This document is a request for proposals for renovating an outpatient mental health clinic. The solicitation involves projects 518-18-001 and 518-18-035 to correct mental health deficiencies at a Veterans Affairs medical center in Bedford, Massachusetts. Contractors must furnish all labor, materials, equipment, transportation, and supervision to complete construction according to drawings, specifications, and applicable attachments. The technical representative is Michael Sanford and administrative contracting officer is Richard Coutermarsh. The estimated value is between $10-20 million. This solicitation is 100% set aside for service-disabled veteran-owned small businesses. To be eligible for award, offerors must be verified as SDVOSBs by the Center for Veteran Enterprise and VetBiz at time of proposal submission and award. A site visit is scheduled for July 29, 2020, with proposals due by September 4, 2020.
View the file
Other files
Show 40 more
Latest 50 of 60 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION: BUILDING #6
GENERAL INFORMATION:
LOCATION: RESPONDING FIRE
DEPARTMENT:
AUTHORITIES HAVING
JURISDICTION:
BEDFORD VAMC MENTAL HEALTH
BUILDING 6
BEDFORD, MA
BEDFORD, MASSACHUSETTS FIRE
DEPARTMENT
DEPARTMENT OF VETERANS
AFFAIRS
PROJECT DESCRIPTION:
RENOVATION OF FIRST FLOOR FOR OUT-PATIENT MENTAL HEALTH SERVICES; NEW FINISH WORK IN LOWER LEVEL; LIMITED EXTERIOR REPAIR
INCLUDING ADDITION OF NEW ENTRY COVER ON WEST FACADE
APPLICABLE CODES
OCCUPANCY (Section 303) & STRUCTURAL CLASSIFICATION
Lower Level: Business - occupancy unchanged Main Level: Business - Out-patient Mental Health Clinic Second Level: Healthcare - occupancy unchanged - In-patient Mental Health Care
BUILDING HEIGHT AND AREA:
Total Area per Floor:
Total Building Area:
13,543 sq. ft.
40,629 sq. ft.
3 Stories - 43'
All current codes, guidelines and standards according to the following:
VA Architectural Design Manual (2014) VA Mental Health Facilities Design Manual (2017) VA Fire Protection Design Manual (2015) PG 18-14 Room Finishes, Door, and Hardware Schedule (2017) PG-18-13 Barrier Free Design Standard PG-18-12 Mental Health Outpatient Services Design Guide VA Handbook H-18-8 Seismic Design Requirements Physical Security Design Manual International Building Code (2018)
Construction Type:
IBC - Type II-A NFPA - Type II (111) Seismic Category: C
NFPA Codes, Handbooks, Standards, etc. Including, but not limited to - NFPA 13 – Automatic Sprinkler Systems Handbook NFPA 20 – Stationary Fire Pumps NFPA 70 – National Electrical Code NFPA 70E – Standard for Electrical Safety in the Workplace NFPA 72 – National Fire Alarm and Signaling Code NFPA 75 – Standard for the Fire Protection of Information Technology Equipment NFPA 80 – Standard for Fire Doors and Opening Protectives NFPA 99 – Health Care Facilities NFPA 101 – Life Safety Code NFPA 110 – Standard for Emergency and Standby Power Systems NFPA 780 – Installation of Lightening Protection Systems
PROJECT LOCATION
MIDDLESEX
COMMUNITY
COLLEGE
EDITH NOURSE
ROGERS
MEMORIAL
HARTWELL
TOWN FOREST
BEDFORD
ELM BROOK
CONSERVATION
AREA
HANSCOM AFB
PINE MEADOWS
COUNTRY CLUB
H MART BURLINGTON
BURLINGTON MALL
BURLINGTON
LANDLOCKED
FOREST
VINE BROOK
WELLFIELD
INTERSTATE
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
TJW NPL
100%
S U
B M
IT
TA
L
SEAL:ARCHITECT/ENGINEER:
35% DESIGN SUBMISSION 11/21/2018
DRAWING INDEX
BUILDING SIX
60% DESIGN SUBMISSION 1/25/2019
90% DESIGN SUBMISSION 8/30/2019
90% DESIGN RESUBMISSION 10/23/2019
100% DESIGN SUBMISSION 12/11/2019
STRUCTURAL ENGINEER
BOB D. CAMPBELL
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
MEP ENGINEER
WATSON ENGINEERING
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
FIRE PROTECTION ENGINEER
CMG FIRE PROTECTION
10727 W/ 128 STREET
OVERLAND PARK, KS 66213
(913) 239-8900
100% R1 DESIGN SUBMISSION 1/24/2020
G101
TITLE SHEET
BEDFORD VAMC MENTAL HEALTH
518-18-035
BEDFORD, MA
BEDFORD VAMC
MENTAL HEALTH
BEDFORD, MA
518-18-035
2020.01.24
LOCATION MAP
INFORMATION
G101 TITLE SHEET
G201 INFORMATION
G301 CODE REVIEW - LOWER LEVEL
G302 CODE REVIEW - MAIN LEVEL
G401 PHASING PLANS
NORTH
ARCHITECTURAL
D101 DEMOLITION PLAN - LOWER LEVEL
D102 DEMOLITION PLAN - MAIN LEVEL
D103 DEMOLITION PLAN - ROOF
A001 ARCHITECTURAL SITE PLAN
A002 SITE DETAILS
A101 ARCHITECTURAL FLOOR PLAN - LOWER LEVEL
A102 ARCHITECTURAL FLOOR PLAN - MAIN LEVEL
A110 ENLARGED FLOOR PLANS - LOWER LEVEL
RESTROOMS
A111 ENLARGED FLOOR PLANS - MAIN LEVEL
RESTROOMS
A201 EXTERIOR ELEVATIONS
A202 EXTERIOR ELEVATIONS
A203 EXTERIOR ELEVATIONS
A204 EXTERIOR ELEVATION DETAILS
A301 BUILDING SECTIONS
A302 WALL SECTIONS
A310 DETAILS
A311 INTERIOR COLUMN DETAILS
A320 STAIR DETAILS
A321 STAIR DETAILS
A401 ARCHITECTURAL ROOF PLAN
A402 ROOF DETAILS
A501 DOOR, FRAME, & WINDOW SCHEDULES
A502 DOOR, FRAME, & WINDOW DETAILS
A601 REFLECTED CEILING PLAN - LOWER LEVEL
A602 REFLECTED CEILING PLAN - MAIN LEVEL
A701 FINISH FLOOR PLAN - LOWER LEVEL
A702 FINISH FLOOR PLAN - MAIN LEVEL
A703 FINISH SCHEDULE
FE101 FIXED EQUIPMENT PLAN - LOWER LEVEL
FE102 FIXED EQUIPMENT PLAN - MAIN LEVEL
FE201 FIXED EQUIPMENT PLAN - ENLARGED FLOOR PLANS
FE202 FIXED EQUIPMENT ELEVATIONS
FE203 FIXED EQUIPMENT ELEVATIONS
FE301 SIGNAGE SCHEDULE & DETAILS
FE302 EQUIPMENT SCHEDULES
PLUMBING
P001 PLUMBING ABBREVIATIONS & SYMBOLS
PD101 EXISTING & DEMO LOWER LEVEL PLUMBING PLAN
PD102 EXISTING & DEMO MAIN LEVEL PLUMBING PLAN
MECHANICAL
M001 MECHANICAL ABBREVIATIONS & SYMBOLS
MD101 EXISTING & DEMO LOWER LEVEL HVAC PLAN
MD102 EXISTING & DEMO MAIN LEVEL HVAC PLAN
E101 PROPOSED LOWER LEVEL ELECTRICAL PLAN
E102 PROPOSED FIRST FLOOR ELECTRICAL PLAN
E103 PROPOSED LOWER LEVEL LIGHTING PLAN
E104 PROPOSED MAIN LEVEL LIGHTING PLAN
E105 PROPOSED LOWER LEVEL LOW VOLTAGE
ELECTRICAL PLAN
E106 PROPOSED MAIN LEVEL LOW VOLTAGE ELECTRICAL
PLAN
E501 ELECTRICAL DETAILS
E601 EXISTING & DEMO ELECTRICAL ONE-LINE DIAGRAM
E602 PROPOSED ELECTRICAL ONE-LINE DIAGRAM
E603 ELECTRICAL SCHEDULES
E604 PANEL SCHEDULES
E605 ELECTRICAL RISER DIAGRAM
M101 PROPOSED LOWER LEVEL HVAC PLAN
M102 PROPOSED MAIN LEVEL HVAC PLAN
MP101 PROPOSED LOWER LEVEL HVAC PIPING PLAN
MP102 PROPOSED MAIN LEVEL HVAC PIPING PLAN
M401 TYPICAL AHU SECTION VIEW
M501 MECHANICAL DETAILS
M502 MECHANICAL DETAILS
M503 MECHANICAL DETAILS
M601 MECHANICAL SCHEDULES
M602 MECHANICAL SCHEDULES
M603 MECHANICAL SCHEDULES
M604 MECHANICAL SCHEDULES
M605 PSYCHROMETRIC CHARTS
M606 AHU CONTROLS SCHEMATIC & POINTS LIST
M607 HVAC CONTROLS SCHEMATIC & POINTS LIST
MEP INFORMATION
MEP100 MEP CODE ANALYSIS & GENERAL NOTES
ELECTRICAL
E001 ELECTRICAL ABBREVIATIONS & SYMBOLS
ED101 EXISTING & DEMO LOWER LEVEL ELECTRICAL PLAN
ED102 EXISTING & DEMO MAIN LEVEL ELECTRICAL PLAN
P101 PROPOSED LOWER LEVEL PLUMBING PLAN
P102 PROPOSED MAIN LEVEL PLUMBING PLAN
P501 PLUMBING DETAILS
P601 PLUMBING RISER DIAGRAMS
PROJECT INFORMATION
VICINITY MAP
NORTH
STRUCTURAL
S001 GENERAL NOTES
S100 CANOPY PLANS AND SECTIONS
S101 STAIR FRAMING PLAN AND SECTIONS
FIRE PROTECTION
FA101 FIRE ALARM FLOOR PLAN - LOWER LEVEL
FA102 FIRE ALARM FLOOR PLAN - MAIN LEVEL
FA202 FIRE ALARM DETAILS
FX100 FIRE SPRINKLER FLOOR PLAN - LOWER LEVEL
EXISTING
FX101 FIRE SPRINKLER FLOOR PLAN - LOWER LEVEL NEW
WORK
FX102 FIRE SPINKLER EXISTING PLAN - MAIN LEVEL
FX103 FIRE SPINKLER FLOOR PLAN - MAIN LEVEL
VHABEDSanfoM Text Box
DEDUCT ALTERNATES
DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.
DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
NOTE: REFER TO SPECIFICATIONS FOR
ADDITIONAL ABBREVIATIONS OF REFERENCED
STANDARDS, REGULATORY AGENCIES,
ASSOCIATIONS AND OTHERS
A.B ANCHOR BOLT
ABV ABOVE
AD ACTUAL DIMENSION, ACCESS
DOOR
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANCH ANCHOR
ANGLE
ARCH ARCHITECTURAL
@ AT
AVG R AVERAGE "R" FACTOR FOR
INSULATION
B/C BACK OF CURB
BD BOARD
BLDG BUILDING
BM BEAM
BM BENCH MARK
BRG BEARING
BTM BOTTOM
BUR BUILT-UP ROOFING
CABT CABINET
CB CATCH BASIN
CH COAT HOOK
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CENTER LINE
CLG CEILING
CMU CONCRETE MASONRY UNIT
CMT CERAMIC MOSAIC TILE
CMP CORRUGATED METAL PIPE
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
COND CONDITION
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE
CR1 COMMUNICATIONS RISER
CTSK COUNTERSUNK
CUH CABINET UNIT HEATER
DBL DOUBLE
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DR DOOR
DWG DRAWING
DWG(S) DRAWING (S)
DS(0) DOWNSPOUT (OUTLET)
DTL DETAIL
E EAST
EA EACH
EC ELECTRICAL CONTRACTOR
EF EACH FACE
EJ EXPANSION JOINT
ELEC ELECTRICAL
EL, ELEV ELEVATION
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
E.W. EACH WAY
EXP EXPANSION
EXT EXTERIOR, EXTERNAL
EXIST,EX EXISTING
FA FRESH AIR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFCO FLUSH FLOOR CLEANOUT
FH FLAT HEAD
FHC FIRE HOSE CABINET
FIN FINISH
F FLOWLINE
FL,FLR FLOOR
FLRG FLOORING
FND FOUNDATION
FOS FACE OF STRUCTURE
FR FIRE RATED, FIRE RESISTIVE
FS FLOOR SINK, FOOD SERVICE
FT FEET OF FOOT
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GFRC GLASS FIBER REINFORCED
CONCRETE
GI GALVANIZED IRON
GL GLASS
GYP GYPSUM
HB HOSE BIBB
HC HANDICAPPED (ACCESSIBLE)
HD HAND DRYER
HDWE HARDWARE
HD WD HARD WOOD
HM HOLLOW METAL
HT HEIGHT
HORIZ HORIZONTAL, HORIZONTALLY
HPL HIGH PRESSURE LAMINATE
HR HOUR
HVAC HEATING VENTILATING & AIR
CONDITIONING
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
INTERM INTERMEDIATE
JB JUNCTION BOX
JT(S) JOINT(S)
LB LOCKER BENCH
LCS LIQUID CAULK SURFACE
LLV LONG LEG VERTICAL
LT WT LIGHTWEIGHT
LT LIGHT
LWCMU LIGHTWEIGHT CONCRETE
MASONRY UNIT
MAS MASONRY
MAT, MATL MATERIAL
MAX MAXIMUM
MB MACHINE
MC MECHANICAL CONTRACTOR
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL, MECHANISM
MFGR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MS MACHINE SCREW
MTL METAL
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO,# NUMBER
NOM NOMINAL
NTS NOT TO SCALE
NWCMU NORMAL WEIGHT CONCRETE
MASONRY UNIT
OA OVERALL
OC(S) ON CENTER
(STAGGERED, IF 2 ROWS)
OD OVERFLOW DRAIN
OFF OFFICE
OPER OPERATOR, OPERABLE, OPERATING
OPNG OPENING
OTO OUT-TO OUT
OZ OUNCE
PARTN PARTITION
PBD PARTICLE BOARD
PC PORTLAND CEMENT, PIECE
PERIM PERIMETER
PL PLATE
PLAM PLASTIC LAMINATE
PNL PANEL
PWD PLYWOOD
PR PAIR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVMT PAVEMENT
QTY QUANTITY
QT QUARRY TILE
R&R REMOVE & REPLACE
R RADIUS
RA RETURN AIR
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFER TO, REFERENCE
REFL REFLECTED
REINF REINFORCING, REINFORCED
REQ'D REQUIRED
REV REVERSED
RJ RUSTICATION JOINT
RMS ROOMS
RO ROUGH OPENING
RTU ROOF TOP UNIT
S SOUTH
SAN SANITARY
SC SAWCUT
SD SOAP DISPENSER
SECT SANITARY
SF SQUARE FOOT
SFCMU SPLIT FACE CONCRETE MASONRY
UNIT
SHT SHEET
SIM SIMILAR
SLV SHORT LEG VERTICAL
SMS SHEET METAL SCREWS
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENSION
SYM SYMMETRICAL
TB TACKBOARD
TD TOWEL DISPENSER & DISPOSER
(PAPER); OR TRENCH DRAIN
T & G TONGUE AND GROOVE
TEMP TEMPERED, TEMPORARY
TEXT TEXTURED
THK THICK
TLT TOILET
TOC TOP OF CURB OR CONCRETE
TOS TOP OF SLAB, STEEL OR
STRUCTURE
TP TOILET PAPER DISPENSER
TPL TWO PERSON LOCKER
TWS TACTILE WARNING SURFACE
TXFR TRANSFORMER
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
US URINAL SCREEN
V.C.P. VITEOUS CLAY PIPE
V.C.T. VINYL COMPOSITION TILE
VERT. VERTICAL, VERTICALLY
V.W.C. VINYL WALL COVERING
W WEST
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITH OUT
WO WHERE OCCURS
WT WEIGHT
WWF WELDED WIRE FABRIC
WPG WATERPROOFING
SECTION MARK- 1 = DETAIL NUMBER
A1.1 = SHEET NUMBER
INTERIOR ELEVATION MARKER:
A2.2 = SHEET NUMBER
6 = DETAIL NUMBER
BUILDING ELEVATION MARKER:
A2.1 = SHEET NUMBER
6 = DETAIL NUMBER
Note: REF. SITE PLAN LEGEND, ROOF PLAN LEGEND AND CEILING PLAN
LEGEND FOR ADDITIONAL NOTES AND LEGENDS.
BUILDING SECTION
ALUMINUM FRAME MARK -
REFERENCE FRAME ELEVATIONS
COLUMN GRID NUMBERS AND/OR LETTERS
D.F.(2)D.F
LEVEL 1
0'-0"
A1.1
SIM
A1.1
SIM
WALL SECTION
A2.1 6
EXISTING DOOR - UNMODIFIED
EXISTING DOOR - MODIFIED
NEW DOOR
EXPANSION JOINT
CONTROL JOINT
SAWCUT CONCRETE FLOOR JOINTS- REFERENCE
STRUCTURAL DRAWINGS FOR EXACT LOCATIONS
NEW FINISH SPOT ELEVATIONS IN FEET AND INCHES
(OR ON SITE PLAN IN FEET AND DECIMALS)
EXISTING SPOT ELEVATION
DOOR MARK - REFERENCE DOOR AND
FRAME SCHEDULE
LOCATION OF SYMBOL ON PAIR OF
DOORS INDICATES THE ACTIVE LEAF
LOCKERS: X INDICATES FILLER UNITS
PARTITION MARK - REFERENCE PARTITION
SCHEDULE
( ) INDICATES FIRE RATING OF WALL IN HOURS
PLAN NOTES
DETAIL MARKS: 1 = DETAIL NUMBER
A1.1 = SHEET NUMBER
SIM = SIMILAR
EQUIPMENT OR FURNISHINGS SHOWN ON FLOOR
PLANS. INDICATES FURNISHINGS BY OWNER (N.I.C.)
ON FIXED EQUIPMENT PLANS
ELEVATION MARK IN FEET AND INCHES
CASEWORK DESIGNATION; NUMBER INDICATES UNIT
NUMBER IDENTIFIED IN MANUFACTURED CASEWORK
SCHEDULE. REFERENCE SPECIFICATIONS.
GLASS TYPE - REFERENCE GLASS
SCHEDULE ON SHEET A501
FLOOR DRAIN (ELEVATION IN FEET AND
INCHES WHERE INDICATED)
MOP/JANITOR SINK
WATERCLOSET, URINAL, LAVATORY
(RESPECTIVELY)
DRINKING FOUNTAIN - REFERENCE
PLUMBING
A2.2
A1
C J
E J
S C
100'-0"
100'-0"
M12a(3)
1i
FURNITURE TAG, WHEN FURNITURE IS
INCLUDED IN CONTRACT
FD FD
99'-10"
COLUMN
GYPSUM BOARD GENERAL NOTES
G2a
GYPSUM
GYPSUM BOARD PARTITION:
1 5/8" STEEL STUD FURRING @ 16" OC - COVER ONE SIDE WITH
5/8" TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO 4" ABOVE
CEILING.
REFER TO PARTITION DETAILS BELOW
UNLESS NOTED OTHERWISE, EXTEND GYPSUM BOARD 4"
ABOVE FINISHED CEILING ELEVATION.
UNLESS NOTED OTHERWISE, PROVIDE 3 1/2" ACOUSTICAL
INSULATION IN ALL PARTITIONS.
FRAME AROUND DUCTWORK, BACK BRACE AS REQUIRED
FOR STABILITY.
REFER TO HOLLOW METAL FRAME DETAILS FOR
ADDITIONAL DETAIL REQUIREMENTS.
EXTEND STUDS TO TOP RUNNER ATTACHED TO
STRUCTURE ABOVE, OR BACK BRACE TO STRUCTURE AS
NECESSARY TO FULLY STABILIZE THE PARTITIONS.
REFER TO COLUMN DETAILS FOR ADDITIONAL DETAIL
REQUIREMENTS.
REFER TO FINISH SCHEDULE FOR WALL FINISH.
ALL PENETRATIONS THROUGH GYPSUM BOARD
PARTITIONS EXPOSED TO VIEW WILL BE TRIMMED NEAT
AND TRUE AND SEALED.
GYPSUM BOARD PARTITION:
3 5/8" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH 5/8"
TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO UNDERSIDE
OF DECK AND FILL VOIDS WITH 3 1/2" ACOUSTICAL INSULATION.
PROVIDE FIRE BLOCKING WHEN OVER 12'-0".
G5a
GYPSUM BOARD PARTITION:
3 5/8" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH 5/8"
TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO 4" ABOVE
CEILING. PROVIDE FIRE BLOCKING WHEN OVER 12'-0".
G5b
EXISTING
G3a GYPSUM BOARD PARTITION:
2 1/2" STEEL STUD FURRING @ 16" OC - 1" GAP BETWEEN EXISTING AND
NEW. COVER ONE SIDE WITH 5/8" TYPE "X" GYPSUM BOARDS. FILL WITH
CLOSED CELL SPRAY APPLIED INSUL. - 3" MIN. EXTEND PARTITION TO
UNDERSIDE OF DECK.
1"
EXISTING
GYPSUM BOARD PARTITION:
3 5/8" STEEL STUDS @ 16" OC - COVER ONE SIDE WITH 5/8"
TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO 4" ABOVE
CEILING. PROVIDE FIRE BLOCKING WHEN OVER 12'-0".
G5c
GYPSUM BOARD PARTITION:
6" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH 5/8" TYPE "X"
GYPSUM BOARDS. EXTEND PARTITION TO UNDERSIDE OF DECK
AND FILL VOIDS WITH 5 1/2" ACOUSTICAL INSULATION.
G7a
GYPSUM BOARD PARTITION:
3 5/8" STEEL STUDS @ 16" OC - COVER EACH SIDE WITH (2)
LAYERS 5/8" TYPE "X" GYPSUM BOARDS. EXTEND PARTITION TO
UNDERSIDE OF DECK AND FILL VOIDS WITH 3 1/2" ACOUSTICAL
INSULATION. FIRE RATED PARTITION - UL #U419; 2HR RATING
G5d
GYPSUM BOARD PARTITION:
3 5/8" STEEL STUDS @ 16" OC - COVER ONE SIDE WITH 5/8" TYPE
"X" GYPSUM BOARDS. EXTEND PARTITION TO UNDERSIDE OF
DECK. PROVIDE FIRE BLOCKING WHEN OVER 12'-0".
G5e
1. GENERAL CONTRACTOR SHALL NOTIFY THE VA PROJECT ENGINEER/COR
OF ANY DISCREPANCIES BETWEEN SPECIFICATIONS AND DRAWINGS,
BETWEEN MULTIPLE SPECIFICATION SECTIONS AND/OR BETWEEN
MULTIPLE DRAWINGS. THE VA PROJECT ENGINEER WILL DETERMINE
WHICH SHALL GOVERN. THE MOST RESTRICTIVE OR ANTICIPATED BY
CODE WILL BE THE DEFAULT.
2. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS OF THE JOB SITE INCLUDING UTILITIES AND EXISTING
STRUCTURES PRIOR TO BEGINNING WORK AND REPORT ANY
DISCREPANCIES TO THE VA PROJECT ENGINEER/COR.
3. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR STABILITY OF THE
STRUCTURE DURING CONSTRUCTION INCLUDING ALL SHORING AND
BRACING REQUIRED TO RESIST REQUIRED VERTICAL AND LATERAL
FORCES. ALL ACTIVITIES INVOLVING THE EXISTING STRUCTURE REQUIRE
SIGN-OFF BY A LICENCED STRUCTURAL ENGINEER.
4. ALL ARCHITECTURAL FLOOR PLAN DIMENSIONS ARE FROM FACE OF
CONCRETE, MASONRY AND STEEL STUD.
5. HORIZONTAL MASONRY DIMENSIONS FROM OUTSIDE TO OUTSIDE
CORNERS ARE ACTUAL. WHEN DIMENSIONS ARE 2'-8" OR LESS,
CONSTRUCT ONE JOINT LESS THAN DIMENSION SHOWN.
6. GYPSUM BOARD PARTITIONS ARE TYPE G5a UNLESS INDICATED
OTHERWISE.
7. GENERAL CONTRACTOR SHALL PROVIDE 3½” HIGH CONCRETE CURBS AT
ALL ELECTRICAL PANELS AND WHERE 2 OR MORE CONDUITS ARE
EXPOSED AT THE FLOOR LINE.
8. MECHANICAL /ELECTRICAL CONTRACTOR SHALL SIZE AND GENERAL
CONTRACTOR SHALL FORM, DOWEL AND POUR INTERIOR AND EXTERIOR
BASES FOR MECHANICAL AND ELECTRICAL EQUIPMENT (3½” AT INTERIOR
LOCATIONS AND 4” AT EXTERIOR LOCATIONS UNLESS INDICATED
OTHERWISE). REFER TO GENERAL PROVISIONS OF MECHANICAL
SPECIFICATIONS FOR MINIMUM SIZES. UNLESS INDICATED OTHERWISE,
REINFORCE WITH 4”x4” – W4.0xW4.0 WWF.
9. NO WALL FINISH OTHER THAN PAINT IS REQUIRED BEHIND CABINETS,
CHALKBOARDS, TACKBOARDS, ETC UNLESS WALL BEHIND IS EXPOSED
TO VIEW AND/OR WHERE NOTED OTHERWISE.
10. PROVIDE WALL BASE AT ALL CABINETS, SHELVING AND COLUMNS; AND
AS SCHEDULED.
11. PROVIDE LINTELS (REF. STRUCTURAL AND MISC. LINTEL SCHEDULE) FOR
ALL OPENINGS IN MASONRY WALLS FOR FIRE EXTINGUISHER CABINETS,
LOUVERS, GRILLES, DOORS, ETC.
12. GROUT SMOOTH ALL CONCRETE COLUMNS AND WALLS PRIOR TO
PAINTING. GROUT CONCRETE TO BE PAINTED WITH DRYWALL COMPOUND.
CONCRETE COLUMNS AND WALLS SCHEDULED NOT TO BE PAINTED,
GROUT WITH CEMENTITIOUS MATERIAL TO MATCH CONCRETE.
13. CONTINUE CONTROL JOINTS, INCLUDING SEALANTS, ABOVE CEILING
ELEVATIONS FOR FULL HEIGHT OF WALL OR PARTITION.
14. CONSTRUCT ALL MASONRY PARTITIONS THAT EXTEND TO THE
UNDERSIDE OF STRUCTURE WITH A ¾” CLEARANCE AROUND ALL
STRUCTURE AND FILL VOIDS WITH SAFING INSULATION, UNLESS NOTED
OTHERWISE.
15. PROVIDE 6" STEEL BLOCKING IN GYPSUM BOARD PARTITIONS BEHIND
CASEWORK. BLOCK AT TOP OF BASE UNITS, TOP & BOTTOM OF WALL
UNITS, TOP AND MID-HEIGHT OF TALL UNITS. PROVIDE 6" STEEL
BLOCKING IN GYPSUM BOARD PARTITIONS BEHIND GRAB BARS, DOOR
STOPS, WALL- MOUNTED SHELVING, WALL-MOUNTED TV’S AND OTHER
LOCATIONS AS SPECIFIED OR NOTED. CUT TO FIT SNUGLY BETWEEN
STUDS & KERF AT STUD FLANGES TO FIT FIRMLY TO BACK OF DRYWALL.
16. REFER TO STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR
REINFORCING STEEL IN MASONRY WALLS AND POURED CONCRETE.
17. REFER TO CODE COMPLIANCE PLANS FOR FIRE RATINGS OF PARTITIONS
AND SMOKE BARRIER LOCATIONS. GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR CONSTRUCTION OF PARTITIONS AND BARRIERS TO
COMPLY WITH RATINGS INDICATED.
18. CONTRACTOR TO FIRESTOP ALL EXISTING AND NEW PENETRATIONS IN
ALL FIRE RATED WALLS AND FLOORS.
CEILING LINE WHERE
APPLICABLE
5/8" TYPE "X" GYP.
BD. EA. SIDE
3 5/8" STEEL STUD
FRM'G @ 16" o.c.
3 1/2" ACOUSTICAL
INSULATION
SEALANT
FINISH FLOOR
BOT. OF
STRUCTURE
IN WET LOCATIONS,
SUBSTITUTE
CEMENTITIOUS
BACKERBOARD FOR
GYP. BD.
CEILING LINE WHERE
APPLICABLE
5/8" TYPE "X" GYP.
BD. ONE SIDE
1 5/8" STEEL STUD
FRM'G @ 16" o.c.
1 1/2" ACOUSTICAL
INSULATION
SEALANT
FINISH FLOOR
BOT. OF
STRUCTURE
G5aG2a
CEILING LINE WHERE
APPLICABLE
5/8" TYPE "X" GYP.
BD. ONE SIDE
2 1/2"" STEEL STUD
FRM'G @ 16" o.c.
CLOSED CELL
SPRAY APPLIED
INSULATION - 3" MIN.
SEALANT
FINISH FLOOR
BOT. OF
STRUCTURE
G3a
SEALANT
1"
SEALANT
EXISTING EXTERIOR
WALL
CEILING LINE WHERE
APPLICABLE
5/8" TYPE "X" GYP.
BD. ONE SIDE
3 5/8" STEEL STUD
FRM'G @ 16" o.c.
3 1/2" ACOUSTICAL
INSULATION
SEALANT
FINISH FLOOR
BOT. OF
STRUCTURE
G5c
CEILING LINE WHERE
APPLICABLE
5/8" TYPE "X" GYP.
BD. EA. SIDE
6" STEEL STUD
FRM'G @ 16" o.c.
5 1/2" ACOUSTICAL
INSULATION
SEALANT
FINISH FLOOR
BOT. OF
STRUCTURE
G7a
SEALANT
TILE IN WET
LOCATIONS,REF
SHEET A110 & A111
IN WET LOCATIONS,
SUBSTITUTE
CEMENTITIOUS
BACKERBOARD FOR
GYP. BD.
TILE IN WET
LOCATIONS,REF
SHEET A110 & A111
IN WET LOCATIONS,
SUBSTITUTE
CEMENTITIOUS
BACKERBOARD FOR
GYP. BD.
TILE IN WET
LOCATIONS,REF
SHEET A110 & A111
IN WET LOCATIONS,
SUBSTITUTE
CEMENTITIOUS
BACKERBOARD FOR
GYP. BD.
TILE IN WET
LOCATIONS,REF
SHEET A110 & A111
IN WET LOCATIONS,
SUBSTITUTE
CEMENTITIOUS
BACKERBOARD FOR
GYP. BD.
TILE IN WET
LOCATIONS,REF
SHEET A110 & A111
CEILING LINE WHERE
APPLICABLE
(2) LAYERS 5/8" TYPE
"X" GYP. BD. EA. SIDE
3 5/8" STEEL STUD
FRM'G @ 16" o.c.
3 1/2" ACOUSTICAL
INSULATION
FIRE SAFE SEALANT
FINISH FLOOR
BOT. OF
STRUCTURE
G5d- 2HR
FIRE SAFE SEALANT
CEILING LINE WHERE
APPLICABLE
FINISH FLOOR
BOT. OF
STRUCTURE
G5b
* ALL PENETRATIONS
THROUGH WALL TO BE
FIRE CAULKED.
5/8" TYPE "X" GYP.
BD. ONE SIDE
3 5/8" STEEL STUD
FRM'G @ 16" o.c.
3 1/2" ACOUSTICAL
INSULATION
SEALANT
IN WET LOCATIONS,
SUBSTITUTE
CEMENTITIOUS
BACKERBOARD FOR
GYP. BD.
TILE IN WET
LOCATIONS,REF
SHEET A110 & A111
DEMO
EXISTING TO REMAIN
NEW STEEL STUD
EARTH
SAND
GRANULAR FILL/DRAINAGE MATERIAL
CONCRETE (ELEVATION/SECTION)
PRECAST CONC./P.C. PLASTER/CUT STONE
GROUT
CONCRETE MASONRY UNIT
RIGID INSULATION
STEEL
WOOD FRAMING OR BLOCKING
FINISH WOOD
TILE
ROOF INSULATION
BATT INSULATION
GLASS (ELEVATION/SECTION)
GYPSUM BOARD (ELEVATION/SECTION)
PARTICLE BOARD
ACOUSTICAL CEILING PANEL OR TILE
PLYWOOD
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
TJW NPL
BUILDING SIX
SEAL:ARCHITECT/ENGINEER:
STRUCTURAL ENGINEER
BOB D. CAMPBELL
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
MEP ENGINEER
WATSON ENGINEERING
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
35% DESIGN SUBMISSION 11/21/2018
60% DESIGN SUBMISSION 1/25/2019
100% S
U B
M
IT
TA
L
90% DESIGN SUBMISSION 8/30/2019
90% DESIGN RESUBMISSION 10/23/2019
100% DESIGN SUBMISSION 12/11/2019
FIRE PROTECTION ENGINEER
CMG FIRE PROTECTION
10727 W/ 128 STREET
OVERLAND PARK, KS 66213
(913) 239-8900
100% R1 DESIGN SUBMISSION 1/24/2020
G201
INFORMATION
BEDFORD VAMC
MENTAL HEALTH
BEDFORD, MA
518-18-035
2020.01.24
ABBREVIATIONS GRAPHIC SYMBOLS PARTITION TYPES GENERAL NOTES
PARTITION DETAILS
wall legend
MATERIALS
VHABEDSanfoM Text Box
DEDUCT ALTERNATES
DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.
DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
262 SF
ELEC./STORAGE
957 SF
AREA
MAINTENANCE
SHOP
209 SF
ELE./STORAGE
71 SF
ELEC. OFFICE
325 SF
ELEC. BREAK
RM.
326 SF
MECHANICAL
282 SF
ELEVATOR
SHOP
272 SF
MCHIM
635 SF
MCHIM
1180 SF
CORRIDOR
127 SF
STAFF
RESTROOM
316 SF
LOCKER
ROOM
406 SF
MECHANICAL
SERVICE
ROOM
173 SF
MAIN
ELECTRICAL
ROOM
59 SF
VESTIBULE
374 SF
UNION OFFICE
211 SF
LOBBY
278 SF
ELEC.
85 SF
STORAGE
155 SF
OFFICE
160 SF
RESTROOM
133 SF
STAFF
RESTROOM
228 SF
STAIR
230 SF
STAIR
1464 SF
CARPENTER
SHOP
219 SF
BREAKROOM
90 SF
STORAGE
106 SF
CORRIDOR
1311 SF
TOOL ROOM
193 SF
STAIR
192 SF
STAIR
124 SF
STAIR
604 SF
CORRIDOR
835 SF
CORRIDOR
6 SF
IT
58 SF
ELEV.
75 SF
ELEV.
72 SF
MACHINE
ROOM
125 SF
STAIR
TMS
6.8"34
39" 195
4"20
39" 195
6.8"34
39" 195
6.8"34
39" 195
6.8"34
60" 300
IT
MECH
ELEVATOR &
SHAFT BY
OTHERS, NIC
GENERAL INFORMATION:
LOCATION: RESPONDING FIRE
DEPARTMENT:
AUTHORITIES HAVING
JURISDICTION:
BEDFORD VAMC MENTAL HEALTH
BUILDING 6
BEDFORD, MA
LOCAL FD HAVING JURISDICTION
DEPARTMENT OF VETERANS
AFFAIRS
PROJECT DESCRIPTION:
RENOVATION OF FIRST FLOOR FOR OUT-PATIENT MENTAL HEALTH SERVICES; NEW FINISH WORK IN LOWER LEVEL; LIMITED EXTERIOR REPAIR
INCLUDING ADDITION OF NEW ENTRY COVER ON WEST FACADE
APPLICABLE CODES
OCCUPANCY (Section 303) & STRUCTURAL CLASSIFICATION
Mixed Use Occupancy Lower Level: Business - occupancy unchanged Main Level: Business - Out-patient Mental Health Clinic Second Level: Healthcare - occupancy unchanged - In-patient Mental Health Care
BUILDING HEIGHT AND AREA:
Total Area per Floor:
Total Building Area:
13,543 sq. ft.
40,629 sq. ft.
WATER SUPPLY- FLOW TESTS:
Static:
Residual:
Flow:
Date: May 2018 Location: Hydrant #6
PASSIVE LIFE SAFETY SYSTEMS:
Corridor Ratings:
Stairwells:
Shafts:
Occupancy Separations:
Special Hazard Protection:
0 HR Required / 0 HR Provided (38.3.6.1(3)) 2 HR Required / 2 HR Provided 2 HR Required / 2 HR Provided 2 HR Required (separation from Health Care on 2nd Floor) / 2 HR Provided Automatic extinguishing system and non-rated smoke partitions - (storage rooms over 100 sq. ft. in accordance with 38.3.2.1
REGISTERED DESIGN PROFESSIONALS:
Tompkins Architects 1520 Clay St. Ste. A8 North Kansas City, MO 64116
ACTIVE LIFE SAFETY SYSTEMS:
Fire Alarm:
FACP:
Remote Annunciator Panel:
Smoke Detection:
MNS:
Exit Signs:
Egress Lighting:
Emergency Lights:
Backup Power:
Suppression- Standpipes:
Suppression- Automatic:
Fire Extinguishers:
Required/Provided per NFPA 101 & 72
Required/Provided Required/Provided Required/Provided Not Required/Provided Required/Provided Required/Provided Diesel Generator Required/Provided Not Required/ Not Provided Required/Provided per NFPA 13
Required/Provided
GENERAL BUILDING LIMITATIONS:
Construction NFPA Type II(111) (IBC Type II-A) Structural Fire Ratings Structural frame including columns, girders & trusses:
Bearing exterior walls:
Bearing interior walls:
Nonbearing exterior walls & partitions:
Nonbearing interior walls & partitions:
Floor construction including supporting beams & joists:
Roof construction including supporting beams & joists:
Shafts (connect 3 stories):
Table 601
1 HR
1 HR
1 HR
1 HR
0 HR
0 HR
0 HR
2 HR min.
Actual building area and height unchanged.
Total Building Height: 3 Stories - 43 ft.
50 psi 25 psi 517 gpm
PLUMBING FIXTURE COUNT MAIN LEVEL:
Occupancy Type
Occupant Load
Water Closet
Lavatory Drinking Fountain
Shower
B 272 6 5 3 -
Total Provided Fixtures
6 5 3 -Total Required Fixtures
9 9 3 0
All current codes, guidelines and standards according to the following:
VA Architectural Design Manual (2014) VA Mental Health Facilities Design Manual (2017) VA Fire Protection Design Manual (2015) PG 18-14 Room Finishes, Door, and Hardware Schedule (2017) PG-18-13 Barrier Free Design Standard PG-18-12 Mental Health Outpatient Services Design Guide VA Handbook H-18-8 Seismic Design Requirements Physical Security Design Manual International Building Code (2018)
Construction Type:
IBC - Type II-A (Fully Sprinklered) NFPA - Type II (111) (Fully Sprinklered) Seismic Category: C
EXISTING, NOT IN CONTRACT
2 HR RATED WALL CONSTRUCTION W/ 2
HR RATED OPENING ASSEMBLIES
FE
FIRE EXTINGUISHER
INTERIOR EXIT
EXTERIOR EXIT
OFFICE
600 SF
ROOM NAME
ROOM NUMBER
AREA IN SQUARE FEET
CODE LEGEND
ACCUMULATE EXIT WIDTH:
OCCUPANTS / EXIT WIDTH REQD
EXIT WIDTH PROVIDED / CAPACITY
198/39.6"
68"/340
NFPA Codes, Handbooks, Standards, etc. Including, but not limited to - NFPA 13 – Automatic Sprinkler Systems Handbook NFPA 20 – Stationary Fire Pumps NFPA 70 – National Electrical Code NFPA 70E – Standard for Electrical Safety in the Workplace NFPA 72 – National Fire Alarm and Signaling Code NFPA 75 – Standard for the Fire Protection of Information Technology Equipment NFPA 80 – Standard for Fire Doors and Opening Protectives NFPA 99 – Health Care Facilities NFPA 101 – Life Safety Code NFPA 110 – Standard for Emergency and Standby Power Systems NFPA 780 – Installation of Lightening Protection Systems
MEANS OF EGRESS:
Dead End Corridors shall not exceed 50 ft. - 38.2.5.2.1 Common Path of Travel shall not exceed 100 ft. - 38.2.5.3 Travel Distance shall not exceed 300 ft. - 38.2.6.2 (See Plan for actual distances)
NON PROTECTED EXIT PATH (EXEMPTION FOR FULLY
SPRINKLERED B OCCUPANCY ON LOWER LEVEL AND
MAIN LEVEL)
OCCUPANT LOAD
Lower Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants
Main Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants
Total Occupants: 272 occupants
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
TJW NPL
BUILDING SIX
SEAL:ARCHITECT/ENGINEER:
STRUCTURAL ENGINEER
BOB D. CAMPBELL
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
MEP ENGINEER
WATSON ENGINEERING
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
35% DESIGN SUBMISSION 11/21/2018
60% DESIGN SUBMISSION 1/25/2019
100% S
U B
M
IT
TA
L
90% DESIGN SUBMISSION 8/30/2019
90% DESIGN RESUBMISSION 10/23/2019
100% DESIGN SUBMISSION 12/11/2019
FIRE PROTECTION ENGINEER
CMG FIRE PROTECTION
10727 W/ 128 STREET
OVERLAND PARK, KS 66213
(913) 239-8900
100% R1 DESIGN SUBMISSION 1/24/2020
G301
CODE REVIEW - LOWER
LEVEL
BEDFORD VAMC
MENTAL HEALTH
BEDFORD, MA
518-18-035
2020.01.24
1/8" = 1'-0"1 code review plan - lower level
N O
R T
H
LIMITED SCOPE OF WORK IN LOWER LEVEL:
COSMETIC UPGRADES TO INTERIOR CORRIDOR
SYSTEM AND RENOVATIONS TO ENTRY LOBBY, TMS
ROOM AND RESTROOMS. ALL OTHER EXISTING
WALLS, DOORS AND OTHER OPENINGS REMAIN.
GENERAL NOTE:
VHABEDSanfoM Text Box
DEDUCT ALTERNATES
DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.
DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
GENERAL INFORMATION:
LOCATION: RESPONDING FIRE
DEPARTMENT:
AUTHORITIES HAVING
JURISDICTION:
BEDFORD VAMC MENTAL HEALTH
BUILDING 6
BEDFORD, MA
LOCAL FD HAVING JURISDICTION
DEPARTMENT OF VETERANS
AFFAIRS
PROJECT DESCRIPTION:
RENOVATION OF FIRST FLOOR FOR OUT-PATIENT MENTAL HEALTH SERVICES; NEW FINISH WORK IN LOWER LEVEL; LIMITED EXTERIOR REPAIR
INCLUDING ADDITION OF NEW ENTRY COVER ON WEST FACADE
APPLICABLE CODES
OCCUPANCY (Section 303) & STRUCTURAL CLASSIFICATION
Mixed Use Occupancy Lower Level: Business - occupancy unchanged Main Level: Business - Out-patient Mental Health Clinic Second Level: Healthcare - occupancy unchanged - In-patient Mental Health Care
BUILDING HEIGHT AND AREA:
Total Area per Floor:
Total Building Area:
13,543 sq. ft.
40,629 sq. ft.
WATER SUPPLY- FLOW TESTS:
Static:
Residual:
Flow:
Date: May 2018 Location: Hydrant #6
PASSIVE LIFE SAFETY SYSTEMS:
Corridor Ratings:
Stairwells:
Shafts:
Occupancy Separations:
Special Hazard Protection:
0 HR Required / 0 HR Provided (38.3.6.1(3)) 2 HR Required / 2 HR Provided 2 HR Required / 2 HR Provided 2 HR Required (separation from Health Care on 2nd Floor) / 2 HR Provided Automatic extinguishing system and non-rated smoke partitions - (storage rooms over 100 sq. ft. in accordance with 38.3.2.1
REGISTERED DESIGN PROFESSIONALS:
Tompkins Architects 1520 Clay St. Ste. A8 North Kansas City, MO 64116
ACTIVE LIFE SAFETY SYSTEMS:
Fire Alarm:
FACP:
Remote Annunciator Panel:
Smoke Detection:
MNS:
Exit Signs:
Egress Lighting:
Emergency Lights:
Backup Power:
Suppression- Standpipes:
Suppression- Automatic:
Fire Extinguishers:
Required/Provided per NFPA 101 & 72
Required/Provided Required/Provided Required/Provided Not Required/Provided Required/Provided Required/Provided Diesel Generator Required/Provided Not Required/ Not Provided Required/Provided per NFPA 13
Required/Provided
GENERAL BUILDING LIMITATIONS:
Construction NFPA Type II(111) (IBC Type II-A) Structural Fire Ratings Structural frame including columns, girders & trusses:
Bearing exterior walls:
Bearing interior walls:
Nonbearing exterior walls & partitions:
Nonbearing interior walls & partitions:
Floor construction including supporting beams & joists:
Roof construction including supporting beams & joists:
Shafts (connect 3 stories):
Table 601
1 HR
1 HR
1 HR
1 HR
0 HR
0 HR
0 HR
2 HR min.
Actual building area and height unchanged.
Total Building Height: 3 Stories - 43 ft.
50 psi 25 psi 517 gpm
PLUMBING FIXTURE COUNT MAIN LEVEL:
Occupancy Type
Occupant Load
Water Closet
Lavatory Drinking Fountain
Shower
B 272 6 5 3 -
Total Provided Fixtures
6 5 3 -Total Required Fixtures
9 9 3 0
All current codes, guidelines and standards according to the following:
VA Architectural Design Manual (2014) VA Mental Health Facilities Design Manual (2017) VA Fire Protection Design Manual (2015) PG 18-14 Room Finishes, Door, and Hardware Schedule (2017) PG-18-13 Barrier Free Design Standard PG-18-12 Mental Health Outpatient Services Design Guide VA Handbook H-18-8 Seismic Design Requirements Physical Security Design Manual International Building Code (2018)
Construction Type:
IBC - Type II-A (Fully Sprinklered) NFPA - Type II (111) (Fully Sprinklered) Seismic Category: C
EXISTING, NOT IN CONTRACT
2 HR RATED WALL CONSTRUCTION W/ 2
HR RATED OPENING ASSEMBLIES
FE
FIRE EXTINGUISHER
INTERIOR EXIT
EXTERIOR EXIT
OFFICE
600 SF
ROOM NAME
ROOM NUMBER
AREA IN SQUARE FEET
CODE LEGEND
ACCUMULATE EXIT WIDTH:
OCCUPANTS / EXIT WIDTH REQD
EXIT WIDTH PROVIDED / CAPACITY
198/39.6"
68"/340
NFPA Codes, Handbooks, Standards, etc. Including, but not limited to - NFPA 13 – Automatic Sprinkler Systems Handbook NFPA 20 – Stationary Fire Pumps NFPA 70 – National Electrical Code NFPA 70E – Standard for Electrical Safety in the Workplace NFPA 72 – National Fire Alarm and Signaling Code NFPA 75 – Standard for the Fire Protection of Information Technology Equipment NFPA 80 – Standard for Fire Doors and Opening Protectives NFPA 99 – Health Care Facilities NFPA 101 – Life Safety Code NFPA 110 – Standard for Emergency and Standby Power Systems NFPA 780 – Installation of Lightening Protection Systems
MEANS OF EGRESS:
Dead End Corridors shall not exceed 50 ft. - 38.2.5.2.1 Common Path of Travel shall not exceed 100 ft. - 38.2.5.3 Travel Distance shall not exceed 300 ft. - 38.2.6.2 (See Plan for actual distances)
NON PROTECTED EXIT PATH (EXEMPTION FOR FULLY
SPRINKLERED B OCCUPANCY ON LOWER LEVEL AND
MAIN LEVEL)
OCCUPANT LOAD
Lower Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants
Main Level: 13,543 sq. ft./100sq.ft./occupant = 136 occupants
Total Occupants: 272 occupants
129 SF
OFFICE
112 SF
OFFICE
128 SF
OFFICE
106 SF
OFFICE
113 SF
OFFICE
146 SF
TREATMENT
121 SF
EXAM
152 SF
OFFICE
112 SF
OFFICE
110 SF
OFFICE
99 SF
OFFICE
101 SF
OFFICE
111 SF
OFFICE
114 SF
OFFICE
152 SF
TREATMENT
133 SF
POLICE
OUTPOST
STATION
574 SF
LARGE
GROUP
ROOM
365 SF
GROUP
THERAPY 2
259 SF
GROUP
THERAPY 3
129349 SF
GROUP
THERAPY 1
106 SF
OFFICE
157 SF
OFFICE
164 SF
STUDENT
TRAINING
98 SF
OFFICE
149 SF
OFFICE
137 SF
OFFICE
165 SF
TREATMENT
111 SF
OFFICE
312 SF
STAFF
LOUNGE
240 SF
TEAM
272 SF
RECEPTION
117 SF
EXAM
152 SF
TREATMENT
115 SF
OFFICE
110 SF
OFFICE
102 SF
OFFICE
179 SF
OFFICE
116 SF
OFFICE
150 SF
OFFICE
114 SF
OFFICE
110 SF
OFFICE
105 SF
OFFICE
112 SF
OFFICE
114 SF
SERVER
117 SF
OFFICE
61 SF
HAC
118 SF
OFFICE
86 SF
MEDICATION
85 SF
PATIENT
STORAGE
1/
1/
EXIT
TRAVEL
DISTANCE
= 98'
EXIT
TRAVEL
DISTANCE
= 98'
EXIT ACCESS
TRAVEL DISTANCE
= 72'
EXIT ACCESS
TRAVEL
DISTANCE
= 83'
EXIT
TRAVEL
DISTANCE
= 85'
8.8"44
34" 227
9.2"46
34" 227
9.2"46
34" 227
EGRESS THROUGH
INTERVENEING SPACES -
PERMITTED BY LSC 7.5.1.6
MAXIMUM OCCUPANCY
FOR THIS ROOM WILL
BE POSTED AS 49
DAU CLEAN
37 SF
CLOSET
356 SF
WAITING
AREA
72 SF
COMPUTER
RM
20 SF
CLOSET
DAU DIRTY
STAIR TOWER BY OTHERS
FE
FE
FE
FE
FE
FE
69 SF
STAFF
RESTROOM
72 SF
RESTROOM
39 SF
RESTROOM
46 SF
STAFF
RESTROOM
53 SF
RESTROOM
221 SF
ENTRY
66 SF
RESTROOM
59 SF
RESTROOM
18 SF
ELECTRICAL
89 SF
DAU
COLLECTION
RESTROOM
78 SF
STAFF
RESTROOM
57 SF
CORRIDOR
901 SF
CORRIDOR
721 SF
CORRIDOR
705 SF
CORRIDOR
152 SF
CORRIDOR
20 SF
ELECTRICAL
125 SF
STAIR
76 SF
ELEV.
58 SF
ELEV.
IT
8.8"44
34" 227
STAIR EXIT
13.2"44
48 160
ELEVATOR &
SHAFT BY
OTHERS, NIC
FE
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
TJW NPL
BUILDING SIX
SEAL:ARCHITECT/ENGINEER:
STRUCTURAL ENGINEER
BOB D. CAMPBELL
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
MEP ENGINEER
WATSON ENGINEERING
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
35% DESIGN SUBMISSION 11/21/2018
60% DESIGN SUBMISSION 1/25/2019
100% S
U B
M
IT
TA
L
90% DESIGN SUBMISSION 8/30/2019
90% DESIGN RESUBMISSION 10/23/2019
100% DESIGN SUBMISSION 12/11/2019
FIRE PROTECTION ENGINEER
CMG FIRE PROTECTION
10727 W/ 128 STREET
OVERLAND PARK, KS 66213
(913) 239-8900
100% R1 DESIGN SUBMISSION 1/24/2020
G302
CODE REVIEW - MAIN LEVEL
BEDFORD VAMC
MENTAL HEALTH
BEDFORD, MA
518-18-035
2020.01.24
1/8" = 1'-0"1 code floor plan - main level
N O
R
VHABEDSanfoM Text Box
DEDUCT ALTERNATES
DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.
DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
A B C D E F G H I J K L M N O P Q R S T U V
7.9 7.5
6.5
3.9
E.9 H.1 Q.1J.1 L.9 N.9 R.1D.9
4.1
6.9
B.9 D.1 R.9 T.1
DOOR IN
TEMPORARY WALL
DOOR IN
TEMPORARY WALL
MAINTAIN EGRESS PATH
MAINTAIN EGRESS PATH
MAINTAIN ACCESS TO
UNION OFFICE DURING
CONSTRUCTION
ELEC./STORAGE
AREA
MAINTENANCE
SHOP
ELE./STORAGE
ELEC. OFFICE
ELEC. BREAK
RM.
ELEVATOR
SHOP
MCHIM
MCHIM
CORRIDOR
STAFF
RESTROOM
LOCKER
ROOM
MECHANICAL
SERVICE
ROOM
MAIN
ELECTRICAL
ROOM
VESTIBULE
UNION OFFICE
ELEC.
STORAGE
OFFICE
STAIR
STAIR
CARPENTER
SHOP
BREAKROOM
STORAGE
CORRIDOR
TOOL ROOM
STAIR
STAIR
STAIR
CORRIDOR
CORRIDOR
STAIR
ELEV.
STORAGE
RESTROOM
OFFICE
WHEELCHAIR STORAGE
STORAGE
MECH
TUNNEL TO
BUILDING 5
TUNNEL TO
BUILDING 7
ELECTRICAL
CLOSET
BOUNDARY OF WORK ZONE;
RETAIN EXISTING WALL
CURRENT PHASE WORK,
DEMOLITION & NEW CONSTRUCTION
NO WORK
2 HR RATED TEMPORARY WALL
1. MAINTAIN EGRESS PATHS.
2. MAINTAIN ACCESS TO UNION OFFICE 017.
3. PROVIDE SIGNAGE AS REQUIRED.
1. MAINTAIN EGRESS PATHS.
2. MAINTAIN ACCESS TO UNION OFFICE 017.
3. PROVIDE SIGNAGE PRIOR TO TUNNEL ACCESS FROM BUILDINGS 5 & 7.
A B C D E F G H I J K L M N O P Q R S T U V
7.9 7.5
6.5
3.9
E.9 H.1 Q.1J.1 L.9 N.9 R.1D.9
4.1
6.9
B.9 D.1 R.9 T.1
DOOR IN
TEMPORARY WALL
PHASE II-B
PHASE II-A
TUNNEL
TO
BUILDING
TUNNEL TO
BUILDING 7
ELEC./STORAGE
AREA
MAINTENANCE
SHOP
ELE./STORAGE
ELEC. OFFICE
ELEC. BREAK
RM.
MECHANICAL
ELEVATOR
SHOP
MCHIM
MCHIM
CORRIDOR
STAFF
RESTROOM
LOCKER
ROOM
MECHANICAL
SERVICE
ROOM
MAIN
ELECTRICAL
ROOM
VESTIBULE
UNION OFFICE
LOBBY
ELEC.
STORAGE
OFFICE
STAFF
RESTROOM
STAIR
014STAIR
CARPENTER
SHOP
BREAKROOM
STORAGE
CORRIDOR
TOOL ROOM
STAIR
STAIR
STAIR
CORRIDOR
CORRIDOR
STAIR
ELEV.
TMS
MECH
ELECTRICAL
DOOR IN
TEMPORARY WALL
DOOR IN
TEMPORARY WALL
IT
IT
ELEV.
MACHINE
ROOM
RESTROOM
1. MAIN LEVEL & SECOND LEVEL (N.I.C.) TO BE COMPLETED IN
SINGLE PHASE. AREAS WILL BE UNOCCUPIED DURING ENTIRETY OF
CONSTRUCTION.
2. LOWER LEVEL TO BE PARTIALLY OCCUPIED BY BOTH STAFF AND
PATIENTS.
3. MAINTAIN 2 HOUR FIRE SEPARATION BETWEEN CONSTRUCTION
AND OCCUPIED SPACES AT ALL TIMES. ALL TEMPORARY WALLS
TO BE 2 HR CONSTRUCTION AND EXTEND TO TOP OF DECK. ALL
EXISTING HVAC, PLUMBING, ELECTRICAL OR OTHER TO BE
COORIDNATED TO MAINTAIN FIRE RATING.
