10 26 00 Amendment 0002.pdf
PDF 819 KB Posted
- Attached to
- Alert Facility and Alert Apron Federal contract opportunity
- Solicitation number
- N69450-20-R-0129
About this file
This document contains a federal construction solicitation and related project specifications. The solicitation is for the construction of an Aerospace Control Alert Facilities and Alert Apron at NAS JRB New Orleans, with a total project budget between $25-100 million. The facilities will include two aircraft shelters with drive-through capability, aircrew alert quarters with Alternate Command Post capabilities, and an entry control facility. The apron will include utilities, communications, site improvements, exterior and security lighting, fencing and gates to support parking for two alert ready aircraft. The contract will be a firm-fixed-price design-bid-build agreement for 1300 calendar days. The solicitation is openly competed and one or more line items may be subject to World Trade Organization Government Procurement Agreement or Free Trade Agreements. Accompanying specifications provide requirements for wall and door protections, including corner guards, wall panels, resilient materials, finishes and adhesives to meet indoor air quality standards.
View the file
Other files for this federal contract opportunity
Show all 50
Alert Facility and Alert Apron has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NORTHCOM CONSTRUCT ALERT APRON/FACILITIES WON: 1323108/1621243
NAS JRB NEW ORLEANS, LOUISIANA B-3 DESIGN SUBMITTAL
SECTION 10 26 00
WALL AND DOOR PROTECTION
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A240/A240M (2018) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications
ASTM D256 (2010) Determining the Izod Pendulum Impact Resistance of Plastics
ASTM D543 (2014) Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents
ASTM D635 (2014) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position
ASTM E84 (2018a) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM G21 (2015) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
GREEN SEAL (GS)
GS-36 (2013) Adhesives for Commercial Use
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS)Indoor Advantage
SECTION 10 26 00 Page 1 michelle.contestabil Typewritten Text
REVISION 1: AMENDMENT 0002
SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)
SAE J1545 (2005; R 2014) Instrumental Color Difference Measurement for Exterior Finishes, Textiles and Colored Trim
SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)
SCAQMD Rule 1168 (2017) Adhesive and Sealant Applications
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29.00 25 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00
SUBMITTAL PROCEDURES:
SD-03 Product Data
Corner Guards; G
Wall Covering/Panels; G
SD-04 Samples
Finish
SD-07 Certificates
Indoor air quality for wall covering/panels; S
Indoor air quality for adhesives; S
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality
1.3.1.1 Wall Covering/Panels
Provide sheet and high impact resistant resilient materials certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.
1.3.1.2 Adhesives and Sealants
Provide products certified to meet indoor air quality requirements by
SECTION 10 26 00 Page 2
UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this section. Provide current product certification documentation from certification body When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein..
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the project site in manufacturer's original unopened containers with seals unbroken and labels and trademarks intact. Keep materials dry, protected from weather and damage, and stored under cover.
Materials must be stored at approximately 70 degrees F for at least 48 hours prior to installation.
1.5 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.
PART 2 PRODUCTS
2.1 STANDARD PRODUCTS
To the maximum extent possible, corner guards, door and door frame protectors, wall guards (bumper guards), wall panels and wall covering must be the standard products of a single manufacturer and must be furnished as detailed. Drawings show general configuration of products required, and items differing in minor details from those shown will be acceptable.
2.1.1 Resilient Material
Provide resilient material consisting of high impact resistant extruded acrylic vinyl, polyvinyl chloride, or injection molded thermal plastic conforming to the following:
2.1.1.1 Minimum Impact Resistance
Minimum impact resistance must be 18 ft-lbs/sq. inch when tested in accordance with ASTM D256, (Izod impact, ft-lbs per sq inch notched).
2.1.1.2 Fire Rating
Fire rating must be Class 1 when tested in accordance with ASTM E84, having a maximum flame spread of 25 and a smoke developed rating of 450 or less.
Material must be rated self extinguishing when tested in accordance with ASTM D635. Material must be labeled and tested by an approved nationally known testing laboratory. Resilient material used for protection on fire rated doors and frames must be listed by the testing laboratory performing the tests. Resilient material installed on fire rated wood/steel door and frame assemblies must have been tested on similar type assemblies. Test results of material tested on any other combination of door/frame assembly will not be acceptable.
2.1.1.3 Integral Color
Colored components must have integral color and must be matched in accordance with SAE J1545 to within plus or minus 1.0 on the CIE-LCH scales.
SECTION 10 26 00 Page 3 michelle.contestabil Cross-Out michelle.contestabil Highlight
2.1.1.4 Chemical and Stain Resistance
Materials must be resistant to chemicals and stains reagents in accordance with ASTM D543.
2.1.1.5 Fungal and Bacterial Resistance
Materials must be resistant to fungi and bacteria in accordance with ASTM G21, as applicable.
2.2 CORNER GUARDS
2.2.1 Resilient Corner Guards
Corner guard units must be surface mounted type, radius formed to profile shown. Corner guards must extend from top of base to match height of top of door frames. Mounting hardware, cushions, and base plates must be furnished.
2.2.2 Stainless Steel Corner Guards
Stainless steel corner guards must be fabricated of 18 gauge thick material conforming to ASTM A240/A240M, type 302 or 304. Provide stainless steel base material that contains a minimum of 60 percent recycled content.
Provide data identifying percentage of recycled content for steel component of corner guards. Corner guards must be 7 feet high. Corner guard must be formed to dimensions shown.
2.3 WALL COVERING/PANELS
Provide wall covering/panels consisting of high impact rigid acrylic vinyl or polyvinyl chloride resilient material. Panel sizes must be 4 x 8 feet.
Submit fire rating and extinguishing test results for resilient material.
Also submit statements attesting that the items comply with specified fire and safety code requirements. Provide wall covering material used on the interior of the building (defined as inside of the weatherproofing system) that meets either emissions requirements of CDPH SECTION 01350 (use the office or classroom requirements, regardless of space type) the VOC content requirements of SCAQMD Rule 1168, or VOC content requirements of GS-36.
Provide certification or validation of indoor air quality for wall covering/panels.
2.3.1 Rigid Vinyl Acrylic Wall Covering
Wall covering thickness must be 0.040 inch.
2.4 TRIM, FASTENERS AND ANCHORS
Provide vinyl trim, fasteners and anchors for each specific installation as shown.
2.5 FINISH
Submit three samples indicating color and texture of materials requiring color and finish.
SECTION 10 26 00 Page 4
2.5.1 Stainless Steel Finish
Finish for stainless steel must be in accordance with ASTM A240/A240M, Type 302 or 304, finish number 4.
2.5.2 Resilient Material Finish
Finish for resilient material must be embossed stipple texture with colors in accordance with SAE J1545.
2.6 ADHESIVES
Adhesive for resilient material must be in accordance with manufacturers recommendations. Provide sealants and non-aerosol adhesive products used on the interior of the building (defined as inside of the weatherproofing system) that meet either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) the VOC content requirements of SCAQMD Rule 1168, or VOC content requirements of GS-36. Provide certification or validation of indoor air quality for adhesives.
2.7 COLOR
Color must be in accordance with the drawings. Color listed is not intended to limit the selection of equal colors from other manufacturers.
PART 3 EXECUTION
3.1 INSTALLATION
Do not install items that show visual evidence of biological growth.
3.1.1 Corner Guards and Wall Guards (Bumper Guards)
Material must be mounted at location indicated in accordance with manufacturer's recommendations.
3.1.2 Stainless Steel Guards
a. Mount guards on external corners of interior walls, partitions and columns as shown.
b. Where corner guards are installed on walls, partitions or columns finished with plaster or ceramic tile, anchor corner guards as indicated . Coat back surfaces of corner guards, where shown, with a non-flammable, sound deadening material. Corner guards must overlap finish plaster surfaces.
c. Where corner guards are installed on exposed structural glazed facing tile units or masonry wall, partitions or columns, anchor corner guards as indicated . Grout spaces solid between guards and backing with portland cement and sand mortar.
d. Where corner guards are installed on gypsum board, clean surfaces and anchor guards with a neoprene solvent-type contact adhesive specifically manufactured for use on gypsum board construction. Remove excess adhesive from the guard edges and allow to cure undisturbed for 24 hours.
SECTION 10 26 00 Page 5
-- End of Section --