Attachment M - F76 6_PIER3_REFERENCE-DRAWINGS_SET_6-OF-6.pdf

PDF 23 MB Posted

Attached to
P919 - Phase I, Bulk Fuel Tank Farm Improvements, Naval Station Rota, Spain
Solicitation number
N6247026R0006
Issued by

About this file

This document is a comprehensive topographic and engineering survey package for the construction of a new pipeline (potable water system) in Puerto Real, Cádiz, Spain. The survey was conducted by Grupo Prisma, C.B. in December 2000 and includes detailed mapping of underground utilities, existing structures, and site conditions across multiple survey areas.

The package contains extensive survey benchmark information with multiple reference points (FP1, FP2, BP-O, BP-E, BR-1, FP10, FP11, A3, A2, and H3) establishing elevations and coordinates relative to mean sea level at Alcante. The survey encompasses approximately 19 enlarged survey areas with detailed topographic plans at 1:250 scale, showing pipe routing through various terrain types and identifying existing utilities including water lines, sanitary sewer pipes, electrical lines, and communications infrastructure. Additional materials include boring location maps with work notes, soil profile data with geotechnical classifications, laboratory test results (consolidation, expansion index, compressive strength, and soil aggressiveness), and detailed piping schematic diagrams for valve pits and booster pump house installations. The survey also documents existing conditions at the Rio Salado river crossing and includes electrical reference drawings showing power cable flow diagrams, panel schedules, and instrumentation details for Pier 3 meter run installations and valve pit configurations. Grading analysis and material passing sieve 200 data are provided, along with standard penetration test (SPT) results and Atterberg limits documentation for foundation design purposes.

View the file

Other files

File Type Posted
N6247026R0006 Amendment 0009.pdf PDF
N6247026R0006 Amendment 0008.pdf PDF
Amendment 0008 Revised Specifications_Section 01.pdf PDF
P919 - Amendment 0007.pdf PDF
N6247026R0006 Amendment 0007.pdf PDF
Amendment 0006_Revised Specifications P919.pdf PDF
Amendment 0006_Revised Specifications F76 Pier 3.pdf PDF
Attachment M - F76 5_PIER3-FINAL_SUBMITTAL-PGS-130-149_SET_5-OF-6.pdf PDF
Amendment 0006_Revised Tank DWGs Prime.pdf PDF
Attachment M - F76 3_PIER3-FINAL_SUBMITTAL-PGS-62-99_SET_3-OF-6.pdf PDF
Amendment 0006_Revised F76 Pier 3 Mech Dwgs.pdf PDF
Attachment M - F76 4_PIER3-FINAL_SUBMITTAL-PGS-100-129_SET_4-OF-6.pdf PDF
Amendment 0006_Revised P-919 Dwgs_Pipeline Dwgs.pdf PDF
N6247026R0006 Amendment 0006.pdf PDF
Attachment M - F76 2_PIER3-FINAL_SUBMITTAL-PGS-35-70_SET_2-OF-6.pdf PDF
Attachment M - F76 1_PIER3-FINAL-REV1_SUBMITTAL-PGS-1-34_SET_1-OF-6.pdf PDF
Amendment 0006_Revised 01 30 00.pdf PDF
Amendment 0006_Revised F76 Pier 3 Civil Dwgs.pdf PDF
P919 - Amendment 0006.pdf PDF
Amendment 0006_Revised EC502P CATHODIC PROTECTION DETAILS.pdf PDF
Amendment 0006_Revised 01 45 00.pdf PDF
Amendment 0006_Revised 01 35 26.pdf PDF
Attachment G - Certificate of Classification Revised.pdf PDF
P-919 - Amendment 0005.pdf PDF
N6247026R0006 Amendment 0005.pdf PDF
Attachment P - Photos.pdf PDF
N6247026R0006 Amendment 0004.pdf PDF
N6247026R0006 Amendment 0003.pdf PDF
P919 Amendment 0002.pdf PDF
Site Visit Log (Attachment O).pdf PDF
N6247026R0006 Amendment 0002.pdf PDF
Attachment B - Bid Schedule Revised.pdf PDF
N6247026R0006 Amedment 0001.pdf PDF
Attachment N - Specifications -Replace Fuel Pipeline Pier 3 Rota.pdf PDF
Attachment M - F74 4_PIER3-FINAL_SUBMITTAL-PGS-100-129_SET_4-OF-6.pdf PDF
Attachment M - F74 5_PIER3-FINAL_SUBMITTAL-PGS-130-149_SET_5-OF-6.pdf PDF
Attachment M - F74 6_PIER3_REFERENCE-DRAWINGS_SET_6-OF-6.pdf PDF
Attachment M - F74 2_PIER3-FINAL_SUBMITTAL-PGS-35-70_SET_2-OF-6.pdf PDF
Attachment M - F74 3_PIER3-FINAL_SUBMITTAL-PGS-62-99_SET_3-OF-6.pdf PDF
Attachment M - F74 1_PIER3-FINAL-REV1_SUBMITTAL-PGS-1-34_SET_1-OF-6.pdf PDF
Attachment_F_P919__Volume_12_of_15.pdf PDF
Attachment_F_P919__Volume_2_of_15.pdf PDF
Attachment_F_P919__Volume_9_of_15.pdf PDF
Attachment_F_P919__Volume_1_of_15.pdf PDF
Attachment L - Certificate Insurance Form.pdf PDF
Attachment_F_P919__Volume_7_of_15.pdf PDF
Attachment G - Certificates of Classifications.pdf PDF
Attachment_F_P919__Volume_14_of_15.pdf PDF
Attachment D - Construction Experience Project Data Sheet.pdf PDF
Attachment_F_P919_REFERENCE_Volume_15_of_15.pdf PDF
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rectangle

Text Box

ELECTRICAL REFERENCE DRAWINGS

PIER 3 PIT VP-1

Text Box

Text Box

Text Box

Text Box

PIER 3 BPH-VP-3 & 3.5

Text Box

PIER 3 RIO SOLADO RIVER CROSSING EAST SIDE

Text Box

Text Box

Text Box

PIER 3 BPH-VP-3 & PIER 3 RIO SOLADO RIVER CROSSING EAST SIDE

ELECTRICAL REFERENCE DRAWINGS.pdf
Pier 3 VP 1 Reference
103201-5 T21
103201-9 P8
103201-11 E3
103201-3 PD24
103201-3 PD31
Rio SOLADA EAST reference files
103201-05 T19
103201-9 P6
103201-11 E4
103201-3 PD40

File details come from the government source that posted it. Updated .