Phase_1_Rockefeller_Campus_Garage_Permit-Bid_Drawings.pdf
PDF 21 MB Posted
- Attached to
- Rockefeller Greenhouse Campus CM-R Improvements
- Solicitation number
- AR2547
- Issued by
- Cuyahoga County, Ohio
About this file
This document is a permit and bid drawing set for the Rockefeller Greenhouse Campus Garage Building renovation project undertaken by the City of Cleveland Department of Public Works, Mayor's Office of Capital Projects, in collaboration with IKM Architecture and consulting engineers Osborn Engineering and Algebra AEC. The project encompasses alterations to an existing garage building located at 750 E 88th Street, Cleveland, Ohio 44108, with a planned permit and bid set date of January 6, 2026. The scope of work includes structural concrete and masonry repairs, replacement of deteriorated steel lintels, installation of new roofing systems with insulation and TPO membrane, new mechanical systems including four condensing unit heaters and one split-system air conditioner, plumbing improvements including new roof drains and connections, electrical upgrades with new lighting fixtures and power distribution, and fire alarm system enhancements. The garage building is classified as a utility and miscellaneous occupancy (Type III-B construction) with a calculated occupant load of 14 persons, containing approximately 2,288 square feet on the first floor divided into existing garage bays, storage areas, and an electrical closet. The project includes demolition of existing non-compliant elements, detailed architectural specifications for masonry repointing and brick replacement, roofing details with coping and scupper installations, and new mechanical controls integrated with building automation systems.
The construction documents establish comprehensive design criteria and technical specifications governed by the 2017 Ohio Building Code (International Building Code 2015 with amendments), ASCE 7-10 loading standards, and applicable mechanical, plumbing, and electrical codes. The project requires special inspection for concrete work, masonry construction at two levels, and fire alarm system installation, with detailed coordination requirements among mechanical, electrical, plumbing, and structural trades. The structural and mechanical work involves specific material requirements including 4,000 PSI concrete for interior work, ASTM C90 concrete masonry units with 2,500 PSI grout, and natural gas service extensions to connected buildings. Cost contingencies include a 2-ton allowance for reinforcing bars and provisions for lean concrete under foundations due to potential soil conditions, with the contractor responsible for reimbursing unused allowances. The documents emphasize field verification of existing conditions, noting that original construction documentation from April 1938 is the basis for existing condition assumptions, and establish the contractor's responsibility for all means, methods, shoring design, and coordination among trades, with all associated costs included in the base bid.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5 4 3 2 1
D
C
B
A
B.1
C.1
D.1
A.1
OCCUPANCY CLASSIFICATIONS CHAPTER 3 U, UTILITY AND MISCELLANEOUS - GARAGE (UNCHANGED)
ALLOWABLE HEIGHT, STORIES CHAPTER 5 EXISTING CONSTRUCTION (SECTION 504, UNCHANGED)
ALLOWABLE AREA CHAPTER 5 EXISTING CONSTRUCTION (SECTION 506, UNCHANGED)
TYPE OF CONSTRUCTION CHAPTER 6 III-B, EXISTING CONSTRUCTION (UNCHANGED)
FIRE PROETECTION CHAPTER 9 WITHOUT SPRINKLER SYSTEM (UNCHANGED)
OCCUPANT LOAD CHAPTER 10 SECTION 1004
OCCUPANCIES TABLE 1004.1.2
ACCESSORY STORAGE 300 SF GROSS/OCCUPANT FIRST FLOOR 2,288 SF/ 300 = 8 OCCUPANTS
TOTAL CALCULATED OCCUPANT LOAD = 8 OCCUPANTS
TOTAL ACTUAL OCCUPANT LOAD = 0 OCCUPANTS
NUMBER OF EXITS CHAPTER 10 2 EXITS, EXISTING CONSTRUCTION (TABLE 1006.3.1, UNCHANGED)
MAXIMIUM COMMON PATH OF EGRESS CHAPTER 10 100FT (OCC. LOAD < 30) - WITHOUT SPRINKLER SYSTEM (TABLE 1006.2.1)
TRAVEL DISTANCE
EXIT ACCESS TRAVEL DISTANCE CHAPTER 10 300FT - WITHOUT SPRINKLER SYSTEM (TABLE 1017.2)
ELECTRICAL
P E
R M
IT
/B
ID
S
E T
S H
E E
T N
U M
B E
R
SHEET NAME
● GE001 GENERAL ELECTRICAL, TECHNOLOGY, FIRE ALARM
● E101 FIRST FLOOR POWER DEMO AND NEW PLANS
● E201 FIRST FLOOR LIGHTING DEMO AND NEW PLANS
● E501 ELECTRICAL DETAILS
● E601 ELECTRICAL SCHEDULES AND DIAGRAMS
STRUCTURAL
P E
R M
IT
/B
ID
S
E T
S H
E E
T N
U M
B E
R
SHEET NAME
● S001G GENERAL NOTES
● S002G GENERAL NOTES
● S101G GARAGE REPAIR PLAN
● S201G GARAGE REPAIR ELEVATIONS
● S202G GARAGE REPAIR ELEVATIONS
● S301G TYPICAL CONCRETE REPAIR DETAILS AND NOTES
● S302G TYPICAL MASONRY REPAIR DETAILS
● S303G TYPICAL CONCRETE REPAIR DETAILS
● S304G TYPICAL REPAIR DETAILS
MECHANICAL
P E
R M
IT
/B
ID
S
E T
S H
E E
T N
U M
B E
R
SHEET NAME
● GM001 GENERAL MECHANICAL
● M100 UNDERGROUND MECHANICAL
● M101 FIRST FLOOR MECHANICAL DEMO AND NEW PLANS
● M102 ROOF MECHANICAL
● M501 MECHANICAL DETAILS
● M801 MECHANICAL CONTROLS
PLUMBING
P E
R M
IT
/B
ID
S
E T
S H
E E
T N
U M
B E
R
SHEET NAME
● GP001 GENERAL PLUMBING
● PD101 PLUMBING DEMO PLANS
● P102 PLUMBING PLANS
NORTH
C
IT
Y O
F C
LE
V E
LA
N D
SHEET NO:
CHECKED BY:
DESIGNED BY:
SCALE:
DELINEATED BY:
PROJECT NAME:
D E
P A
R T M
E N
T O
F P
U B
L
IC
W O
R K
S
C it y o f C le ve la n d
M a yo r' s O ff ic e o f C a p it a l P ro je c ts
D iv is io n o f A rc h it e c tu re
C le ve la n d
C it y H a ll
L a k e si d e A ve n u e
R o o m
A C le ve la n d O
H
-1
P h o n e
-2
F a x:
-4 a n d S it e
D e ve lo p m e n t
TITLE:
h u ro n r o a d e a s t s u it e c le v e la n d o h
THE CITY OF CLEVELAND
Rockefeller Greenhouse Campus Renovation
750 E 88TH STREET
CLEVELAND, OHIO 44108
DEPARTMENT OF PUBLIC WORKS
MAY0R'S OFFICE OF CAPITAL PROJECTS
JUSTIN M. BIBB, MAYOR
CITY OF CLEVELAND
BLAINE A. GRIFFIN, COUNCIL PRESIDENT
CLEVELAND CITY COUNCIL
ANTHONY T HAIRSTON, COUNCIL MEMBER
CLEVELAND CITY COUNCIL
FRANK D. WILLIAMS, DIRECTOR
DEPARTMENT OF PUBLIC WORKS
ARCHITECT:
Division of Architecture and Site Development
Telephone: (216) 664-2374
Email: jmestnik@Clevelandohio.gov
Contact Person: Joe Mestnik, RA
ARCHITECT:
IKM Architecture
Knight & Stolar (landscape)
Finley Consulting Group (exterior envelope)
Mongomery Smith (greenhouse)
Telephone: (878) 999-2284
Email: ayaracs@ikminc.com
Contact Person: Adam Yaracs, AIA
BUILDING DEPARTMENT:
Chief Building Official, Thomas Vanover
Telephone: (216) 664-2282
Email: TVonover@Clevelandohio.gov
Contact Person: TBD
FIRE MARSHALL:
Captain David Telban
Telephone: (216) 664-6867
Email: Dtelban@Clevelandohio.gov
Call to schedule inspections
MECHANICAL, ELECTRICAL
AND PLUMBING ENGINEER:
Algebra AEC
Telephone: (248) 227-5542
Email: Shariq@algebraaec.com
Contact Person: Shariq Ali
STRUCTURAL AND CIVIL ENGINEER:
Osborn Engineering
Telephone: (216) 861-2020
Email: jpollner@osborn-eng.com dwatkins@osborn-eng.com
Contact Person: John Pollner (Structure)
David Watkins (Civil)
SHEET INDEX
BUILDING PLAN
LOCATION MAP
BUILDING CODE SUMMARY
JAMES D. DEROSA, DIRECTOR
MAYOR'S OFFICE OF CAPITAL PROJECTS
N/A
IKM, Inc
GARAGE BUILDING
/6
/2
:3
:4
P
M A u to d e s k D o c s /2
-0
C it y o f C le v e la n d R o c k e fe lle r
G re e n h o u s e R
/2
-0
C it y o f C le v e la n d
R o c k e fe lle r G re e n h o u s e G a ra g e
R
.r v t
A0
GARAGE COVER SHEET
Adam Yaracs
Ty Juan Swanson-Sawyer
-0
R o c k e fe ll e r
P a rk G re e n h o u s e
C a m p u s
G a ra g e B u il d in g E th
S t, C le v e la n d
O H
ARCHITECTURAL - GARAGE
P E
R M
IT
/B
ID
S
E T
S H
E E
T N
U M
B E
R
SHEET NAME
● A100 FIRST FLOOR AND ROOF DEMOLITION PLANS
● A200 FIRST FLOOR AND ROOF PLANS
● A400 EXTERIOR ELEVATIONS
● A401 BUILDING SECTIONS AND INTERIOR ELEVATION
● A500 EXTERIOR AND MISC. DETAILS
● A501 ROOF DETAILS
● A502 CANOPY DETAIL
● R001 FOR REFERENCE ONLY - EXISTING FLOOR PLANS AND
ELEVATIONS
● R002 FOR REFERENCE ONLY - EXISTING DETAILS
NORTH
GENERAL
P E
R M
IT
/B
ID
S
E T
S H
E E
T N
U M
B E
R
SHEET NAME
● A0 GARAGE COVER SHEET
● AL100 LIFE SAFETY PLAN
● LS100 LANDSCAPING PLAN
● A000 GENERAL INFORMATION
MARK DATE DESCRIPTION
01.05.2026 PERMIT/BID SET
A300
SIM
DETAIL NUMBER
DRAWING NUMBER
DETAIL/ENLARGED PLAN SYMBOL
DETAIL NUMBER
DRAWING NUMBER
WALL SECTION
DETAIL NUMBER
DRAWING NUMBER
EXTERIOR ELEVATION SYMBOL
DETAIL NUMBER
DRAWING NUMBER
INTERIOR ELEVATION SYMBOL
A600 2
DETAIL NUMBER
DRAWING NUMBER
BUILDING SECTION
INDICATED DETAIL MAY, OR MAY
NOT BE EXACTLY THE SAME - TYP
GENERAL SYMBOLS
WINDOW TYPE,
CURTAINWALL/
STOREFRONT GLAZING
TYPE
ROOF DRAIN
FLOOR DRAIN
REVISION
SYMBOL
COLUMN
GRID
VIEW REFERENCE SYMBOL
DETAIL NUMBER
DRAWING NUMBER
OVERHEAD CONSTRUCTION
ROOM NUMBER
XXX CODED// ARCHITECTURAL//
CONSTRUCTION NOTES
A200 2
MATCH
LINE
ADD LETTER SUFFIX WHEN MORE
THAN ONE DOOR, 500A, 500B ETC.500A
DRAWING SYMBOLS
1/A100
P2A PARTITION
TYPE
1i
A100
A100
ROOM NAME
CONCRETE
MASONRY
CONCRETE FILL, SAND,
GROUT, DRYWALL
CARPET
CERAMIC TILE
ACOUSTICAL TILE
(LARGE SCALE)
WOOD - FINISH
(SECTION OR ELEVATION)
WOOD - ROUGH
(SECTION)
INSULATION - RIGID
INSULATION - BATT OR LOOSE
STEEL
GRANITE
MATERIALS LEGEND
ABBREVIATIONS
ABV.
A.F.F.
A.P.
A.C.P.
A.C.T.
A.W.C.
A.W.P.
ADD'L
ADJ.
ADJT.
A.C.
A.H.U.
ALT.
ALUM.
AMT.
A.B.
ANOD.
APPL
APP'D
APPROX.
ARCH.
A/E
A.V.
AUX.
AVG.
ABOVE
AT
ABOVE FINISHED FLOOR
ACCESS PANEL
ACOUSTICAL CEILING PANEL
ACOUSTICAL CEILING TILE
ACOUSTICAL WALL COVERING
ACOUSTIC WALL PANEL
ADDITIONAL
ADJUSTABLE
ADJACENT
AIR CONDITIONING
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
AMOUNT
ANCHOR BOLT(S)
ANODIZED
APPLICATION
APPROVED
APPROXIMATE(LY)
ARCHITECT(URAL)
ARCHITECT/ENGINEER
AUDIO/VISUAL CONTRACT(OR)
AUXILIARY
AVERAGE
B. CAB.
B. PL.
BSMT.
BAT. IN.
BM.
BRG.
BRG. PL.
BMK.
BT.
BTWN.
BITUM.
B.L.
BLK.
BLKG.
BD.
BTM.
BTU
BRZ.
B.U.
B.U.R.
BULL. BD.
B.R.
BASE CABINET
BASE PLATE
BASEMENT
BATT INSULATION
BEAM
BEARING
BEARING PLATE
BENCHMARK
BENT
BETWEEN
BITUMINOUS
BORROWED LIGHT
BLOCK
BLOCKING
BOARD
BOTTOM
BRITISH THERMAL UNIT
BRONZE
BUILT UP
BUILT UP ROOFING
BULLETIN BOARD
BUMPER RAIL
C.U.H.
CAB.
C.R.
CPT.
C.I.P
C.I.
CL.
CLG.
CEM.
CTR.
C/C
C.T.
CHBD
CHAM.
CIR.
CIRCUM.
CLR.
C.O.
COEF.
C.W.
COL.
C.F.M.F.
C.S.
CONC.
C.M.U.
COND.
CONSTR.
CONT.
CONTR.
C.J.
C.G.
CORRG.
C.M.P.
CTSK.
CRSE.
C.R.
C.F.M.
CU. FT.
CU. YD.
C.C.
C.C.T.
CABINET UNIT HEATER
CABINET
CARD READER
CARPET
CAST IN PLACE
CAST IRON
CENTERLINE
CEILING
CEMENT
CENTER
CENTER TO CENTER
CERAMIC TILE (CFT, CWT, CTB)
CHALKBOARD
CHAMFER
CIRCLE
CIRCUMFERENCE
CLEAR(ANCE)
CLEAN OUT OR CASED OPENING
COEFFICIENT
COLD WATER
COLUMN
COLD FORMED METAL FRAMING
COMPOSITE STONE
CONCRETE
CONCRETE MASONRY UNIT
CONDENSATE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CONSTRUCTION JOINT
CORNER GUARD
CORRUGATED
CORRUGATED METAL PIPE
COUNTERSUNK
COURSE(S)
CRASH RAIL
CUBIC FEET PER MINUTE
CUBIC FOOT
CUBIC YARD
CUBICAL CURTAIN
CUBICAL CURTAIN TRACK
DMPR.
D.L.
DK.
DP.
DEFL.
DEG.
DTL.
DSMG.
DEMO.
DMNT.
DIAM.
DIAPH.
DIFF.
DIM.
DISP.
DR.
DWL.(S)
DN.
D.S.
DWR.
DWG.
D.F.
DAMPER
DEAD LOAD
DECK
DEEP
DEFLECTION
DEGREE
DETAIL
DEMISING
DEMOLITION
DEMOUNTABLE
DIAMETER
DIAPHRAGM
DIFFUSER
DIMENSION
DISPLAY
DOOR
DOWEL(S)
DOWN
DOWNSPOUT
DRAWER
DRAWING
DRINKING FOUNTAIN
EA.
E.F.
E.S.
E.W.
ELEC.
E.W.C.
E.C.
E.W.C.
ELEV.
EMB.
EMERG.
ENAM.
ENG.
ENCL.
E.P.D.M.
EQ.
EXH.
EXIST.
EXP.
E.J.
EXP'D
EXT.
E.F.S.
E.I.F.S.
EW./ES
EACH
EACH FACE
EACH SIDE
EACH WAY
EAST
ELECTRIC(AL)
ELECTRICAL CONTRACTOR
ELECTRONIC WATER COOLER
ELEVATION
EMBEDMENT
EMERGENCY
ENAMEL
ENGINEER
ENCLOSE(URE)
ETHYL PROPYLENE DIENE MONOMER
EQUAL
EXHAUST
EXISTING
EXPANSION
EXPANSION JOINT
EXPOSED
EXTERIOR
EXTERIOR FINISH SYSTEM
EXTERIOR INSULATION FINISH SYSTEM
EYEWASH/EMERGENCY SHOWER
F.O.C.
F.O.F.
F.O.M.
F.O.S.
FFIN.
FT.
FBD.
F.F.
FIN.
FIN. FL.
F.D.C.
F.E.
F.E.C.
F.D.V.
FIXT.
F.R.
FLR.
F.D.
F/F
F.S.E.
F.S.E.C.
FTG.
FDN.
F.H.
F.B.O.
FACE OF CONCRETE
FACE OF FINISH
FACE OF MASONRY
FACE OF STUD
FACTORY FINISH
FOOT (FEET)
FIBERBOARD
FILTER FABRIC
FINISH(ED)
FINISH FLOOR
FIRE DEPARTMENT CONNECTION
FIRE EXTINGUISHER
FIRE EXTINGUISHING CABINET
FIRE DEPARTMENT VALVE
FIXTURE
FIRE RATED
FLOOR
FLOOR DRAIN
FLOOR TO FLOOR
FOOD SERVICE EQUIPMENT
FOOD SERVICE EQUIPMENT CONTRACTOR
FOOTING
FOUNDATION
FUME HOOD
FURNISHED BY OTHERS
GA.
G.B.
G.B.C.
G.L.B.
G.P.M.
GALV.
G.C.
GL.
G.T.
GR.
GRB.
GROM
G.S.F.
G.F.
GYP.
G.W.B.
GAUGE
GRAB BAR
GRANULAR BASE COURSE
GLUE LAMINATED BEAM
GALLONS PER MINUTE
GALVANIZED
GENERAL CONTRACT(OR)
GLASS OR GLAZING
GLASS TILE
GRADE
GRADE BEAM
GROMMET
GROSS SQUARE FEET
GROUND FACE
GYPSUM
GYPSUM WALL BOARD
HCP.
H.R.
HDBD.
HDW.
HD.
HDR.
HTG.
H.V.A.C.
HGT.
H.
H.S.
H.S.B.
H.W.H.
HK.
H.C.
H.M.
HR.
HORIZ.
H.P.
H.B.
H.W.
HYD.
HANDICAPPED
HANDRAIL
HARDBOARD
HARDWARE
HEAD
HEADER
HEATING
HEATING, VENTILATION, & AIR CONDITIONING
HEIGHT
HIGH
HIGH STRENGTH
HIGH STRENGTH BOLT
HOT WATER HEATER
HOOK
HOLLOW CORE
HOLLOW METAL
HOUR
HORIZONTAL
HORSE POWER
HOSE BIBB
HOT WATER
HYDRANT
IN.
INSP.
INSUL.
I.T.W.P.S.
INT.
I.D.
I.F.
ILLUM.
INV.
INCH
INSPECT
INSULATION
INSULATING TRANSLUCENT WALL PANEL SYSTEM
INTERIOR
INTERIOR DIAMETER
INTERIOR FACE
ILLUMINATED
INVERT
JAN.
JT.
JST.
JBOX
JANITOR
JOINT
JOIST
JUNCTION BOX
KVA
KW
K
KLF
KSF
KIT.
K.O.
KILOVOLT-AMP
KILOWATT
KIP
KIPS PRE LINEAR FOOT
KIPS PER SQUARE FOOT
KITCHEN
KNOCK OUT
LAB.
LAM.
L.V.L.
L.C.
LAT.
LAV.
L.H.
LTG.
LT. WT.
LNTL
L.L.
L.L.H.
L.L.V.
LVR.
L.V.T.
L.V.P.
LABORATORY
LAMINATED
LAMINATED VENEER LUMBER
LANDSCAPING CONTRATOR
LATERAL
LAVATORY
LEFT HAND
LIGHTING
LIGHT WEIGHT
LINTEL
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LOUVER
LUXURY VINYL TILE
LUXURY VINYL PLANK
MACH.
MARK.
M.H.
MFG.
M.BD.
MAS.
M.O.
MATL.
MAX.
MECH.
MED.
MDF
M.D.O.
MET.
M.P.H.
MIN.
MIR.
MISC.
M.B.
MOD.
MLDG.
MON.
M.R.
M.R.G.W.B.
M.T.
MTD.
MACHINE
MARKER
MANHOLE
MANUFACTURE(ER)
MARKER BOARD
MASONRY
MASONRY OPENING
MATERIAL
MAXIMUM
MECHANICAL
MEDIUM
MEDIUM DENSITY FIBERBOARD
MEDIUM DENSITY OVERLAY
METAL
MILES PER HOUR
MINIMUM
MIRROR
MISCELLANEOUS
MODIFIED BITUMINOUS (ROOFING)
MODULAR
MOLDING
MONUMENT
MOISTURE RESISTANT
MOISTURE RESISTANT GYPSUM WALL BOARD
MOSAIC TILE
MOUNTED
NAT.
N.S.F.
NRC
NOM.
N.S.M.F.
N.
N.I.C.
N.R.P.
N.T.S.
NO.
O.C.
OPG.
OPP.
OPP. HD.
OZ.
O.A.
O.D.
O/O
O.H.
OFCI
OFOI
OFVI
PR.
P.T.D.
P.T.R.
PAR.
P.BD.
PVMT.
PERIM.
P. LAM.
PLAS.
PL.
PLBG.
PLYWD.
PT.
PT.
P.V.C.
LB.
P.C.F.
P.L.F.
P.S.F.
P.S.I.
PREFAB.
PREFIN.
P.R.V.
P. LN.
PROJ.
PAIR
PAPER TOWEL DISPENSER
PAPER TOWEL RECEPTOR
PARALLEL
PARTICLE BOARD
PAVMENT
PERIMETER
PLASTIC LAMINATE
PLASTER
PLATE
PLUMBING
PLYWOOD
POINT
PAINT
POLYVINYL CHLORIDE
POUND
POUNDS PER CUBIC FOOT
POUNDS PER LINEAR FOOT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PREFABRICATED
PRE-FINISHED
PRESSURE REDUCING VALVE
PROPERTY LINE
PROJECTION
RECP.
R.
RAD.
R.W.C.
REF.
REFR.
REINF.
RFC
REQD.
REQTS
R.A.
R.A.G.
REV.
R.O.W.
R.D.
RFG.
RTU
RM.
R.O.
R.S.
SAN.
S.N.D.
S.N.R.
SECT.
S.R.W.C.
S.R.D.
SEP.
SHT.
SHTG.
SHWR.
S.P.R.
SIM.
S.O.G.
SPD
S.C.
S.S.M.
S.A.B.
S.T.C.
S.
SPA.
SPECS.
SPF.
S.F.R.M.
S.C.
SQ.
S.F.
S.Y.
ST. STL.
STD.
STL.
STOR.
ST. D.
STRL.
S.G.T.
SUB.
SUP.
S.A.
SURF.
S.M.
SUSP.
SW.
SYM.
SYS.
SANITARY
SANITARY NAPKIN DISPENSER
SANITARY NAPKIN RECEPTACLE
SECTION
SECONDARY RAIN WATER CONDUCTOR
SECONDARY ROOF DRAIN
SEPARATE
SHEET
SHEATHING
SHOWER
SINGLE - PLY ROOFING
SIMILAR
SLAB ON GRADE
SOAP DISPENSER
SOLID CORE
SOLID SURFACE MATERIAL
SOUND ATTENUATION BLANKET
SOUND TRANSMISSION CLASS
SOUTH
SPACE
SPECIFICATIONS
SPLIT FACE
SPRAYED FIRE RESISTANT MATERIAL
SPRINKLER CONTRACT(OR)
SQUARE
SQUARE FEET
SQUARE YARD
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STORM DRAIN
STRUCTURAL
STRUCTURAL GLAZED TILE
SUBSTITUTE
SUPPLY
SUPPLY AIR
SURFACE
SURFACE MOUNTED
SUSPENDED
SWITCH
SYMMETRICAL
SYSTEM
RECEPTACLE
RADIUS
RADIATOR
RAIN WATER CONDUCTOR
REFERENCE
REFRIGERATOR
REINFORCING
REINFORCED CONCRETE
REQUIRED
REQUIREMENTS
RETURN AIR
RETURN AIR GRILLE
REVISED (REVISION)
RIGHT OF WAY
ROOF DRAIN
ROOFING
ROOF TOP UNIT
ROOM
ROUGH OPENING
ROUGH SAWN
TBD
T.CAB
T.I.
T.C.
TELCOM
TEL.
T.V.
TEMP.
TEMP. GL.
T.P.O.
THERMO.
THK.
THR.
THSLD.
TLT.
T.P.D.
T.&G .
T.& B.
T/
T/BM.
T/CURB
T/FTG.
T/JST
T/SLAB
T/LIN.
T/ROOF
T/STL.
T/WALL
T. BAR
T.R.
TYP.
TACK BOARD
TALL CABINET
TAPERED INSULATION
TELECOMMUNICATIONS CONTRACT(OR)
TELECOMMUNICATIONS
TELEPHONE
TELEVISION
TEMPERATURE
TEMPERED GLASS
THERMOPLASTIC POLYOLEFIN (ROOFING)
THERMOSTAT
THICKNESS
THREAD
THRESHOLD
TOILET
TOILET PAPER DISPENSER
TONGUE & GROOVE
TOP & BOTTOM
TOP OF
TOP OF BEAM
TOP OF CURB
TOP OF FOOTING
TOP OF JOIST
TOP OF SLAB
TOP OF LINTEL
TOP OF ROOF
TOP OF STEEL
TOP OF WALL
TOWEL BAR
TRASH RECEPTACLE
TYPICAL
NATURAL
NET SQUARE FEET
NOISE REDUCTION COEFFICIENT
NOMINAL
NON-STRUCTURAL METAL FRAMING
NORTH
NOT IN CONTRACT
NON-REMOVABLE PINS
NOT TO SCALE
NUMBER
ON CENTER
OPENING
OPPOSITE
OPPOSITE HAND
OUNCE
OUTSIDE AIR
OUTSIDE DIAMETER
OUT TO OUT
OVERHEAD
OWNER FURNISHED CONTRACTOR INSTALLED
OWNER FURNISHED OWNER INSTALLED
OWNER FURNISHED VENDOR INSTALLED
U/S
UL
UNFIN.
U.H.
U.N.O.
UTIL.
UNDERSIDE
UNDERWRITERS LABORATORY
UNFINISHED
UNIT HEATER
UNLESS NOTED OTHERWISE
UTILITY
VAC.
V.B.
V.BAR.
VAR.
V.A.V.
V.RES.
VENT.
VERT.
VEST.
VIN.
V.C.T.
V.T.
V.W.C.
VIT.
V.C.P.
VOL.
VACUUM
VALVE BOX
VAPOR BARRIER
VARIES
VARIABLE AIR VOLUME
VANDAL RESISTANT
VENTILATION
VERTICAL
VESTIBULE
VINYL
VINYL COMPOSITION TILE
VINYL TILE
VINYL WALL COVERING
VITREOUS
VITRIFIED CLAY PIPE
VOLUME
WL.
W.CAB.
WSCT.
W/C
W.C.
W.H.
WPRF.
WGT.
W.W.F.
W.
W.F.
WIN.
W.G.
W/O
W/
WD.
W.B.
W.P.
W.I.
WALL
WALL CABINET
WAINSCOT
WATER-CEMENT RATIO
WATER CLOSET
WATER HEATER OR WALL HUNG
WATERPROOFING
WEIGHT
WELDED WIRE FABRIC
WEST
WIDE FLANGE
WINDOW
WIRED GLASS
WITHOUT
WITH
WOOD
WOOD BASE
WORKPOINT
WROUGHT IRON
QLTY.
QTY.
Q.T.
QUALITY
QUANTITY
QUARRY TILE
YD. YARD
ZN. ZONE
CONCRETE
GYPSUM BOARD
SEE PARTITION TYPES
SEALANT BOTH SIDES TYP.
(FIRE STOP SEALANT BOTH
SIDES AT RATED PARTITONS)
DECK
DEFLECTION CHANNEL
CEILING RUNNER
3/ 4"
M A
X
G.W.B. SEE
PARTITION TYPES
SEALANT BOTH SIDES TYP.
(FIRE STOP SEALANT BOTH
SIDES AT RATED PARTITIONS)
PROVIDE FIRESAFING IN FLUTES
AT RATED WALLS ABUTTING
SOLID CONCRETE DECK: HW-D-0003
FLUTED DECK: HW-D-0031
1 LAYER 5/8" G.W.B.
MINERAL FIBER INSULATION
5/8" G.W.B.
3 5/8" METAL
STUDS @ 16" O.C.
BASE - SEE FINISH
SCHEDULE FOR TYPE
TRACK RUNNER
FLOOR SLAB
PARTITION
AS DETAILED
P1
A000
Sim
7/
8"
A000
Sim
NOTE:
PROVIDE BACKER BOARD ON ALL
WALLS THAT RECIEVE TILE.
V A
R
IE
S
2" WELDED HOLLOW METAL FRAME
PAINTED - SOLIDLY PACK MINERAL
INSULATION INSIDE FRAMES
FRAME ANCHOR AS RECOMMENDED
BY FRAME MFG.
5/8" G.W.B. EACH SIDE
DOOR
SEE DOOR SCHEDULE
SEALANT, TYP.
DOUBLE 20 GA. METAL
STUDS AT FRAME
2"
VARIES
2" WELDED HOLLOW METAL
FRAME PAINTED - SOLIDLY
PACK MINERAL INSULATION
INSIDE FRAMES
FRAME ANCHOR AS
RECOMMENDED BY FRAME
MF'R.
5/8" G.W.B. EACH SIDE
DOOR - SEE DOOR SCHEDULE
SEALANT, TYP.
DOUBLE 20 GA. METAL
STUDS AT JAMB
2"
DOOR TYPE F
2" VARIES 2"
V A
R
IE
S 2"
FRAME TYPE S
FLUSH
FRAME W/ STOP
DETAIL
A
3" = 1'-0"1 HEAD OF WALL DETAIL
DETAIL
A
3" = 1'-0"2 FOOT OF WALL DETAIL
1/4" = 1'-0"
DOOR AND FRAME TYPES
C
IT
Y O
F C
LE
V E
LA
N D
SHEET NO:
CHECKED BY:
DESIGNED BY:
SCALE:
DELINEATED BY:
PROJECT NAME:
D E
P A
R T M
E N
T O
F P
U B
L
IC
W O
R K
S
C it y o f C le ve la n d
M a yo r' s O ff ic e o f C a p it a l P ro je c ts
D iv is io n o f A rc h it e c tu re
C le ve la n d
C it y H a ll
L a k e si d e A ve n u e
R o o m
A C le ve la n d
-1
P h o n e
-2 x:
-4 a n d S it e
D e ve lo p m e n t
TITLE:
h u ro n r o a d e a s t s u it e c le v e la n d o h
/6
/2
:3
:4
P
M A u to d e s k D o c s /2
-0
C it y o f C le v e la n d R o c k e fe lle r
G re e n h o u s e R
/2
-0
C it y o f C le v e la n d
R o c k e fe lle r G re e n h o u s e G a ra g e
R
.r v t
As indicated
A000
GENERAL INFORMATION
Adam Yaracs
Ty Juan Swanson-Sawyer
IKM, INC
-0
R o c k e fe ll e r
P a rk G re e n h o u s e
C a m p u s
G a ra g e B u il d in g E th
S t, C le v e la n d
O H
GENERAL NOTES
1 DO NOT SCALE DRAWINGS TO DETERMINE INTENDED DIMENSIONS OR TO LAY OUT WORK.
2 FIELD VERIFY EXISTING CONDITIONS. REPORT DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND
CONTRACT DOCUMENTS TO THE ARCHITECT IN WRITING AND OBTAIN CLARIFICATION PRIOR TO
SUBMITTING PROPOSALS OR COMMENCING WORK.
3 DIMENSIONS ARE TO THE FACE OF FINISHED WALL SURFACE UNLESS NOTED OTHERWISE.
4 REFER TO THE REFLECTED CEILING PLANS FOR PROPOSED CEILING HEIGHTS AND COORDINATED LOCATIONS OF ALL ELECTRICAL, HVAC AND FIRE PROTECTION DEVICES TO BE INSTALLED IN OR ON
FINISHED CEILINGS.
5 UNLESS NOTED OR SHOWN OTHERWISE, DUCTWORK, PIPING, CONDUIT AND STRUCTURAL ELEMENTS
ARE NOT TO BE EXPOSED WITHIN FINISHED SPACES.
6 REPLACE OR PATCH DAMAGED FIRE PROOFING MATERIAL THAT HAS BEEN DAMAGED OR REMOVED DUE TO DEMOLITION WORK OR OTHER CONSTRUCTION ACTIVITY. REFER TO THE PROJECT MANUAL
AND THE FIREPROOFING SCHEDULE FOR MATERIAL SPECIFICATIONS AND SPECIFIC DESIGN
REQUIREMENTS FOR EACH ASSEMBLY AFFECTED.
7 MECHANICAL AND/OR ELECTRICAL WORK REQUIRED TO COMPLETE THIS PROJECT MAY REQUIRE WORK IN PORTIONS OF THE EXISTING BUILDING BEYOND THE GENERAL CONTRACT LIMIT LINES OF
ARCHITECTURAL WORK. REMOVAL AND RESTORATION OF EXISTING BUILDING ELEMENTS OR
FINISHES, REPAIRS TO DAMAGED FINISHES, THE ERECTION AND REMOVAL OF TEMPORARY
PARTITIONS AND/OR SIGNAGE ASSOCIATED WITH THIS WORK MUST BE COMPLETED TO THE
SATISFACTION OF THE OWNER AS PART OF THIS PROJECT
8 THE KEYING OF PARTITION TYPES ON THE PLANS IS INTENDED TO AID THE CONTRACTOR IN
UNDERSTANDING THE VARIOUS CONDITIONS LIKELY TO BE ENCOUNTERED. THE CONTRACTOR IS
RESPONSIBLE FOR DETERMINING WHAT MATERIAL (TYPES AND SIZES OF FURRING) IS REQUIRED TO
COMPLETE THE PROJECT AS SHOWN.
9 WHERE NEW PARTITIONS ABUT AND ALIGN WITH EXISTING PARTITIONS OR OTHER SURFACES, FINISHED SURFACES SHALL BE IN THE SAME PLANE.
10 PROVIDE REDUCER STRIPS OR TRANSITION STRIPS WHERE FINISH FLOORING MATERIALS HAVE
DIFFERENT THICKNESSES AND/OR DIFFERENT MATERIALS ABUT.
11 PROVIDE 6”HIGH, 16GA. SHEET METAL REINFORCEMENT FOR WALL MOUNTED EQUIPMENT UNLESS
NOTED OTHERWISE TO BE OF MORE SUBSTANTIAL REINFORCEMENT
12 WOOD USED FOR FRAMING AND BLOCKING SHALL BE FIRE-RETARDANT TREATED WOOD, U.L.
LABELED.
13 RESTORE EXISTING FINISH SURFACES DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES
ASSOCIATED WITH THIS PROJECT.
14 DISCREPANCIES IN THE DOCUMENTS ARE TO BE REPORTED TO THE ARCHITECT IMMEDIATELY.
UNLESS OTHERWISE DIRECTED THE HIGHER DEGREE OF PERFORMANCE, THE BETTER QUALITY, OR
GREATER QUANTITY OF WORK AS INTERPRETED BY THE ARCHITECT SHALL APPLY.
1 1/2" = 1'-0"
PARTITION TYPES
DETAIL
A
3" = 1'-0"4 HM DOOR HEAD
DETAIL
A
3" = 1'-0"3 HM DOOR JAMB
DOOR SCHEDULE - GARAGE
DOOR
# ROOM NAME
DOOR FRAME DETAILS
HARDWARE SET NOTESACTIVE HEIGHT THICKNESS TYPE MATERIAL GLAZING TYPE MATERIAL DEPTH FINISH HEAD JAMB SILL
01A EXISTING GARAGE 3'-0" 7'-0" 1 3/4" F FRP N/A S HM 5 3/4" PAINTED 4 3
4'
27'
50'
8'
1 HOUR FIRE BARRIER
EXIT SIGNS ( DIRECTIONAL ARROW)
SPRINKLERS
LIFE SAFETY PLAN LEGEND
SYMBOL DESCRIPTION
1 HOUR FIRE/SMOKE BARRIER
2 HOUR FIRE BARRIER
FIRE EXTINGUISHER
HORN
STROBE
MANUAL PULL STATION
FIRE ALARM CONTROL PANEL
SMOKE DETECTOR, CEILING MOUNTED
FE
FACP
PD
F
F
F
TRAVEL DISTANCE
ARCHITECTURAL PROJECT AREA
CODE INFORMATION:
PROJECT INTENT:
THE PROJECT INTENT IS TO COMPLETE ALTERATIONS OF THE CITY OF CLEVELAND ROCKEFELLER GREENHOUSE GARAGE. THE INTENT IS TO LIMIT PRIMARY WORK TO THE PROJECT AREAS AS DEFINED BY THE CONSTRUCTION DOCUMENTS, WITH NO CHANGES IN THE USE, CONSTRUCTION, OR OCCUPANCY. NEW WORK PERFORMED SHALL COMPLY WITH CURRENT BUILDING CODES AND REGULATIONS, HOWEVER, THE PROJECT INTENT IS NOT TO BRING ALL STRUCTURES INTO COMPLIANCE WITH CURRENT BUILDING CODES WHERE NO NEW WORK IS BEING PERFORMED. THIS WORK INVOLVES MINOR ALTERATIONS TO EXISTING SPACES AND DOES NOT INTEND TO ADD
OCCUPANT LOAD.
PROJECT SCOPE:
THE PROJECT SHALL BE LIMITED TO ALTERATION WORK AS INDICATED ON THE CONSTRUCTION DOCUMENTS. ALTERATION WORK AND IMPROVEMENTS WITHIN THE PROJECT AREA MAY INCLUDE, BUT SHALL NOT BE LIMITED TO THE FOLLOWING SYSTEMS: HVAC, PLUMBING, FIRE SUPPRESSION, FIRE ALARM, NORMAL POWER, EMERGENCY POWER, DATA AND COMMUNICATION, LIGHTING, INTERIOR PARTITIONS, DOORS AND HARDWARE, AND INTERIOR FINISHES.
OCCUPANCY CLASSIFICATIONS CHAPTER 3 U, UTILITY AND MISCELLANEOUS - GARAGE (UNCHANGED)
ALLOWABLE HEIGHT, STORIES CHAPTER 5 EXISTING CONSTRUCTION (SECTION 504, UNCHANGED)
ALLOWABLE AREA CHAPTER 5 EXISTING CONSTRUCTION (SECTION 506, UNCHANGED)
TYPE OF CONSTRUCTION CHAPTER 6 III-B, EXISTING CONSTRUCTION (UNCHANGED)
FIRE PROETECTION CHAPTER 9 WITHOUT SPRINKLER SYSTEM (UNCHANGED)
OCCUPANT LOAD CHAPTER 10 SECTION 1004
OCCUPANCIES TABLE 1004.1.2
ACCESSORY STORAGE 300 SF GROSS/OCCUPANT FIRST FLOOR 2,288 SF/ 300 = 8 OCCUPANTS
TOTAL CALCULATED OCCUPANT LOAD = 14 OCCUPANTS
TOTAL ACTUAL OCCUPANT LOAD = 0 OCCUPANTS
NUMBER OF EXITS CHAPTER 10 2 EXITS, EXISTING CONSTRUCTION (TABLE 1006.3.1, UNCHANGED)
MAXIMIUM COMMON PATH OF EGRESS CHAPTER 10 100FT (OCC. LOAD < 30) - WITHOUT SPRINKLER SYSTEM (TABLE 1006.2.1)
TRAVEL DISTANCE
EXIT ACCESS TRAVEL DISTANCE CHAPTER 10 300FT - WITHOUT SPRINKLER SYSTEM (TABLE 1017.2)
A
D
B
C
A.1
B.1
C.1
D.1
012345
ELEC. CLOSET
01A
39 SF / 300 GRS
1 OCC.
EXISTING
GARAGE
721 SF / 300 GRS
3 OCC.
FE
FE
FE
EXISTING
GARAGE BAY
1110 SF / 300
GRS
4 OCC.
PROVIDE NEW FIRE
EXTINGUISHER AND WALL
BRACKET PROVIDE NEW FIRE
EXTINGUISHER AND WALL
BRACKET
PROVIDE NEW FIRE
EXTINGUISHER AND WALL
BRACKET
STORAGE
01B
62 SF / 300 GRS
1 OCC.
STORAGE
02D
82 SF / 300 GRS
1 OCC.
EXIT 1
OCCUPANT LOAD: 5
EXISTING WIDTH: 36"
STORAGE
02C
75 SF /
1 OCC.
STORAGE
02B
75 SF / 300 GRS
1 OCC.
STORAGE
02A
80 SF / 300 GRS
1 OCC.
EXIT 2
OCCUPANT LOAD: 8
EXISTING WIDTH : 36"
C
IT
Y O
F C
LE
V E
LA
N D
SHEET NO:
CHECKED BY:
DESIGNED BY:
SCALE:
DELINEATED BY:
PROJECT NAME:
D E
P A
R T M
E N
T O
F P
U B
L
IC
W O
R K
S
C it y o f C le ve la n d
M a yo r' s O ff ic e o f C a p it a l P ro je c ts
D iv is io n o f A rc h it e c tu re
C le ve la n d
C it y H a ll
L a k e si d e A ve n u e
R o o m
A C le ve la n d
-1
P h o n e
-2 x:
-4 a n d S it e
D e ve lo p m e n t
TITLE:
h u ro n r o a d e a s t s u it e c le v e la n d o h
Project North True North
/6
/2
:3
:4
P
M A u to d e s k D o c s /2
-0
C it y o f C le v e la n d R o c k e fe lle r
G re e n h o u s e R
/2
-0
C it y o f C le v e la n d
R o c k e fe lle r G re e n h o u s e G a ra g e
R
.r v t
As indicated
AL100
LIFE SAFETY PLAN
Checker
Author
Designer
-0
R o c k e fe ll e r
P a rk G re e n h o u s e
C a m p u s
G a ra g e B u il d in g E th
S t, C le v e la n d
O H
STATE: OHIO
OHIO BUILDING CODE 2017 (INTERNATIONAL BUILDING CODE 2015 WITH OHIO AMENDMENTS)
• ICC/ANSI A117.1-2009 WITH AMENDMENTS
• EXISTING BUILDING CODE CHAPTER 34
OHIO ENERGY CODE 2017 (INTERNATIONAL ENERGY CONSERVATION CODE 2012/ASHRAE 90.1-2010 WITH OHIO
AMENDMENTS)
OHIO MECHANICAL CODE 2017 (INTERNATIONAL MECHANICAL CODE 2015 WITH OHIO AMENDMENTS)
OHIO PLUMBING CODE 2017 (INTERNATIONAL PLUMBING CODE 2015 WITH OHIO AMENDMENTS)
APPLICABLE CODES:
TRAVEL DISTANCE - GARAGE
START POINT DISTANCE EXIT NUMBER
A 27' 1
B 58' 2
A L
3/16" = 1'-0"1 FIRST FLOOR LIFE SAFETY PLAN - GARAGE
SHRUBS TO BE REMOVED FOR
ACCESS TO WALLS FOR MASONRY
REPAIRS AND IMPROVEMENTS
PROTECT EXISTING DOGWOOD
TREE AND UTILITY POLE THROUGH
ENTIRETY OF CONSTRUCTION
PROTECT ALL VEGETATION IN THIS AREA
THROUGHOUT ENIRETY OF CONSTRUCTION
PROTECT ALL VEGITATION IN
THIS AREA THROUGHOUT
ENIRETY OF CONSTRUCTION
PROTECT ALL VEGETATION IN THIS AREA
THROUGHOUT ENIRETY OF CONSTRUCTION
PROTECT ALL
VEGITATION IN THIS AREA
THROUGHOUT ENIRETY
OF CONSTRUCTION
ADMIN BUILDING
GARAGE BUILDING
NURSERY
NURSERY
SHRUBS TO BE REMOVED FOR
ACCESS TO WALLS FOR MASONRY
REPAIRS AND IMPROVEMENTS
2.0
1.0
4.0
3.0
5.0
6.0
8.0
7.0
DAWN REDWOOD. REMOVE EXCESS ASPHALT
PAVEMENT AROUND TREE WITHOUT
DAMAGING ROOTS. COORDINATE EXTENT OF
ASPHALT REMOVAL WITH OWNER. PROTECT
TREE THROUGH ENTIRETY OF
CONSTRUCTION.
NEW CONCRETE SIDEWALK
CONNECTION
NEW CONCRETE CONNECTION
TOPDRESS AREA WITH TOPSOIL AND 2" OF
DOUBLE SHREDDED BARK MULCH AS DIRECTED.
CONTRACT LIMIT LINE
NOTE: LANDSCAPING PLAN IS FOR INFORMATOIN ON
PROTECTION OF EXISTING LANDSCAPING AS NOTED.
EXISTING CONCRETE
LANDSCAPING PLAN LEGEND
EXISTING ASPHALT
EXISTING STONE PATH
EXISTING WOOD LANDSCAPE BARRIER
EXISTING BUILDING
EXISTING BRICK LANDSCAPE BARRIER
AREA OF LANDSCAPE PROTECTION OR WORK
EXISTING GRAVEL DRIVE
PROTECT TREE
DURING
CONSTRUCTION
REMOVE EXCESS ASPHALT
AROUND TREE AND
PROTECT ROOTS
IMAGE 1.0
SUPPLEMENTAL IMAGES
IMAGE 2.0
SHRUBS TO BE REMOVED AS
REQ'D TO ACCESS MASONRY
WALLS FOR REPAIRS.
IMAGE 3.0
IMAGE 5.0
IMAGE 7.0
IMAGE 4.0
IMAGE 6.0
IMAGE 8.0
SHRUBS TO BE
REMOVED AS REQ'D
TO ACCESS MASONRY
WALLS FOR REPAIRS
PROTECT VEGETATION
THROUGHOUT
CONSTRUCTION
SHRUBS TO BE
REMOVED AS REQ'D
TO ACCESS MASONRY
WALLS FOR REPAIR
PROTECT VEGETATION
THROUGHOUT
CONSTRUCTION
SHRUBS TO BE
REMOVED AS REQ'D
TO ACCESS MASONRY
WALLS FOR REPAIRS
PROTECT VEGETATION
THROUGHOUT
CONSTRUCTION
SHRUBS TO BE
REMOVED AS REQ'D
TO ACCESS MASONRY
WALLS FOR REPAIRS
PROTECT VEGETATION
THROUGHOUT
CONSTRUCTION
SHRUBS TO BE
REMOVED AS REQ'D
TO ACCESS MASONRY
WALLS FOR REPAIRS
PROTECT VEGETATION
THROUGHOUT
CONSTRUCTION
SHRUBS TO BE
REMOVED AS REQ'D
TO ACCESS MASONRY
WALLS FOR REPAIRS
PROTECT VEGETATION
THROUGHOUT
CONSTRUCTION
C
IT
Y O
F C
LE
V E
LA
N D
SHEET NO:
CHECKED BY:
DESIGNED BY:
SCALE:
DELINEATED BY:
PROJECT NAME:
D E
P A
R T M
E N
T O
F P
U B
L
IC
W O
R K
S
C it y o f C le ve la n d
M a yo r' s O ff ic e o f C a p it a l P ro je c ts
D iv is io n o f A rc h it e c tu re
C le ve la n d
C it y H a ll
L a k e si d e A ve n u e
R o o m
A C le ve la n d
-1
P h o n e
-2 x:
-4 a n d S it e
D e ve lo p m e n t
TITLE:
h u ro n r o a d e a s t s u it e c le v e la n d o h
/6
/2
:3
:5
P
M A u to d e s k D o c s /2
-0
C it y o f C le v e la n d R o c k e fe lle r
G re e n h o u s e R
/2
-0
C it y o f C le v e la n d
R o c k e fe lle r G re e n h o u s e G a ra g e
R
.r v t
As indicated
LS100
LANDSCAPING PLAN
Adam Yaracs
Steven Stauffer
IKM Architecture
-0
R o c k e fe ll e r
P a rk G re e n h o u s e
C a m p u s
G a ra g e B u il d in g E th
S t, C le v e la n d
O H
L S
3/32" = 1'-0"1 LANDSCAPING PLAN
BUILDING DESIGN CRITERIA
GOVERNING CODE: 2017 OHIO BUILDING CODE IN CONJUNCTION WITH ASCE 7-10
RISK CATEGORY: II
FLOOR LIVE LOADS:
OFFICES (INCLUDES 15 PSF PARTITION LOAD) 65 PSF
STAIRWAYS 100 PSF
STORAGE 125 PSF
LIVE LOAD REDUCTION PER ASCE-7
ROOF LIVE LOAD 20 PSF
SNOW LOAD:
GROUND SNOW LOAD, Pg: 30 PSF FLAT ROOF SNOW LOAD, Pf: 30 PSF SNOW EXPOSURE FACTOR, Ce: 1.0
SNOW IMPORTANCE FACTOR: 1.0
THERMAL FACTOR, Ct: 1.0
SNOW DRIFT: PER ASCE-7
WIND LOAD:
ULTIMATE DESIGN WIND SPEED (Vult): 115 MPH NOMINAL DESIGN WIND SPEED (Vasd): 90 MPH
WIND EXPOSURE: C
INTERNAL PRESSURE COEFFICIENT: ±0.18
COMPONENTS AND CLADDING: SEE TABLE S002A
SEISMIC LOAD:
SEISMIC IMPORTANCE FACTOR 1.0
SITE SPECTRAL RESPONSE ACCELERATION (Ss): 0..184
SITE SPECTRAL RESPONSE ACCELERATION (S1): 0..058
SEISMIC SITE CLASS: D
DESIGN SPECTRAL RESPONSE ACCELERATION (Sds): 0.196 DESIGN SPECTRAL RESPONSE ACCELERATION (Sd1): 0..093
SEISMIC DESIGN CATEGORY: D
SEISMIC FORCE RESISTING SYSTEM: STRUCTURAL SYSTEM NOT
SPECIFICALLY DETAILED FOR
SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR R: 3.0
SEISMIC BASE SHEAR (V): 0.085W KIPS
SEISMIC RESPONSE COEFFICIENT (Cs): 0.085
ANALYSIS METHOD: EQUIVALENT LATERAL FORCE
SAFE ROOM DESIGN CRITERIA (IF APPLICABLE)
GENERAL CONDITIONS:
1. SEE SPECIFICATIONS FOR QUALITY OF CONSTRUCTION REQUIRED, QUALITY
OF WORK, MANUFACTURING AND INDUSTRY STANDARDS, PHYSICAL
PROPERTIES OF MATERIALS, CONFORMANCE TO CODES AND
REGULATIONS GUARANTEE AND WARRANTY REQUIREMENTS.
2. SEE ARCHITECTURAL, HVAC, PLUMBING, ELEVATOR, FIRE PROTECTION &
ELECTRICAL DRAWINGS FOR OTHER PERTINENT INFORMATION RELATED TO
STRUCTURAL WORK AND COORDINATE AS REQUIRED. CONTRACTOR SHALL
COORDINATE STRUCTURAL DRAWINGS WITH ALL OTHER DRAWINGS WITHIN
THE CONTRACT DOCUMENTS.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND
CONDITIONS RELATED TO EXISTING CONSTRUCTION, EXISTING SERVICES,
AND THE SITE BEFORE BEGINNING WORK.
4. CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LIVE LOADS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DESIGN REQUIRED TO
SUPPORT CONSTRUCTION EQUIPMENT USED IN CONSTRUCTING THIS
PROJECT. ALL EQUIPMENT SUPPORT DESIGN SHALL BE PERFORMED BY AN
ENGINEER LICENSED IN THE STATE OF THE PROJECT. SHORING AND
RESHORING IS THE RESPONSIBILITY OF THE CONTRACTOR.
5. IF MATERIALS, QUANTITIES, STRENGTHS OR SIZES INDICATED BY THE
DRAWINGS OR SPECIFICATIONS ARE NOT IN AGREEMENT WITH THESE
NOTES, THE BETTER QUALITY AND/OR QUANTITY, STRENGTH OR SIZE
INDICATED, SPECIFIED OR NOTED SHALL BE PROVIDED.
6. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE FOLLOWING ITEMS
THAT WILL NOT BE REVIEWED BY THE OWNER, ARCHITECT OR ENGINEER:
A. DEVIATIONS FROM CONTRACT DOCUMENTS.
B. DIMENSIONS, ELEVATIONS AND CONDITIONS TO BE CONFIRMED AND
CORRELATED AT THE SITE.
C. FABRICATION PROCESS INFORMATION.
D. MEANS, METHODS, TECHNIQUES, PROCEDURES OF CONSTRUCTION
AND CONSTRUCTION SAFETY.
E. COORDINATION OF THE WORK OF ALL TRADES.
7. ANY CHANGES TO THE STRUCTURAL SYSTEMS SHALL BE REDESIGNED BY A
PROFESSIONAL ENGINEER AT NO COST TO THE OWNER OR THE A/E AND
SUBMITTED TO THE A/E FOR REVIEW. SUBMITTAL SHALL BE
ACKNOWLEDGED IN WRITING BEFORE BEGINNING CONSTRUCTION. IF
CHANGES ARE MADE WITHOUT WRITTEN APPROVAL SUCH CHANGES SHALL
BE THE LEGAL AND FINANCIAL RESPONSIBILITY OF THE PARTY MAKING THE
CHANGE TO REPLACE OR REPAIR THE CONDITION AS DIRECTED BY THE A/E.
EXISTING CONDITIONS:
1. THE EXISTING CONDITIONS INDICATED ON THE DRAWINGS ARE BASED ON
EXISTING DRAWINGS BY THE CITY OF CLEVELAND, DATED APRIL 1938. THE
CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING
CONDITIONS AND DIMENSIONS. CONTRACTOR IS TO REPORT ANY
DISCREPANCIES TO THE A/E PRIOR TO PROCEEDING.
2. THE INFORMATION SHOWN ON THE ARCHITECTURAL AND STRUCTURAL
CONSTRUCTION DOCUMENTS IS BASED ON ASSUMPTIONS OF THE EXISTING
BUILDING CONSTRUCTION. ORIGINAL CONSTRUCTION DOCUMENTS WERE
NOT AVAILABLE FOR THE PREPARATION OF THESE DOCUMENTS. THE
CONTRACTOR IS TO NOTIFY THE A/E IF CONDITIONS DIFFERING FROM
THOSE STATED ARE UNCOVERED IN THE DEMOLITION PROCESS.
3. DUE TO THE AGE OF THE BUILDING, IT IS LIKELY THAT LEAD-BASED PAINT IS
PRESENT ON MOST OR ALL PAINTED SURFACES. THE CONTRACTOR SHALL
COMPLY WITH THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
(OSHA) LEAD IN CONSTRUCTION STANDARD (29 CODE OF FEDERAL
REGULATIONS, PART 1926.62) AND OTHER APPLICABLE REGULATORY
STANDARDS TO PROTECT WORKERS FROM EXPOSURE TO AIRBORNE LEAD
DUST.
4. CONTRACTOR IS RESPONSIBLE TO UNCOVER AND VISUALLY FIELD VERIFY
THE EXISTING CONSTRUCTION PRIOR TO THE START OF ANY WORK
AFFECTING THE EXISTING STRUCTURE. CONTRACTOR IS TO REPORT ANY
CHANGES OR DISCREPANCIES FROM THOSE SHOWN TO THE A/E.
DEMOLITION:
1. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
DEMOLITION PROCEDURE AND SEQUENCE TO ENSURE THE SAFETY OF THE
EXISTING BUILDING AND ITS COMPONENT PARTS DURING DEMOLITION AND
FUTURE ERECTION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION
OF ANY OR ALL TEMPORARY BRACING, GUYS OR TIE-DOWNS WHICH MAY BE
NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE
PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT.
2. THE CONTRACTOR SHALL SUPPORT, BRACE AND SECURE EXISTING
STRUCTURE AS REQUIRED. CONTRACTOR IS SOLELY RESPONSIBLE FOR
THE SAFETY OF THE EXISTING BUILDING DURING DEMOLITION AND
CONSTRUCTION. FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS
AND CONDITIONS WHICH AFFECT THE DEMOLITION AND NEW
CONSTRUCTION.
3. THE EXTENT OF THE WORK SHOWN SHALL INCLUDE REMOVAL AND
DISPOSAL, OFF SITE, OF THE ELEMENTS INDICATED WITHIN THESE
DEMOLITION DRAWINGS UNO.
4. THE EXISTING STRUCTURE SHALL BE DISASSEMBLED IN A MANNER WHICH
DOES NOT DAMAGE OR DEFORM ANY EXISTING STRUCTURE TO REMAIN.
EXISTING SLABS SHALL BE SAWCUT IN A MANNER WHICH DOES NOT CAUSE
THE SLAB SUPPORTING MEMBER TO BE CUT OR DAMAGED.
5. CONFORM TO ALL APPLICABLE CODES FOR DEMOLITION OF STRUCTURES,
SAFETY OF EXISTING AND ADJACENT STRUCTURES, DUST CONTROL, AND
DISPOSAL.
6. USE OF EXPLOSIVES SHALL NOT BE PERMITTED.
7. EXISTING SLABS SHALL BE CORE DRILLED AT RE-ENTRANT CORNERS OF
NEW FLOOR OPENINGS TO PREVENT OVER CUTTING.
8. THE DEMOLISHED STRUCTURE SHALL BE REDUCED TO A WEIGHT AND
TRANSPORTED ACROSS THE EXISTING STRUCTURE IN A MANNER WHICH
DOES NOT OVERSTRESS THE EXISTING BUILDING STRUCTURE.
9. FRAMING SHALL BE REMOVED ONLY AFTER THE LOAD SUPPORTED BY THAT
FRAMING IS REMOVED. THE FRAMING REMOVAL PROCESS SHALL NOT
DEFORM OR INDUCE STRESS TO EXISTING FRAMING TO REMAIN.
CAST IN PLACE CONCRETE:
1. CODES AND STANDARDS:
ALL CAST-IN-PLACE CONCRETE WORK, DETAILING, FABRICATION AND
PLACING OF REBARS AND CONCRETE SHALL BE GOVERNED BY CONTRACT
DOCUMENTS AND LATEST EDITIONS OF:
A. ACI 318 - BUILDING CODE REQUIREMENT FOR STRUCTURAL CONC.
B. ACI 315 - DETAILS AND DETAILING OF CONCRETE REINFORCEMENT.
C. ACI 301 - SPECIFICATION OF STRUCTURAL CONCRETE.
D. ACI 117 - SPECIFICATION FOR TOLERANCES FOR CONCRETE
CONSTRUCTION AND MATERIALS.
E. ACI 305 - SPECIFICATION OF HOT WEATHER CONCRETING.
F. ACI 306 - SPECIFICATION OF COLD WEATHER CONCRETING.
G. FIELD REFERENCE MANUAL MUST BE PRESENT ON SITE.
H. CONCRETE REINFORCING STEEL INSTITUTE (CRSI).
2. CONCRETE SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE
STRENGTH AT 28 DAYS:
MIX USAGE fc (PSI) W/C AIR CONTENT
A. LEAN CONCRETE 1,500 - -
B. ALL INTERIOR CONCRETE 4,000 0.45 -
C. ALL EXPOSED/EXTERIOR CONC. 4,000 0.45 5%-7%
D. FOUNDATIONS 4,000 0.45 -
3. MATERIALS:
A. PORTLAND CEMENT: ASTM C150, TYPE I OR III.
B. AGGREGATES: ASTM C33.
C. AIR-ENTRAINING: ASTM C260.
D. REINFORCING BARS: ASTM 615 Fy = 60 KSI.
E. WELDABLE REINFORCING BARS: ASTM 706, Fy = 60 KSI.
F. WELD WIRE FABRIC: ASTM A82 AND A185, Fy = 65 KSI (PLAIN).
G. ADMIXTURES:
a. LOW OR MID RANGE REDUCER: ASTM C494, TYPE A OR D.
b. HIGH RANGE WATER REDUCER: ASTM C494, TYPE F OR G.
c. ACCELERATOR: ASTM A494 TYPE C OR E.
H. FLY ASH: ASTM C618, TYPE C OR F.
4. SUBMITTALS:
A. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL WHICH
INCLUDE ERECTIONS PLANS, POUR SEQUENCE (IF APPLICABLE),
CONSTRUCTION JOINTS AND/OR EXPANSION JOINTS, ELEVATIONS
AND REBAR BENDING SCHEDULES.
B. SUBMIT A MIX DESIGN FOR EACH MIX USAGE REQUIRED ON THE
PROJECT.
C. SUBMIT PRODUCT LITERATURE FOR ADMIXTURES AND CURING
COMPOUNDS.
D. SUBMIT REPORTS FOR ALL REQUIRED TESTING AND INSPECTIONS.
E. NO CONCRETE SHALL BE PLACED UNTIL ALL SUBMITTALS HAVE BEEN
APPROVED BY STRUCTURAL ENGINEER.
5. CONTINGENCY:
A. FURNISH, FABRICATE AND PLACE 2 TONS OF REINFORCING BARS TO
BE USED AS DIRECTED BY THE ARCHITECT/ENGINEER.
B. PROVIDE LEAN CONCRETE UNDER FOUNDATIONS FOR EARTH FILL
DUE TO ACCIDENTAL OVER EXCAVATION OR POOR SOIL CONDITIONS.
C. CONTRACTOR SHALL REIMBURSE OWNER FOR ALL UNUSED
ALLOWANCES LISTED ABOVE.
6. OPENINGS:
A. OPENINGS SHOWN ARE FOR BIDDING PURPOSES ONLY. RECONCILE
THEIR EXACT SIZES AND LOCATIONS WITH ARCHITECTURAL AND MEP
REQUIREMENTS BEFORE PROCEEDING WITH WORK.
B. IF ANY OPENING NOT SHOWN ON THE PLANS IS REQUIRED, SECURE
APPROVAL OF THE ARCHITECT OR ENGINEER BEFORE PROCEEDING.
C. PROVIDE 1/2 NUMBER OF BARS INTERRUPTED PLUS ONE TYPICAL
EACH FACE OF OPENING. PROVIDE (2) #5 BARS AROUND ALL SLAB
AND WALL OPENINGS, EXTENDING 2'-0" BEYOND OPENING IN EVERY
DIRECTION UNO.
D. OPENINGS NOT EXCEEDING 16" x 16" MAY BE SLEEVED AS REQUIRED
BY WORKING THE REINFORCING AROUND THEM.
7. FOOTINGS, WALLS, COLUMNS AND PIERS:
A. DOWELS IN FOOTING TO MATCH VERTICAL COLUMN, PIER OR WALL
REINFORCING.
B. WALLS AND FOOTING CORNER BARS TO MATCH HORIZONTAL
REINFORCING.
8. BEAMS:
A. PROVIDE A MINIMUM OF (3) - #5 TOP REINFORCING BARS IN BEAMS
WHERE NO OTHER TOP BARS ARE AVAILABLE FOR SUPPORTING
STIRRUPS. ALL SPANDREL AND EDGE BEAMS SHALL HAVE A MINIMUM
OF (3) #5 TOP REINFORCING BARS AND CLOSED STIRRUPS
CONTINUOUS ACROSS THE SPAN.
B. MINIMUM 8” BEARING ON MASONRY WALLS.
MASONRY:
1. CODES AND STANDARDS:
ALL MASONRY CONSTRUCTION SHALL BE GOVERNED BY
CONTRACT DOCUMENTS AND LATEST EDITIONS OF:
A. BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES TMS 402 AND SPECIFICATION FOR
MASONRY STRUCTURES TMS 602.
B. BRICK INSTITUTE OF AMERICA (BIA).
C. NATIONAL CONCRETE MASONRY ASSOCIATION (NCMA).
2. MATERIALS:
A. CONCRETE BLOCK:
a. ASTM C90.
b. MINIMUM COMPRESSIVE STRENGTH = 2,800 PSI.
c. NET COMPRESSIVE STRENGTH, fm = 2,500 PSI.
d. MEDIUM WEIGHT = 135 PCF.
B. MORTAR:
a. ASTM C270, TYPE S.
b. MINIMUM COMPRESSIVE STRENGTH = 1,800 PSI.
C. GROUT:
a. ASTM C476, COARSE TYPE E.
b. MINIMUM COMPRESSIVE STRENGTH = 2,500 PSI.
c. 3/8" MAXIMUM SIZE COARSE AGGREGATE.
D. HORIZONTAL REINFORCING:
a. STANDARD LADDER TYPE - 9 GA.
b. MILL GALVANIZED FINISH.
c. PLACE 8" OC BELOW GRADE AND 16" OC ABOVE
GRADE.
E. VERTICAL REINFORCING:
a. ASTM A615.
b. MINIMUM YIELD STRENGTH = 60 KSI.
3. SUBMITTALS:
A. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL
WHICH INCLUDE ERECTION PLANS, ELEVATIONS AND
REBAR BENDING SCHEDULES.
B. SUBMIT PRODUCT LITERATURE FOR ALL MASONRY
TIES USED ON THE PROJECT.
MASONRY CONT:
4. MASONRY LINTELS:
A. THE CONTRACTOR SHALL SUPPLY BOND BEAM LINTELS OVER
ALL MASONRY OPENINGS AND RECESSES UNO. BOND BEAM
LINTELS SHALL BE AS SHOWN IN THE SCHEDULE IN THE
DETAIL SHEETS.
B. BOTTOM COVER SHALL BE 2" AND FILL WITH 2500 PSI GROUT.
C. ALL LINTELS SHALL HAVE A MINIMUM BEARING OF 8" OR 1"
PER FOOT OF CLEAR SPAN, WHICHEVER IS LARGER.
D. EACH BEARING END SHALL HAVE A MINIMUM 24" x 3 COURSES
OF SOLID MASONRY.
E. ALL REINFORCING TO EXTEND 2'-0" INTO EACH BEARING END.
F. ALL CANTILEVERED LINTELS SHALL EXTEND HAVE A MINIMUM
BACKSPAN OF 1.5 TIMES OPENING DIMENSION WITH A
STANDARD HOOK ON THE TOP REINFORCING.
5. STEEL LINTELS:
A. BOTTOM PLATES ON BEAMS SHALL BR 1/2" LESS IN WIDTH
THAN THE WALL THICKNESS AND EXTEND FOR THE FULL
LENGTH OF BEAM EXCLUDING THE BEARING ENDS UNO.
B. BOTTOM PLATES SHALL BE WELDED TO BEAM WITH A 1/4"
FILLET WELD 3" LONG ON BOTH SIDES @ 8" ON CENTER,
STAGGER PLACEMENT OF WELDS FROM SIDE TO SIDE.
C. BOTTOM PLATE SHALL BE A MINIMUM OF 5/16" TYP UNO.
D. ALL LINTELS SHALL HAVE A MINIMUM BEARING OF 8" OR 1"
PER FOOT OF CLEAR SPAN, WHICHEVER IS LARGER.
E. EACH BEARING END SHALL HAVE A MINIMUM 24" x 3 COURSES
OF SOLID MASONRY.
6. LOOSE LINTELS FOR VENEERS:
A. THE CONTRACTOR SHALL SUPPLY LOOSE LINTEL ANGLES
OVER ALL MASONRY OPENINGS AND RECESSES UNO.
LINTELS NOT SCHEDULED ON DRAWINGS SHALL CONSIST OF
A SINGLE ANGLE WITH 3 1/2" LEGS HORIZONTAL FOR EACH 4"
OF WALL THICKNESS, ANGLES SHALL BE AS SHOWN IN THE
SCHEDULE IN THE DETAIL SHEETS.
B. LINTELS INCLUDING BEARING PLATES AND ANCHORS
EXPOSED TO THE EXTERIOR OR IN EXTERIOR WALLS SHALL
BE GALVANIZED.
7. BOND BEAMS:
A. PROVIDE AT THE FOLLOWING LOCATIONS:
a. FLOOR ELEVATIONS.
b. TOP OF PARAPETS.
c. 4'-0" OC FOR EXTERIOR SHAFT WALLS.
B. REINFORCING TO BE MINIMUM (2) #5 TYP UNO.
8. JOINTS:
A. PROVIDE CONTROL JOINTS AT THE FOLLOWING LOCATIONS:
a. MINIMUM SPACING OF 24'-0" OC OR 2 TIMES WALL
HEIGHT.
b. 4 FEET FROM CORNER.
c. CHANGE IN WALL ELEVATION.
d. CHANGE IN WALL THICKNESS.
9. CONSTRUCTION:
A. ALL UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON
HEAD, BED (FACE SHELLS) WEBS, AND COLLAR JOINTS, UNO.
B. PROVIDE 3 COURSES x 32" WIDE SOLID GROUTED MASONRY.
CENTERED UNDER EACH STEEL BEAM AT BEARING AND END
OF EACH LINTEL.
C. PROVIDE 2 COURSES x 32" WIDE SOLID GROUTED MASONRY
CENTERED UNDER EACH JOIST AT BEARING.
D. PROVIDE CONTINUOUS 1 COURSE SOLID GROUTED MASONRY
UNDER PRECAST PLANKS OR CAST IN PLACE SLAB.
E. GROUT SOLID A MINIMUM OF ONE COURSE BELOW ANY
CHANGE IN WALL THICKNESS.
F. ALL MASONRY BELOW GRADE SHALL BE GROUTED SOLID.
G. THE FIRST COURSE OF ALL WALLS SHALL BE GROUTED
SOLID.
H. ALL GROUTING OF MASONRY WALLS IS TO BE BY THE LOW-
LIFT GROUTING METHOD (MAXIMUM LIFT HEIGHT 5'-0").
CONSOLIDATE EACH LIFT BY MECHANICAL VIBRATION TO
ENSURE COMPLETE FILLING OF CELLS.
I. ALL VERTICALLY REINFORCED WALLS SHALL HAVE DOWELS
INTO FOUNDATION THAT MATCH THE WALL BAR SIZE AND
SPACING.
J. JOINT REINFORCING SHALL BE BENT AROUND CORNERS, BUT
SHALL NOT BE CONTINUOUS THROUGH EXPANSION OR
CONTROL JOINTS.
K. EXTERIOR WALLS, SHAFT WALLS AND BEARING WALLS TO BE
REINFORCED WITH MINIMUM IS #5 AT 48" OC UNO.
L. ALL INTERIOR NON-BEARING MASONRY WALLS TO BE
REINFORCED WITH #5 AT 96" OC THE MAX HEIGHT LIMITS ARE
AS FOLLOWS:
a. 6" CMU MAX HEIGHT = 14'-0".
b. 8" CMU MAX HEIGHT = 18'-0".
c. 10" CMU MAX HEIGHT = 20'-0".
d. 12" CMU MAX HEIGHT = 24'-0".
M. TEMPORARILY BRACE ALL MASONRY WALLS TO PROVIDE
STABILITY DURING CONSTRUCTION UNTIL THE DESIGNED
STRUCTURE IS COMPLETED AND CAN STABILIZE THE WALLS.
10. MISCELLANEOUS:
A. DO NOT USE CALCIUM CHLORIDE OR ANY ADMIXTURES THAT
CONTAINS CALCIUM CHLORIDE IN THE MORTAR OR GROUT.
B. PREMIXED MASONRY CEMENT IS PROHIBITED.
C. DO NOT USE FROZEN MATERIALS OR MATERIALS MIXED OR
COATED WITH ICE OR FROST.
D. DO NOT BUILD ON FROZEN WORK, REMOVE AND REPLACE
MASONRY WORK DAMAGED BY FROST OR FREEZING.
REBAR LAP SPLICE REQUIREMENTS (MIN.)
LOCATION BEAMS AND FOUNDATIONS
BAR
f'c 3000 PSI 4000 PSI
#3
#4
#5
#6
#7
#8
22" 19"
29" 25"
36" 31"
36" 36"
42" 42"
42" 42"
WALLS AND SLABS
3000 PSI 4000 PSI
16" 16"
17" 16"
26" 22"
36" 36"
42" 42"
42" 42"
GENERAL NOTES:
LAP SPLICE LENGTHS ABOVE APPLY TO ALL REINFORCING BARS FOR THIS PROJECT,
UNLESS SPECIFICALLY NOTED OTHERWISE IN THESE PLANS.
ALL LAP SPLICE PROVIDED ABOVE ARE NOT NORMAL WEIGHT CONCRETE AND
GRADE 60 REINFORCING BARS IN TENSION, SPLICES FOR WALL AND SLAB BARS ARE
BASED ON A MINIMUM OF 1" CLEAR COVER.
FOR LIGHTWEIGHT AGGREGATE CONCRETE, MULTIPLY THE TABULATED BY 1.3.
LAP SPLICES FOR GRADE BEAM TOP BARS SHALL BE PLACED IN THE CENTER OF
THE SPAN BETWEEN DRILLED SHAFTS (OR PILES). LAP SPLICES FOR GRADE BEAM
BOTTOM BARS SHALL BE PLACED DIRECTLY ABOVE A DRILLED SHAFT (OR PILE).
1111 Superior Avenue, Suite 2100 | Cleveland, OH 44114
(216) 861-2020 www.osborn-eng.com
C
IT
Y O
F C
LE
V E
LA
N D
SHEET NO:
CHECKED BY:
DESIGNED BY:
SCALE:
DELINEATED BY:
PROJECT NAME:
D E
P A
R T M
E N
T O
F P
U B
L
IC
W O
R K
S
C it y o f C le ve la n d
M a yo r' s O ff ic e o f C a p it a l P ro je c ts
D iv is io n o f A rc h it e c tu re
C le ve la n d
C it y H a ll
L a k e si d e A ve n u e
R o o m
A C le ve la n d
-1
P h o n e
-2 x:
-4 a n d S it e
D e ve lo p m e n t
TITLE:
h u ro n r o a d e a s t s u it e c le v e la n d o h
/6
/2
:1
:3
A
M C
R e v it -T e m p \J
C
L E
R o c k e fe lle r_
R c h e tm a n .r v t
As indicated
S001G
GENERAL NOTES
BTH
CDH
CDH
-0
C it y o f C le v e la n d
R o c k e fe ll e r
G re e n h o u s e
E th
S t, C le v e la n d
O H
CONCRETE REBAR LAP SPLICE (CLASS B) - Fc = 5000 PSI
REBAR SIZE
3/4" COVER 1 1/2" COVER 2" COVER 3" COVER
TOP OTHER TOP OTHER TOP OTHER TOP OTHER
#3 16" 16" 16" 16" 16" 16" 16" 16"
#4 22" 17" 18" 16" 18" 16" 18" 16"
#5 32" 25" 22" 17" 22" 17" 22" 17"
#6 44" 34" 26" 20" 26" 20" 26" 20"
#7 70" 54" 43" 33" 38" 29" 38" 29"
#8 87" 67" 54" 42" 44" 34" 44" 34"
#9 105" 81" 67" 52" 54" 42" 49" 38"
#10 126" 97" 82" 63" 66" 51" 55" 43"
#11 147" 114" 97" 75" 80" 61" 61" 47"
#14 194" 149" 132" 102" 109" 84" 81" 62"
#18 292" 225" 209" 161" 176" 135" 133" 103"
MASONRY REBAR LAP AND SPLICE LENGTH TABLE
BAR SIZE
f'm = 2500 PSI , Fy=60 KSI REINF, NON-COATED REBAR AND 1 1/2" COVER
CENTERED IN CELL EA. FACE OF CELL
8" CMU 10" CMU 12" CMU 8" CMU 10" CMU 12" CMU
#3 12" 12" 12" 15" 15" 15"
#4 12" 12" 12" 26" 26" 26"
#5 18" 14" 12" - 46" 41"
#6 34" 26" 22" - - 77"
#7 47" 36" 29" - - -
#8 71" 55" 45" - - -
CONCRETE REBAR DEVELOPMENT LENGTH - Fc = 5000 PSI
REBAR SIZE
3/4" COVER 1 1/2" COVER 2" COVER 3" COVER
TOP OTHER TOP OTHER TOP OTHER TOP OTHER
#3 12" 12" 12" 12" 12" 12" 12" 12"
#4 17" 13" 14" 12" 14" 12" 14" 12"
#5 25" 19" 17" 13" 17" 13" 17" 13"
#6 34" 26" 20" 16" 20" 16" 20" 16"
#7 54" 42" 33" 26" 29" 23" 29" 23"
#8 67" 51" 42" 32" 34" 26" 34" 26"
#9 81" 62" 52" 40" 42" 32" 38" 29"
#10 97" 75" 63" 49" 51" 39" 43" 33"
#11 114" 87" 75" 58" 61" 47" 47" 36"
#14 149" 115" 102" 78" 84" 65" 62" 48"
#18 225" 173" 161" 124" 135" 104" 103" 79"
CAST IN PLACE CONCRETE CONT:
9. SLAB-ON-GRADE:
A. PLACE REINFORCING AT MID-DEPTH FOR THICKNESS 5" OR LESS
AND AT 1/3 DEPTH FROM TOP FOR THICKNESS GREATER THAN 5".
B. PROVIDE #4 x 3'-0" AT MID-DEPTH OF SLAB PERPENDICULAR TO ANY
DISCONTINUOUS CONTROL JOINTS OR AT RE-ENTRANT SLAB
CORNERS.
C. PROVIDE SAWCUT CONTROL JOINTS IN ALL SLABS ON GRADE. THE
MAXIMUM SPACING OF JOINTS SHALL BE 36 TIMES THE SLAB
THICKNESS IN BOTH DIRECTIONS, UNLESS OTHERWISE NOTE.
10. SPLICES:
A. REINFORCING BARS LAP SPLICE LENGTHS SHALL CONFORM WITH
THE MINIMUM LAP SPLICE TABLE.
B. MECHANICAL BAR SPLICES DEVICES THAT PROVIDE A FULL
TENSION SPLICE WITH A CAPACITY OF 125 PERCENT OF THE BAR
YIELD STRENGTH MAY BE USED.
C. STAGGER SPLICES IN WALLS SO THAT NO MORE THAN 1/3 OF THE
REINFORCING IS SPLICED IN ANY GIVEN CROSS SECTION.
D. PROVIDE CLASS B TENSION LAP SPLICES FOR HORIZONTAL AND
VERTICAL WALL REINFORCING.
11. JOINTS:
A. CONSTRUCTION JOINTS PERMITTED ONLY WHERE SHOWN OR AS
APPROVED BY STRUCTURAL ENGINEER.
B. ALL CONSTRUCTION JOINTS BELOW GRADE SHALL HAVE WATER
STOPS UNO.
C. NO HORIZONTAL CONSTRUCTION JOINT WILL BE PERMITTED IN
BEAM, SLABS AND WALLS UNLESS SPECIFICALLY SHOWN IN THE
DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER.
D. IN WALL CONSTRUCTION, PROVIDE KEYED CONSTRUCTION JOINT
AT A MAXIMUM OF 30'-0" ON CENTER AND LOCATED 8'-0" FROM
COLUMN, WALL OPENING OR CORNER.
E. IN BEAM, SLAB AND WALL CONSTRUCTION, PROVIDE KEYED
CONSTRUCTION JOINT AT MID- SPAN.
F. IN SLAB ON METAL DECK CONSTRUCTION, PROVIDE
CONSTRUCTION JOINT AT MID-SPAN OF DECK AND MID-WAY
BETWEEN GIRDERS.
12. FINISHES:
A. ACI 117, SURFACES OF INTERIOR SLABS ON GRADE ARE TO BE
FINISHED TO THE FOLLOWING TOLERANCES: FLOOR FLATNESS F(f)= 30 AND LEVELNESS F(l)=20 UNLESS NOTED OTHERWISE IN
SPECIFICATIONS.
B. TYPICAL INTERIOR FLOOR AREAS TO RECEIVE CARPET, RESILIENT
FLOOR COVERING, OR TO REMAIN EXPOSED - TROWELED FINISH.
C. INTERIOR FLOOR AREAS TO RECEIVE QUARRY TILE OR CERAMIC
TILE - FLOATED FINISH.
D. EXTERIOR SLABS - BROOM FINISH.
E. SEE ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF
SPECIAL FINISHES OR TREATMENTS OF CONCRETE.
13. CURING:
A. TO COMMENCE IMMEDIATELY AFTER CONCRETE PLACEMENT AND
CONTINUE FOR AT LEAST 7 DAYS. DO NOT ALLOW CURING TO BE
DELAYED OVERNIGHT.
B. INTERIOR SLABS TO RECEIVE QUARRY TILE OR CERAMIC TILE ARE
TO BE MOIST-CURED WITHOUT THE USE OF A CURING COMPOUND.
C. ALL OTHER SLABS MAY BE EITHER MOIST-CURED OR RECEIVE AN
APPLICATION OF CURING COMPOUND.
14. MISCELLANEOUS:
A. PROVIDE CORROSION RESISTANT ACCESSORIES SUCH AS GRAY
PLASTIC CHAIRS IN ALL EXPOSED CONCRETE CONSTRUCTION.
PRECAST CONCRETE CUBES OR SAND PLATE CHAIRS SHALL BE
USED FOR THE SUPPORT OF THE REINFORCING ON GRADE.
CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED.
B. 3/4" CHAMFER FOR EXPOSED EDGES OF CONCRETE UNO.
C. CONCRETE SLABS SHALL BEAR A MINIMUM OF 4" ON MASONRY
WALLS, UNO. CONCRETE BEAMS SHALL BEAR A MINIMUM OF 8" ON
MASONRY WALLS, UNLESS NOTED OTHERWISE.
D. COORDINATE WITH ALL TRADES INVOLVED FOR THE REQUIRED SIZE
AND LOCATION OF ALL ANCHORS, SLEEVES, PADS, DEPRESSIONS,
OPENINGS AND EMBEDS.
E. BOND BREAKER MATERIAL SHALL BE 30 POUND FELT PAPER.
F. GROUT UNDER BEARING PLATES, SETTING PLATES AND COLUMN
BASE PLATES SHALL BE NON- SHRINKING TYPE. IT SHALL BE ONLY
INSTALLED AFTER THE STEEL IS PLUMB.
G. CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1/2 HOUR
AFTER WATER HAS BEEN ADDED TO THE CEMENT AND
AGGREGATES, ADDITION OF WATER TO THE MIX AT THE PROJECT
SITE WILL NOT BE PERMITTED. ALL WATER MUST BE ADDED AT THE
BATCH PLANT. SLUMP MAY BE ADJUSTED ONLY THROUGH THE USE
OF ADDITIONAL WATER REDUCING ADMIXTURE OR HIGH RANGE
WATER REDUCING ADMIXTURE.
MECH'L, ELEC'L, PLUMBING, FIRE PROTECTION & OTHER SUSPENDED ITEM:
1. SUPPORT ROOF TOP MECHANICAL EQUIPMENT ON STEEL FRAMES UNO.
MECHANICAL CONTRACTOR MUST SUPPLY SIZES, LOCATIONS AND
OPENING REQUIREMENTS TO THE STEEL FABRICATOR PRIOR TO
FABRICATION. DEVIATIONS AND/OR MODIFICATIONS TO THE SUPPORTING
STRUCTURE AFTER FABRICATION AND/OR ERECTION HAVE COMMENCED
SHALL BE THE RESPONSIBILITY OF THE SPECIFIED EQUIPMENT SUPPLIER AT
NO ADDITIONAL COST TO THE STEEL FABRICATOR, OWNER OR
CONSTRUCTION MANAGER.
2. THE STRUCTURE IN THE VICINITY OF LOADS IN EXCESS OF 400 POUNDS
SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER, PRIOR TO
INSTALLATION.
3. SUPPORT OF CONDUIT, SPRINKLER, HVAC OR PLUMBING PIPING SHALL BE
DISTRIBUTED SO AS NOT TO EXCEED THE UNIFORM LOADS INDICATED ON
THE DRAWINGS. SUPPORT PIPING FROM ROLLED BEAMS OR CHANNELS
FROM ANY LOCATION FROM EITHER TOP OR BOTTOM FLANGES. SUPPORT
ITEMS FROM OPEN WEB JOISTS OR WF MEMBERS FROM THE TOP CHORD
WHENEVER POSSIBLE. SUPPORT FROM TOP OR BOTTOM CHORDS OF
JOISTS SHALL ONLY BE PERMITTED WITHIN 6" OF A PANEL POINT.
RESULTING SINGLE HANGING LOAD ON A JOIST SHALL NOT EXCEED 300
POUNDS FOR A K-SERIES JOIST. MORE THAN TWO 300 POUND POINT LOADS
ON A K-SERIES JOIST IS STRICTLY PROHIBITED. STAGGER HANGERS AND
SUPPORTS FROM THE STRUCTURE SO AS TO DISTRIBUTE THE LOADS
UNIFORMLY ACROSS STRUCTURAL MEMBERS. HANGERS FROM METAL
ROOF DECK ARE STRICTLY PROHIBITED. DEVIATIONS FROM THE ABOVE
CRITERIA SHALL BE REMEDIED BY THE INSTALLING CONTRACTOR.
4. CONNECTIONS TO SUPPORTING STRUCTURAL MEMBERS, WHETHER NEW
OR EXISTING CONSTRUCTION, SHALL BE CLAMPING DEVICE WHICH DO NOT
DAMAGE OR DEFORM THE STRUCTURAL ELEMENTS. WELDING TO OR
DRILLING HOLES IN STRUCTURAL MEMBERS IS NOT PERMITTED WITHOUT
PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. IT IS THE
RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO LOCATE AND
DISTRIBUTE HANGING LOADS AS REQUIRED SO AS TO NOT EXCEED THE
LOAD CARRYING CAPACITY OF THE MEMBER.
5. TRAPEZING IS PERMITTED FOR MULTIPLE PIPE OR CONDUIT RUNS. LOADS
FROM TRAPEZE HANGERS SHALL BE AS PREVIOUSLY NOTED FOR
SUPPORTS FROM JOIST ELEMENTS. TRAPEZING IS NOT PERMITTED FOR
PIPING AND/OR CONDUIT GREATER THAN 3" IN DIAMETER.
6. THE APPROPRIATE INSTALLING CONTRACTOR IS RESPONSIBLE FOR
DETERMINING LOADS IMPOSED BY THE INSTALLED ITEMS. STAGGER
HANGERS AND SUPPORTS FROM THE STRUCTURE SO AS TO DISTRIBUTE
THE LOADS UNIFORMLY ACROSS STRUCTURAL MEMBERS.
7. WHERE 6" OR GREATER DIAMETER PIPES ARE PERPENDICULAR TO THE
JOISTS, PROVIDE HANGER SUPPORTS FROM EVERY JOIST WITHIN TWELVE
FEET OF THE END OF THE JOIST. STAGGER HANGERS TO DISTRIBUTE THE
LOAD UNIFORMLY ACROSS THE STRUCTURE.
8. WHERE 6" OR GREATER DIAMETER PIPE ARE PARALLEL TO THE JOISTS,
CENTER THE PIPE AND HANG THE PIPE FROM TWO JOISTS.
9. WHERE SUPPORT FROM JOISTS AT LOCATIONS OTHER THAN AT A PANEL
POINT IS NOT POSSIBLE, ADDITIONAL WEB REINFORCING IS REQUIRED.
REFER TO THE JOIST SUPPLIER AND/OR TYPICAL DETAIL INDICATED ON THE
PLANS. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO
COORDINATE THE LOCATIONS WITH THE STRUCTURAL STEEL FABRICATOR
AND/OR ERECTOR PRIOR TO INSTALLATION.
10. CONTRACTORS INSTALLING MEP & FP SYSTEMS SHALL COORDINATE
ROUTING PRIOR TO INSTALLATION SO AS TO DISTRIBUTE THE LOADING TO
THE STRUCTURE UNIFORMLY. DO NOT HANG ALL SYSTEMS FROM THE
SAME FRAMING MEMBER.
11. ALL HANGERS, WIRES, RODS ETC. FOR SUSPENDED ITEMS SUCH AS PIPING,
CONDUIT, DUCT WORK, FIRE PROTECTION, SUSPENDED CEILINGS,
TECHNOLOGY, ETC. SHALL BE INSTALLED FROM MAIN STRUCTURAL
MEMBERS. HANGERS ATTACHED TO METAL ROOF DECK, JOIST BRIDGING
OR FROM OTHER NON-STRUCTURAL SYSTEMS IS STRICTLY PROHIBITED.
2a
2a a a
ROOF PLAN
WALL ELEVATION
h 45 5 z
3 3
1 1
3 3 h a aa a a: END ZONE WIDTH IN FEET = 10 PERCENT OF BUILDING LEAST HORIZONTAL DIMENSION OR 0.4h WHICHEVER IS SMALLER, BUT NOT LESS THAN EITHER 4% OF LEAST
HORIZONTAL DIMENSION OR 3 FEET.
h: MEAN ROOF HEIGHT IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR
EAVE ANGLES < 10°
z: HEIGHT ABOVE GROUND IN FEET
CASE A: WINDWARD PARAPET CASE B: LEEWARD PARAPET
1111 Superior Avenue, Suite 2100 | Cleveland, OH 44114
(216) 861-2020 www.osborn-eng.com
C
IT
Y O
F C
LE
V E
LA
N D
SHEET NO:
CHECKED BY:
DESIGNED BY:
SCALE:
DELINEATED BY:
PROJECT NAME:
D E
P A
R T M
E N
T O
F P
U B
L
IC
W O
R K
S
C it y o f C le ve la n d
M a yo r' s O ff ic e o f C a p it a l P ro je c ts
D iv is io n o f A rc h it e c tu re
C le ve la n d
C it y H a ll
L a k e si d e A ve n u e
R o o m
A C le ve la n d
-1
P h o n e
-2 x:
-4 a n d S it e
D e ve lo p m e n t
TITLE:
h u ro n r o a d e a s t s u it…
This is the start of the file's text. The full file is on GovTribe.