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
TJW NPL
BUILDING SIX
SEAL:ARCHITECT/ENGINEER:
STRUCTURAL ENGINEER
BOB D. CAMPBELL
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
MEP ENGINEER
WATSON ENGINEERING
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
35% DESIGN SUBMISSION 11/21/2018
60% DESIGN SUBMISSION 1/25/2019
100% S
U B
M
IT
TA
L
90% DESIGN SUBMISSION 8/30/2019
90% DESIGN RESUBMISSION 10/23/2019
100% DESIGN SUBMISSION 12/11/2019
FIRE PROTECTION ENGINEER
CMG FIRE PROTECTION
10727 W/ 128 STREET
OVERLAND PARK, KS 66213
(913) 239-8900
100% R1 DESIGN SUBMISSION 1/24/2020
G401
PHASING PLANS
BEDFORD VAMC
MENTAL HEALTH
BEDFORD, MA
518-18-035
2020.01.24
3/32" = 1'-0"1 phasing plan - lower level - phase I
PHASING PLAN LEGEND
phase I general notes phase II-A & II-B general notes
3/32" = 1'-0"2 phasing plan - lower level - phase II phasing general notes
VHABEDSanfoM Text Box
DEDUCT ALTERNATES
DEDUCT ALTERNATE NUMBER 1 - Delete all elevator work pertaining to specification section 14 24 00 Hydraulic Elevator. Elevator shaft to remain in project. Add to frame elevator shaft opening on the basement, first floor, and second floor with a two hour fire rated shaft wall system with 5/8” gypsum wallboard to face of shaft wall on the elevator lobby side of the opening; ensure face of gypsum board aligns with adjacent gypsum board; paint gypsum wallboard.
DEDUCT ALTERNATE NUMBER 2: Delete all roof repair work in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
DEDUCT ALTERNATE NUMBER 3: Delete all bathroom basement work and filling of abandoned steam trenches in Project 2 (FCA Out Patient Mental Health Renovation Building 6 First Floor, VA Medical Center, Bedford, Massachusetts 518-18-035).
GENERAL NOTES - STRUCTURAL
1. General Information
A. The contractor shall verify dimensions and conditions before construction and notify the engineer of any discrepancies, inconsistencies, or difficulties affecting the work before proceeding.
B. The contractor shall coordinate all disciplines, verifying size and location of all openings, whether shown on structural drawings or not, as called for on architectural, mechanical, or electrical drawings. In the case of work in an existing building the contractor shall scan existing structure to locate all rebar in the area of the new core/opening using ground penetrating radar and notify the engineer of record for review prior to coring/cutting. Conflicts, inconsistencies, or other difficulties affecting structural work shall be called to the architect or engineer's attention for direction before proceeding.
C. All design and construction work for this project shall conform to the requirements of the following governing design codes:
1.) International Building Code (IBC 2012) as amended by the city of Bedford. MA 2.) Minimum Design Loads for Buildings and Other Structures (ASCE7-10) 3.) Specification for Structural Steel Buildings (AISC 360-10)
Member Design Basis is Allowable Stress Design (ASD) Connection Design Basis is Allowable Stress Design (ASD)
4.) Structural Welding Code (AWS D1.3-98) 5.) Building Code Requirements for Structural Concrete (ACI 318-11) 6.) Building Code Requirements for Masonry Structures (ACI 530-11/TMS 402-11) 7.) North American Specification for the Design of Cold-Formed Steel Structural
Members (AISI S100-07/S1-1) 8.) National Design Specification (NDS) for Wood Constriction with 2012
Supplements (ANSI/AWC NDS-2012) 9.) Special Design Provisions for Wind and Seismic (AWC SDPWS-2008)
D. These drawings are for this specific project and no other use is authorized.
2. Structural Load Design Criteria
A. Stair Live = 100psf B. Roof Live = 20psf; Roof Collateral Dead = 10psf C. Snow: Pg = 50psf, Pf =35psf, Is = 1.0, Ce = 1.0, Ct = 1.0, Drift per ASCE/SEI 7 D. Lateral Loads:
1.) Wind: V = 136 mph, Exposure B Occupancy [Risk] Category II, Iw=1.0 GCpi=+/-0.18 Design wind pressures to be used for the design of exterior component and cladding materials on the designated zones of wall and roof surfaces shall be per section 30.7 and Table 30.7-2 of ASCE/SEI 7. Tabulated pressures shall be multiplied by effective area reduction factors, exposure adjustment factors, and topographic factors where applicable
2.) Seismic: Ss = 0.223, S1 = 0.071 Occupancy [Risk] Category II, Ie=1.0, Site Classification D; Sds = 0.238; Sd1 = 0.114 Seismic Design Category B Basic Seismic Force-resisting System:
E. This project is designed to resist the most critical effects resulting from the load combinations of section 1605.3 of the International Building Code.
3. Concrete
A. All concrete for foundations (walls, grade beams, footings and piers) shall develop minimum ultimate compressive design strength of 3500 psi in 28 days, but not less than 500 pounds of cement shall be used per cubic yard of concrete regardless of strengths obtained, not over 6 gallons of water per 100 pounds of cement and not over 4 inches of slump.
B. All concrete for interior flatwork shall develop minimum ultimate compressive design strength of 4000 psi in 28 days, but not less than 540 pounds of cement shall be used per cubic yard of concrete regardless of strengths obtained, not over 5.40 gallons of water per 100 pounds of cement and not over 4 inches of slump. Concrete mix shop drawing shall contain testing data proving concrete design mix shrinkage is less than 0.034% at 28 days when tested according to ASTM C157 (air drying method only).
C. All concrete for exterior flatwork shall have a minimum design compressive strength of 4500 psi in 28 days, with not less than 560 pounds of cement per cubic yard of concrete, not over 5 gallons of water per 100 pounds of cement, with 6% +/- 1% air entrainment, and a maximum of 4 inches of slump.
D. The preceding minimum mix requirements may have water-reducing admixtures conforming to ASTM C494 added to the mix at manufacturer's dosage rates for improved workability.
E. The preceding minimum mix requirements may have up to 15% maximum of the cement content replaced with an approved ASTM C618 Class C fly ash, provided the total minimum cementitious content is not reduced.
F. Combined aggregate (coarse plus fine) for all concrete shall be well graded from coarsest to finest with no more than 18 percent and not less than 8 percent retained on an individual sieve, except that less than 8 percent may be retained on coarsest sieve and on No. 50 and finer sieves. Submit this gradation report with the concrete mix design shop drawings.
G. All interior concrete slabs on grade shall be placed over 15 mil, Class A Vapor Barrier per ASTM E1745 with less than 0.01 perms, tested after mandatory conditioning. All joints shall be lapped and sealed per manufacturer's recommendations. All penetrations, as well as damaged vapor barrier material shall also be sealed per manufacturer's recommendation prior to concrete placement. Install barrier per manufacturer recommended details at all discontinuous edges (at interior columns, exterior edge of slab, etc.) to ensure terms of warranty are followed. The vapor barrier shall be placed over free-draining granular material as prescribed by the project soils report.
H. All concrete is reinforced concrete unless specifically called out as unreinforced.
Reinforce all concrete not otherwise shown with same steel as in similar sections or areas. Any details not shown shall be detailed per ACI 315 and meet requirements of ACI 318, current editions.
I. Control joints in dirt formed slab to be as shown on plans. Where not shown, limit controlled areas to not more than 144 square feet, or 12 feet on any side.
Slab panel side ratio shall not exceed 1 1/2 to 1.
J. Contractor shall verify that all concrete inserts, reinforcing and embedded items are correctly located and rigidly secured prior to concrete placement.
K. Construction joints in beams, slabs, and grade beams shall occur at midspan (middle third) unless noted otherwise. Provide 2 x 4 horizontal keys at construction joints for shear transfer.
L. No aluminum items shall be embedded in any concrete.
4. Reinforcing Steel
A. All reinforcing steel shall conform to the requirements of ASTM A615 or A706 grade 60 steel. Welded plain wire fabric shall be supplied in sheets and conform to the requirements of ASTM A185.
B. Clear minimum coverage of concrete over reinforcing steel shall be as follows:
1.) Concrete placed against earth: 3" 2.) Formed concrete against earth: 2" 3.) Slabs: 1" 4.) Beams or Columns: 1-1/2" 5.) Other 2" All coverage shall be nominal bar diameter minimum.
C. All dowels shall be the same size and spacing as adjoining main bars (splice lap 48 bar diameters or 24" minimum unless noted otherwise).
D. At corners of all walls, beams, and grade beams supply corner bars (minimum 2'-0" in each direction or 48 bar diameters) in outside face of wall, matching size and spacing of horizontal bars.