Attachment I - 1632846dwg08of24.pdf

PDF 27 MB Posted

Attached to
P-91330, Phase 2 Family Housing Villaggio at Vicenza, Italy
Solicitation number
N62470-21-R-0015
Issued by

About this file

This document provides details on a federal solicitation for construction services. The solicitation number is N62470-21-R-0015 and seeks offers for Phase 2 of the Family Housing Villaggio project at Vicenza, Italy. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Offerors should submit responses in accordance with the attached solicitation document by the specified deadline in order to be considered for award. The solicitation involves construction work related to expanding family housing at a U.S. military base in Italy. Relevant response dates, award timing, pricing terms, and other salient procurement details are contained within the attached solicitation file.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_21JUN2022.pdf PDF
N6247021R0015 Amend 0015.pdf PDF
N6247021R0015 Amend 0014.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247021R0015 Amend 0013.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_10JUN2022.pdf PDF
N6247021R0015 Amend 0012.pdf PDF
Attachment W - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment X - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247021R0015 Amend 0011.pdf PDF
Attachment V - Revised 1632468 Drawings Amendment 0010.pdf PDF
Attachment U - Revised 1632468 Specification Amendment 0010.pdf PDF
N6247021R0015 Amend 0010.pdf PDF
Attachment T - 1632846 Foundation and Misc Revisions Drawings 02of 02.pdf PDF
Attachment R - 1632846 Foundation and Misc Revisions Specifications.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247021R0015 Amend 0009.pdf PDF
Attachment J - PSC Italian Revised March 24 2022.pdf PDF
Attachment S - 1632846 Foundation and Misc Revisions Drawings 01 of 02.pdf PDF
N6247021R0015 Amend 0008.pdf PDF
N6247021R0015 Amend 0007.pdf PDF
Attachment Q Revised 1632468 Drawings Amendment 0006.pdf PDF
N6247021R0015 Amend 0006.pdf PDF
Attachment P Revised 1632468 Specification Amendment 0006.pdf PDF
N6247021R0015 Amend 0005.pdf PDF
Attachment M Pre-proposal Conference Attendee Log.pdf PDF
Attachment N Revised 1632846 Specifications.pdf PDF
Attachment O Revised 1632846 Drawings.pdf PDF
N6247021R0015 Amend 0004.pdf PDF
N6247021R0015 Amend 0003.pdf PDF
N6247021R0015 Amend 0002.pdf PDF
N6247021R0015 Amend 0001.pdf PDF
Attachment I - 1632846dwg20of24.pdf PDF
Attachment I - 1632846dwg09of24.pdf PDF
Attachment I - 1632846dwg04of24.pdf PDF
Attachment I - 1632846dwg10of24.pdf PDF
Attachment I - 1632846dwg14of24.pdf PDF
Attachment I - 1632846dwg11of24.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment I - 1632846dwg24of24.pdf PDF
Attachment I - 1632846dwg13of24.pdf PDF
Attachment H - Specifications.pdf PDF
Attachment I - 1632846dwg02of24.pdf PDF
Attachment I - 1632846dwg03of24.pdf PDF
Attachment I - 1632846dwg18of24.pdf PDF
Attachment I - 1632846dwg12of24.pdf PDF
Attachment L - DWG Index.pdf PDF
Attachment I - 1632846dwg23of24.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
N6247021R0015.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A4

CURBING DETAILS / PARTICOLARI CORDOLATURE

NO SCALE / NON IN SCALA

C4

BOLLARD DETAIL/PARTICOLARE DISSUASORE

NO SCALE / NON IN SCALA

A3

JOINT SEALANT DETAILS/PARTICOLARE SIGILLANTE PER GIUTI

NO SCALE / NON IN SCALA

B1

CONNECTION EXISTING ASPHALT PAVEMENT

NON IN SCALA

NO SCALE

CONNESSIONE PAV. IN ASFALTO ESISTENTE

A1

ASPHALT PAVEMENT SECTION

NON IN SCALA

NO SCALE

SEZIONE PAVIMENTAZIONE IN ASFALTO

C1

CONCRETE DRIVEWAY PAVEMENT SECTION

NON IN SCALA

NO SCALE

SEZIONE PAVIMENTAZIONE IN CALCESTRUZZO

C3

NON IN SCALA

PAVIMENTAZIONE IN CALCESTRUZZO -

CONCRETE PAVEMENT - JOINT DETAILS

NO SCALE

PARTICOLARI GIUNTO

D1

CS101

B3

CS101

D1

CS101

C3

C-501

A3

CS101

A2

CS101

NOTES:

1. REFER TO LANDSCAPE PLANS FOR ADDITIONAL PAVEMENT FINISH, COLOR AND JOINT REQUIREMENTS / ARE

RIFERIMENTO ALLE PIANTE DELLA SISTEMAZIONE A VERDE PER LA FINITURA ADDIZIONALE DELLA

PAVIMENTAZIONE, COLORI E GIUNTI RICHIESI.

2. MINIMUM THICKNESS FOR CONCRETE PAVEMENT: h d

= 200 (DRIVEWAY) /

SPESSORE MINIMO PER PAVIMENTAZIONI IN CLS: h d

= 200 (VIALETTO)

3. REFER TO CIVIL PLANS FOR DESIGN INTENT OF CONCRETE JOINT LAYOUT. PROVIDE JOINT LAYOUT PER ACI

330.1 AND APPLICABLE GUIDANCE IN ACD 330R-08. SUBMIT SHOP DRAWINGS OF PROPOSED JOINTING FOR

REVIEW AND ACCEPTANCE. /

FARE RIFERIMENTO A PIANI CIVILI PER ILA PROGETTAZIONE DEL POSIZIONAMENTO DEI GIUNTI. FORNITURA E

POSA IN OPERA DI GIUNTI IN RIFERIMENTO A ACI 330.1 E GUIDA DI APPLICAZIONE ACD330R-08.

SOTTOMETTERE DISEGNI COSTRUTTIVI PER I GIUNTI PROPOSTI PER REVISIONE E ACCETTAZIONE

4. REFER TO JOINT SEALANT DETAILS. / FARE RIFERIMENTO AL PARTICOLARE DELLA SIGILLATURA DEI GIUNTI

5. REINFORCEMENT: ASTM A1064, 150x150 - MD52xMD52, WELDED WIRE REINFORCEMENT, GRADE 60. /

ARMATURA: ASTM A1064, 150x150 MD52xMD52 RETE ELETTROSALDATA, CLASSE 60

6. CONCRETE PAVEMENT, MINIMUM FLEXURAL STRENGTH = 4.5 MPa (UNO). /

PAVIMENTAZIONE IN CALCESTRUZZO, RESISTENZA ALLA FLESSIONE = 4.5 MPa (UNO)

CONCRETE PAVEMENT (SEE NOTES) /

PAVIMENTAZIONE IN CLS (VEDI NOTE)

COMPACTED AGGREGATE BASE (300 MIN) /

AGGREGATO COMPATTATO (300 MIN)

COMPACTED SUBGRADE 95% ASTM D1557, LIME STABILIZED /

SOTTOFONDO COMPATTATO AL 95%, STABILIZZAZIONE DELLA CALCE

h d

WIDTH SHOWN ON PLANS/

LARGHEZZA INDICATA IN PIANTA

REINFORCEMENT / ARMATURA

75 CLR (TYP)

JOINT/ GIUNTO

CONTRACTION JOINT / GIUNTO DI CONTRAZIONE THICKENED EDGE / RINGROSSO BORDO

CONSTRUCTION JOINT / GIUNTO DI COSTRUZIONE ISOLATION JOINT / GIUNTO DI ISOLAMENTO

THICKENED EDGE BUTT JOINT FOR LONGITUDINAL OR TRANSVERSE JOINTS/

RINGROSSO DEL BORDO DI GIUNZIONE PER GIUNTI LONGITUDINALI O TRASVERSALI

CONCRETE SLAB/

SOLLETTA IN CLS.

BUILDING, LOADING DOCK, WALL,

OR EXISTING PAVEMENT/

EDIFICIO, PIANO DI CARICO, MURI O

PAVIMENTAZIONI ESISTENTI

h d

SEE THICKENED EDGE DETAIL/

VEDERE PARTICOLARE BORDO

RINGROSSATO

PREFORMED NON-EXTRUDING

JOINT FILLER MATERIAL /

MATERIALE NON ESTRUSO

PREFORMATO DI

RIEMPIMENTO GIUNTO

h d h d

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA DEI GIUNTI

SEE THICKENED EDGE DETAIL

VEDERE PARTICOLARE BORDO

RINGROSSATO

h d

1 200 h d h d

CONCRETE PAVEMENT/

PAVIMENTAZIONE IN CLS.

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA DEI GIUNTI

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE

SIGILLATURA DEI GIUNTI

SAWCUT GRID FOR 150 PAVEMENT 2.50m x 2.50m/

SEGARE IL RETICOLO PER 150 PAVIMENTAZIONE 2.50m x 2.50m

150 SCHEDULE 40 PIPE (UNO), ASTM-A53 STEEL,

FILLED WITH CONCRETE (SEE NOTE). /

150 TUBO 40 (UNO), ASTM-A53 ACCIAIO, RIEMPITO IN

CLS (VEDERE NOTA)

NOTE:

1. SLOPE CONCRETE TO SHED WATER. PAINT PIPE AND CONCRETE TOP

"SAFETY YELLOW" AFTER INSTALLATION AND PRIMING (UNO). /

PENDENZA DI CALCESTRUZZO ALL'ACQUA DI SCARICO. VERNICIARE IL

TUBO ED IL CLS SULLA SOMMITA' CON VERNICE DI "SICUREZZA GIALLO"

DOPO L'INSTALLAZIONE (UNO)

2. COORDINATE BOLLARD LOCATIONS WITH FOUNDATIONS AND UTILITIES. /

COORDINARE IL POSIZIONAMENTO DEI DISSUASORI CON LE FONDAZIONI E

LE LINEE DI SERVIZIO

SLOPE TO DRAIN /

PENDENZA PER DRENAGGIO

MIN

ASPHALT COURSES/

STRATO DI ASFALTO

AGGREGATE

BASE COURSE/

STRATO DI BASE

AGGREGATO

EXST ASPHALT SURFACE/

SUPERFICIE IN ASFALTO ESISTENTE

EXST BASE

COURSE/ STRATO DI BASE

ESISTENTE

SAW CUT /

SEGARE

TACK COAT/

MANO DI ATTACCO

PRIME COAT/

STRATO DI

PRIMER

3mm (MAX)

T

INDUCED CRACK/

SAWCUT/SEGARE

SAWED CONTRACTION JOINT (WALKS ONLY) /

GIUNTO DI CONTRAZIONE SEGATO (SOLO MURI)

NOTES/NOTE:

1. DETAILS APPLY TO CONCRETE PAVEMENT AND CONVENTIONAL CONCRETE PEDESTRIAN WALKS. /

PARTICOLARI DA APPLICARE NELLA PAVIMENTAZIONI IN CALCESTRUZZO CONVENZIONALI E NEI

MARCIAPIEDI IN CALCESTRUZZO

2. FOR CONCRETE PAVEMENT, LOW POINT OF SEALANT SHALL BE 3mm TO 6mm BELOW TOP OF CONCRETE, UNLESS NOTED

OTHERWISE. /

PER PAVIMENTAZIONI IN CALCESTRUZZO, IL PUNTO BASSO DI SIGILLANTE DEVE ESSERE DA 3mm A 6mm

SOTTO LA SUPERFICIE DEL CALCESTRUZZO, A MENO DI ALTRI NOTI

PAVEMENT

SURFACE/

SUPERFICIE

PAVIMENTATA

W W

W

D

T

INDUCED CRACK/

INITIAL SAWCUT /

TAGLIO INIZIALE(3mm)

D

D

BACKER MATERIAL/

MATERIALE DI

CHIUSURA

CONTRACTION JOINT

GIUNTO DI CONTRAZIONE

CONSTRUCTION JOINT /

GIUNTO DI COSTRUZIONE

ISOLATION/EXPANSION JOINT /

GIUNTO DI ISOLAMENTO/ESPANSIONE

JOINT BOTTOM/

FONDO DEL GIUNTO

W = WIDTH OF SEALANT RESERVOIR = 10 MAXIMUM (CONTRACTION AND CONSTRUCTION JOINTS)

W = LARGHEZZA DEL SERBATOIO DI SIGILLANTE = 10 MASSIMO (GIUNTI DI CONTRAZIONE E COSTRUZIONE)

D = DEPTH OF SEALANT RESERVOIR = 1.0 TO 1.5 x W /PROFONDITA' DELLA RISERVA DI SIGILLANTE = 1.0 FINO A 1.5W

T = DEPTH OF INITIAL SAWCUT = 1/4 SLAB THICKNESS (WHEN USING CONVENTIONAL WET SAW-CUTTING) /

T= PROFONDITA' DEL TAGLIO INIZIALE =

SPESSORE SOLETTA ( QUANDO SI UTILIZZA LA SEGA A UMIDO TRADIZIONALE)

JOINT

SEALENT/

SIGILLANTE DEL

GIUNTO

CREPE PROVOCATE

JOINT BOTTOM/

FONDO DEL GIUNTO

JOINT

SEALENT/

SIGILLANTE DEL

GIUNTO

PAVEMENT

SURFACE/

SUPERFICIE

PAVIMENTATA

JOINT

SEALENT/

SIGILLANTE DEL

GIUNTO

BACKER MATERIAL/

MATERIALE DI

CHIUSURA

BACKER MATERIAL/

MATERIALE DI

CHIUSURA

JOINT FILLER/

RIEMPIMENTO DEL

GIUNTO

PAVEMENT

SURFACE/

SUPERFICIE

PAVIMENTATA

CREPE PROVOCATE

NOTES/ NOTE:

1. COMPACT SUBGRADE AND BASE COURSES TO 95% ASTM D698, UNO. /

COMPATTARE STRATO DI BASE E STRATO DI SOTTOFODO AL 95% ASTM D698, UNO

2. GRANULAR MIX BASE COURSE SHALL CONSIST OF THE FOLLOWING: 250 DRAINAGE STONE LAYER

(AASHTO M43 #57) STABILIZED WITH TOP LAYER OF CHOKE STONE (AASHTO M43 #89) OVER 100

STONE SEPARATION LAYER (AASHTO M147, GRADING "C"). / IL MIX BASE E COMPOSTO: 250

STRATO DI GHIAIA PER DRENAGGIO (AASHTO M43 #57) STABILIZZATO CON UNO STRATO DI ROCCIA

DI CARBONE SOPRA 100 STRATO DI SEPARAZIONE (AASHTO M147, SISTEMAZIONE DEL TERRENO

"C").

50 ASPHALT BINDER COURSE

LAYER / 50 STRATO DI BINDER

DI ASFALTO

90 ASPHALT BASE LAYER /

90 STRATO BASE DI ASFALTO

50 ASPHALT SURFACE COURSE/

50 STRATO DI ASFALTO

350 UNBOUND GRANULAR MIX BASE COURSE

350 STRATO BASE MIX GRANULARE NON ASSOCIATO

400 LIME STABILIZATION

400 STABILIZZAZIONE DELLA CALCE

COMPACTED SUBGRADE /

SOTTOFONDO COMPATTATO

ROAD ASPHALT / ASFALTO STRADALE

50 ASPHALT BINDER COURSE LAYER/

50 STRATO DI BINDER DI ASFALTO

80 ASPHALT BASE LAYER /

80 STRATO BASE DI ASFALTO

40 ASPHALT SURFACE COURSE/

40 STRATO DI ASFALTO

350 UNBOUND GRANULAR MIX BASE COURSE

350 STRATO BASE MIX GRANULARE NON ASSOCIATO

400 LIME STABILIZATION

400 STABILIZZAZIONE DELLA CALCE

COMPACTED SUBGRADE /

SOTTOFONDO COMPATTATO

COURTYARD ASPHALT / ASFALTO CORTILE

R50

PVMT

R50

1:1

PVMT

CONC

CONC

STANDARD CURB/

TDC

:1

R

R

NOTES:

1. CURBS SHALL CONFORM TO THE RADII SHOWN ON PLANS. /

I CORDOLO SARANNO CONFORMI AI RAGGI INDICATI SULLA PIANTA

2. ALL EXPOSED SURFACES SHALL BE FINISHED SMOOTH. / TUTTE LE SUPERFICI ESPOSTE

SARANNO LISCE

3. CURBS MAY BE PRECAST. / I CORDOLI POTRANNO ESSERE PREFABBRICATI.

4. FORMS SHALL BE STEEL. / LE CASSEFORME SARANNO IN ACCIAIO

5. SEE PAVEMENT DETAIL FOR TYPE OF BEDDING. / VEDERE PARTICOLARI DELLA

PAVIMENTAZIONE PER IL TIPO DI RINTERRO

TOP OF CURB/

CIMA DEL CORDOLO

600 (UNO)

FINISH GRADE AT GUTTER/

QUOTA TERRENO ALLA CUNETTA

BOTTOM OF CURB/

FONDO DEL CORDOLO

PVMT

CONC/CLS

M

I N

M

I N

150 CURB & GUTTER / CORDOLO E CANALETTA

TURNED DOWN CURB (TDC) ELEVATION /

100 CURB & GUTTER /CORDOLO E CANALETTA

150 CURB / CORDOLO

CORDOLO SMUSSATO IN BASSO (TDC) PROSPETTO

CORDOLO STANDARD

L a s t s a v e d b y

M

A R

K G

A R

L A

N D

L a s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

P

-9

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

BDFTJGMAG

C-501

B1

CONCRETE WALK/MARCIAPIEDE IN CALCESTRUZZO

NO SCALE / NON IN SCALA

C2

CONCRETE WALK - JOINT DETAIL

NON IN SCALA

NO SCALE

MARCIAPIEDE IN CLS/PARTICOLARE GIUNTO

C4

CS101

B4

CS101

WALK WIDTH / LONGITUDINAL CONTRACTION JOINT /

LARGHEZZA MARCIAPIEDE GIUNTI DI CONTRAZIONE LONGITUDINALI

<1800 NONE / NESSUNO

1800 TO <2400 ONE ALONG WALK AT CENTERLINE / UNO LUNGO IL CENTRO DEL MARCIAPIEDE

2400 TO 3600 TWO ALONG WALK AT THIRD POINTS / DUE LUNGO IL TERZO DEL MARCIAPIEDE

ISOLATION JOINT WHERE WALK ABUTS

CURB, PAVEMENT OR STEPS/

GIUNTI DI ISOLAMENTO IN PROSSIMITA' DI

CORDOLI, PAVIMENTAZIONI O GRADINI

LONGITUDINAL

CONTRACTION JOINT/

GIUNTI LONGITUDINALI DI

CONTRAZIONE

TRANSVERSE EXPANSION JOINT/

GIUNTI DI ESPANSIONE TRASVERSALI

1500 TYP

15m OR MATCH JOINTS OF CURB WHEN ADJACENT (SEE NOTE1) /

15m OPPURE INCONTRARE I GIUNTI DEL CORDOLO QUANDO SONO

ADIACENTI

(VEDI NOTA 1)

S E

E

P

L A

N S

(SEE NOTE 1)

(VEDI NOTA 1)

NOTES/NOTE:

1. REFER TO CJ100-SERIES SHEETS FOR DESIGN INTENT OF CONCRETE JOINT LAYOUT. /

FARE RIFERIMENTO ALLE FOGLI DELLA SERIE CJ100 PER LA PROGETTAZIONE DEL DISPOSIZIONE

DEL GIUNTO CONCRETO.

2. REFER TO JOINT SEALANT DETAILS. /

VEDERE PARTICOLARE SIGILLATURA GIUNTI

CONTRACTION

JOINT, 25 DEEP

(SEE NOTE 2)/GIUNTO DI

CONTRAZIONE ,

PROFONDITA' 25

EXPANSION JOINT (SEE NOTE 2)/

GIUNTO DI ESPANSIONE (VEDI NOTA 2)

150x150 - MW9xMW9

WELDED WIRE FABRIC/

RETE ELETTROSALDATA

SMOOTH, COMPACTED SUBGRADE

SOTTOFONDO LISCIO COMPATTATO

100 AGGREGATE

BASE COURSE/

STRATO DI BASE

AGGREGATO

75 CLR AT

JOINTS (TYP)

GIUNTO (TIP)

NOTE/NOTA:

COMPACT SUBGRADE AND AGGREGATE BASE COURSES TO 95% ASTM D1557, UNO. /

SOTTOFONDO E STRATO DI BASE AGGREGATO COMPATTATO AL 95% ASTM D1557,UNO

LONGITUDINAL SECTION / SEZIONE LONGITUDINALE

PARTIAL PLAN / PIANTA PARZIALE

h d h d

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA GIUNTI

BUTT JOINT FOR LONGITUDINAL OR TRANSVERSE JOINTS/

GIUNTO DI TESTA PER GIUNTI LONGITUDINALI O TRASVERSALI

h d h d

CONCRETE SLAB/

SOLETTA IN CALCESTRUZZO

BUILDING OR STRUCTURE/

EDIFICIO O STRUTTURA

CONTRACTION JOINT / GIUNTO DI CONTRAZIONE

CONSTRUCTION JOINT / GIUNTO DI COSTRUZIONE

ISOLATION JOINT / GIUNTO DI ISOLAMENTO

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA GIUNTI

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA

GIUNTI

PREFORMED NON-EXTRUDING

JOINT FILLER MATERIAL /

MATERIALE NON ESTRUSO

PREFORMATO DI RIEMPIMENTO GIUNTO

1 800

PVMT

300 450

2 - 13 (MIN)

38 38

A1

PRECAST WHEEL STOP/FERMARUOTE PREFABBRICATI

NO SCALE / NON IN SCALA

ELEVATION / PROSPETTO

END VIEW / VISTA LATERALE

19 DIA STL RODS 750 LONG BOTH

ENDS/ BULLONI DIAM 19 OGNI 750

LUNGO ENTRAMBI I LATI

6 0006 000

S

P

A

1 500 2 4002 400

(2400 MIN IF VAN

ACCESSIBLE)

A3

PARKING SPACE MARKINGS/STRISCE POSTO PARCHEGGIO

NO SCALE / NON IN SCALA

DOUBLE PARKING STALL /

DUE POSTI PARCHEGGI

PARKING STALL ABUTTING OPEN SPACE /

POSTO PARCHEGGIO IN AREA APERTA

ACCESSIBLE PARKING STALL /

POSTO PARCHEGGIO ACCESSIBILE

OPEN SPACE/

SPAZIO APERTO

FACE OF CURB/

FACCIA DEL CORDOLO

120 WIDE WHITE STRIPE/

STRISCE LARGHE 120

BIANCHE

WHEEL STOP

(TYP) /

BLOCCA

RUOTE (TIP)

120 WIDE YELLOW

STRIPE, TYP/

STRISCE LARGHE

120 GIALLA

B4

CS101

R

150 DIA

150 TYP

C3

ACCESSIBLE SYMBOL/SIMBOLO ACCESSIBILITA'

NO SCALE / NON IN SCALA

CENTER SYMBOL BETWEEN

PARKING STRIPES/ CENTRO

DEL SIMBOLO TRA LE

STRISCE DEL PARCHEGGIO

A4

ACCESSIBLE RAMP DETAILS

NON IN SCALA

NO SCALE

PARTICOLARE RAMPA ACCESSIBILITA'

A5

SPEED TABLE DETAIL

NON IN SCALA

NO SCALE

PARTICOLARE RAMPA ACCESSIBILITA'

TOP OF FINISH GRADE /

SOMMITA' LIVELLO FINITO

TOP OF TABLE / PARTE SUPERIORE

DEL PIANO

ASPHALT BINDER COURSE INCREASED IN THICKNESS /

STRATO DI LEGANTE D'ASFALTO AUMENTATO IN SPESSORE

50 ASPHALT SURFACE COURSE /

50 STRATO SUPERFICIE ASFALTATA

ASPHALT BASE LAYER /

STRATO DI BASE IN ASFALTO

FINISH PAVEMENT/

PAVIMENTO FINITO

COMPACTED SUBGRADE/

SOTTOFONDO COMPATTATO

FACE OF CURB/

FACCIA DEL CORDOLO

1 800 1 800 RAMP FLOOR

/ 1 800 RAMPA

1 800

M

I N

1 800

1 200 (UNO)

1 800

RAMP - TYPE "B" / RAMPA TIPO "B"

RAMP - TYPE "A" / RAMPA TIPO "A"

PLAN

PIANTA

SECTION/

SEZIONE

PLAN

PIANTA

SECTION/

SEZIONE

FACE OF CURB/

FACCIA DEL CORDOLO

MAX SLOPE 8% /

PENDENZA MAX 8%

MAX SLOPE 8% /

PENDENZA MAX. 8%

M A

X

S

L O

E

P E

N D

E N

Z A

M

X

FINISH PAVEMENT/

PAVIMENTO FINITO

COMPACTED SUBGRADE/

SOTTOFONDO COMPATTATO

RAMP FLOOR BROOM FINISH/

PAVIMENTO RAMPA CON FINITURA

SPAZZOLATA

600 X 1200 PRECAST CONCRETE

DETECTABLE WARNING PAVERS/

600 X 1200 PAVIMENTAZIONE TATTILE

CALCESTRUZZO PREFABBRICATO

MAX SLOPE 8% /

PENDENZA MAX 8%

MAX SLOPE 8% /

PENDENZA MAX. 8%

M A

X

S

L O

P E

N D

E N

X

IMPERVIOUS CONCRETE PAVERS, SEE

DETAIL A2 SHEET LS501 / MASSELLI

CEMENTIZI IMPERMEABILI, VEDI

DETTAGLIO A2 SU TAVOLA LS501

IMPERVIOUS CONCRETE PAVERS, SEE

DETAIL A2 SHEET LS501 / MASSELLI

CEMENTIZI IMPERMEABILI, VEDI

DETTAGLIO A2 SU TAVOLA LS501

RAMP FLOOR BROOM FINISH/

PAVIMENTO RAMPA CON FINITURA

SPAZZOLATA

600 X 1200 PRECAST CONCRETE

DETECTABLE WARNING PAVERS/

600 X 1200 PAVIMENTAZIONE TATTILE

CALCESTRUZZO PREFABBRICATO

B1

C-502

B4

CS101

B4

CS101

B2

CS102

SEE SHEET CP701 FOR

VERTICAL SIGN /

VEDERE TAVOLA CP701 PER

IL SEGNALE VERTICALE

NOTE/NOTA:

ROAD MARKING MUST BE IN ACCORDANCE WITH NUOVO CODICE DELLA STRADA. /

MARCATURA DI PAVIMENTAZIONE DEVONO ESSERE CONFORMI AL NUOVO CODICE DELLA STRADA.

120 WIDE YELLOW

STRIPE / STRISCE

LARGHE 100

BIANCHE

150 (VARIES) SEE PLAN /

150 (VARIABILE) VEDI PIANTA

S E

E

D

T

F O

R

T

Y

Y

E R

V

E D

E R

E

D E

T T

A G

L I O

P E

R

T

I P

O

D

I

S T

R A

T I G

R A

F I A

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

C-502

SECTION / SEZIONE

CORROSION RESISTANT MATERIAL

MATERIALE ANTI-CORROSIVO

#13 REINFORCING BAR /

#13 BARRA DI RINFORZO

N

X

E

R

S

W

D

H

R

G

H

E

Z

S

T

T

A

N

NOTES / NOTE:

1. VERT SP - 400 C TO C. / VERT SP - 400 C A C.

2. STEPS TO PROTRUDE 125 FROM FACE OF STRUCTURE WALL. / I GRADINI DEVONO

SPORGERE DI 125 DALLA FACCIA DEL MURA DELLA STRUTTURA.

3. PORTION OF AL STEP EMBEDDED IN CONC SHALL BE COATED W/ AN ASPHALT COATING. /

LA PARTE DI TUTTI GRADINI INCORPORATI NEL CALCESTRUZZO DEVE ESSERE RIVESTITA

CON UN RIVESTIMENTO D'ASFALTO.

ENCAPSULATED STEEL STEP / GRADINO IN ACCIAIO INCAPSULATO

BB

MACH

A A

25 25

125600125

38 SQ X 9 DEEP /

QUADRATO LARGO

38 PER 9 DI

MACH (TYP)

SECTION A-A / SEZIONE A-A

COVER - BOTTOM VIEW /

VISTA INFERIORE - COPERCHIO

70X38 SLOTS UNLESS SPECIFIED OTHERWISE /

FESSURE 70X38 SE NON DIVERSAMENTE SPECIFICATO

COVER - TOP VIEW /

VISTA SUPERIORE - COPERCHIO

MINIMUM WEIGHT CAST IRON FRAME 225 LBS. COVER 125 LBS. /

ALTEZZA MINIMA TELAIO IN FERRO BATTUTO 225 LBS. COPERCHIO 125 LBS.

SECTION B-B / SEZIONE B-B

FRAME / TELAIO

PLAN / PIANTA

NOTE / NOTA:

SEE SPECIFICATIONS FOR IDENTIFICATION MARKINGS TO BE

CAST IN TOP OF COVER. MARKINGS TO BE RAISED 10. /

VEDERE LE SPECIFICHE PER LE MARCATURE DI

IDENTIFICAZIONE CHE DEVONO ESSERE FUSE NELLA PARTE

SUPERIORE DEL COPERCHIO. MARCATURE DA SOLLEVARE DI 10.

A1

CLEANOUT/POZZETTO DI ISPEZIONE

NO SCALE / NON IN SCALA

A2

DROP INLET/INGRESSO BASSO

NO SCALE / NON IN SCALA

A4

GRAVITY SEWER WYE CONNECTION/CONNESSIONE AD Y A GRAVITA'

NO SCALE / NON IN SCALA

C2

MANHOLE STEP/GRADINO POZZETTO

NO SCALE / NON IN SCALA

CONCRETE / CALCESTRUZZO

WYE / RACCORDO A Y

100 MIN

100100

V A

R I E

S

V

A R

I A

B I L

E

CAST IRON CLEANOUT COVER

AND PLUG / TUBO DI SCARICO

IN GHISA CON COPERCHIO

FINISHED GRADE /

PIANO FINITO

M

I N

450 SQUARE

QUADRATO LARGO 450

CONCRETE /

CALCESTRUZZO

SIZE AS INDICATED /

MISURA COME INDICATO

TOP OF BELL /

SOMMITA'

POZZETTO

CONCRETE BLOCK MIN WIDTH OD +300 /

BLOCCO IN CLACESTRUZZO LARGHEZZA OD +300

PLUG IF AT END OF LINE /

TAPPARE SE ALLA FINE DELLA

LINEA DI CONDOTTA

S

Q

D

D

C

C

COLLAR DETAIL / DETAGLIO COLLARE

13X38X100

SECTION D-D / SEZIONE D-D

SECTION C-C / SEZIONE C-C

SECTION B-B / SEZIONE B-B

BB

150 (TYP)

V A

R I E

S

V

A R

I A

B I L

E

PROFILE / PROFILO

#13@100 EACH WAY /

#13@100 CIASCUNO

MODO

#13 DIAGONAL @ ALL CORNERS TYP

#13 DIAGONALE SU TUTTI GLI

ANGOLI TIPICO

WHEN INDICATED

SHAPE INVERT IN /

QUANDO INDICATO,

INVERTIRE FORMA

VERSO L'INTERNO

PRECAST

BASE

UNIT

200 BEDDING MATERIAL /

200 MATERIALE DI POSA

25 CLR TYP

125 FOR 1200 DIAMETER

150 FOR 1800 DIAMETER /

125 PER 1200 DIAMETRO

150 PER 1800 DIAMETRO

A

D

S

U

I T

S

A

S

N

E E

D E

D

A

G G

I U

N G

E R

E

U

N I T

A

D

I

R

I S

A L

I T

A

S E

C O

N D

O

N

E C

E S

S I T

A

LUGS CAST W/ COLLAR /

ALETTE FUSE CON COLLARE

CI COLLAR /

COLLARE IN

GHISA

MIN WEIGHT / PESO MINIMO:

COLLAR & LUGS / COLLARE E ALETTA: 63 LB

GRATE/GRATA: 354 LB

PRECAST TOP UNIT /

UNITÀ SUPERIORE PREFABBRICATA

LONG RADIUS BEND /

CURVATURA A LUNGO

RAGGIO

BEDDING MATERIAL /

MATERIALE LETTO DI POSA

LATERAL PIPE /

TUBO LATERALE

SUITABLE BACKFILL MATERIAL /

MATERIALE DI RIEMPIMENTO

ADATTO

45° BEND /

CURVATURA

75 MIN

CONCRETE /

CALCESTRUZZO

WYE BRANCH

/RAMO RACCORDO

TUBO A Y

MAIN

/PRINCIPALE

BEDDING MATERIAL

/ MATERIALE LETTO DI POSA

200 MIN

75 MIN 75 MIN

CONCRETE /

CALCESTRUZZO

FLOW /

FLUSSO

SUITABLE BACKFILL MATERIAL/

MATERIALE DI RIEMPIMENTO ADATTO

MAIN /

TUBAZIONE

PRINCIPALE

BEDDING MATERIAL FULL LENGTH OF WYE

/ MATERIALE DI POSA PER TUTTA LA

LUNGHEZZA DEL RACCORDO TUBO A Y

45° BEND / CURVATURA A 45°

LATERAL PIPE /

TUBO LATERALE

VERT ANGLE 45° MAX /

ANGOLO VERTICALE 45° MAX

WYE BRANCH / RAMO

RACCORDO TUBO A Y

BEDDING MATERIAL / MATERIALE LETTO

WHERE VERT ANGLE EXCEEDS 45°, CONN

SHALL BE CONC ENCASED. / DOVE L'ANGOLO

VERTICALE SUPERA I 45°, IL CONNETTORE

DEVE ESSERE INCASSATO NEL CALCESTRUZZO

STANDARD CONNECTION VERTICAL

ANGLE 45° MAX. / CONNESSIONE

STANDARD ANGOLO VERTICALE 45°MAX

VERTICAL CONNECTION / CONNESSIONE VERTICALE

C4

MANHOLE FRAME AND COVER

NON IN SCALA

NO SCALE

TELAIO E COPERCHIO POZZETTO

B2

CU101D

V A

R I E

S

V A

R

N

1200 (MIN UNO, NOTE 2) /

1200 (MIN UNO, NOTA 2)

600 DIA, MIN

NOTE / NOTA:

1. PROVIDE REINFORCEMENT AS DESIGNED BY MANUFACTURER. / FORNIRE RINFORZO COME PROGETTATO DAL

PRODUTTORE.

2. PROVIDE MANHOLE DIAMETER AS REQUIRED BY PRECAST MANUFACTURER TO ACCOMMODATE PIPING. /

FORNIRE IL DIAMETRO DEI POZZETTI COME RICHIESTO DAL PRODUTTORE PREFABBRICATO PER ALLOGGIARE

LE TUBAZIONI.

3. PROVIDE PRECAST MANHOLE FOR D400 LOADING, UNO. / FORNISCONO PASSO PRECAST PER IL

CARICAMENTO D400, UNO.

4. REINFORCEMENT ACCORDING TO PRECAST MANUFACTURER (REINFORCEMENT NOT SHOWN). / RINFORZO

SECONDO PRODUTTORE PREFABBRICATO (RINFORZO NON MOSTRATO).

5. PIPE PENETRATIONS MUST BE FRAMED BY THE PRECAST MANUFACTURER OR CORE DRILLED IN THE FIELD. /

LE PENETRAZIONI DEI TUBI DEVONO ESSERE INCORPORATE DAL FABBRICANTE PRECAST O FORATE NEL

CAMPO.

6. WATER TABLE IS SHALLOW. PROVIDE MANUFACTURER CALCULATED BUOYANCY ANALYSIS FOR ALL BELOW

GRADE STRUCTURES. STRUCTURES MUST BE SUFFICIENTLY ANCHORED TO PREVENT FLOATATION. / LA

TABELLA DELLACQUA E BASSA. FORNIRE UNANALISI DI GALLEGGIAMENTO CALCOLATA AL PRODUTTORE PER

TUTTE LE STRUTTURE DI GRADO INFERIORE. LE STRUTTURE DEVONO ESSERE ANCORATE

SUFFICIENTEMENTE PER EVITARE IL GALLEGGIAMENTO.

MH FRAME & COVER /

TELAIO E COPERCHIO CHIUSINO

GROUT IN PLACE (USE 89

AHR BOLTS TO BOLT IN

PLACE FOR WATERTIGHT

MH COVERS) / RIEMPIRE A

POSTO (UTILIZZARE 89

BULLONI AHR DA ESTRARRE

IN POSIZIONE PER

COPERTURE MH STAGNE)

TAPER SECTION /

SEZIONE CONICA

S P

A C

E R

S

D I S

T A

N Z

I A

L I

RISER SECTION /

SEZIONE DI

ALZATA

V A

R I E

S

V A

R I A

V A

R I E

S

V A

R I A

BASE SECTION /

SEZIONE DI BASE

SHAPE INVERT /

FORMARE IL

INVERTITO

150 (TYP)

200 BEDDING MATERIAL /

200 MATERIALE DA LETTO

C1

PRECAST STORM/SANITARY MANHOLE NO SCALE / NON IN SCALA

POZZETTO PLUVIALE/SANITARIO PREFABBRICATO

A2

CU101S

C1

C-503

C1

C-503

D4

CU106D

A1

CU101S

V

A

R

I

A

R

A

B

I

L

E

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

C-503

NOTES/ NOTE:

1. PROVIDE RECESS ACCESS FRAME AND COVER PER LANDSCAPE DETAILS WHEN STRUCTURE OCCURS IN PAVER AREAS. /

FORNITURA E POSA IN OPERA DI TELAIO E COPERCHIO INCASSATO PER SISTEMAZIONE A VERDE QUANDO I POZZETTI

SONO IN AREE PAVIMENTATE

2. BACKFILL MATERIAL SHALL BE CRUSHED STONE MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED BY

ASTM D2321. / IL MATERIALE DI RIEMPIMENTO DOVRA' SODDISFARE I REQUISITI DEI MATERIALI DI CLASSE II DEFINITI DA

ASTM D2321

3. BEDDING AND BACKFILL SHALL BE PLACED AND COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. /

RINTERRO E COSTIPAMENTO DOVRANNO ESSERE POSATI E COMPATTATI UNIFORMEMENTE IN ACCORDO CON ASTM D2321

4. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212. / LA RESISTENZA DELLA

CONNESSIONE DEI DRENAGGI DOVRA' ESSERE CONFORME A ASTM D3212

5. DETAIL SHOWS TYPICAL DRAIN BASIN CONFIGURATION. REFER TO MANUFACTURER FOR INLINE DRAIN CONFIGURATIONS

AND REQUIREMENTS. SUBMIT DRAIN BASIN PRODUCT DATA FOR ACCEPTANCE. / I PARTICOLARI TIPICI DEI POZZETTI DI

DRENAGGIO. FANNO RIFERIMENTO ALLA PRODUZIONE DELLA DITTA INLINE DRENAGGI, CONFIGURAZIONI E REQUISIT.

INVIARE I DATI DEL PRODOTTO DEL BACINO DI SCARICO PER L'ACCETTAZIONE.

6. SEE CU600-SERIES SHEETS FOR STRUCTURE TABLE. SMALLER DIAMETER RISERS ARE PERMISSIBLE WHERE

CONNECTING PIPE DIAMETERS ALLOW./ VEDERE TAVOLE SERIE CU-600 PER LE TAVOLE STRUTTURALI. SONO AMMESSE

ALZATE DI DIAMETRO INFERIORE SE I DIAMETRI DEL TUBO DI RACCORDO CONSENTONO

IN LOADBEARING AREAS (FIRE LANES AND PAVED SURFACES) PROVIDE RECESSED CONCRETE COLLAR

AS SHOWN. FOR PAVER AREAS: PROVIDE RECESSED ACCESS COVER (SEE LANDSCAPE DETAILS). /

NELLE AREE DI CARICO PESANTE (CORSIA VVF E AREE PAVIMENTATE) PREVEDERE COLLARI INCASSATI

IN CLS COME INDICATO. PER AREE PAVER: FORNIRE UN COPERCHIO DI ACCESSO INCASSO (VEDI

DETTAGLI DEL PAESAGGIO).

SEE LANDSCAPE FOR MATERIAL INFORMATION AND DETAILS/ VEDERE SISTEMAZIONE A VERDE

PER INFORMAZIONI SUI MATERAILI E PARTICOLARI

INJECTION MOLDED

WATER-TIGHT TEE/

INNESTO STAMPATO A "T"

RESISTETE ALL'ACQUA

INSERT INJECTION MOLDED,

GASKETED SPIGOT BY

BELL REDUCER/

INSERTO STAMPATO AD INIEZIONE,

GUARNIZIONE SPIGOT E RIDUTTORE A CAMPANA

FINISH GRADE/TERRENO FINITO

DRAINAGE SYSTEM/

SISTEMA DI DRENAGGIO

DOWNSPOUT CONNECTION FROM

DOWNSPOUT BOOT TO DRAINAGE

SYSTEM (SEE NOTES)/

CONNESSIONE AL PARASPRUZZI AL

SISTEMA DI DRENAGGIO (VEDERE

NOTA)

NOTES:

1. FOR DOWNSPOUT CONNECTIONS (UNO): /

PER LE CONNESSIONE AL PARASPRUZZI

MINIMUM SIZE = 150mm / DIM. MINIMA =150MM

MINIMUM SLOPE = 1% / PENDENZA MIN. =1%

MATERIAL = PVC / MATERIALE = PVC

MINIMUM COVER: 600mm (TRAFFIC AREAS), 300mm (YARD AREAS)/

COPERTURA MIN.: 600MM (AREA CON TRAFFICO), 300MM (CORTILI)

2. SEE PLUMBING AND ARCHITECTURAL SHEETS FOR ROOF DOWNSPOUT LOCATION,

SIZE, AND CONTINUATION. / VEDERE TAVOLE IMPIANTO IDRICO-SANITARIO E

ARCHITETTONICHE PER LA POSIZIONE, LA DIMENSIONE E LA CONTINUAZIONE DEL

PARASPRUZZI

M

P

T H

S

T

E S

P R

O F

O N

D I T

A

M

I N

V

E D

E R

E

N

O T

A

FINISH GRADE IN NON-LOADBEARING AREAS/

TERRENO NATURALE NELLE AREE NON DI CARICO

PVC STORM DRAIN LINE/

LINEA DI DRENAGGIO IN PVC

150 SUMP/

SIFONE

V A

R I A

B L

E

D

E P

T H

S E

E

P

R O

F I L

E S

INTEGRATED DUCTILE IRON FRAME AND GRATE PER ASTM A536, GRADE

70-50-05; (SEE STRUCTURE TABLE FOR RISER DIAMETER AND GRATE TYPE)/

COPERCHIO E TELAIO INTEGRATO IN GHISA ASTM A536, CLASSE 70-50-05

(VEDERE TAVOLA STRUTTURALE PER SPESSORE E TIPO DI GRIGLIA)

#57 BACKFILL MATERIAL/

MATERIALE DI RIEMPIMENTO

750 (SEE NOTES)/

(VEDERE NOTE)

100 MIN

PVC DRAIN BASIN

RISER (TYP)/

SCARICO IN PVC

INCASSATO (TIP.)

SUBGRADE, LIME STABILIZED /

300 AGGREGATE BASE/

PARTIAL SECTION A /SEZIONE PARZIALE A

L

C

450 (MIN)

SAWCUT PAVEMENT /

PAVIMENTAZIONE TAGLIATA A SEGA

150 (MIN)

EXISTING PAVEMENT SUBGRADE /

SOTTOFONDO DELLA PAVIMENTAZIONE ESISTENTE

COMPACTED SUBGRADE /

SOTTOFONDO COMPATTATO

NOTES/NOTA:

1. SEALANT AT ASPHALT PAVEMENT ISOLATION JOINT: ASTM D6690, HOT-POUR ASPHALT BASED, SELF LEVELING, AND FLUSH WITH PAVEMENT. / SIGILLANTE PER GLUNTO DI ISOLAMENTO

PAVIMENTAZIONE IN ASFALTO: ASTM D6690, BASE IN ASFALTO CALDO, LIVELLAMENTO E

COLARE CON IL PAVIMENTO

B2

PVC DRAIN BASIN/POZZETTO DI DRENAGGIO

NO SCALE

100 MIN

150 MIN

D E

P T

H

V A

R I E

S

P R

O F

O N

D I T

A

V A

R I A

B I L E

(MIN)

8%

T Y

P

8% (T

Y P

NOTES:

1. TIE BARS ARE REQUIRED BETWEEN VALLEY GUTTER AND CONCRETE PAVEMENT ONLY FOR COLD JOINTS - TIE

BARS ARE NOT REQUIRED WHEN PAVEMENT AND GUTTER ARE INTEGRALLY POURED. TIE BARS SHALL BE

ASTM A615 GRADE 60, #M13 x 600mm LONG TIE BARS, 750mm ON CENTER, AND 150mm MINIMUM FROM CONTROL

JOINTS. / I CONNETTORI SONO RICHIESTI VICINO AL TERMINALE DELLA CANALETTA ED I CONNETTORI PER I

GIUNTI FREDDI NON SONO NECESSARI QUANDO LA PAVIMENTAZIONE E LA CANALETTA SONO INTEGRATI. I

CONNETTORI DOVRANNO ESSERE SECONDO ASTM A615 SERIE 60, #M13x600MM LUNGO LE BARRE, 750MM AL

CENTRO E 150MM MINIMO PER GIUNTI DI CONTROLLO

2. COMPACT SUBGRADE AND AGGREGATE BASE TO 95% ASTM D1557 (MINIMUM)./ COMPATTARE IL FONDO E

L'AGGREGATO DI BASE AL 95% PER ASTM D 1557 (MIN)

3. PROVIDE SMOOTH RADIUS AT FLOWLINE./ FORNITURA E POSA IN OPERA DI RAGGIO LISCIO ALLA LINEA DI

FLUSSO

PVMT

500 500

COMPACTED SUBGRADE /

SOTTOFONDO COMPATTATO

30 MPa CONC (MIN)

AGGREGATE BASE /

AGGREGATO DI BASE

PVMT

M

I N

TIE BAR

(SEE NOTE 1)/

CONNETTORI

(VEDERE NOTA 1)

E Q

E Q

D

E

A

B

FC

KEY:

A. NEW ASPHALT SURFACE COURSE / NUOVO STRATO DI ASFALTO

B. NEW ASPHALT BASE COURSE / NUOVO STRATO DI BASE

C. NEW AGGREGATE BASE COURSE / NUOVO AGGREGATO DI BASE

D. EXISTING ASPHALT SURFACE COURSE / STRATO DI ASFALTO ESISTENTE

E. EXISTING ASPHALT BASE COURSE / STRATO DI BASE ESISTENTE

F. EXISTING AGGREGATE BASE COURSE / AGGREGATO DI BASE ESISTENTE

G. CONCRETE PAVEMENT ISOLATION JOINT (SEE DETAIL) /

GIUNTO DI ISOLAMENTO PAVIMENTAZIONE IN CLS /VEDERE PARTICOLARE)

H. CONCRETE VALLEY GUTTER (SEE DETAIL) / TERMINALE CANALETTA IN CLS (VEDERE

PARTICOLARE)

G

H

A2

TERMINALE CANALETTA CON PAVIMENTAZIONE ESISTENTE

NO SCALE / NON IN SCALE

A1

TERMINALE I CLS CANALETTA

NO SCALE/NON IN SCALA

1/2 ENTRACE WIDTH/

1/2LARGHEZZA ENTRATA

NOTE/NOTA:

ENTRANCE SYMMETRICAL ABOUT CENTERLINE /

ENTRATA SIMMETRICA ALLA LINEA DI ASSE

D

D

EE

F

F

FLOW LINE/DIREZIONE FLUSSO

C

C

ROADWAY/ STRADA

A3

CONCRETE ENTRANCE / ACCESSO IN CLS

NO SCALE

FOR SIDEWALK, CURB & GUTTER

BUILT INTEGRALLY

PER MARCIAPIEDI, CORDOLI E CANALETTE

COSTRUZIONE INTEGRATA

SECTION ELEVATION @ GUTTER LINE / PROSPETTO SEZIONE SULLA CANALETTA

HALF PLAN / PIANTA PARZIALE

SECTION C / SEZIONE C

SECTION F / SEZIONE F

SECTION E / SEZIONE E SECTION D / SECTION D

VARIES/ VARIABILE

CURB WIDTH /

LARGHEZZA CORDOLO

V A

R I E

S V

A R

225 300 300

G U

T T

E R

W I D

T H

L A

R G

H E

Z Z

A

C A

N A

L E

T T

A

SEE PLANS/

VEDERE PIANTA

C U

R B

W I D

T H

L A

R G

H E

Z Z

A

C O

R D

O L

O

A5

TUBO PERFORATO DRENAGGIO COPERTURA

NO SCALE/ NON IN SCALA

M

I N

D I A

TRENCH WIDTH/

LARGHEZZA SCAVO

A

C

B

KEY:

A. DRAINAGE GEOTEXTILE / TESSUTO GEOTESSILE DRANANTE

B. PERFORATED ROOF DRAIN SYSTEM PIPE, 200mm (MIN), UNO. /

SISTEMA DI DRENAGGIO CON TUBO PERFORATO 200MM (MIN)

C. OPEN-GRADED STONE: AASHTO M43 #57 /PIETRA POROSA

AASHTO M 43#57

D. TRENCH WIDTH AND BACKFILL PER SEE TRENCH DETAIL (DET C3,

SH C-510) / PER LARGHEZZA SCAVO E RIEMPIMENTO VEDERE

PARTICOLARI SCAVO (PARTICOLARE C3 SU TAV. C-C510)

E. FINISH GRADE / TERRENO NATURALE

F. MINIMUM COVER: 600mm (TRAFFIC AREAS), 300mm (YARD

AREAS) /COPRTURA MINIMA: 600MM (AREA TRAFFICATE), 300MM

(AREE CORTILI)

NOTE/NOTA:

1. OVERLAP GEOTEXTILE 300 (MIN) OR AS RECOMMENDED BY

MANUFACTURER, WHICHEVER IS GREATER. /

LA SOVRAPPOSIZIONE MINIMA DEL TESSUTO GEOTESSILE E' DI

300 MIN. RACCOMANDATA DAL PRODUTTORE, ACCETTABILI DIM.

MAGGIORI

D

E

M I N

I M

U M

C O

V E

R

C O

P E

R T

U R

A

M I N

I M

A

F

200 THICK

CONCRETE

#13 @ 300 EACH WAY

M

I N

CONCRETE TURN DOWN, ALL EDGES /

RIBASSAMENTO DEL CALCESTRUZZO, SU

TUTTI I BORDI

PLAN /PIANTA

C4

DUMPSTER PAD/ BASAMENTO CASSONETTI

NO SCALE/NON IN SCALA

C1

ROOF DOWNSPOUT CONNECTION

NON IN SCALA

NO SCALE

CONNESSIONE AL PARASPUZZI DEL TETTO

INJECTION MOLDED

WATER-TIGHT TEE (TYP)/

INNESTO STAMPATO A "T"

RESISTETE ALL'ACQUA (TIP)

PVC STORM DRAIN LINE/

LINEA DI DRENAGGIO IN PVC

P R

O F

O N

D I T

A

V

A R

I A

B I L

E

V E

D E

O

F I L

I

1/2" PREMOLDED EJ FILLER/

" GIUNTO DI ESPANSIONE

PREFORMATO

1/2" PREMOLDED EJ FILLER/

" GIUNTO DI ESPANSIONE

PREFORMATO

STRATO DI BASE AGGREGATO

SOTTOFONDO, STABILIZZAZIONE DELLA CALCE

PERFORATED ROOF DRAIN

VALLEY GUTTER TRANSITION @ EXISTING PAVEMENT

CONCRETE VALLEY GUTTER

FLUSH WITH VALLEY GUTTER, SEE DETAIL A1/C-504

A FILO CON LA GRONDAIA, VEDI DETTAGLIO A1/C-504

PROVIDE CONTRACTION

JOINTS AT 3m OC (MAX) /

PREVEDERE GIUNTI DI

CONTRAZIONE AL CENTRO

OGNI 3 M (MAX)

WASTE CONTAINTERS (BY OTHERS).

QUANTITY OF CONTAINERS MAY VARY /

CONTENITORI RIFIUTI (FUORI CONTRATTO).

LA QUANTITA DI CONTENITORI PUO VARIARE

TURN DOWN CURB/

CORDOLO RIBASSATO

Y P

A

A

B2

CU101D

B2

CU101D

B1

CS102

A3

CS101

D4

CS103

A2

CU101D

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

C-504

I N

E Q

I N

E Q

B1

RECINZIONE DI SICUREZZA

NO SCALE/NON IN SCALA

IMPACT CABLES/

CAVI D'IMPATTO

CHAIN-LINK SECURITY FENCE

NOTE: PROVIDE SIGNS AT CORNERS AND AT EVERY 30m (MINIMUM) ALONG FENCE.

SIGNAGE STYLE MUST MATCH "RESTRICTED AREA" STYLE IN "AR 190-13", CHAPTER 6-7

AND YELLOW ITALIAN RESTRICTED AREA SIGNAGE. /

NOTA: FORNIRE SEGNALI AGLI ANGOLI E A OGNI 30 m (MINIMO) RECINTO. LO STILE DI

SEGNALAZIONE DEVE CORRISPONDERE ALL'AREA "AREA RISERVATA" LO STILE DI "AR

190-13", CAPITOLO 6-7 E IL SEGNALE DELL'AREA ITALIANA RISERVATA SULLA ZONA.

PRIVACY SCREEN (TYPICAL) /

SCHERMO VERDE (TIPICO)

PRIVACY SCREEN (TYPICAL) /

SCHERMO VERDE (TIPICO)

2400 (3000 MAX)

400 DIA

2400 (3000 MAX)

FRONT ELEVATION

SIDE ELEVATION

LINE POST/

MONTANTE DI LINEA

CONTINUOUS TOP RAIL/

TUBO SUPERIOIRE CONTINUO

MIDDLE RAIL/

MONTANTE CENTRALE

CORNER OR

TERMINAL POST/

PALO D'ANGOLO

O TERMINALE

TRUSS ROD & TIGHTENER/

BARRA CON TENDITORE

CONC MOWING STRIP SEE DETAIL THIS

SHEET/

FONDAZIONE IN CLS CONTINUA (VEDI

PARTIC. SU QUESTA TAV.)

2" MESH FENCE FABRIC

RETE METALLICA

CONTINUOUS BOTTOM RAIL

SECURE TO CONC MOWING STRIP

SEE DETAIL THIS SHEET /

BARRA CONTINUA DI SICUREZZA

SOPRA LA LINEA DELLA

FONDAZIONE CONTINUA

TYPICAL CORNER OR

TERMINAL POST FOOTING/

FONDAZIONE TIPICA PALO

D'ANGOLO O TERMINALE

TYPICAL LINE POST FOOTING/

FONDAZIONE TIPICA PALO

19 ROUND BY 2400 LONG

COPPER CLAD GROUND ROD/

CORDA DI RAME NUDA PER

MESSA A TERRA 19 DIAM. PER

2400 LUNGHEZZA

#19AWG SOLID COPPER WIRE/

CAVO DI RAME RIGIDO

FINISHED GRADE/

TERRENO FINITO

NOTE / NOTA :

MOWING STRIP TO BE INSTALLED ONLY IN AREAS WHERE FENCE BORDERS

GRASS AREAS. / LA FONDAZIONE CONTINUA DOVRA' ESSERE INSTALLATA NELLE

AREE DOVE LA RECINZIONE DELIMITA LE AREE A PRATO.

PROVIDE PRIVACY SCREEN AND MESH FENCE FABRIC ON PUBLIC SIDE OF FENCE.

PROVIDE SUPPORTING RAILS AND RODS ON SECURE SIDE OF FENCE. / FORNIRE

SCHERMO VERDE E RETE METALLICA SUL LATO PUBBLICO DEL RECINTO. FORNIRE

BINARI E ASTE DI SOSTEGNO SUL LATO SICURO DELLA RECINZIONE.

BRACE RAIL/

CORRENTE DI

RINFORZO

2" MESH FENCE FABRIC

RETE METALLICA

CONTINUOUS TOP RAIL/

TUBO SUPERIOIRE CONTINUO

LINE POST/

MONTANTE DI LINEA

CONC MOWING STRIP SEE DETAIL THIS

SHEET/

FONDAZIONE IN CLS CONTINUA (VEDI

PARTIC. SU QUESTA TAV.)

VISTA FRONTALE VISTA LATERALE

BOTTOM RAIL / BARRA INFERIORE

ANCHOR BOTTOM RAIL IN CONCRETE.

SEE DETAIL THIS SHEET /

ANCORARE LA GUIDA INFERIORE NEL

CALCESTRUZZO. VEDI DETTAGLIO

QUESTA TAVOLA

FINISHED GRADE

/ LIVELLO FINITO

25 SLOPE /

PENDENZA 25

FENCE POST / PALO

RECINZIONE

FINISHED GRADE

/ LIVELLO FINITO

900 MOWING STRIP / 900

STRISCIA DI SFALCIO

CONC REINFORCED W/ 150x150 W53xW53

WWF AT MIDPOINT OF SLAB /

CALCESTRUZZO RINFORZATO CON

150X100 E W53XW53 MAGLIA METALLICA

AL CENTRO DELLA SOLETTA

FENCE POST FOUNDATION /

FONDAZIONE PALO RECINZIONE

#19 GA. STEEL WIRE / #19

DIAMETRO FILO DI FERRO

PRE-SHAPED TIE WITH

TWISTED END / NODO

PRESAGOMATO CON

OCCHIELLO

TRUSS ROD 9

MIN. / ASTA DEL

TIRANTE 9 MIN

CONC FOOTING /

BASAMENTO IN

CALCESTRUZZO

STRETCHER BAR TO ENGAGE EACH FABRIC LINK /

BARRA TENDITRICE PER AGGANCIARE OGNI RETE

FABRIC / RETE

COILED SPRING WIRE FOR STRETCHING /

FILO A MOLLA ARROTOLATO PER L'ALLUNGAMENTO

STRETCHER BAR BAND TO BE 150 MAX.

FROM TOP & BOT & SPACED @ 350 OC

MAX. / BARRA PER L'ALLUNGAMENTO

DEVE ESSERE 150 MAX DALL'ALTO AL

BASSO E DISTANZIATA IN ASSE

CENTRALE DI 350 MAX

STRETCHER BAR /

BARRA PER L'ALLUNGAMENTO

CARRIAGE BOLT /

BULLONE CARROZZA

TIE WIRE AS SPECIFIED @ 300 O.C.

MAX. / ALLACCIO FILO COME

SPECIFICATO OGNI 300 MAX

TIE TO OCCUR ON SECURE SIDE OF FENCE. / LEGATURA

SUL LATO SICURO DELLA RECINZIONE

FABRIC

/ RETE

3 THICK x 25 WIDE x 450 LONG FLAT GALV. STEEL

STRAP ANCHOR BENT TO SHAPE AS INDICATED.

INSTALL @ 1/3 POINTS BETWEEN FENCE POSTS /

3 SPESSORE x 25 LARGHEZZA x 450 LUNGHEZZA

GALV. ACCIAIO ANCORAGGIO DELLA CINGHIA

PIEGATO IN FORMA COME INDICATO. INSTALLARE

A 1/3 DEI PUNTI TRA I PALI DELLA RECINZIONE

BOTTOM RAIL / BARRA INFERIORE

BOTTOM OF FENCE FABRIC /

BASE RETE DI RECINZIONE

CONC MOWING STRIP / FASCIA DI SFALCO IN CALCESTRUZZO

B4

FENCE FASTENING DETAILS / DETTAGLIO FISSAGGIO RECINZIONE

NO SCALE / NON IN SCALA

D5

CONC MOWING STRIP / STRISCIA DI SFALCIO IN CONC

NO SCALE / NON IN SCALA

BARBED-WIRE APRON ON

EXTENSION ARMS/

FILO SPINATO SU BRACCI

ALLUNGABILI

Y

P

Y

P

35 DEGREES/

45 DEGREES

LOCK PIN (TYP.)

BARBED WIRE (TYP.)/

FILO SPINATO (TIP)

10 PLAIN PIN RIVETED FLUSH

(TYP.)/

PERNO DI FISSAGIO RIVETTATO

A FILO (TIP)

LINE POST/ PALO DI LINEA

EXTENSION ARM DETAILS/ PARTICOLARE BRACCI ALLUNGABILI

CORNER POST/ PALO D'ANGOLO

x x x xx x x x x x x x x x x x x x x x x x

4m LEAF/ APERTURA

GATE FRAME/

DROP ROD/PALETTO

CHAIN-LINK

FABRIC

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

LATCH ASSEMBLY/

ASSEMBLAGGIO

9.5 DIA. TRUSS

RODS (TYP)

50 MIN

125 MAX

HINGES (TYP)/

SAND/GRAVEL

CONCRETE

STANDARD HINGE

GATE KEEPER

(TO HOLD GATE OPEN)

150 DIA.

P.C. CONC.

25 ID

STEEL PIPE/

A

DROP ROD FOUNDATION

LATCH ASSEMBLY

DROP ROD ASSEMBLY

A1

DOUBLE SWING GATE/CANCELLO A DUE ANTE

NO SCALE/NON IN SCALA

x x x xx x x x x

ANGOLO

10 PLAIN PIN RIVETED FLUSH (TYP.)/

PERNO DI FISSAGIO RIVETTATO A

FILO (TIP)

BARBED-WIRE APRON ON EXTENSION ARMS/

FILO SPINATO SU BRACCI ALLUNGABILI

TELAIO CANCELLO

SERRATURA

TENDITORI

RECINZIONE

METALLICA

CERNIERE (TIP)

PAVED SURFACE/

SUPERFICIE

PAVIMENTATA

13 DIA. DROP ROD

(INDUSTRY

STANDARD)/

13 DIAM. TONDINI

(INDUSTRIALE

STANDARD)

BITUMINOUS/

BITUME

TUBO IN ACCIAIO

SABBIA/GHIAIA

PIANTONE CANCELLOFONDAZIONE PALO

ASSEMBLAGGIO CHIUSURA

ASSEMBLAGGIO PALI

(PER APERTURA VECCHI CANCELLI)

B4

CS101

B4

CS101

B1

C-505

PLAN @ BANDS /

PIANTA COLLARI

TRUSS ROD & BAND /TIRANTE DI RINFORZO E COLLARE

CLAMP FOR HORIZ BRACE

ELEV TERMINAL OR GATE POST / PROSPETTO

TERMINE RECINZIONE O PALO CANCELLO

BOTTOM RAIL ANCHOR DETAIL /

DETTAGLIO ANCORAGGIO RECIZIONE

INFERIORE

LINE POST ATTACHMENTS / ATTACCO AL PALO RECINZIONE

WIRE TIES @ HORIZ BRACE / ALLACCIO

FILI AL SUPPORTO ORIZZONTALE

BRACE /

MORSETTO

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

C-505

COMPACTED SOIL/

TERRENO COMPATTATO

FLOW/ FLUSSO

1350 MIN

M

I N

CURB INLET/

CURVA DI INGRESSO

CONCRETE BLOCK/

BLOCCO IN CLS

WIRE

SCREEN/

SBARRAMENTO

GRAVEL FILTER (#3, #357 OR #5 COARSE

AGGREGATE)/

FILTRO IN GHIAIA (STRATO DI AGGREGATO

#3,#357 O #5)

RUNOFF WATER

WITH SEDIMENT

OVERFLOW/

TROPPOPIENO

FILTERED WATER/

ACQUA FILTRATA

CURB INLET/

CURVA DI INGRESSO

50X100 WOOD STUD/

50x10 FERMI IN

LEGNO

SEDIMENT/

SEDIMENTI

WIRE

SCREEN/

SBARRAMENTO

SECTION A-A

PLAN VIEW

21000

A

A

E D

G

F

E

X I S

T I N

G

R O

A D

W A

Y

P

A V

E M

E N

T

B O

R D

O

D

E L

L A

P A

V I M

E N

T A

Z I O

N E

S T

R D

A L

E

E

S I S

T E

N T

E

3000 MIN

3000 MIN

3000 MIN

150 THICK LAYER OF COARSE

AGGREGATE (SIZE #1)/

SPESS. DELLO STRATTO DI

AGGREGATO

N

3600 MIN

FILTER CLOTH/

RIVESTIMENTO FILTRANTE

75 MIN

75 MIN

PIANTA

SEZIONE A-A

B

B

PLAN

SECTION B-B

SHEET FLOW/

FLUSSO LAMINARE

50X50 MIN WOOD STAKES OR EQUIVALENT

METAL PICKETS @ 1800 OC MIN/

50x50 MIN PALI IN LEGNO O PICCHETTI

METALLICI OGNI 1800 MIN

450 MIN

100 MIN

100 MIN

SHEET FLOW

FLUSSO LAMINARE

EMBED FABRIC IN GROUND/

INTERRARE IL TESSUTO NON TESSUTO

NEL TERRENO

ATTACH FILTER FABRIC TO STAKES/

ATTACCARE IL TESSUTO ALLO

STECCATO

SEZIONE B-B

PIANTA

DROP INLET

WITH GRATE/

DRENAGGIO CON GRATA

SEDIMENT/

SEDIMENTI

WIRE SCREEN/

SCHERMATURA

FILTERED WATER/

ACQUA FILTRATA

WIRE SCREEN/SCHERMATURA

CONCRETE BLOCK/

BLOCCHI IN CLS

GRAVEL FILTER

(#3, #357 OR #5

COARSE AGGREGATE)/

FILTRO IN GHIAIA (STARTO

DI AGGREGATO)

OVERFLOW/

TROPPO PIENO

RUNOFF WATER

WITH SEDIMENT/

ACQUA DI SCARICO CON

SEDIMENTAZIONE

150 TO 300 / 150 A 300

NOTES/NOTE:

APPROXIMATELY 200 STAPLES REQUIRED PER

1200X68580 ROLL ANCHOR SLOTS, JUNCTION SLOTS &

CHECK SLOTS TO BE BURIED 150 TO 300 & VARIABLE/

CIRCA 200 GRAFFE RICHIESTE PER SLOT DI

ANCORAGGIO 1200X68580, SLOT DI GIUNZIONE E DI

CONTROLLO DA INTERRARE DA 150 A 300 & VARIABILE

ANCHOR SLOT /

SCANALATURA DI FONDO

150 TO 300 / 150 A 300

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

JUNCTION SLOT / GIUNTO

DELLA SCANALATURA

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

ANCHOR SLOT/

SCANALATURA

DI FONDO

JUNCTION SLOT/

GIUNTO DELLA

SCANALATURA

CHECK SLOT / VERIFICA

SCANALATURA

CHECK SLOT/

VERIFICA SCANALATURA

225 MAX.

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

150 TO 300

/ 150 A 300

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

TERMINAL FOLD /

PIEGA TERMINALE

LAP JOINT 50

MIN./ GIUNTO

CERNIERA 50 MIN

COMBINE THIRD ROW OF STAPLES FROM EACH

STRIP IN LAP WITH ALTERNATE SPACING/

COMBINARE LA TERZA FILA DI PUNTI DI OGNI

STRISCIA IN GIRO CON SPAZIATURA ALTERNATA

900 TO 1200 MAX.

/900 A 1200 MAX.

MAX. SPACING C-C CHECK SLOTS/ MAX.

SPAZIATURA C-C FESSURE DI CONTROLLO

30000 SLOPE 4% OR LESS 15000

SLOPE STEEPER THAN 4% / 30000

PENDENZA 4% O A MENO DI 15000

PENDENZA MAGGIORE DEL 4%

25 TO 50 / 25 A 50

150 TO 200 /

150 A 200

STAPLES FORMED FROM NO.8 STEEL WIRE 200 STAPLE MIN. LENGTH FOR SANDY SOIL. 150 STAPLE

MIN. LENGTH FOR OTHER SOIL / GRAFFE FORMATE DA N.8 FILI D'ACCIAIO, 200 GRAFFE MIN.

LUNGHEZZA PER TERRENI SABBIOSI. 150 GRAFFE MIN. LUNGHEZZA PER ALTRO TIPO DI TERRENO

A1

DIGA TEMPORANEA

NO SCALE/NON IN SCALA

B1

RECINZIONE LIMO TEMPORANEA

NO SCALE/NON IN SCALA

A2

PROTEZIONE CADITOIE

NO SCALE

A3

INGRESSO TEMPORANEO DELLA COSTRUZIONE

NO SCALE

B2

INSTALLAZIONE DEL RIVESTIMENTO DI STABILIZZAZIONE DEL TERRENO

NO SCALE

C1

PROTEZIONE GRIGLIA D'ENTRATA

NO SCALE/NON IN SCALA

A4

PROTEZIONE TEMPORANEA ALBERI

NO SCALE

GRATE INLET PROTECTION

TEMPORARY SILT FENCE

TEMPORARY DIVERSION DIKE

SOIL STABILIZATION MAT-INSTALLATION

TEMPORARY CONSTRUCTION ENTRANCE

CURB INLET PROTECTION

TEMPORARY TREE PROTECTION

B3

CC101A

A1

CC101A

A3

CC101A

A3

CC102A

A1

CC101A

PLAN VIEW STAPLING DIAGRAM JUTE MESH/

VISTA PIANTA DIAGRAMMA GRAFFATURA

MESH JUTA

VARIABLE / VARIABILE

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

C-506

IDENTIFICATION/

IDENTIFICAZIONE

APPROXIMATE

DRAINAGE AREA /

AREA DRENANTE

APPROSSIMATIVE

FIRST-FLUSH VOLUME /

VOLUME ACQUA DA TRATTARE

(MIN REQD)

MAXIMUM FIRST-FLUSH

PEAK FLOW (L/S) /

PICCO MASSIMO DI

PRIMA PIOGGIA

L = LENGTH (m/) /

LUNGHEZZA

H = WATER HEIGHT (m)

(SIDE WATER DEPTH) /

ALTEZZA ACQUA

(PROFONDITA' ACQUA LATERALE)

W = WIDTH (m) /

LARGHEZZA

Y = FREEBOARD (m) /

BORDO LIBERO q1 = ELEV q2 = ELEV q3 = ELEV q4 = ELEV

Ø = PIPE DIAMETER (mm) /

DIAMETRO TUBI

D = PIPE DIAMETER (mm) /

DIAMETRO TUBI

NOTES ABOUT STORMWATER FIRST-FLUSH TREATMENT OPERATING STATION/

NOTE SULLA STAZIONE OPERATIVA PER IL TRATTAMENTO DELL'ACQUA PIOVANA

STORMWATER FIRST-FLUSH INFLOW IN A STORAGE TANK WHERE GRIT AND SLUDGE ARE REMOVED

BY SEDIMENTION.

WHEN STORAGE IS FULL A VALVE WITH FLOAT WILL CLOSE INLET PIPE. WHEN RAIN STOPS A RAIN

SENSOR ACTIVATES A TIMER. AFTER AN ESTABLISHED TIME (24-48 HOURS) PUMP WILL START AND A

CONTINUAL FLOW WILL GO INTO THE OIL WATER SEPARATOR. IF A NEW STORM HAPPENS, RAIN

SENSOR WILL STOP THE PUMP. OIL SEPARATOR HAS INSIDE ANOTHER SLUDGE SEDIMENTATION TANK

AND A GRAVITY SEPARATOR AND COALESCENCE FILTER, FILTER HAS A CLOSING SECURITY VALVE

WITH FLOAT.

WATER TREATED FROM OIL SEPARATOR DISCHARGE INTO AN INSPECTION MANHOLE AND INTO THE

STORM DRAINAGE SYSTEM. STORAGE IS EMPTY AND STATION IS READY FOR ANOTHER CYCLE.

TREATMENT STATION SHALL PROVIDE AN OUTFALL OIL CONCENTRATION LESS THAN 5 MG/LT.

WATER TABLE IS SHALLOW. PROVIDE MANUFACTURER CALCULATED BUOYANCY ANALYSIS FOR ALL

BELOW GRADE STRUCTURES. STRUCTURES MUST BE SUFFICIENTLY ANCHORED TO PREVENT

FLOATATION. /

FLUSSO DELL'ACQUA DI STOCCAGGIO IN UN SERBATOIO DI STOCCAGGIO DOVE LA POLVERE E I

FANGHI SONO RIMOSSI DA SEDIMENTION.

QUANDO LO STOCCAGGIO È PIENO UNA VALVOLA CON GALLEGGIANTE CHIUDERÀ TUBO DI INGRESSO.

QUANDO LA PIOGGIA SI FERMA UN SENSORE DI PIOGGIA ATTIVA UN TIMER. DOPO UN TEMPO

STABILITO (24-48 ORE) SI AVVIA LA POMPA E UN FLUSSO CONTINUO ANDRÀ NEL SEPARATORE DI

ACQUA DELL'OLIO. SE SUCCEDE UNA NUOVA STORIA, LA RAIN SENSOR FERMERÀ LA POMPA.

SEPARATORE DI OLIO HA ALL'INTERNO DI UN ALTRO SERBATOIO DI SEDIMENTAZIONE FANGHI E UN

SEPARATORE DI GRAVITÀ E COALESCENZA FILTRO, FILTRO HA UNA VALVOLA DI SICUREZZA DI

CHIUSURA CON GALLEGGIANTE.

ACQUA TRATTATA DA SCARICO SEPARATORE OLIO IN UN TOMBINO ISPEZIONE E NEL SISTEMA DI

DRENAGGIO TEMPESTA. LO STOCCAGGIO È VUOTO E LA STAZIONE È PRONTA PER UN ALTRO CICLO.

LA STAZIONE DI TRATTAMENTO DEVE FORNIRE UNA CONCENTRAZIONE DI OLIO IN USCITA INFERIORE

A 5 MG/LT.

LA TABELLA DELL'ACQUA È BASSA. FORNIRE UN'ANALISI DI GALLEGGIAMENTO CALCOLATA AL

PRODUTTORE PER TUTTE LE STRUTTURE DI GRADO INFERIORE. LE STRUTTURE DEVONO ESSERE

ANCORATE SUFFICIENTEMENTE PER EVITARE IL GALLEGGIAMENTO.

A2

TRATTAMENTO ACQUE DI PRIMA PIOGGIA

NO SCALE/NON IN SCALA

SWM6 (VERONA) 10,000 m

40 m

70 L/S 5.3 m

2.0 m

3.8 m 0.9 m 30.65 m 28.59 m 28.29 m 26.29 m NA - CONFIGURATION "B" 300 mm

APPROXIMATE ELEVATIONS - SEE STORM PROFILES AND STRUCTURE TABLES /

QUOTE APPROSSIMATIVE - VEDI PROFILI TEMPORALI E TABELLE DELLA STRUTTURA

STORMWATER FIRST-FLUS TREATMENT

SWM4 (VENEZIA) 10,000 m

50 m

70 L/S 6.6 m

2.0 m

3.8 m 0.9 m 30.65 m 28.40 m 28.10 m 26.10 m NA - CONFIGURATION "B" 300 mm

SWM5 (MILANO) 13,000 m

70 m

130 L/S 9.3 m

2.0 m

3.8 m 0.9 m 30.50 m 28.66 m 28.28 m 26.28 m NA - CONFIGURATION "B" 375 mm

A1

CC101D

TO OUTFALL /

ALLO SCARICO

STORM DRAIN

(HIGH-FLOW BYPASS)

STORM DRAIN

DRENAGGIO

(FLUSSO IN ENTRATA)

STAINLESS STEEL CLOSING

VALVE WITH FLOAT/

VALVOLA DI CHIUSURA IN

ACCIAIO INOX

FLOW DIVERSION TRUCTURE/

POZZETTO DEVIAZIONE FLUSSO

OIL WATER SEPARATOR COMPLETE WITH SLUDGE SEDIMENTATION TANK, GRAVITY SEPARATOR, AND COALESCENCE

FILTER. PROVIDE CLOSING SECURITY VALVE WITH FLOAT. MAXIMUM FLOW CAPACITY = 4 L/S/OIL WATER SEPARATOR

COMPLETE WITH SLUDGE SEDIMENTATION TANK, GRAVITY SEPARATOR, AND COALESCENCE FILTER. PROVIDE

CLOSING SECURITY VALVE WITH FLOAT. MAXIMUM FLOW CAPACITY = 4 L/S / SEPARATORE ACQUA-OLIO COMPLETO DI

SERBATOIO DI SEDIMENTAZIONE DEI FANGHI, SEPARATORE A GRAVITÀ E FILTRO A COALESCENZA. FORNIRE

CHIUSURA VALVOLA DI SICUREZZA CON GALLEGGIANTE. PORTATA MASSIMA = 4 L/OLIO SEPARATORE ACQUA-OLIO

COMPLETO DI VASCA DI SEDIMENTAZIONE FANGHI, SEPARATORE A GRAVITÀ E FILTRO A COALESCENZA. FORNIRE

VALVOLA DI SICUREZZA VALVOLA DI SICUREZZA CON GALLEGGIANTE. CAPACITÀ MASSIMA DI FLUSSO = 4L/S

PLAN

TREATMENT

INFLOW/

FLUSSO D'ENTRATA

AL TRATTAMENTO

FIRST-FLUSH STORAGE TANK/

SERBATOIO DI STOCCAGGIO

ACQUA DI PRIMA PIOGGIA

HDPE PRESSURE PIPE/

TUBAZIONE PEAD IN PRESSIONE

W

B B

L

D

SEE PLAN FOR LOCATION/

VEDERE PIANTA PER POSIZIONE)

FINAL MANHOLE/

POZZETTO FINALE

O V

E R

F L

O

A

I N

T R

O P

E

L

D R

E N

A G

G I O

CONFIGURATION "A"

TO OUTFALL /

ALLO SCARICO

CONFIGURATION "B"

200 PVC PIPE

MINIMUM SLOPE = 0.5%, UNO

STORM DRAIN

(HIGH-FLOW BYPASS)/

DRENAGGIO (BYPASS DI ALTO

FLUSSO)

A

A

OIL WATER SEPARATOR (SEE CONFIGURATION "A"

FOR NOTES) / SEPARATORE DI OLI (VEDERE

CONFIGURAZIONE "A" PER LE NOTE).

HDPE PRESSURE PIPE/

TUBAZIONE PEAD IN PRESSIONE

CONFIGURAZIONE "A"

CONFIGURAZIONE "B"

PIANTA

SECTION B

IP 66 CLOSET WITH COMMAND PANEL AND

TIMER CONNECTED TO RAIN SENSOR/

CHIUSURA IL66 CON PANNELLO COMMANDO E

TIMER CONNESSO AL SENSORE

TO OIL WATER SEPARATOR/

AL SEPARATORE DI OLI

SAND BACKFILL

/ LETTO DI SABBIA

LEAN

CONCRETE/

MAGRONE

SUBMERSIBLE PUMP 0.6 KW WITH CHECK

VALVE AND GATE ON FORCED LINE; DISCHARGE FLOW = 1.5 L/s/

POMPA SOMMERSA 0,6 KW CON VALVOLA DI CONTROLLO E

CHIUSURA SU LINEA FORZATA,; FLUSSO DI SCARICO =1.5l/S

H Y

800 (MIN)

HEAVY-DUTY FRAME AND COVER (TYPICAL)/

COPERCHIO E TELAIO CARRABILE (TIP.)

1.50 (MIN)

600 (MIN)

SECTION A

PRECAST REINFORCED

CONCRETE STRUCTURE/

STRUTTURA PREFABBRICATA

IN CALCESTRUZZO ARMATO

D

L q1 q2 q4

Ø

OIL WATER SEPARATOR

(OWS)/SEPARATORE DI OLI

q3

NOTE: CONFIGURATION "A" SHOWN, THIS VIEW/

NOTA: CONFIGURAZIONE "A" , MOSTRATA SU QUESTA VISTA

q3 q2

PIANTA

FLOW DIVERSION STRUCTURE/

POZZETTO DEVIAZIONE FLUSSO

SEZIONE A

STAINLESS STEEL CLOSING

VALVE WITH FLOAT/

VALVOLA DI CHIUSURA IN

ACCIAIO INOX

HDPE PRESSURE PIPE/

TUBAZIONE PEAD IN PRESSIONE

OVERFLOW STORM DRAINAGE/

DRENAGGIO DEL TROPPO PIENO

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

M

A R

K G

A R

L A

N D s t

P l o t t e d

F i l e n a m e

L D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

A

RM

Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AS NOTEDAS NOTED

AS NOTED

D E

T T

A G

L I

C

I V

I L I

C I V

I L

D

E T

A I L S

C-507

A2

POZZETTO DI PRE-TRATTAMENTO (TIPO 1)

NO SCALE / NON IN SCALA

m m

BYPASS / DERIVAZIONE

INV OUT = 300mm HIGHER THAN

BOTTOM OF INFILTRATION BASIN

(SEE PROFILES)

A3

POZZETTO DI PRE-TRATTAMENTO (TIPO 2)

NO SCALE / NON IN SCALA

NOTE/NOTA:

SEE PRECAST STORM MANHOLE DETAILS FOR ADDITIONAL REQUIREMENTS/

VEDERE PARTICOLARI DEL POZZETTO PREFABBRICATO PER REQUISITI AGGIUNTIVI .

m m

TO INFILTRATION BASIN /

AL POZZETTO DI INFILTRAZIONE

INV OUT (SEE PROFILES)

ROOF DRAIN PIPE

INV IN (SEE PROFILES)

/DRENAGGIO ACQUE

DEL TETTO (VEDERE

PROFILI)

BYPASS PIPE OUT, BEYOND WEIR WALL

DERIVAZIONE DEL TUBO IN USCITA VICINO

AL MURO DI SBARRAMENTO

WEEPHOLES TO AGGREGATE

BASE BELOW/ FORI DI DRENAGGIO

AL FONDO IN AGGREGATO

SUMP/SIFONE

INLET STRAINER /FILTRO IN

INGRESSO

WEIR WALL

TOP ELEV = 300mm

HIGHER THAN

BOTTOM OF

INFILTRATION BASIN

ROOF DRAIN PIPE

INV IN (SEE PROFILES)

/ DRENAGGIO ACQUE

DEL TETTO (VEDERE

PROFILI)

TO INFILTRATION BASIN /

AL POZZETTO DI INFILTRAZIONE

INV OUT (SEE PROFILES)

WEEPHOLES TO AGGREGATE

BASE BELOW/ FORI DI DRENAGGIO

AL FONDO IN AGGREGATO

SUMP / SIFONE

INLET STRAINER /FILTRO IN

INGRESSO

NOTE/NOTA:

SEE PRECAST STORM MANHOLE DETAILS FOR ADDITIONAL REQUIREMENTS/

VEDERE PARTICOLARI DEL POZZETTO PREFABBRICATO PER REQUISITI AGGIUNTIVI .

PRE-TREATMENT MANHOLE (TYPE 2)PRE-TREATMENT MANHOLE (TYPE 1)

8.58m m

5.6m

5.6m m

17.2m m m m m m m

18.59m m m m

300 PVC IN

INV = 29.50

300 PVC IN

INV = 29.50

P

I N

300 PVC IN

INV = 29.50

P

I N

I

M

M

M

M

M

M

M

M

M

M

M

MILANO (WEST / OVEST) MILANO (EAST / EST)

VERONA

P

I N m

C1

/ SCHEMA DEL BACINO DI INFILTRAZIONE - VENEZIA

SCALE: 1:100

INFILTRATION BASIN SCHEMATIC - VENEZIA

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET. /

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA.

VENEZIA

A1

/ SCHEMA DEL BACINO DI INFILTRAZIONE - VERONA

SCALE / SCALA: 1:100

INFILTRATION BASIN SCHEMATIC - VERONA

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET. /

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA

B2

/ SCHEMA DEL BACINO DI INFILTRAZIONE - MILANO (WEST)

SCALE: 1:100

INFILTRATION BASIN SCHEMATIC - MILANO (WEST)

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET./

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA.

B4

/ SCHEMA DEL BACINO DI INFILTRAZIONE - MILANO (EAST)

SCALE / SCALA: 1:100

INFILTRATION BASIN SCHEMATIC - MILANO (EAST)

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET. /

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA.

1. EXCAVATION SHALL EXTEND A MINIMUM OF 600mm OUTSIDE OF ALL MODULAR UNITS.

/ LO SCAVO SI ESTENDE PER UN MINIMO DI 600MM AL DI FUORI DELLE UNITA' MOBILI.

2. MODULAR UNITS ON ENDS SHALL BE TURNED 90° (NOT SHOWN IN SCHEMATIC).

/ LE UNITÀ MODULARI ALLE FINE DEVONO ESSERE RUOTATE DI 90° (NON INDICATE NELLO

SCHEMA).

3. THE SCHEMATIC LAYOUT DESIGN USES THE FOLLOWING MODULAR UNIT DATA BASED ON A

PARTICULAR MANUFACTURED MODULAR SYSTEM. OTHER MODULAR SYSTEMS ARE

ALLOWED. THE QUANTITY, CONFIGURATION, AND TOP ELEVATIONS OF MODULAR UNITS

MAY VARY SLIGHTLY BASED ON THE ACTURAL SYSTEM USED. COORDINATE UNIT

LOCATIONS WITH SITE FEATURES AND UNDERGROUND UTILITIES. SUBMIT PRODUCT DATA

AND SHOP DRAWINGS FOR ACCEPTANCE.

/ IL LAYOUT SCHEMATICO UTILIZZA I SEGUENTI DATI UNITARI MODULARI BASATI SU UN

PARTICOLARE SISTEMA MODULARE PRODOTTO. ALTRI SISTEMI MODULARI SONO AMMESSI.

LA QUANTITÀ, LA CONFIGURAZIONE E LE ELEVAZIONI SUPERIORI DELLE UNITÀ MODULARI

POSSONO VARIARE LEGGERMENTE IN BASE AL SISTEMA ATTUALE UTILIZZATO.

COORDINATE I LUOGHI UNITARI CON LE CARATTERISTICHE DEL SITO E LE UTILITÀ

SOTTOGRUPPO. PRESENTA DATI PRODOTTO E DISEGNI NEGOZIO PER L'ACCETTAZIONE

MODULAR UNIT DATA /DATI DELL'UNITA' MODULARE :

3.1. STYLE: SINGLE / STILE : SINGOLO

3.2. DIMENSIONS: WIDTH = 400mm, LENGTH = 715mm, HEIGHT = 440mm / DIMENSIONI

LARGHEZZA = 400mm, LUNGHEZZA = 715mm, ALTEZZA = 440mm

3.3. MODULAR UNIT CAPACITY: 125 LITERS / CAPACITA' DELL'UNITA' MODULARE: 125 LITRI

4. INSTALLATION MUST BE PERFORMED BY A MANUFACTURER-CERTIFIED INSTALLER.

/L'INSTALLAZIONE DEVE ESSERE EFFETTUATA DA UN IMPIANTO CERTIFICATO DAL

FABBRICANTE

= APPROXIMATE LOCATION OF MAINTENANCE PORT. SEE DETAIL A1/C-509. COORDINATE

PORT LOCATION WITH SITE FEATURES AND UNDERGROUND UTILITIES./ APPROSSIMATIVA

POSIZIONAMENTO DEL LOCALE DI MANNUTENZIONE . VEDERE DETTAGLIO A1/C-509.

COORDINATE LA POSIZIONE DEL POSTO CON LE CARATTERISTICHE DEL SITO E LE UTILITÀ

IN SOTTOGRUPPO.

/ NOTE GENERALI PER IL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .