A352 - SHELTER_ BUILDING SECTIONS Amd 0002.pdf
PDF 146 KB Posted
- Attached to
- Alert Facility and Alert Apron Federal contract opportunity
- Solicitation number
- N69450-20-R-0129
About this file
This solicitation seeks design-build construction services for an Alert Facility and Alert Apron at Naval Air Station Joint Reserve Base New Orleans. Key requirements include the construction of two aircraft shelters with drive-through capability, aircrew alert quarters with Alternate Command Post capabilities, a secure area, and entry control facility. The Alert Apron scope includes utilities, communications support, site improvements, exterior lighting, security upgrades, a parking apron for two alert ready aircraft, security fencing and gates, airfield lighting, security lighting and communications infrastructure. The contract will be a firm-fixed-price design-build agreement with a total project magnitude between $25-100 million and a contract completion schedule of 1300 calendar days from award. The solicitation is unrestricted and open to all responsible sources. The Department of the Navy Naval Facilities Engineering Command is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 50
Alert Facility and Alert Apron has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FINISH_FLOOR
0'-0"
T.O.P. EAVE
33'-5"
T.O.P. EAVE
33'-5"
HEF EAVE
14'-0"
S1 S2 S3 S4
T.O.P. RIDGE
36'-8"
T.O.P. RIDGE
36'-8"
TRANSITION ZONE
38'-4"
TRANSITION ZONE
38'-4"
AIRCRAFT BAY #3
304AIRCRAFT BAY #4
1' -8
3'
-3
LI
N
E O
F M
IN
. F
R
AM
IN
G
H
EI
G H
T
'-9
/8
3' -0
LI
N E
O F
M
IN
. O
PE
N
IN
G H
EI
G
H T
'-9
/8
7' -0
LI
N E
O F
PL
AN
E H
EI
G
H T
'-9
/8
'-0
76' - 8" 76' - 8" 12' - 0"
CONCRETE
SEALANT ON SLAB
PEMB STEEL COLUMN
OPENING BEYOND
PREFINISHED GUTTER
AND DOWNSPOUT
METAL SIDING
LOW PROFILE RIDGE CAP
PREFINISHED
( LOW SLOPE DESIGNED)
STANDING SEAM ROOF
PEMB STEEL COLUMN
GIRTS
PURLINS
HM DOORS
'-4
" A353
BIRD SCREEN
TYP @ ROOF
STRUCT
A502 C3
A502 B3
T/HEF CMU WALL
16'-0"
BIRD SCREEN
TYP @ ROOF
STRUCT
FINISH_FLOOR
0'-0"
T.O.P. EAVE
33'-5"
SA SB SC SESD
T.O.P. RIDGE
36'-8"
16'-11" 25'-0" 25'-0" 16'-11"
AIRCRAFT BAY #3
CONCRETE SEALANT ON SLAB
PEMB STEEL COLUMN
BEYOND -TYPICAL
METAL SIDING
PREFINISHED
( LOW SLOPE DESIGNED)
STANDING SEAM ROOF
BIRD SCREEN
TYP @ ROOF
STRUCT
A502
A502 A2
T/HEF CMU WALL
16'-0"
CAPTIVATION REQUIREMENTS
HIGH NOISE LEVEL, CHARACTERISTIC OF JET ENGINES, PRODUCES
HIGH VIBRATING FORCES
WHICH MAY RESULT IN THE LOOSENING OFA
SCREWS, BOLTS, NUTS AND FASTENERS. THE
HIGH VOLUME OF AIR MOVEMENT CAN DRAW THESE LOOSENED ITEMS
INTO JET ENGINES (POSSIBLY DESTROYING THE ENGINE OR INJURING
PERSONNEL). CAPTIVATION METHODS ARE NECESSARY TO PREVENT
THESE ITEMS FROM LOOSENING. THE REQUIREMENTS ARE
AS FOLLOWS:
1) THREADED PARTS OF INTERIOR EXPOSED
BOLTED OR SCREWED CONNECTIONS AND B
FASTENERS FOR THE BUILDING SIDING,
ANCHOR BOLTS, EQUIPMENT AND ACCESSORIES IN THE ALERT
SHELTER SHALL BE COATED WITH GE SILICONE RTV 1O8 OR
APPROVED EQUAL.
2) THREADED CONNECTIONS OF FITTINGS OR DEVICES OF PIPING
AND TUBING SYSTEMS, SUCH AS COUPLINGS, NIPPLES, UNIONS, CAPS,
PLUGS, ETC. SHALL BE COATED WITH GE SILICONE RTV 108 OR
APPROVED EQUAL.
3) THREADED CONDUIT CONNECTIONS AT COUPLINGS, FIXTURES,
JUNCTION BOXES, DEVICES, ETC. SHALL BE COATED WITH GE SILICONE
RTV 108 OR APPROVED EQUAL.
4) THREADED PARTS OF CONNECTIONS OF HANGERS AND
SUPPORTS FOR EQUIPMENT, PIPING AND CONDUIT SHALL BE COATED
WITH GE SILICONE RTV 108 OR APPROVED EQUAL
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 5 APRIL 2012
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DE
PA
RT
ME
NT
O
F
TH
E
NA
VY
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
C
OM
MA
ND
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
S O
U
TH
EA
ST
NA
VA
L A
IR
S
TA
TI
ON
JA
CK
SO
NV
ILL
E
SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
B-3 SUBMITTAL 02/28/2020
DESIGN MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
PROJECT MANAGER
ANTHONY DISANTO
Michelle Contestabile
HOLLY KING
JOANNE DIZ
1/8" = 1'-0"
IP
T
SO
U
TH
EA
ST
1621243
N69450-XX-C-XXXX
A352
NO
RT
HC
O
M R
EP
LA
CE
A
LE
RT
C O
M
PL
EX
SH
EL
TE
R
BU
IL
D
IN
G
S
EC
TI
O
N S
N
AS
J R
B N
EW
O
R
LE
AN
S
BE
LL
E C
H
AS
SE
, L
O U
IS
IA
N A
47 164
AM
EN
D
M
EN
T
/2 1/
15135288
1/8" = 1'-0"A352
3 SHELTER #2 BUILDING SECTION
1/8" = 1'-0"A352
4 SHELTER#2 BUILDING SECTION
| Sheets |
| A201 - ACQ & ECP EXTERIOR ELVATIONS |
| A351 - SHELTER #1 BUILDING SECTIONS |
| A352 - SHELTER #2 BUILDING SECTIONS |
| A353 - SHELTER WALL SECTIONS |
| A601 - DOOR / WINDOW ELEVATIONS & DOOR SCHEDULE |
| A602 - DOOR, WINDOW & LOUVER DETAILS |
File details come from the government source that posted it. Updated .