran-owned small businesses. To be eligible for award, offerors must be verified as SDVOSBs by the Center for Veteran Enterprise and VetBiz at time of proposal submission and award. A site visit is scheduled for July 29, 2020, with proposals due by September 4, 2020.

View the file

Other files

File Type Posted
Amendment 0009 Answers to Vendor Questions.pdf PDF
36C24120R0144 0009.pdf PDF
224000 - PLUMBING FIXTURES - 20200902 Revision 1.pdf PDF
Amendment 0008 Answer to Vendor Questions.pdf PDF
VAMC Bedford Building 6_RFI 09_WME Reponse.pdf PDF
36C24120R0144 0008.pdf PDF
VAMC Bedford Building 6_RFI 07_WME Reponse.pdf PDF
102123_Cubicle Curtain.pdf PDF
2020-08-13 VAMC Bedford 6B Renovation Pre-Bid RFI 01.pdf PDF
2020-08-18_VAMC Bedford_leopardo rfi questions_WME Response.xlsx XLSX spreadsheet
2020.08.20_AE103 and AE602_REV2 Window Fire-Ratings.pdf PDF
Amendment 0007 Answer to Vendor Questions.pdf PDF
B6 Elevation_(11304).PDF PDF
22 40 00 Plumbing Fixtures_REV1.pdf PDF
B6 Elevation_(11305).PDF PDF
36C24120R0144 0007.pdf PDF
leopardo rfi questions_combined 08202020.xlsx XLSX spreadsheet
518-15-103 Upgrade Water - Geotechnical Report and drawings 10-18-2018.pdf PDF
Section 10 25 13 Patient Bed Service Walls from Final Specifications REV1 02182020.pdf PDF
MCE ACM_LBP Bedford VAMC Rpt-(1).pdf PDF
15767 Boring (1979).pdf PDF
2020.08.20_08 80 00 Glazing_REV1.pdf PDF
2020.08.25_VAMC Bedford Building 6_RFI 05_WME Reponse.pdf PDF
062013_GRFC.pdf PDF
leopardo rfi questions and answers.pdf PDF
2020-08-13 VAMC Bedford 6B Renovation Pre-Bid RFI 01-1.pdf PDF
B6 Elevation (11304).PDF PDF
B6 Elevation (11305).PDF PDF
MCE ACM_LBP Bedford VAMC Rpt.pdf PDF
36C24120R0144 0006.pdf PDF
Section 10 25 13 Patient Bed Service Walls from Final Specifications_REV1 02182020.pdf PDF
2020-08-13_VAMC Bedford 6B Renovation_Pre-Bid RFI 01.pdf PDF
2020-08-13_Transmittal 12_Correct Mental Health Deficiencies 6B - VAMC Bedford_Pre-Bid RFI 02.pdf PDF
VAMC Bedford Building 6_RFI 02_WME Reponse.pdf PDF
Answers to Vendor Questions.pdf PDF
36C24120R0144 0005.pdf PDF
2020-08-13_Transmittal 11_Correct Mental Health Deficiencies 6B - VAMC Bedford_Pre-Bid RFI 01.pdf PDF
14 24 00 Hydraulic Elevators_REV01.pdf PDF
2020-08-13_VAMC Bedford 6B Renovation_Pre-Bid RFI 01-1.pdf PDF
room B12 part 3.pdf PDF
room B12 part 1.pdf PDF
Questions and Answers.pdf PDF
room B12 part 2.pdf PDF
site walkthrough 581-18-001 518-18-035 07292020.pdf PDF
36C24120R0144 0004.pdf PDF
S06 36C24120R0144 0003.docx DOCX document
S06 36C24120R0144 0002.docx DOCX document
S06 36C24120R0144 0001.docx DOCX document
S02 518-18-001 Final Specifications_REV1 02182020.pdf PDF
S02 Wage Rates MA20200001 03132020.pdf PDF
Show 40 more

Latest 50 of 60 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION: BUILDING #6

GENERAL INFORMATION:

LOCATION: RESPONDING FIRE

DEPARTMENT:

AUTHORITIES HAVING

JURISDICTION:

BEDFORD VAMC MENTAL HEALTH

BUILDING 6

BEDFORD, MA

BEDFORD, MASSACHUSETTS FIRE

DEPARTMENT

DEPARTMENT OF VETERANS

AFFAIRS

PROJECT DESCRIPTION:

RENOVATION OF FIRST FLOOR FOR OUT-PATIENT MENTAL HEALTH SERVICES; NEW FINISH WORK IN LOWER LEVEL; LIMITED EXTERIOR REPAIR

INCLUDING ADDITION OF NEW ENTRY COVER ON WEST FACADE

APPLICABLE CODES

OCCUPANCY (Section 303) & STRUCTURAL CLASSIFICATION

Lower Level: Business - occupancy unchanged Main Level: Business - Out-patient Mental Health Clinic Second Level: Healthcare - occupancy unchanged - In-patient Mental Health Care

BUILDING HEIGHT AND AREA:

Total Area per Floor:

Total Building Area:

13,543 sq. ft.

40,629 sq. ft.

3 Stories - 43'

All current codes, guidelines and standards according to the following:

VA Architectural Design Manual (2014) VA Mental Health Facilities Design Manual (2017) VA Fire Protection Design Manual (2015) PG 18-14 Room Finishes, Door, and Hardware Schedule (2017) PG-18-13 Barrier Free Design Standard PG-18-12 Mental Health Outpatient Services Design Guide VA Handbook H-18-8 Seismic Design Requirements Physical Security Design Manual International Building Code (2018)

Construction Type:

IBC - Type II-A NFPA - Type II (111) Seismic Category: C

NFPA Codes, Handbooks, Standards, etc. Including, but not limited to - NFPA 13 – Automatic Sprinkler Systems Handbook NFPA 20 – Stationary Fire Pumps NFPA 70 – National Electrical Code NFPA 70E – Standard for Electrical Safety in the Workplace NFPA 72 – National Fire Alarm and Signaling Code NFPA 75 – Standard for the Fire Protection of Information Technology Equipment NFPA 80 – Standard for Fire Doors and Opening Protectives NFPA 99 – Health Care Facilities NFPA 101 – Life Safety Code NFPA 110 – Standard for Emergency and Standby Power Systems NFPA 780 – Installation of Lightening Protection Systems

PROJECT LOCATION

MIDDLESEX

COMMUNITY

COLLEGE

EDITH NOURSE

ROGERS

MEMORIAL

HARTWELL

TOWN FOREST

BEDFORD

ELM BROOK

CONSERVATION

AREA

HANSCOM AFB

PINE MEADOWS

COUNTRY CLUB

H MART BURLINGTON

BURLINGTON MALL

BURLINGTON

LANDLOCKED

FOREST

VINE BROOK

WELLFIELD

INTERSTATE

Department of Veterans Affairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

Approved: Project Director

TJW NPL

100%

S U

B M

IT

TA

L

SEAL:ARCHITECT/ENGINEER:

35% DESIGN SUBMISSION 11/21/2018

DRAWING INDEX

BUILDING SIX

60% DESIGN SUBMISSION 1/25/2019

90% DESIGN SUBMISSION 8/30/2019

90% DESIGN RESUBMISSION 10/23/2019

100% DESIGN SUBMISSION 12/11/2019

STRUCTURAL ENGINEER

BOB D. CAMPBELL

4338 BELLEVIEW AVENUE

KANSAS CITY, MO 64111

(816) 531-4144

MEP ENGINEER

WATSON ENGINEERING

1112 STATE ROUTE 434

OWEGO, NY 13827

(607) 223-4334

FIRE PROTECTION ENGINEER

CMG FIRE PROTECTION

10727 W/ 128 STREET

OVERLAND PARK, KS 66213

(913) 239-8900

100% R1 DESIGN SUBMISSION 1/24/2020

G101

TITLE SHEET

BEDFORD VAMC MENTAL HEALTH

518-18-035

BEDFORD, MA

BEDFORD VAMC

MENTAL HEALTH

BEDFORD, MA

518-18-035

2020.01.24

LOCATION MAP

INFORMATION

G101 TITLE SHEET

G201 INFORMATION

G301 CODE REVIEW - LOWER LEVEL

G302 CODE REVIEW - MAIN LEVEL

G401 PHASING PLANS

NORTH

ARCHITECTURAL

D101 DEMOLITION PLAN - LOWER LEVEL

D102 DEMOLITION PLAN - MAIN LEVEL

D103 DEMOLITION PLAN - ROOF

A001 ARCHITECTURAL SITE PLAN

A002 SITE DETAILS

A101 ARCHITECTURAL FLOOR PLAN - LOWER LEVEL

A102 ARCHITECTURAL FLOOR PLAN - MAIN LEVEL

A110 ENLARGED FLOOR PLANS - LOWER LEVEL

RESTROOMS

A111 ENLARGED FLOOR PLANS - MAIN LEVEL

RESTROOMS

A201 EXTERIOR ELEVATIONS

A202 EXTERIOR ELEVATIONS

A203 EXTERIOR ELEVATIONS

A204 EXTERIOR ELEVATION DETAILS

A301 BUILDING SECTIONS

A302 WALL SECTIONS

A310 DETAILS

A311 INTERIOR COLUMN DETAILS

A320 STAIR DETAILS

A321 STAIR DETAILS

A401 ARCHITECTURAL ROOF PLAN

A402 ROOF DETAILS

A501 DOOR, FRAME, & WINDOW SCHEDULES

A502 DOOR, FRAME, & WINDOW DETAILS

A601 REFLECTED CEILING PLAN - LOWER LEVEL

A602 REFLECTED CEILING PLAN - MAIN LEVEL

A701 FINISH FLOOR PLAN - LOWER LEVEL

A702 FINISH FLOOR PLAN - MAIN LEVEL

A703 FINISH SCHEDULE

FE101 FIXED EQUIPMENT PLAN - LOWER LEVEL

FE102 FIXED EQUIPMENT PLAN - MAIN LEVEL

FE201 FIXED EQUIPMENT PLAN - ENLARGED FLOOR PLANS

FE202 FIXED EQUIPMENT ELEVATIONS

FE203 FIXED EQUIPMENT ELEVATIONS

FE301 SIGNAGE SCHEDULE & DETAILS

FE302 EQUIPMENT SCHEDULES

PLUMBING

P001 PLUMBING ABBREVIATIONS & SYMBOLS

PD101 EXISTING & DEMO LOWER LEVEL PLUMBING PLAN

PD102 EXISTING & DEMO MAIN LEVEL PLUMBING PLAN

MECHANICAL

M001 MECHANICAL ABBREVIATIONS & SYMBOLS

MD101 EXISTING & DEMO LOWER LEVEL HVAC PLAN

MD102 EXISTING & DEMO MAIN LEVEL HVAC PLAN

E101 PROPOSED LOWER LEVEL ELECTRICAL PLAN

E102 PROPOSED FIRST FLOOR ELECTRICAL PLAN

E103 PROPOSED LOWER LEVEL LIGHTING PLAN

E104 PROPOSED MAIN LEVEL LIGHTING PLAN

E105 PROPOSED LOWER LEVEL LOW VOLTAGE

ELECTRICAL PLAN

E106 PROPOSED MAIN LEVEL LOW VOLTAGE ELECTRICAL

PLAN

E501 ELECTRICAL DETAILS

E601 EXISTING & DEMO ELECTRICAL ONE-LINE DIAGRAM

E602 PROPOSED ELECTRICAL ONE-LINE DIAGRAM

E603 ELECTRICAL SCHEDULES

E604 PANEL SCHEDULES

E605 ELECTRICAL RISER DIAGRAM

M101 PROPOSED LOWER LEVEL HVAC PLAN

M102 PROPOSED MAIN LEVEL HVAC PLAN

MP101 PROPOSED LOWER LEVEL HVAC PIPING PLAN

MP102 PROPOSED MAIN LEVEL HVAC PIPING PLAN

M401 TYPICAL AHU SECTION VIEW

M501 MECHANICAL DETAILS

M502 MECHANICAL DETAILS

M503 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

M602 MECHANICAL SCHEDULES

M603 MECHANICAL SCHEDULES

M604 MECHANICAL SCHEDULES

M605 PSYCHROMETRIC CHARTS

M606 AHU CONTROLS SCHEMATIC & POINTS LIST

M607 HVAC CONTROLS SCHEMATIC & POINTS LIST

MEP INFORMATION

MEP100 MEP CODE ANALYSIS & GENERAL NOTES

ELECTRICAL

E001 ELECTRICAL ABBREVIATIONS & SYMBOLS

ED101 EXISTING & DEMO LOWER LEVEL ELECTRICAL PLAN

ED102 EXISTING & DEMO MAIN LEVEL ELECTRICAL PLAN

P101 PROPOSED LOWER LEVEL PLUMBING PLAN

P102 PROPOSED MAIN LEVEL PLUMBING PLAN

P501 PLUMBING DETAILS

P601 PLUMBING RISER DIAGRAMS

PROJECT INFORMATION

VICINITY MAP

NORTH

STRUCTURAL

S001 GENERAL NOTES

S100 CANOPY PLANS AND SECTIONS

S101 STAIR FRAMING PLAN AND SECTIONS

FIRE PROTECTION

FA101 FIRE ALARM FLOOR PLAN - LOWER LEVEL

FA102 FIRE ALARM FLOOR PLAN - MAIN LEVEL

FA202 FIRE ALARM DETAILS

FX100 FIRE SPRINKLER FLOOR PLAN - LOWER LEVEL

EXISTING

FX101 FIRE SPRINKLER FLOOR PLAN - LOWER LEVEL NEW

WORK

FX102 FIRE SPINKLER EXISTING PLAN - MAIN LEVEL

FX103 FIRE SPINKLER FLOOR PLAN - MAIN LEVEL

VHABEDSanfoM Text Box

DEDUCT ALTERNATES

DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.

DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

NOTE: REFER TO SPECIFICATIONS FOR

ADDITIONAL ABBREVIATIONS OF REFERENCED

STANDARDS, REGULATORY AGENCIES,

ASSOCIATIONS AND OTHERS

A.B ANCHOR BOLT

ABV ABOVE

AD ACTUAL DIMENSION, ACCESS

DOOR

ADJ ADJACENT

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANCH ANCHOR

ANGLE

ARCH ARCHITECTURAL

@ AT

AVG R AVERAGE "R" FACTOR FOR

INSULATION

B/C BACK OF CURB

BD BOARD

BLDG BUILDING

BM BEAM

BM BENCH MARK

BRG BEARING

BTM BOTTOM

BUR BUILT-UP ROOFING

CABT CABINET

CB CATCH BASIN

CH COAT HOOK

CI CAST IRON

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CENTER LINE

CLG CEILING

CMU CONCRETE MASONRY UNIT

CMT CERAMIC MOSAIC TILE

CMP CORRUGATED METAL PIPE

CO CLEAN OUT

COL COLUMN

CONC CONCRETE

COND CONDITION

CONST CONSTRUCTION

CONT CONTINUOUS, CONTINUE

CR1 COMMUNICATIONS RISER

CTSK COUNTERSUNK

CUH CABINET UNIT HEATER

DBL DOUBLE

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DR DOOR

DWG DRAWING

DWG(S) DRAWING (S)

DS(0) DOWNSPOUT (OUTLET)

DTL DETAIL

E EAST

EA EACH

EC ELECTRICAL CONTRACTOR

EF EACH FACE

EJ EXPANSION JOINT

ELEC ELECTRICAL

EL, ELEV ELEVATION

ENCL ENCLOSURE

EQ EQUAL

EQUIP EQUIPMENT

E.W. EACH WAY

EXP EXPANSION

EXT EXTERIOR, EXTERNAL

EXIST,EX EXISTING

FA FRESH AIR

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FFCO FLUSH FLOOR CLEANOUT

FH FLAT HEAD

FHC FIRE HOSE CABINET

FIN FINISH

F FLOWLINE

FL,FLR FLOOR

FLRG FLOORING

FND FOUNDATION

FOS FACE OF STRUCTURE

FR FIRE RATED, FIRE RESISTIVE

FS FLOOR SINK, FOOD SERVICE

FT FEET OF FOOT

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERAL

GFRC GLASS FIBER REINFORCED

CONCRETE

GI GALVANIZED IRON

GL GLASS

GYP GYPSUM

HB HOSE BIBB

HC HANDICAPPED (ACCESSIBLE)

HD HAND DRYER

HDWE HARDWARE

HD WD HARD WOOD

HM HOLLOW METAL

HT HEIGHT

HORIZ HORIZONTAL, HORIZONTALLY

HPL HIGH PRESSURE LAMINATE

HR HOUR

HVAC HEATING VENTILATING & AIR

CONDITIONING

ID INSIDE DIAMETER

INSUL INSULATION

INT INTERIOR

INTERM INTERMEDIATE

JB JUNCTION BOX

JT(S) JOINT(S)

LB LOCKER BENCH

LCS LIQUID CAULK SURFACE

LLV LONG LEG VERTICAL

LT WT LIGHTWEIGHT

LT LIGHT

LWCMU LIGHTWEIGHT CONCRETE

MASONRY UNIT

MAS MASONRY

MAT, MATL MATERIAL

MAX MAXIMUM

MB MACHINE

MC MECHANICAL CONTRACTOR

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL, MECHANISM

MFGR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MS MACHINE SCREW

MTL METAL

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO,# NUMBER

NOM NOMINAL

NTS NOT TO SCALE

NWCMU NORMAL WEIGHT CONCRETE

MASONRY UNIT

OA OVERALL

OC(S) ON CENTER

(STAGGERED, IF 2 ROWS)

OD OVERFLOW DRAIN

OFF OFFICE

OPER OPERATOR, OPERABLE, OPERATING

OPNG OPENING

OTO OUT-TO OUT

OZ OUNCE

PARTN PARTITION

PBD PARTICLE BOARD

PC PORTLAND CEMENT, PIECE

PERIM PERIMETER

PL PLATE

PLAM PLASTIC LAMINATE

PNL PANEL

PWD PLYWOOD

PR PAIR

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PVMT PAVEMENT

QTY QUANTITY

QT QUARRY TILE

R&R REMOVE & REPLACE

R RADIUS

RA RETURN AIR

RCP REINFORCED CONCRETE PIPE

RD ROOF DRAIN

REF REFER TO, REFERENCE

REFL REFLECTED

REINF REINFORCING, REINFORCED

REQ'D REQUIRED

REV REVERSED

RJ RUSTICATION JOINT

RMS ROOMS

RO ROUGH OPENING

RTU ROOF TOP UNIT

S SOUTH

SAN SANITARY

SC SAWCUT

SD SOAP DISPENSER

SECT SANITARY

SF SQUARE FOOT

SFCMU SPLIT FACE CONCRETE MASONRY

UNIT

SHT SHEET

SIM SIMILAR

SLV SHORT LEG VERTICAL

SMS SHEET METAL SCREWS

SND SANITARY NAPKIN DISPENSER

SNR SANITARY NAPKIN RECEPTACLE

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENSION

SYM SYMMETRICAL

TB TACKBOARD

TD TOWEL DISPENSER & DISPOSER

(PAPER); OR TRENCH DRAIN

T & G TONGUE AND GROOVE

TEMP TEMPERED, TEMPORARY

TEXT TEXTURED

THK THICK

TLT TOILET

TOC TOP OF CURB OR CONCRETE

TOS TOP OF SLAB, STEEL OR

STRUCTURE

TP TOILET PAPER DISPENSER

TPL TWO PERSON LOCKER

TWS TACTILE WARNING SURFACE

TXFR TRANSFORMER

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

US URINAL SCREEN

V.C.P. VITEOUS CLAY PIPE

V.C.T. VINYL COMPOSITION TILE

VERT. VERTICAL, VERTICALLY

V.W.C. VINYL WALL COVERING

W WEST

W/ WITH

WC WATER CLOSET

WD WOOD

WDW WINDOW

W/O WITH OUT

WO WHERE OCCURS

WT WEIGHT

WWF WELDED WIRE FABRIC

WPG WATERPROOFING

SECTION MARK- 1 = DETAIL NUMBER

A1.1 = SHEET NUMBER

INTERIOR ELEVATION MARKER:

A2.2 = SHEET NUMBER

6 = DETAIL NUMBER

BUILDING ELEVATION MARKER:

A2.1 = SHEET NUMBER

6 = DETAIL NUMBER

Note: REF. SITE PLAN LEGEND, ROOF PLAN LEGEND AND CEILING PLAN

LEGEND FOR ADDITIONAL NOTES AND LEGENDS.

BUILDING SECTION

ALUMINUM FRAME MARK -

REFERENCE FRAME ELEVATIONS

COLUMN GRID NUMBERS AND/OR LETTERS

D.F.(2)D.F

LEVEL 1

0'-0"

A1.1

SIM

A1.1

SIM

WALL SECTION

A2.1 6

EXISTING DOOR - UNMODIFIED

EXISTING DOOR - MODIFIED

NEW DOOR

EXPANSION JOINT

CONTROL JOINT

SAWCUT CONCRETE FLOOR JOINTS- REFERENCE

STRUCTURAL DRAWINGS FOR EXACT LOCATIONS

NEW FINISH SPOT ELEVATIONS IN FEET AND INCHES

(OR ON SITE PLAN IN FEET AND DECIMALS)

EXISTING SPOT ELEVATION

DOOR MARK - REFERENCE DOOR AND

FRAME SCHEDULE

LOCATION OF SYMBOL ON PAIR OF

DOORS INDICATES THE ACTIVE LEAF

LOCKERS: X INDICATES FILLER UNITS

PARTITION MARK - REFERENCE PARTITION

SCHEDULE

( ) INDICATES FIRE RATING OF WALL IN HOURS

PLAN NOTES

DETAIL MARKS: 1 = DETAIL NUMBER

A1.1 = SHEET NUMBER

SIM = SIMILAR

EQUIPMENT OR FURNISHINGS SHOWN ON FLOOR

PLANS. INDICATES FURNISHINGS BY OWNER (N.I.C.)

ON FIXED EQUIPMENT PLANS

ELEVATION MARK IN FEET AND INCHES

CASEWORK DESIGNATION; NUMBER INDICATES UNIT

NUMBER IDENTIFIED IN MANUFACTURED CASEWORK

SCHEDULE. REFERENCE SPECIFICATIONS.

GLASS TYPE - REFERENCE GLASS

SCHEDULE ON SHEET A501

FLOOR DRAIN (ELEVATION IN FEET AND

INCHES WHERE INDICATED)

MOP/JANITOR SINK

WATERCLOSET, URINAL, LAVATORY

(RESPECTIVELY)

DRINKING FOUNTAIN - REFERENCE

PLUMBING

A2.2

A1

C J

E J

S C

100'-0"

100'-0"

M12a(3)

1i

FURNITURE TAG, WHEN FURNITURE IS

INCLUDED IN CONTRACT

FD FD

99'-10"

COLUMN

GYPSUM BOARD GENERAL NOTES

G2a

GYPSUM

GYPSUM BOARD PARTITION:

1 5/8" STEEL STUD FURRING @ 16" OC - COVER ONE SIDE WITH

5/8" TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO 4" ABOVE

CEILING.

REFER TO PARTITION DETAILS BELOW

UNLESS NOTED OTHERWISE, EXTEND GYPSUM BOARD 4"

ABOVE FINISHED CEILING ELEVATION.

UNLESS NOTED OTHERWISE, PROVIDE 3 1/2" ACOUSTICAL

INSULATION IN ALL PARTITIONS.

FRAME AROUND DUCTWORK, BACK BRACE AS REQUIRED

FOR STABILITY.

REFER TO HOLLOW METAL FRAME DETAILS FOR

ADDITIONAL DETAIL REQUIREMENTS.

EXTEND STUDS TO TOP RUNNER ATTACHED TO

STRUCTURE ABOVE, OR BACK BRACE TO STRUCTURE AS

NECESSARY TO FULLY STABILIZE THE PARTITIONS.

REFER TO COLUMN DETAILS FOR ADDITIONAL DETAIL

REQUIREMENTS.

REFER TO FINISH SCHEDULE FOR WALL FINISH.

ALL PENETRATIONS THROUGH GYPSUM BOARD

PARTITIONS EXPOSED TO VIEW WILL BE TRIMMED NEAT

AND TRUE AND SEALED.

GYPSUM BOARD PARTITION:

3 5/8" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH 5/8"

TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO UNDERSIDE

OF DECK AND FILL VOIDS WITH 3 1/2" ACOUSTICAL INSULATION.

PROVIDE FIRE BLOCKING WHEN OVER 12'-0".

G5a

GYPSUM BOARD PARTITION:

3 5/8" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH 5/8"

TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO 4" ABOVE

CEILING. PROVIDE FIRE BLOCKING WHEN OVER 12'-0".

G5b

EXISTING

G3a GYPSUM BOARD PARTITION:

2 1/2" STEEL STUD FURRING @ 16" OC - 1" GAP BETWEEN EXISTING AND

NEW. COVER ONE SIDE WITH 5/8" TYPE "X" GYPSUM BOARDS. FILL WITH

CLOSED CELL SPRAY APPLIED INSUL. - 3" MIN. EXTEND PARTITION TO

UNDERSIDE OF DECK.

1"

EXISTING

GYPSUM BOARD PARTITION:

3 5/8" STEEL STUDS @ 16" OC - COVER ONE SIDE WITH 5/8"

TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO 4" ABOVE

CEILING. PROVIDE FIRE BLOCKING WHEN OVER 12'-0".

G5c

GYPSUM BOARD PARTITION:

6" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH 5/8" TYPE "X"

GYPSUM BOARDS. EXTEND PARTITION TO UNDERSIDE OF DECK

AND FILL VOIDS WITH 5 1/2" ACOUSTICAL INSULATION.

G7a

GYPSUM BOARD PARTITION:

3 5/8" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH (2)

LAYERS 5/8" TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO

UNDERSIDE OF DECK AND FILL VOIDS WITH 3 1/2" ACOUSTICAL

INSULATION. FIRE RATED PARTITION - UL #U419; 2HR RATING

G5d

GYPSUM BOARD PARTITION:

3 5/8" STEEL STUDS @ 16" OC - COVER ONE SIDE WITH 5/8" TYPE

"X" GYPSUM BOARDS. EXTEND PARTITION TO UNDERSIDE OF

DECK. PROVIDE FIRE BLOCKING WHEN OVER 12'-0".

G5e

1. GENERAL CONTRACTOR SHALL NOTIFY THE VA PROJECT ENGINEER/COR

OF ANY DISCREPANCIES BETWEEN SPECIFICATIONS AND DRAWINGS,

BETWEEN MULTIPLE SPECIFICATION SECTIONS AND/OR BETWEEN

MULTIPLE DRAWINGS. THE VA PROJECT ENGINEER WILL DETERMINE

WHICH SHALL GOVERN. THE MOST RESTRICTIVE OR ANTICIPATED BY

CODE WILL BE THE DEFAULT.

2. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND

CONDITIONS OF THE JOB SITE INCLUDING UTILITIES AND EXISTING

STRUCTURES PRIOR TO BEGINNING WORK AND REPORT ANY

DISCREPANCIES TO THE VA PROJECT ENGINEER/COR.

3. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR STABILITY OF THE

STRUCTURE DURING CONSTRUCTION INCLUDING ALL SHORING AND

BRACING REQUIRED TO RESIST REQUIRED VERTICAL AND LATERAL

FORCES. ALL ACTIVITIES INVOLVING THE EXISTING STRUCTURE REQUIRE

SIGN-OFF BY A LICENCED STRUCTURAL ENGINEER.

4. ALL ARCHITECTURAL FLOOR PLAN DIMENSIONS ARE FROM FACE OF

CONCRETE, MASONRY AND STEEL STUD.

5. HORIZONTAL MASONRY DIMENSIONS FROM OUTSIDE TO OUTSIDE

CORNERS ARE ACTUAL. WHEN DIMENSIONS ARE 2'-8" OR LESS,

CONSTRUCT ONE JOINT LESS THAN DIMENSION SHOWN.

6. GYPSUM BOARD PARTITIONS ARE TYPE G5a UNLESS INDICATED

OTHERWISE.

7. GENERAL CONTRACTOR SHALL PROVIDE 3½” HIGH CONCRETE CURBS AT

ALL ELECTRICAL PANELS AND WHERE 2 OR MORE CONDUITS ARE

EXPOSED AT THE FLOOR LINE.

8. MECHANICAL /ELECTRICAL CONTRACTOR SHALL SIZE AND GENERAL

CONTRACTOR SHALL FORM, DOWEL AND POUR INTERIOR AND EXTERIOR

BASES FOR MECHANICAL AND ELECTRICAL EQUIPMENT (3½” AT INTERIOR

LOCATIONS AND 4” AT EXTERIOR LOCATIONS UNLESS INDICATED

OTHERWISE). REFER TO GENERAL PROVISIONS OF MECHANICAL

SPECIFICATIONS FOR MINIMUM SIZES. UNLESS INDICATED OTHERWISE,

REINFORCE WITH 4”x4” – W4.0xW4.0 WWF.

9. NO WALL FINISH OTHER THAN PAINT IS REQUIRED BEHIND CABINETS,

CHALKBOARDS, TACKBOARDS, ETC UNLESS WALL BEHIND IS EXPOSED

TO VIEW AND/OR WHERE NOTED OTHERWISE.

10. PROVIDE WALL BASE AT ALL CABINETS, SHELVING AND COLUMNS; AND

AS SCHEDULED.

11. PROVIDE LINTELS (REF. STRUCTURAL AND MISC. LINTEL SCHEDULE) FOR

ALL OPENINGS IN MASONRY WALLS FOR FIRE EXTINGUISHER CABINETS,

LOUVERS, GRILLES, DOORS, ETC.

12. GROUT SMOOTH ALL CONCRETE COLUMNS AND WALLS PRIOR TO

PAINTING. GROUT CONCRETE TO BE PAINTED WITH DRYWALL COMPOUND.

CONCRETE COLUMNS AND WALLS SCHEDULED NOT TO BE PAINTED,

GROUT WITH CEMENTITIOUS MATERIAL TO MATCH CONCRETE.

13. CONTINUE CONTROL JOINTS, INCLUDING SEALANTS, ABOVE CEILING

ELEVATIONS FOR FULL HEIGHT OF WALL OR PARTITION.

14. CONSTRUCT ALL MASONRY PARTITIONS THAT EXTEND TO THE

UNDERSIDE OF STRUCTURE WITH A ¾” CLEARANCE AROUND ALL

STRUCTURE AND FILL VOIDS WITH SAFING INSULATION, UNLESS NOTED

OTHERWISE.

15. PROVIDE 6" STEEL BLOCKING IN GYPSUM BOARD PARTITIONS BEHIND

CASEWORK. BLOCK AT TOP OF BASE UNITS, TOP & BOTTOM OF WALL

UNITS, TOP AND MID-HEIGHT OF TALL UNITS. PROVIDE 6" STEEL

BLOCKING IN GYPSUM BOARD PARTITIONS BEHIND GRAB BARS, DOOR

STOPS, WALL- MOUNTED SHELVING, WALL-MOUNTED TV’S AND OTHER

LOCATIONS AS SPECIFIED OR NOTED. CUT TO FIT SNUGLY BETWEEN

STUDS & KERF AT STUD FLANGES TO FIT FIRMLY TO BACK OF DRYWALL.

16. REFER TO STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR

REINFORCING STEEL IN MASONRY WALLS AND POURED CONCRETE.

17. REFER TO CODE COMPLIANCE PLANS FOR FIRE RATINGS OF PARTITIONS

AND SMOKE BARRIER LOCATIONS. GENERAL CONTRACTOR SHALL BE

RESPONSIBLE FOR CONSTRUCTION OF PARTITIONS AND BARRIERS TO

COMPLY WITH RATINGS INDICATED.

18. CONTRACTOR TO FIRESTOP ALL EXISTING AND NEW PENETRATIONS IN

ALL FIRE RATED WALLS AND FLOORS.

CEILING LINE WHERE

APPLICABLE

5/8" TYPE "X" GYP.

BD. EA. SIDE

3 5/8" STEEL STUD

FRM'G @ 16" o.c.

3 1/2" ACOUSTICAL

INSULATION

SEALANT

FINISH FLOOR

BOT. OF

STRUCTURE

IN WET LOCATIONS,

SUBSTITUTE

CEMENTITIOUS

BACKERBOARD FOR

GYP. BD.

CEILING LINE WHERE

APPLICABLE

5/8" TYPE "X" GYP.

BD. ONE SIDE

1 5/8" STEEL STUD

FRM'G @ 16" o.c.

1 1/2" ACOUSTICAL

INSULATION

SEALANT

FINISH FLOOR

BOT. OF

STRUCTURE

G5aG2a

CEILING LINE WHERE

APPLICABLE

5/8" TYPE "X" GYP.

BD. ONE SIDE

2 1/2"" STEEL STUD

FRM'G @ 16" o.c.

CLOSED CELL

SPRAY APPLIED

INSULATION - 3" MIN.

SEALANT

FINISH FLOOR

BOT. OF

STRUCTURE

G3a

SEALANT

1"

SEALANT

EXISTING EXTERIOR

WALL

CEILING LINE WHERE

APPLICABLE

5/8" TYPE "X" GYP.

BD. ONE SIDE

3 5/8" STEEL STUD

FRM'G @ 16" o.c.

3 1/2" ACOUSTICAL

INSULATION

SEALANT

FINISH FLOOR

BOT. OF

STRUCTURE

G5c

CEILING LINE WHERE

APPLICABLE

5/8" TYPE "X" GYP.

BD. EA. SIDE

6" STEEL STUD

FRM'G @ 16" o.c.

5 1/2" ACOUSTICAL

INSULATION

SEALANT

FINISH FLOOR

BOT. OF

STRUCTURE

G7a

SEALANT

TILE IN WET

LOCATIONS,REF

SHEET A110 & A111

IN WET LOCATIONS,

SUBSTITUTE

CEMENTITIOUS

BACKERBOARD FOR

GYP. BD.

TILE IN WET

LOCATIONS,REF

SHEET A110 & A111

IN WET LOCATIONS,

SUBSTITUTE

CEMENTITIOUS

BACKERBOARD FOR

GYP. BD.

TILE IN WET

LOCATIONS,REF

SHEET A110 & A111

IN WET LOCATIONS,

SUBSTITUTE

CEMENTITIOUS

BACKERBOARD FOR

GYP. BD.

TILE IN WET

LOCATIONS,REF

SHEET A110 & A111

IN WET LOCATIONS,

SUBSTITUTE

CEMENTITIOUS

BACKERBOARD FOR

GYP. BD.

TILE IN WET

LOCATIONS,REF

SHEET A110 & A111

CEILING LINE WHERE

APPLICABLE

(2) LAYERS 5/8" TYPE

"X" GYP. BD. EA. SIDE

3 5/8" STEEL STUD

FRM'G @ 16" o.c.

3 1/2" ACOUSTICAL

INSULATION

FIRE SAFE SEALANT

FINISH FLOOR

BOT. OF

STRUCTURE

G5d- 2HR

FIRE SAFE SEALANT

CEILING LINE WHERE

APPLICABLE

FINISH FLOOR

BOT. OF

STRUCTURE

G5b

* ALL PENETRATIONS

THROUGH WALL TO BE

FIRE CAULKED.

5/8" TYPE "X" GYP.

BD. ONE SIDE

3 5/8" STEEL STUD

FRM'G @ 16" o.c.

3 1/2" ACOUSTICAL

INSULATION

SEALANT

IN WET LOCATIONS,

SUBSTITUTE

CEMENTITIOUS

BACKERBOARD FOR

GYP. BD.

TILE IN WET

LOCATIONS,REF

SHEET A110 & A111

DEMO

EXISTING TO REMAIN

NEW STEEL STUD

EARTH

SAND

GRANULAR FILL/DRAINAGE MATERIAL

CONCRETE (ELEVATION/SECTION)

PRECAST CONC./P.C. PLASTER/CUT STONE

GROUT

CONCRETE MASONRY UNIT

RIGID INSULATION

STEEL

WOOD FRAMING OR BLOCKING

FINISH WOOD

TILE

ROOF INSULATION

BATT INSULATION

GLASS (ELEVATION/SECTION)

GYPSUM BOARD (ELEVATION/SECTION)

PARTICLE BOARD

ACOUSTICAL CEILING PANEL OR TILE

PLYWOOD

Department of Veterans Affairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

Approved: Project Director

TJW NPL

BUILDING SIX

SEAL:ARCHITECT/ENGINEER:

STRUCTURAL ENGINEER

BOB D. CAMPBELL

4338 BELLEVIEW AVENUE

KANSAS CITY, MO 64111

(816) 531-4144

MEP ENGINEER

WATSON ENGINEERING

1112 STATE ROUTE 434

OWEGO, NY 13827

(607) 223-4334

35% DESIGN SUBMISSION 11/21/2018

60% DESIGN SUBMISSION 1/25/2019

100% S

U B

M

IT

TA

L

90% DESIGN SUBMISSION 8/30/2019

90% DESIGN RESUBMISSION 10/23/2019

100% DESIGN SUBMISSION 12/11/2019

FIRE PROTECTION ENGINEER

CMG FIRE PROTECTION

10727 W/ 128 STREET

OVERLAND PARK, KS 66213

(913) 239-8900

100% R1 DESIGN SUBMISSION 1/24/2020

G201

INFORMATION

BEDFORD VAMC

MENTAL HEALTH

BEDFORD, MA

518-18-035

2020.01.24

ABBREVIATIONS GRAPHIC SYMBOLS PARTITION TYPES GENERAL NOTES

PARTITION DETAILS

wall legend

MATERIALS

VHABEDSanfoM Text Box

DEDUCT ALTERNATES

DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.

DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

262 SF

ELEC./STORAGE

957 SF

AREA

MAINTENANCE

SHOP

209 SF

ELE./STORAGE

71 SF

ELEC. OFFICE

325 SF

ELEC. BREAK

RM.

326 SF

MECHANICAL

282 SF

ELEVATOR

SHOP

272 SF

MCHIM

635 SF

MCHIM

1180 SF

CORRIDOR

127 SF

STAFF

RESTROOM

316 SF

LOCKER

ROOM

406 SF

MECHANICAL

SERVICE

ROOM

173 SF

MAIN

ELECTRICAL

ROOM

59 SF

VESTIBULE

374 SF

UNION OFFICE

211 SF

LOBBY

278 SF

ELEC.

85 SF

STORAGE

155 SF

OFFICE

160 SF

RESTROOM

133 SF

STAFF

RESTROOM

228 SF

STAIR

230 SF

STAIR

1464 SF

CARPENTER

SHOP

219 SF

BREAKROOM

90 SF

STORAGE

106 SF

CORRIDOR

1311 SF

TOOL ROOM

193 SF

STAIR

192 SF

STAIR

124 SF

STAIR

604 SF

CORRIDOR

835 SF

CORRIDOR

6 SF

IT

58 SF

ELEV.

75 SF

ELEV.

72 SF

MACHINE

ROOM

125 SF

STAIR

TMS

6.8"34

39" 195

4"20

39" 195

6.8"34

39" 195

6.8"34

39" 195

6.8"34

60" 300

IT

MECH

ELEVATOR &

SHAFT BY

OTHERS, NIC

GENERAL INFORMATION:

LOCATION: RESPONDING FIRE

DEPARTMENT:

AUTHORITIES HAVING

JURISDICTION:

BEDFORD VAMC MENTAL HEALTH

BUILDING 6

BEDFORD, MA

LOCAL FD HAVING JURISDICTION

DEPARTMENT OF VETERANS

AFFAIRS

PROJECT DESCRIPTION:

RENOVATION OF FIRST FLOOR FOR OUT-PATIENT MENTAL HEALTH SERVICES; NEW FINISH WORK IN LOWER LEVEL; LIMITED EXTERIOR REPAIR

INCLUDING ADDITION OF NEW ENTRY COVER ON WEST FACADE

APPLICABLE CODES

OCCUPANCY (Section 303) & STRUCTURAL CLASSIFICATION

Mixed Use Occupancy Lower Level: Business - occupancy unchanged Main Level: Business - Out-patient Mental Health Clinic Second Level: Healthcare - occupancy unchanged - In-patient Mental Health Care

BUILDING HEIGHT AND AREA:

Total Area per Floor:

Total Building Area:

13,543 sq. ft.

40,629 sq. ft.

WATER SUPPLY- FLOW TESTS:

Static:

Residual:

Flow:

Date: May 2018 Location: Hydrant #6

PASSIVE LIFE SAFETY SYSTEMS:

Corridor Ratings:

Stairwells:

Shafts:

Occupancy Separations:

Special Hazard Protection:

0 HR Required / 0 HR Provided (38.3.6.1(3)) 2 HR Required / 2 HR Provided 2 HR Required / 2 HR Provided 2 HR Required (separation from Health Care on 2nd Floor) / 2 HR Provided Automatic extinguishing system and non-rated smoke partitions - (storage rooms over 100 sq. ft. in accordance with 38.3.2.1

REGISTERED DESIGN PROFESSIONALS:

Tompkins Architects 1520 Clay St. Ste. A8 North Kansas City, MO 64116

ACTIVE LIFE SAFETY SYSTEMS:

Fire Alarm:

FACP:

Remote Annunciator Panel:

Smoke Detection:

MNS:

Exit Signs:

Egress Lighting:

Emergency Lights:

Backup Power:

Suppression- Standpipes:

Suppression- Automatic:

Fire Extinguishers:

Required/Provided per NFPA 101 & 72

Required/Provided Required/Provided Required/Provided Not Required/Provided Required/Provided Required/Provided Diesel Generator Required/Provided Not Required/ Not Provided Required/Provided per NFPA 13

Required/Provided

GENERAL BUILDING LIMITATIONS:

Construction NFPA Type II(111) (IBC Type II-A) Structural Fire Ratings Structural frame including columns, girders & trusses:

Bearing exterior walls:

Bearing interior walls:

Nonbearing exterior walls & partitions:

Nonbearing interior walls & partitions:

Floor construction including supporting beams & joists:

Roof construction including supporting beams & joists:

Shafts (connect 3 stories):

Table 601

1 HR

1 HR

1 HR

1 HR

0 HR

0 HR

0 HR

2 HR min.

Actual building area and height unchanged.

Total Building Height: 3 Stories - 43 ft.

50 psi 25 psi 517 gpm

PLUMBING FIXTURE COUNT MAIN LEVEL:

Occupancy Type

Occupant Load

Water Closet

Lavatory Drinking Fountain

Shower

B 272 6 5 3 -

Total Provided Fixtures

6 5 3 -Total Required Fixtures

9 9 3 0

All current codes, guidelines and standards according to the following:

VA Architectural Design Manual (2014) VA Mental Health Facilities Design Manual (2017) VA Fire Protection Design Manual (2015) PG 18-14 Room Finishes, Door, and Hardware Schedule (2017) PG-18-13 Barrier Free Design Standard PG-18-12 Mental Health Outpatient Services Design Guide VA Handbook H-18-8 Seismic Design Requirements Physical Security Design Manual International Building Code (2018)

Construction Type:

IBC - Type II-A (Fully Sprinklered) NFPA - Type II (111) (Fully Sprinklered) Seismic Category: C

EXISTING, NOT IN CONTRACT

2 HR RATED WALL CONSTRUCTION W/ 2

HR RATED OPENING ASSEMBLIES

FE

FIRE EXTINGUISHER

INTERIOR EXIT

EXTERIOR EXIT

OFFICE

600 SF

ROOM NAME

ROOM NUMBER

AREA IN SQUARE FEET

CODE LEGEND

ACCUMULATE EXIT WIDTH:

OCCUPANTS / EXIT WIDTH REQD

EXIT WIDTH PROVIDED / CAPACITY

198/39.6"

68"/340

NFPA Codes, Handbooks, Standards, etc. Including, but not limited to - NFPA 13 – Automatic Sprinkler Systems Handbook NFPA 20 – Stationary Fire Pumps NFPA 70 – National Electrical Code NFPA 70E – Standard for Electrical Safety in the Workplace NFPA 72 – National Fire Alarm and Signaling Code NFPA 75 – Standard for the Fire Protection of Information Technology Equipment NFPA 80 – Standard for Fire Doors and Opening Protectives NFPA 99 – Health Care Facilities NFPA 101 – Life Safety Code NFPA 110 – Standard for Emergency and Standby Power Systems NFPA 780 – Installation of Lightening Protection Systems

MEANS OF EGRESS:

Dead End Corridors shall not exceed 50 ft. - 38.2.5.2.1 Common Path of Travel shall not exceed 100 ft. - 38.2.5.3 Travel Distance shall not exceed 300 ft. - 38.2.6.2 (See Plan for actual distances)

NON PROTECTED EXIT PATH (EXEMPTION FOR FULLY

SPRINKLERED B OCCUPANCY ON LOWER LEVEL AND

MAIN LEVEL)

OCCUPANT LOAD

Lower Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants

Main Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants

Total Occupants: 272 occupants

Department of Veterans Affairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

Approved: Project Director

TJW NPL

BUILDING SIX

SEAL:ARCHITECT/ENGINEER:

STRUCTURAL ENGINEER

BOB D. CAMPBELL

4338 BELLEVIEW AVENUE

KANSAS CITY, MO 64111

(816) 531-4144

MEP ENGINEER

WATSON ENGINEERING

1112 STATE ROUTE 434

OWEGO, NY 13827

(607) 223-4334

35% DESIGN SUBMISSION 11/21/2018

60% DESIGN SUBMISSION 1/25/2019

100% S

U B

M

IT

TA

L

90% DESIGN SUBMISSION 8/30/2019

90% DESIGN RESUBMISSION 10/23/2019

100% DESIGN SUBMISSION 12/11/2019

FIRE PROTECTION ENGINEER

CMG FIRE PROTECTION

10727 W/ 128 STREET

OVERLAND PARK, KS 66213

(913) 239-8900

100% R1 DESIGN SUBMISSION 1/24/2020

G301

CODE REVIEW - LOWER

LEVEL

BEDFORD VAMC

MENTAL HEALTH

BEDFORD, MA

518-18-035

2020.01.24

1/8" = 1'-0"1 code review plan - lower level

N O

R T

H

LIMITED SCOPE OF WORK IN LOWER LEVEL:

COSMETIC UPGRADES TO INTERIOR CORRIDOR

SYSTEM AND RENOVATIONS TO ENTRY LOBBY, TMS

ROOM AND RESTROOMS. ALL OTHER EXISTING

WALLS, DOORS AND OTHER OPENINGS REMAIN.

GENERAL NOTE:

VHABEDSanfoM Text Box

DEDUCT ALTERNATES

DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.

DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

GENERAL INFORMATION:

LOCATION: RESPONDING FIRE

DEPARTMENT:

AUTHORITIES HAVING

JURISDICTION:

BEDFORD VAMC MENTAL HEALTH

BUILDING 6

BEDFORD, MA

LOCAL FD HAVING JURISDICTION

DEPARTMENT OF VETERANS

AFFAIRS

PROJECT DESCRIPTION:

RENOVATION OF FIRST FLOOR FOR OUT-PATIENT MENTAL HEALTH SERVICES; NEW FINISH WORK IN LOWER LEVEL; LIMITED EXTERIOR REPAIR

INCLUDING ADDITION OF NEW ENTRY COVER ON WEST FACADE

APPLICABLE CODES

OCCUPANCY (Section 303) & STRUCTURAL CLASSIFICATION

Mixed Use Occupancy Lower Level: Business - occupancy unchanged Main Level: Business - Out-patient Mental Health Clinic Second Level: Healthcare - occupancy unchanged - In-patient Mental Health Care

BUILDING HEIGHT AND AREA:

Total Area per Floor:

Total Building Area:

13,543 sq. ft.

40,629 sq. ft.

WATER SUPPLY- FLOW TESTS:

Static:

Residual:

Flow:

Date: May 2018 Location: Hydrant #6

PASSIVE LIFE SAFETY SYSTEMS:

Corridor Ratings:

Stairwells:

Shafts:

Occupancy Separations:

Special Hazard Protection:

0 HR Required / 0 HR Provided (38.3.6.1(3)) 2 HR Required / 2 HR Provided 2 HR Required / 2 HR Provided 2 HR Required (separation from Health Care on 2nd Floor) / 2 HR Provided Automatic extinguishing system and non-rated smoke partitions - (storage rooms over 100 sq. ft. in accordance with 38.3.2.1

REGISTERED DESIGN PROFESSIONALS:

Tompkins Architects 1520 Clay St. Ste. A8 North Kansas City, MO 64116

ACTIVE LIFE SAFETY SYSTEMS:

Fire Alarm:

FACP:

Remote Annunciator Panel:

Smoke Detection:

MNS:

Exit Signs:

Egress Lighting:

Emergency Lights:

Backup Power:

Suppression- Standpipes:

Suppression- Automatic:

Fire Extinguishers:

Required/Provided per NFPA 101 & 72

Required/Provided Required/Provided Required/Provided Not Required/Provided Required/Provided Required/Provided Diesel Generator Required/Provided Not Required/ Not Provided Required/Provided per NFPA 13

Required/Provided

GENERAL BUILDING LIMITATIONS:

Construction NFPA Type II(111) (IBC Type II-A) Structural Fire Ratings Structural frame including columns, girders & trusses:

Bearing exterior walls:

Bearing interior walls:

Nonbearing exterior walls & partitions:

Nonbearing interior walls & partitions:

Floor construction including supporting beams & joists:

Roof construction including supporting beams & joists:

Shafts (connect 3 stories):

Table 601

1 HR

1 HR

1 HR

1 HR

0 HR

0 HR

0 HR

2 HR min.

Actual building area and height unchanged.

Total Building Height: 3 Stories - 43 ft.

50 psi 25 psi 517 gpm

PLUMBING FIXTURE COUNT MAIN LEVEL:

Occupancy Type

Occupant Load

Water Closet

Lavatory Drinking Fountain

Shower

B 272 6 5 3 -

Total Provided Fixtures

6 5 3 -Total Required Fixtures

9 9 3 0

All current codes, guidelines and standards according to the following:

VA Architectural Design Manual (2014) VA Mental Health Facilities Design Manual (2017) VA Fire Protection Design Manual (2015) PG 18-14 Room Finishes, Door, and Hardware Schedule (2017) PG-18-13 Barrier Free Design Standard PG-18-12 Mental Health Outpatient Services Design Guide VA Handbook H-18-8 Seismic Design Requirements Physical Security Design Manual International Building Code (2018)

Construction Type:

IBC - Type II-A (Fully Sprinklered) NFPA - Type II (111) (Fully Sprinklered) Seismic Category: C

EXISTING, NOT IN CONTRACT

2 HR RATED WALL CONSTRUCTION W/ 2

HR RATED OPENING ASSEMBLIES

FE

FIRE EXTINGUISHER

INTERIOR EXIT

EXTERIOR EXIT

OFFICE

600 SF

ROOM NAME

ROOM NUMBER

AREA IN SQUARE FEET

CODE LEGEND

ACCUMULATE EXIT WIDTH:

OCCUPANTS / EXIT WIDTH REQD

EXIT WIDTH PROVIDED / CAPACITY

198/39.6"

68"/340

NFPA Codes, Handbooks, Standards, etc. Including, but not limited to - NFPA 13 – Automatic Sprinkler Systems Handbook NFPA 20 – Stationary Fire Pumps NFPA 70 – National Electrical Code NFPA 70E – Standard for Electrical Safety in the Workplace NFPA 72 – National Fire Alarm and Signaling Code NFPA 75 – Standard for the Fire Protection of Information Technology Equipment NFPA 80 – Standard for Fire Doors and Opening Protectives NFPA 99 – Health Care Facilities NFPA 101 – Life Safety Code NFPA 110 – Standard for Emergency and Standby Power Systems NFPA 780 – Installation of Lightening Protection Systems

MEANS OF EGRESS:

Dead End Corridors shall not exceed 50 ft. - 38.2.5.2.1 Common Path of Travel shall not exceed 100 ft. - 38.2.5.3 Travel Distance shall not exceed 300 ft. - 38.2.6.2 (See Plan for actual distances)

NON PROTECTED EXIT PATH (EXEMPTION FOR FULLY

SPRINKLERED B OCCUPANCY ON LOWER LEVEL AND

MAIN LEVEL)

OCCUPANT LOAD

Lower Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants

Main Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants

Total Occupants: 272 occupants

129 SF

OFFICE

112 SF

OFFICE

128 SF

OFFICE

106 SF

OFFICE

113 SF

OFFICE

146 SF

TREATMENT

121 SF

EXAM

152 SF

OFFICE

112 SF

OFFICE

110 SF

OFFICE

99 SF

OFFICE

101 SF

OFFICE

111 SF

OFFICE

114 SF

OFFICE

152 SF

TREATMENT

133 SF

POLICE

OUTPOST

STATION

574 SF

LARGE

GROUP

ROOM

365 SF

GROUP

THERAPY 2

259 SF

GROUP

THERAPY 3

129349 SF

GROUP

THERAPY 1

106 SF

OFFICE

157 SF

OFFICE

164 SF

STUDENT

TRAINING

98 SF

OFFICE

149 SF

OFFICE

137 SF

OFFICE

165 SF

TREATMENT

111 SF

OFFICE

312 SF

STAFF

LOUNGE

240 SF

TEAM

272 SF

RECEPTION

117 SF

EXAM

152 SF

TREATMENT

115 SF

OFFICE

110 SF

OFFICE

102 SF

OFFICE

179 SF

OFFICE

116 SF

OFFICE

150 SF

OFFICE

114 SF

OFFICE

110 SF

OFFICE

105 SF

OFFICE

112 SF

OFFICE

114 SF

SERVER

117 SF

OFFICE

61 SF

HAC

118 SF

OFFICE

86 SF

MEDICATION

85 SF

PATIENT

STORAGE

1/

1/

EXIT

TRAVEL

DISTANCE

= 98'

EXIT

TRAVEL

DISTANCE

= 98'

EXIT ACCESS

TRAVEL DISTANCE

= 72'

EXIT ACCESS

TRAVEL

DISTANCE

= 83'

EXIT

TRAVEL

DISTANCE

= 85'

8.8"44

34" 227

9.2"46

34" 227

9.2"46

34" 227

EGRESS THROUGH

INTERVENEING SPACES -

PERMITTED BY LSC 7.5.1.6

MAXIMUM OCCUPANCY

FOR THIS ROOM WILL

BE POSTED AS 49

DAU CLEAN

37 SF

CLOSET

356 SF

WAITING

AREA

72 SF

COMPUTER

RM

20 SF

CLOSET

DAU DIRTY

STAIR TOWER BY OTHERS

FE

FE

FE

FE

FE

FE

69 SF

STAFF

RESTROOM

72 SF

RESTROOM

39 SF

RESTROOM

46 SF

STAFF

RESTROOM

53 SF

RESTROOM

221 SF

ENTRY

66 SF

RESTROOM

59 SF

RESTROOM

18 SF

ELECTRICAL

89 SF

DAU

COLLECTION

RESTROOM

78 SF

STAFF

RESTROOM

57 SF

CORRIDOR

901 SF

CORRIDOR

721 SF

CORRIDOR

705 SF

CORRIDOR

152 SF

CORRIDOR

20 SF

ELECTRICAL

125 SF

STAIR

76 SF

ELEV.

58 SF

ELEV.

IT

8.8"44

34" 227

STAIR EXIT

13.2"44

48 160

ELEVATOR &

SHAFT BY

OTHERS, NIC

FE

Department of Veterans Affairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

Approved: Project Director

TJW NPL

BUILDING SIX

SEAL:ARCHITECT/ENGINEER:

STRUCTURAL ENGINEER

BOB D. CAMPBELL

4338 BELLEVIEW AVENUE

KANSAS CITY, MO 64111

(816) 531-4144

MEP ENGINEER

WATSON ENGINEERING

1112 STATE ROUTE 434

OWEGO, NY 13827

(607) 223-4334

35% DESIGN SUBMISSION 11/21/2018

60% DESIGN SUBMISSION 1/25/2019

100% S

U B

M

IT

TA

L

90% DESIGN SUBMISSION 8/30/2019

90% DESIGN RESUBMISSION 10/23/2019

100% DESIGN SUBMISSION 12/11/2019

FIRE PROTECTION ENGINEER

CMG FIRE PROTECTION

10727 W/ 128 STREET

OVERLAND PARK, KS 66213

(913) 239-8900

100% R1 DESIGN SUBMISSION 1/24/2020

G302

CODE REVIEW - MAIN LEVEL

BEDFORD VAMC

MENTAL HEALTH

BEDFORD, MA

518-18-035

2020.01.24

1/8" = 1'-0"1 code floor plan - main level

N O

R

VHABEDSanfoM Text Box

DEDUCT ALTERNATES

DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.

DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

A B C D E F G H I J K L M N O P Q R S T U V

7.9 7.5

6.5

3.9

E.9 H.1 Q.1J.1 L.9 N.9 R.1D.9

4.1

6.9

B.9 D.1 R.9 T.1

DOOR IN

TEMPORARY WALL

DOOR IN

TEMPORARY WALL

MAINTAIN EGRESS PATH

MAINTAIN EGRESS PATH

MAINTAIN ACCESS TO

UNION OFFICE DURING

CONSTRUCTION

ELEC./STORAGE

AREA

MAINTENANCE

SHOP

ELE./STORAGE

ELEC. OFFICE

ELEC. BREAK

RM.

ELEVATOR

SHOP

MCHIM

MCHIM

CORRIDOR

STAFF

RESTROOM

LOCKER

ROOM

MECHANICAL

SERVICE

ROOM

MAIN

ELECTRICAL

ROOM

VESTIBULE

UNION OFFICE

ELEC.

STORAGE

OFFICE

STAIR

STAIR

CARPENTER

SHOP

BREAKROOM

STORAGE

CORRIDOR

TOOL ROOM

STAIR

STAIR

STAIR

CORRIDOR

CORRIDOR

STAIR

ELEV.

STORAGE

RESTROOM

OFFICE

WHEELCHAIR STORAGE

STORAGE

MECH

TUNNEL TO

BUILDING 5

TUNNEL TO

BUILDING 7

ELECTRICAL

CLOSET

BOUNDARY OF WORK ZONE;

RETAIN EXISTING WALL

CURRENT PHASE WORK,

DEMOLITION & NEW CONSTRUCTION

NO WORK

2 HR RATED TEMPORARY WALL

1. MAINTAIN EGRESS PATHS.

2. MAINTAIN ACCESS TO UNION OFFICE 017.

3. PROVIDE SIGNAGE AS REQUIRED.

1. MAINTAIN EGRESS PATHS.

2. MAINTAIN ACCESS TO UNION OFFICE 017.

3. PROVIDE SIGNAGE PRIOR TO TUNNEL ACCESS FROM BUILDINGS 5 & 7.

A B C D E F G H I J K L M N O P Q R S T U V

7.9 7.5

6.5

3.9

E.9 H.1 Q.1J.1 L.9 N.9 R.1D.9

4.1

6.9

B.9 D.1 R.9 T.1

DOOR IN

TEMPORARY WALL

PHASE II-B

PHASE II-A

TUNNEL

TO

BUILDING

TUNNEL TO

BUILDING 7

ELEC./STORAGE

AREA

MAINTENANCE

SHOP

ELE./STORAGE

ELEC. OFFICE

ELEC. BREAK

RM.

MECHANICAL

ELEVATOR

SHOP

MCHIM

MCHIM

CORRIDOR

STAFF

RESTROOM

LOCKER

ROOM

MECHANICAL

SERVICE

ROOM

MAIN

ELECTRICAL

ROOM

VESTIBULE

UNION OFFICE

LOBBY

ELEC.

STORAGE

OFFICE

STAFF

RESTROOM

STAIR

014STAIR

CARPENTER

SHOP

BREAKROOM

STORAGE

CORRIDOR

TOOL ROOM

STAIR

STAIR

STAIR

CORRIDOR

CORRIDOR

STAIR

ELEV.

TMS

MECH

ELECTRICAL

DOOR IN

TEMPORARY WALL

DOOR IN

TEMPORARY WALL

IT

IT

ELEV.

MACHINE

ROOM

RESTROOM

1. MAIN LEVEL & SECOND LEVEL (N.I.C.) TO BE COMPLETED IN

SINGLE PHASE. AREAS WILL BE UNOCCUPIED DURING ENTIRETY OF

CONSTRUCTION.

2. LOWER LEVEL TO BE PARTIALLY OCCUPIED BY BOTH STAFF AND

PATIENTS.

3. MAINTAIN 2 HOUR FIRE SEPARATION BETWEEN CONSTRUCTION

AND OCCUPIED SPACES AT ALL TIMES. ALL TEMPORARY WALLS

TO BE 2 HR CONSTRUCTION AND EXTEND TO TOP OF DECK. ALL

EXISTING HVAC, PLUMBING, ELECTRICAL OR OTHER TO BE

COORIDNATED TO MAINTAIN FIRE RATING.

Department of Veterans Affairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

Approved: Project Director

TJW NPL

BUILDING SIX

SEAL:ARCHITECT/ENGINEER:

STRUCTURAL ENGINEER

BOB D. CAMPBELL

4338 BELLEVIEW AVENUE

KANSAS CITY, MO 64111

(816) 531-4144

MEP ENGINEER

WATSON ENGINEERING

1112 STATE ROUTE 434

OWEGO, NY 13827

(607) 223-4334

35% DESIGN SUBMISSION 11/21/2018

60% DESIGN SUBMISSION 1/25/2019

100% S

U B

M

IT

TA

L

90% DESIGN SUBMISSION 8/30/2019

90% DESIGN RESUBMISSION 10/23/2019

100% DESIGN SUBMISSION 12/11/2019

FIRE PROTECTION ENGINEER

CMG FIRE PROTECTION

10727 W/ 128 STREET

OVERLAND PARK, KS 66213

(913) 239-8900

100% R1 DESIGN SUBMISSION 1/24/2020

G401

PHASING PLANS

BEDFORD VAMC

MENTAL HEALTH

BEDFORD, MA

518-18-035

2020.01.24

3/32" = 1'-0"1 phasing plan - lower level - phase I

PHASING PLAN LEGEND

phase I general notes phase II-A & II-B general notes

3/32" = 1'-0"2 phasing plan - lower level - phase II phasing general notes

VHABEDSanfoM Text Box

DEDUCT ALTERNATES

DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.

DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).

GENERAL NOTES - STRUCTURAL

1. General Information

A. The contractor shall verify dimensions and conditions before construction and notify the engineer of any discrepancies, inconsistencies, or difficulties affecting the work before proceeding.

B. The contractor shall coordinate all disciplines, verifying size and location of all openings, whether shown on structural drawings or not, as called for on architectural, mechanical, or electrical drawings. In the case of work in an existing building the contractor shall scan existing structure to locate all rebar in the area of the new core/opening using ground penetrating radar and notify the engineer of record for review prior to coring/cutting. Conflicts, inconsistencies, or other difficulties affecting structural work shall be called to the architect or engineer's attention for direction before proceeding.

C. All design and construction work for this project shall conform to the requirements of the following governing design codes:

1.) International Building Code (IBC 2012) as amended by the city of Bedford. MA 2.) Minimum Design Loads for Buildings and Other Structures (ASCE7-10) 3.) Specification for Structural Steel Buildings (AISC 360-10)

Member Design Basis is Allowable Stress Design (ASD) Connection Design Basis is Allowable Stress Design (ASD)

4.) Structural Welding Code (AWS D1.3-98) 5.) Building Code Requirements for Structural Concrete (ACI 318-11) 6.) Building Code Requirements for Masonry Structures (ACI 530-11/TMS 402-11) 7.) North American Specification for the Design of Cold-Formed Steel Structural

Members (AISI S100-07/S1-1) 8.) National Design Specification (NDS) for Wood Constriction with 2012

Supplements (ANSI/AWC NDS-2012) 9.) Special Design Provisions for Wind and Seismic (AWC SDPWS-2008)

D. These drawings are for this specific project and no other use is authorized.

2. Structural Load Design Criteria

A. Stair Live = 100psf B. Roof Live = 20psf; Roof Collateral Dead = 10psf C. Snow: Pg = 50psf, Pf =35psf, Is = 1.0, Ce = 1.0, Ct = 1.0, Drift per ASCE/SEI 7 D. Lateral Loads:

1.) Wind: V = 136 mph, Exposure B Occupancy [Risk] Category II, Iw=1.0 GCpi=+/-0.18 Design wind pressures to be used for the design of exterior component and cladding materials on the designated zones of wall and roof surfaces shall be per section 30.7 and Table 30.7-2 of ASCE/SEI 7. Tabulated pressures shall be multiplied by effective area reduction factors, exposure adjustment factors, and topographic factors where applicable

2.) Seismic: Ss = 0.223, S1 = 0.071 Occupancy [Risk] Category II, Ie=1.0, Site Classification D; Sds = 0.238; Sd1 = 0.114 Seismic Design Category B Basic Seismic Force-resisting System:

E. This project is designed to resist the most critical effects resulting from the load combinations of section 1605.3 of the International Building Code.

3. Concrete

A. All concrete for foundations (walls, grade beams, footings and piers) shall develop minimum ultimate compressive design strength of 3500 psi in 28 days, but not less than 500 pounds of cement shall be used per cubic yard of concrete regardless of strengths obtained, not over 6 gallons of water per 100 pounds of cement and not over 4 inches of slump.

B. All concrete for interior flatwork shall develop minimum ultimate compressive design strength of 4000 psi in 28 days, but not less than 540 pounds of cement shall be used per cubic yard of concrete regardless of strengths obtained, not over 5.40 gallons of water per 100 pounds of cement and not over 4 inches of slump. Concrete mix shop drawing shall contain testing data proving concrete design mix shrinkage is less than 0.034% at 28 days when tested according to ASTM C157 (air drying method only).

C. All concrete for exterior flatwork shall have a minimum design compressive strength of 4500 psi in 28 days, with not less than 560 pounds of cement per cubic yard of concrete, not over 5 gallons of water per 100 pounds of cement, with 6% +/- 1% air entrainment, and a maximum of 4 inches of slump.

D. The preceding minimum mix requirements may have water-reducing admixtures conforming to ASTM C494 added to the mix at manufacturer's dosage rates for improved workability.

E. The preceding minimum mix requirements may have up to 15% maximum of the cement content replaced with an approved ASTM C618 Class C fly ash, provided the total minimum cementitious content is not reduced.

F. Combined aggregate (coarse plus fine) for all concrete shall be well graded from coarsest to finest with no more than 18 percent and not less than 8 percent retained on an individual sieve, except that less than 8 percent may be retained on coarsest sieve and on No. 50 and finer sieves. Submit this gradation report with the concrete mix design shop drawings.

G. All interior concrete slabs on grade shall be placed over 15 mil, Class A Vapor Barrier per ASTM E1745 with less than 0.01 perms, tested after mandatory conditioning. All joints shall be lapped and sealed per manufacturer's recommendations. All penetrations, as well as damaged vapor barrier material shall also be sealed per manufacturer's recommendation prior to concrete placement. Install barrier per manufacturer recommended details at all discontinuous edges (at interior columns, exterior edge of slab, etc.) to ensure terms of warranty are followed. The vapor barrier shall be placed over free-draining granular material as prescribed by the project soils report.

H. All concrete is reinforced concrete unless specifically called out as unreinforced.

Reinforce all concrete not otherwise shown with same steel as in similar sections or areas. Any details not shown shall be detailed per ACI 315 and meet requirements of ACI 318, current editions.

I. Control joints in dirt formed slab to be as shown on plans. Where not shown, limit controlled areas to not more than 144 square feet, or 12 feet on any side.

Slab panel side ratio shall not exceed 1 1/2 to 1.

J. Contractor shall verify that all concrete inserts, reinforcing and embedded items are correctly located and rigidly secured prior to concrete placement.

K. Construction joints in beams, slabs, and grade beams shall occur at midspan (middle third) unless noted otherwise. Provide 2 x 4 horizontal keys at construction joints for shear transfer.

L. No aluminum items shall be embedded in any concrete.

4. Reinforcing Steel

A. All reinforcing steel shall conform to the requirements of ASTM A615 or A706 grade 60 steel. Welded plain wire fabric shall be supplied in sheets and conform to the requirements of ASTM A185.

B. Clear minimum coverage of concrete over reinforcing steel shall be as follows:

1.) Concrete placed against earth: 3" 2.) Formed concrete against earth: 2" 3.) Slabs: 1" 4.) Beams or Columns: 1-1/2" 5.) Other 2" All coverage shall be nominal bar diameter minimum.

C. All dowels shall be the same size and spacing as adjoining main bars (splice lap 48 bar diameters or 24" minimum unless noted otherwise).

D. At corners of all walls, beams, and grade beams supply corner bars (minimum 2'-0" in each direction or 48 bar diameters) in outside face of wall, matching size and spacing of horizontal bars.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .