PACKAGE_21-SOUTH_MEETING_ROOM_S321-Bid.pdf
PDF 45 MB Posted
- Solicitation number
- Y25-729
- Issued by
- Orange County, Orlando City, Florida
About this file
This document is a comprehensive set of construction documents for the Orange County Convention Center North South Building Meeting Rooms Renovation project, involving Orange County, Florida and multiple architectural, engineering, and design firms. The project encompasses the interior renovation of 25 meeting rooms on the concourse and mezzanine levels, with each meeting room submitted as a separate permit package. The renovation scope includes demolition of existing interior finishes, operable walls, ceiling systems, lighting fixtures, and HVAC components, followed by installation of new wall, ceiling, and floor finishes, updated lighting, mechanical systems, and additional power and data outlets. The project is scheduled for permit issuance on September 9, 2024, and bid issuance on September 20, 2024, with an estimated total project cost of $45,700,067.00.
The renovation will maintain existing structural supports, ductwork, and building systems while upgrading the meeting rooms' functionality and aesthetic appeal. The project adheres to the 2023 Florida Building Code, Florida Fire Prevention Code, and other applicable state and national standards. Two signature meeting rooms (N230 & N330) will feature upgraded design elements and finishes, including glazed curtain wall installations. The project does not significantly alter the building's life safety or egress components, with careful consideration given to preserving the existing infrastructure while modernizing the meeting spaces. The work will be phased to minimize disruption to the convention center's operations, with temporary construction barriers and coordinated sequencing to ensure continuous facility functionality.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT TEAM
PROJECT LOCATION MAP
BOARD OF COUNTY COMMISSIONERS
SHEET SPECIFIC NOTES
PROJECT DESCRIPTION
APPLICABLE CODES
ARCHITECT - PRIME
TVS FLORIDA, INC., ARCHITECTURE
442 W. KENNEDY BOULEVARD
SUITE 302
TAMPA, HILLSBOROUGH, FL 33606
Phone: 404 888 6600
MECHANICAL, ELECTRICAL (SOUTH)
TLC ENGINEERING
SOLUTIONS(ENGINEER OF RECORD)
255 SOUTH ORANGE AVENUE
ORLANDO, ORANGE, FL 32801
Phone: 305 266 6553
COST SERVICES
BLUE CORD DESIGN AND
CONSTRUCTION, LLC
835 BENNETT ROAD
ORLANDO, ORANGE, FL 32803
Phone: 407 425 1390
ASSOCIATE ARCHITECT
RHODES & BRITO ARCHITECTS INC.
(ARCHITECT OF RECORD)
605 E, ROBINSON STREET
SUITE 750
ORLANDO, ORANGE, FL 32801
Phone: 407 648 7288
MECHANICAL, ELECTRICAL (NORTH)
AVCON, INC.
5555 E. MICHIGAN STREET
STE. 200
ORLANDO, ORANGE, FL 32822
Phone: 407 599 1122
LIGHTING
CM KLING + ASSOCIATES, INC.
1020 CAMERON STREET
ALEXANDRIA ,VA 22314
Phone: 703 684 6270
INTERIOR DESIGN
ALLIANCE DESIGN & CONSTRUCTION,
INC.
PO BOX 1296
SUITE 302
WINTER PARK, ORANGE COUNTY, FL 32790
Phone: 407 467 8833
ARCHITECTURAL QUALITY
ASSURANCE AND CONTROL
ROGER A. REPSTIEN, D/B/A, RDC,
524 FERNWOOD DRIVE
ALTAMONTE SPRINGS, SEMINOLE, FL 32803
Phone: 800 362 1523
FACILITY ASSESSMENT
PIERCE FLORIDA REALTY
1431 ROYAL ST. GEORGE DRIVE
ORLANDO, FL 32828
Phone: 407 567 9077
QUALITY ASSURANCE AND CONTROL
FOR MECHANICAL, ELECTRICAL
ABOVE GROUP, INC.
111 NORTH ORANGE AVENUE
STE. 800
ORLANDO, ORANGE, FL 32801
Phone: 321 345 9026
STRUCTURAL
ADVANCED STRUCTURAL DESIGN, INC.
1035 S SEMORAN BLVD
STE. 1019
WINTER PARK, FL 32792
Phone: 407 677 5836
© Google Earth Pro
N
JERRY L. DEMINGS
COUNTY MAYOR
NICOLE H. WILSON
DISTRICT 1 COMMISSIONER
MARIBEL GOMEZ CORDERO
DISTRICT 4 COMMISSIONER
CHRISTINE MOORE
DISTRICT 2 COMMISSIONER
MAYRA URIBE
DISTRICT 3 COMMISSIONER
EMILY BONILLA
DISTRICT 5 COMMISSIONER
MICHAEL SCOTT
DISTRICT 6 COMMISSIONER
PROJECT MASTER INDEX
NUMBER PACKAGE NAME
01 PACKAGE 01-NORTH MEETING ROOM N210
PACKAGE 02-NORTH MEETING ROOM N220
PACKAGE 03-NORTH MEETING ROOM N230
PACKAGE 04-NORTH MEETING ROOM N310
PACKAGE 05-NORTH MEETING ROOM N311
PACKAGE 06-NORTH MEETING ROOM N312
PACKAGE 07-NORTH MEETING ROOM N319
PACKAGE 08-NORTH MEETING ROOM N320
PACKAGE 09-NORTH MEETING ROOM N321
PACKAGE 10-NORTH MEETING ROOM N322
PACKAGE 11-NORTH MEETING ROOM N329
PACKAGE 12-NORTH MEETING ROOM N330
PACKAGE 13-SOUTH MEETING ROOM S210
PACKAGE 14-SOUTH MEETING ROOM S220
PACKAGE 15-SOUTH MEETING ROOM S230
PACKAGE 16-SOUTH MEETING ROOM S310
PACKAGE 17-SOUTH MEETING ROOM S311
PACKAGE 18-SOUTH MEETING ROOM S312
PACKAGE 20-SOUTH MEETING ROOM S320
PACKAGE 21-SOUTH MEETING ROOM S321
PACKAGE 22-SOUTH MEETING ROOM S322
PACKAGE 19-SOUTH MEETING ROOM S319
PACKAGE 23-SOUTH MEETING ROOM S329
PACKAGE 24-SOUTH MEETING ROOM S330
PACKAGE 25-SOUTH MEETING ROOM S331
A01-201
A= ARCHITECTUEAL
G=GENERAL*
E=ELECTRIC
M=MECHANICAL
S=STRUCTURAL
*G SERIES COMMON
FOR ALL PACKAGES
PACKAGE NUMBER
SERIES
SHEET
SHEETS NAMING SYSTEM
DISCIPLINE
PROJECT DESCRIPTION:
INTERIOR RENOVATION OF 25 MEETING ROOMS ON THE CONCOURSE
AND MEZZANINE LEVEL AT THE ORANGE COUNTY CONVENTION
CENTER - NORTH SOUTH BUILDING. EACH MEETING ROOM WILL BE
SUBMITTED AS A SEPARATE PERMIT PACKAGE.
TYPICAL MEETING ROOMS:
DEMOLITION OF INTERIOR FINISHES, OPERABLE WALLS AND TRACKS,
CEILING SOFFITS, ACOUSTICAL CEILING TILE AND GRID, LIGHTING
FIXTURES, CEILING DEVICES, AIR TERMINAL UNITS, WALL MOUNTED
FIRE ALARM STROBES, AND HVAC DIFFUSERS.
PROPOSED WORK GENERALLY INCLUDES, BUT IS NOT LIMITED TO,
NEW WALL, CEILING AND FLOOR FINISHES, OPERABLE WALLS AND
TRACKS, LIGHT FIXTURES, HVAC DIFFUSERS, AIR TERMINAL UNITS,
CEILING MOUNTED FIRE ALARM STROBES, AND ADDITIONAL POWER
AND DATA OUTLETS WHERE REQUESTED. EXISTING CEILING AND
WALL DEVICES THAT ARE REMOVED TO ALLOW INSTALLATION OF NEW
FINISHES WILL BE SALVAGED AND REINSTALLED OR REPLACED WITH
NEW DEVICES IN THEIR ORIGINAL LOCATIONS.
EXISTING STRUCTURAL SUPPORTS, DUCTWORK, OTHER BRANCH
SERVICES, AND RACEWAYS ARE TO REMAIN AS-IS. ADDITIONAL
SUPPORTS AND RACEWAYS ARE BEING PROVIDED WHERE REQUIRED.
SIGNATURE MEETING ROOMS N230 & N330 (PACKAGES 3 & 12):
SAME SCOPE AS TYPICAL MEETING ROOMS, HOWEVER THE
RENOVATION SCOPE INCLUDES UPGRADED DESIGN ELEMENTS AND
FINISHES, AS WELL AS ADDING GLAZED CURTAIN WALL ALONG
PORTIONS OF THE INTERIOR AND EXTERIOR WALLS. THE FIRE AND
SMOKE RATING OF THE EXISTING WALLS WILL BE MAINTAINED.
THIS PROJECT DOES NOT AFFECT EXISTING LIFE SAFETY OR EGRESS
COMPONENTS OF THE FACILITY EXCEPT FOR MEETING ROOM N330. REFER
TO PACKAGE 12 FOR ADDITIONAL CLARIFICATION.
TEMPORARY CONSTRUCTION BARRIER PLANS AND DETAILS ARE INCLUDED
WHERE APPLICABLE. CONTRACTOR SHALL PROVIDE TEMPORARY
CONSTRUCTION BARRIERS AS REQUIRED BY CONTRACTOR'S MEANS AND
METHODS AND/OR AS INDICATED ON DRAWINGS.
BUILDING: 2023 FLORIDA BUILDING CODE, EXISTING NORTH SOUTH BUILDING, ALTERATION LEVEL 1 LIFE SAFETY: 2023 FLORIDA FIRE PREVENTION CODE (NFPA 101 LIFE SAFETY CODE, 2021 EDITION)
MECHANICAL: 2023 FLORIDA BUILDING CODE, MECHANICAL
PLUMBING: 2023 FLORIDA BUILDING CODE, PLUMBING
ELECTRICAL: NFPA 70 NATIONAL ELECTRICAL CODE, 2020 EDITION
ENERGY: 2023 FLORIDA BUILDING CODE, ENERGY CONSERVATION
FIRE: 2023 FLORIDA FIRE PREVENTION CODE
ACCESSIBILITY: 2023 FLORIDA BUILDING CODE, ACCESSIBILITY
NOTE: THE ORIGINAL BUILDING WAS DESIGNED TO COMPLY WITH THE 1997 STANDARD BUILDING
CODE AND 1997 NFPA LIFE SAFETY CODE
N
S321 A-21
SHEET NUMBER
442 W Kennedy Blvd Suite 312 Tampa Florida 33606 tvsdesign.com
SHEET TITLE
SEAL
987654321
B
A
D
C
TVS PROJECT NUMBER
F
E
H
G
J
K
B
A
D
C
F
E
H
G
J
K
987654321
TVS FLORIDA, INC., ARCHITECTURE
Scales as stated hereon are valid on the original drawing, the dimensions of which are 30x42 inches. These scales noted hereon are hereby changed by the ratio of the overall sheet dimensions of the print to the corresponding dimensions of the original drawing.
© TVS FLORIDA, INC., ARCHITECTURE
This drawing is the property of TVS FLORIDA, INC., ARCHITECTURE and is not to be reproduced or copied in whole or in part. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
M
L
N
M
L
N
RELEASED FOR CONSTRUCTION
ORIGINAL ISSUE DATE
P P
605 E. ROBINSON STREET, SUITE 750 ORLANDO, FL 32801
407.648.7288 www.rbarchitects.com AR0014284
9/
/2
3:
:4
P
M A ut od es k
D oc s:
//P
-2
O ra ng e
C ou nt y
C on ve nt io n
C en te r/
P -2
_A R
C H
_I nt er io r.
rv t
G-000-21
COVER SHEET - PACKAGE 21 - MEETING ROOM S321
9899 International Dr, Orlando, FL 32819
P-20257
09/09/24
09/09/2024
OCCC NORTH SOUTH BUILDING
MEETING ROOMS RENOVATION
SHEET INDEX - PACKAGE 21 MEETING ROOM S321
Sheet Number Sheet Name
COVER SHEETS
G-000-21 COVER SHEET - PACKAGE 21 - MEETING ROOM S321
ARCHITECTURE
G-001 GENERAL INFORMATION
G-002 PROJECT SCOPE OVERALL FLOOR PLANS
G-040 GENERAL MEETING ROOM FINISH SCHEDULE
G-120 TYPICAL WALL DETAILS
G-140 MISCELLANEOUS DETAILS
A21-000 MEETING ROOM S321 SCOPE LOCATION PLAN
A21-100 MEETING ROOM S321 SELECTIVE DEMOLITION - FLOOR PLAN,
CEILING PLAN, ELEVATION
A21-200 MEETING ROOM S321 - FLOOR PLAN, REFLECTED CEILING PLAN &
FINISH PLAN
A21-300 MEETING ROOM S321 - ELEVATIONS
STRUCTURAL
S-G-001 STRUCTURAL GENERAL NOTES
S-G-002 STRUCTURAL GENERAL NOTES
S-G-003 THRESHOLD INSPECTION PLAN
S21-200 MEETING ROOM S321 FRAMING PLANS
MECHANICAL
M-G-001 SOUTH MECHANICAL SYMBOLS, LEGEND, NOTES AND INDEX
M-G-300 SOUTH MECHANICAL DETAILS
M-G-400 SOUTH MECHANICAL CONTROLS
M21-100 MEETING ROOM S321 SELECTIVE DEMOLITION - MECHANICAL FLOOR
PLAN DEMOLITION
M21-200 MEETING ROOM S321 ENLARGED FLOOR PLAN
M21-500 MEETING ROOM S321 MECHANICAL SCHEDULES
ELECTRICAL
E-G-001 SOUTH ELECTRICAL SYMBOLS AND NOTES
E-G-100 SOUTH CONCOURSE AND MEZZANINE OVERALL PLANS
E-G-701 SOUTH ELECTRICAL DETAILS
E21-100 MEETING ROOM S321 SELECTIVE DEMOLITION - ELECTRICAL FLOOR
PLAN DEMOLITION
E21-101 MEETING ROOM S321 SELECTIVE DEMOLITION - ELECTRICAL CEILING
PLAN DEMOLITION
E21-200 MEETING ROOM S321 - ELECTRICAL FLOOR PLAN
E21-201 MEETING ROOM S321 - ELECTRICAL CEILING PLAN
LIGHTING
L-G-061 LUMINAIRE SCHEDULE
L-G-099 CONTROLS NARRATIVE
L-G-111 TYPICAL CONCOURSE LIGHTING DETAILS
L-G-112 TYPICAL MEZZANINE LIGHTING DETAILS
LD21-062 DIMMER SCHEDULE
LD21-201 MEETING ROOM S321 ENLARGED CEILING PLANS
Orange County Convention Center North South Building Meeting Rooms Renovation (CIP-0965-27)
PACKAGE 21 - MEETING ROOM S321
CONSTRUCTION DOCUMENTS
Project Location: 9899 International Dr, Orlando, FL 32819 Owner of Location: Orange County BCC - Orange County Convention Center
PARCEL: 01-24-28-0000-00007
Section-01, Township-24, Range 28 District of Project – District 6
THIS PACKAGE
NO. REVISIONS / SUBMISSIONS DATE
ISSUED FOR PERMIT 09/09/2024
1 OWNER COMMENTS 09/20/2024
ISSUED FOR BID 09/20/2024
DRAWING CONVENTIONS MATERIALS LEGEND (SECTION) OVERALL PROJECT GENERAL NOTES PROJECT CODE INFORMATION
OCCUPANCY CLASSIFICATIONS
BUILDING DATA
WALL & CEILING FINISH CLASSIFICATION
FIRE RESISTANCE RATINGS
GRAVEL EARTH (COMPACTED FILL) EARTH (UNDISTURBED)
EARTH (UNDISTURBED) SAND RIP RAP
CAST-IN-PLACE CONCRETE
CAST STONE
ALUMINUM
PLYWOOD
ACOUSTICAL PANEL
CEILING
LIGHTWEIGHT CONCRETE
MARBLE
BRONZE / BRASS
PARTICLE BOARD
GYPSUM
PRECAST CONCRETE
STRUCTURAL CLAY TILE
STEEL
ORIENTED STRAND BOARD
NOT IN SCOPE
GROUT
ASHLAR STONE
WOOD BLOCKING
BATT INSULATION
BRICK
CUT STONE
WOOD FRAMING
(CONTINUOUS)
LOOSE FILL INSULATION
CONCRETE BLOCK
RUBBLE STONE
FINISH WOOD
RIGID INSULATION
1 GENERAL PROVISIONS / SUPPLEMENTAL CONDITIONS
1.01 “AIA A201 GENERAL CONDITIONS FOR CONSTRUCTION”, LATEST EDITION SHALL APPLY AND ARE PART OF THE CONTRACT
DOCUMENTS UNLESS OTHERWISE SET FORTH BY AGREEMENT.
1.02 CONTRACTOR SHALL COMPLY WITH THE APPLICABLE BUILDING CODES, LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION UPON THE PERFORMANCE OF THE WORK.
1.03 NOT USED
1.04 THE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS (WHICH INCLUDE BUT ARE NOT LIMITED TO THE CONSTRUCTION AGREEMENT, DRAWINGS, SPECIFICATIONS, ADDENDA AND MODIFICATIONS). THE CONTRACTOR SHALL REPORT DISCREPANCIES WITHIN OR BETWEEN THE CONTRACT DOCUMENTS TO THE ARCHITECT IN
WRITING FOR CLARIFICATION PRIOR TO IMPLEMENTING THE WORK.
1.05 CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS AND BUILDING SYSTEMS AFFECTED BY THE PROPOSED WORK, AS WELL AS EXISTING DIMENSIONS AND ELEVATIONS PRIOR TO COMMENCING WITH THE WORK.
CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF CONDITIONS THAT DEVIATE FROM THOSE INDICATED ON THE CONTRACT DOCUMENTS. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF EXISTING CONDITIONS AS
ACCEPTABLE TO PERFORM THE WORK.
1.06 THE ARCHITECT WILL NOT HAVE CONTROL OVER, CHARGE OF, OR RESPONSIBILITY FOR, THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES (INCLUDING TEMPORARY SHORING), OR FOR THE SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, SINCE THESE ARE SOLELY FOR CONTRACTOR'S RIGHTS
AND RESPONSIBILITIES UNDER THE CONTRACT DOCUMENTS.
1.07 IN THE EVENT THE CONTRACTOR ENCOUNTERS MATERIALS BELIEVED TO BE HAZARDOUS THAT HAVE NOT BEEN RENDERED HARMLESS, THE CONTRACTOR SHALL IMMEDIATELY STOP THE WORK IN THE AFFECTED AREA AND REPORT THE CONDITION TO THE OWNER IN WRITING. THE WORK IN THE AFFECTED AREA SHALL NOT BE RESUMED EXCEPT BY
WRITTEN AGREEMENT BETWEEN THE CONTRACTOR AND OWNER.
1.08 SUBMITTALS, SUCH AS SHOP DRAWINGS, SAMPLES, PRODUCT DATA, ETC, WHEN REQUIRED SHALL BE SUBMITTED BY THE CONTRACTOR FOR APPROVAL BY ARCHITECT PRIOR TO FABRICATION OR CONSTRUCTION. REVIEW AND APPROVAL OR OTHER ACTION TAKEN WILL BE ONLY FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH THE
INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE CONTRACT DOCUMENTS.
1.09 IN THE CASE WHERE SHORING IS REQUIRED, AS DETERMINED BY THE CONTRACTOR'S MEANS AND METHOD OF CONSTRUCTION OR OTHERWISE REQUIRED BY THE CONTRACT DOCUMENTS, CONTRACTOR SHALL PROVIDE SUCH SHORING WHICH SHALL BE ENGINEERED BY A STRUCTURAL ENGINEER CONTRACTED TO THE CONTRACTOR AND
LICENSED TO PRACTICE IN THE STATE WHERE THE PROJECT IS LOCATED.
1.10 SITE SHALL BE CLEANED THROUGHOUT THE DURATION OF THE PROJECT. REMOVE DUST, DEBRIS, OIL, STAINS, FINGERPRINTS AND LABELS FROM EXPOSED FINISHED SURFACES, INCLUDING GLAZING. CONTRACTOR SHALL BE
RESPONSIBLE FOR THEIR OWN TRASH REMOVAL DURING CONSTRUCTION.
1.11 CONTRACTOR SHALL COORDINATE AND OBTAIN APPROVAL FROM THE GOVERNING JURISDICTION(S) AND AGENCY(S) FOR SPRINKLER AND FIRE SUPPRESSION SYSTEMS THROUGHOUT CONSTRUCTION. THIS INCLUDES, BUT IS NOT LIMITED TO, REQUIREMENTS FOR TEMPORARY MEASURES DURING CONSTRUCTION TO SATISFY THE SAFETY REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION AND SHALL BE PROVIDED WITHIN THE COST OF THE WORK AT NO ADDITIONAL
COST TO THE OWNER.
1.12 THREE DIMENSIONAL REPRESENTATIONS, PHYSICAL MODELS, ANIMATIONS, PERSPECTIVE VIEWS, AND RENDERINGS ARE PROVIDED FOR REFERENCE TO ASSIST THE CONTRACTOR IN UNDERSTANDING THE DESIGN CONCEPT FOR ARCHITECTURAL COMPONENTS AND ARE NOT INTENDED TO SUPERSEDE INFORMATION CONTAINED IN OTHER CONTRACT DOCUMENTS RELATING TO THIS WORK. ISSUES REQUIRING CLARIFICATION AND/OR INTERPRETATION OF THESE
PERSPECTIVE VIEWS SHALL BE DIRECTED TO THE ARCHITECT.
2 DRAWINGS
2.01 DO NOT SCALE DRAWINGS.
2.02 ON THE DRAWINGS, AREAS THAT ARE OUT OF SCOPE ARE INDICATED WITH A GRAY TONE. (REFER TO DRAWING LEGENDS), ADDITIONAL CONSTRUCTION BEYOND THIS AREA MAY BE REQUIRED TO ADJUST EXISTING CONDITIONS AND/OR EXISTING BUILDING SYSTEMS IN ORDER FOR THE NEW CONSTRUCTION TO BE ACCOMPLISHED. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK NECESSARY TO PERFORM THE NEW CONSTRUCTION WORK DESCRIBED IN
THE CONTRACT DOCUMENTS.
2.03 THREE DIMENSIONAL (3D) PERSPECTIVE VIEWS MAY BE PROVIDED FOR REFERENCE TO ASSIST THE CONTRACTOR IN UNDERSTANDING THE DESIGN CONCEPT FOR CERTAIN COMPONENTS. AS SUCH, THESE VIEWS ARE DIAGRAMMATIC IN NATURE AND ALL INFORMATION FOR CONSTRUCTION MAY NOT BE ILLUSTRATED IN THE PERSPECTIVE VIEW.
CLARIFICATIONS AND / OR INTERPRETATIONS RELATING TO PERSPECTIVE VIEWS SHALL BE DIRECTED TO THE ARCHITECT
PRIOR TO CONSTRUCTION.
2.04 BUILDING COMPONENTS AND/OR PORTIONS OF SYSTEMS AS MAY BE INDICATED ON THE ARCHITECTURAL DRAWINGS SUCH AS LIGHT FIXTURES, AIR DIFFUSERS/RETURNS, SPRINKLERS AND SPEAKERS, ETC ARE GENERALLY SHOWN TO DENOTE LOCATION AND LAYOUT PATTERN WHERE PLACEMENT IS CRITICAL TO APPEARANCE. THE ARCHITECTURAL DRAWINGS DO NOT REPRESENT COMPLETE SYSTEMS WHICH ARE TO BE PROVIDED AND AS MAY BE REQUIRED BY OTHER
CONTRACT DOCUMENTS.
2.05 “MATCH EXISTING” AND “MATCH ADJACENT” MEANS TO EXACTLY MATCH THE EXISTING OR ADJACENT ITEM INCLUDING
APPEARANCE, MANUFACTURER, FINISH, PRODUCT, CONFIGURATION AND INSTALLATION.
2.07 ITEMS NOTED AS “TYPICAL” OR "TYP” MEANS TO APPLY TO OTHER, SIMILAR LOCATIONS.
2.08 ITEMS NOTED AS “SIMILAR” OR “SIM” MEANS THAT A COMPONENT OR DETAIL CONDITION IS SIMILAR IN DESIGN INTENT AND FINISH TO THE REFERENCED DETAIL BUT MAY VARY IN DIMENSION, LOCATION OR ORIENTATION.
3 EXISTING BUILDING DRAWINGS
3.01 IN THE PREPARATION OF THE DRAWINGS, THE ARCHITECT AND ENGINEERS HAVE UTILIZED AND RELIED UPON THE
FOLLOWING AVAILABLE INFORMATION:
ORIGINAL DRAWINGS OF EXISTING CONSTRUCTION AS PREPARED BY HHCP AND DATED 02.01.01.
3.02 CONTRACTOR MAY NOT RELY SOLELY UPON THE COMPLETENESS OF EXISTING DRAWINGS. THE CONTRACTOR IS RESPONSIBLE TO BECOME FAMILIAR WITH EXISTING BUILDING INFORMATION AS MAY BE MADE AVAILABLE BY THE OWNER (SUCH AS ARCHITECTURAL AND ENGINEERING DRAWINGS) AND THE EXISTING PHYSICAL CONDITIONS ON, OR RELATING TO, THE SITE AND BUILDING. CONTRACTOR SHALL VERIFY THESE CONDITIONS FOR BIDDING AND CONSTRUCTION
PURPOSES.
3.03 CONTRACTOR TO REVIEW THE EXISTING BUILDING DRAWINGS FOR EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION OR DEMOLITION. CONTACT LOCAL UTILITY COMPANIES FOR UTILITY MARKINGS PRIOR TO COMMENCEMENT OF DEMOLITION WORK. REVIEW UTILITY LOCATIONS WITH OWNER’S ENGINEERING STAFF PRIOR TO COMMENCEMENT OF DEMOLITION
WORK.
4 SPECIAL PROJECT PROCEDURES / TEMPORARY MEASURES
4.01 BASED ON THE CONTRACTOR’S “MEANS AND METHODS” FOR CONSTRUCTION, CONTRACTOR SHALL DETERMINE INTERMEDIATE STAGING AND SEQUENCING OF DEMOLITION, TEMPORARY WORK AND NEW WORK TO ENSURE CONTINUOUS AND SAFE OCCUPANCY OF EXISTING FACILITY – WHILE MAINTAINING NORMAL OPERATIONS. THE CONTRACTOR SHALL PREPARE AND SUBMIT FOR ACCEPTANCE A PHASING AND SEQUENCING PLAN TO THE OWNER PRIOR
TO THE START OF CONSTRUCTION.
4.02 ALL LIFE SAFETY SYSTEMS, EXITING AND TENANT SERVICES ARE TO BE MAINTAINED THROUGHOUT DEMOLITION AND CONSTRUCTION WORK – INCLUDING, BUT NOT LIMITED TO, EGRESS PATHWAYS, FIRE ALARM, FIRE SUPPRESSION, EMERGENCY POWER, MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, BUILDING CONTROL SYSTEMS AND BUILDING UTILITY SERVICES / SYSTEMS. IF THE CONTRACTOR PROPOSES TO INTERRUPT ANY OF THESE SYSTEMS, THE CONTRACTOR SHALL PROVIDE NOTICE, OBTAIN APPROVAL, PROVIDE TEMPORARY MEASURES, SECURITY AND/OR FIRE PROTECTION SERVICES DURING THE INTERRUPTION IN ACCORDANCE WITH THE REQUIREMENTS OF THE OWNER AND
LOCAL JURISDICTION OF CODE ENFORCEMENT.
4.03 IN PLANNING AND SEQUENCING THE WORK, CONTRACTOR SHALL MAINTAIN AND PROTECT AT ALL TIMES THE CLEAR ACCESS TO CAPACITY, LIGHTING, AND SIGNAGE OF ALL MEANS OF EGRESS FOR THE FACILITY THAT ARE AFFECTED BY
DEMOLITION AND/OR CONSTRUCTION.
4.04 CONTRACTOR SHALL PROVIDE ALL TEMPORARY CONSTRUCTION NECESSARY TO ACCOMPLISH THE WORK AND AVOID INTERRUPTION TO ANY AND ALL OTHER BUILDING FUNCTIONS, SERVICES AND SYSTEMS THAT MAY BE AFFECTED BY THE
DEMOLITION AND/OR CONSTRUCTION.
4.05 ADDITIONAL CONSTRUCTION OR MAINTENANCE MAY BE ONGOING IN OTHER PARTS OF THE BUILDING. THE CONTRACTOR IS TO COORDINATE HIS WORK WITH THE OWNER’S DESIGNATED REPRESENTATIVE AND WITH OTHER CONSTRUCTION OR
MAINTENANCE TEAMS SO AS TO AVOID CONSTRUCTION DELAYS.
4.06 THE CONTRACTOR SHALL COORDINATE HIS WORK WITH BUILDING'S SECURITY, OPERATIONS, MANAGEMENT, AND
LANDLORD.
4.07 CONTRACTOR SHALL PROVIDE AND MAINTAIN PROTECTIVE MEASURES IN ALL AREAS OF DEMOLITION AND
CONSTRUCTION TO PREVENT ANY WATER INFILTRATION.
4.08 TEMPORARY EXTERIOR AND INTERIOR ENCLOSURES SHALL BE PROVIDED AS DETERMINED NECESSARY BY CONTRACTOR BASED ON CONTRACTOR’S “MEANS AND METHODS” FOR CONSTRUCTION. THESE ENCLOSURES SHALL BE SECURE, STRUCTURALLY SOUND, WATERTIGHT AND THERMALLY INSULATED.
4.09 CONTRACTOR TO PROVIDE TEMPORARY AND CODE COMPLIANT RAMPS, BARRICADES, WALKWAYS, FLOORING TRANSITIONS, AND OTHER MEASURES AS DETERMINED NECESSARY BY THE CONTRACTOR'S "MEANS AND METHODS" FOR CONSTRUCTION. THESE MEASURES SHALL BE MAINTAINED TO PROTECT THE GENERAL PUBLIC'S ACCESS TO CLEAR CIRCULATION PATHS AND TO PROVIDE ACCESS TO AND EGRESS FROM THE BUILDING DURING DEMOLITION AND
CONSTRUCTION.
4.10 CONTRACTOR SHALL OBTAIN APPROVAL FOR ALL TEMPORARY WALKWAYS/EXITS FROM THE LOCAL JURISDICTION OF CODE ENFORCEMENT. COORDINATE DEMOLITION OF BUILDING ENTRANCES, STRUCTURES AND STOREFRONT SYSTEMS WITH OWNER. PROVIDE NECESSARY BARRICADES AND COVERED ENTRANCE ROOF AREAS AND/OR ENCLOSED “TUNNEL”
STRUCTURES TO ACCOMMODATE NORMAL BUILDING INGRESS AND EGRESS AT ALL TIMES.
4.11 NOTIFY OWNER (AND/OR OWNER’S DESIGNATED REPRESENTATIVE) PRIOR TO COMMENCEMENT OF ALL ELECTRICAL, MECHANICAL, PLUMBING AND FIRE PROTECTION WORK. OBTAIN OWNER’S AUTHORIZATION ONE (1) WEEK IN ADVANCE FOR ANY DISRUPTION OF SERVICES. IN NO CASE SHALL DISRUPTION OF SERVICES OCCUR IN OWNER-OCCUPIED/TENANT-
OCCUPIED AREAS.
4.12 CONSTRUCTION STAGING AREA TO BE COORDINATED WITH AND APPROVED BY OWNER. CONTRACTOR’S PROPOSED PLAN
FOR PARKING OF WORKERS SHALL BE COORDINATED WITH AND APPROVED BY THE OWNER.
4.13 TEMPORARY INTERIOR BARRIERS SHALL BE MAINTAINED AT ALL TIMES TO PREVENT MIGRATION OF CONTAMINANTS TO
OCCUPIED AREAS INCLUDING BUT NOT LIMITED TO DUST, FUMES, SMOKE, ODORS, ETC..
5 DEMOLITION
5.01 DEMOLITION DRAWINGS GENERALLY DESCRIBE THOSE PORTIONS OF THE EXISTING CONDITIONS WHICH ARE TO BE REMOVED AND/OR SALVAGED. THESE DRAWINGS DO NOT NECESSARILY DESCRIBE ALL DEMOLITION THAT WILL BE REQUIRED IN ORDER TO CONSTRUCT THE NEW WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION OF ALL PORTIONS OF EXISTING CONDITIONS NECESSARY TO CONSTRUCT AND COORDINATE THE NEW WORK SHOWN ON THE DRAWINGS. IF CONTRACTOR IS UNCERTAIN WHETHER AN EXISTING ELEMENT IS TO BE REMOVED, THE CONTRACTOR SHOULD GET WRITTEN GUIDANCE/APPROVAL FROM THE ARCHITECT OF RECORD
BEFORE PROCEEDING.
5.02 DEMOLITION WORK AFFECTING ADJACENT PROPERTY, ADJACENT BUILDINGS, EXISTING TENANTS AND/OR OTHER OCCUPIED PORTIONS OF THE BUILDING MUST BE COORDINATED WITH THE OWNER (OR DESIGNATED OWNER’S REPRESENTATIVE). WORK AFFECTING ADJACENT, OCCUPIED AREAS SHALL COMMENCE ONLY WITH PROPER
AUTHORIZATION BY THE OWNER.
5.03 CONTRACTOR TO COORDINATE WITH ARCHITECTURAL, STRUCTURAL AND MEP DOCUMENTS FOR ALL DEMOLITION WORK, INCLUDING OPENINGS AND PENETRATIONS FOR REQUIRED SCOPE OF WORK AND DIMENSIONS PRIOR TO
PROCEEDING WITH DEMOLITION WORK.
5.04 UNLESS OTHERWISE NOTED, NUMERICAL DESIGNATIONS IN THE DEMOLITION DRAWINGS ARE NOT INTENDED TO
IMPLY A SEQUENCE OF CONSTRUCTION AND/OR DEMOLITION.
5.05 CONTRACTOR TO NOTIFY ARCHITECT IF THERE ARE UNFORESEEN STRUCTURAL MEMBERS, MISCELLANEOUS
OBJECTS AND/OR UNIDENTIFIED UTILITY LINES ENCOUNTERED DURING DEMOLITION.
5.06 PROVIDE TEMPORARY SUPPORT OF WORK TO BE CUT/REMOVED.
5.07 ALL SALVAGE MATERIALS SELECTED BY THE OWNER AND/OR INDICATED IN THE CONTRACT DOCUMENTS FOR SALVAGE AND/OR REUSE SHALL BE PROTECTED AND STORED IN AN AREA (ON SITE) AS DESIGNATED BY THE OWNER. THE FOLLOWING ITEMS SHALL BE SALVAGED FOR REUSE: LIGHT FIXTURES; EXIT SIGNS; THERMOSTATS;
FIRE ALARM DEVICES AND STROBES; MECHANICAL CEILING GRILLES AND DIFFUSERS; FIRE EXTINGUISHERS AND
CABINETS; SMOKE DETECTORS; RETURN AIR TRANSFER DUCTS; DOORS/HARDWARE.
5.08 WHERE EXISTING MATERIALS ARE TO BE REMOVED, ANY MATERIAL ADHESIVES, ATTACHMENTS OR SUPPORTS ARE TO BE REMOVED AS WELL IN ORDER TO PROVIDE A SUBSTRATE EQUAL IN CONDITION TO A SIMILAR NEW SUBSTRATE. CONTRACTOR IS RESPONSIBLE FOR ANY CUTTING, PATCHING, AND PREPARATION OF SUBSTRATE
REQUIRED IN ORDER TO RECEIVE NEW FINISHES.
5.09 PROTECT EXISTING CONSTRUCTION DURING DEMOLITION, CUTTING AND PATCHING TO PREVENT DAMAGE.
PROVIDE PROTECTION FROM ADVERSE ENVIRONMENTAL CONDITIONS.
5.10 CONTRACTOR SHALL EXAMINE AREAS WHERE DEMOLITION OR CUTTING AND PATCHING ARE REQUIRED, TAKING INTO CONSIDERATION CONDITIONS UNDER WHICH OPERATIONS ARE PERFORMED AND CAREFULLY PLANNING OPERATIONS TO INSURE SUCCESSFUL RESULTS IN COORDINATION WITH NEW CONSTRUCTION AND ADJACENT
EXISTING CONDITIONS.
5.11 DO NOT REMOVE, CUT AND/OR PATCH OPERATIONAL ELEMENTS AND RELATED COMPONENTS IN A MANNER THAT RESULTS IN REDUCING THEIR CAPACITY TO PERFORM AS INTENDED OR THAT RESULTS IN INCREASED
MAINTENANCE OR DECREASED OPERATIONAL LIFE OR SAFETY.
5.12 DO NOT REMOVE, CUT AND/OR PATCH IN A MANNER THAT RESULTS IN VISUAL EVIDENCE OF CUTTING OR PATCHING. DO NOT REMOVE, CUT AND/OR PATCH COMPONENTS EXPOSED ON THE EXTERIOR OR IN OCCUPIED SPACES IN A MANNER THAT WOULD REDUCE THE BUILDING’S AESTHETIC, FUNCTIONAL QUALITIES. CONSTRUCTION THAT HAS BEEN REMOVED, CUT AND/OR PATCHED IN A VISUALLY UNSATISFACTORY MANNER SHALL BE
CORRECTED.
5.13 BEFORE PATCHING, CONTRACTOR TO VERIFY COMPATIBILITY WITH AND SUITABILITY OF SUBSTRATES – INCLUDING COMPATIBILITY WITH EXISTING FINISHES OR PRIMERS. PROCEED WITH INSTALLATION ONLY AFTER
UNSATISFACTORY CONDITION HAS BEEN ADDRESSED AND/OR REMEDIATED.
5.14 CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ANY EXISTING BUILDING COMPONENTS DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES. DAMAGED COMPONENTS TO REMAIN SHALL BE REPAIRED
TO MATCH ADJACENT EXISTING CONSTRUCTION OR NEW FINISHES.
6 MATERIALS, SYSTEMS AND COMPONENTS
6.01 ALL MATERIALS, SYSTEMS, FINISHES AND COMPONENTS SHALL BE PROVIDED AS INDICATED IN THE CONTRACT DOCUMENTS. PREPARE AND SUBMIT SUBMITTALS FOR REVIEW IN A TIMELY MANNER, ALLOWING ADEQUATE TIME FOR ARCHITECT'S REVIEW AND IN SUPPORT OF THE CONSTRUCTION SCHEDULE. DO NOT PROCEED WITH
PROCUREMENT OR FABRICATION OF WORK PRIOR TO APPROVAL BY ARCHITECT.
6.02 SUBSTITUTION REQUIREMENTS: REQUESTS FOR SUBSTITUTIONS, IF ALLOWED BY OWNER, SHALL BE SUBMITTED BY THE CONTRACTOR AS A REQUEST FOR CONSIDERATION BY THE OWNER IN A FORM ACCEPTABLE TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. INCLUDE A DETAILED COMPARISSON OF SIGNIFICANT QUALITIES OF PROPOSED SUBSTITUTION WITH THOSE OF THE WORK SPECIFIED, A LIST OF CHANGES NEEDED TO OTHER PARTS OF THE WORK REQUIRED TO ACCOMMODATE PROPOSED SUBSTITUTIONS, AND ANY PROPOSED
CHANGES IN THE CONTRACT SUM OR THE CONTRACT TIME.
6.03 CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTAL MATERIAL REQUIRED TO PROPERLY INSTALL, SUPPORT AND
BRACE ALL COMPONENTS OF THE WORK.
6.04 CONTRACTOR SHALL VERIFY AND COORDINATE CONDITIONS AND DIMENSIONS BEFORE FABRICATION OF ANY
WORK.
6.05 ALL FASTENERS AND ATTACHMENTS IN AREAS TO BE OCCUPIED BY THE PUBLIC SHALL BE FULLY CONCEALED
FROM VIEW, UNLESS OTHERWISE NOTED.
6.06 PROVIDE FIRE-RETARDANT WOOD BLOCKING OR STEEL REINFORCING AS REQUIRED IN PARTITIONS AND IN CEILINGS TO SUPPORT MILLWORK, LIGHT FIXTURES, ACCESSORIES, ARTWORK, HARDWARE, HANDRAILS AND/OR
OTHER APPLIED FINISH SYSTEMS.
7 FINISHES
7.01 CONTRACTOR SHALL PROVIDE MEANS TO LEVEL AND/OR REPAIR FLOORING SUBSTRATE TO RECEIVE NEW FINISH FLOORING IN ALL AREAS WHERE DEMOLITION OF EXISTING TILE, PARTITIONS, CARPETING, ETC CAUSES AND/OR EXPOSES UNEVENNESS IN THE FLOOR OR SLAB. CONTRACTOR TO SELECT REPAIR MATERIALS AND USE PROCEDURES TO BE COMPATIBLE WITH MANUFACTURER'S REQUIREMENTS FOR NEW FINISH FLOORING SYSTEMS.
7.02 PATCH CONSTRUCTION BY FILLING, PREPARING, REFINISHING, CLOSING UP AND SIMILAR OPERATIONS FOLLOWING PERFORMANCE OF OTHER WORK. PATCH WITH DURABLE SEAMS THAT ARE CONCEALED AND NOT VISIBLE. TEST AND INSPECT PATCHED AREAS AFTER COMPLETION TO VERIFY/DEMONSTRATE INTEGRITY OF INSTALLATION.
7.03 RESTORE FINISHES OF PATCHED AREAS AND EXTEND FINISH RESTORATION INTO ADJOINING CONSTRUCTION IN A
MANNER THAT WILL CONCEAL VISIBLE EVIDENCE OF PATCHING AND REFINISHING.
7.04 WHERE WALLS OR PARTITIONS THAT ARE REMOVED EXTEND FROM ONE FINISHED AREA INTO ANOTHER, PATCH AND REPAIR FLOOR AND WALL SURFACES IN THE NEW SPACE. PROVIDE AN EVEN SURFACE OF UNIFORM FINISH, COLOR, TEXTURE AND APPEARANCE. REMOVE EXISTING FLOOR AND WALL COVERINGS AND REPLACE WITH NEW
MATERIALS, IF NECESSARY, TO ACHIEVE UNIFORM COLOR AND APPEARANCE.
7.05 WHERE PATCHING OCCURS IN A PAINTED SURFACE, APPLY PRIMER AND INTERMEDIATE PAINT COATS OVER THE PATCH AND SUPPLY FINAL PAINT COAT OVER THE ENTIRE UNBROKEN SURFACE CONTACTING THE PATCH.
PROVIDE ADDITIONAL COATS UNTIL PATCH BLENDS WITH ADJACENT SURFACE.
7.06 PATCH, REPAIR OR REHANG CEILINGS AS NECESSARY TO PROVIDE AN EVEN-PLANE SURFACE OR UNIFORM APPEARANCE. REPLACE ALL CEILING TILES FROM WHICH DEVICES OR FIXTURES HAVE BEEN REMOVED OR
REPLACED.
7.07 MATERIALS USED FOR INTERIOR WALLS, CEILINGS AND TRIM SHALL BE CLASS A FIRE RATED UNLESS OTHERWISE
NOTED.
7.08 INSTALL FINISH MATERIALS IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDED SPECIFICATIONS, ENVIRONMENTAL CONDITIONS, SURFACE PREPARATIONS, ADHESIVES, COMPATIBILITY WITH ADJACENT
MATERIALS, BACKINGS, ETC
7.09 ELECTRICAL SWITCH AND COVER PLATES, SURFACE HARDWARE, GRILLES, ETC SHALL BE INSTALLED AFTER
PAINTING AND/OR APPLICATION OF WALL/FLOOR COVERINGS.
7.10 SLIP RESISTANCE TESTING: PRIOR TO SUBSTANTIAL COMPLETION, CONTRACTOR SHALL ENGAGE AN EXPERIENCED INDEPENDENT TESTING LAB TO PERFORM DYNAMIC COEFFICIENT OF FRICTION FIELD TESTING OF EACH SMOOTH SURFACE, NON-POROUS FLOORING MATERIAL. TESTS SHALL BE PERFORMED IN ACCORDANCE WITH ANSI A137.1 USING THE BOT-3000 TESTING EQUIPMENT. MULTIPLE TESTS SHALL BE CONDUCTED WITH A REPRESENTATIVE SAMPLE OF NOT LESS THAN 3 TESTS PER FLOORING MATERIAL THAT EXCEEDS 1000 SF IN TOTAL AREA. TESTING AGENCY SHALL SUBMIT TEST REPORTS TO CONTRACTOR, ARCHITECT AND OWNER PRIOR TO REQUEST FOR SUBSTANTIAL COMPLETION. REFER TO INDIVIDUAL PRODUCT SPECIFICATIONS FOR MINIMUM REQUIRED SLIP RESISTANCE CRITERIA. IN NO CASE SHALL FLOORING HAVE A WET DCOF OF LESS THAN 0.42.
8 FIRE-RATED ASSEMBLIES
8.01 ALL WOOD BLOCKING TO BE FIRE-RETARDANT TREATED LUMBER.
8.02 CONTRACTOR SHALL RESTORE ALL EXISTING RATED FLOOR AND WALL ASSEMBLIES TO THEIR EXISTING RATING STATUS FOLLOWING DEMOLITION AND/OR MODIFICATION DURING DEMOLITION AND CONSTRUCTION.
PROVIDE THE FOLLOWING MINIMUM RATINGS UNLESS OTHERWISE INDICATED:
STRUCTURAL FLOOR ASSEMBLIES 2-HOUR CONSTRUCTION
WALLS SURROUNDING ELEVATORS 2-HOUR CONSTRUCTION
WALLS SURROUNDING STAIRS 2-HOUR CONSTRUCTION
EXIT ENCLOSURES 2-HOUR CONSTRUCTION
SHAFTS PENETRATING FLOORS 2-HOUR CONSTRUCTION
8.03 WHERE NEW RATED WALL CONSTRUCTION JOINS EXISTING RATED WALL CONSTRUCTION, CONSTRUCT WALL JOINTS AS REFERENCED IN THE WALL TYPE AND UL SYSTEM INDICATED IN THE CONTRACT DOCUMENTS. WHERE EXISTING RATED WALLS ARE INFILLED WITH NEW RATED CONSTRUCTION, CONSTRUCT NEW WALL SO THAT ENTIRE RATED WALL CONFORMS TO WALL TYPE AND UL SYSTEM INDICATED IN THE CONTRACT DOCUMENTS.
8.04 INSTALL FIRE STOPPING MATERIALS AT PENETRATIONS/OPENINGS IN FLOOR SLABS, PARTITIONS, WALLS AND CEILINGS TO MAINTAIN EXISTING/REQUIRED FIRE/SMOKE RATINGS. PENETRATION AND JOINT FIRESTOPPING SYSTEMS SHALL BE UL LISTED ASSEMBLIES. ALL WORK OF THIS TYPE WHICH MAY REQUIRE ACCESS TO TENANT AND/OR OCCUPIED AREAS OF THE BUILDING WHICH ARE NOT LOCATED WITHIN THE SCOPE OF WORK FOR THIS
PROJECT SHALL BE SCHEDULED WITH BUILDING OWNER AND TO OCCUR DURING OFF-HOURS.
FINISH CLASSIFICATION
USE GROUP EXIT ENCLOSURES CORRIDORS
B
S
ROOMS
B
C C C
CC
(REFERENCE FBC TABLE 803.11)
PRIMARY CLASSIFICATION: ASSEMBLY - GROUP A-3 (EXISTING)
CLASSIFICATION
(FBC - CHAPTER 3, LSC - CHAPTER 6)
FUNCTION
(FBC - TABLE 1004.1.1)
OCCUPANT LOAD FACTOR
(FBC - TABLE 1004.5; LSC, TABLE 7.3.1.2)
ASSEMBLY WITHOUT FIXED SEATS UNCONCENTRATED,
TABLES & CHAIRS
15 SF PER PERSON - NET
BUSINESS, B GENERAL OPEN
OFFICE
150 SF PER PERSON - GROSS
STORAGE, S-2 PARKING DECKS 300 SF PER PERSON - GROSS
CONSTRUCTION TYPE: TYPE 1A (EXISTING)
SPRINKLERS:
(FBC - SECTION 903, LSC - SECTION 9.7.1)
STANDPIPES:
(FBC - SECTION 905.3, LSC - SECTION 9.10)
YES
YES
NFPA 13 SUPERVISED
WETNFPA 14
FIRE DISTRICT: YES
HIGH RISE:
(FBC SECTION 403)
NO
MEZZANINE:
(FBC SECTION 505)
NO
FIRE ALARM:
(FBC SECTION 907.2; LSC SECTION 9.6)
YES
ORANGE COUNTY FIRE
RESCUE DEPARTMENT
AUTOMATIC
BUILDING ELEMENT - FBC TABLE 601, TYPE 1A (EXISTING)
REMARKSRATING (HRS)
PRIMARY STRUCTURAL FRAME f 3 a, b
BEARING WALLS
EXTERIOR e, f 3
INTERIOR 3 a
NONBEARING WALLS & PARTITIONS
EXTERIOR
NONBEARING WALLS & PARTITIONS
INTERIOR d 0
FLOOR CONSTRUCTION & ASSOCIATED
SECONDARY MEMBERS
ROOF CONSTRUCTION & ASSOCIATED
SECONDARY MEMBERS
1 b
FIRE SEPARATIONS
REMARKSRATING (HRS)
VERTICAL SHAFTS
(FBC 713.4):
2 SAME AS
FLOOR RTG
WALLS & PENETRATIONS:
FIRE WALLS:
(FBC TABLE 706.4)
EXITS:
HORIZONTAL EXIT:
(FBC SECTION 1026.2)
EXIT ACCESS CORRIDORS:
(FBC SECTION 1020.2)
0 WITH SPRINKLER
SYSTEM
EXIT PASSAGEWAY:
(FBC SECTION 1024.3)
INCIDENTAL USE
(REFERENCE FBC TABLE 509.1)
STORAGE (FBC SECTION 509.1):
ELEVATOR MACHINE ROOM (FBC SECTION 3005.4):
ROOM
NAME
NEW
COLUMN GRID
EXISTING
COLUMN GRID
A
BUILDING SECTION
PARTIAL BUILDING
(WALL) SECTION
A-000
A-000
A,1
A-000
A,1
C,1
A-000
A,1
A-000
A,1
A-000
A,1
SECTION MARKER
SECTION DRAWING
NUMBER
SHEET NUMBER ON
WHICH SECTION IS
DRAWN
EXTERIOR ELEVATION MARKER
ELEVATION DRAWING
NUMBER
SHEET NUMBER ON
WHICH ELEVATION IS
DRAWN
INTERIOR ELEVATION MARKER
INTERIOR ELEVATION
DRAWING NUMBER
SHEET NUMBER ON
WHICH ELEVATION IS
DRAWN
ENLARGED DETAIL REFERENCE
HOLD CLOUD
ON HOLD
PARTITION TYPE MARKER
PARTITION TYPE - SEE
FLOOR PLANS
DIMENSIONAL STANDARDS
FINISH FACE
3' - 6"
CRITICAL
DESIGNATE
DIMENSION
MARK AT GRID
ACCESORY & FIXTURE TAGS ABC FOR ACCESSORIES
FLOOR ELEVATION SYMBOL
NAME
ELEVATION
0'-0" 0'-0"
NAME
ELEVATION
PROPOSED EXISTING
SPOT ELEVATION SYMBOL
PROPOSED EXISTING
REVISION CLOUD
REVISION CLOUD
1 2
REVISION NUMBER
ASI-000
DOOR NUMBER
WINDOW & LOUVER
TYPE
COLUMN MARKER
ROOM TAG
DETAIL DRAWING NUMBER
SHEET NUMBER
("HOLD", "ROUGH OPENING", "MAINTAIN CLEAR", ETC.)
CL
PARTITION TYPE
SIZE
MODIFICATION 1
MODIFICATION 2
A10 c 0 S S
RATING
(SECTION/ELEVATION)
(PLAN)
ADDITIONAL ISSUANCE
INFORMATION WHEN
DESIRED
(RFI-000)
(BULLETIN - 00)
SPACE NO.
DOOR W/IN SPACE
ROOM NUMBER
C ,1
DRAWING TITLE & NUMBER
E, 1
1/4" = 1' - 0"
FRAME TYPES
ALPHA DESIGNATION = X
COORDINATE GRID
NUMERIC DESIGNATION = Y
COORDINATE GRID
DRAWING TITLE
DRAWING SCALE
N
J
E
A
1 3 5 7 9 11
NUMERIC DESIGNATION = Y
COORDINATE GRID
Notes:
DRAWING NOTES
DRAWING NUMBER
SHEET
DRAWING AREA
CLEAR
3' - 0"
FINISH FACE
CENTER LINE
CLEAR
TICK MARK TYPES
N/A
2 SAME AS SHAFT
ASSEMBLY WITHOUT FIXED SEATS CONCENTRATED 7 SF PER PERSON - NET
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
Footnotes:
a) Roof supports: Fire-resistance ratings of primary structural frame and bearing walls are permitted to be reduced by 1 hour where supporting a roof only.
b) Where every part of the roof construction is 20 feet or more above the floor or mezzanine immediately below, fire protection of structural members in roof construction shall not be required, including protection of primary structural frame members, roof framing and decking.
d) Not less than the fire-resistance rating required by other sections the Florida Building Code.
e) Not less than the fire-resistance rating based on fire separation distance (see Table 705.5).
f) Not less than the fire-resistance rating as referenced in Section 704.10.
*) Rating of exterior walls varies around the building based on existing record drawings. Existing rated walls will be maintained and are indicated on floor plans where this project impacts these conditions.
VARIES *
SHEET NUMBER
442 W Kennedy Blvd Suite 312 Tampa Florida 33606 tvsdesign.com
SHEET TITLE
SEAL
987654321
B
A
D
C
TVS PROJECT NUMBER
F
E
H
G
J
K
B
A
D
C
F
E
H
G
J
K
987654321
TVS FLORIDA, INC., ARCHITECTURE
Scales as stated hereon are valid on the original drawing, the dimensions of which are 30x42 inches. These scales noted hereon are hereby changed by the ratio of the overall sheet dimensions of the print to the corresponding dimensions of the original drawing.
© TVS FLORIDA, INC., ARCHITECTURE
This drawing is the property of TVS FLORIDA, INC., ARCHITECTURE and is not to be reproduced or copied in whole or in part. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
M
L
N
M
L
N
RELEASED FOR CONSTRUCTION
ORIGINAL ISSUE DATE
P P
605 E. ROBINSON STREET, SUITE 750 ORLANDO, FL 32801
407.648.7288 www.rbarchitects.com AR0014284
9/
/2
:1 8:
A
M A ut od es k
D oc s:
//P
-2
O ra ng e
C ou nt y
C on ve nt io n
C en te r/
P -2
_A R
C H
_I nt er io r.
rv t
G-001
GENERAL INFORMATION
9899 International Dr, Orlando, FL 32819
P-20257
09/09/24
09/09/2024
OCCC NORTH SOUTH BUILDING
MEETING ROOMS RENOVATION
NO. REVISIONS / SUBMISSIONS DATE
ISSUED FOR PERMIT 09/09/2024
MI D L A N DI N G
13 1' -0 "
ME Z Z A N I N E L E V E L
14 2' -0 "
12 12 11
(2) 8" DIA. PIPE SLEEVES
31" x 23.75" HOLE
(2) 8" DIA. PIPE SLEEVES
31" x 23.75" HOLE
GRAPHIC LEGEND
S E S ES E S E
S K
S K
'-8
'-1
3 _ 4
'-8
'-1
3 _ 4
19 ' -7" 4 ' -1"
NE
NJ
NO
NT
NY
NCC
SB
SG
SL
SQ
SV
AAA
1 5 10 15 20 25 30 35 40 45
PACKAGE 04
MEETING ROOM N310
PACKAGE 16
MEETING ROOM S310
PACKAGE 17
MEETING ROOM S311
PACKAGE 18
MEETING ROOM S312
PACKAGE 19
MEETING ROOM S319
PACKAGE 20
MEETING ROOM S320
PACKAGE 24
MEETING ROOM S330
PACKAGE 25
MEETING ROOM S331
PACKAGE 21
MEETING ROOM S321
PACKAGE 22
MEETING ROOM S322
PACKAGE 23
MEETING ROOM S329
PACKAGE 06
MEETING ROOM N312
PACKAGE 05
MEETING ROOM N311
PACKAGE 08
MEETING ROOM N320
PACKAGE 07
MEETING ROOM N319
D
C
B
A
H
G
F
E
C O
R R
ID
O
R
D
C
B
A
H
G
F
E
C O
R R
ID
O
R
D
C
B
A
A
B
C
D
E
F
G
H
C O
R R
ID
O
R
A
B
C
D
E
F
G
H
C O
R R
ID
O
R
A
B
C
D
E
F
G
H
C O
R R
ID
O
R
A
B
C
D
PACKAGE 10
MEETING ROOM N322
PACKAGE 09
MEETING ROOM N321
PACKAGE 11
MEETING ROOM N329
PACKAGE 12
MEETING ROOM N330
NOT IN SCOPE
PROJECT SCOPE
NE
NJ
NO
NT
NY
NCC
SB
SG
SL
SQ
SV
AAA
1 5 10 15 20 25 30 35 40 45
PACKAGE 01
MEETING ROOM N210
PACKAGE 02
MEETING ROOM N220
PACKAGE 03
MEETING ROOM N230
PACKAGE 13
MEETING ROOM S210
PACKAGE 14
MEETING ROOM S220
PACKAGE 15
MEETING ROOM S230
A B C D E F GA B C D E A B C D E F G H
A B C D E A B C D E F G A B
SHEET NUMBER
442 W Kennedy Blvd Suite 312 Tampa Florida 33606 tvsdesign.com
SHEET TITLE
SEAL
987654321
B
A
D
C
TVS PROJECT NUMBER
F
E
H
G
J
K
B
A
D
C
F
E
H
G
J
K
987654321
TVS FLORIDA, INC., ARCHITECTURE
Scales as stated hereon are valid on the original drawing, the dimensions of which are 30x42 inches. These scales noted hereon are hereby changed by the ratio of the overall sheet dimensions of the print to the corresponding dimensions of the original drawing.
© TVS FLORIDA, INC., ARCHITECTURE
This drawing is the property of TVS FLORIDA, INC., ARCHITECTURE and is not to be reproduced or copied in whole or in part. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
M
L
N
M
L
N
RELEASED FOR CONSTRUCTION
ORIGINAL ISSUE DATE
P P
605 E. ROBINSON STREET, SUITE 750 ORLANDO, FL 32801
407.648.7288 www.rbarchitects.com AR0014284
9/
/2
:1 8:
A
M A ut od es k
D oc s:
//P
-2
O ra ng e
C ou nt y
C on ve nt io n
C en te r/
P -2
_A R
C H
_I nt er io r.
rv t
G-002
PROJECT SCOPE OVERALL FLOOR PLANS
9899 International Dr, Orlando, FL 32819
P-20257
09/09/24
09/09/2024
OCCC NORTH SOUTH BUILDING
MEETING ROOMS RENOVATION
1" = 100'-0" -
A,1 OVERALL FLOOR PLAN - MEZZANINE LEVEL
1" = 100'-0" -
A,6 OVERALL FLOOR PLAN - CONCOURSE LEVEL
NO. REVISIONS / SUBMISSIONS DATE
FINISH GENERAL NOTES
A. PAINT INTERIOR MISCELLANEOUS METAL, GRILLES, LOUVERS, ACCESS PANELS, PIPES AND CONDUIT
EXPOSED TO PUBLIC VIEW TO MATCH THE WALLS ON WHICH THEY OCCUR.
B. SURFACE TYPES SHALL HAVE THE FOLLOWING PAINT FINISHES UNLESS OTHERWISE NOTED:
1. CEILINGS: FLAT
2. GYPSUM WALLBOARD PARTITIONS: EGGSHELL
3. CONCRETE UNIT MASONRY: SEMI GLOSS
4. METAL TRIM, DOOR FRAMES AND DOORS: SEMI GLOSS
C. EXPOSED GYPSUM WALLBOARD SURFACES SHALL RECEIVE PAINT UNLESS OTHERWISE NOTED.
CONFIRM PAINT DESIGNATIONS WITH ARCHITECT WHERE NOT INDICATED ON THE DRAWINGS.
D. PAINT REVEALS TO MATCH THE WALLS IN WHICH THEY OCCUR UNLESS NOTED OTHERWISE.
E. PAINT FIRE EXTINGUISHER CABINETS, FIRE VALVE CABINETS TO MATCH THE COLOR OF THE WALL IN
WHICH THEY OCCUR, UNLESS OTHERWISE NOTED.
F. PAINT EXPOSED SPEAKER ENCLOSURES / COVERS WITH A PAINT THAT WILL NOT DEGRADE
ACOUSTICAL PERFORMANCE. COLOR TO MATCH THE WALL OR CEILING IN WHICH THEY OCCUR,
UNLESS OTHERWISE NOTED.
G. BLANKED-OUT AREAS BEHIND MECHANICAL DIFFUSERS ARE TO BE PAINTED BLACK.
H. DOORS AND FRAMES SCHEDULED FOR PAINT WITHIN THE BACK-OF-HOUSE SPACES ADJACENT TO
UNPAINTED WALLS ARE TO BE PAINTED PT-01, UNLESS OTHERWISE NOTED.
I. DOORS AND FRAMES SCHEDULED FOR PAINT ARE TO BE PAINTED AS INDICATED ON FINISH PLANS
AND INTERIOR ELEVATIONS.
J. GYPSUM WALLBOARD CEILINGS ARE TO BE PAINTED PT-01 UNLESS OTHERWISE INDICATED.
K. LOCATE CONTROL JOINTS IN TILE FLOORS PER TILE COUNCIL OF NORTH AMERICA (TCNA)
RECOMMENDATIONS AND STANDARDS. OFFSET CONTROL JOINTS TO CLOSEST GROUT JOINT FROM
CONTROL JOINT IN SLAB. DO NOT CUT TILES.
L. TILE DIMENSIONS ARE TO CENTER OF GROUT JOINT, TYPICAL.
M. FLOOR MATERIAL TRANSITIONS AT DOOR OPENINGS ARE TO BE CENTERED BELOW DOOR IN THE
CLOSED POSITION.
N. ELECTRICAL SWITCH AND OUTLET COVER PLATES, SURFACE HARDWARE, ETC. SHALL BE INSTALLED AFTER PAINTING, APPLICATION OF WALL AND/OR FLOOR COVERINGS. ELECTRICAL SWITCH AND
OULETS TO MATCH ON WALL ON WHICH THEY OCCUR.
O. PROVIDE FINISHED SURFACES AT AREAS THAT ARE EXPOSED BEHIND ANY APPLIED MILLWORK, FILE
CABINETS, PANELS SLIDING DOORS. MATCH ADJACENT WALL SURFACE.
P. GYPSUM WALLBOARD PARTITIONS SCHEDULED TO RECEIVE PAINT FINISH: LEVEL (4) FINISH.
Q. GYPSUM WALLBOARD PARTITIONS SCHEDULED TO RECEIVE WALL COVERING: LEVEL (5) FINISH.
R. PROVIDE RESILIENT REDUCER STRIPS AT THE TRANSITIONS WHERE CARPET ABUTS HARD SURFACE
FLOORING, UNLESS OTHERWISE NOTED. MATERIAL, COLOR, AND PROFILE AS SELECTED BY
ARCHITECT.
S. REFER TO ELEVATIONS AND INTERIOR FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
SHEET NUMBER
442 W Kennedy Blvd Suite 312 Tampa Florida 33606 tvsdesign.com
SHEET TITLE
SEAL
987654321
B
A
D
C
TVS PROJECT NUMBER
F
E
H
G
J
K
B
A
D
C
F
E
H
G
J
K
987654321
TVS FLORIDA, INC., ARCHITECTURE
Scales as stated hereon are valid on the original drawing, the dimensions of which are 30x42 inches. These scales noted hereon are hereby changed by the ratio of the overall sheet dimensions of the print to the corresponding dimensions of the original drawing.
© TVS FLORIDA, INC., ARCHITECTURE
This drawing is the property of TVS FLORIDA, INC., ARCHITECTURE and is not to be reproduced or copied in whole or in part. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
M
L
N
M
L
N
RELEASED FOR CONSTRUCTION
ORIGINAL ISSUE DATE
P P
605 E. ROBINSON STREET, SUITE 750 ORLANDO, FL 32801
407.648.7288 www.rbarchitects.com AR0014284
9/
/2
3:
:2
P
M A ut od es k
D oc s:
//P
-2
O ra ng e
C ou nt y
C on ve nt io n
C en te r/
P -2
_A R
C H
_I nt er io r.
rv t
G-040
GENERAL MEETING ROOM FINISH SCHEDULE
9899 International Dr, Orlando, FL 32819
P-20257
09/09/24
09/09/2024
OCCC NORTH SOUTH BUILDING
MEETING ROOMS RENOVATION
INTERIOR FINISH SCHEDULE
FINISH MATERIAL DESIGNATION SPECIFICATION NO. SPECIFICATION NAME BASIS OF DESIGN MANUFACTURER STYLE NAME STYLE NUMBER FINISH FINISH SIZE INSTALLATION METHOD LOCATION COMMENTS (EDGE, GROUT, TRIM, ETC.)
ACOUSTICAL CEILING TILE
ACT-01 09 5123 ACOUSTICAL CEILING TILE ARMSTRONG CALLA WHITE 24" X 72" SQUARE TEGULAR PRELUDE GRID, 15/16
ACT-02 09 5123 ACOUSTICAL CEILING TILE ARMSTRONG CALLA WHITE 24" X 24" SQUARE TEGULAR PRELUDE GRID, 15/16
ACT-03 09 5123 ACOUSTICAL CEILING TILE ARMSTRONG CALLA WHITE 24" X 36" SQUARE TEGULAR PRELUDE GRID, 15/16
ACT-04 09 5123 ACOUSTICAL CEILING TILE ARMSTRONG CALLA WHITE 24" X 60" SQUARE TEGULAR PRELUDE GRID, 15/16
ACT-05 09 5123 ACOUSTICAL CEILING TILE ARMSTRONG CALLA WHITE 24" X 48" SQUARE TEGULAR PRELUDE GRID, 15/16
ACOUSTICAL WRAPPED PANELS
AP-01 09 7713 STRETCHED-FABRIC WALL SYSTEMS CARNEGIE XOREL STRIE 6423 819 ACCUTRACK ACCUSNAP SYSTEM
AP-02 09 7713 STRETCHED-FABRIC WALL SYSTEMS CARNEGIE XOREL SLEET EMBROIDER 6299 817 ACCUTRACK ACCUSNAP SYSTEM
AP-03 09 7713 STRETCHED-FABRIC WALL SYSTEMS CARNEGIE XOREL STRIE 6423 820 ACCUTRACK ACCUSNAP SYSTEM
CARPET
CPT-01 09 6813 TILE CARPETING MILLIKEN GRAND PLAZA G1-12-05 01415529 1M x 1M, 40 OZ, .42" THICK
TUFTED CARPET TILE
CPT-02 09 6813 TILE CARPETING MILLIKEN GRAND PLAZA G1-12-05 01415545 1M x 1M, 40 OZ, .42" THICK
TUFTED CARPET TILE
CORNER GUARDS
CG-01 10 2600 WALL AND DOOR PROTECTION FRY REGLET MWPOSC25100 TBD 1" SIGNATURE ROOMS
CURTAINS AND DRAPES
DP-01 12 2200 CURTAINS AND DRAPES BART HALPERN PEBBLE BEACH 71600-01 54" SIGNATURE ROOMS BLACKOUT BACKING, 50% ACRYLIC, 48% POLYESTER, 2% LINEN, 200%
FULLNESS
DP-02 12 2200 CURTAINS AND DRAPES POLLACK MALTA 9252/01 SNOW 118", 12 OZ. SIGNATURE ROOMS LIGHT FILTERING, 100% POLYESTER, 200% FULLNESS
INTERIOR GLASS
GL-01 08 8113 DECORATIVE GLASS MCGRORY GLASS INC TVSGA-737 1/4" DEPTH TEMPERED
METAL PANEL CEILING
MP-01 09 5133 ACOUSTICAL METAL PAN CEILINGS ARMSTRONG METALWORK TORSION SPRING CEILING #7213M16FX DYE SUBLIMATION WOOD LOOK - MATCH
ARCHITECT'S SAMPLE
CUSTOM SIZE CUSTOM METALWORKS 1 1/4" EXTRUDED ALUMINUM MILL FINISH GRID SYSTEM SIGNATURE ROOMS CUSTOM CURVED CEILING, .063 ALUMINUM, M16 PERFORATION, RD3223
OPERABLE PARTITION (TEXTILE)
OP-01 10 2226 OPERABLE PARTITION CARNEGIE XOREL STRIE 6423 819
OP-02 10 2226 OPERABLE PARTITION CARNEGIE XOREL STRIE 6423 820
PAINT
PT-01 09 9123 INTERIOR PAINTING BENJAMIN MOORE SUPER WHITE OC-152
PT-02 09 9123 INTERIOR PAINTING SHERWIN WILLIAMS SKYLINE STEEL SW1015
PT-03 09 9123 INTERIOR PAINTING PPG BREAD BASKET 1087-6
PT-04 09 9123 INTERIOR PAINTING SHERWIN WILLIAMS INDIGO BATIK SW7602
PT-05 09 9123 INTERIOR PAINTING PAINT TO MATCH EXISTING
ROLLER SHADE
RS-01 12 2513 ROLLER SHADE MECHO SHADE CHELSEA BLACKOUT 0250 SERIES 0251 CHALK SIGNATURE ROOMS
RS-02 12 2513 ROLLER SHADE MECHO SHADE ECOSHEER (3% OPEN) 6750 SERIES 6751 PORCELAIN SIGNATURE ROOMS
WALL COVERING
WC-01 09 72 00 WALL COVERINGS LBI BOYD DESIGN RESOURCE BREAKWATER SSM-WC-IL GLOW MEETING ROOM N230
WOOD BASE
WB-01 06 4023 INTERIOR ARCHITECTURAL WOODWORK SOLID WOOD POPLAR PAINTED TO MATCH ADJACENT WALL 3/4" D X 8" H APPLIED WOOD BASE
WB-02 06 4023 INTERIOR ARCHITECTURAL WOODWORK SOLID WOOD POPLAR SHERWIN WILLIAMS SKYLINE STEEL SW 1015 3/4" D X 8" H APPLIED WOOD BASE
WB-03 06 4023 INTERIOR ARCHITECTURAL WOODWORK SOLID WOOD POPLAR SHERWIN WILLIAMS INDIGO BALTIK SW 7602 3/4" D X 8" H APPLIED WOOD BASE MEETING ROOM N330
WB-04 06 4023 INTERIOR ARCHITECTURAL WOODWORK SOLID WOOD SOLID WOOD TO MATCH
ADJACENT VENEER
STAINED TO MATCH VENEER 3/4" D X 8" H FLUSH WOOD BASE AT WOOD VENEER WALL LOCATIONS
WOOD VENEER
WD-01 06 4000 ARCHITECTURAL WOODWORK ARCHITECTURAL VENEERS INTL RIFT WHITE OAK FLITCH NO. 5730-3595 SIGNATURE ROOMS
NO. REVISIONS / SUBMISSIONS DATE
ISSUED FOR PERMIT 09/09/2024
GRAPHIC LEGEND
SPECIFIED GLASS AS PART OF
SYSTEM
DUAL LOCK CLIP
GRAPH WALL SYSTEM FRAME
ATTACHED WITH DRYWALL
SCREWS OR EXPANSION
FASTENERS. BASIS OF DESIGN:
FRY REGLET
FIRE-RETARDANT TREATED BLOCKING
MID WALL FASTENING SYSTEM
MECHANICALLY FASTENED TO WALL
EXISTING
5/8"GYPSUM BOARD
1" ACOUSTIC WRAPPED PANEL; REFERENCE
INTERIOR FINISH SCHEDULE ON SHEET G-040
FABRIC IN CONTACT WITH EDGE OF TRACK ONLY
ACCUSNAP TRACK; REFERENCE INTERIOR
FINISH SCHEDULE ON SHEET G-040
EXISTING CMU WALL
EXISTING STRUCTURE
TO REMAIN
EXISTING PARTITION TO REMAIN
EXISTING ELEMENT TO BE
DEMOLISHED
NEW PARTITION
EXISTING BUILDING AREAS TO
REMAIN - (AREA NOT IN SCOPE)
TOP OF FINISH FLOOR
3/4" THICK WOOD BASE,
REFER TO ELEVATIONS
/4
SCRIBE TO FLOOR
EXISTING SLAB
ACOUSTICAL SEALANT
COUNCOURSE LEVEL
120' - 0"
5/8" GYPSUM WALLBOARD
COLD-FORMED METAL FRAMING
GRAPH WALL SYSTEM
INTERMEDIATE RETAINER
BASIS OF DESIGN: FRY REGLET
GRAPH WALL SYSTEM
SINGLE FIN BASE TERMINATION
BASIS OF DESIGN: FRY REGLET
/8
CONCOURSE
SIDE
MEETING ROOM
SIDE
BACK-PAINTED GLASS, GL-01 BACK-PAINTED GLASS, GL-01
GRAPH WALL SYSTEM
INTERMEDIATE RETAINER
BASIS OF DESIGN: FRY REGLET
EXISTING PARTITION
SCHEDULED WALL BASE,
PAINTED TO MATCH GL-01
SCHEDULED WALL BASE,
PAINTED TO MATCH GL-01
GRAPH WALL SYSTEM
INTERMEDIATE RETAINER
BASIS OF DESIGN: FRY REGLET
BACK-PAINTED GLASS, GL-01
COLD-FORMED METAL FRAMING
5/8" GYPSUM WALLBOARD
GRAPH WALL SYSTEM SINGLE FIN
CEILING TERMINATION
BASIS OF DESIGN: FRY REGLET
EXISTING PARTITION
GRAPH WALL SYSTEM
INTERMEDIATE RETAINER
BASIS OF DESIGN: FRY REGLET
BACK-PAINTED GLASS, GL-01
GRAPH WALL SYSTEM
SINGLE FIN BASE TERMINATION
BASIS OF DESIGN: FRY REGLET
/8
GRAPH WALL SYSTEM SINGLE FIN
CEILING TERMINATION
BASIS OF DESIGN: FRY REGLET
5/8" GYPSUM WALLBOARD
3 5/8" COLD-FORMED
METAL FRAMING
14' - 6"
FIRE-RETARDANT TREATED
BLOCKING, TYP.
FIRE-RETARDANT TREATED
BLOCKING, TYP.
7/8"
5/8" GYPSUM WALLBOARD
7/8" HAT CHANNEL ASSEMBLY
NX
1' - 0"
EXISTING PARTITION
EXISTING SOFFIT OVERHEAD
SCHEDULED BACK-PAINTED GLASS, GL-01
GFRG COLUMN COVER BEYOND,
TO ALIGN WITH EXISTING SOFFIT.
GRAPH WALL SYSTEM SINGLE FIN
CEILING TERMINATION
BASIS OF DESIGN: FRY REGLET
CONCOURSE SIDE
3 5/8" COLD FORMED METAL FRAMING
5/8" GYPSUM WALLBOARD,
PAINTED PT-01
6" COLD FORMED METAL FRAMING
23' - 3"
V.I.F.
SHEET NUMBER
442 W Kennedy Blvd Suite 312 Tampa Florida 33606 tvsdesign.com
SHEET TITLE
SEAL
987654321
B
A
D
C
TVS PROJECT NUMBER
F
E
H
G
J
K
B
A
D
C
F
E
H
G
J
K
987654321
TVS FLORIDA, INC., ARCHITECTURE
Scales as stated hereon are valid on the original drawing, the dimensions of which are 30x42 inches. These scales noted hereon are hereby changed by the ratio of the overall sheet dimensions of the print to the corresponding dimensions of the original drawing.
© TVS FLORIDA, INC., ARCHITECTURE
This drawing is the property of TVS FLORIDA, INC., ARCHITECTURE and is not to be reproduced or copied in whole or in part. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
M
L
N
M
L
N
RELEASED FOR CONSTRUCTION
ORIGINAL ISSUE DATE
P P
605 E. ROBINSON STREET, SUITE 750 ORLANDO, FL 32801
407.648.7288 www.rbarchitects.com AR0014284
9/
/2
3:
:3
P
M A ut od es k
D oc s:
//P
-2
O ra ng e
C ou nt y
C on ve nt io n
C en te r/
P -2
_A R
C H
_I nt er io r.
rv t
G-120
TYPICAL WALL DETAILS
9899 International Dr, Orlando, FL 32819
P-20257
09/09/24
09/09/2024
OCCC NORTH SOUTH BUILDING
MEETING ROOMS RENOVATION
6" = 1'-0"
E,9 PLAN DETAIL - GLASS PANEL TO GYPSUM
3" = 1'-0"
J,9 PLAN DETAIL - WALL PANEL FASTENING SYSTEM
3" = 1'-0"
A,9 SECTION DETAIL - APPLIED WOOD BASE
-1 1/2" = 1'-0" -
A,5 SECTION DETAIL - DECORATIVE GLASS - CONCOURSE LEVEL
1 1/2" = 1'-0" -
J,5 SECTION DETAIL - DECORATIVE GLASS HEADER - MEZZANINE LEVEL
NO. REVISIONS / SUBMISSIONS DATE
ISSUED FOR PERMIT 09/09/2024
GRAPHIC LEGEND
EXISTING WALL TO REMAIN.
SEE FINISH SCHEDULE FOR
ADDITIONAL INFORMATION
2" 2"
REFER TO RCPS
REFER TO RCPS
EXISTING METAL FRAMING TO
REMAIN. FIELD VERIFY
CONDITIONS
SUSPENDED ACOUSTICAL
CEILING SYSTEM
EXISTING GWB AT FACIA &
RETURN ABOVE TO REMAIN
CORNER BEAD
RECESSED LINEAR LIGHT
FIXTURE, SEE RCP
GWB ON EXISTING METAL
FRAMING
REFER TO RCP
VARIES (EXISTING)
SEE INTERIOR ELEVATIONS
FOR FINISHES
HVAC DIFFUSER, SEE RCP
EQ EQ
DEVICES IN SOFFIT MAY VARY FROM WHAT IS
SHOWN ON THIS DETAIL DEPENDING ON
LOCATION. REFER TO RCP, TYPICAL
REFER TO RCPS
VARIES
EXISTING STRUCTURE
TO REMAIN
EXISTING PARTITION TO REMAIN
EXISTING ELEMENT TO BE
DEMOLISHED
NEW PARTITION
EXISTING BUILDING AREAS TO
REMAIN - (AREA NOT IN SCOPE)
6' - 0"
2X6 CEILING PANEL.
SIMILAR LAYOUT FOR
OTHER SIZES. REFER TO
CEILING PLANS
DEVICE LOCATION
CENTERPOINT, TYP. SIZE AND
SHAPE OF DEVICES VARY
DEPENDING ON PRODUCT.
REFER TO RCP FOR DEVICE
TYPE AND LOCATION.
ALIGN DEVICES HORIZONTALLY AND
VERTICALLY ALONG GRID AS INDICATED
RECESSED LINEAR LIGHT
FIXTURE WHERE
APPLICABLE. REFER TO
REFLECTED CEILING
PLAN FOR LOCATIONS.
CUT CEILING TILE AS
REQUIRED
V
IF
/4
/4
THIS DRAWING SHOWS AN OVERLAY OF THE
EXISTING DEVICE PLACEMENT GRID ON THE NEW
2'-0"x6'-0" SUSPENDED CEILING TILES. THE INTENT
IS TO REINSTALL SALVAGED DEVICES AS CLOSE
AS POSSIBLE TO THEIR ORIGINAL LOCATIONS
WHILE ALIGNING DEVICES HORIZONTALLY AND
VERTICALLY ALONG GRID. CENTERPOINT OF
DEVICES TO ALIGN WITH CENTERPOINT OF
CLOSEST REGULATING GRID INTERSECTION.
6" 1' - 0" 1' - 0" 1' - 0" 1' - 0" 1' - 0" 6"
LOCATION OF LIGHT
FIXTURE TO BE INSET FROM
TYPICAL SUSPENDED GRID
DIMENSION. VERIFY
INSTALLATION DETAIL &
WIDTH WITH FIXTURE MFR.
LIGHT FIXTURE
PRIMARY ACT GRID HANGER
FULL CEILING TILE
CUT CEILING TILE
2"
ACOUSTICAL WALL TREATMENT WHERE
APPLICABLE. REFER TO INTERIOR
ELEVATIONS AND FINISH SCHEDULE.
GWB WALL EXPANSION JOINT
ASSEMBLY. BOD: INPRO 300
SERIES
EXISTING GWB FINISH AND METAL
FRAMING TO REMAIN. MODIFY AS
REQUIRED TO INSTALL EXPANSION JOINT
ASSEMBLY PRIOR TO APPLYING NEW
FINISHES
6 1/4"
2" EXPANSION JOINT ASSEMBLY,
FOAM SEAL WITH PAINT FINISH.
BOD: INPRO 1200 SERIES
GFRG COLUMN COVER
EXISTING COLUMN
TO REMAIN
METAL FRAMING AS
REQUIRED BY GFRG
MANUFACTURER
2"
EXISTING METAL FRAMING
TO REMAIN
5/8" GYP BD ON EXISTING FRAMING
GWB CEILING EXPANSION JOINT
ASSEMBLY. BOD: INPRO 112 SERIES
2"
PROVIDE NEW EXPANSION JOINT
COVER PLATE, TYPICAL. FIELD
VERIFY. BOD: BALCO NBAF-2
FLOORING AS SCHEDULED
EXISTING EXPANSION
JOINT ASSEMBLY TO
REMAIN. PROTECT
FIRE BARRIER
2"
4"
REMOVABLE, STEEL COVER PLATE
W/RECESSED CARPET INSERT TO
MATCH…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .