Attachment I - 1632846dwg18of24.pdf
PDF 29 MB Posted
- Solicitation number
- N62470-21-R-0015
About this file
This document provides details on a federal solicitation for construction services. The solicitation number is N62470-21-R-0015 and seeks offers for Phase 2 of the Family Housing Villaggio at Vicenza, Italy project. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Offerors should review the attached solicitation for full requirements related to the construction of additional family housing units at the Villaggio site in Vicenza. Responses are due based on the date specified within the solicitation. This project aims to increase family housing capacity to support military personnel stationed in Vicenza, Italy.
View the file
Other files
Show 40 more
Latest 50 of 66 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2 5 9 12 14
I
G
H
J
A008
MASTER BEDROOM
A007
BEDROOM 3
A006
BEDROOM 2
A005
LIVING ROOM
A015
BALCONY
A004
KITCHEN
A003
DINING
A002
FAMILY
A001
FOYER
A013
STORAGE
A012
LAUNDRY
A011
BATHROOM 2
A010
MASTER BATHROOM
A009
MASTER CLOSET
A014
CIRCULATION
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
FLT-10*
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :5
AF ACGMCG
3B R
A P
A R
TM
E
N T
G R
O U
N D
F
LO
O R
F
IN
IS
H
P
LA
N 3B
R A
P P
A R
TA
M
E N
TO
P
IA
N
TA
F
IN
IT
U R
E P
IA
N
O T
E R
R A
IN101
14092488
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
3BR APARTMENT GROUND FLOOR FINISH PLAN /
3BR APPARTAMENTO PIANTA FINITURE PIANO TERRA
DCBA
E202
DINING
E201
FOYER
E212
FAMILY
E211
LAUNDRY
E210
BATHROOM 2
E209
MASTER BATHROOM
E207
MASTER BEDROOM
E208
MASTER CLOSET
E206
BEDROOM 2
E205
BEDROOM 3
E204
LIVING ROOM
E214
CIRCULATION
E215
BALCONY
E213
STORAGE
E203
KITCHEN
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
FLT-10*
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :1
AF ACGMCG
3B R
A P
A R
TM
E
N T
TY
P
IC
A
L
FL
O O
R F
IN
IS
H P
LA
N
3B R
A P
P A
R
TA
M E
N
TO
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T
IP
IC
O
IN102
14092489
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
3BR APARTMENT TYPICAL FLOOR FINISH PLAN /
3BR APPARTAMENTO PIANTA FINITURE PIANO TIPICO
DCBA
B106
BEDROOM 2
B105
BEDROOM 3
B104
LIVING ROOM
B102
DINING
B103
KITCHEN
B101
FOYER
B113
STORAGE
B112
FAMILY
B111
LAUNDRY
B110
BATHROOM 2
B109
MASTER BATHROOM
B114
CIRCULATION
B107
MASTER BEDROOM
B108
MASTER CLOSET
B115
BALCONY
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
FLT-14*
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :1
AF ACGMCG
3B R
A P
A R
TM
E
N T
FI
R
S T
FL
O
O R
F
IN
IS
H
P
LA
N 3B
R A
P P
A R
TA
M
E N
TO
P
IA
N
TA
F
IN
IT
U R
E P
IA
N
O P
R
IM
O
IN103
14092490
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
3BR APARTMENT FIRST FLOOR FINISH PLAN /
3BR APPARTAMENTO PIANTA FINITURE PIANO PRIMO
G
H
J
A001
FOYER
A002
FAMILY
A003
DINING
A004
KITCHEN
A005
LIVING ROOMA006
BEDROOM 2A007
BEDROOM 3
A008
MASTER BEDROOM
A009
MASTER CLOSET
A010
MASTER BATHROOM A011
BATHROOM 2
A012
LAUNDRY
A013
STORAGE
A014
CIRCULATION
A015
BALCONY
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
SHT-01
FLT-10*
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:1 :1
AF ACGMCG
3B R
A P
A R
TM
E
N T
A B
A G
R O
U N
D F
LO
O
R F
IN
IS
H P
LA
N
3B R
A P
P A
R
TA
M E
N
TO
A B
A P
IA
N
TA
F
IN
IT
U R
E P
IA
N
O T
E R
R A
IN104
14092491
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
3BR APARTMENT ABA GROUND FLOOR FINISH PLAN /
3BR APPARTAMENTO ABA PIANTA FINITURE PIANO TERRA
DCBA
C101
FOYER
C102
DINING
C103
KITCHEN
C104
LIVING ROOM
C105
BEDROOM 3C106
BEDROOM 2
C107
MASTER BEDROOM
C108
MASTER CLOSET
C109
MASTER BATHROOM
C110
BATHROOM 2
C111
LAUNDRY
C112
FAMILY
C113
STORAGE
C114
CIRCULATION
C115
BALCONY
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
SHT-01
FLT-14*
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :3
AF ACGMCG
3B R
A P
A R
TM
E
N T
A B
A F
LO
O
R F
IN
IS
H P
LA
N
3B R
A P
P A
R
TA
M E
N
TO
A B
A P
IA
N
TA
F
IN
IT
U R
E
IN105
14092492
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A A .r vt
SCALE 1 : 50
A1
3BR APARTMENT ABA FLOOR FINISH PLAN /
3BR APPARTAMENTO ABA PIANTA FINITURE
G
E
H
J
4 6
G201
FOYER
G202
FAMILY
G203
LIVING ROOM
G204
KITCHEN
G216
BALCONY
G205
DINING
G206
BEDROOM 3
G207
BEDROOM 2
G208
MASTER BEDROOM
G209
MASTER CLOSET
G210
MASTER BATHROOM
G211
BEDROOM 4
G212
BATHROOM 2
G213
LAUNDRY
G214
STORAGE
G215
CIRCULATION
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
FLT-10*
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :2
AF ACGMCG
4B R
A P
A R
TM
E
N T
TY
P
IC
A
L
FL
O O
R F
IN
IS
H P
LA
N
4B R
A P
P A
R
TA
M E
N
TO
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T
IP
IC
O
IN106
14092493
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
4BR APARTMENT TYPICAL FLOOR FINISH PLAN /
4BR APPARTAMENTO PIANTA FINITURE PIANO TIPICO
G
E
H
J
4 6
D101
FOYER
D102
FAMILY
D103
LIVING ROOM
D104
KITCHEN
D116
BALCONY
D105
DINING
D106
BEDROOM 3
D107
BEDROOM 2
D108
MASTER BEDROOM
D109
MASTER CLOSET
D110
MASTER BATHROOM
D111
BEDROOM 4
D112
BATHROOM 2
D113
LAUNDRY
D114
STORAGE
D115
CIRCULATION
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-01
SHT-01
FLT-10*
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / DOVE LE PIASTRELLE SONO ESPOSTE ALLE CONDIZIONI ATMOSFERICHE
ESTERNE ALL'INGRESSO E AI BALCONI, DEVONO ESSERE RESISTENTI ALL'ACQUA E
ANTISCIVOLO
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :2
AF ACGMCG
4B R
A P
A R
TM
E
N T
A B
A F
LO
O
R F
IN
IS
H P
LA
N
4B R
A P
P A
R
TA
M E
N
TO
A B
A P
IA
N
TA
F
IN
IT
U R
E P
IA
N
O
IN107
14092494
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
4BR APARTMENT ABA FLOOR FINISH PLAN /
4BR APPARTAMENTO ABA PIANTA FINITURE PIANO
40 39 38 37 36 35 34 33 32 31
FD
E
STAIR
CORRIDOR
ELEVATOR
2 3 4 5 6 7 81
FD
E
CORRIDOR
STAIR
MECHANICAL ROOM
MECHANICAL ROOM
ELEVATOR
42 43 44 45 46 47 4841
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-11
FLF-03
FLT-04
FLF-04
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :3
AF ACGMCG
A P
B
LD
G
G R
O U
N D
A N
D T
Y P
IC
A
L
FL
O O
R F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T E
R R
A E
T
IP
IC
O
IN108
14092495
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A A .r vt
SCALE 1 : 50
A1
AP BUILDING 23400 GROUND FLOOR FINISH PLAN /
APPARTAMENTO 23400 PIANTA FINITURE PIANO TERRA
SCALE 1 : 50
A3
AP BUILDING 23400 TYPICAL FLOOR FINISH PLAN /
APPARTAMENTO 23400 PIANTA FINITURE PIANO TIPO
G
H
C
D
5 7 8 10 11 126
E
CORRIDOR
MECHANICAL ROOM
STAIR
ELEVATOR
MECHANICAL ROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-04
FLT-11
FLF-03
FLF-04
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :5
AF ACGMCG
A P
B
LD
G
G R
O U
N D
F
LO
O R
F
IN
IS
H
P
LA
N A
P E
D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U R
E P
IA
N
O T
E R
R A
IN109
14092496
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 23500 GROUND FLOOR FINISH PLAN /
APPARTAMENTO 23500 PIANTA FINITURE PIANO TERRA
G
H
C
D
7 8 10 11 126
E
CORRIDOR
STAIR
MECHANICAL ROOM
ELEVATOR
MECHANICAL ROOM
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-11
FLF-03
FLF-04
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :5
AF ACGMCG
A P
B
LD
G
T Y
P
IC
A L
FL
O
O R
F
IN
IS
H
P
LA
N A
P E
D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U R
E P
IA
N
O T
IP
IC
O
IN110
14092497
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 23500 TYPICAL FLOOR FINISH PLAN /
APPARTAMENTO 23500 PIANTA FINITURE PIANO TIPO
40393837363534333231
30 29
G
D
F
CORRIDOR
ELEVATOR
MECHANICAL ROOM
STAIR
2345678 1
MECHANICAL ROOM GD
F
MECHANICAL ROOM
MECHANICAL ROOM
ELEVATOR
STAIR
CORRIDOR
42434445464748 41
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-11
FLF-03
FLT-04
FLF-04
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH INDIVIDUAL APARTMENT
BUILDING PLANS TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO ESSERE
LETTE INSIEME ALLE PIANTE DEI SINGOLI APPARTAMENTI PER INDIVIDUARE LE
POSIZIONI ESATTE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :3
AF ACGMCG
A P
B
LD
G
G R
O U
N D
A N
D T
Y P
IC
A
L
FL
O O
R F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T E
R R
A E
T
IP
IC
O
IN111
14092498
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 23200 GROUND FLOOR FINISH PLAN /
APPARTAMENTO 23200 PIANTA FINITURE PIANO TERRA
SCALE 1 : 50
A3
AP BUILDING 23200 TYPICAL FLOOR FINISH PLAN /
APPARTAMENTO 23200 PIANTA FINITURE PIANO TIPICO
30 29
40393837363534333231
G
D
ELEVATOR
MECHANICAL ROOM
STAIR
CORRIDOR
2345678 1
MECHANICAL ROOM
GD
CORRIDOR
MECHANICAL ROOM
ELEVATOR
MECHANICAL ROOM
STAIR
42434445464748 41
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-11
FLF-03
FLT-04
FLF-04
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:1 :1
AF ACGMCG
A P
B
LD
G
G R
O U
N D
A N
D T
Y P
IC
A
L
FL
O O
R F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T E
R R
A E
T
IP
IC
O
IN112
14092499
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 26200 GROUND FLOOR FINISH PLAN /
APPARTAMENTO 26200 PIANNTA FINITURE PIANO TERRA
SCALE 1 : 50
A3
AP BUILDING 26200 TYPICAL FLOOR FINISH PLAN /
APPARTAMENTO 26200 PIANTA FINITURE PIANO TIPO
FEC D
H107
BALCONY
H105
KITCHEN
H104
DINING
H103
LIVING ROOM
H102
FAMILY
H100
CIRCULATION
H101
HALF BATH
FEC D
H000
ENTRY
H005
GARAGE
H004
STORAGE
H003
LAUNDRY
H006
FOYER
H007
CIRCULATION
H008
CLOSET
H002
MECHANICAL ROOM
H001
MAIN ENTRY
23 1
FEC D
H205
MASTER BATHROOM
H206
MASTER CLOSET
H204
MASTER BEDROOM
H203
BATHROOM 2
H200
CIRCULATION
H201
BEDROOM 3 H202
BEDROOM 2
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-03
FLT-13*
FLF-03
FLT-09*
FLF-01
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / RIFERISI
AL FOGLIO A-001 PER NOTE GENERALI, LEGENDE E SIMBOLI
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / LE PIANTE DELLE SINGOLE
UNITA' SONO RAPPRESENTATIVE DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DI FASE
2. FARE RIFERIMENTO ALLE NOTE GENERALI G-002 PER LA SPIEGAZIONE COMPLETA
DELLA SUDDIVISIONE DEGLI EDIFICI E DELL'UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / RIFERISI AL FOGLIO I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E AL FOGLIO I-601 E I-602 PER L'ABACO DELLE FINITURE
4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH THE NEIGHBORHOOD
PLANS AS002 TO AS005 TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO
ESSERE VISIONATE IN COMBINAZIONE CON LE PIANTE DI QUARTIERE DA AS002 A
AS005 PER IDENTIFICARE LE POSIZIONI ESATTE.
5. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / LE PIASTRELLE ESTERNE DEGLI INGRESSI E DEI BALCONI ESPOSTE
ALLE CONDIZIONI METEOROLOGICHE DEVONO ESSERE TRATTATE CON PRODOTTI
IMPERMEABILIZZANTI E ANTISCIVOLO
6. THE STAIR FLOOR IS FLT-03 AND THE SIZE OF THE PIECES MUST MATCH THE STEPS.
/ IL PAVIMENTO DELLE SCALE È FLT-03 E LA DIMENSIONE DEI PEZZI DEVE
CORRISPONDERE AI GRADINI.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:4 :0
AF ACGMCG
3B R
T H
G R
O U
N D
, F
IR
S T
A N
D S
E C
O N
D F
LO
O
R F
IN
IS
H P
LA
N
3B R
T H
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T E
R R
A , P
R
IM
O E
S E
C O
N D
O
IN113
14092500
M C G
V ic e n z a
A F H p h a s e
P
TH
A e n ve lo p e .r vt
SCALE 1 : 50
A2
3BR TH FIRST FLOOR FINISH PLAN /
TOWNHOUSE 3BR PIANTA FINITURE
PRIMO PIANO
SCALE 1 : 50
A1
3BR TH GROUND FLOOR FINISH PLAN /
TOWNHOUSE 3BR PIANTA FINITURE
PIANO TERRA
SCALE 1 : 50
A3
3BR TH SECOND FLOOR FINISH PLAN /
TOWNHOUSE 3BR PIANTA FINITURE
SECONDO PIANO
R S T U
I000
ENTRY
I005
GARAGE
I004
STORAGE
I002
LAUNDRY
I003
MECHANICAL ROOM
I001
MAIN ENTRY
I008
FOYER
I007
CLOSET
I006
CIRCULATION
23 1
R S T U
I107
BALCONY
I104
DINING
I103
LIVING ROOM
I102
FAMILY
I101
HALF BATH
I100
CIRCULATION
I106
PANTRY
I105
KITCHEN
R S T U
I206
BEDROOM 4
I205
MASTER BEDROOM
I207
BATHROOM 2
I200
CIRCULATION
I208
LINEN CLOSET
I203
MASTER BATHROOM
I204
MASTER CLOSET
I202
BEDROOM 2
I201
BEDROOM 3
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-03
FLT-13*
FLF-03
FLT-09*
FLF-01
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / RIFERISI
AL FOGLIO A-001 PER NOTE GENERALI, LEGENDE E SIMBOLI
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / LE PIANTE DELLE SINGOLE
UNITA' SONO RAPPRESENTATIVE DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DI FASE
2. FARE RIFERIMENTO ALLE NOTE GENERALI G-002 PER LA SPIEGAZIONE COMPLETA
DELLA SUDDIVISIONE DEGLI EDIFICI E DELL'UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / RIFERISI AL FOGLIO I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E AL FOGLIO I-601 E I-602 PER L'ABACO DELLE FINITURE
4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH THE NEIGHBORHOOD
PLANS AS002 TO AS005 TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO
ESSERE VISIONATE IN COMBINAZIONE CON LE PIANTE DI QUARTIERE DA AS002 A
AS005 PER IDENTIFICARE LE POSIZIONI ESATTE.
5. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / LE PIASTRELLE ESTERNE DEGLI INGRESSI E DEI BALCONI ESPOSTE
ALLE CONDIZIONI METEOROLOGICHE DEVONO ESSERE TRATTATE CON PRODOTTI
IMPERMEABILIZZANTI E ANTISCIVOLO
6. THE STAIR FLOOR IS FLT-03 AND THE SIZE OF THE PIECES MUST MATCH THE STEPS.
/ IL PAVIMENTO DELLE SCALE È FLT-03 E LA DIMENSIONE DEI PEZZI DEVE
CORRISPONDERE AI GRADINI.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:4 :1
AF ACGMCG
4B R
T H
G R
O U
N D
, F
IR
S T
A N
D S
E C
O N
D F
LO
O
R F
IN
IS
H P
LA
N
4B R
T H
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T E
R R
A , P
R
IM
O E
S E
C O
N D
O
IN114
14092501
M C G
V ic e n z a
A F H p h a s e
P
TH
A e n ve lo p e .r vt
SCALE 1 : 50
A1
4BR TH GROUND FLOOR FINISH PLAN /
TOWNHOUSE 4BR PIANTA FINITURE
PIANO TERRA
SCALE 1 : 50
A2
4BR TH FIRST FLOOR FINISH PLAN /
TOWNHOUSE 4BR PIANTA FINITURE
PRIMO PIANO
SCALE 1 : 50
A3
4BR TH SECOND FLOOR FINISH PLAN /
TOWNHOUSE 4BR PIANTA FINITURE
SECONDO PIANO
RQP
O
N
S
J005
GARAGE
J004
STORAGE
J006
FOYER
J007
STORAGE
J002
MECHANICAL ROOM
J003
LAUNDRY
J001
ENTRY
23 1
RQP
N
S
J105
KITCHEN
J104
DINING
J102
FAMILY
J103
LIVING ROOM
J106
HALF BATH
J101
CIRCULATION
J107
BALCONY
RQP
N
S
J202
BEDROOM 2
J203
BATHROOM 2
J201
BEDROOM 3
J200
CIRCULATION
J207
LINEN CLOSET
J204
MASTER BEDROOM
J206
MASTER CLOSET
J205
MASTER BATHROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-03
FLT-13*
FLF-03
FLT-09*
FLF-01
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / RIFERISI
AL FOGLIO A-001 PER NOTE GENERALI, LEGENDE E SIMBOLI
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / LE PIANTE DELLE SINGOLE
UNITA' SONO RAPPRESENTATIVE DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DI FASE
2. FARE RIFERIMENTO ALLE NOTE GENERALI G-002 PER LA SPIEGAZIONE COMPLETA
DELLA SUDDIVISIONE DEGLI EDIFICI E DELL'UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / RIFERISI AL FOGLIO I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E AL FOGLIO I-601 E I-602 PER L'ABACO DELLE FINITURE
4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH THE NEIGHBORHOOD
PLANS AS002 TO AS005 TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO
ESSERE VISIONATE IN COMBINAZIONE CON LE PIANTE DI QUARTIERE DA AS002 A
AS005 PER IDENTIFICARE LE POSIZIONI ESATTE.
5. (*) WHERE TILES ARE EXPOSED TO EXTERIOR WEATHER CONDITIONS AT
ENTRANCES AND BALCONIES, THEY ARE TO BE WATER RESISTANT AND SLIP
RESISTANT / LE PIASTRELLE ESTERNE DEGLI INGRESSI E DEI BALCONI ESPOSTE
ALLE CONDIZIONI METEOROLOGICHE DEVONO ESSERE TRATTATE CON PRODOTTI
IMPERMEABILIZZANTI E ANTISCIVOLO
6. THE STAIR FLOOR IS FLT-03 AND THE SIZE OF THE PIECES MUST MATCH THE STEPS.
/ IL PAVIMENTO DELLE SCALE È FLT-03 E LA DIMENSIONE DEI PEZZI DEVE
CORRISPONDERE AI GRADINI.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:4 :3
AF ACGMCG
3B R
C O
R N
E R
T H
G R
O U
N D
, F
IR
S T
A N
D S
E C
O N
D F
LR
F
IN
IS
H P
LA
N
3B R
C O
R N
E R
T H
P
IA
N
TA
F
IN
IT
U
R E
P
IA
N O
T E
R R
A , P
R
IM
O E
IN115
14092502
M C G
V ic e n z a
A F H p h a s e
P
TH
A e n ve lo p e .r vt
SCALE 1 : 50
C1
3BR CORNER TH GROUND FLOOR FINISH PLAN /
CORNER TOWNHOUSE 3BR PIANTA FINITURE PIANO TERRA
SCALE 1 : 50
C3
3BR CORNER TH FIRST FLOOR FINISH PLAN /
CORNER TOWNHOUSE 3BR PIANTA FINITURE PRIMO PIANO
SCALE 1 : 50
A1
3BR CORNER TH SECOND FLOOR FINISH PLAN /
CORNER TOWNHOUSE 3BR PIANTA FINITURE SECONDO PIANO
GARAGE
ELECTRICAL ROOM
COMMUNICATION ROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLF-01
FLF-03
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :4
AF ACGMCG
A P
B U
IL
D
IN
G
G
A R
A G
E F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
G A
R A
G E
IN116
14092503
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A A .r vt
SCALE 1 : 50
A1
AP BUILDING 23400 GARAGE FINISH PLAN 1 /
APPARTAMENTO 23400 PIANTA FINITURE GARAGE 1
PLAN
NORTH
NORTH
NORD
F G H I
1 2 3 4 5 6 7 8
GARAGE
MECHANICAL ROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLF-01
FLF-03
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :4
AF ACGMCG
A P
B U
IL
D
IN
G
G
A R
A G
E F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
G A
R A
G E
IN117
14092504
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A A .r vt
SCALE 1 : 50
A1
AP BUILDING 23400 GARAGE FINISH PLAN 2 /
APPARTAMENTO 23400 PIANTA FINITURE GARAGE 2
PLAN
NORTH
H
J
K
3 144
GARAGE
ELECTRICAL ROOM
COMMUNICATION ROOM
MECHANICAL ROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLF-01
FLF-03
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:3 :0
AF ACGMCG
A P
B U
IL
D
IN
G
G
A R
A G
E F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
G A
R A
G E
IN118
14092505
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 23500 GARAGE FINISH PLAN /
AP EDIFICIO 23500 PIANTA FINITURE GARAGE
PLAN
NORTH
DCBA
GARAGE
ELECTRICAL ROOM
COMMUNICATION ROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLF-01
FLF-03
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH INDIVIDUAL APARTMENT
BUILDING PLANS TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO ESSERE
LETTE INSIEME ALLE PIANTE DEI SINGOLI APPARTAMENTI PER INDIVIDUARE LE
POSIZIONI ESATTE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
PLAN
NORTH
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:5 :3
AF ACGMCG
A P
B U
IL
D
IN
G
G
A R
A G
E F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
G A
R A
G E
IN119
14092506
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 23200 GARAGE FINISH PLAN /
APPARTAMENTO 23200 PIANTA FINITURE GARAGE
1 16
D
C
B
A
GARAGE
ELECTRICAL ROOM
COMMUNICATION ROOM
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLF-01
FLF-03
1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE
RIFERIMENTO AL FOGLIO I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI.
2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL
BUILDINGS IN PHASE 2. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION
OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / I PIANI DELLE UNITÀ SONO
RAPPRESENTATIVI DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 2. FARE
RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA
RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ.
3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601
AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA
DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE
TABELLE DELLE FINITURE.
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
0 421 3 5
SCALE: 1:50
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N33191-15-D-0811
CCA/MPO
DER
R. STEPHENS, PE
DPS
AS NOTED
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
2 JUNE 2021
F
IL
E
P A
TH
A U
TH
O R
:1 :2
AF ACGMCG
A P
B U
IL
D
IN
G
G
A R
A G
E F
IN
IS
H P
LA
N
A P
E D
IF
IC
IO
P
IA
N
TA
F
IN
IT
U
R E
G A
R A
G E
IN120
14092507
M C G
V ic e n z a
A F H p h a s e
P A P A e n ve lo p e A .r vt
SCALE 1 : 50
A1
AP BUILDING 26200 GARAGE FINISH PLAN /
AP EDIFICIO 26200 PIANTA FINITURE GARAGE
PLAN
NORTH
IN121
9.26
B4
B2
B1B3
EQ
EQ
EQ
EQ
9.33 10.06 5.33
8.30 8.30
5.09
5.099.33
5.102
5.09 5.079.33
5.102
8.78 5.09
9.33
5.102
EQ
EQ
EQ
26.10
8.30
755.102
FLOOR FINISH LEGEND / LEGENDA
DELLE FINITURE DEL PAVIMENTO:
FLT-11
1. REFER TO SHEET A-001 AND I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. /
RIFERISI ALLA TAVOLA A-001 E I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI
2. THIS DRAWING APPLIES TO ALL APARTMENTS ELEVATOR FINISHES. / QUESTA
TAVOLA SI APPLICA A TUTTE LE FINITURE DEGLI ASCENSORI DEGLI APARTMENTS
GENERAL NOTES THIS SHEET / NOTE
GENERALI SU QUESTA TAVOLA
SCALE:
0.40 1.20.8 1.6
1:20
20.2
M A
R K
D A
TE
D
ES
C R
IP
TI
O N
GRAPHIC SCALE
SCALA GRAFICA
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
T
IO
N
S Y M
P L O
TT
E D
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
P-
0 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
1632846
N3…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .