This document provides details on a federal solicitation for construction services. The solicitation number is N62470-21-R-0015 and seeks proposals for Phase 2 of the Family Housing Villaggio project at Vicenza, Italy. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Proposals are due on the date specified in the attached solicitation for the construction of additional family housing units at the Villaggio housing complex in Vicenza, Italy. The solicitation includes relevant details on the scope of work, specifications, response requirements, and evaluation criteria.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_21JUN2022.pdf PDF
N6247021R0015 Amend 0015.pdf PDF
N6247021R0015 Amend 0014.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247021R0015 Amend 0013.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_10JUN2022.pdf PDF
N6247021R0015 Amend 0012.pdf PDF
Attachment W - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment X - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247021R0015 Amend 0011.pdf PDF
Attachment V - Revised 1632468 Drawings Amendment 0010.pdf PDF
Attachment U - Revised 1632468 Specification Amendment 0010.pdf PDF
N6247021R0015 Amend 0010.pdf PDF
Attachment T - 1632846 Foundation and Misc Revisions Drawings 02of 02.pdf PDF
Attachment R - 1632846 Foundation and Misc Revisions Specifications.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247021R0015 Amend 0009.pdf PDF
Attachment J - PSC Italian Revised March 24 2022.pdf PDF
Attachment S - 1632846 Foundation and Misc Revisions Drawings 01 of 02.pdf PDF
N6247021R0015 Amend 0008.pdf PDF
N6247021R0015 Amend 0007.pdf PDF
Attachment Q Revised 1632468 Drawings Amendment 0006.pdf PDF
N6247021R0015 Amend 0006.pdf PDF
Attachment P Revised 1632468 Specification Amendment 0006.pdf PDF
N6247021R0015 Amend 0005.pdf PDF
Attachment M Pre-proposal Conference Attendee Log.pdf PDF
Attachment N Revised 1632846 Specifications.pdf PDF
Attachment O Revised 1632846 Drawings.pdf PDF
N6247021R0015 Amend 0004.pdf PDF
N6247021R0015 Amend 0003.pdf PDF
N6247021R0015 Amend 0002.pdf PDF
N6247021R0015 Amend 0001.pdf PDF
Attachment I - 1632846dwg20of24.pdf PDF
Attachment I - 1632846dwg09of24.pdf PDF
Attachment I - 1632846dwg04of24.pdf PDF
Attachment I - 1632846dwg10of24.pdf PDF
Attachment I - 1632846dwg14of24.pdf PDF
Attachment I - 1632846dwg11of24.pdf PDF
Attachment I - 1632846dwg08of24.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment I - 1632846dwg24of24.pdf PDF
Attachment H - Specifications.pdf PDF
Attachment I - 1632846dwg02of24.pdf PDF
Attachment I - 1632846dwg03of24.pdf PDF
Attachment I - 1632846dwg18of24.pdf PDF
Attachment I - 1632846dwg12of24.pdf PDF
Attachment L - DWG Index.pdf PDF
Attachment I - 1632846dwg23of24.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
N6247021R0015.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

E

3.15C3 S-535

A1 S-532

C3 S-533

B1 S-533

B1 S-533

C2 S-535

C2 S-535

C2 S-532

C3 S-535

A2 S-530

D2 S-531

A3 S-535

A3 S-535

3.123.123.12 A3

S-534

B1 S-534

3.51

3.66

3.51

3.51

3.51

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3.09

3.70

3.70

3.70

3.51

3.08

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.60

3.66

3.51

3.51

3.51

3.51

3.60

16.317

TOW 18.600

TOW 18.100

13.600

11.900

10.200

8.500

6.800

5.100

3.400

1.700

16.317

8.03

3.01 3.01

-0.200

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:2 :4

IDB MHCE

A P

B U

IL

D

IN

G

S

E C

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

E

S-301

14092102

C E

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A A .r vt

SCALE 1 : 100 (S-101)

A1

AP BUILDING 23400 SECTIONS /

AP EDIFICIO 23400 SEZIONE

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO

ARMATO 150mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532

8.03 1250x1250mm SMOKE HATCH OPENING. REFER TO DETAIL A1 ON SHEET

S-529 / APERTURA SPORTELLO FUMI 1250x1250mm. FARE RIFERIMENTO AL

DETTAGLIO A1 DELL'ELABORATO S-529

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION

GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID

FOR 23300 /

GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE

FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO

VALIDI ANCHE PER IL 23300

H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE

DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /

VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA

DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI

SLAB AND FRAMING NOTES /

NOTE SULLA SOLETTA E

SULL'INTELAIATURA

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

E

3.51

3.51

3.51

3.51 3.51

3.51

3.51

3.51

13.600

11.900

10.200

8.500

5.100

6.800

3.400

1.700

3.08

3.08

3.08

3.08

3.08

3.08

3.15C3 S-535

A1 S-532

C3 S-533

B1 S-533

B1 S-533

C2 S-535

C2 S-535

C2 S-532

C3 S-535

3.60 3.60

3.51 3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.08

3.70

3.70

3.70

3.66 3.66

A2 S-530

D2 S-531

A3 S-535

A3 S-535

3.09

3.123.123.12 A3

S-534

B1 S-534

TOW 18.600

TOW 18.100

16.317 16.317

3.51

8.03

3.01 3.01

3.51 3.51

-0.200

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:2 :4

IDB MHCE

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

E O

P

ZI

O N

E O

FF

E

R

TA

S-301A

14092103

C E

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A A .r vt

SCALE 1 : 100

A1

AP BUILDING 23400 SECTION /

AP EDIFICIO 23400 SEZIONE

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO

ARMATO 150mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532

8.03 1250x1250mm SMOKE HATCH OPENING. REFER TO DETAIL A1 ON SHEET

S-529 / APERTURA SPORTELLO FUMI 1250x1250mm. FARE RIFERIMENTO AL

DETTAGLIO A1 DELL'ELABORATO S-529

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION

GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID

FOR 23300 /

GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE

FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO

VALIDI ANCHE PER IL 23300

H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE

DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /

VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA

DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

EA2

S-220A

3.15 C3

S-535

A2 S-535

B1 S-533

B1 S-533

A2 S-530 A2

S-530

C4 S-531

B1 S-533

A2 S-530

C2 S-535

C2 S-535

A3 S-534

B1 S-534

-1.500

3.513.51 3.51

3.51

3.513.51

3.51

3.51

3.51

3.08

3.08

3.08

3.08

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3.60 3.60

3.51

3.51

3.51

3.51

3.51

3.51

3.15

3.09

3.08

3.51

3.12

8.11

3.12

3.01 3.01

3.51 3.51

TOW 14.835

TOW 18.100 TOW 18.100

TOW 15.640

TOW 14.83514.750

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:2 :5

IDB MHCE

A P

B U

IL

D

IN

G

S

E C

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

E

S-302

14092104

C E

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A A .r vt

SCALE 1 : 100 (S-101)

A1

AP BUILDING 23400 SECTIONS /

AP EDIFICIO 23400 SEZIONE

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA

COLATA

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION

GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID

FOR 23300 /

GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE

FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO

VALIDI ANCHE PER IL 23300

H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE

DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /

VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA

DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

E

3.513.51 3.51

3.51

3.513.51

3.51

3.51

3.51

3.08

3.08

3.08

3.08

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3.15

C3 S-535

A2 S-535

B1 S-533

B1 S-533

A2 S-530 A2

S-530

C4 S-531

B1 S-533

A2 S-530

C2 S-535

C2 S-535

3.60 3.60

3.51

3.51

3.51

3.51

3.51

3.51

3.15

3.09

3.08

3.51

3.12

8.11

3.12 A3

S-534 B1

S-534

-1.500

14.750TOW 14.835

TOW 18.100 TOW 18.100

TOW 15.640

TOW 14.835

3.01 3.01 -0.200

3.51 3.51

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:2 :5

IDB MHCE

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

E O

P

ZI

O N

E O

FF

E

R

TA

S-302A

14092105

C E

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A A .r vt

SCALE 1 : 100

A1

AP BUILDING 23400 SECTION /

AP EDIFICIO 23400 SEZIONE

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA

COLATA

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION

GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID

FOR 23300 /

GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE

FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO

VALIDI ANCHE PER IL 23300

H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE

DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /

VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA

DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI

SLAB AND FRAMING NOTES /

235 14

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

A1 S-214A

A1 S-213A

20850

2160826582652160

3.15

A2 S-535

A2 S-530

B1 S-533

A1 S-533

C2 S-535

A1 S-530 A1

S-530

A2 S-531

A3 S-533A3

S-533

14.419 5% 5%

3.01

3.08

3.08

3.08

3.51 3.51

3.15

3.60

3.51

3.543.54

3.51

3.15

3.51

3.51

3.51

3.51

3.32 3.333.33

3.01

2.860

3.08

5%

3.51

2.8605%

3.08

TOW 14.540 TOW 14.540

SE_FOUNDATION TOC

-1500.000

12 161413 15

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

A1 S-212A

A1 S-211A

A1 S-218A

2160 8265 8265 2160

20850

3.15

A2 S-535

B1 S-533

A1 S-533

B1 S-533

C2 S-535

C2 S-535

C3 S-532

C3 S-527

A3 S-535

14.419

-1.500

5% 5%

3.51 3.51

3.51

3.51

3.08

3.08

3.08

3.15

3.66

3.51

3.51

3.51

3.60 3.51

3.51

3.513.54

3.60

3.31 3.31

3.01

3.233.233.23

TOW 15.640

16.317

15.320

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:2 :5

IDB MHCE

A P

B U

IL

D

IN

G

S

E C

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

I

S-303

14092106

C E

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A A .r vt

SCALE 1 : 100 (S-101)

C1

AP BUILDING 23400 CROSS SECTION 1 /

APPARTAMENTO 23400 SEZIONE TRASVERSALE 1

SCALE 1 : 100 (S-101)

A1

AP BUILDING 23400 CROSS SECTION 2 /

APPARTAMENTO 23400 SEZIONE TRASVERSALE 2

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE

DETAIL C3 ON SHEET S-528 / PILASTRO IN CALCESTRUZZO ARMATO C2

SOLO AL PIANO TERRA. VEDI DETTAGLIO C3 SUL FOGLIO S-528

3.31 REINFORCED CONCRETE BEAM 300x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 300x700mm

SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531

3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm

SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531

3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION

GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID

FOR 23300 /

GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE

FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO

VALIDI ANCHE PER IL 23300

H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE

DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /

VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA

DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI

SLAB AND FRAMING NOTES /

235 14

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

20850

2160826582652160

3.08

3.08

3.08

3.51 3.51

3.15

A2 S-535

A2 S-530

B1 S-533

A1 S-533

C2 S-535

3.60

3.51

3.543.54

3.51

3.15

3.51

3.51

3.51

3.51

3.32 3.333.33

A1 S-530

A1 S-530

A2 S-531

A3 S-533A3

S-533

TOW 14.540 TOW 14.54014.419

2.8602.860 5% 5%

5% 5%

3.01

3.08 3.08

SE_FOUNDATION TOC

-1500.000

12 161413 15

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

2160 8265 8265 2160

20850

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.15

A2 S-535

B1 S-533

A1 S-533

B1 S-533

C2 S-535

C2 S-535

3.66

3.51

3.51

3.51

3.60

3.51

3.51

3.51 3.54

3.23

3.51 3.51

3.60

C3 S-532

C3 S-527

A3 S-535

TOW 15.640

16.317

3.31 3.31

14.419

-1.500

30%

5% 5%

3.01 3.01

15.320

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:2 :5

IDB MHCE

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

I O P

ZI

O

N E

O

FF

E R

TA

S-303A

14092107

C E

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A A .r vt

SCALE 1 : 100

C1

AP BUILDING 23400 CROSS SECTION 1 /

AP EDIFICIO 23400 SEZIONE TRASVERSALE 1

SCALE 1 : 100

A1

AP BUILDING 23400 CROSS SECTION 2 /

AP EDIFICIO 23400 SEZIONE TRASVERSALE 2

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE

DETAIL C3 ON SHEET S-528 / PILASTRO IN CALCESTRUZZO ARMATO C2

SOLO AL PIANO TERRA. VEDI DETTAGLIO C3 SUL FOGLIO S-528

3.31 REINFORCED CONCRETE BEAM 300x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 300x700mm

SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531

3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm

SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531

3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION

GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID

FOR 23300 /

GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE

FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO

VALIDI ANCHE PER IL 23300

H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE

DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /

VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA

DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

ABG CDE

3.08

3.08

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3350 450 3450 980 2160

3.70

3.15

3.08

3.01

B1 S-533

B2 S-532

B1 S-532

B1 S-533

C3 S-535

A1 S-532

A2 S-530

A2 S-535

C3 S-531

B1 S-533

B1 S-533

B1 S-533

B2 S-532

B2 S-532

B2 S-532 B3

S-531

3.51

3.60

3.12

17.543

3.09

B1 S-532

3.08

3.08

5%

TOW 18.200

TOW 19.450

TOW 2.646

TOW 15.640

-1.500

14.157

10.140

6.740

3.340

-0.200

1.700

5.100

8.500

11.900

13.600

10.200

6.800

3.400

17.216

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :4

IDB MHVPP

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

A P

E D

IF

IC

IO

S E

ZI

O

N E

S-304

14092108

V P P

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A .r vt

SCALE 1 : 100

A1

AP BUILDING 23500 SECTION /

AP EDIFICIO 23500 SEZIONE

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

ABG CDE

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3350 450 3450 980 2160

3.70

3.15

3.08

3.01

B1 S-533

B2 S-532

B1 S-532

B1 S-533

C3 S-535

A1 S-532

A2 S-530

A2 S-535

C3 S-531

B1 S-533

B1 S-533

B1 S-533

B2 S-532

B2 S-532

B2 S-532 B3

S-531

3.51

3.51 3.51

3.60

3.12

14.152

3.51

TOW 15.640

TOW 19.450

3.09

B1 S-532

3.08

3.08

5%

TOW 18.200

2.646

3.400

6.800

10.200

13.600

10.140

6.740

3.340

-0.200

1.700

5.100

8.500

11.900

17.216

-1.500

3.61 3.61

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :4

IDB MHVPP

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

E O

P

ZI

O N

E O

FF

E

R

TA

S-304A

14092109

V P P

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A .r vt

SCALE 1 : 100

A1

AP BUILDING 23500 SECTION /

AP EDIFICIO 23500 SEZIONE

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN

PREDALLES 250mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

ABG CDE

3350 450 3450 980 2160

3.08

3.08

3.08

3.08

3.08

3.08

3.15

3.01

B1 S-533

C3 S-535

A2 S-530

A2 S-530

A3 S-535

A2 S-535

A2 S-535

C3 S-531

3.60

3.09

3.61

B1 S-533

B1 S-533

A2 S-535

3.61 14.279

-0.200 -0.200

-1.500

3.51

3.51

3.51

3.51

5%

16.340 30%

10.140

6.740

3.340

15.292

TOW 15.640 TOW 15.640

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.15

3.01

3.51 3.51

3.66

3.60

3.51

3.09

3.51 3.61

3.61

3.51

3.51

3.51

3.51

3.51

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

1 7 11 12 26730

16950 6870 2910

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.15

A2 S-530

B1 S-533

B1 S-533

B3 S-531 C3

S-531

B1 S-533

A2 S-530

B1 S-533

C3 S-531

A2 S-535

A2 S-535

A2 S-535

3.60

3.093.09

3.08

3.08

3.08

B2 S-530

-1.500-1.500

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

13.540

14.750

10.140

6.740

3.340

-0.200

14.107

17.342

TOW 15.500

TOW 18.200

TOW 19.450

3.61

3.08

3.08

TOW 2.646

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51 3.51

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :4

IDB MHVPP

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

A P

E D

IF

IC

IO

S E

ZI

O

N I

S-305

14092110

V P P

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A .r vt

SCALE 1 : 100

C1

AP BUILDING 23500 SECTION - 01 /

AP EDIFICIO 23500 SEZIONE - 01

SCALE 1 : 100

A1

AP BUILDING 23500 SECTION - 02 /

AP EDIFICIO 23500 SEZIONE - 02

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN

PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO

ARMATO 150mm

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

ABG CDE

3350 450 3450 980 2160

3.08

3.08

3.08

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.15

3.01

B1 S-533

C3 S-535

A2 S-530

A2 S-530

A3 S-535

A2 S-535

A2 S-535

C3 S-531

3.51 3.51

3.66

3.60

3.51

14.279

3.09

3.51

-0.200

3.61

B1 S-533

B1 S-533

A2 S-535

3.61

TOW 15.640

TOW 18.200

18.200

TOW 15.640

-1.500 -1.500

15.500

14.750

3.51

3.51

3.51

3.51

3.51

3.51

3.51

30% 16.340

5%

10.140

6.740

3.340

15.292

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

1 7 11 12 26730

16950 6870 2910

3.51

3.51

3.51

3.51 3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.15

A2 S-530

B1 S-533

B1 S-533

B3 S-531 C3

S-531

B1 S-533

A2 S-530

B1 S-533

C3 S-531

A2 S-535

A2 S-535

A2 S-535

3.60

17.342

3.093.09

3.08

3.08

3.08

TOW 15.500

TOW 19.450

TOW 2.646

-1.500

A2 S-530

TOW 18.200

-1.500

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

10.140

6.740

3.340

-0.200

14.107 13.540

14.750

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :5

IDB MHVPP

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

I O P

ZI

O

N E

O

FF

E R

TA

S-305A

14092111

V P P

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A .r vt

SCALE 1 : 100

C1

AP BUILDING 23500 SECTION - 01 /

AP EDIFICIO 23500 SEZIONE - 01

SCALE 1 : 100

A1

AP BUILDING 23500 SECTION - 02 /

AP EDIFICIO 23500 SEZIONE - 02

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI

SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN

PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO

ARMATO 150mm

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

BG

3.08

3.15

B1 S-535

B1 S-533

B1 S-533

B1 S-533

C3 S-531

3.66

3.09

3.08

3.08

3.60

-1.500

-0.200

3.340

6.740

10.140

14.3085%

30%16.341 15.940

TOW 14.390

3.51

3.51

3.51

3.51 3.54

3.54

3.51

3.51

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

3914 13 4

3.08

3.51

3.51

3.08

3.08

3.51

2160826582652160 20850

3.15

B1 S-535

B1 S-533

B1 S-533

A2 S-535

A2 S-535

3.33

3.32

3.33

3.60

3.01

A2 S-531

A1 S-530

B1 S-535

3.61

3.51

3.54

3.51

3.54

3.51

TOW 14.540TOW 14.540

14.420

3.51

5% 5%

5% 5% 3.61

2% -0.600

3.340

6.740

10.140

-1.500

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :5

IDB MHVPP

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

A P

E D

IF

IC

IO

S E

ZI

O

N I

S-306

14092112

V P P

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A .r vt

SCALE 1 : 100

A1

AP BUILDING 23500 SECTION - 02 /

AP EDIFICIO 23500 SEZIONE - 02

SCALE 1 : 100

C1

AP BUILDING 23500 SECTION - 01 /

AP EDIFICIO 23500 SEZIONE - 01

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE

DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm

SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531

3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

SLAB AND FRAMING NOTES /

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

3914 13 4

3.51

3.51

3.54

3.51

3.08

3.51

3.51

3.08

3.08

3.51

2160826582652160 20850

3.54

3.15

B1 S-535

B1 S-533

B1 S-533

A2 S-535

A2 S-535

3.33

3.32

3.33

3.51 3.51

3.60

3.01

A2 S-531

A1 S-530

B1 S-535

3.61

3.51

TOW 14.540 TOW 14.540

-1.500

10.140

6.740

3.340

14.4205% 5%

5% 5% 3.61

2% -0.600

3.51

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

BG

3.08

3.54

3.51

3.513.51

3.51

3.51

3.51

3.15

B1 S-535

B1 S-533

B1 S-533

B1 S-533

C3 S-531

3.51 3.51

3.66

3.09

3.08

3.08

3.60TOW 14.390

-1.500

10.140

6.740

3.340

-0.200

14.3085%

30% 15.940 16.341

KEYPLAN / PIANO STRATEGICO

1:100

0 1 32 4 5 10

SCALE:

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :5

IDB MHVPP

A P

B U

IL

D

IN

G

S

E C

TI

O

N S

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

S

E

ZI

O N

I O P

ZI

O

N E

O

FF

E R

TA

S-306A

14092113

V P P

V ic e n z a

A F H p h a s e

P A P S e n ve lo p e A .r vt

SCALE 1 : 100

C1

AP BUILDING 23500 SECTION - 01 /

AP EDIFICIO 23500 SEZIONE - 01

SCALE 1 : 100

A1

AP BUILDING 23500 SECTION - 02 /

AP EDIFICIO 23500 SEZIONE - 02

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300

CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND

VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA

Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE

LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA

AL VAPORE

3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE

DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm

SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531

3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO

3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

C. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE

BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA

"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN

F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

SLAB AND FRAMING NOTES /

SE_EAVE

17700.000

IGDA

SE_GROUND TOC

-60.000

SE_SECOND TOC

6740.000

SE_FIRST TOC

3340.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

3.08

3.08

3.08

3.08

3.08

3.08

3.09

16950 6550 10550

34050

11.900

13.600

8.500

5.100

1.700

B1 S-535

A2 S-530

C3 S-533

B2 S-532

C2 S-535 C3

S-535 C3

S-531

B1 S-530

B1 S-533

C2 S-532

B3 S-531

3.60 3.60

3.61

2%

2%

2%

30% 30%

13.96314.083

3.66 3.66

3.70

3.70

3.70

3.70

A2 S-530

B1 S-531

10.200

6.800

3.400

-0.200 -0.200

B1 S-309

B1 S-309

A3 S-309

A3 S-309

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51 3.51

3.51

3.51

3.51

3.70

3.70

3.70

3.70

3.51

3.51

3.