Attachment I - 1632846dwg13of24.pdf
PDF 25 MB Posted
- Solicitation number
- N62470-21-R-0015
About this file
This document provides details on a federal solicitation for construction services. The solicitation number is N62470-21-R-0015 and seeks proposals for Phase 2 of the Family Housing Villaggio project at Vicenza, Italy. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Proposals are due on the date specified in the attached solicitation for the construction of additional family housing units at the Villaggio housing complex in Vicenza, Italy. The solicitation includes relevant details on the scope of work, specifications, response requirements, and evaluation criteria.
View the file
Other files
Show 40 more
Latest 50 of 66 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
E
3.15C3 S-535
A1 S-532
C3 S-533
B1 S-533
B1 S-533
C2 S-535
C2 S-535
C2 S-532
C3 S-535
A2 S-530
D2 S-531
A3 S-535
A3 S-535
3.123.123.12 A3
S-534
B1 S-534
3.51
3.66
3.51
3.51
3.51
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3.09
3.70
3.70
3.70
3.51
3.08
3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.60
3.66
3.51
3.51
3.51
3.51
3.60
16.317
TOW 18.600
TOW 18.100
13.600
11.900
10.200
8.500
6.800
5.100
3.400
1.700
16.317
8.03
3.01 3.01
-0.200
SE_FOUNDATION TOC
-1500.000
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:2 :4
IDB MHCE
A P
B U
IL
D
IN
G
S
E C
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
E
S-301
14092102
C E
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A A .r vt
SCALE 1 : 100 (S-101)
A1
AP BUILDING 23400 SECTIONS /
AP EDIFICIO 23400 SEZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO
ARMATO 150mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN
CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532
8.03 1250x1250mm SMOKE HATCH OPENING. REFER TO DETAIL A1 ON SHEET
S-529 / APERTURA SPORTELLO FUMI 1250x1250mm. FARE RIFERIMENTO AL
DETTAGLIO A1 DELL'ELABORATO S-529
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION
GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID
FOR 23300 /
GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE
FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO
VALIDI ANCHE PER IL 23300
H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
NOTE SULLA SOLETTA E
SULL'INTELAIATURA
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
E
3.51
3.51
3.51
3.51 3.51
3.51
3.51
3.51
13.600
11.900
10.200
8.500
5.100
6.800
3.400
1.700
3.08
3.08
3.08
3.08
3.08
3.08
3.15C3 S-535
A1 S-532
C3 S-533
B1 S-533
B1 S-533
C2 S-535
C2 S-535
C2 S-532
C3 S-535
3.60 3.60
3.51 3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.08
3.70
3.70
3.70
3.66 3.66
A2 S-530
D2 S-531
A3 S-535
A3 S-535
3.09
3.123.123.12 A3
S-534
B1 S-534
TOW 18.600
TOW 18.100
16.317 16.317
3.51
8.03
3.01 3.01
3.51 3.51
-0.200
SE_FOUNDATION TOC
-1500.000
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:2 :4
IDB MHCE
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
B
ID
O P
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
E O
P
ZI
O N
E O
FF
E
R
TA
S-301A
14092103
C E
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A A .r vt
SCALE 1 : 100
A1
AP BUILDING 23400 SECTION /
AP EDIFICIO 23400 SEZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO
ARMATO 150mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN
CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532
8.03 1250x1250mm SMOKE HATCH OPENING. REFER TO DETAIL A1 ON SHEET
S-529 / APERTURA SPORTELLO FUMI 1250x1250mm. FARE RIFERIMENTO AL
DETTAGLIO A1 DELL'ELABORATO S-529
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION
GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID
FOR 23300 /
GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE
FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO
VALIDI ANCHE PER IL 23300
H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
EA2
S-220A
3.15 C3
S-535
A2 S-535
B1 S-533
B1 S-533
A2 S-530 A2
S-530
C4 S-531
B1 S-533
A2 S-530
C2 S-535
C2 S-535
A3 S-534
B1 S-534
-1.500
3.513.51 3.51
3.51
3.513.51
3.51
3.51
3.51
3.08
3.08
3.08
3.08
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3.60 3.60
3.51
3.51
3.51
3.51
3.51
3.51
3.15
3.09
3.08
3.51
3.12
8.11
3.12
3.01 3.01
3.51 3.51
TOW 14.835
TOW 18.100 TOW 18.100
TOW 15.640
TOW 14.83514.750
SE_FOUNDATION TOC
-1500.000
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:2 :5
IDB MHCE
A P
B U
IL
D
IN
G
S
E C
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
E
S-302
14092104
C E
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A A .r vt
SCALE 1 : 100 (S-101)
A1
AP BUILDING 23400 SECTIONS /
AP EDIFICIO 23400 SEZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA
COLATA
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION
GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID
FOR 23300 /
GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE
FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO
VALIDI ANCHE PER IL 23300
H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
E
3.513.51 3.51
3.51
3.513.51
3.51
3.51
3.51
3.08
3.08
3.08
3.08
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3.15
C3 S-535
A2 S-535
B1 S-533
B1 S-533
A2 S-530 A2
S-530
C4 S-531
B1 S-533
A2 S-530
C2 S-535
C2 S-535
3.60 3.60
3.51
3.51
3.51
3.51
3.51
3.51
3.15
3.09
3.08
3.51
3.12
8.11
3.12 A3
S-534 B1
S-534
-1.500
14.750TOW 14.835
TOW 18.100 TOW 18.100
TOW 15.640
TOW 14.835
3.01 3.01 -0.200
3.51 3.51
SE_FOUNDATION TOC
-1500.000
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:2 :5
IDB MHCE
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
B
ID
O P
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
E O
P
ZI
O N
E O
FF
E
R
TA
S-302A
14092105
C E
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A A .r vt
SCALE 1 : 100
A1
AP BUILDING 23400 SECTION /
AP EDIFICIO 23400 SEZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA
COLATA
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION
GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID
FOR 23300 /
GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE
FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO
VALIDI ANCHE PER IL 23300
H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
235 14
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
A1 S-214A
A1 S-213A
20850
2160826582652160
3.15
A2 S-535
A2 S-530
B1 S-533
A1 S-533
C2 S-535
A1 S-530 A1
S-530
A2 S-531
A3 S-533A3
S-533
14.419 5% 5%
3.01
3.08
3.08
3.08
3.51 3.51
3.15
3.60
3.51
3.543.54
3.51
3.15
3.51
3.51
3.51
3.51
3.32 3.333.33
3.01
2.860
3.08
5%
3.51
2.8605%
3.08
TOW 14.540 TOW 14.540
SE_FOUNDATION TOC
-1500.000
12 161413 15
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
A1 S-212A
A1 S-211A
A1 S-218A
2160 8265 8265 2160
20850
3.15
A2 S-535
B1 S-533
A1 S-533
B1 S-533
C2 S-535
C2 S-535
C3 S-532
C3 S-527
A3 S-535
14.419
-1.500
5% 5%
3.51 3.51
3.51
3.51
3.08
3.08
3.08
3.15
3.66
3.51
3.51
3.51
3.60 3.51
3.51
3.513.54
3.60
3.31 3.31
3.01
3.233.233.23
TOW 15.640
16.317
15.320
SE_FOUNDATION TOC
-1500.000
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:2 :5
IDB MHCE
A P
B U
IL
D
IN
G
S
E C
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
I
S-303
14092106
C E
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A A .r vt
SCALE 1 : 100 (S-101)
C1
AP BUILDING 23400 CROSS SECTION 1 /
APPARTAMENTO 23400 SEZIONE TRASVERSALE 1
SCALE 1 : 100 (S-101)
A1
AP BUILDING 23400 CROSS SECTION 2 /
APPARTAMENTO 23400 SEZIONE TRASVERSALE 2
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE
DETAIL C3 ON SHEET S-528 / PILASTRO IN CALCESTRUZZO ARMATO C2
SOLO AL PIANO TERRA. VEDI DETTAGLIO C3 SUL FOGLIO S-528
3.31 REINFORCED CONCRETE BEAM 300x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 300x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION
GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID
FOR 23300 /
GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE
FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO
VALIDI ANCHE PER IL 23300
H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
235 14
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
20850
2160826582652160
3.08
3.08
3.08
3.51 3.51
3.15
A2 S-535
A2 S-530
B1 S-533
A1 S-533
C2 S-535
3.60
3.51
3.543.54
3.51
3.15
3.51
3.51
3.51
3.51
3.32 3.333.33
A1 S-530
A1 S-530
A2 S-531
A3 S-533A3
S-533
TOW 14.540 TOW 14.54014.419
2.8602.860 5% 5%
5% 5%
3.01
3.08 3.08
SE_FOUNDATION TOC
-1500.000
12 161413 15
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
2160 8265 8265 2160
20850
3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.15
A2 S-535
B1 S-533
A1 S-533
B1 S-533
C2 S-535
C2 S-535
3.66
3.51
3.51
3.51
3.60
3.51
3.51
3.51 3.54
3.23
3.51 3.51
3.60
C3 S-532
C3 S-527
A3 S-535
TOW 15.640
16.317
3.31 3.31
14.419
-1.500
30%
5% 5%
3.01 3.01
15.320
SE_FOUNDATION TOC
-1500.000
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:2 :5
IDB MHCE
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
B
ID
O P
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
I O P
ZI
O
N E
O
FF
E R
TA
S-303A
14092107
C E
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A A .r vt
SCALE 1 : 100
C1
AP BUILDING 23400 CROSS SECTION 1 /
AP EDIFICIO 23400 SEZIONE TRASVERSALE 1
SCALE 1 : 100
A1
AP BUILDING 23400 CROSS SECTION 2 /
AP EDIFICIO 23400 SEZIONE TRASVERSALE 2
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.23 REINFORCED CONCRETE COLUMN C2 ONLY AT GROUND FLOOR. SEE
DETAIL C3 ON SHEET S-528 / PILASTRO IN CALCESTRUZZO ARMATO C2
SOLO AL PIANO TERRA. VEDI DETTAGLIO C3 SUL FOGLIO S-528
3.31 REINFORCED CONCRETE BEAM 300x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 300x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
G. BUILDING 23400 AND 23300 ARE IDENTICAL APART FROM FOUNDATION
GEOMETRY. FIRST FLOOR AND ABOVE DRAWINGS FOR 23400 ARE ALSO VALID
FOR 23300 /
GLI EDIFICI 23400 E 23300 SONO IDENTICI A PARTE LA GEOMETRIA DELLE
FONDAMENTA. I DISEGNI DEL PRIMO PIANO E SUPERIORI PER IL 23400 SONO
VALIDI ANCHE PER IL 23300
H. SEE G-002 FOR FURTHER INFORMATION ON BUILDING NUMBERS AND TYPE
DESIGNATION AND SHEETS AS001 FOR BUILDING LOCATION /
VEDERE G-002 PER ULTERIORI INFORMAZIONI SUI NUMERI DEGLI EDIFICI E LA
DESIGNAZIONE DEL TIPO E LE TAVOLE AS001 PER L'UBICAZIONE DEGLI EDIFICI
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
ABG CDE
3.08
3.08
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3350 450 3450 980 2160
3.70
3.15
3.08
3.01
B1 S-533
B2 S-532
B1 S-532
B1 S-533
C3 S-535
A1 S-532
A2 S-530
A2 S-535
C3 S-531
B1 S-533
B1 S-533
B1 S-533
B2 S-532
B2 S-532
B2 S-532 B3
S-531
3.51
3.60
3.12
17.543
3.09
B1 S-532
3.08
3.08
5%
TOW 18.200
TOW 19.450
TOW 2.646
TOW 15.640
-1.500
14.157
10.140
6.740
3.340
-0.200
1.700
5.100
8.500
11.900
13.600
10.200
6.800
3.400
17.216
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :4
IDB MHVPP
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
A P
E D
IF
IC
IO
S E
ZI
O
N E
S-304
14092108
V P P
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A .r vt
SCALE 1 : 100
A1
AP BUILDING 23500 SECTION /
AP EDIFICIO 23500 SEZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN
CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
ABG CDE
3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3350 450 3450 980 2160
3.70
3.15
3.08
3.01
B1 S-533
B2 S-532
B1 S-532
B1 S-533
C3 S-535
A1 S-532
A2 S-530
A2 S-535
C3 S-531
B1 S-533
B1 S-533
B1 S-533
B2 S-532
B2 S-532
B2 S-532 B3
S-531
3.51
3.51 3.51
3.60
3.12
14.152
3.51
TOW 15.640
TOW 19.450
3.09
B1 S-532
3.08
3.08
5%
TOW 18.200
2.646
3.400
6.800
10.200
13.600
10.140
6.740
3.340
-0.200
1.700
5.100
8.500
11.900
17.216
-1.500
3.61 3.61
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :4
IDB MHVPP
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
B
ID
O P
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
E O
P
ZI
O N
E O
FF
E
R
TA
S-304A
14092109
V P P
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A .r vt
SCALE 1 : 100
A1
AP BUILDING 23500 SECTION /
AP EDIFICIO 23500 SEZIONE
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN
PREDALLES 250mm
3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-532 / SCALA IN
CALCESTRUZZO GETTATO IN OPERA, VEDI IL DETTAGLIO SUL FOGLIO S-532
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
ABG CDE
3350 450 3450 980 2160
3.08
3.08
3.08
3.08
3.08
3.08
3.15
3.01
B1 S-533
C3 S-535
A2 S-530
A2 S-530
A3 S-535
A2 S-535
A2 S-535
C3 S-531
3.60
3.09
3.61
B1 S-533
B1 S-533
A2 S-535
3.61 14.279
-0.200 -0.200
-1.500
3.51
3.51
3.51
3.51
5%
16.340 30%
10.140
6.740
3.340
15.292
TOW 15.640 TOW 15.640
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.15
3.01
3.51 3.51
3.66
3.60
3.51
3.09
3.51 3.61
3.61
3.51
3.51
3.51
3.51
3.51
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
1 7 11 12 26730
16950 6870 2910
3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.15
A2 S-530
B1 S-533
B1 S-533
B3 S-531 C3
S-531
B1 S-533
A2 S-530
B1 S-533
C3 S-531
A2 S-535
A2 S-535
A2 S-535
3.60
3.093.09
3.08
3.08
3.08
B2 S-530
-1.500-1.500
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
13.540
14.750
10.140
6.740
3.340
-0.200
14.107
17.342
TOW 15.500
TOW 18.200
TOW 19.450
3.61
3.08
3.08
TOW 2.646
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51 3.51
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :4
IDB MHVPP
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
A P
E D
IF
IC
IO
S E
ZI
O
N I
S-305
14092110
V P P
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A .r vt
SCALE 1 : 100
C1
AP BUILDING 23500 SECTION - 01 /
AP EDIFICIO 23500 SEZIONE - 01
SCALE 1 : 100
A1
AP BUILDING 23500 SECTION - 02 /
AP EDIFICIO 23500 SEZIONE - 02
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN
PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO
ARMATO 150mm
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
ABG CDE
3350 450 3450 980 2160
3.08
3.08
3.08
3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.15
3.01
B1 S-533
C3 S-535
A2 S-530
A2 S-530
A3 S-535
A2 S-535
A2 S-535
C3 S-531
3.51 3.51
3.66
3.60
3.51
14.279
3.09
3.51
-0.200
3.61
B1 S-533
B1 S-533
A2 S-535
3.61
TOW 15.640
TOW 18.200
18.200
TOW 15.640
-1.500 -1.500
15.500
14.750
3.51
3.51
3.51
3.51
3.51
3.51
3.51
30% 16.340
5%
10.140
6.740
3.340
15.292
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
1 7 11 12 26730
16950 6870 2910
3.51
3.51
3.51
3.51 3.51
3.51
3.51
3.51
3.08
3.08
3.08
3.15
A2 S-530
B1 S-533
B1 S-533
B3 S-531 C3
S-531
B1 S-533
A2 S-530
B1 S-533
C3 S-531
A2 S-535
A2 S-535
A2 S-535
3.60
17.342
3.093.09
3.08
3.08
3.08
TOW 15.500
TOW 19.450
TOW 2.646
-1.500
A2 S-530
TOW 18.200
-1.500
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
10.140
6.740
3.340
-0.200
14.107 13.540
14.750
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :5
IDB MHVPP
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
B
ID
O P
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
I O P
ZI
O
N E
O
FF
E R
TA
S-305A
14092111
V P P
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A .r vt
SCALE 1 : 100
C1
AP BUILDING 23500 SECTION - 01 /
AP EDIFICIO 23500 SEZIONE - 01
SCALE 1 : 100
A1
AP BUILDING 23500 SECTION - 02 /
AP EDIFICIO 23500 SEZIONE - 02
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO
250mm
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI
SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN
PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO
ARMATO 150mm
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
BG
3.08
3.15
B1 S-535
B1 S-533
B1 S-533
B1 S-533
C3 S-531
3.66
3.09
3.08
3.08
3.60
-1.500
-0.200
3.340
6.740
10.140
14.3085%
30%16.341 15.940
TOW 14.390
3.51
3.51
3.51
3.51 3.54
3.54
3.51
3.51
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
3914 13 4
3.08
3.51
3.51
3.08
3.08
3.51
2160826582652160 20850
3.15
B1 S-535
B1 S-533
B1 S-533
A2 S-535
A2 S-535
3.33
3.32
3.33
3.60
3.01
A2 S-531
A1 S-530
B1 S-535
3.61
3.51
3.54
3.51
3.54
3.51
TOW 14.540TOW 14.540
14.420
3.51
5% 5%
5% 5% 3.61
2% -0.600
3.340
6.740
10.140
-1.500
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :5
IDB MHVPP
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
A P
E D
IF
IC
IO
S E
ZI
O
N I
S-306
14092112
V P P
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A .r vt
SCALE 1 : 100
A1
AP BUILDING 23500 SECTION - 02 /
AP EDIFICIO 23500 SEZIONE - 02
SCALE 1 : 100
C1
AP BUILDING 23500 SECTION - 01 /
AP EDIFICIO 23500 SEZIONE - 01
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE
DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
3914 13 4
3.51
3.51
3.54
3.51
3.08
3.51
3.51
3.08
3.08
3.51
2160826582652160 20850
3.54
3.15
B1 S-535
B1 S-533
B1 S-533
A2 S-535
A2 S-535
3.33
3.32
3.33
3.51 3.51
3.60
3.01
A2 S-531
A1 S-530
B1 S-535
3.61
3.51
TOW 14.540 TOW 14.540
-1.500
10.140
6.740
3.340
14.4205% 5%
5% 5% 3.61
2% -0.600
3.51
SE_GROUND TOC
-60.000
SE_FIRST TOC
3340.000
SE_SECOND TOC
6740.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
BG
3.08
3.54
3.51
3.513.51
3.51
3.51
3.51
3.15
B1 S-535
B1 S-533
B1 S-533
B1 S-533
C3 S-531
3.51 3.51
3.66
3.09
3.08
3.08
3.60TOW 14.390
-1.500
10.140
6.740
3.340
-0.200
14.3085%
30% 15.940 16.341
KEYPLAN / PIANO STRATEGICO
1:100
0 1 32 4 5 10
SCALE:
M
AR
K D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :5
IDB MHVPP
A P
B U
IL
D
IN
G
S
E C
TI
O
N S
B
ID
O P
TI
O
N A
P E
D
IF
IC
IO
S
E
ZI
O N
I O P
ZI
O
N E
O
FF
E R
TA
S-306A
14092113
V P P
V ic e n z a
A F H p h a s e
P A P S e n ve lo p e A .r vt
SCALE 1 : 100
C1
AP BUILDING 23500 SECTION - 01 /
AP EDIFICIO 23500 SEZIONE - 01
SCALE 1 : 100
A1
AP BUILDING 23500 SECTION - 02 /
AP EDIFICIO 23500 SEZIONE - 02
SHEET KEYNOTES / NOTE CHIAVE
DELLA TAVOLA:
3.01 250mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB WITH Ø12/300
CENTERED EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND
VAPOR RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA
Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE
LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA
AL VAPORE
3.08 250mm CAST IN PLACE CONCRETE REINFORCED SLAB WITH Ø12/150 EACH
WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN
CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150
SUPERIORE ED INFERIORIN OGNI DIREZIONE. VEDI PIANTA PER PROSPETTO
3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU
3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm
3.32 REINFORCED CONCRETE BEAM 400x700mm ONLY AT FIRST FLOOR. SEE
DETAIL A2 ON SHEET S-531 / TRAVE IN CALCESTRUZZO ARMATO 400x700mm
SOLO AL PRIMO PIANO. VEDERE IL DETTAGLIO A2 SUL FOGLIO S-531
3.33 REINFORCED CONCRETE BEAM 460x700mm ONLY AT FIRST FLOOR / TRAVE IN CALCESTRUZZO ARMATO 460x700mm SOLO AL PRIMO PIANO
3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm
3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO
3.60 PRESTRESSED PREDALLES REINFORCED SLAB TRELLIS 290mm / TRALICCI SOLAIO IN PREDALLES PRECOMPRESSE 290mm
3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRALICCI SOLAIO IN PREDALLES 250mm
3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm
A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /
QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI
B. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI
STRUTTURALI
C. REFER TO SHEET S-005 FOR "WIND LOADS" /
FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"
D. REFER TO SHEET S-534 FOR TYPICAL PILE AND PILE CAP DETAILS /
FARE RIFERIMENTO ALLA TAVOLA S-534 PER I DETTAGLI TIPICI DEI PALI E DEI
PLINTI
E. REFER TO DETAIL A3 ON SHEET S-528 FOR "CONTINUITY OF CONCRETE
BEAM REINFORCEMENT AT CORNERES AND INTERSECTIONS" /
FARE RIFERIMENTO AL DETTAGLIO A3 DELLA TAVOLA S-528 PER LA
"CONTINUITÀ DELL'ARMATURA DELLE TRAVI IN
F. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /
VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL
GETTO
SLAB AND FRAMING NOTES /
SE_EAVE
17700.000
IGDA
SE_GROUND TOC
-60.000
SE_SECOND TOC
6740.000
SE_FIRST TOC
3340.000
SE_THIRD TOC
10140.000
SE_PENTHOUSE TOC
13540.000
3.08
3.08
3.08
3.08
3.08
3.08
3.09
16950 6550 10550
34050
11.900
13.600
8.500
5.100
1.700
B1 S-535
A2 S-530
C3 S-533
B2 S-532
C2 S-535 C3
S-535 C3
S-531
B1 S-530
B1 S-533
C2 S-532
B3 S-531
3.60 3.60
3.61
2%
2%
2%
30% 30%
13.96314.083
3.66 3.66
3.70
3.70
3.70
3.70
A2 S-530
B1 S-531
10.200
6.800
3.400
-0.200 -0.200
B1 S-309
B1 S-309
A3 S-309
A3 S-309
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51
3.51 3.51
3.51
3.51
3.51
3.70
3.70
3.70
3.70
3.51
3.51
3.
This is the start of the file's text. The full file is on GovTribe.