10 51 13 Amendment 0002.pdf
PDF 27 KB Posted
- Attached to
- Alert Facility and Alert Apron Federal contract opportunity
- Solicitation number
- N69450-20-R-0129
About this file
This document contains a federal solicitation for the construction of an Alert Facility and Alert Apron at NAS JRB New Orleans. The solicitation seeks the construction of an Aerospace Control Alert Facilities and Alert Apron utilizing conventional design and build methods. The facilities must accommodate the mission and be designed in accordance with UFC requirements. The Alert Facility requires two aircraft shelters with drive-through capability, installed heating, fire suppression, metal walls and standing seam metal roof. An aircrew alert quarters and mission support structure with Alternate Command Post capabilities, a secure area and entry control facility are also required. The solicitation requires the provision of standby power, pile foundations and site preparation including surcharging for the Alert Facility. The Alert Apron requires all utilities, communication support, site improvements, exterior and security lighting, lightning protection and security upgrades. A parking apron for two alert ready aircraft and security fencing, access gates with airfield lighting, security lighting controls and communications and electrical conduit must be provided. Pile foundations and site preparation including soil dewatering as required are also included. This will result in an award of a firm-fixed price design-bid-build construction contract for a total project completion schedule of 1300 calendar days from award. The project magnitude is between $25,000,000 to $100,000,000.
View the file
Other files for this federal contract opportunity
Show all 50
Alert Facility and Alert Apron has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NORTHCOM CONSTRUCT ALERT APRON/FACILITIES WON: 1323108/1621243
NAS JRB NEW ORLEANS, LOUISIANA B-3 DESIGN SUBMITTAL
SECTION 10 51 13
METAL LOCKERS
05/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A568/A568M (2017a) Standard Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for
ASTM B456 (2017) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
FS AA-L-00486 (Rev J) Lockers, Clothing, Steel
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Types; G
Numbering system
SD-03 Product Data; G, NAVFAC Interior Designer
Material
Locking Devices
Handles
Finish
Locker components
SD-04 Samples
SECTION 10 51 13 Page 1 michelle.contestabil Typewritten Text
REVISION 1: AMENDMENT 0002
Color chips; G, NAVFAC Interior Designer
1.3 DELIVERY, HANDLING, AND STORAGE
Deliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturer's name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.
1.4 FIELD MEASUREMENTS
To ensure proper fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location
1.5 QUALITY ASSURANCE
1.5.1 Color Chips
Provide a minimum of three color chips, not less than 2 inches square, of each color indicated.
Government may request performance-characteristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486. Lockers not conforming will be rejected.
PART 2 PRODUCTS
2.1 TYPES
Locker must have the following type and size in the location and quantities indicated. Locker finish colors will be selected from manufacturer's standard colors. Submit options to NAVFAC Interior Designer
2.1.1 Single-tier Lockers
Single-tier lockers must be as follows:
Type STL-1: Single-tier locker 12 inches wide, 15 inches deep, and 72 inches high, attached to 6-inch high base
Type STL-2: Single-tier locker 24 inches wide, 18 inches deep, and 72 inches high, attached to 6-inch high base
2.2 MATERIAL
2.2.1 Steel Sheet
ASTM A568/A568M, commercial quality, minimized spangle material. Prepare material surfaces for baked enamel finishing in accordance with FS AA-L-00486. Fabricate locker bodies from not less than 0.0239-inch thick steel sheet.
2.2.2 Chromium Coating
Nickel and chromium electrodeposited on the specified base metal. Conform to ASTM B456, SC-3, as applicable to the base metal.
SECTION 10 51 13 Page 2
2.2.3 Finish
Primer, topcoat.
2.2.3.1 Color
As selected from manufacturer's standard finishes.
2.3 [Enter Appropriate Subpart Title Here]COMPONENTS
2.3.1 Built-In Locks
FS AA-L-00486. Provide a padlock eye in the door latching mechanism.
Built-in locks are not required.
2.3.2 Coat Hooks
FS AA-L-00486, chromium plated.
2.3.3 Hanger Rods
FS AA-L-00486.
2.3.4 Door Handles
FS AA-L-00486. Provide steel handles with a chromium coating.
2.3.5 Doors
FS AA-L-00486, not less than 0.0598 inch thick steel sheet.
2.3.5.1 Hinges
In addition to the requirements of FS AA-L-00486, provide 5-knuckle hinges, minimum 2 inches high. Fabricate knuckle hinges from not less than 0.0787 inch thick steel sheet. A full height piano hinge may be provided if standard with the manufacturer. Weld or bolt hinges to the door frame.
Weld, bolt, or rivet hinges to the door.
2.3.5.2 Latching Mechanisms
FS AA-L-00486.
2.3.6 Latch Strikes
FS AA-L-00486. Fabricate from not less than 0.0787 inch thick steel sheet, except latch strike may be continuous from top to bottom and fabricated as part of the door framing.
2.3.7 Silencers
FS AA-L-00486.
2.3.8 Back and Side Panels, Tops, and Bottoms
FS AA-L-00486, not less than 0.0474 inch thick steel sheet.
SECTION 10 51 13 Page 3
2.3.9 Sloping Locker Tops
Provide sloping locker tops in addition to the locker-section flat tops.
Sloping tops must be continuous in length. Provide fillers or closures at the exposed end of sloping tops. Fabricate sloping tops from not less than 0.0478-inch thick steel sheet.
2.3.10 Shelves
FS AA-L-00486. Fabricate from not less than 0.0598 inch thick steel sheet.
2.3.11 Base Panels
FS AA-L-00486.
2.3.12 Number Plates
FS AA-L-00486. Aluminum. Provide consecutive numbers from 1 to 20.
2.3.13 Label Holders
FS AA-L-00486.
2.3.14 Fastening Devices
Provide bolts, nuts, and rivets as specified in FS AA-L-00486.
PART 3 EXECUTION
3.1 ASSEMBLY AND INSTALLATION
Assemble lockers according to the locker manufacturer's instructions.
Align lockers horizontally and vertically. Secure lockers to wall and base with screws as indicated. Bolt adjacent lockers together. Adjust doors to operate freely without sticking or binding and to ensure they close tightly.
3.2 FIELD QUALITY CONTROL
3.2.1 Testing
Government may request performance-characteristic tests on assembled lockers in accordance with FS AA-L-00486. Lockers not conforming will be rejected.
3.2.2 Repairing
Remove and replace damaged and unacceptable portions of completed work with new.
3.2.3 Cleaning
Clean surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner. Remove equipment, surplus materials, and rubbish from the site.
-- End of Section --