Attachment I - 1632846dwg23of24.pdf

PDF 22 MB Posted

Attached to
P-91330, Phase 2 Family Housing Villaggio at Vicenza, Italy
Solicitation number
N62470-21-R-0015
Issued by

About this file

This document provides details on a federal solicitation for construction services. The solicitation number is N62470-21-R-0015 and seeks proposals for Phase 2 of the Family Housing Villaggio project at Vicenza, Italy. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Proposals are due on the date specified in the attached solicitation document. The solicitation seeks construction services to complete the second phase of building a family housing village in Vicenza, Italy. Details on the scope of work, specifications, response requirements and other contractual terms are included in the attached solicitation file.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_21JUN2022.pdf PDF
N6247021R0015 Amend 0015.pdf PDF
N6247021R0015 Amend 0014.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247021R0015 Amend 0013.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_10JUN2022.pdf PDF
N6247021R0015 Amend 0012.pdf PDF
Attachment W - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment X - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247021R0015 Amend 0011.pdf PDF
Attachment V - Revised 1632468 Drawings Amendment 0010.pdf PDF
Attachment U - Revised 1632468 Specification Amendment 0010.pdf PDF
N6247021R0015 Amend 0010.pdf PDF
Attachment T - 1632846 Foundation and Misc Revisions Drawings 02of 02.pdf PDF
Attachment R - 1632846 Foundation and Misc Revisions Specifications.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247021R0015 Amend 0009.pdf PDF
Attachment J - PSC Italian Revised March 24 2022.pdf PDF
Attachment S - 1632846 Foundation and Misc Revisions Drawings 01 of 02.pdf PDF
N6247021R0015 Amend 0008.pdf PDF
N6247021R0015 Amend 0007.pdf PDF
Attachment Q Revised 1632468 Drawings Amendment 0006.pdf PDF
N6247021R0015 Amend 0006.pdf PDF
Attachment P Revised 1632468 Specification Amendment 0006.pdf PDF
N6247021R0015 Amend 0005.pdf PDF
Attachment M Pre-proposal Conference Attendee Log.pdf PDF
Attachment N Revised 1632846 Specifications.pdf PDF
Attachment O Revised 1632846 Drawings.pdf PDF
N6247021R0015 Amend 0004.pdf PDF
N6247021R0015 Amend 0003.pdf PDF
N6247021R0015 Amend 0002.pdf PDF
N6247021R0015 Amend 0001.pdf PDF
Attachment I - 1632846dwg20of24.pdf PDF
Attachment I - 1632846dwg09of24.pdf PDF
Attachment I - 1632846dwg04of24.pdf PDF
Attachment I - 1632846dwg10of24.pdf PDF
Attachment I - 1632846dwg14of24.pdf PDF
Attachment I - 1632846dwg11of24.pdf PDF
Attachment I - 1632846dwg08of24.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment I - 1632846dwg24of24.pdf PDF
Attachment I - 1632846dwg13of24.pdf PDF
Attachment H - Specifications.pdf PDF
Attachment I - 1632846dwg02of24.pdf PDF
Attachment I - 1632846dwg03of24.pdf PDF
Attachment I - 1632846dwg18of24.pdf PDF
Attachment I - 1632846dwg12of24.pdf PDF
Attachment L - DWG Index.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
N6247021R0015.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

TOW

17700

E

K

K

K

K

K

K

K

K

K

STAIR

STAIR

STAIR

STAIR

STAIR

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

K

K

K

K

K

K

KK

K

K

K

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :4

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

L

IG

H

TI

N

G S

E C

TI

O

N S

A P

P A

R

TA

M E

N

TO

E D

IF

IC

IO

S E

ZI

O

N I I

LL

U

M

IN

A

ZI

O N

E

EL301

14092900

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A A .r vt

SCALE 1 : 50 (EL101)

A1

STAIRCASE LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI SCALA

SCALE 1 : 50 (EL101)

A3

ELEVATOR SHAFT LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI ELEVATORE VANO DI CORSA

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED EXCEPT IN GARAGES IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA AD ECCEZIONE DEI GARAGE IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

CDE

K

K

K

K

K

K

K

K

K

K K

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

TOW

17700

GE

K

K

K

K

K

K

K

K

K

X

STAIR

STAIR

STAIR

STAIR

STAIR

STAIR

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :2

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

L

IG

H

TI

N

G S

E C

TI

O

N S

A P

P A

R

TA

M E

N

TO

E D

IF

IC

IO

S E

ZI

O

N I I

LL

U

M

IN

A

ZI

O N

E

EL302

14092901

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50 (EL106)

A3

ELEVATOR SHAFT LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI ELEVATORE VANO DI CORSA

SCALE 1 : 50 (EL106)

A1

STAIRCASE LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI SCALA

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

QUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED EXCEPT IN GARAGES IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA AD ECCEZIONE DEI GARAGE IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

TOW

17700

GED F

K

K

K

K

K

K

K

K

K

STAIR

STAIR

STAIR

STAIR

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

K K

K K

K K

K K

K K

K

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :2

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

L

IG

H

TI

N

G S

E C

TI

O

N S

A P

P A

R

TA

M E

N

TO

E D

IF

IC

IO

S E

ZI

O

N I I

LL

U

M

IN

A

ZI

O N

E

EL303

14092902

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50 (EL111)

A1

STAIRCASE LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI SCALA

SCALE 1 : 50 (EL111)

A3

ELEVATOR SHAFT LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI ELEVATORE VANO DI CORSA

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED EXCEPT IN GARAGES IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA AD ECCEZIONE DEI GARAGE IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

TOW

17700

GED F

K

K

K

K

K

K

K

K

K

STAIR

STAIR

STAIR

STAIR

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

K

K K

K K

K K

K K

K K

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :4

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

L

IG

H

TI

N

G S

E C

TI

O

N S

A P

P A

R

TA

M E

N

TO

E D

IF

IC

IO

S E

ZI

O

N I I

LL

U

M

IN

A

ZI

O N

E

EL304

14092903

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50 (EL116)

A1

STAIRCASE LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI SCALA

SCALE 1 : 50 (EL116)

A3

ELEVATOR SHAFT LIGHTING SECTION /

SEZIONE ILLUMINAZIONE DI ELEVATORE VANO DI CORSA

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED EXCEPT IN GARAGES IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA AD ECCEZIONE DEI GARAGE IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

FCU-1 FCU-1

FCU-1 FCU-1

FCU-1 FCU-1

2P 40A

FPM 2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

HP-11

EP-9 EP-9

EP-9 EP-9

EP-9 EP-9

CORRIDOR

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

DSS-2

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

2P 40A

FPM

2P 40A

FPM

FCU-1 FCU-1

FCU-1 FCU-1

2P 40A

FPM

2P 40A

FPM

FCU-1 FCU-1

2P 40A

FPM

2P 40A

FPM

EP-9 EP-9

EP-9 EP-9

EP-9 EP-9

CORRIDOR

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :1

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

E

LE

C

TR

IC

A L

S E

C

TI

O N

S A

P P

A R

TA

M

E N

TO

E

D

IF

IC

IO

S

E

ZI

O N

I I M

P

IA

N

TO

E

LE

TT

R

IC

O

EP301

14092904

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A A .r vt

SCALE 1 : 50 (EP102)

A1

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

SCALE 1 : 50 (EP102)

A3

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. SEE MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

AND ELECTRICAL LOADS OF MECHANICAL AND PLUMBING EQUIPMENT. /

VEDERE LE TAVOLE DEGLI IMPIANTI MECCANICI E IDRAULICI PER ULTERIORI

INFORMAZIONI E PER VERIFICARE I CARICHI ELETTRICI DI APPARECCHIATURE

MECCANICHE E IDRAULICHE.

4. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

5. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN

GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE CONFIGURAZIONI DEI

CIRCUITI ELETTRICI SONO SCHEMATICHE E LE CONNESSIONI INDICATE

RAPPRESENTANO LA STRATEGIA DI CONTROLLO. FORNIRE CIRCUITI NON A

VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ ALLE NORME CEI.

6. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

7. REFER TO PENTHOUSE PLAN FOR UNITS CONNECTION TO HEAT PUMP. / FARE

RIFERIMENTO ALLA PIANTA DELL'ATTICO PER VEDERE LE UNITA' CONNESSE

ALLE POMPE DI CALORE.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. ALL THE DISCONNECT SWITCH MUST BE A MINIMUM PROTECTION IP55. /

TUTTI GLI INTERRUTTORI SEZIONATORI DEVONO AVERE UNA PROTEZIONE

MINIMA IP55.

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

EP-9

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

FCU-1 FCU-1

FCU-1 FCU-1

FCU-1FCU-1

EP-9

EP-9 EP-9

EP-9 EP-9

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

2P 40A

FPM

MEP_GROUND FFL

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

CDE

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

EP-9

FCU-1

FCU-1

FCU-1

FCU-1

EP-9

EP-9

EP-9

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :5

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

E

LE

C

TR

IC

A L

S E

C

TI

O N

S A

P P

A R

TA

M

E N

TO

E

D

IF

IC

IO

S

E

ZI

O N

I I M

P

IA

N

TO

E

LE

TT

R

IC

O

EP302

14092905

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50 (EP107)

A1

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

SCALE 1 : 50 (EP106)

A3

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. SEE MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

AND ELECTRICAL LOADS OF MECHANICAL AND PLUMBING EQUIPMENT. /

VEDERE LE TAVOLE DEGLI IMPIANTI MECCANICI E IDRAULICI PER ULTERIORI

INFORMAZIONI E PER VERIFICARE I CARICHI ELETTRICI DI APPARECCHIATURE

MECCANICHE E IDRAULICHE.

4. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

5. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED EXCEPT IN

GARAGES IN ACCORDANCE WITH CEI NORMS. / LE CONFIGURAZIONI DEI

CIRCUITI ELETTRICI SONO SCHEMATICHE E LE CONNESSIONI INDICATE

RAPPRESENTANO LA STRATEGIA DI CONTROLLO. FORNIRE CIRCUITI NON A

VISTA AD ECCEZIONE DEI GARAGE IN CONFORMITÀ ALLE NORME CEI.

6. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

7. REFER TO PENTHOUSE PLAN FOR UNITS CONNECTION TO HEAT PUMP. / FARE

RIFERIMENTO ALLA PIANTA DELL'ATTICO PER VEDERE LE UNITA' CONNESSE

ALLE POMPE DI CALORE.

8. ALL CONDUIT RIGID OR FLEXIBLE SHALL MUST (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. ALL THE DISCONNECT SWITCH MUST BE A MINIMUM PROTECTION IP55. /

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

GF

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

EP-10

FCU-1

FCU-2

FCU-2

FCU-2

EP-10

EP-10

EP-10

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

987 10

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

EP-9

FCU-1 FCU-1

FCU-1FCU-1

FCU-1 FCU-1

EP-9

EP-9 EP-9

EP-9 EP-9

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :1

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

E

LE

C

TR

IC

A L

S E

C

TI

O N

S A

P P

A R

TA

M

E N

TO

E

D

IF

IC

IO

S

E

ZI

O N

I I M

P

IA

N

TO

E

LE

TT

R

IC

O

EP303

14092906

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50 (EP111)

A1

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

SCALE 1 : 50 (EP112)

A3

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. SEE MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

AND ELECTRICAL LOADS OF MECHANICAL AND PLUMBING EQUIPMENT. /

VEDERE LE TAVOLE DEGLI IMPIANTI MECCANICI E IDRAULICI PER ULTERIORI

INFORMAZIONI E PER VERIFICARE I CARICHI ELETTRICI DI APPARECCHIATURE

MECCANICHE E IDRAULICHE.

4. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

5. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN

GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE CONFIGURAZIONI DEI

CIRCUITI ELETTRICI SONO SCHEMATICHE E LE CONNESSIONI INDICATE

RAPPRESENTANO LA STRATEGIA DI CONTROLLO. FORNIRE CIRCUITI NON A

VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ ALLE NORME CEI.

6. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

7. REFER TO PENTHOUSE PLAN FOR UNITS CONNECTION TO HEAT PUMP. / FARE

RIFERIMENTO ALLA PIANTA DELL'ATTICO PER VEDERE LE UNITA' CONNESSE

ALLE POMPE DI CALORE.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. ALL THE DISCONNECT SWITCH MUST BE A MINIMUM PROTECTION IP55. /

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

GF

FCU-2

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

2P 40A

FPM

EP-10

EP-10

EP-10

EP-10

FCU-1

FCU-2

FCU-2

HC-3

HC-3

HC-3

HC-1

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MEP_SECOND FFL

MEP_FIRST FFL

MEP_THIRD FFL

10200

MEP_PENTHOUSE FFL

13600

987 10

2P 40A

FPM

2P 40A

FPM

FCU-1 FCU-1

2P 40A

FPM

2P 40A

FPM

FCU-1FCU-1

2P 40A

FPM

2P 40A

FPM

FCU-1FCU-1

EP-9EP-9

EP-9 EP-9

EP-9EP-9

HC-2 HC-2

HC-2 HC-2

HC-2 HC-2

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

KEYPLAN / PIANO STRATEGICO

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :1

JSG JMMMVA

A P

A R

TM

E

N T

B U

IL

D

IN

G

E

LE

C

TR

IC

A L

S E

C

TI

O N

S A

P P

A R

TA

M

E N

TO

E

D

IF

IC

IO

S

E

ZI

O N

I I M

P

IA

N

TO

E

LE

TT

R

IC

O

EP304

14092907

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50 (EP116)

