This document provides an inventory of emergency standby generators and water pumps located across Naval Air Weapons Station China Lake facilities. It lists over 100 generators and pumps by location, type, quantity and notes. The generators are primarily diesel-fueled with some propane or gas-powered. Brands include Onan, John Deere, MTU Detroit, Kohler and others. Preventative maintenance is required at least monthly to inspect engine and related components per manufacturer recommendations and ensure permit compliance. The solicitation seeks base operation support services at Naval Air Weapons Station China Lake, California, to perform reliability inspections and maintenance on the generators and pumps inventoried in the attachment, including transportation, labor and materials during regular business hours. Inspections and maintenance tasks are detailed.

Attachment_J-1502000-06_Facilities_Investment_-_Generator_Types.pdf

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT J-1502000-06

EMERGENCY STANDBY GENERATOR INVENTORY

1. EMERGENCY STANDBY GENERATOR AND WATER, FUEL PUMP INVENTORY

[BY CUSTOMER]

INVENTORY FOR DECA

BLDG LOCATION TYPE QTY COMMENTS

02023 NEX COMMISSARY EM. GEN (Diesel) 1 unknown

TOTAL 1

INVENTORY FOR BMC

BLDG LOCATION TYPE QTY COMMENTS

01403 DISPENSARY WEST SIDE EM. GEN (Diesel) 1 Unknown

TOTAL 1

INVENTORY FOR NAVAIR

BLDG LOCATION TYPE QTY COMMENTS

NWCF INVENTORY

01341 MICHELSON LAB COMPOUND EM. GEN (Diesel) 1 Unknown

00001

ADMINISTRATION BLDG. NORTH

SIDE

EM. GEN (Diesel) 1 Onan DGDA-

5704102 00005 MICHELSON LAB COMPOUND EM. GEN (Diesel) 1 2000 Gallons

20242 HANGER 4 EM. GEN (Diesel) 1 Onan

250L334193 00002 TELE COMMUNICATIONS EM. GEN (Diesel) 1 Onan

70015 RANDSBURG WASH H.Q.

WTR PUMP

(Diesel)

1 ENGINE NO 2

20242 HANGER #4 & 5

WTR PUMP

(Diesel)

ENGINE NO 1

ENGINE NO 2

ENGINE NO 3

LTF Site Fire Pump 1

SUBTOTAL 10

MRTFB INVENTORY

BLDG LOCATION TYPE QTY COMMENTS

31247 ONAN QUITE SITE/GROUND RADIO EM. GEN (Diesel) 1 Onan

31547

RANGE CONTROL CENTER, WEST

SIDE OF BUILDING

EM. GEN (Diesel) 1 unkown

SEA

SITE 1

RANDSBURY WASH

WTR PUMP

(Diesel)

1 ENGINE NO. 1

SEA

SITE 3

RANDSBURG WASH

WTR PUMP

(Diesel)

1 ENGINE NO. 1

SUBTOTAL 4

INVENTORY FOR NAVFAC (NWCF)

BLDG LOCATION TYPE QTY COMMENTS

02676 PUBLIC WORKS BULK FUEL TANKS EM. GEN (Diesel) 1 John Deere

PW

compound

2MW Genet Serial #X17D153710 Diesel 1 Type P.1734F1

01103 FH Pump House

EMER GEN

(Diesel)

MTU Detroit

363CSL1607-11

01111 “B” MOUNTAIN PUMP STATION

WTR PUMP

(Diesel)

1 ENGINE NO. 1

OUTSIDE SUPERIOR VALLEY EM GEN (diesel) 1 Kohler

250RE0ZJD

OUTSIDE DARWIN WASH EM GEN (diesel) 1 Kohler

300REZXB

14050 “B” MOUNTAIN PUMP STATION

WTR PUMP

(Diesel)

1 ENGINE NO. 2

70036 RANDSBURG WASH EM GEN (diesel) 1 Unknown 33056 Junction Ranch EM GEN (propane) 1 Kohler

250REZXB

20132 Intermediate EM GEN (Gas) 1 Unknown

TOTAL 11

INVENTORY FOR REGION-ST

BLDG LOCATION TYPE QTY COMMENTS

00878

FIRE STATION #1 WEST SIDE OF

PARKING LOT

EM. GEN (Diesel) 1 Olympian D150P4

20169 NAF TACAN RUNWAY APEX EM. GEN (Diesel) 1 Kohler 80R0Z81

20007 NAF BOLIER PLANT #3 EM. GEN (Diesel) 1 MTU Detroit

250JC6DT3

FOTS GENERATOR MICHELSON

LABORATORY WEST COMPOUND

EM. GEN (Diesel) 1 Unknown

20007 NAF PUMP HOUSE

WTR PUMP

(Diesel)

ENGINE NO 1

ENGINE NO 2

ENGINE NO 3

ENGINE NO 4

ENGINE NO 5

70005 RANDSBURG WASH H.Q.

WTR PUMP

(Diesel)

1 ENGINE NO 1

20286 AVIATION FUEL FARM

WTR PUMP

(Diesel)

1 ENGINE NO 1

01327 B-Mountain EM. Gen (Propane) 1 Unknown

33074 DARWIN WASH GEN(Diesel) 1 Unknown

01182 MAIN GATE EM. GEN (Diesel) 1 Marathon

431CSL6202

14060 Seabees Mineral Rock Plant Kohler(Diesel)36k

Generator

Kohler Decision maker 3500

Armitage Field

Runways RCM-D Runway

Emergency Markers

Hali-Brite Runway Markers

01384 Paradise Café EM. Generator 1 Kohler 350k

TOTAL 18

INVENTORY FOR EOD

BLDG LOCATION TYPE QTY COMMENTS

33060 EOD Training Facility EM. GEN (Diesel) 1 Unknown 33060 EOD Training Facility Pump diesel 1 Unknown

TOTAL 2

INVENTORY FOR DLA/DAPS

LOCATION TYPE QTY COMMENTS

20268 Fuel Farm Generator 1 Gillett Model

SPVD-3000-3-4-3

Serial # PC-8-303

2. PREVENTIVE MAINTENANCE PROGRAM FOR EMERGENCY GENERATORS

AND WATER TRANSFER/WELL PUMPS

There shall be no less than a monthly check and service of engine and related components, which shall include, but not limited to, batteries, oil, coolant system, exhaust system, fuel system, control systems, etc., and other checks and services as recommended by unit manufacturer. For those engines requiring a Permit to Operate, ensure the engine exhaust is in compliance with permit limits.

An SRO will be initiated for each inspection and all work resulting from the inspection:

INCLUSIONS: Contractor will perform the following Reliability Inspections & Maintenance Services, to include transportation, labor, and materials for work performed during regular business hours.

Inspection of engine/generator controller for defects. Clean controller and check connections.

Check all fluid levels and top off as necessary. (Refueling is not included). Inspect fuel tank, day tank, fuel lines and fittings for defects. Repair if minor.

Check equipment for any fuel, coolant, and or oil leaks. Tighten fittings as necessary.

Inspect all engine drive belts, pulleys and hoses for defects. Adjust belts if necessary.

Inspect the radiator fan, shroud, and radiator core fins for restrictions, cleanliness and or defects.

Inspect block heaters for proper operation.

Inspect the exhaust system for any cracked or broken parts. Tighten all mounting as necessary.

Inspect the fuel injection pump, transfer pump and governor system for defects.

Check and clean batteries to include terminals. Check electrolyte and specific gravity levels. Apply terminal preservative.

Check battery cables and connections. Inspect auxiliary battery charger for proper operation. Adjust as necessary.

Check air cleaners and filters for any restrictions or defects. Clean as necessary.

Check turbo charger for tolerance and freedom of movement.

Inspect the generator main circuit breaker for loose connections and heat marks.

Inspect generator alternator for heat and wear. Blow dust out of stator. Inspect bearing if possible.

Check electrical wiring for signs of abrasion, chaffing, and or corrosion at connectors.

Inspect the transfer switch for any defects. Ensure the exercise clock is operational and is set to the customer specific time for exercise. Lubricate mechanical parts if possible.

The engine, radiator, and adjacent area shall be clean and a check performed to ensure proper operation of engine heater/heater exchanges.