P403 ENLARGED CREW PIPING PLAN NORTH_Amd01_2020-09-14.pdf

PDF 428 KB Posted

Attached to
Alert Facility and Alert Apron
Solicitation number
N69450-20-R-0129
Issued by

About this file

This solicitation is for the design and construction of an Alert Facility and Alert Apron at NAS JRB New Orleans. The construction project includes building an Aerospace Control Alert Facilities and Alert Apron to accommodate the mission, with two aircraft shelters that have drive-through capability, installed heating, fire suppression, metal walls, and standing seam metal roofs. An aircrew alert quarters/mission support structure will be built with Alternate Command Post capabilities, a secure area, and entry control facility. Standby power, pile foundations, and site preparation including surcharging will be provided. The Alert Apron construction will provide all utilities, communication support, site improvements, exterior lighting, lightning protection, and security upgrades. An parking apron for two alert ready aircraft will be erected, with security fencing, access gates, airfield lighting, security lighting with controls and communications and electrical conduit. Pile foundations will be provided, as well as site preparation including soil dewatering as required. This will result in a firm-fixed price construction contract awarded using the design-bid-build method, with a completion schedule of 1300 calendar days from award date. The project magnitude is estimated between $25,000,000 to $100,000,000. The solicitation is unrestricted and open to all responsible sources.

View the file

Other files

File Type Posted
N6945020R0129_Amendment_0007.pdf PDF
N69450-20-R-0129_AMENDMENT_0006.pdf PDF
C201 SITE PLAN_Amd06_2020-10-21.pdf PDF
C511 STORM DRAINAGE DETAILS_Amd06_2020-10-21.pdf PDF
N6945020R0129_0005.pdf PDF
Amd_0004_CLINS.pdf PDF
N6945020R0129_Amendment_0004.pdf PDF
E505 - ELECTRICAL DETAILS_Amd0003_2020-10-06.pdf PDF
ESD109 - ELECTRICAL SITE DEMOLITION_Amd0003_2020-10-06.pdf PDF
ESD106 - ELECTRICAL SITE DEMOLITION_Amd0003_2020-10-06.pdf PDF
PROJECT TOC Amendment 0003.pdf PDF
ESD105 - ELECTRICAL SITE DEMOLITION_Amd0003_2020-10-06.pdf PDF
32 11 23 Amendment 0003.pdf PDF
G003 - OVERALL PROJECT MAP_Amd0003_2020-10-06.pdf PDF
ESD107 - ELECTRICAL SITE DEMOLITION_Amd0003_2020-10-06.pdf PDF
32 11 20 Amendment 0003.pdf PDF
32 12 16 Amendment 0003.pdf PDF
32 01 13.62 Amendment 0003.pdf PDF
ESD108 - ELECTRICAL SITE DEMOLITION_Amd0003_2020-10-06.pdf PDF
E506 - ELECTRICAL DETAILS_Amd0003_2020-10-06.pdf PDF
N6945020R0129_0003.pdf PDF
A602 - DOOR_WINDOW_LOUVER DETAILS Amd 0002.pdf PDF
01 30 01_00 22 Amendment 0002.pdf PDF
A351 - SHELTER_1 BUILDING SECTIONS Amd 0002.pdf PDF
P402 - ENLARGED CREW SANITARY PLAN SOUTH Amd 0002.pdf PDF
A353 - SHELTER WALL SECTIONS Amd 0002.pdf PDF
10 26 00 Amendment 0002.pdf PDF
C200 - OVERALL SITE PLAN Amd 0002.pdf PDF
C201 - SITE PLAN Amd 0002.pdf PDF
N6945020R0129_Amendment_0002.pdf PDF
A701 - FINISH LEGEND AND SCHEDULE Amd 0002.pdf PDF
C101 - EXISTING CONDITIONS AND SURCHARGE SITE PLAN Amd 0002.pdf PDF
13 34 19 Amendment 0002.pdf PDF
CA200 - APRON GEOMETY AND UTILITY PLAN Amd 0002.pdf PDF
10 21 23.16 Amendment 0002.pdf PDF
A201 - ACQ_ECP EXTERIOR ELVATIONS Amd 0002.pdf PDF
C401 - GRADING AND DRAINAGE PLAN Amd 0002.pdf PDF
PROJECT TOC Amendment 0002.pdf PDF
A601 - DOOR - WINDOW ELEVATIONS_DOOR SCHEDULE Amd 0002.pdf PDF
01 35 13 Amendment 0002.pdf PDF
A352 - SHELTER_ BUILDING SECTIONS Amd 0002.pdf PDF
08 34 02 Amendment 0002.pdf PDF
10 51 13 Amendment 0002.pdf PDF
S154 - SHELTER_2 SLAB PLAN Amd 0002.pdf PDF
E503 ELECTRICAL DETAILS_Amd01_2020-09-14.pdf PDF
P401 ENLARGED CREW SANITARY PLAN NORTH_Amd01_2020-09-14.pdf PDF
NOLA_Alert_R0129_SiteVisit_Roster.pdf PDF
ES107 ELECTRICAL SITE PLAN - NEW WORK_Amd01_2020-09-14.pdf PDF
P104 OVERALL SHELTER 2 PLUMBING PLAN_Amd01_2020-09-14.pdf PDF
S001 GENERAL NOTES_DESIGN CRITERIA_Amd01_2020-09-14.pdf PDF
Show 40 more

Latest 50 of 72 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF.REF.

AB

AC

AA

AA.5

A3

A1 A4A2 A5

P403

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D S

O U

TH

E

A S

T

N O

R

TH

C O

M

C O

N S

TR

U

C T

A

LE

R T

FA

C

IL

IT

IE

S

SHEET KEY NOTES

GRAPHIC SCALE

KEYPLAN

B-3 SUBMITTAL 02/28/2020

SHEET KEY NOTES (CONT'D)

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

BATH

AutoCAD SHX Text 122A

AutoCAD SHX Text

BATH

AutoCAD SHX Text 120A

AutoCAD SHX Text S-1

AutoCAD SHX Text S-1

AutoCAD SHX Text S-2

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text L-1

AutoCAD SHX Text

WC-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

SH-1

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text

COMMUNICATIONS

AutoCAD SHX Text

AutoCAD SHX Text

BATH

AutoCAD SHX Text 124A

AutoCAD SHX Text

BATH

AutoCAD SHX Text 126A

AutoCAD SHX Text

SHIFT ADVISOR

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

AutoCAD SHX Text

BATH

AutoCAD SHX Text 123A

AutoCAD SHX Text

BATH

AutoCAD SHX Text 125A

AutoCAD SHX Text

MAINTENANCE READY ROOM

AutoCAD SHX Text

LOUNGE\

AutoCAD SHX Text

AutoCAD SHX Text

BENCH STOCK

AutoCAD SHX Text

SUPPLY PARK

AutoCAD SHX Text

AutoCAD SHX Text

MANAGER

AutoCAD SHX Text

CHEIF ENLISTED

AutoCAD SHX Text

AutoCAD SHX Text

STATION TO/LIBRARY

AutoCAD SHX Text

AIRCRAFT/FORM WORK/

AutoCAD SHX Text

AutoCAD SHX Text

BATH

AutoCAD SHX Text 127A

AutoCAD SHX Text

BRIEF/DEBRIEF

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

AutoCAD SHX Text

DINING

AutoCAD SHX Text

KITCHEN/

AutoCAD SHX Text

AutoCAD SHX Text

BREAK ROOM

AutoCAD SHX Text

TRAINING/

AutoCAD SHX Text

AutoCAD SHX Text

LOCKERS

AutoCAD SHX Text

OP & MAINT

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

PANTRY

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAINTENANCE

AutoCAD SHX Text

BEDROOM

AutoCAD SHX Text

AutoCAD SHX Text

CONTROL

AutoCAD SHX Text

NOISE

AutoCAD SHX Text

AutoCAD SHX Text

BFP-1

AutoCAD SHX Text

TMV-1

AutoCAD SHX Text

HWRP-1

AutoCAD SHX Text

BFP-2

AutoCAD SHX Text

GWH-1

AutoCAD SHX Text

GWH-2

AutoCAD SHX Text B-1

AutoCAD SHX Text

WH-1

AutoCAD SHX Text

WH-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

2" FD-1FD-1

AutoCAD SHX Text

3" FD-1FD-1

AutoCAD SHX Text

3" FD-1FD-1

AutoCAD SHX Text

3" FD-1FD-1

AutoCAD SHX Text

TP-1

AutoCAD SHX Text

AutoCAD SHX Text NEW WORK PLAN NOTES: : 1. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO SHOWER SH-1. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO SHOWER SH-1. SH-1. . 2. 1/2" COLD WATER DOWN TO WATER CLOSET WC-1. 1/2" COLD WATER DOWN TO WATER CLOSET WC-1. WC-1. . 3. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO LAVATORY L-1. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO LAVATORY L-1. L-1. . 4. 1-1/2" COLD WATER AND 3/4" HOT WATER RETURN DOWN TO GWH-1 AND GWH-2. 1-1/2" COLD WATER AND 3/4" HOT WATER RETURN DOWN TO GWH-1 AND GWH-2. GWH-1 AND GWH-2. AND GWH-2. GWH-2. 5. 1-1/2" HOT WATER DOWN TO GWH-1 AND GWH-2. 1-1/2" HOT WATER DOWN TO GWH-1 AND GWH-2. GWH-1 AND GWH-2. AND GWH-2. GWH-2. 6. 1" NATURAL GAS PIPE TO BOILER B-1. 1" NATURAL GAS PIPE TO BOILER B-1. B-1. . 7. 1-1/4" COLD AND 1" HOT WATER DOWN TO SINKS, DISHWASHER, ICE MACHINE AND 1-1/4" COLD AND 1" HOT WATER DOWN TO SINKS, DISHWASHER, ICE MACHINE AND HOSE BIBB. 8. GAS METER AND REGULATOR LOCATED ABOVE GRADE AT BUILDING EXTERIOR. GAS METER AND REGULATOR LOCATED ABOVE GRADE AT BUILDING EXTERIOR. PROVIDE METER AND REGULATOR SIZED FOR 710 CFH. SEE DETAIL 3/P502. 9. PROVIDE 6" REINFORCED CONCRETE PAD FOR GAS FIRED WATER HEATERS AND PROVIDE 6" REINFORCED CONCRETE PAD FOR GAS FIRED WATER HEATERS AND BOILER. 10. 3/4" NATURAL GAS PIPE DOWN TO RANGE. INSTALL REMOTE OPERATED SHUTOFF 3/4" NATURAL GAS PIPE DOWN TO RANGE. INSTALL REMOTE OPERATED SHUTOFF VALVE PROVIDED AS HOOD ACCESSORY. TIE IN TO HOOD FIRE SUPPRESSION SYSTEM. 11. 3/4" NATURAL GAS PIPE DOWN AND TERMINATE WITH VALVE IN VALVE BOX AT PATIO. 3/4" NATURAL GAS PIPE DOWN AND TERMINATE WITH VALVE IN VALVE BOX AT PATIO. 12. 1/2" CW TRAP PRIMER FROM WC-1. 1/2" CW TRAP PRIMER FROM WC-1. 13. SEE CIVIL FOR CONTINUATION. SEE CIVIL FOR CONTINUATION. 14. AUTOMATED GAS SHUTOFF VALVE (INTEGRATION WITH KLAXXON SYSTEM BY GOV'T). AUTOMATED GAS SHUTOFF VALVE (INTEGRATION WITH KLAXXON SYSTEM BY GOV'T). 15. SEE DETAIL 6/P502 FOR BACKFLOW PREVENTER AND WATER METER ASSEMBLY.SEE DETAIL 6/P502 FOR BACKFLOW PREVENTER AND WATER METER ASSEMBLY.

AutoCAD SHX Text NEW WORK PLAN NOTES: : 1. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO SHOWER SH-1. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO SHOWER SH-1. SH-1. . 2. 1/2" COLD WATER DOWN TO WATER CLOSET WC-1. 1/2" COLD WATER DOWN TO WATER CLOSET WC-1. WC-1. . 3. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO LAVATORY L-1. 1/2" COLD WATER AND 1/2" HOT WATER DOWN TO LAVATORY L-1. L-1. . 4. 1-1/2" COLD WATER AND 3/4" HOT WATER RETURN DOWN TO GWH-1 AND GWH-2. 1-1/2" COLD WATER AND 3/4" HOT WATER RETURN DOWN TO GWH-1 AND GWH-2. GWH-1 AND GWH-2. AND GWH-2. GWH-2. 5. 1-1/2" HOT WATER DOWN TO GWH-1 AND GWH-2. 1-1/2" HOT WATER DOWN TO GWH-1 AND GWH-2. GWH-1 AND GWH-2. AND GWH-2. GWH-2. 6. 1" NATURAL GAS PIPE TO BOILER B-1. 1" NATURAL GAS PIPE TO BOILER B-1. B-1. . 7. 1-1/4" COLD AND 1" HOT WATER DOWN TO SINKS, DISHWASHER, ICE MACHINE AND 1-1/4" COLD AND 1" HOT WATER DOWN TO SINKS, DISHWASHER, ICE MACHINE AND HOSE BIBB. 8. GAS METER AND REGULATOR LOCATED ABOVE GRADE AT BUILDING EXTERIOR. GAS METER AND REGULATOR LOCATED ABOVE GRADE AT BUILDING EXTERIOR. PROVIDE METER AND REGULATOR SIZED FOR 710 CFH. SEE DETAIL 3/P502. 9. PROVIDE 6" REINFORCED CONCRETE PAD FOR GAS FIRED WATER HEATERS AND PROVIDE 6" REINFORCED CONCRETE PAD FOR GAS FIRED WATER HEATERS AND BOILER. 10. 3/4" NATURAL GAS PIPE DOWN TO RANGE. INSTALL REMOTE OPERATED SHUTOFF 3/4" NATURAL GAS PIPE DOWN TO RANGE. INSTALL REMOTE OPERATED SHUTOFF VALVE PROVIDED AS HOOD ACCESSORY. TIE IN TO HOOD FIRE SUPPRESSION SYSTEM. 11. 3/4" NATURAL GAS PIPE DOWN AND TERMINATE WITH VALVE IN VALVE BOX AT PATIO. 3/4" NATURAL GAS PIPE DOWN AND TERMINATE WITH VALVE IN VALVE BOX AT PATIO. 12. 1/2" CW TRAP PRIMER FROM WC-1. 1/2" CW TRAP PRIMER FROM WC-1. 13. SEE CIVIL FOR CONTINUATION. SEE CIVIL FOR CONTINUATION. 14. AUTOMATED GAS SHUTOFF VALVE (INTEGRATION WITH KLAXXON SYSTEM BY GOV'T). AUTOMATED GAS SHUTOFF VALVE (INTEGRATION WITH KLAXXON SYSTEM BY GOV'T). 15. SEE DETAIL 6/P502 FOR BACKFLOW PREVENTER AND WATER METER ASSEMBLY.SEE DETAIL 6/P502 FOR BACKFLOW PREVENTER AND WATER METER ASSEMBLY.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AMENDENT 0001

AutoCAD SHX Text 09/14/2020

AutoCAD SHX Text SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 7 AUGUST 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

FOR COMMANDER NAVFAC / B.L.T.L.

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

ENLARGED CREW PIPING PLAN NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 15135331

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NAVAL AIR STATION JACKSONVILLE

AutoCAD SHX Text

NAS JRB NEW ORLEANS

AutoCAD SHX Text

NEW ORLEANS, LA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DESIGN MANAGER

AutoCAD SHX Text

M CONTESTABILE

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

JOANNE DIZ

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

ANTHONY DISANTO

AutoCAD SHX Text 1621243

AutoCAD SHX Text

N69450-XX-C-XXXX

AutoCAD SHX Text 1'

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 15'

AutoCAD SHX Text 10'

AutoCAD SHX Text 5'

AutoCAD SHX Text 1'

AutoCAD SHX Text 0'

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text Scale:

AutoCAD SHX Text A

AutoCAD SHX Text

CREW PIPING PLAN NORTH

AutoCAD SHX Text 1/4" = 1'-0"

Sheets and Views
P403 ENLARGED CREW PIPING PLAN NORTH
crew piping n
crew pipe n notes

File details come from the government source that posted it. Updated .