A1

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

SCALE 1 : 50 (EP117)

A3

MECHANICAL ROOM ELECTRICAL SECTIONS /

SEZIONI IMPIANTO ELETTRICO DI SALA MACCHINE

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. SEE MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

AND ELECTRICAL LOADS OF MECHANICAL AND PLUMBING EQUIPMENT. /

VEDERE LE TAVOLE DEGLI IMPIANTI MECCANICI E IDRAULICI PER ULTERIORI

INFORMAZIONI E PER VERIFICARE I CARICHI ELETTRICI DI APPARECCHIATURE

MECCANICHE E IDRAULICHE.

4. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

5. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC. UNLESS

OTHERWISE NOTED, PROVIDE CIRCUITRY ROUTING CONCEALED, EXCEPT IN

GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE CONFIGURAZIONI DEI

CIRCUITI ELETTRICI SONO SCHEMATICHE E LE CONNESSIONI INDICATE

RAPPRESENTANO LA STRATEGIA DI CONTROLLO. FORNIRE CIRCUITI NON A

VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ ALLE NORME CEI.

6. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

7. REFER TO PENTHOUSE PLAN FOR UNITS CONNECTION TO HEAT PUMP. / FARE

RIFERIMENTO ALLA PIANTA DELL'ATTICO PER VEDERE LE UNITA' CONNESSE

ALLE POMPE DI CALORE.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. ALL THE DISCONNECT SWITCH MUST BE A MINIMUM PROTECTION IP55. /

CAP

PANEL SP

LC 27.083

26.010

26.006

EF-2

2P, 32A

TRANSFORMER ENCLOSURE /

INVOLUCRO DEL

TRASFORMATORE

TRANSFORMER MEDIUM

VOLTAGE TERMINAL /

TERMINALE MEDIA TENSIONE

DEL TRASFORMATORE

MEDIUM VOLTAGE WIRE /

CAVO A MEDIA TENSIONE

MEDIUM VOLTAGE WIRE / CAVO

A MEDIA TENSIONE

SUBSTATION FLOOR /

PAVIMENTO SOTTOSTAZIONE

TRENCH /

TRINCEA

KEYPLAN

0 421 3 5

SCALE: 1:50

M A

R K

D A T E

D E

S C

R

IP

T

IO

N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

G

IO

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

T L A

N T

IC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

T

IO

N

S Y M

P L O T T E D

H

AM

P

TO

N

B

LV

D

VI

C E N Z A, IT

AL

Y

P -9

A R

M Y

F A

M

IL

Y H

O U

S

IN

G P

R O

JE

C

T

AECOM

10 S. Jefferson Street, Suite 1600

Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

2 JUNE 2021

:5 :2

P M

RHS RCCKRT

S U

B S

T A

T

IO

N B

U

IL

D

IN

G E

L E

C T

R

IC

A L S

E C

T

IO

N S

P

IA

N T

E S

O T

T O

S T

A Z

IO

N

E S

E Z

IO

N

I

IM

P

IA

N T

O E

L E

T T

R

IC

O

EP311

14092908 1313 1407

SCALE: 1 : 50 (EP122)

C1

ELECTRICAL SUBSTATION SECTION VIEW

EAST / SOTTOSTAZIONE ELETTRICA VISTA IN

SEZIONE EST

GENERAL NOTES THIS SHEET:/

NOTE GENERALI DI QUESTO FOGLIO:

A. SEE ARCHITECTURAL, ELECTRICAL SITE AND CIVIL PLANS FOR

LOCATIONS AND NAMES OF BUILDINGS.

26.006 RESPECTIVE SUBSTATION LOW VOLTAGE ELECTRICAL SITE PANEL SP. SEE

SHEET ES645./ QUADRO DI DISTRIBUZIONE BASSA TENSIONE SP. VEDERE

LE TAVOLE DALLA ES645.

26.010 UPS FOR MVS, 9 KVA WITH 8 EACH 16/2P CIRCUIT BREAKERS FOR COMM

CABINET AND MVS CIRCUIT BREAKER. SEE UPS PANEL SCHEDULE. SEE

SPECIFICATIONS. / UPS PER MVS 9KVA. CON 8 INTERRUTTORI CIASCUNO

16A/2F PER AMADIETTO COMUNICAZIONI E INTERRUTTORE CIRCUITO MVS.

VEDERE TABELLA QUADRO UPS. VEDERE SPECIFICHE.

27.083 PROVIDE TELECOMMUNICATIONS CABINET. SEE DETAIL A1/TS502. /

FORNIRE ARMADIO TELECOMUNICAZIONI. VEDI DETTAGLIO A1/TS502

SHEET KEYNOTES: / NOTE CHIAVE

DI QUESTO FOGLIO

SCALE: 1 : 50 (EP122)

A1

TRANSFORMER MEDIUM VOLTAGE

CONNECTION / CONNESSIONE A MEDIA

TENSIONE DEL TRASFORMATORE

A1

E

F

F

C

A1 G3

A1

G3

A1

A

A

AAA

B2

A

B1B1B1B2

A A

A1

D

D

A

EM

EM

F

F F

F

F

J

B2

2 5 9 12 14

I

G

H

J

43 8 156 7 10 11 13

A008

MASTER BEDROOM

A009

MASTER CLOSET

A010

MASTER BATHROOM

A011

BATHROOM 2

A014

CIRCULATION

A007

BEDROOM 3

A006

BEDROOM 2

A005

LIVING ROOM

A015

BALCONY

A004

KITCHEN

A003

DINING

A002

FAMILY

A001

FOYER

A013

STORAGE

A012

LAUNDRY

26.203

26.202

26.205

26.204 26.219

26.209

26.208

26.207

26.206

26.211

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :5

JSG JMMMVA

3B R

A P

A R

TM

E

N T

G R

O U

N D

F

LO

O R

L

IG

H

TI

N G

P

LA

N P

IA

N

TA

IL

LU

M

IN

A

ZI

O

N E

B

R A

P P

A R

TA

M

E N

TO

P

IA

N

O T

E R

R A

EL401

14092909

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50

A1

3BR APARTMENT GROUND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR APPARTAMENTO PIANO TERRA

(EL111)

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED, EXCEPT IN GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. INTERIOR LIGHTING IS FED FROM: EP-11 (AP AND TH 3BR, TH-4BR), EP-12 (AP

4BR). OUTDOOR LIGHTING IS FED FROM: EP-16 (AP 3BR), EP-17 (AP 4BR AND TH).

/ L'ILLUMINAZIONE INTERNA È ALIMENTATA DAI QUADRI LETTRICI: EP-11 (AP E

TH 3BR, TH-4BR), EP-12 (AP 4BR). L'ILLUMINAZIONE ESTERNA È ALIMENTATA DAI

QUADRI ELETTRICI: EP-16 (AP 3BR), EP-17 (AP 4BR E TH).

10. FOR SITE LIGHTING LOCATION ON BUILDINGS FAÇADE (POWERED FROM

THIS BUILDING), PLEASE REFER TO SITE PLANS ES111 TO ES117 AND ES130. /

PER LA POSIZIONE DELL'ILLUMINAZIONE DEL CANTIERE SULLA FACCIATA DEGLI

EDIFICI (ALIMENTATO DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLE TAVOLE

DEL CANTIERE DA ES111 A ES117 E ES130.

SHEET KEYNOTES /

NOTE CHIAVE DELLA TAVOLA:

26.202 LIGHTING FIXTURE A. SEE SHEET C1/EL501. / CORPO ILLUMINANTE A.

VEDERE TAVOLA C1/EL501.

26.203 LIGHTING FIXTURE A1. SEE SHEET C2/EL501. / CORPO ILLUMINANTE A1.

VEDERE TAVOLA C2/EL501.

26.204 LIGHTING FIXTURE B1. SEE SHEET C3/EL501. / CORPO ILLUMINANTE B1.

VEDERE TAVOLA C3/EL501.

26.205 LIGHTING FIXTURE B2. SEE SHEET C4/EL501. / CORPO ILLUMINANTE B2.

VEDERE TAVOLA C4/EL501.

26.206 LIGHTING FIXTURE C. SEE SHEET A1/EL501. / CORPO ILLUMINANTE C.

VEDERE TAVOLA A1/EL501.

26.207 LIGHTING FIXTURE D. SEE SHEET A2/EL501. / CORPO ILLUMINANTE D.

VEDERE TAVOLA A2/EL501.

26.208 LIGHTING FIXTURE E. SEE SHEET A3/EL501. / CORPO ILLUMINANTE E.

VEDERE TAVOLA A3/EL501.

26.209 LIGHTING FIXTURE EM. SEE SHEET A4/EL501. / CORPO ILLUMINANTE EM.

VEDERE TAVOLA A4/EL501.

26.211 LIGHTING FIXTURE F. SEE SHEET C2/EL502. / CORPO ILLUMINANTE F.

VEDERE TAVOLA C2/EL502.

26.219 LIGHTING FIXTURE G3. SEE SHEET B3/EL503. / CORPO ILLUMINANTE G3.

VEDERE TAVOLA B3/EL503.

C

D

D

E F

A

A1

A

A A

A

B1

A

B2

A1

A1A1

A1

A

A

A

B2

B1B1

F

EM

EM

G3

A

G3

B2 J

C

D

D

E F

A

A1

A

A A

A

B1

A

B2

A1

A1A1

A1

A

A

A

B2

B1B1

F

EM

EM

G3

A

G3

B2 J

DCBA

E207

MASTER BEDROOM

E206

BEDROOM 2

E205

BEDROOM 3

E204

LIVING ROOM

E215

BALCONY

E203

KITCHEN

E202

DINING

E214

CIRCULATION

E201

FOYER

E213

STORAGEE212

FAMILY

E211

LAUNDRY

E210

BATHROOM 2

E209

MASTER BATHROOM

E208

MASTER CLOSET

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :5

JSG JMMMVA

3B R

A P

A R

TM

E

N T

TY

P

IC

A

L

FL

O O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

A P

P A

R

TA

M E

N

TO

P

IA

N O

T

IP

IC

O

EL402

14092910

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50

A1

3BR APARTMENT TYPICAL FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR APPARTAMENTO PIANO TIPICO

(EL103)

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED, EXCEPT IN GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. INTERIOR LIGHTING IS FED FROM: EP-11 (AP AND TH 3BR, TH-4BR), EP-12 (AP

4BR). OUTDOOR LIGHTING IS FED FROM: EP-16 (AP 3BR), EP-17 (AP 4BR AND TH).

/ L'ILLUMINAZIONE INTERNA È ALIMENTATA DAI QUADRI LETTRICI: EP-11 (AP E

TH 3BR, TH-4BR), EP-12 (AP 4BR). L'ILLUMINAZIONE ESTERNA È ALIMENTATA DAI

QUADRI ELETTRICI: EP-16 (AP 3BR), EP-17 (AP 4BR E TH).

10. FOR SITE LIGHTING LOCATION ON BUILDINGS FAÇADE (POWERED FROM

THIS BUILDING), PLEASE REFER TO SITE PLANS ES111 TO ES117 AND ES130. /

PER LA POSIZIONE DELL'ILLUMINAZIONE DEL CANTIERE SULLA FACCIATA DEGLI

EDIFICI (ALIMENTATO DA QUESTO EDIFICIO), FARE RIFERIMENTO ALLE TAVOLE

DEL CANTIERE DA ES111 A ES117 E ES130.

A

B2

B1 B1

A

A

B1

A1 A1

G1 A A1

C

A1

E

D D

A

A

A A

EM

EM

G3

A

B2

B2

F F

F

F

F

F

F

J

2 5 9 12 14

I

G

H

J

43 8 156 7 10 11 13

A008

MASTER BEDROOM

A014

CIRCULATION

A006

BEDROOM 2

A005

LIVING ROOM

A003

DINING

A004

KITCHEN

A015

BALCONY

A002

FAMILY

A001

FOYER

A013

STORAGE

A012

LAUNDRY

A011

BATHROOM 2

A010

MASTER BATHROOM

A007

BEDROOM 3

A009

MASTER CLOSET

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :5

JSG JMMMVA

3B R

A P

A R

TM

E

N T

A B

A G

R O

U N

D F

LO

O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

A P

P A

R

TA

M E

N

TO

A B

A P

IA

N

O T

E R

R A

EL403

14092911

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50

A1

3BR APARTMENT ABA GROUND FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR APPARTAMENTO ABA PIANO TERRA

(EL116)

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED, EXCEPT IN GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. INTERIOR LIGHTING IS FED FROM: EP-11 (AP AND TH 3BR, TH-4BR), EP-12 (AP

4BR). OUTDOOR LIGHTING IS FED FROM: EP-16 (AP 3BR), EP-17 (AP 4BR AND TH).

/ L'ILLUMINAZIONE INTERNA È ALIMENTATA DAI QUADRI LETTRICI: EP-11 (AP E

TH 3BR, TH-4BR), EP-12 (AP 4BR). L'ILLUMINAZIONE ESTERNA È ALIMENTATA DAI

QUADRI ELETTRICI: EP-16 (AP 3BR), EP-17 (AP 4BR E TH).

10. FOR SITE LIGHTING LOCATION ON BUILDINGS FAÇADE (POWERED FROM

THIS BUILDING), PLEASE REFER TO SITE PLANS ES111 TO ES117 AND ES130. /

PER LA POSIZIONE DELL'ILLUMINAZIONE DEL CANTIERE SULLA FACCIATA DEGLI

E

F

C

A

A

A1

B1

A

A

A1

A1

A1 A1

AAA

A

A

D

D

A

EM

EM

G3

A

B2 B2 G3

F

B1 B1

B2 J

DC

BA

C107

MASTER BEDROOM

C108

MASTER CLOSET

C114

CIRCULATION

C109

MASTER BATHROOM

C110

BATHROOM 2 C111

LAUNDRY

C112

FAMILY

C113

STORAGE

C101

FOYER

C102

DINING

C103

KITCHEN

C104

LIVING ROOM

C115

BALCONY

C105

BEDROOM 3

C106

BEDROOM 2

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:3 :4

JSG JMMMVA

3B R

A P

A R

TM

E

N T

A B

A F

LO

O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

A P

P A

R

TA

M E

N

TO

A B

A P

IA

N

O

EL404

14092912

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A A .r vt

SCALE 1 : 50

A1

3BR APARTMENT ABA FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 3BR APPARTAMENTO ABA PIANO

(EL102)

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED, EXCEPT IN GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. INTERIOR LIGHTING IS FED FROM: EP-11 (AP AND TH 3BR, TH-4BR), EP-12 (AP

4BR). OUTDOOR LIGHTING IS FED FROM: EP-16 (AP 3BR), EP-17 (AP 4BR AND TH).

/ L'ILLUMINAZIONE INTERNA È ALIMENTATA DAI QUADRI LETTRICI: EP-11 (AP E

TH 3BR, TH-4BR), EP-12 (AP 4BR). L'ILLUMINAZIONE ESTERNA È ALIMENTATA DAI

QUADRI ELETTRICI: EP-16 (AP 3BR), EP-17 (AP 4BR E TH).

10. FOR SITE LIGHTING LOCATION ON BUILDINGS FAÇADE (POWERED FROM

THIS BUILDING), PLEASE REFER TO SITE PLANS ES111 TO ES117 AND ES130. /

PER LA POSIZIONE DELL'ILLUMINAZIONE DEL CANTIERE SULLA FACCIATA DEGLI

E

C

DDD

F

F

A

A

A1

A1

B2

B1

A1

A

A

A B2

B1B1

A1

A

A A

A

A

EM

EM

F

G3

G3

EM

FFF

B2

F F

F

J

2 5 9 12 14

I

G

E

H

J

43 8 156 7 10 11 13

F

G208

MASTER BEDROOM

G209

MASTER CLOSET

G215

CIRCULATION

G211

BEDROOM 4

G212

BATHROOM 2

G213

LAUNDRY

G214

STORAGE

G201

FOYER

G202

FAMILY

G203

LIVING ROOM

G205

DINING

G204

KITCHEN

G216

BALCONY

G207

BEDROOM 2

G206

BEDROOM 3

G210

MASTER BATHROOM

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :4

JSG JMMMVA

4B R

A P

A R

TM

E

N T

TY

P

IC

A

L

FL

O O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

A P

P A

R

TA

M E

N

TO

P

IA

N O

T

IP

IC

O

EL405

14092913

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50

A1

4BR APARTMENT TYPICAL FLOOR LIGHTING PLAN /

PIANTA ILLUMINAZIONE 4BR APPARTAMENTO PIANO TIPICO

(EL106)

GENERAL SHEET NOTES/

NOTE GENERALI DI QUESTO FOGLIO:

1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /

VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E

ABBREVIAZIONI.

2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER

LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E

CIVILI.

3. COORDINATE FINAL FIXTURE LOCATIONS WITH INSTALLED MECHANICAL

EQUIPMENT. / COORDINARE LE POSIZIONI FINALI DELLE ATTREZZATURE CON

L'ATTREZZATURA MECCANICA INSTALLATA.

4. SEE INTERIOR LIGHTING FIXTURE SCHEDULE SHEET EL601, AND INTERIOR

LIGHTING FIXTURE DETAILS SHEETS EL501 AND EL502 FOR

SPECIFICATION/REQUIREMENTS OF FIXTURES. / VEDERE LE TAVOLE ABACO

CORPI ILLUMINANTI INTERNI EL601, E TAVOLE DETTAGLI CORPI ILLUMINANTI

INTERNI EL501 E EL502 PER LE SPECIFICHE/REQUISITI DEI CORPI ILLUMINANTI.

5. SEE PANELBOARD SCHEDULES SHEETS EP620 TO EP631 FOR CIRCUIT

DESIGNATIONS. / VEDERE LE TAVOLE ABACO QUADRO ELETTRICO DA EP620 A

EP631 PER IL CIRCUITO DI RIFERIMENTO.

6. ELECTRICAL WIRING CIRCUIT LAYOUTS ARE SCHEMATIC AND CONNECTIONS

SHOWN REPRESENT THE CONTROL STRATEGY. PROVIDE CIRCUITRY ROUTING

CONCEALED, EXCEPT IN GARAGES, IN ACCORDANCE WITH CEI NORMS. / LE

CONFIGURAZIONI DEI CIRCUITI ELETTRICI SONO SCHEMATICI E LE

CONNESSIONI INDICATE RAPPRESENTANO LA STRATEGIA DI CONTROLLO.

FORNIRE CIRCUITI NON A VISTA, AD ECCEZIONE DEI GARAGE, IN CONFORMITÀ

ALLE NORME CEI.

7. UNLESS OTHERWISE INDICATED, ROUTE CIRCUITRY CONCEALED IN

RESIDENTIAL UNITS, CORE/STAIR AREAS OF APARTMENTS, AND FINISHED

AREAS. / SALVO DIVERSAMENTE INDICATO, CABLAGGI NON A VISTA NELLE

UNITA 'RESIDENZIALI, VANI CENTRALI / SCALE DEGLI APPARTAMENTI E NELE

ZONE CON FINITURE SUPERFICIALI.

8. ALL CONDUIT RIGID OR FLEXIBLE MUST BE (1) ∅ 25MM MINIMUM. / TUTTI I

CONDOTTI RIGIDI O FLESSIBILI DEVONO AVERE (1) ∅ 25 MM MINIMO.

9. INTERIOR LIGHTING IS FED FROM: EP-11 (AP AND TH 3BR, TH-4BR), EP-12 (AP

4BR). OUTDOOR LIGHTING IS FED FROM: EP-16 (AP 3BR), EP-17 (AP 4BR AND TH).

/ L'ILLUMINAZIONE INTERNA È ALIMENTATA DAI QUADRI LETTRICI: EP-11 (AP E

TH 3BR, TH-4BR), EP-12 (AP 4BR). L'ILLUMINAZIONE ESTERNA È ALIMENTATA DAI

QUADRI ELETTRICI: EP-16 (AP 3BR), EP-17 (AP 4BR E TH).

10. FOR SITE LIGHTING LOCATION ON BUILDINGS FAÇADE (POWERED FROM

THIS BUILDING), PLEASE REFER TO SITE PLANS ES111 TO ES117 AND ES130. /

PER LA POSIZIONE DELL'ILLUMINAZIONE DEL CANTIERE SULLA FACCIATA DEGLI

A

E

F

F

F

C

D

D

D

A1

B1 A

A1

A1

A

A

A

B2 B1B1

A1

A

A A

A

A

EM

EMEM

G3

G3

B2

F F B2

F F

F

J

2 5 9 12 14

I

G

E

H

J

43 8 156 7 10 11 13

F

D108

MASTER BEDROOM

D109

MASTER CLOSET

D110

MASTER BATHROOM

D111

BEDROOM 4

D112

BATHROOM 2

D113

LAUNDRY

D101

FOYER

D114

STORAGE

D102

FAMILY

D103

LIVING ROOM

D116

BALCONY

D104

KITCHEN

D105

DINING

D115

CIRCULATION

D107

BEDROOM 2

D106

BEDROOM 3

0 421 3 5

SCALE: 1:50

M

AR

K D A

TE

D

ES

C R

IP

TI

O N

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

P L O

TT

E D

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

P-

0 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

1632846

N33191-15-D-0811

CCA/MPO

DER

R. STEPHENS, PE

DPS

AS NOTED

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

2 JUNE 2021

F

IL

E

P A

TH

A U

TH

O R

:4 :4

JSG JMMMVA

4B R

A P

A R

TM

E

N T

A B

A F

LO

O

R L

IG

H

TI

N

G P

LA

N

P

IA

N

TA

IL

LU

M

IN

A

ZI

O N

E

B R

A P

P A

R

TA

M E

N

TO

A B

A P

IA

N

O

EL406

14092914

M V A

V ic e n z a

A F H p h a s e

P A P M e n ve lo p e A .r vt

SCALE 1 : 50

A1

4BR APARTMENT ABA FLOOR LIGHTING PLAN /

PIAN…

This is the start of the file's text. The full file is on GovTribe.