These are bid documents for a construction project at Mare Island Naval Cemetery in Vallejo, California (Project 18181). The project involves site improvements including irrigation system installation, electrical infrastructure, technology/security systems, and structural work including concrete footings and foundations. The documents are dated May 4, 2026, and are issued by the U.S. Department of Veterans Affairs, Office of Design and Construction Services.
The bid documents include comprehensive construction drawings and specifications covering: concrete foundation design with 4000 psi compressive strength requirements and detailed reinforcement schedules; landscape irrigation system with 1,911 linear feet of mainline and 3,967 linear feet of lateral PVC piping, including pump station specifications (200 GPM @ 105 PSI capacity), valve schedules, and controller systems; electrical infrastructure with 240V single-phase service, panel schedules, and site lighting; and technology/security systems featuring six exterior-mounted surveillance cameras (360-degree coverage), underground fiber optic and copper conduit routing, telecommunications handhole installation, and equipment specifications for video management and monitoring. The project also includes general construction notes requiring compliance with the 2024 International Building Code, coordination with mechanical and electrical contractors, shop drawing submissions, and field verification of utilities. Consultant firms engaged include Terracon (geotechnical), OCMI (cost estimating), EC Design (irrigation), and Architectural Resources Group (conservator). No specific bid due date, contract type, set-asides, or pricing terms are stated in the provided documents.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL COMPLY WITH THE 2024 INTERNATIONAL BUILDING CODE, AS
APPROVED BY THE STATE OF CALIFORNIA / CITY OF VALLEJO.
2. REFERENCE STANDARDS: UNLESS OTHERWISE NOTED (U.O.N.), ALL
STANDARDS SHALL BE CURRENT EDITION, WITH LATEST ADDENDA, IF
APPLICABLE.
3. THE CONTRACTOR SHALL VERIFY ALL CONTRACT DOCUMENTS, SITE
ELEVATIONS, DIMENSIONS AND CONDITIONS PRIOR TO STARTING WORK AND
SHALL NOTIFY THE ARCHITECT/ ENGINEER OF ANY DISCREPANCIES OR
INCONSISTENCIES.
4. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL
NOTES.
5. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT
THE FINISHED STRUCTURE. UNLESS OTHERWISE INDICATED, THEY DO NOT
INDICATE THE MEANS OR METHOD OF CONSTRUCTION. TEMPORARY BRACING
AND SHORING AGAINST WIND AND ERECTION CONDITIONS DURING
CONSTRUCTION OF THE BUILDING, SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE
PROTECTION OF THE STRUCTURE DURING ALL PHASES OF DEMOLITION,
CONSTRUCTION, AND INSTALLATION.
6. NO AREA OF THE STRUCTURE SHALL BE LOADED WITH CONSTRUCTION
MATERIALS OR EQUIPMENT THAT EXCEEDS FINAL DESIGN CRITERIA.
7. VERIFY LOCATION OF BOX OUTS AND OPENINGS WITH MECHANICAL
CONTRACTORS. OPENING SIZES AND LOCATIONS SHOWN FOR PIPES, DUCTS
ETC. ARE FOR GENERAL INFORMATION ONLY AND SHALL BE VERIFIED WITH THE
MECHANICAL CONTRACTOR BEFORE COMMENCING THE WORK.
8. IF MECHANICAL AND ELECTRICAL EQUIPMENT SIZES, WEIGHTS, OR LOCATIONS
DO NOT COINCIDE WITH EQUIPMENT SHOWN ON PLANS, COORDINATE
ADJUSTMENTS WITH THE STRUCTURAL ENGINEER.
9. HOLES, PIPES, SLEEVES, ETC. NOT SHOWN ON THE DRAWINGS MUST BE
APPROVED BY THE STRUCTURAL ENGINEER BEFORE PLACEMENT THROUGH
STRUCTURAL MEMBERS.
10. CONTRACTOR SHALL PROVIDE A CAST-IN SLEEVE FOR ALL HORIZONTAL
ELEMENTS THAT EXTEND THROUGH FOOTING. IE: DRAIN TILE, ELECTRICAL
CONDUIT, MECHANICAL PIPING, ETC. ALL SLEEVES SHALL BE COORDINATED
WITH ARCHITECT/ENGINEER.
11. SHOP DRAWINGS PREPARED BY SUPPLIERS, SUBCONTRACTORS, ETC., SHALL
BE DIMENSIONED, REVIEWED, COORDINATED, AND SIGNED/ STAMPED BY THE
GENERAL CONTRACTOR PRIOR TO SUBMITTING TO THE STRUCTURAL
ENGINEER.
12. FABRICATOR SHALL CLEARLY NOTE CHANGES MADE IN THE SHOP DRAWINGS
WHICH DO NOT COMPLY WITH THE CONTRACT DOCUMENTS. REVIEWED
APPROVAL SHOP DRAWINGS SHOWING ENGINEERS COMMENTS ACCOMPANIED
WITH RECORD SET SHOP SHOP DRAWINGS, SHALL BE AVAILABLE FOR
REFERENCE AT THE CONSTRUCTION SITE.
13. CONCRETE ANCHORS SHALL BE SIMPSON 'TITEN HD" SCREW ANCHORS OR
EQUIVALENT (U.O.N.). INSTALL ANCHORS USING THE MANUFACTURER'S
RECOMMENDATIONS.
FOUNDATION NOTES:
1. FOOTING ELEVATIONS ARE TO TOP OF FOOTING (T.O. FTG.), UNLESS OTHERWISE
NOTED.
2. FOOTINGS ARE DESIGNED FOR A MINIMUM NET ALLOWABLE SOIL BEARING
PRESSURE OF1500 psf FOR CONTINUOUS AND 1500 psf FOR PAD FOOTINGS.
FOUNDATION DESIGN COMPLIES W/ GEOTECHNICAL REPORT DATED: MAY 12, 2025
BY TERRACON
3. FOOTINGS SHALL BEAR ON NATURAL UNDISTURBED SOIL OR ENGINEERED FILL.
SOILS SHALL BE OBSERVED AND APPROVED BY A GEOTECHNICAL ENGINEER
PRIOR TO PLACEMENT OF FOOTING CONCRETE. IF NATURAL UNDISTURBED SOILS
ARE NOT ENCOUNTERED AND/OR INADEQUATE SOILS ARE NOTED AT FOOTING
BEARING LEVEL, ARCHITECT/ENGINEER SHALL BE NOTIFIED PRIOR TO
PROCEEDING WITH FURTHER WORK AT THOSE FOOTING LOCATIONS.
4. PROTECT FOOTINGS FROM THE ACTION OF WATER OR FREEZING.
5. FOOTINGS ARE CENTERED UNDER WALLS ABOVE - UNLESS OTHERWISE NOTED.
6. PRIOR TO PLACEMENT OF FOOTING CONCRETE, CLEAN FOOTING EXCAVATIONS
OF SNOW, WATER AND DEBRIS.
7. FOOTINGS MAY NOT BE EARTH FORMED.
EXCAVATION & BACKFILL NOTES:
1. EXCAVATION AND BACKFILL SHALL BE EXECUTED IN ACCORDANCE WITH THE
PROJECT SPECIFICATIONS.
2. BACKFILL, & COMPACTION SHALL BE INSPECTED AND CERTIFIED BY A LICENSED
GEOTECHNICAL ENGINEER. REPORTS ARE TO BE SUBMITTED TO THE
ARCHITECT/ ENGINEER.
3. FOOTING EXCAVATIONS SHALL BE EXCAVATED TO PROPER LINE AND LEVEL TO
ENSURE MINIMUM CONCRETE COVER OF FOOTING REINFORCEMENT FOR
FOOTING DEPTH.
4. BACKFILL SHALL BE COMPACTED BY MECHANICAL MEANS. FLOODING OR
WATER INUNDATION SHALL NOT BE PERMITTED.
5. BACKFILL SHALL BE PLACED IN ALTERNATING LIFTS ON EACH SIDE OF THE
FOUNDATION WALLS TO MAINTAIN STABILITY OF THE FOUNDATION WALLS.
6. BACKFILL SHALL NOT BE PLACED AGAINST BASEMENT FOUNDATION WALLS
UNLESS WALLS ARE ADEQUATELY BRACED TOP AND BOTTOM. FINAL WALL
BRACING IS BASEMENT SLAB OR ENGINEERED BACKFILL AND 1ST FLOOR
STRUCTURE. IF THESE ELEMENTS ARE NOT IN PLACE AT TIME OF BACKFILL,
CONTRACTOR SHALL PROVIDE AN ENGINEERED, TEMPORARY BRACING
SYSTEM. THE TEMPORARY BRACING SYSTEM PROPOSED SHALL BE SUBMITTED
TO THE ARCHITECT/ ENGINEER FOR REVIEW PRIOR TO BACKFILLING.
CONCRETE NOTES:
1. CONCRETE CONSTRUCTION SHALL CONFORM TO AMERICAN CONCRETE
INSTITUTE (ACI) CODES AND SPECIFICATIONS, LATEST EDITION. ACI 301
"SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI 315 "DETAILS &
DETAILING OF CONCRETE REINFORCEMENT" ACI 318 "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE".
2. CONCRETE MIX DESIGN SHALL BE BY AN INDEPENDENT TESTING
LABORATORY.
3. CAST-IN-PLACE CONCRETE SHALL BE SUBJECT TO TESTING BY AN
INDEPENDENT TESTING LABORATORY. SEE PROJECT SPECIFICATIONS
FOR REQUIREMENTS.
4. NON WELDED REINFORCING STEEL SHALL BE GRADE 60 DEFORMED,
BILLET-STEEL, ASTM A615, U.O.N. ALL WELDED WIRE FABRIC (WWF)
SHALL BE PLAIN, ASTM A185.
5. WELDED REINFORCING STEEL SHALL BE GRADE 60, LOW CARBON, ASTM
A706.
6. PROVIDE EXTRA REINFORCEMENT AROUND ALL OPENINGS GREATER
THAN 12" SQUARE OR 12" IN DIAMETER, INCLUDING DOOR OPENINGS, IN
CONCRETE WALLS & SLABS. PROVIDE 2 - #5 BARS @ 3" O.C., ON EACH
SIDE OF THE OPENING EXTENDING 24" BEYOND THE CORNER OF THE
OPENING & 2 - #5 BARS AT 3" O.C. BY 3'-0" LONG DIAGONAL BARS AT EACH
CORNER. PLACE DIAGONAL BARS CENTERED ON CORNER @ 2" CLEAR
OF CORNER. ADDITIONAL REINFORCEMENT SHALL BE PROVIDED AT EACH
LAYER OF REINFORCING.
7. REINFORCING STEEL SHALL BE BENT, SPLICED, AND PLACED IN
ACCORDANCE WITH THE ACI 301 (LATEST EDITION).
8. PROVIDE ADEQUATE SUPPORT BARS AND ACCESSORIES TO HOLD
REINFORCING BARS FIRMLY IN PLACE TO SPECIFIED COVERAGES.
9. CAST DOWELS, WITH STD 90 DEGREE HOOK, IN FOOTINGS FOR
CONCRETE PIERS AND WALLS ABOVE. DOWELS SHALL BE THE SAME SIZE
AND NUMBER AS THE VERTICAL REINFORCING. (U.O.N.)
10. CONCRETE MIX DESIGNS REQUIREMENTS: - AGGREGATES SHALL
CONFORM TO ASTM C33. - CONCRETE EXPOSED TO FREEZE THAW SHALL
HAVE 4.5%-7.5% AIR. - WATER/CEMENT RATIO 0.55 MAX. FOR FOOTINGS
AND WALLS, 0.5 MAX. FOR SLABS - NO FLY ASH IN EXPOSED SLABS, 0.25
MAX. FLY ASH/CEMENT RATIO IN ALL OTHER APPLICATIONS - WATER
PROOFING ADMIXTURE ADD FOR EXTERIOR EXPOSED CONCRETE.
11 INJECTION ADHESIVE ANCHORS SHALL BE SIMPSON "SET-3G" USING
STANDARD 36 KSI THREADED RODS (U.O.N.). SEE SPECIFICATIONS FOR
USAGE. INSTALL ANCHORS IN STRUCTURAL CONFORMANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
CAST-IN-PLACE CONCRETE COMPRESSIVE STREGNTHS
FOOTINGS 4000 psi.
EXTERIOR FOUNDATION WALLS 4000 psi.
PIERS 4000 psi.
REINFORCING CLEAR CONCRETE COVER
CONCRETE ON SOIL 3"
SLABS ON GRADE MIDHEIGHT
FORMED WALLS & STRUCTURAL SLABS EXPOSED TO EARTH OR
WEATHER: #6 THRU #18
2"
FORMED WALLS & STRUCTURAL SLABS EXPOSED TO EARTH OR
WEATHER: #5 OR SMALLER
1 1/2"
FORMED WALLS & STRUCTURAL SLABS NOT EXPOSED TO EARTH OR
WEATHER: #11 AND SMALLER
3/4"
BEAMS AND COLUMNS (COVER TO STIRRUPS OR TIES) 1 1/2"
CONC. REINFORCING BAR LAP SPLICE
SCHEDULE
BAR SIZE
f'c = 3000 psi.
f'c = 4000 psi.
f'c = 5000 psi.
CLASS
"B"
CLASS
"B"
CLASS
"B"
#3 22" 20" 18"
#4 30" 26" 22"
#5 36" 32" 28"
#6 44" 38" 34"
#7 64" 54" 50"
#8 72" 62" 56"
#9 82" 70" 64"
#10 92" 80" 70"
#11 102" 88" 78"
BAR LAP SCHEDULE NOTES:
A. REINFORCING BAR LAP SPLICE SCHEDULE APPLIES TO UNCOATED, GRADE 60
REINFORCING BAR NORMAL WEIGHT CONCRETE.
B. PROVIDE CLASS "B" LAP UNLESS OTHERWISE NOTED.
C. FOR EPOXY COATED BAR, MULTIPLY THE NOTED LENGTHS BY 1.5.
D. FOR LIGHT WEIGHT CONCRETE, MULTIPLY THE NOTED LENGTHS BY 1.3.
E. MAXIMUM SPACING OF BARS BEING LAPPED IS ONE FIFTH THE LAP SPLICE
LENGTH, NOT TO EXCEED 6".
F. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE
PLACED BELOW HORIZONTAL REINFORCEMENT.FOR TOP BARS, MULTIPLY THE
NOTED LENGTHS BY 1.3.
ABBREVIATIONS & SYMBOLS:
+/- PLUS OR MINUS
@ AT
A.B. ANCHOR BOLT
A.P.A. AMERICAN PLYWOOD
ASSOCIATION
A.S.T.M. AMERICAN SOCIETY OF TESTING
MATERIALS
ARCH. ARCHITECTURAL
B.B. BOND BEAM
B.O. BOTTOM OF
BLK. BLOCK
BM. BEAM
BOT. BOTTOM
BRG. BEARING
C CHANNEL
C.M.U. CONCRETE MASONRY UNIT
CCJ CONSTRUCTION CONTROL JOINT
CJ CONTROL JOINT
CL. CENTER LINE
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
D.L. DEAD LOAD
D.T. DOUBLE TEE / DRAIN TILE
DBL. DOUBLE
DIA. DIAMETER
DIM. DIMENSION
DWL. DOWEL
E.F. EACH FACE
E.J. EXPANSION JOINT
E.W. EACH WAY
EA. EACH
EL. ELEVATION
ELEV. ELEVATOR
EQ. EQUAL
EX. EXISTING
EXC. EXCAVATION
EXP. EXPANSION
F.D. FLOOR DRAIN
FDN. FOUNDATION
FT. FEET
FTG. FOOTING
G.C. GENERAL CONTRACTOR
G.T. GIRDER TRUSS
GA. GAUGE
GALV. GALVANIZE
HC. HOLLOWCORE
HORIZ. HORIZONTAL
HSS HOLLOW STRUCTURAL SECTION
I.F. INSIDE FACE
INT. INTERIOR
JST. JOIST
KLF. KIPS PER LINEAR FOOT
KSI. KIPS PER SQUARE INCH
L ANGLE
LB LEDGER BEAM
LL LIVE LOAD / DOUBLE ANGLE
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LWC LIGHT WEIGHT CONCRETE
M.C. MECHANICAL CONTRACTOR
MAS. MASONRY
MAX. MAXIMUM
MECH. MECHANICAL
MFG. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MTL. METAL
N. NORTH
N.T.S. NOT TO SCALE
NS. NON-SHRINK
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OUTSIDE FACE
O.H. OVERHEAD
OPNG. OPENING
ORIG. ORIGINAL
P.A.F. POWDER ACTUATED FASTENER
P.C. PRECAST CONCRETE
PART. PARTITION
PL. PLATE
PLF POUNDS PER LINEAR FOOT
PNL. PANEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PW PLYWOOD
R. OR
RAD.
RADIUS
R.D. ROOF DRAIN
REINF. REINFORCING
REQD. REQUIRED
S.A. STUD ANCHOR
S.B. SOIL BORING
S.D. SEE DETAIL
S.D.L. SUPERIMPOSED DEAD LOAD
S.E.R. STRUCTURAL ENGINEER OF
RECORD
S.L. SNOW LOAD
S.L.L. SUPERIMPOSED LIVE LOAD
S.S. STAINLESS STEEL
SCHED. SCHEDULE
SHT. SHEET
SIM. SIMILAR
SPA. SPACING / SPACES
SPECS. SPECIFICATIONS
SQ. SQUARE
STD. STANDARD
STL. STEEL
T & B TOP & BOTTOM
T & G TONGUE & GROOVE
T.O. TOP OF
T.O.B. TOP OF BEAM
T.O.J. TOP OF JOIST
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
T.S.E. TOP OF STEEL ELEVATION
TEMP. TEMPORARY
THK. THICK / THICKENED
TRANS. TRANSVERSE
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V. / VER. VERIFY
VERT. VERTICAL
W.L. WIND LOAD
W/ WITH
W/O WITH OUT
WD. WOOD
WTS. WEIGHTS
WWF WELDED WIRE FABRIC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18181
GEOTECHNICAL/HAZMAT/
ENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
Project Director
2026.05.04
BID DOCUMENTS
CONSERVATOR:
ARCHITECTURAL RESOURCES GROUP
PIER 9, THE EMBARCADERO SUITE 107
SAN FRANSISCO, CA 94111
415-421-1680
POINT OF CONTACT
JENNIFER PONT
C U s e rs \J
B u e rm a n n \D o c u m e n ts \1
M
A R
E I S
L A
N D
R
V T jb u e rm a n n S
R X
R
.r v t
/3
/2
:5
:0
A
M
NOTE SHEET
MAY 04, 2025 FY JB
S001
IMHOFF ROAD, VALLEJO, CA 94592
MARE ISLAND NAVAL CEMETERY
962-003
RESPONSE MODIFICATION FACTOR R = 1.5
SEISMIC DESIGN CATEGORY E
SITE CLASS D (DEFAULT)
DESIGN SPECTRAL RESPONSE Sd1 = 1.21 DESIGN SPECTRAL RESPONSE Sds = 1.61
MAPPED SPECTRAL RESPONSE S1 = 0.9
MAPPED SPECTRAL RESPONSE Ss = 2.33 SEISMIC IMPORTANT FACTOR le = 1
SEISMIC LOADS
IMPORTANCE FACTOR Iw = 1.0
POLE DIAMETER 12" TAPERED TO 4.4"
WIND EXPOSURE "C"
RISK CATEGORY II
ULTIMATE WIND SPEE (3 SECOND GUST) 110 MPH.
LATERAL LOADS
ASSUMED FLAG POLE WP 500 LB
DEAD LOADS:
14. DESIGN LOADS:
Revisions: Date:
T.O. PIER
EL. = SEE ARCH.
3.91°
/8
A
B 112' - 2 1/8"
C
33.63°
6' - 2"
7' - 8 5/8"
7' - 7 3/4"
20' - 11"
18' - 11"
37' - 11 3/8"
26' - 5 3/4"
29' - 6 1/4"
FC6
FC6
FC6
FC6
FC6
FC6
FC6
10"
10"
10"10"
4' - 1"
4' - 1 1"
26' - 11"
S301
S301
S
S
14' - 0"
43' - 0"
T.O. FTG.
EL. = 38' - 0"
T.O. FTG.
EL. = 36' - 0"
T.O. FTG.
EL. = 34' - 0"
24' - 0" S
T.O. FTG.
EL. = 32' - 6"
T.O. FTG.
EL. = 31' - 0"
CONCRETE APRON
SEE CIVIL
FLAG POLE BY
OTHERS
3 - #4 TIES
@ 3" O.C.
3' - 0"
A
S101
NOTE: COORDINATE WITH CIVIL FOR FINAL LOCATION OF FLAG POLE
CONC. PIER
SECTION "A"
12 - #6 VERTS. W/
#4 TIES @ 1'-0" O.C.
U.O.N.
GRID
GRID
" L
A P
1 1/2" CLR.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18181
GEOTECHNICAL/HAZMAT/
ENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
Project Director
2026.05.04
BID DOCUMENTS
CONSERVATOR:
ARCHITECTURAL RESOURCES GROUP
PIER 9, THE EMBARCADERO SUITE 107
SAN FRANSISCO, CA 94111
415-421-1680
POINT OF CONTACT
JENNIFER PONT
C U s e rs \J
B u e rm a n n \D o c u m e n ts \1
M
A R
E I S
L A
N D
R
V T jb u e rm a n n S
R X
R
.r v t
/3
/2
:5
:0
A
M
FOOTING & FOUNDATION PLAN
MAY 04, 2025 FY JB
S101
IMHOFF ROAD, VALLEJO, CA 94592
MARE ISLAND NAVAL CEMETERY
962-003
1. VERIFY ALL DIMENSIONS WITH CIVIL DRAWINGS.
2. SEE SHEET S001 FOR GENERAL STRUCTURAL NOTES.
3. FC/S/T# = FOOTING MARK - SEE FOOTING SCHEDULE ON THIS SHEET.
4. = STEPPED FOOTING LOCATION - S.D. 1/S301.
SHEET NOTES:
S
1/16" = 1'-0"
FOOTING & FOUNDATION PLAN
T.O. EXT. FOOTING EL. = 31' (CIVIL GRADING REF) @ GRID 1
Schedule - Footings
MARK WIDTH DEPTH
REINFORCING
COMMENTS
TRANSVERSE LONGITUDINAL
FC6 6'-0" CONT. 1'-4" #6 @ 1'-0" O.C. #5 @ 1'-0" O.C. T&B
FOOTING SCHEDULE NOTES:
1. T&B DESIGNATES REINFORCING STEEL TO BE AT TOP & BOTTOM OF FOOTING.
0 16' 32'8'
1/2" = 1'-0"
FLAG POLE FOUNDATION
T.O. FTG. EL. = 34' (CIVIL GRADING REF) @ GRID 2
T.O. WALL
(VARIES)
EL. = SEE CIVIL
T.O. GRADE
EL. = SEE CIVIL
T.O. GRADE
EL. = SEE CIVIL
T.O. WALL
(VARIES)
EL. = SEE CIVIL
3" CLR. - TYP.
SIZE & REINF.
SEE PLAN FOR
NOTE:
EXTEND ALL REINFORCING THRU CORNER - LAP & TIE.
NOTE:
IF WALL SURFACE IS SOIL LOADED EXTEND HORIZONTAL BARS TO OPPOSITE FACE & PROVIDE STANDARD HOOK.
SIZE & REINF.
SEE PLAN FOR
3 - #4 VERT. W/ DWL.
TO MATCH @ FOOTING.
CORNER BARS TO
MATCH SIZE &
SPACING OF HORIZ.
WALL REINF.
S E
E S
C H
E D
LA
P
S P
LI
C
E D
1 1/2" CLR. - TYP.
SIZE & REINF.
SEE PLAN FOR
CORNER BARS
TO MATCH SIZE
& SPACING OF
HORIZ. WALL
REINF.
1 1/2" CLR. - U.O.N.
SIZE & REINF.
SEE PLAN FOR
VERT. W/ DWL. TO
MATCH @ FOOTING.
CORNER BARS TO
MATCH SIZE &
SPACING OF HORIZ.
WALL REINF.
1 1/2" CLR. - U.O.N.
S E
E S
C H
E D
LA
P
S P
LI
C
E
S E
E S
C H
E D
LA
P
S P
LI
C
E
NOTE:
CONST. JOINT SHOWN MAY BE OMITTED @ CONTRACTOR'S OPTION.
SIZE & REINF.
SEE PLAN FOR
2" x 4" x 6" LONG.
VERT. KEYWAY
EVENLY SPACED
BETWEEN HORIZ.
REINF. SPACING
DWL. W/ STANDARD
HOOK TO MATCH
SIZE & SPACING OF
HORIZ. REINFORCING
2" CLR. - TYP.
S E
E S
C H
E D
LA
P
S P
LI
C
E
2" x 6" x 6" LONG.
VERT. KEYWAY
EVENLY SPACED
BETWEEN HORIZ.
REINF. SPACING
DWL. W/ STANDARD
HOOK TO MATCH
SIZE & SPACING OF
HORIZ. REINFORCING
SIZE & REINF.
SEE PLAN FOR
2" CLR. - TYP.
S E
E S
C H
E D
LA
P
S P
LI
C
E
NOTE:
JOINT MAXIMUM SPACING 40'-0". SPACING MAY BE INCREASED TO 80'-0"
IF WALL IS BACKFILLED INTERIOR SIDE FOR FULL HEIGHT OR 120'-0" IF
WALL IS BACKFILLED ON BOTH SIDES FOR FULL HEIGHT.
1"
1/2"
S
IZ
E
R E
IN
F
S E
E P
LA
N
F O
R
1 1/2"
6" 6"
SEE SCHED.
LAP SPLICE3" CLR.VERT. CAULK JOIST @
EACH FACE
2" x 6" x 6" LONG. VERT. KEYWAY (2" x 4" x 6" @ 8" WALL) EVENLY
SPACED BETWEEN HORIZ. REINF.
SPACING. KEYWAY CONT. WHERE
WATERSTOP IS REQUIRED
VERT. CAULK
VERT. ROD STOCK
WATERSTOP
WHERE
REQUIRED
#6 @ 12" O.C. VERT.
EACH FACE
#5 @ 1'-0" O.C. HORIZ.
EACH FACE
SEE PLAN FOR
FOOTING SIZE,
REINF. & ELEV.
DWL. TO MATCH
EACH VERT.
3" CLR. - TYP.
2' - 0" 10" 3' - 2"
1 1/2" CLR.
2" CLR.
#6 @ 12" O.C. TOP &
BOT.
#6 @ 12" O.C. VERT.
#6 @ 12" O.C. VERT.
SEE PLAN FOR
FOOTING SIZE,
REINF. & ELEV.
DWL. TO MATCH
EACH VERT.
3" CLR. - TYP.
2' - 8" 10" 2' - 6"
1 1/2" CLR.
2" CLR.
#6 @ 12" O.C. TOP &
BOT.
EX. GRADE
#5 @ 12" O.C. HORIZ.
EACH FACE
#5 @ 12" O.C. CONT.
TOP & BOT.
NOTE:
PROVIDE 12" GRAVEL LAYER BEHIND WALLS PER GEOTECHNICAL REPORT
2a U.O.N.
a
SEE PLAN
3" CLR. - TYP.
DEPTH 1'-0" MIN.
EQUAL TO FTG.
2a U.O.N.
NOTES:
1. SEE PLAN FOR FOOTING SIZE AND REINFORCING.
2. SLOPED OR STEPPED FOOTINGS SHALL BE CAST AS A UNIT.
3. STEPPED FOOTING LINES SHOWN ON PLAN ARE @ BOTTOM OF FOOTING.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18181
GEOTECHNICAL/HAZMAT/
ENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
Project Director
2026.05.04
BID DOCUMENTS
CONSERVATOR:
ARCHITECTURAL RESOURCES GROUP
PIER 9, THE EMBARCADERO SUITE 107
SAN FRANSISCO, CA 94111
415-421-1680
POINT OF CONTACT
JENNIFER PONT
C U s e rs \J
B u e rm a n n \D o c u m e n ts \1
M
A R
E I S
L A
N D
R
V T jb u e rm a n n S
R X
R
.r v t
/3
/2
:5
:0
A
M
FOOTING & FOUNDATION DETAILS
MAY 04, 2025 FY JB
S301
IMHOFF ROAD, VALLEJO, CA 94592
MARE ISLAND NAVAL CEMETERY
962-003
1/2" = 1'-0"S301
1 FOOTING CORNER REINF. DETAIL
1/2" = 1'-0"S301
2 WALL CORNER REINF. DETAIL
1/2" = 1'-0"S301
3 WALL INTERSECTION DETAIL
1/2" = 1'-0"S301
4 WALL CONSTRUCTION JOINT DETAIL
1/2" = 1'-0"S301
5 RETAINING WALL DETAIL
1/2" = 1'-0"S301
6 RETAINING WALL DETAIL
1/2" = 1'-0"S301
7 STEPPED FOOTING DETAIL
16"
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
C
FW
FW
FW
COORDINATE LOCATION AND
POWER WITH CIVIL DRAWINGS
BOOSTER PUMP
RAIN SENSOR ON 5'-0" POLE
P
S
C-1 54.22"
C-1
C-2 48.82"
C-2
C-3 68.42"
C-3
C-4 68.42"
C-4
C-5 51.32"
C-5
C-6 51.32"
C-6
C-7 20.11"
C-7
C-8 20.11"
C-8 C-9
20.11" C-9
C-10 80.62"
C-10
C-11 151"
C-11
C-12 68.42"
C-12
C-13 68.42"
C-13
C-14 141"C-14
C-15 562"
C-15
C-16 68.42"
C-16
C-17 12.51"
C-17
C-18 562"
C-18 C-20
562"
C-20
C-21 48.82"
C-21
C-22 111"
C-22
C-23 48.82"
C-23
3"
3"
3"
3"
3"
2"
4"
2"
4"
2"
4"
4"
2"
4"
4"
2"
2"
4"
4"
4"
2"
2"
2"
2"
4"
2"
4"
2"
4"
2"
1"
4"
2"
4"
2"11 2"
4"
2"
1"
1"
2"
4"
2"
FW
2"
4"
2"
2"
4"
2"
1"
2"
1"
C-19 10.51"
C-19
1"
3"
4"
2"
2"
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
1"
1"
1"
1"
4"
2"
4"
2"
1"
1" 1"
1"11 4"
1"
4"
1"
1"
1"
4"
1"
4"
1"
4"
3"3"
A
2"
1"
2"
2"
2"
2"
1"
1"
1"
3"
3"
3"
3"
4"
2"
1"
1"
1"
2"
2"
1"
1"
1"
1"
1"
2"
1"
2"
4.0
4.0
4.0
4.0
1. ALL POWER WIRE TAPS AND CONNECTIONS SHALL CONFORM TO WITH LOCAL AND STATE CODES
AND PERFORMED BY LICENSED ELECTRICIAN.
2. 24" LOOP OF WIRE LOCATED BELOW EACH ELECTRIC VALVE.
3. ALL WIRE SHALL HAVE ENOUGH SLACK AS TO ACCOMMODATE FOR EXPANSION AND/OR
CONTRACTION.
4. ALL WIRE TO BE UL APPROVED FOR DIRECT BURIAL.
1. ALL PRODUCT APPLICATIONS AND INSTALLATIONS MUST MEET MANUFACTURER'S REQUIREMENTS.
2. FLOW RATES THROUGH PVC PIPING NOT TO EXCEED MANUFACTURER'S RECOMMENDATIONS.
3. SPRINKLER SPACING BASED ON CURRENT SITE CONDITIONS. SOME NOZZLE/ARC ADJUSTMENTS
MAY BE REQUIRED IN THE FIELD.
4. PIPING AS SHOWN IS DIAGRAMMATIC IN NATURE. ALL PIPING TO BE LOCATED WITHIN OWNER'S
PROPERTY LINES.
5. CONTRACTOR IS RESPONSIBLE FOR PROPER OPERATION OF IRRIGATION SYSTEM. SYSTEM SHALL
NOT EXCEED MANUFACTURER'S RECOMMENDATIONS AND SHALL WATER ALL LANDSCAPED
AREAS NOTED. IRRIGATION PLAN IS INTENDED TO INCLUDE EVERYTHING NECESSARY TO THE
PROPER OPERATION OF SAID IRRIGATION SYSTEM. IF ADJUSTMENTS ARE REQUIRED,
CONTRACTOR SHALL MAKE ADJUSTMENTS FOR SAME.
6. IRRIGATION SPECIFICATIONS SHALL HAVE PRECEDENCE OVER IRRIGATION PLANS. ANY
DISCREPANCIES BETWEEN THESE TWO DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF
THE OWNERS REPRESENTATIVE BEFORE BID DUE DATE.
7. IT IS THE INTENT TO KEEP IRRIGATION WATER OFF OF ALL BUILDINGS, SIDEWALKS, SIGNS AND PARKING AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FIELD TUNE EACH SPRINKLER AS TO KEEPING IRRIGATION ADJUSTED TO LANDSCAPED AREAS ONLY. IT
WILL ALSO BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO SUPPLY THE OWNER
WITH AN OPERATING SCHEDULE THAT WORKS WITH EXISTING PLANS AND ANY FIELD
ADJUSTMENTS.
8. IT IS THE INTENT OF THE IRRIGATION DESIGN TO ACHIEVE HEAD TO HEAD COVERAGE IN ALL
LANDSCAPED AREAS AND TO MATCH SOIL AND PLANT MATERIAL WATERING NEEDS. IT WILL BE
THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO ADJUST FOR SAME.
9. IRRIGATION CONTRACTOR TO LOCATE VALVE BOXES AWAY FROM ROAD/CURB AND AWAY FROM
GRAVE SITES SO THEY ARE LESS VISUAL WHERE APPLICABLE.
10. IRRIGATION CONTRACTOR SHALL PROVIDE OWNERS REPRESENTATIVE WITH ALL SHOP
DRAWINGS AND SUBMITTALS OF PROPOSED IRRIGATION SYSTEM BEFORE INSTALLATION.
11. ALL PIPING SHALL BE INSTALLED A MINIMUM OF 3'-0" FROM EDGE OF CONCRETE CURBS, ETC.
1. ALL PIPING FITTINGS SHALL BE DUCTILE IRON TYPE ON MAIN LINE.
2. ALL SUB MAIN LINE PIPING FITTINGS SHALL BE JOINT RESTRAINED AT ALL CHANGES OF DIRECTION
- SEE DETAIL AND JOINT RESTRAINT NOTES.
3. LATERAL ZONES ARE 1" UNLESS NOTED.
DESIGN NOTES
ELECTRICAL NOTES:
PLUMBING NOTES:
1. CEMETERY HOURS ARE 8:00AM - 4:30PM. ALL WORK SHALL COMMENCE WITHIN THE CEMETERY
HOURS UNLESS EXPRESSLY AUTHORIZED BY CEMETERY DIRECTOR AND COR.
2. CONTRACTOR SHALL COORDINATE WITH CEMETERY DIRECTOR ON WORK SCHEDULE FOR THE
WEEK PRECEDING VETERAN'S DAY HOLIDAY. WORK AREAS WILL BE REQUIRED TO BE
SECURED, MADE SAFE, AND CLEARED OF ALL DEBRIS AND MATERIALS PRIOR TO VETERAN'S
DAY HOLIDAY TO FACILITATE CEMETERY OPERATIONS DURING VETERAN'S DAY EVENTS.
3. CONTRACTOR SHALL REPLACE IN KIND ANY AREAS DAMAGED OR REMOVED DUE TO
CONSTRUCTION TRAFFIC AND IRRIGATION INSTALLATION AT NO COST TO THE GOVERNMENT.
4. CONTRACTOR SHALL INSTALL EROSION CONTROL MEASURES AS NEEDED THROUGHOUT THE
PROJECT DURATION TO LIMIT EROSION AND PROTECT EXISTING FACILITIES.
5. PROTECT IN-SERVICE LANDSCAPE IRRIGATION INFRASTRUCTURE AND CONDUCT ALL WORK IN
A MANNER THAT DOES NOT INTERRUPT ANY LANDSCAPE IRRIGATION OPERATION OUTSIDE OF
THIS PROJECT LIMITS. THIS WILL INCLUDE REGULAR COORDINATION WITH GROUNDS STAFF,
CEMETERY DIRECTOR, AND COR TO ENSURE NORMAL OPERATIONS THROUGHOUT
CONSTRUCTION.
6. PROTECT IN PLACE ALL TREES TO REMAIN. TREES SHALL BE PROTECTED FROM DAMAGE
7. ANY IRRIGATION SYSTEM SHUTDOWNS, SHOULD THEY BE REQUIRED, ARE TO BE
COORDINATED WITH CEMETERY DIRECTOR AND COR 48 HOURS PRIOR TO SHUTDOWN.
8. ALL AREAS OF LANDSCAPE IRRIGATION EXPANSION INCLUDES CONSIDERATION FOR
WATER-EFFICIENT PRACTICES INCLUDING BUT NOT LIMITED TO PRESSURE REGULATION,
MATCHED APPLICATION RATES, TOPOGRAPHICAL CONSIDERATIONS AND SCHEDULING
PRACTICES.
9. SHOULD ANY ON-SITE ACTIVITY, INCIDENT, EMERGENCY, OR DISASTER RESULT IN EXPOSURE
AND/OR DAMAGE TO ANY REMAINS, CONTAINER FOR REMAINS (I.E., CASKET OR URN), OR
OUTER BURIAL CONTAINER, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CEMETERY
DIRECTOR, THE COR, AND/OR THE CO; TAKE IMMEDIATE STEPS TO PROTECT AND RENDER
SAFE ANY EXPOSED REMAINS; AND STOP ANY FURTHER WORK THAT COULD AFFECT THOSE
REMAINS OR GRAVE SITE UNTIL THE CEMETERY DIRECTOR PROVIDES THE CONTRACTOR
GUIDANCE REGARDING DISPOSITION OF THE REMAINS AND PERMISSION TO PROCEED.
10. ALL WORK SHALL BE COORDINATED WITH MARE ISLAND NATIONAL CEMETERY DIRECTOR TO
AIDE IN ACTIVE BURIAL SERVICE COORDINATION. THIS INCLUDES BUT IS NOT LIMITED TO
SECTION SEQUENCING, STAGING, AND WORK TAKING PLACE IMMEDIATELY ADJACENT TO
BURIAL OPERATIONS. CONSTRUCTION ACTIVITY SHALL HALT WHEN REQUESTED DUE TO
ONGOING BURIAL ACTIVITIES NEAR ACTIVE CONSTRUCTION SITES. IT IS ANTICIPATED TO HAVE
DAILY COORDINATION WITH CEMETERY DIRECTOR TO COORDINATE BURIAL OPERATIONS WITH
ACTIVE CONSTRUCTION.
11. ALL IRRIGATION COMPONENT LOCATIONS SHALL BE LOCATED/STAKED FROM THE DESIGN
INFORMATION BY A LICENSED SURVEYOR (DRAWING FILES AVAILABLE BY REQUEST), AND
AS-BUILT LOCATIONS SHALL BE REQUIRED AS WORK PROGRESSES (ESPECIALLY
UNDERGROUND PIPE BENDS) PRIOR TO CLOSING OF TRENCHES.
12. IRRIGATION IN EXISTING CEMETERIES SHALL REQUIRE MANDATORY PROBING PROTOCOL
IMPLEMENTED PRIOR TO ALL IRRIGATION PIPE PLACEMENT ACTIVITIES, AND DAILY
PRECONSTRUCTION PROGRESS MEETING TO REDUCE RISK.
ADDITIONAL PROJECT REQUIREMENTS:
NOTE: ALL QUANTITIES ARE FOR REFERENCE ONLY. CONTRACTOR RESPONSIBLE FOR ACTUAL COUNTS.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1806-5 SERIES STREAM 67 25
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS
RAIN BIRD 5006-PC 4.0 15 45 4.01 42'
RAIN BIRD 6504-PC, FC-SS 12 14 60 12.2 57'
RAIN BIRD 6504-PC, FC-SS 14 15 60 14 61'
RAIN BIRD 6504-PC, FC-SS 18 30 60 17.1 63'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
GRISWOLD DWS-PRV
WITH TORO TWO-WIRE DECODER 23
RAIN BIRD 44-LRC 10
RT/RW ISOLATION VALVE - LINE SIZED 8
BERMAND C30 2" AIR/VACUUM RELIEF VALVE 1
TORO DXI-SPED-TW LAGUNA CONTROLLER 1
TORO TRS 1
WATERTRONICS: WMBV-7000-7A-15-240-1-200-105
PRE-PACKAGED, UL LISTED, MARINE GRADE ALUMINUM,
SELF-ENCLOSED SYSTEM WITH SINGLE PUMP AND VFD.
FLOWS UP TO 200 GPM @ 105 PSI
FLOWER WATERING STATION 4
PAIGE 270-RCX RE-ENTERABLE CONNECTOR
WITH 36" GROUND PLATE, ROD AND GROUND
ENHANCEMENT MATERIALS OR AS PER MANUFACTURE'S
RECOMMENDATIONS
TORO DEC-SG-LINE SURGE PROTECTOR
WITH 36" GROUND PLATE, ROD AND GROUND
ENHANCEMENT MATERIALS OR AS PER MANUFACTURE'S
RECOMMENDATIONS
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 3,967 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1,911 LF
CST Q H F
4.0
A
C
S
P
FW
Valve Number
Valve Flow
Valve Size
Valve Callout
IRRIGATION SCHEDULE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\d es ig n pr oj ec ts
\m ar e is la nd n av al c em et er y\
- d ra w in gs
\m ar e is la nd n c irr ig at io n.
dw g ed it:
ch ris m er te n sa ve d:
4/
/2
:2
AM
p lo t:4
/3 0/
0:
A
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18181Date:
Office of Design and Construction
Services
MARE ISLAND NAVAL CEMETERY
962-003
MAY 4, 2026
IMHOFF ROAD, VALLEJO, CA, 94592
BID DOCUMENTS
GEOTECHNICAL/HAZMATENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
BID DOCUMENTS
2026.05.04
SCALE:1
SITE IRRIGATION PLAN
1" = 30'-0"
N 0 30' 60'
IR101
X
SITE IRRIGATION PLAN
CJM CJM
16"
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
NOTE: ALL QUANTITIES ARE FOR REFERENCE ONLY. CONTRACTOR RESPONSIBLE FOR ACTUAL COUNTS.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1806-5 SERIES STREAM 67 25
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS
RAIN BIRD 5006-PC 4.0 15 45 4.01 42'
RAIN BIRD 6504-PC, FC-SS 12 14 60 12.2 57'
RAIN BIRD 6504-PC, FC-SS 14 15 60 14 61'
RAIN BIRD 6504-PC, FC-SS 18 30 60 17.1 63'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
GRISWOLD DWS-PRV
WITH TORO TWO-WIRE DECODER 23
RAIN BIRD 44-LRC 10
RT/RW ISOLATION VALVE - LINE SIZED 8
BERMAND C30 2" AIR/VACUUM RELIEF VALVE 1
TORO DXI-SPED-TW LAGUNA CONTROLLER 1
TORO TRS 1
WATERTRONICS: WMBV-7000-7A-15-240-1-200-105
PRE-PACKAGED, UL LISTED, MARINE GRADE ALUMINUM,
SELF-ENCLOSED SYSTEM WITH SINGLE PUMP AND VFD.
FLOWS UP TO 200 GPM @ 105 PSI
FLOWER WATERING STATION 4
PAIGE 270-RCX RE-ENTERABLE CONNECTOR
WITH 36" GROUND PLATE, ROD AND GROUND
ENHANCEMENT MATERIALS OR AS PER MANUFACTURE'S
RECOMMENDATIONS
TORO DEC-SG-LINE SURGE PROTECTOR
WITH 36" GROUND PLATE, ROD AND GROUND
ENHANCEMENT MATERIALS OR AS PER MANUFACTURE'S
RECOMMENDATIONS
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 3,967 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1,911 LF
CST Q H F
4.0
A
C
S
P
FW
Valve Number
Valve Flow
Valve Size
Valve Callout
IRRIGATION SCHEDULE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\d es ig n pr oj ec ts
\m ar e is la nd n av al c em et er y\
- d ra w in gs
\m ar e is la nd n c irr ig at io n.
dw ch ris m er te d:
4/
/2
:2 lo t:4
/3 0/
0:
A
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18181Date:
Office of Design and Construction
Services
MARE ISLAND NAVAL CEMETERY
962-003
MAY 4, 2026
IMHOFF ROAD, VALLEJO, CA, 94592
BID DOCUMENTS
GEOTECHNICAL/HAZMATENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
BID DOCUMENTS
2026.05.04
SCALE:1
SITE IRRIGATION COVERAGE PLAN
1" = 30'-0"
N 0 30' 60'
IR102
X
SITE IRRIGATION COVERAGE PLAN
SCALE:
2 SLEEVING DETAIL
NONE
NOTE:
1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO
NOMINAL QUICK COUPLING VALVE INLET SIZE.
KEY HANDLE
KEY HANDLE TO CLEAR BOX
INSTALL AT HEIGHT TO ALLOW
INSTALLED HEIGHT TO CLEAR
FINISH GRADE
3/4-INCH WASHED GRAVEL
(LENGTH AS REQUIRED)
PVC SCH 80 NIPPLE
CONTINUOUS RUN OF BRICKS
QUICK-COUPLING VALVE:
3-INCH MINIMUM DEPTH OF
(AS SPECIFIED)
MANUFACTURED SWING JOINT
MAINLINE PIPE
STABILIZER
SCALE:
QUICK-COUPLING VALVE
WITH STABILIZER
NONE
OLDCASTLE/FIBRELYTE ROUND
POLYMER CONCRETE VALVE BOX
AND LID WITH MARKINGS
CLASS 200 IRRIGATION PVC PIPE
(SCRAP PVC
SLEEVE MARKER
PAST
CURB
LINE
AND COMPACTED)
(BACKFILLED
TRENCH
VERTICAL SCRAP PVC PAINTED BLUE
MARK ALL SLEEVES AT BOTH ENDS WITH
NOTE:
CAP
ENDS(WIRE SLEEVE - GRAY IN COLOR)
3" SCH. 80 PVC 1'
-6
1'-0"
PAINTED BLUE)
CLASS 200 PVC PIPE
SLEEVE (SIZED TWO PIPE
SIZES LARGER THAN
SLEEVED IRRIGATION PIPE
NOTED ON PLAN)
ALL ROAD CROSSINGS ARE SUBJECT
TO CITY FINAL LOCATION AND APPROVAL
BEFORE INSTALLATION - TYPICAL
(SEE PLAN FOR SIZE)
AS PER CODE
SCALE:
8 ELECTRIC VALVE AND VALVE BOX
NONE
SCALE:
3 ROTOR ASSEMBLY (FULL CIRCLE)
NONE SCALE:
ROTOR ASSEMBLY NEXT
TO HARDSCAPE (PART CIRCLE)
NONE
LATERAL TEE
LATERAL PIPE
MANUFACTURED SWING JOINT
POP UP ROTOR SPRINKLER
APPROVED BACKFILL
NOTE: INSTALL SPRINKLER HEAD BETWEEN
1/4" AND 1/2" BELOW TOP OF
SPRINKLER BLOCK (COLLAR)
CHRISTY CONCRETE SPRINKLER
BLOCK - INSTALL PER MANUFACTURER'S
RECOMMENDATIONS
2" GRAVEL BASE
EDGE OF CURB/LANSCAPE
7"
FINISH GRADE
MAINLINE PIPE
LOCATOR WIRE
SCALE:
1 IRRIGATION TRENCH DETAIL
NONE
36"
WARNING TAPE 12
SAND BEDDING
AND BACKFILL
LATERAL PIPE
4"
SCALE:
7 RESILIENT WEDGE GATE VALVE
NONE
FINISH GRADE
OLDCASTLE/FIBRELYTE JUMBO ROUND
POLYMER CONCRETE VALVE BOX AND
LID WITH MARKINGS
PVC SLEEVE
NOTCH PIPE TO FIT VALVE
RESILIENT WEDGE GATE VALVE
REFER TO PLAN FOR SIZE
3" MINIMUM DEPTH OF
3/4" WASHED GRAVEL
WIRE MESH
CONTINUOUS RUN OF BRICKS
RESTRAINED FLANGE ADAPTER
MAINTAIN A 36" DISTANCE FROM
CURB - COORDINATE ROUTING
WITH OTHER DISCIPLINES
REFER TO CIVIL DRAWINGS FOR
LOCATION - COORDINATE
ROUTING WITH OTHER
DISCIPLINES
HYDRANT POST - BY OTHERS
CONCRETE PAD - BY OTHERS
SCALE:
10 FLOWER WATER STATION ASSEMBLY
NONE
FINISHED GRADE
OLDCASTLE/FIBRELYTE FL30-18 JUMBO
ROUND POLYMER CONCRETE VALVE BOX
WITH 6" EXTENSION AND LID WITH
MARKINGS
SCH 40 PVC PIPING
CURB STOP VALVE
SCH 80 PVC NIPPLE 3/4" X 6"
ADJUSTABLE PRESSURE REGULATOR 3/4"
DI SERVICE TEE WITH 3/4" OUTLET
MAINLINE PIPE AND SERVICE
TEE
3/4" PVC PIPING WITH
FITTINGS
LATERAL TEE
LATERAL PIPE
MANUFACTURED SWING JOINT
POP UP ROTOR SPRINKLER
APPROVED BACKFILL
NOTE: INSTALL SPRINKLER HEAD BETWEEN
1/4" AND 1/2" BELOW TOP OF
SPRINKLER BLOCK (COLLAR)
CHRISTY CONCRETE SPRINKLER
BLOCK - INSTALL PER MANUFACTURER'S
RECOMMENDATIONS
2" GRAVEL BASE
APPROVED BACKFILL
SPRINKLER
MPR NOZZLES
(SIZE PER PLAN)
AT FINISHED GRADE
NOTE: INSTALL SPRINKLER
SCALE:
5 FIXED-SPRAY SPRINKLER
NONE
LATERAL TEE
LATERAL PIPE
SWING JOINT PER
SPECIFICATIONS
8' M
IN
SCALE:
11 RAIN/FREEZE SENSOR
NONE
3/4" COPPER MIPT X SWEAT
FILTER FABRIC
3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL
4" COMPACTED AGGREGATE BASE
3/4" COPPER TYPE K PIPING TO
HYDRANT
A1
FINISHED GRADE
SCHEDULE 80 PVC 90 DEGREE
SLIP ELBOW
SCHEDULE 80 PVC TOE NIPPLE
14-INCH
SCHEDULE 80 PVC TOE NIPPLE
14-INCH
DI SERVICE TEE
PVC MAINLINE 30-INCH BURY
1. PLACE 1/2-INCH WIRE MESH & FILTER FABRIC UNDERNEATH VALVE BOX AND
ON TOP OF AGGREGATE BASE.
2. INSTALL VALVE BOX +/- 3/4-INCH ABOVE FINISH GRADE WHEN INSTALLING SOD.
3. ATTACH ID TAG WITH STATION NUMBER TO SOLENOID CONTROL WIRE.
4. APPLY EXPANDABLE FOAM AT PIPE OPENING.
5. REMOVE MATERIAL TO PROVIDE 6-INCHES OF CLEARANCE AROUND THE
ENCLOSURE AND 4-INCHES IN ADDITIONAL DEPTH ALLOWING FOR BEDDING.
6. COMPACT SUBGRADE BEFORE INSTALLING AGGREGATE BASE.
7. INSTALL TWO PVC CONDUITS FOR TWO-WIRE; ONE FOR WIRE IN AND ONE FOR
WIRE OUT.
FIBRELYTE VALVE BOX FL30-18 WITH
FIBRELYTE VALVE BOX EXTENSION FL30-6X
VALVE ID TAG
4" COMPACTED AGGREGATE BASE
3" MINIMUM GRAVEL SUMP
CLASS 200 PVC LATERAL 18-INCH BURY
SCHEDULE 40 PVC MALE ADAPTER
SCHEDULE 80 PVC THREADED UNION
WATERPROOF WIRE CONNECTORS
SOLENOID CONTROL WIRE
AUTOMATIC CONTROL VALVE
WIRE MESH & FILTER FABRIC
SCHEDULE 80 PVC NIPPLE 3-INCH
BRASS BALL VALVE
ONE-STATION DECODER
PVC CONDUIT FOR TWO-WIRE CABLE
WITH PVC CONDUIT SWEEP ELL (TWO
REQUIRED)
TWO-WIRE CABLE
POLYMER CONCRETE VALVE BOX 2424-24
4" COMPACTED AGGREGATE BASE
3" MINIMUM GRAVEL SUMP
DI SERVICE TEE WITH 2-INCH OUTLET
AUTOMATIC CONTROL VALVE
WIRE MESH & FILTER FABRIC
BRASS BALL VALVE
PVC MAINLINE 30-INCH BURY
SCHEDULE 80 PVC NIPPLE 2-INCH X 10-INCH
6"
AIR/VACUUM RELIEF VALVE 2-INCH
FINISHED GRADE
1. PLACE 1/2-INCH WIRE MESH & FILTER FABRIC UNDERNEATH VALVE BOX AND
ON TOP OF AGGREGATE BASE.
2. INSTALL VALVE BOX +/- 3/4-INCH ABOVE FINISH GRADE WHEN INSTALLING SOD.
3. APPLY EXPANDABLE FOAM AT PIPE OPENING.
4. REMOVE MATERIAL TO PROVIDE 6-INCHES OF CLEARANCE AROUND THE
ENCLOSURE AND 4-INCHES IN ADDITIONAL DEPTH ALLOWING FOR BEDDING.
5. COMPACT SUBGRADE BEFORE INSTALLING AGGREGATE BASE.
SCALE:
9 AIR RELIEF VALVE ASSEMBLY
NONE
FEMALE ADAPTER (SLIP X FIPT)
GALVANIZED 90° EL (1 OF 2)
3/4-INCH GALVANIZED PIPE
RAIN SENSOR
FINISHED GRADE
CONCRETE BASE
WIRE TO IRRIGATION CONTROLLER
NOTES:
1. MOUNT SENSOR VERTICALLY. AVOID PLACEMENT UNDER
EVE OR TREE CANOPY. LOCATE WITHIN 500 FEET (LINE
OF SIGHT) OF SENSOR RECEIVER AND CONTROLLER
2. COORDINATE ACTUAL LOCATION WITH OWNER'S
REPRESENTATIVE BEFORE ACTUAL INSTALLATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\d es ig n pr oj ec ts
\m ar e is la nd n av al c em et er y\
- d ra w in gs
\m ar e is la nd n c irr ig at io n.
dw ch ris m er te d:
4/
/2
:2 lo t:4
/3 0/
0:
A
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18181Date:
Office of Design and Construction
Services
MARE ISLAND NAVAL CEMETERY
962-003
MAY 4, 2026
IMHOFF ROAD, VALLEJO, CA, 94592
BID DOCUMENTS
GEOTECHNICAL/HAZMATENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
BID DOCUMENTS
2026.05.04
IR501
X
IRRIGATION DETAILS
PIPE
SIZE
2"
2.5"
3"
4"
5"
4.56
6.65
9.80
16.2
24.7
DEAD END
OR TEE
90°
ELBOW
45°
ELBOW
22.5°
ELBOW
1.5" 2.94
3.5" 12.8
6" 34.8
6.45
9.40
13.9
23.0
35.0
4.16
18.1
49.2
3.50
5.10
7.51
12.4
18.9
2.25
9.81
26.7
1.78
2.60
3.82
6.31
9.63
1.15
4.99
13.6
BASED ON POUNDS PER PSI WORKING PRESSURE.
STEP 1. MULTIPLY THE PRESSURE LEVEL DESIRED FOR
TESTING BY THE APPROPRIATE VALUE SHOWN IN THE
FOLLOWING TABLE:
STEP 2. DETERMINE THE BEARING STRENGTH OF THE SOIL
FROM THE TABLE BELOW:
BEARING STRENGTH OF SOILS
SOILS AND SAFE BEARING LOADS LBS. SQ. FT.
SOUND SHALE
CEMENTED GRAVEL AND
SAND-DIFFICULT TO PICK
COARSE AND FINE
COMPACT SAND
MEDIUM CLAY -
CAN BE SPADED
SOFT CLAY
MUCK
10,000
4,000
3,000
2,000 1,000
STEP 3. DIVIDE THE TOTAL THRUST OBTAINED IN STEP 1 BY
THE BEARING STRENGTH OF THE SOIL: THIS GIVES THE
SQUARE FEET OF AREA NEEDED.
THRUST BLOCKING
AN OUTWARD PRESSURE EXISTS ON ALL DEFLECTIONS
FROM A STRAIGHT LINE. GOOD SOIL, PROPERLY TAMPED, IS
SUFFICIENT TO HOLD SIDE THRUST - UNLESS SOIL
CONDITIONS ARE UNSTABLE. IN THAT CASE, TO ANCHOR
AGAINST THIS SIDE THRUST, THE BLOCKING SHOULD BE
PLACED AGAINST THE PIPE ON EACH SIDE OF THE COUPLING.
DO NOT THRUST BLOCK THE COUPLING ITSELF.
SIDE THRUST ON CURVES
PIPE SIZE
INCHES
2"
2.5"
3"
4"
5"
SIDE THRUST
POUNDS PER DEGREE
1.5"
3.5"
6"
7.9
11.6
17.1
28.3
43.1
5.1
22.4
60.8
BASED ON SIDE THRUST PER 100 LBS/SQUARE INCH
PRESSURE PER DEGREE OF DEFLECTION
NOTE: MULTIPLY SIDE THRUST POUNDS BY DEGREES OF
DEFLECTION TIMES POUNDS OF PRESSURE DIVIDED BY 100
TO OBTAIN TOTAL SIDE THRUST IN POUNDS.
NOTES:
ALL MAINLINE AND LATERAL CHANGE OF DIRECTION SHALL
RECEIVE THRUST BLOCKING OR JOINT RESTRAINTS. - SEE
THRUST BLOCKING TABLE FOR BEARING STRENGTH.
FURTHERMORE ANY SOILS NOT STABLE FOR ADEQUATE
THRUST BLOCKING, SAID FITTINGS MUST UTILIZE JOINT
RESTRAINTS AT NO ADDITIONAL COST TO OWNER. IT IS
ULTIMATELY THE CONTRACTORS RESPONSIBILITY TO INSTALL
THE APPROPRIATE APPLICATION TO ENSURE THAT THE FITTING
OR VALVE DOES NOT MOVE FROM A OUTWARD DEFLECTION.
WYE
45° ELL 45° ELL
UNDISTURBED SOIL (TYPICAL)
PIPE (TYPICAL)
CONCRETE THRUST BLOCK
FITTING (TYPICAL)
FITTING (TYPICAL)
REBAR BENT AROUND
(TYPICAL)
ELL
CROSS TEE
SCALE:
3 THRUST BLOCK DETAIL
NONE
SCALE:
SPRINKLER INSTALLATION
WITHIN BURIAL PLOTS
NONE
30° TRAJECTORY
SPRINKLER
HEADSTONE - TYPICAL
4'-0" IRRIGATION AISLE
BURIAL PLOT - TYPICAL
NOTES:
1. SPRINKLERS INSTALLED WITHIN BURIAL
PLOTS REQUIRE NOZZLE OUTLET
TRAJECTORY IN EXCESS OF 30-DEGREES
TO CLEAR GRAVE HEADSTONES.
2. LOCATE SPRINKLER IN THE CENTER OF
THE IRRIGATION AISLE POSITIONED
PERPENDICULAR TO THE BURIAL PLOTS
AND MID POINT BETWEEN HEADSTONE
ROWS FOR ADJOURNING BURIAL PLOTS.
3. FOR UPRIGHT HEADSTONES THE
SPRINKLER SHALL BE SPACED
EQUIDISTANT BETWEEN THE ADJOINING
HEADSTONE.
EQ.
4'-0" 4'-
9"
4'-9"
EQ.
4'-9"
4'- 9"
EQ
EQ
IRRIGATION PIPING TO BE 4" BELOW TO OF
CRYPT LID SEE CRYPT DETAIL
4'
8"
HEADSTONE LOCATION
IRRIGATION AISLE BOUNDRY
6" NIPPLE
MANUFACTURED SWING JOINT
(AS SPECIFIED)
LARGE TURF SPRINKLER
GRID MONUMENT
SCALE:
2 SPRINKLER PLACEMENT
NONE
NOTES:
1. CONTRACTOR RESPONSIBLE FOR STAKING TRENCH
LOCATION IN THE CORRECT LOCATION WITHIN AISLES.
2. CENTER OF SPRINKLER WILL BE ALIGNED WITH CENTERLINE
OF AISLE
46.56"
EQ
EQ
EQ.EQ.
46.56" 46.56"
46.56"
4'
RAIN BIRD 8005
SPRINKLER
HEADSTONE - TYPICAL
4'-0" IRRIGATION AISLE
BURIAL PLOT - TYPICAL
NOTES:
1. LOCATE SPRINKLER IN THE CENTER OF THE
IRRIGATION AISLE POSITIONED PERPENDICULAR TO
THE BURIAL PLOTS AND MID POINT BETWEEN
HEADSTONE ROWS FOR ADJOURNING BURIAL PLOTS.
2. FOR UPRIGHT HEADSTONES THE SPRINKLER SHALL
BE SPACED EQUIDISTANT BETWEEN THE ADJOINING
HEADSTONE.
3. EXACT LOCATION OF SPRINKLER IS NECESSARY
ALONG WITH HEAD PLUMB SET TO ENSURE NO
CONTACT WITH MAIN NOZZLES AND HEAD STONE(S).
KEEP SPRINKLER A MINIMUM 12"
AWAY FROM GRID MONUMENT
SCALE:
4 CONTROLLER
NONE
SET SCREW ACCESS PLUG
CONNECTORS
HEX SET SCREW
CONDUCTOR LUG
CONDUCTOR SLEEVE
ALLEN WRENCH (3/16")
WIRE FROM GROUND PLATE
(GREEN/YELLOW)
BONDING/SHIELDING WIRES
10 AWG SOLID BARE COPPER
S1
WHT
BLK
600 FEET
MAXIMUM
WHT
BLK
DEC-SG
300 FEET
MAXIMUM
DECODER
2-WIRE MODULE
BLUE
BLUE
RKLD TO SOLENOID
WIRE (PAIGE ELECTRIC P7351D) RUN CANNOT
EXCEED 400 FEET
8 FEET (2.5M)
±10% COPPER
ROD
PD
D
2- W
IR
E
C
AB
LE
PD
D
2-
W
IR
E C
AB
LE
PD
D
2- W
IR
E
C
AB
LE
* (PD7350D) 14/2 (2.1mm ) JACKETED 2-WIRE CABLE
SEE 1, 2, OR 4 STATION DECODER MODULE DETAILS
WHITE
WHITE
RED
JACKETED 14/2 (2.1mm²)
P7351D DTS CABLE
SCALE:
6 PAIGE RE- ENTERABLE CONNECTOR # 270RCX
NONE
10" ROUND VALVE BOX
8' (2
.5 M
) M
IN
ROD - GREEN/YELLOW
SURGE ARRESTOR (SEE NOTES)
3M DBR/Y-6 WIRE CONNECTOR
PAIGE P7350D
14/2 AWG (2.1mm )
COMM CABLE
NOTES:
- SHOW FOR DIAGRAMATIC PURPOSES
- AT SPLICE LOCATIONS PROVIDE SUFFICIENT SLACK
TO ALLOW THE SPLICE TO BE RAISED A MINIMUM OF
24" (600mm) ABOVE GRADE.
- THE SPLICES AND WIRE SLACK SHOULD BE SECURED
INSIDE OF THE VALVE BOX WITH TAPE OR NYLON ZIP
TIES. THE WIRES SHOULD BE COILED NO LESS THAN
THE DIAMETER OF A 1.5" (40mm) PVC PIPE. DO NOT
CREATE SHARP BENDS.
#6 (16mm²) SOLID COPPER
INSULATED WIRES
5/8" X 8' COPPER CLAD GROUND ROD TO
ACHIEVE 10 OHMS RES.
GROUND ROD SHOULD BE 8' (2.5M) ±10% FROM
THE SURGE ARRESTOR
3M DBR/Y-6 WIRE CONNECTORS
(SEE NOTES)
SERVICE
EXPANSION
COIL (SEE
NOTES)
SCALE:
5 COMMUNICATION CABLE SURGE ARRESTOR
NONE
DEC-SG
S1DECODER
2-WIRE MODULE
BLUE
BLUE
WHITE
WHITE
RED
JACKETED 14/2 (2.1mm²)
P7351D DTS CABLE
S1DECODER
2-WIRE MODULE
BLUE
BLUE
WHITE
WHITE
RED
JACKETED 14/2 (2.1mm²)
P7351D DTS CABLE
SCALE:
7 SURGE PROTECTION DIAGRAM
NONE
GROUND WIRE (GREEN
FROM DECODER OR
LIGHTNING ARRESTER OR
DECODER CABLE FUSE
DEVISE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\d es ig n pr oj ec ts
\m ar e is la nd n av al c em et er y\
- d ra w in gs
\m ar e is la nd n c irr ig at io n.
dw ch ris m er te d:
4/
/2
:2 lo t:4
/3 0/
0:
A
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18181Date:
Office of Design and Construction
Services
MARE ISLAND NAVAL CEMETERY
962-003
MAY 4, 2026
IMHOFF ROAD, VALLEJO, CA, 94592
BID DOCUMENTS
GEOTECHNICAL/HAZMATENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
BID DOCUMENTS
2026.05.04
IR502
X
IRRIGATION DETAILS
CJM CJM
AutoCAD SHX Text
²) JACKETED 2-WIRE CABLE
AutoCAD SHX Text ²)
STATION COMPONENTS:
A PUMP AND MOTOR
B CHECK VALVE
C PRESSURE TRANSDUCER WITH GAUGE
D STAINLESS STEEL BASE (UNPAINTED)
E FLOW SENSOR
F TEMP SENSOR
G STATION FAN (HOOD MOUNTED)
H DISCHARGE ISOLATION VALVE
I MARINE GRADE ALUMINUM ENCLOSURE (UNPAINTED)
J INTAKE DROP PIPE W/ 4" FLG CONNECTION
K DISCHARGE DROP PIPE W/ 4" FLG CONNECTION
L 3" FEBCO LF880V RPZ
M BY-PASS VALVE
N INTERNAL SOUND DAMPENING MATERIAL
D
L
WATERTRONICS
0 200
WATERTRONICS
0 200 psi
WATERTRONICS
0 200
VFD
3" RPZ FLUSH LINE
TO WASTE OR DRAIN BY OTHERS
81"
SLAB
3" J
I
H
D -F
C O
N
TR
O L
C
AB
IN
ET
60"
SLAB42"
BASE
SEE LOCAL
NEC CODES
42" MINIMUM
G
F
FRONT OF ENCLOSURE
A
69"
BASE
CB
DETAIL A
CONCRETE ANCHOR
BOLTS (x4) LOCATIONS
DETAIL A
E
FLOW
M
PUMP STATION SPECIFICATIONS:
NAME: MARE ISLAND NAVAL CEMETERY
STATION MODEL: WMBV-7000-7A-15-240-1-200-105
STATION TOTAL PERFORMANCE: 200 GPM @ 105 PSI
DYNAMIC INLET PRESSURE: 55 PSI (AFTER RPZ)
BOOST PRESSURE: 50 PSI
REGULATED DISCHARGE PRESSURE: 105 PSI
PUMP HORSEPOWER:
PUMP NO.1: 15HP (3600RPM)
CHECK VALVE SIZES:
PUMP NO.1: 4"
ISOLATION VALVE SIZES:
DISCHARGE ISOLATION VALVE SIZE: 3"
DISCHARGE MANIFOLD SIZE: 3"
POWER REQUIREMENTS: 240V, 1PH, 60HZ, 94FLA (EST.)
N
J K
CONCEPT DRAWING ONLY
NOT FOR CONSTRUCTION
DATENO.
DESCRIPTIONBY
THIS DRAWING AND DESIGN, IS THE
PROPERTY OF WATERTRONICS AND IS
NOT TO BE REPRODUCED IN WHOLE OR
PART, NOR EMPLOYED FOR ANY PURPOSE
OTHER THAN SPECIFICALLY PERMITTED IN
WRITING BY WATERTRONICS.
THIS DRAWING LOANED AND SUBJECT
TO RETURN ON DEMAND JOB NO.:
NTSSCALE:
DRAWN BY:
OF
DRAWING NO.
DATE:
SHEET SHEETS
TITLE:
WATERTRONICS
A LINDSAY COMPANY
APPROVED AS SUBMITTED
APPROVED AS NOTED
REVISE AND RESUBMIT
SIGNATURE: _______________________
CHECKED BY:
DATE: ___________
NAME: ____________________________
DATE: MARE ISLAND NAVAL CEMETERY
IRRIGATION PUMP STATION
PRST15739
10/31/2025PJB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\d es ig n pr oj ec ts
\m ar e is la nd n av al c em et er y\
- d ra w in gs
\m ar e is la nd n c irr ig at io n.
dw ch ris m er te d:
4/
/2
:2 lo t:4
/3 0/
0:
A
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18181Date:
Office of Design and Construction
Services
MARE ISLAND NAVAL CEMETERY
962-003
MAY 4, 2026
IMHOFF ROAD, VALLEJO, CA, 94592
BID DOCUMENTS
GEOTECHNICAL/HAZMATENVIRONMENTAL:
TERRACON
1900 GARDEN ROAD SUITE 210
MONTEREY, CA 93940
831-574-7013
POINT OF CONTACT
JESS SUTTON
COST ESTIMATING:
OCMI
8851 RESEARCH DRIVE
IRVINE, CA 92618
702-339-9870
POINT OF CONTACT
ALLICIA WARNER
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES, IA 50265
515-225-6365
POINT OF CONTACT
LISA ESSY
BID DOCUMENTS
2026.05.04
IR503
X
IRRIGATION PUMP DETAILS
OS
DL
LC
J
J
F1
DO
M
OS
1P 1 Pole (2P, 3P, 4P, ETC.)
A, Amp Ampere AC Above Counter ACLG Above Ceiling ADO Automatic Door Opener AF Amp Frame AFF Above Finished Floor AFG Above Finished Grade AFI Arc Fault Circuit
Interrupter AHU Air Handling Unit AL Aluminum ALT Alternate AMP Ampere AMPL Amplifier ANNUN Annunciator APPROX Approximately AQ-STAT Aquastat ARCH Architect, Architectural AS Amp Switch AT Amp Trip ATS Automatic Transfer Switch AUTO Automatic AUX Auxiliary AV Audio Visual AWG American Wire Gauge BATT Battery BD Board BLDG Building BMS Building Management System C Conduit CAB Cabinet CAT Catalog CATV Cable Television CB Circuit Breaker CCTV Closed Circuit Television CKT Circuit CLG Ceiling COMB Combination CMPR Compressor CONN Connection CONST Construction CONT Continuation Or Continuous CONTR Contractor CONV Convector CP Circulating Pump CRT Cathode-Ray Tube CT Current Transformer CTR Center CU Copper DCP Domestic Water Circulating Pump DEPT Department DET Detail DIA Diameter DISC Disconnect DIST Distribution DN Down DPR Damper DS Safety Disconnect Switch DT Double Throw DWG Drawing EC Electrical Contractor ELEC Electric, Electrical ELEV Elevator ELU Emergency Lighting Unit EM Emergency EMS Energy Management System EMT Electrical Metallic Tubing EP Electric Pneumatic EQUIP Equipment EWC Electric Water Cooler EXIST Existing EXH Exhaust EXP Explosion Proof FA Fire Alarm FABP Fire Alarm Booster Power
Supply Panel FACP Fire Alarm Control Panel FCU Fan Coil Unit FIXT Fixture FLR Floor FLUOR Fluorescent FU Fuse FUDS Fused Safety Disconnect Switch GA Gauge GAL Gallon GALV Galvanized GC General Contractor GEN Generator GFI Ground Fault Circuit Interrupter GFP Ground Fault Protector GND Ground GRS Galvanized Rigid Steel (Conduit) GYP BD Gypsum Board HOA Hands-Off-Automatic Switch HORIZ Horizontal HP Horsepower HPF High Power Factor HT Height HTG Heating HTR Heater HV High Voltage HVAC Heating, Ventilating And Air
Conditioning IC Interrupting Capacity IG Isolated Ground IMC Intermediate Metal Conduit INCAND Incandescent IR Infrared I/W Interlock With J-BOX Junction Box KV Kilovolt KVA Kilovolt-Ampere KVAR Kilovolt-Ampere Reactive KW Kilowatt KWH Kilowatt Hour LOC Locate Or Location LT Light LTG Lighting LTNG Lightning LV Low Voltage MAX Maximum MAG.S Magnetic Starter M/C Momentary Contact MC Mechanical Contractor
Electrical Abbreviations
Electrical DeviceTags: Uppercase letter(s) indicates Panel ID and circuit number. Lowercase letter indicates designation of controlling switch (where applicable).
Switch ID indicated by a lowercase letter. Switch IDs are unique per space. A switch with an ID "a" controls all devices within the space in which it is located tagged with "a". A switch without a tagged ID controls all lighting fixtures within a space. ID tags may be used on control devices other than switches, such as occupancy sensors or contactors.
Equipment Tags: Equipment ID is indicated by an underlined tag adjacent to the equipment. See the equipment connection schedule for description, electrical requirements, and panel and circuit number. Symbols/graphic appearance of equipment varies.
Solid, arced lines connecting equipment, devices, or fixtures indicate unswitched power circuiting. Wires are only intended to indicate to what circuit devices are connected. Actual connections, circuit routing, installtion, junction boxes, etc. shall be field-determined by the contractor.
Home run to branch circuit panelboard. The equipment name and circuit number(s) are indicated, separated by a hyphen. Homeruns are only intended to indicate panel and circuit number. Actual homerun location shall be field-determined by the contractor.
Power Symbols
Electrical Symbol Legend
Room
MCB Main Circuit Breaker MCC Motor Control Center MDC Main Distribution Center MDP Main Distribution Panel MFR Manufacturer MFS Main Fused Disconnect Switch MH Manhole MIC Microphone MIN Minimum MISC Miscellaneous MLO Main Lugs Only MMS Manual Motor Starter MOA Multioutlet Assembly MSP Motor Starter Panelboard MSBD Main Switchboard MSS Motor Starter Switch MT Mount MT.C Empty Conduit MTS Manual Transfer Switch MTR Motor, Motorized N.C. Normally Closed NEC National Electrical Code NEMA National Electrical
Manufacturer's Association NFDS Non-Fused Safety Disconnect
Switch NIC Not In Contract NL Night Light N.O. Normally Open NPF Normal Power Factor NTS Not To Scale OC On Center OH Overhead OL Overloads PA Public Address PB Pull Box Or Pushbutton PE Pneumatic Electric PED Pedestal PF Power Factor PH Phase PIV Post Indicating Valve PNL Panel PP Power Pole PR Pair PRI Primary PROJ Projection PRV Power Roof Ventilator PT Potential Transformer PVC Polyvinyl Chloride (Conduit) PWR Power QUAN Quantity RCPT Receptacle REQD Required RM Room RSC Rigid Steel Conduit RTU Roof Top Unit SC Surface Conduit SEC Secondary SHT Sheet SIM Similar SLD Single-Line Diagram S/N Solid Neutral SPEC Specification SPKR Speaker SP Spare SPP Single-Point Power SR Surface Raceway SS Stainless Steel SSW Selector Switch S/S Stop/Start Pushbuttons STA Station STD Standard SURF Surface Mounted SW Switch SWBD Switchboard SYM Symmetrical SYS System TEL Telephone TERM Terminal TL Twist Lock TR Tamper Resistant T-STAT Thermostat TTC Telephone Terminal Cabinet TV Television TVTC Television Terminal Cabinet TYP Typical UC Under Counter UE Underground Electrical UG Underground UH Unit Heater UT Underground Telephone UTIL Utility UV Ultraviolet V Volt VA Volt-Amperes VDT Video Display Terminal VERT Vertical VFD Variable…