This solicitation is for the construction of Phase 2 of the Family Housing Villaggio at Vicenza, Italy. The Navy is seeking offers for work including site preparation, utilities infrastructure, buildings, roads and playgrounds.
Key details include a base bid for site work, utilities and buildings, along with eight optional bid items for additional amenities. Offerors must submit pricing using the Schedule B price proposal form by February 25, 2022. The statutory cost limitation for the project is $73,050,000. The contract will have a performance period of 800 days from the notice to proceed. Small businesses and HUBZone, service-disabled, and women-owned small businesses will receive preferences in evaluation. The solicitation includes specifications, drawings and responses to offeror questions to aid in proposal preparation.
View the file
Other files
Show 40 more
Latest 50 of 66 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
MILCON PROJECT P-91330, PHASE 2 FAMILY HOUSING VILLAGIO AT VICENZA, ITALY
Please see Section SF 30 Block 14 Continuation Page.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 28
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 27-Jan-2022
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6247021R0015
X 9B. DATED (SEE ITEM 11)
27-Oct-2021
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
27-Jan-2022
CODE
COMNAVFACSYSCOM ATLANTIC
6506 HAMPTON BLVD
NORFOLK VA 23508-1278
N62470 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N6247021R0015
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been added by full text:
AMENDMENT 0006
The purpose of this amendment is for the following items:
1. Extend the proposal due date
2. Responses to Pre-Proposal Inquiries (PPIs)
3. Solicitation Revisions
4. Specification and Drawing Revisions
5. Provide Attachments
1. The proposal due date is extended from Monday, 07 February 2022 at 2:00 PM Eastern Standard Time to
Friday, 25 February 2022 at 2:00 PM Eastern Standard Time.
2. Responses to PPIs
PPI
No.
REFERENCE QUESTION GOVERNMENT RESPONSE
Page Section Para.
13 About rules and regulation, which has priority, NFPA or Italian regulation? Please advise
The most restrictive of the two must govern.
14 SPECIFICATIONS, Contractor's Facilities.
Please clarify which Facilities, such as offices and storages, will be made available to the Contractor within the site area and at which rates.
Propose in accordance with the solicitation. Refer to Drawing Sheet C-005 and Specification Sections 01 14 00 & 01 50 00.
There is no cost to Contractor for use of Government provided facility.
15 DEMOLITION WORKS. The information provided in the drawings do not allow a full understanding of the scope of work and a correct estimation. We do not find details about materials and dimensions.
All available existing building and utility information is indicated in the solicitation. Refer to Hazardous Material Sheets H001, and H-101 through H-105. Also refer to Civil Demolition Sheets CD001, and CD101 through CD117. Also refer to Specification Sections 02 41 00 DEMOLTION, and 02 82 00 ASBESTOS REMEDIATION. In particular, refer to HAZMAT Report attached at end of section 02 82 00.
16 Scope of work - Please confirm that all home furnishings and kitchen equipment are not included in the Contractor's scope of work. Please confirm that casework and lighting systems are included instead.
Refer to Amendment detail below.
17 1.
CLIN
0002, CLIN
0004, CLIN
0006, CLIN
Please may you confirm that the “Rouladen Shades” are the rollers (and relevant boxes) described in the drawing A540?
Rouladen Shades are Specified in Section 10 71 13.13 EXTERIOR SHUTTERS. Refer to Paragraph
1.7. Confirmed, “Rouladen
Shades" are the Roller (and relevant Boxes) described in the drawings on Sheet A-540 entitled “Roller Blind Detail Bid Option”.
Refer to Amendment detail below, drawing A-540 from “Roller Blind Detail Bid Option” to “ Exterior Shutters Bid Option”
18 CLIN
Such option includes only “Venezia Neighborhood playground”; what about all other playgrounds (such as “Milano Neighborhood playground”, LS402, for example)? Shall we include them into our offer? And, in case of positive answer, which is/are the relevant CLIN/CLINS?
Propose in accordance with the solicitation. Only the Venezia Neighborhood playground is segregated into a separate Contract Line Item Number (CLIN 0009).
Other playgrounds are included within CLIN 0001AC for Site Work.
19 5; 15. Solicitation We request confirmation that both the Solicitation Section 00 10 00 and the Schedule B, Price Proposal Form shall be priced, even though solicitation section 00 10 00 includes only CLINs CLIN 0001AA, CLIN
0001AB, CLIN 0001AC.
Propose in accordance with the solicitation. Refer to Section 3.2.1 Basis of Evaluation and Submittal Requirements for Each Factor, Price. Offerors are required to submit a Completed Schedule B, Price Proposal Form.
20 5; 15. Solicitation With reference to the following : "In accordance with FAR 36.205, the statutory cost limitation is $73,050,000 USD for P-91330, Phase 2 Family Housing Villaggio at Vicenza, Italy. [...] Statutory cost limitation applies to all CLINs." We would like to request confirmation that the CLINs to which the statutory cost limitation applies to are those listed in Section 00 10 00 of the solicitation, i.e. CLINs CLIN
0001AA, CLIN 0001AB, CLIN
0001AC. Moreover, we kindly ask if a cost limitation applies to the option CLINs (option items 1 through 8).
Refer to Solicitation 1.1.4. The Statutory Cost Limitation applies to all CLINs.
3. Solicitation Revisions
CURRENT:
5. ATTACHMENTS: Will be located on Contract Opportunities under additional documents.
5.1 PRE-PROPOSAL INQUIRY FORM (ATTACHMENT A)
5.2 SEC-NAV_5512_1_11787 FORM (ATTACHMENT B)
5.3 CONSTRUCTION EXPERIENCE PROJECT DATA SHEET (ATTACHMENT C)
5.4 PAST PERFORMANCE QUESTIONNAIRE (ATTACHMENT D)
5.5 SCHEDULE B PRICE PROPOSAL FORM (ATTACHMENT E)
5.6 LRA COMMERCIAL VEHICLE INSPECTION PROCEDURES (ATTACHMENT F)
5.7 SPECIFICATIONS (ATTACHMENT G)
5.8 DRAWINGS (24 TOTAL) (ATTACHMENT H)
5.9 UXO REPORT (ATTACHMENT I)
5.10 PSC ITALIAN (ATTACHMENT J)
5.11 DWG INDEX (ATTACHMENT K)
REVISED TO:
5. ATTACHMENTS: Will be located on Contract Opportunities under additional documents.
5.1 PRE-PROPOSAL INQUIRY FORM (ATTACHMENT A)
5.2 SEC-NAV_5512_1_11787 FORM (ATTACHMENT B)
5.3 CONSTRUCTION EXPERIENCE PROJECT DATA SHEET (ATTACHMENT C)
5.4 PAST PERFORMANCE QUESTIONNAIRE (ATTACHMENT D)
5.5 SCHEDULE B PRICE PROPOSAL FORM (ATTACHMENT E)
5.6 LRA COMMERCIAL VEHICLE INSPECTION PROCEDURES (ATTACHMENT F)
5.7 SPECIFICATIONS (ATTACHMENT H)
5.8 DRAWINGS (24 TOTAL) (ATTACHMENT I)
5.9 UXO REPORT (ATTACHMENT J)
5.10 PSC ITALIAN (ATTACHMENT K)
5.11 DWG INDEX (ATTACHMENT L)
CURRENT:
2.2.3 PERFORMANCE GUARANTEE:
PERFORMANCE GUARANTEE
Ten-Percent (10%) PERFORMANCE GUARANTEE
Submittal Time: The offeror whose offer is accepted shall, within ten (10) days after Administering Contracting Officer (ACO) transfer notice, furnish either (1) a Performance Guarantee and a notarized Performance Guarantee Letter conforming to the requirements below, or (2) Performance and Payment bonds conforming to the requirements below. If the offeror fails to provide either (1) a Performance Guarantee and a notarized Performance Guarantee Letter or (2) Performance and Payment Bonds within ten (10) days, the contract may be terminated for default. In such event, the offeror shall be liable for any cost of procuring the work which exceeds the amount of its offer.
Clauses 52.228-2, 52.228-11 and 52.228-15, listed in Section 01 00 00 – General Requirements below, will apply only if the offeror elects to submit payment and performance bonds, rather than a notarized performance guarantee, with their proposal.
Form of Performance Guarantee: The Performance Guarantee shall be an amount equal to ten percent (10%) of the amount of the contract and shall be deposited into a banking institution, as acceptable to the Contracting Officer, which will then issue an irrevocable letter guaranteeing (the “Performance Guarantee Letter”) the payment of the amount deposited to the United States Government, upon demand by the Contracting Officer. Demand may be made if the Contractor fails to comply with the terms and conditions of the contract, or does not fulfill its undertaking in whole or in part. Payment to the Contracting Officer will be by check made payable to the "United States of America by the U.S.
Department of the Navy, Naval Facilities Engineering Systems Command, Europe, Africa, Central."
The Performance Guarantee shall take effect upon the date of signature of the Performance Guarantee Letter and shall remain valid and irrevocable until one (1) year after the work has been finally inspected and accepted by the Government. The Performance Guarantee Letter shall be accompanied by a notarized document authenticating the financial institution's authority to sign the letter. An English translation of the Performance Guarantee Letter shall be submitted concurrently.
Upon acceptance of all work by the Government, however, the Contractor may, with the approval of the Contracting Officer, replace this guarantee with a reduced guarantee in the amount of four percent (4%) of the then existing contract price, with modifications, if any. Such replacement guarantee will then remain in effect for one (1) year after the final acceptance of the work by the Government.
SAMPLE OF PERFORMANCE GUARANTEE ISSUED BY A BANK
The Government will accept as valid a Performance Guarantee conforming to these requirements.
BANK LETTERHEAD
Date To: United States of America U.S. Department of Navy Contracting Office (FEA/IPT put in your address)
Attention: Contracting Officer
This is a letter of performance guarantee. I/We, the undersigned, acting as the duly authorized representative(s) of the Bank, declare that the Bank hereby guarantees and is jointly and severally liable as guarantor with the contractor named below to effect payment to the Contracting Office that issued the contract stated below, by check made payable to the “United States of America by the U.S. Department of the Navy, Naval Facilities Engineering Systems Command, Europe, Africa, Central,” within five (5) calendar days after receipt of a simple written request by registered mail, return receipt, in amount up to sum of (Amount equal to ten (10%) percent of the contract amount in the currency stated in the contract), which represents the deposit required of the Contractor to guarantee fulfillment of his obligations for the satisfactory completion and timely performance of the work under Contract No. (insert contract number) for (insert description of services and location), in strict compliance with the terms, conditions and specifications of said contract entered into between the United States of America by the U.S. Department of Navy, Naval Facilities Engineering Systems Command, Europe, Africa, Central and the Contractor (insert name of Contractor) on (insert contract date), plus legal interest to be calculated from the date of receipt of the registered letter of request by the Contracting Officer to the date of actual payment, without any need for the Contracting Officer to take any legal action or obtain the prior consent of the Contractor, or for any other proof, action or decision by any other authority. The request by the Contracting Officer shall simply inform the Bank that the Contractor failed to comply with the terms and conditions of the contract, or did not fulfill his undertaking in whole or in part.
I/We agree and consent that said contract may be modified by change order or supplemental agreement affecting the amount or the period of performance of the contract without prior consent of the Bank and without affecting the validity of this guarantee; provided, however, that the amount of this guarantee shall remain unchanged.
This letter of performance guarantee will continue in effect without change in amount or terms until one year after the work has been finally accepted by the Government through its Contracting Officer’s legal representative.
(BANK NAME & ADDRESS) (CONTRACTOR NAME & ADDRESS)
Signed by: Signed by:
(Typed name) (Typed name)
(Title) (Title)
(This Performance Guarantee shall be accompanied by a notarized document authenticating the bank agent’s authority to sign the letter of performance guarantee for the bank company.)
Optional Performance and Payment Bonds: In lieu of a performance guarantee, the offeror may submit Performance and Payment Bonds in which the offeror and the surety obligate themselves in the amount of one hundred percent (100%) of the contract price, that the offeror shall undertake the performance of the contract if it receives award, shall make all required payments to subcontractors, and that said Performance and Payment Bonds ensure the fulfillment of all agreements contained in the contract. To be considered for acceptability, the offeror(s) shall submit Performance and Payment Bonds that meet the following requirements:
(a) The bonds shall be furnished within 10 days after receipt of ACO transfer notice and shall each be in a penal sum equal to 100% of the contract price;
(b) The bonds shall be from a bank or other financial institution, either of which must first be approved by the Contracting Officer; and
(c) The bonds shall be of the U.S. standard type or of another type approved by the Contracting Officer and shall include the following concepts: (1) name of Surety and name of agent signing in behalf of Surety; (2) name of Principal; (3) a statement that the Principal and Surety are firmly bound on the United States of America in the penal sum of the bond; (4) Contract number; (5) Penal sum of bond and the statement "This bond will be in force until the Contracting
Officer of the above-cited Contract authorized cancellation of the bond"; and (6) date of issuance of bond and signature of Surety's agent.
Contract Timing: Regardless of when performance and payment bonds or the Performance Guarantee and Performance Guarantee Letter are provided, the contract time for purposes of fixing the completion date, default, and liquidated damages shall begin to run 800 days from the notice to proceed.
REVISED TO:
2.2.3 PERFORMANCE GUARANTEE:
PERFORMANCE GUARANTEE
Ten-Percent (10%) PERFORMANCE GUARANTEE
Submittal Time: The offeror whose offer is accepted shall, within ten (10) days after Administering Contracting Officer (ACO) transfer notice, furnish either (1) a Performance Guarantee and a notarized Performance Guarantee Letter conforming to the requirements below, or (2) Performance and Payment bonds conforming to the requirements below. If the offeror fails to provide either (1) a Performance Guarantee and a notarized Performance Guarantee Letter or (2) Performance and Payment Bonds within ten (10) days, the contract may be terminated for default. In such event, the offeror shall be liable for any cost of procuring the work which exceeds the amount of its offer.
Clauses 52.228-2, 52.228-11 and 52.228-15, listed in Section 01 00 00 – General Requirements below, will apply only if the offeror elects to submit payment and performance bonds, rather than a notarized performance guarantee, with their proposal.
Form of Performance Guarantee: The Performance Guarantee shall be an amount equal to ten percent (10%) of the amount of the contract and shall be deposited into a banking institution, as acceptable to the Contracting Officer, which will then issue an irrevocable letter guaranteeing (the “Performance Guarantee Letter”) the payment of the amount deposited to the United States Government, upon demand by the Contracting Officer. Demand may be made if the Contractor fails to comply with the terms and conditions of the contract, or does not fulfill its undertaking in whole or in part. Payment to the Contracting Officer will be by check made payable to the "United States of America by the U.S.
Department of the Navy, Naval Facilities Engineering Systems Command, Europe, Africa, Central."
The Performance Guarantee shall take effect upon the date of signature of the Performance Guarantee Letter and shall remain valid and irrevocable until one (1) year after the work has been finally inspected and accepted by the Government. The Performance Guarantee Letter shall be accompanied by a notarized document authenticating the financial institution's authority to sign the letter. An English translation of the Performance Guarantee Letter shall be submitted concurrently.
Upon acceptance of all work by the Government, however, the Contractor may, with the approval of the Contracting Officer, replace this guarantee with a reduced guarantee in the amount of four percent (4%) of the then existing contract price, with modifications, if any. Such replacement guarantee will then remain in effect for one (1) year after the final acceptance of the work by the Government.
The performance guarantee/performance and/or payment bonds shall be in the name of the proposed Offeror. If the Offeror is a Joint Venture (JV), the guarantee/bonds shall be in the name of the JV.
SAMPLE OF PERFORMANCE GUARANTEE ISSUED BY A BANK
The Government will accept as valid a Performance Guarantee conforming to these requirements.
BANK LETTERHEAD
Date To: United States of America U.S. Department of Navy Contracting Office (FEA/IPT put in your address)
Attention: Contracting Officer
This is a letter of performance guarantee. I/We, the undersigned, acting as the duly authorized representative(s) of the Bank, declare that the Bank hereby guarantees and is jointly and severally liable as guarantor with the contractor named below to effect payment to the Contracting Office that issued the contract stated below, by check made payable to the “United States of America by the U.S. Department of the Navy, Naval Facilities Engineering Systems Command, Europe, Africa, Central,” within five (5) calendar days after receipt of a simple written request by registered mail, return receipt, in amount up to sum of (Amount equal to ten (10%) percent of the contract amount in the currency stated in the contract), which represents the deposit required of the Contractor to guarantee fulfillment of his obligations for the satisfactory completion and timely performance of the work under Contract No. (insert contract number) for (insert description of services and location), in strict compliance with the terms, conditions and specifications of said contract entered into between the United States of America by the U.S. Department of Navy, Naval Facilities Engineering Systems Command, Europe, Africa, Central and the Contractor (insert name of Contractor) on (insert contract date), plus legal interest to be calculated from the date of receipt of the registered letter of request by the Contracting Officer to the date of actual payment, without any need for the Contracting Officer to take any legal action or obtain the prior consent of the Contractor, or for any other proof, action or decision by any other authority. The request by the Contracting Officer shall simply inform the Bank that the Contractor failed to comply with the terms and conditions of the contract, or did not fulfill his undertaking in whole or in part.
I/We agree and consent that said contract may be modified by change order or supplemental agreement affecting the amount or the period of performance of the contract without prior consent of the Bank and without affecting the validity of this guarantee; provided, however, that the amount of this guarantee shall remain unchanged.
This letter of performance guarantee will continue in effect without change in amount or terms until one year after the work has been finally accepted by the Government through its Contracting Officer’s legal representative.
(BANK NAME & ADDRESS) (CONTRACTOR NAME & ADDRESS)
Signed by: Signed by:
(Typed name) (Typed name)
(Title) (Title)
(This Performance Guarantee shall be accompanied by a notarized document authenticating the bank agent’s authority to sign the letter of performance guarantee for the bank company.)
Optional Performance and Payment Bonds: In lieu of a performance guarantee, the offeror may submit Performance and Payment Bonds in which the offeror and the surety obligate themselves in the amount of one hundred percent (100%) of the contract price, that the offeror shall undertake the performance of the contract if it receives award, shall make all required payments to subcontractors, and that said Performance and Payment Bonds ensure the fulfillment of all agreements contained in the contract. To be considered for acceptability, the offeror(s) shall submit Performance and Payment Bonds that meet the following requirements:
(d) The bonds shall be furnished within 10 days after receipt of ACO transfer notice and shall each be in a penal sum equal to 100% of the contract price;
(e) The bonds shall be from a bank or other financial institution, either of which must first be approved by the Contracting Officer; and
(f) The bonds shall be of the U.S. standard type or of another type approved by the Contracting Officer and shall include the following concepts: (1) name of Surety and name of agent signing in behalf of Surety; (2) name of Principal; (3) a statement that the Principal and Surety are firmly bound on the United States of America in the penal sum of the bond; (4) Contract number; (5) Penal sum of bond and the statement "This bond will be in force until the Contracting Officer of the above-cited Contract authorized cancellation of the bond"; and (6) date of issuance of bond and signature of Surety's agent.
Contract Timing: Regardless of when performance and payment bonds or the Performance Guarantee and Performance Guarantee Letter are provided, the contract time for purposes of fixing the completion date, default, and liquidated damages shall begin to run 800 days from the notice to proceed.
4. Specification and Drawing Revisions
SPECIFICATIONS
SECTION 01 30 00 Administration Requirements; 1.5 Minimum Insurance Requirements.
ADD: “11. The insurance policy shall be in the name of the proposed Offeror. If the Offeror is a Joint Venture (JV), the policy shall be in the name of the JV.”
SECTION 01 33 00 SUBMITTAL PROCEDURES
Delete the Submittal Register attached to the end of the section and replace with the Submittal Register accompanying this amendment.
SECTION 06 41 16.00 10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
Delete Section 06 41 16.00 10 in its entirety and insert new section 06 41 16.00 10 accompanying this amendment.
SECTION 07 42 00 RENDER SYSTEM
Delete Section 07 42 00 in its entirety and insert new section 07 42 00 accompanying this amendment.
SECTION 09 30 10 CERAMIC, QUARRY, AND GLASS TILING
Delete Section 09 30 10 in its entirety and insert new section 09 30 10 accompanying this amendment.
SECTION 10 28 13 TOILET ACCESSORIES
Delete Section 11 68 13 in its entirety and insert new section 11 68 13 accompanying this amendment.
SECTION 11 31 13 ELECTRIC KITCHEN EQUIPMENT
Delete Section 10 28 13 in its entirety and insert new section 10 28 13 accompanying this amendment.
SECTION 22 00 00 PLUMBING, GENERAL PURPOSE
Delete Section 22 00 00 in its entirety and insert new section 22 00 00 accompanying this amendment.
SECTION 26 11 20 HIGH VOLTAGE/LOW VOLTAGE (HV/LV) SUBSTATION
Delete Section 26 11 20 in its entirety and insert new section 26 11 20 accompanying this amendment.
SECTION 26 32 15.00 ENGINE-GENERATOR SET STATIONARY 15-2500 KW, WITH AUXILIARIES
Delete Section 26 32 15.00 in its entirety and insert new section 26 32 15.00 accompanying this amendment.
SECTION 27 41 16 INTEGRATED AUDIO-VIDEO SYSTEMS AND EQUIPMENT
Delete Section 32 31 19 in its entirety and insert new section 32 31 19 accompanying this amendment.
SECTION 31 23 00.00 20 EXCAVATION AND FILL
Delete Section 27 41 16 in its entirety and insert new section 27 41 16 accompanying this amendment.
SECTION 32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS
Delete Section 32 12 16 in its entirety and insert new section 32 12 16 accompanying this amendment.
SECTION 32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE
FACILITIES
Delete Section 32 13 13.06 in its entirety and insert new section 32 13 13.06 accompanying this amendment.
SECTION 33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
Delete Section 33 71 02 in its entirety and insert new section 33 71 02 accompanying this amendment.
The following drawings are revised:
NAVFAC DWG NO. Title
14091598 (G-003) INDEX OF DRAWINGS VOLUME I / ELENCO DISEGNI VOLUME I
14091599 (G-004) INDEX OF DRAWINGS VOLUME II PART I / ELENCO DISEGNI VOLUME II
PARTE I
14091600 (G-005) INDEX OF DRAWINGS VOLUME II PART II / ELENCO DISEGNI VOLUME II
PARTE II
14091601 (G-006) INDEX OF DRAWINGS VOLUME III PART I / ELENCO DISEGNI VOLUME III
PARTE I
14091602 (G-007) INDEX OF DRAWINGS VOLUME III PART II / ELENCO DISEGNI VOLUME III
PARTE II
14091603 (G-008) INDEX OF DRAWINGS VOLUME IV PART I / ELENCO DISEGNI VOLUME IV
PARTE I
14091604 (G-009) INDEX OF DRAWINGS VOLUME IV PART II / ELENCO DISEGNI VOLUME IV
PARTE II
14091935 (S-103) AP BUILDING 23400 GROUND FLOOR SLAB / PLAN PIANTA SOLAIO AP
EDIFICIO 23400 PIANO TERRA
14091946 (S-114) AP BUILDING 26200 GROUND FLOOR SLAB / PLAN PIANTA SOLAIO AP
EDIFICIO 26200 PIANO TERRA
14091997 (S-202) AP BUILDING 23400 FACADE ELEVATIONS / AP EDIFICIO 23400 PROSPETTI
FACCIATA
14091998 (S-202A) AP BUILDING 23400 FACADE ELEVATIONS BID OPTION / AP EDIFICIO 23400
PROSPETTI FACCIATA OPZIONE OFFERTA
14092003 (S-205) AP BUILDING 26200 FACADE ELEVATIONS / AP EDIFICIO 26200 PROSPETTI
FACCIATA
14092004 (S-205A) AP BUILDING 26200 FACADE ELEVATIONS BID OPTION / AP EDIFICIO 26200
PROSPETTI FACCIATA OPZIONE OFFERTA
14092017 (S-212) AP BUILDING 23400 SHEAR WALL ELEVATIONS / AP EDIFICIO 23400
PROSPETTI MURI PORTANTI
14092018 (S-212A) AP BUILDING 23400 SHEAR WALL ELEVATIONS BID OPTION /AP EDIFICIO
23400 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092019 (S-213) AP BUILDING 23400 SHEAR WALL ELEVATIONS / AP EDIFICIO 23400
PROSPETTI MURI PORTANTI
14092020 (S-213A) AP BUILDING 23400 SHEAR WALL ELEVATIONS BID OPTION / AP EDIFICIO
23400 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092021 (S-214) AP BUILDING 23400 SHEAR WALL ELEVATIONS / AP EDIFICIO 23400
PROSPETTI MURI PORTANTI
14092022 (S-214A) AP BUILDING 23400 SHEAR WALL ELEVATIONS BID OPTION / AP EDIFICIO
23400 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092027 (S-217) AP BUILDING 23400 SHEAR WALL ELEVATIONS / AP EDIFICIO 23400
PROSPETTI MURI PORTANTI
14092028 (S-217A) AP BUILDING 23400 SHEAR WALL ELEVATIONS BID OPTION / AP EDIFICIO
23400 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092059 (S-233) AP BUILDING 26200 SHEAR WALL ELEVATIONS / AP EDIFICIO 26200
PROSPETTI MURI PORTANTI
14092060 (S-233A) AP BUILDING 26200 SHEAR WALL ELEVATIONS BID OPTION / AP EDIFICIO
26200 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092061 (S-234) AP BUILDING 26200 SHEAR WALL ELEVATIONS / AP EDIFICIO 26200
PROSPETTI MURI PORTANTI
14092062 (S-234A) AP BUILDING 26200 SHEAR WALL ELEVATIONS BID OPTION / AP EDIFICIO
26200 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092063 (S-235) AP BUILDING 26200 SHEAR WALL ELEVATIONS / AP EDIFICIO 26200
PROSPETTI MURI PORTANTI
14092064 (S-235A) AP BUILDING 26200 SHEAR WALL ELEVATIONS BID OPTION / AP EDIFICIO
26200 PROSPETTI MURI PORTANTI OPZIONE OFFERTA
14092102 (S-301) AP BUILDING 23400 SECTION / AP EDIFICIO 23400 SEZIONE
14092103 (S-301A) AP BUILDING 23400 SECTION BID OPTION / AP EDIFICIO 23400 SEZIONE
OPZIONE OFFERTA
14092104 (S-302) AP BUILDING 23400 SECTION / AP EDIFICIO 23400 SEZIONE
14092105 (S-302A) AP BUILDING 23400 SECTION BID OPTION / AP EDIFICIO 23400 SEZIONE
OPZIONE OFFERTA
14092106 (S-303) AP BUILDING 23400 SECTIONS / AP EDIFICIO 23400 SEZIONI
14092107 (S-303A) AP BUILDING 23400 SECTIONS BID OPTION / AP EDIFICIO 23400 SEZIONI
OPZIONE OFFERTA
14092114 (S-307) AP BUILDING 26200 SECTION / AP EDIFICIO 26200 SEZIONE
14092115 (S-307A) AP BUILDING 26200 SECTION BID OPTION / AP EDIFICIO 26200 SEZIONE
OPZIONE OFFERTA
14092116 (S-308) AP BUILDING 26200 SECTION / AP EDIFICIO 26200 SEZIONE
14092117 (S-308A) AP BUILDING 26200 SECTION BID OPTION AP EDIFICIO 26200 SEZIONE
OPZIONE OFFERTA
14092118 (S-309) AP BUILDING 26200 SECTIONS / AP EDIFICIO 26200 SEZIONI
14092119 (S-309A) AP BUILDING 26200 SECTIONS BID OPTION / AP EDIFICIO 26200 SEZIONI
OPZIONE OFFERTA
14092198 (A-101) AP BUILDING 23400 GROUND FLOOR PLAN / AP EDIFICIO 23400 PIANTA
PIANO TERRA
14092210 (A-113) AP BUILDING 23200 GROUND FLOOR PLAN / AP EDIFICIO 23200 PIANTA
PIANO TERRA
14092216 (A-119) AP BUILDING 26200 GROUND FLOOR PLAN / AP EDIFICIO 26200 PIANTA
PIANO TERRA
14092332 (A-422) 3BR APARTMENT GROUND FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO PIANO TERRA PROSPETTO INTERNO
14092333 (A-423) 3BR APARTMENT GROUND FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO PIANO TERRA PROSPETTO INTERNO
14092334 (A-424) 3BR APARTMENT TYPICAL FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO PIANO TIPO PROSPETTO INTERNO
14092335 (A-425) 3BR APARTMENT TYPICAL FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO PIANO TIPO PROSPETTO INTERNO
14092336 (A-426) 3BR APARTMENT FIRST FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO PIANO PRIMO PROSPETTO INTERNO
14092337 (A-427) 3BR APARTMENT FIRST FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO PIANO PRIMO PROSPETTO INTERNO
14092338 (A-428) 3BR APARTMENT ABA GROUND FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO ABA PIANO TERRA PROSPETTO INTERNO
14092339 (A-429) 3BR APARTMENT ABA GROUND FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO ABA PIANO TERRA PROSPETTO INTERNO
14092340 (A-430) 3BR APARTMENT ABA TYPICAL FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO ABA PIANO TIPO PROSPETTO INTERNO
14092341 (A-431) 3BR APARTMENT ABA TYPICAL FLOOR INTERIOR ELEVATION / 3BR
APPARTAMENTO ABA PIANO TIPO PROSPETTO INTERNO
14092342 (A-432) 4BR APARTMENT TYPICAL FLOOR INTERIOR ELEVATION / 4BR
APPARTAMENTO PIANO TIPO PROSPETTO INTERNO
14092343 (A-433) 4BR APARTMENT TYPICAL FLOOR INTERIOR ELEVATION / 4BR
APPARTAMENTO PIANO TIPO PROSPETTO INTERNO
14092344 (A-434) 4BR APARTMENT ABA GROUND FLOOR INTERIOR ELEVATION / 4BR
APPARTAMENTO ABA PIANO TERRA PROSPETTO INTERNO
14092345 (A-435) 4BR APARTMENT ABA GROUND FLOOR INTERIOR ELEVATION / 4BR
APPARTAMENTO ABA PIANO TERRA PROSPETTO INTERNO
14092346 (A-436) 3BR TOWNHOUSE INTERIOR ELEVATIONS / 3BR TOWNHOUSE PROSPETTI
INTERNI
14092347 (A-437) 3BR TOWNHOUSE INTERIOR ELEVATIONS / 3BR TOWNHOUSE PROSPETTI
INTERNI
14092348 (A-438) 4BR TOWNHOUSE INTERIOR ELEVATIONS / 4BR TOWNHOUSE PROSPETTI
INTERNI
14092349 (A-439) 4BR TOWNHOUSE INTERIOR ELEVATIONS / 4BR TOWNHOUSE PROSPETTI
INTERNI
14092350 (A-440) 3BR CORNER TOWNHOUSE INTERIOR ELEVATIONS / 3BR CORNER
TOWNHOUSE PROSPETTI INTERNI
14092351 (A-441) 3BR CORNER TOWNHOUSE INTERIOR ELEVATIONS / 3BR CORNER
TOWNHOUSE PROSPETTI INTERNI
14092415 (A-569) INTERNAL DETAIL JOINERY / DETTAGLI FALEGNAMERIA INTERNA
14092416 (A-570) INTERNAL DETAIL JOINERY / DETTAGLI FALEGNAMERIA INTERNA
14092420 (A-574) INTERNAL DETAIL JOINERY / DETTAGLI FALEGNAMERIA INTERNA
14092421 (A-575) INTERNAL DETAIL JOINERY / DETTAGLI FALEGNAMERIA INTERNA
14092425 (A-579) INTERNAL DETAIL JOINERY / DETTAGLI FALEGNAMERIA INTERNA
14092426 (A-580) INTERNAL DETAIL JOINERY / DETTAGLI FALEGNAMERIA INTERNA
14092433 (A-605) FLOOR FINISHES TYPES SCHEDULE / ELENCO TIPOLOGIE FINITURE PER
PAVIMENTAZIONE
14092445 (A-617) AP BUILDING 23400 DOOR SCHEDULES / AP EDIFICIO 23400 ABACO TELAIO
PORTA
14092449 (A-621) AP BUILDING 23200 DOOR SCHEDULES / AP EDIFICIO 23200 ABACO TELAIO
PORTA
14092451 (A-623) AP BUILDING 26200 DOOR SCHEDULES / AP EDIFICIO 26200 ABACO TELAIO
PORTA
14092457 (A-629) PLUMBING FIXTURES SCHEDULE / ABACO APPARECCHI IDRICO
SANITARISANITARI
14092460 (I-101) 3BR APARTMENT GROUND FLOOR CEILING PLAN / 3BR APPARTAMENTO
PIANTA CONTROSOFFITTI PIANO TERRA
14092461 (I-102) 3BR APARTMENT TYPICAL FLOOR CEILING PLAN / 3BR APPARTAMENTO
PIANTA CONTROSOFFITTI PIANO TIPICO
14092462 (I-103) 3BR APARTMENT FIRST FLOOR CEILING PLAN / 3BR APPARTAMENTO
PIANTA CONTROSOFFITTI PIANO PRIMO
14092463 (I-104) 3BR APARTMENT ABA GROUND FLOOR CEILING PLAN / 3BR
APPARTAMENTO ABA PIANTA CONTROSOFFITTI PIANO TERRA
14092464 (I-105) 3BR APARTMENT ABA FLOOR CEILING PLAN / 3BR APPARTAMENTO ABA
PIANTA CONTROSOFFITTI
14092465 (I-106) 4BR APARTMENT TYPICAL FLOOR CEILING PLAN / 4BR APPARTAMENTO
PIANTA CONTROSOFFITTI PIANO TIPICO
14092466 (I-107) 4BR APARTMENT ABA FLOOR CEILING PLAN / 4BR APPARTAMENTO ABA
PIANTA CONTROSOFFITTI PIANO
14092467 (I-108) 3BR TH GROUND, FIRST AND SECOND FLOOR CEILING PLAN / 3BR TH
PIANTA CONTROSOFFITTI PIANO TERRA, PRIMO E 2°
14092468 (I-109) 4BR TH GROUND, FIRST AND SECOND FLOOR CEILING PLAN / 4BR TH
PIANTA CONTROSOFFITTI PIANO TERRA, PRIMO E 2°
14092469 (I-110) 3BR CORNER TH GROUND, FIRST AND SECOND CEILING PLAN / 3BR
CORNER TH PIANTA CONTROSOFFITTI PIANO TERRA, 1°,2°
14092471 (I-112) AP BUILDING 23400 GROUND FLOOR GARAGE CEILING PLAN / AP ED. 23400
PIANTA CONTROSOFFITTO GARAGE PIANO TERRA
14092477 (I-118) AP BUILDING 23200 GROUND FLOOR GARAGE CEILING PLAN / AP ED. 23200
PIANTA CONTROSOFFITTO GARAGE PIANO TERRA
14092480 (I-121) AP BUILDING 26200 GROUND FLOOR GARAGE CEILING PLAN / AP ED. 26200
PIANTA CONTROSOFFITTO GARAGE PIANO TERRA
14092485 (I-601) INTERIOR DESIGN FINISHES LEGEND / LEGENDA FINITURE DESIGN
INTERNO
14092486 (I-602) APARTMENT BUILDING ROOM FINISH SCHEDULE / APPARTAMENTO
EDIFICIO ABACO ARREDAMENTO LOCALI
14092488 (IN101) 3BR APARTMENT GROUND FLOOR FINISH PLAN / 3BR APPARTAMENTO
PIANTA FINITURE PIANO TERRA
14092489 (IN102) 3BR APARTMENT TYPICAL FLOOR FINISH PLAN / 3BR APPARTAMENTO
PIANTA FINITURE PIANO TIPICO
14092490 (IN103) 3BR APARTMENT FIRST FLOOR FINISH PLAN / 3BR APPARTAMENTO PIANTA
FINITURE PIANO PRIMO
14092493 (IN106) 4BR APARTMENT TYPICAL FLOOR FINISH PLAN / 4BR APPARTAMENTO
PIANTA FINITURE PIANO TIPICO
14092500 (IN113) 3BR TH GROUND, FIRST AND SECOND FLOOR FINISH PLAN / 3BR TH PIANTA
FINITURE PIANO TERRA, PRIMO E SECONDO
14092501 (IN114) 4BR TH GROUND, FIRST AND SECOND FLOOR FINISH PLAN / 4BR TH PIANTA
FINITURE PIANO TERRA, PRIMO E SECONDO
14092502 (IN115) 3BR CORNER TH GROUND, FIRST AND SECOND FLR FINISH PLAN / 3BR
CORNER TH PIANTA FINITURE PIANO TERRA, PRIMO E 2°
14092504 (IN117) AP BUILDING 23400 GARAGE FINISH PLAN / AP EDIFICIO 23400 PIANTA
FINITURE GARAGE
14092506 (IN119) AP BUILDING 23200 GARAGE FINISH PLAN / AP EDIFICIO 23200 PIANTA
FINITURE GARAGE
14092507 (IN120) AP BUILDING 26200 GARAGE FINISH PLAN / AP EDIFICIO 26200 PIANTA
FINITURE GARAGE
14092509 (IF401) 3BR APARTMENT GROUND FLOOR FURNITURE PLAN / 3BR APPARTAMENTO
PIANTA ARREDAMENTI PIANO TERRA
14092510 (IF402) 3BR APARTMENT TYPICAL FLOOR FURNITURE PLAN / 3BR APPARTAMENTO
PIANTA ARREDAMENTI PIANO TIPICO
14092511 (IF403) 3BR APARTMENT FIRST FLOOR FURNITURE PLAN / 3BR APPARTAMENTO
PIANTA ARREDAMENTI PIANO PRIMO
14092512 (IF404) 3BR APARTMENT ABA GROUND FLOOR FURNITURE PLAN / 3BR
APPARTAMENTO ABA PIANTA ARREDAMENTI PIANO TERRA
14092513 (IF405) 3BR APARTMENT ABA FLOOR FURNITURE PLAN / 3BR APPARTAMENTO
ABA PIANTA ARREDAMENTI
14092514 (IF406) 4BR APARTMENT TYPICAL FLOOR FURNITURE PLAN / 4BR APPARTAMENTO
PIANTA ARREDAMENTI PIANO TIPICO
14092515 (IF407) 4BR APARTMENT ABA FLOOR FURNITURE PLAN / 4BR APPARTAMENTO
ABA PIANTA ARREDAMENTI
14092516 (IF408) 3BR TH GROUND, FIRST AND SECOND FLOOR FURNITURE PLAN / 3BR TH
PIANTA ARREDAMENTI PIANO TERRA, PRIMO E SECONDO
14092517 (IF409) 4BR TH GROUND, FIRST AND SECOND FLOOR FURNITURE PLAN / 4BR TH
PIANTA ARREDAMENTI PIANO TERRA, PRIMO E SECONDO
14092518 (IF410) 3BR CORNER TH GROUND, FIRST AND SECOND FURNITURE PLAN / 3BR
CORNER TH PIANO ARREDO PIANO TERRA, PRIMO E 2°
14092520 (IS102) AP BUILDING 23400 GARAGE SIGNAGE PLAN / AP EDIFICIO 23400 GARAGE
PIANTA SEGNALETICA
14092525 (IS107) AP BUILDING 23200 GARAGE SIGNAGE PLAN / AP EDIFICIO 23200 GARAGE
PIANTA SEGNALETICA
14092527 (IS109) AP BUILDING 26200 GARAGE SIGNAGE PLAN / AP EDIFICIO 26200 GARAGE
PIANTA SEGNALETICA
14092626 (PW102) AP BUILDING 23400 FIRST FLOOR WASTE PLAN / AP EDIFICIO 23400 PIANTA
SCARICHI PIANO PRIMA
14092627 (PW103) AP BUILDING 23400 SECOND FLOOR WASTE PLAN / AP EDIFICIO 23400
PIANTA SCARICHI PIANO SECONDO
14092628 (PW104) AP BUILDING 23400 THIRD FLOOR WASTE PLAN / AP EDIFICIO 23400 PIANTA
SCARICHI PIANO TERZO
14092630 (PW107) AP BUILDING 23500 GROUND FLOOR WASTE PLAN / AP EDIFICIO 23500
PIANTA SCARICHI PIANO TERRA
14092631 (PW108) AP BUILDING 23500 FIRST FLOOR WASTE PLAN / AP EDIFICIO 23500 PIANTA
SCARICHI PIANO PRIMA
14092632 (PW109) AP BUILDING 23500 SECOND FLOOR WASTE PLAN / AP EDIFICIO 23500
PIANTA SCARICHI PIANO SECONDO
14092633 (PW110) AP BUILDING 23500 THIRD FLOOR WASTE PLAN / AP EDIFICIO 23500 PIANTA
SCARICHI PIANO TERZO
14092635 (PW112) AP BUILDING 23200 GROUND FLOOR WASTE PLAN / AP EDIFICIO 23200
PIANTA SCARICHI PIANO TERRA
14092636 (PW113) AP BUILDING 23200 FIRST FLOOR WASTE PLAN / AP EDIFICIO 23200 PIANTA
SCARICHI PIANO PRIMA
14092637 (PW114) AP BUILDING 23200 SECOND FLOOR WASTE PLAN / AP EDIFICIO 23200
PIANTA SCARICHI PIANO SECONDO
14092638 (PW115) AP BUILDING 23200 THIRD FLOOR WASTE PLAN / AP EDIFICIO 23200 PIANTA
SCARICHI PIANO TERZO
14092640 (PW118) AP BUILDING 26200 GROUND FLOOR WASTE PLAN / AP EDIFICIO 26200
PIANTA SCARICHI PIANO TERRA
14092641 (PW119) AP BUILDING 26200 FIRST FLOOR WASTE PLAN / AP EDIFICIO 26200 PIANTA
SCARICHI PIANO PRIMA
14092642 (PW120) AP BUILDING 26200 SECOND FLOOR WASTE PLAN / AP EDIFICIO 26200
PIANTA SCARICHI PIANO SECONDO
14092643 (PW121) AP BUILDING 26200 THIRD FLOOR WASTE PLAN / AP EDIFICIO 26200 PIANTA
SCARICHI PIANO TERZO
14092653 (P-401) 3BR APARTMENT GROUND FLOOR PLUMBING PLAN / 3BR APPARTAMENTO
IMPIANTO IDRICO PIANO TERRA
14092654 (P-402) 3BR APARTMENT TYPICAL FLOOR PLUMBING PLAN / 3BR APPARTAMENTO
IMPIANTO IDRICO PIANO TIPICO
14092655 (P-403) 3BR APARTMENT ABA GROUND FLOOR PLUMBING PLAN / 3BR
APPARTAMENTO ABA IMPIANTO IDRICO PIANO TERRA
14092656 (P-404) 3BR APARTMENT ABA FIRST FLOOR PLUMBING PLAN / 3BR
APPARTAMENTO ABA IMPIANTO IDRICO PIANO PRIMO
14092657 (P-405) 4BR APARTMENT TYPICAL FLOOR PLUMBING PLAN / 4BR APPARTAMENTO
IMPIANTO IDRICO PIANO TIPICO
14092664 (PL402) 3BR TH SECOND FLOOR SUPPLY PLAN / 3BR TH PIANTA ADDUZIONE PIANO
SECONDO
14092666 (PL404) 4BR TH SECOND FLOOR SUPPLY PLAN / 4BR TH PIANTA ADDUZIONE PIANO
SECONDO
14092668 (PL406) 3BR CORNER TH SECOND FLOOR SUPPLY PLAN / 3BR CORNER TH PIANTA
ADDUZIONE PIANO SECONDO
14092670 (PW402) 3BR TH SECOND FLOOR AND ROOF WASTE PLAN / 3BR TH PIANTA
SCARICHI PIANO 2° E COPERTURA
14092672 (PW404) 4BR TH SECOND FLOOR AND ROOF WASTE PLAN / 4BR TH PIANTA
SCARICHI PIANO 2° E COPERTURA
14092674 (PW406) 3BR CORNER TH SECOND FLOOR AND ROOF WASTE PLAN / 3BR CORNER TH
PIANTA SCARICHI PIANO 2° E COPERTURA
14092683 (PL901) 3BR APARTMENT SUPPLY ISOMETRIC DIAGRAM / 3BR APPARTAMENTO
DIAGRAMMA ISOMETRICO MANDATA
14092684 (PL902) 4BR APARTMENT SUPPLY ISOMETRIC DIAGRAM / 4BR APPARTAMENTO
DIAGRAMMA ISOMETRICO MANDATA
14092685 (PL903) 3BR AP ABA GROUND FLOOR SUPPLY ISOMETRIC DIAGRAM / 3BR AP ABA
DIAGRAMMA ISOMETRICO MANDATA PIANO TERRA
14092686 (PL904) 3BR AP ABA FLOOR SUPPLY ISOMETRIC DIAGRAM / 3BR AP ABA
DIAGRAMMA ISOMETRICO MANDATA DI PIANO
14092687 (PL905) 4BR AP TYPICAL FLOOR SUPPLY ISOMETRIC DIAGRAM / 4BR AP ABA
DIAGRAMMA ISOMETRICO MANDATA PIANO TIPO
14092688 (PL906) 4BR AP ABA FLOOR SUPPLY ISOMETRIC DIAGRAM / 4BR AP ABA
DIAGRAMMA ISOMETRICO MANDATA DI PIANO
14092693 (PL911) 3BR TOWNHOUSE SUPPLY ISOMETRIC DIAGRAM / 3BR TOWNHOUSE
DIAGRAMMA ISOMETRICO MANDATA
14092694 (PL912) 4BR TOWNHOUSE SUPPLY ISOMETRIC DIAGRAM / 4BR TOWNHOUSE
DIAGRAMMA ISOMETRICO MANDATA
14092695 (PL913) 3BR CORNER TOWNHOUSE SUPPLY ISOMETRIC DIAGRAM / 3BR CORNER
TOWNHOUSE DIAGRAMMA ISOMETRICO MANDATA
14092696 (PW901) AP BUILDING 23400 WASTE RISER DIAGRAM / AP EDIFICIO 23400
DIAGRAMMA COLONNA MONTANTE SCARICO
14092697 (PW902) AP BUILDING 23400 WASTE RISER DIAGRAM / AP EDIFICIO 23400
DIAGRAMMA COLONNA MONTANTE SCARICO
14092698 (PW903) AP BUILDING 23500 WASTE RISER DIAGRAM / AP EDIFICIO 23500
DIAGRAMMA COLONNA MONTANTE SCARICO
14092699 (PW904) AP BUILDING 23500 WASTE RISER DIAGRAM / AP EDIFICIO 23500
DIAGRAMMA COLONNA MONTANTE SCARICO
14092700 (PW905) AP BUILDING 23200 WASTE RISER DIAGRAM / AP EDIFICIO 23200
DIAGRAMMA COLONNA MONTANTE SCARICO
14092701 (PW906) AP BUILDING 23200 WASTE RISER DIAGRAM / AP EDIFICIO 23200
DIAGRAMMA COLONNA MONTANTE SCARICO
14092702 (PW907) AP BUILDING 26200 WASTE RISER DIAGRAM / AP EDIFICIO 26200
DIAGRAMMA COLONNA MONTANTE SCARICO
14092703 (PW908) AP BUILDING 26200 WASTE RISER DIAGRAM / AP EDIFICIO 26200
DIAGRAMMA COLONNA MONTANTE SCARICO
14092704 (PW909) 3BR TOWNHOUSE WASTE RISER DIAGRAM / AP EDIFICIO 26200
DIAGRAMMA COLONNA MONTANTE SCARICO
14092705 (PW910) 4BR TOWNHOUSE WASTE RISER DIAGRAM / 3BR TOWNHOUSE
DIAGRAMMA COLONNA MONTANTE SCARICO
14092706 (PW911) 3BR CORNER TOWNHOUSE WASTE RISER DIAGRAM / 3BR CORNER TH
DIAGRAMMA COLONNA MONTANTE SCARICO
14092748 (MH401) 3BR APARTMENT GROUND FLOOR MECHANICAL PLAN / 3BR
APPARTAMENTO IMPIANTI MECCANICI PIANO TERRA
14092749 (MH402) 3BR APARTMENT TYPICAL FLOOR MECHANICAL PLAN / 3BR
APPARTAMENTO IMPIANTI MECCANICI PIANO TIPICO
14092750 (MH403) 3BR AP 23500 GROUND AND TYPICAL FLOOR MECHANICAL PLAN / 3BR AP
23500 IMPIANTI MECCANICI PIANO TERRA E TIPICO
14092751 (MH404) 3BR APARTMENT ABA GROUND FLOOR MECHANICAL PLAN / 3BR
APPARTAMENTO ABA IMPIANTI MECCANICI PIANO TERRA
14092752 (MH405) 3BR APARTMENT ABA TYPICAL FLOOR MECHANICAL PLAN / 3BR
APPARTAMENTO ABA IMPIANTI MECCANICI PIANO TIPICO
14092753 (MH406) 4BR APARTMENT TYPICAL FLOOR MECHANICAL PLAN / 4BR
APPARTAMENTO IMPIANTI MECCANICI PIANO TIPICO
14092768 (MH421) 4BR TH SECOND FLOOR AND ROOF MECHANICAL PLAN / 4BR TH IMPIANTI
MECCANICI PIANO SECONDO E COPERTURA
14092770 (MH423) 3BR CORNER TH SECOND FLOOR AND ROOF MECHANICAL PLAN / 3BR
CORNER TH IMPIANTI MECCANICI PIANO 2° E COPERTURA
14092798 (E-003) ELECTRICAL GENERAL NOTES, LEGENDS AND SYMBOLS / NOTE GENERALI,
LEGENDE E SIMBOLI ELETTRICI
14092835 (EL101) AP BUILDING 23400 GROUND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE AP EDIFICIO 23400 PIANO TERRA
14092840 (EL106) AP BUILDING 23500 GROUND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE AP EDIFICIO 23500 PIANO TERRA
14092857 (EP101) AP BUILDING 23400 GROUND FLOOR POWER PLAN / PIANTA
ALIMENTAZIONE AP EDIFICIO 23400 PIANO TERRA
14092909 (EL401) 3BR APARTMENT GROUND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 3BR APPARTAMENTO PIANO TERRA
14092910 (EL402) 3BR APARTMENT TYPICAL FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 3BR APPARTAMENTO PIANO TIPICO
14092911 (EL403) 3BR APARTMENT ABA GROUND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 3BR APPARTAMENTO ABA PIANO TERRA
14092912 (EL404) 3BR APARTMENT ABA FLOOR LIGHTING PLAN / PIANTA ILLUMINAZIONE
3BR APPARTAMENTO ABA PIANO
14092913 (EL405) 4BR APARTMENT TYPICAL FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 4BR APPARTAMENTO PIANO TIPICO
14092914 (EL406) 4BR APARTMENT ABA FLOOR LIGHTING PLAN / PIANTA ILLUMINAZIONE
4BR APPARTAMENTO ABA PIANO
14092915 (EL407) 3BR TH GROUND, FIRST AND SECOND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 3BR TH PIANO TERRA, PRIMO E 2°
14092916 (EL408) 4BR TH GROUND, FIRST AND SECOND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 4BR TH PIANO TERRA, PRIMO E 2°
14092917 (EL409) 3BR CORNER TH GROUND AND FIRST FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 3BR CORNER TH PIANO TERRA E PRIMO
14092918 (EL410) 3BR CORNER TH SECOND FLOOR LIGHTING PLAN / PIANTA
ILLUMINAZIONE 3BR CORNER TH PIANO SECONDO
14092919 (EP401) 3BR APARTMENT GROUND FLOOR POWER PLAN / PIANTA ALIMENTAZIONE
3BR APPARTAMENTO PIANO TERRA
14092920 (EP402) 3BR APARTMENT TYPICAL FLOOR POWER PLAN / PIANTA ALIMENTAZIONE
3BR APPARTAMENTO PIANO TIPICO
14092921 (EP403) 3BR APARTMENT ABA GROUND FLOOR POWER PLAN / PIANTA
ALIMENTAZIONE 3BR APPARTAMENTO ABA PIANO TERRA
14092922 (EP404) 3BR APARTMENT ABA FLOOR POWER PLAN / PIANTA ALIMENTAZIONE 3BR
APPARTAMENTO ABA PIANO
14092923 (EP405) 4BR APARTMENT TYPICAL FLOOR POWER PLAN / PIANTA ALIMENTAZIONE
4BR APPARTAMENTO PIANO TIPICO
14092924 (EP406) 4BR APARTMENT ABA FLOOR POWER PLAN / PIANTA ALIMENTAZIONE 4BR
APPARTAMENTO ABA PIANO
14092929 (EP411) 3BR TH GROUND, FIRST AND SECOND FLOOR POWER PLAN / PIANTA
ALIMENTAZIONE 3BR TH PIANO TERRA, PRIMO E 2°
14092930 (EP412) 4BR TH GROUND, FIRST AND SECOND FLOOR POWER PLAN / PIANTA
ALIMENTAZIONE 4BR TH PIANO TERRA, PRIMO E 2°
14092931 (EP413) 3BR CORNER TH GROUND AND FIRST FLOOR POWER PLAN / PIANTA
ALIMENTAZIONE 3BR CORNER TH PIANO TERRA E PRIMO
14092932 (EP414) 3BR CORNER TH SECOND FLOOR POWER PLAN / PIANTA ALIMENTAZIONE
3BR CORNER TH PIANO E SECONDO
The following drawing is revised as follows:
14092395 (A-540) ROLLER BLIND DETAIL BID OPTION / DETTAGLIO TENDA AVVOLGIBILE
OPZIONE OFFERTA
Revise Sheet Title From:
“ ROLLER BLIND DETAIL BID OPTION / DETTAGLIO TENDA AVVOLGIBILE OPZIONE OFFERTA”
To:
“EXTERIOR SHUTTERS BID OPTION / PERSIANE ESTERNE OPZIONE OFFERTA”
5. Provide Attachments:
• Attachment P: Revised 1632468 Specification Amendment 0006
• Attachment Q: Revised 1632468 Drawings Amendment 0006
SECTION 00 45 00 - REPRESENTATIONS AND CERTIFICATIONS
The following have been added by reference:
52.209-13 Violation of Arms Control Treaties or Agreements --
Certification
DEC 2021
52.215-1 Instructions to Offerors--Competitive Acquisition DEC 2021 52.222-23 Notice of Requirement for Affirmative Action to Ensure
Equal Employment Opportunity for Construction
FEB 1999
52.222-56 Certification Regarding Trafficking in Persons Compliance Plan.
OCT 2020
252.203-7005 Representation Relating to Compensation of Former DoD Officials
NOV 2011
252.204-7019 Notice of NIST SP 800-171 DoD Assessment Requirements NOV 2020 252.215-7008 Only One Offer JUL 2019 252.215-7013 Supplies and Services Provided by Nontraditional Defense
Contractors.
JAN 2018
252.236-7006 Cost Limitation JAN 1997
52.204-8 ANNUAL REPRESENTATIONS AND CERTIFICATIONS (NOV 2021)
(a)(1) The North American Industry Classification System (NAICS) code for this acquisition is 236116.
(2) The small business size standard is $39,500,000.
(3) The small business size standard for a concern that submits an offer, other than on a construction or service acquisition, but proposes to furnish an end item that it did not itself manufacture, process, or produce is 500 employees if the acquisition--
(i) Is set aside for small business and has a value above the simplified acquisition threshold;
(ii) Uses the HUBZone price evaluation preference regardless of dollar value, unless the offeror waives the price evaluation preference; or
(iii) Is an 8(a), HUBZone, service-disabled veteran-owned, economically disadvantaged women-owned, or women-owned small business set-aside or sole-source award regardless of dollar value.
(b)(1) If the provision at 52.204-7, System for Award Management, is included in this solicitation, paragraph (d) of this provision applies.
(2) If the provision at 52.204-7, System for Award Management, is not included in this solicitation, and the Offeror has an active registration in the System for Award Management (SAM), the Offeror may choose to use paragraph (d) of this provision instead of completing the corresponding individual representations and certifications in the solicitation. The Offeror shall indicate which option applies by checking one of the following boxes:
( ) Paragraph (d) applies.
( ) Paragraph (d) does not apply and the offeror has completed the individual representations and certifications in the solicitation.
(c) (1) The following representations or certifications in SAM are applicable to this solicitation as indicated:
(i) 52.203-2, Certificate of Independent Price Determination. This provision applies to solicitations when a firm-fixed-price contract or fixed-price contract with economic price adjustment is contemplated, unless—
(A) The acquisition is to be made under the simplified acquisition procedures in Part 13;
(B) The solicitation is a request for technical proposals under two-step sealed bidding procedures; or
(C) The solicitation is for utility services for which rates are set by law or regulation.
(ii) 52.203-11, Certification and Disclosure Regarding Payments to Influence Certain Federal Transactions. This provision applies to solicitations expected to exceed $150,000.
(iii) 52.203-18, Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements--Representation. This provision applies to all solicitations.
(iv) 52.204-3, Taxpayer Identification. This provision applies to solicitations that do not include the provision at 52.204-7, System for Award Management.
(v) 52.204-5, Women-Owned Business (Other Than Small Business). This provision applies to solicitations that—
(A) Are not set aside for small business concerns;
(B) Exceed the simplified acquisition threshold; and
(C)…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .