WI 501 Ref 2.4 Drew Technical Product Sheet MC-PD-46.pdf

PDF 593 KB Posted

Attached to
PSA of USNS MATTEW PERRY (T-AKE 9) and USNS CHARLES DREW (T-AKE 10)
Solicitation number
N40442-10-R-3012
Issued by

About this file

WI 501 Reference

View the file

Other files

File Type Posted
0021_A_CLEAN AND GAS FREE TANKS VOIDS AND COFFERDAMS.doc DOC document
10-R-3012 amendment 5.doc DOC document
SM1000-01_A-REV.pdf PDF
SM1000-02_A-REV.pdf PDF
SM1000-03_A-REV.pdf PDF
350-000-01.pdf PDF
1INFORMATION DATA.doc DOC document
10-R-3012 amendment 4.doc DOC document
SM1000_TP.pdf PDF
0109_A_ Bilge Well Preservation.doc DOC document
0021_A_CLEAN AND GAS FREE TANKS VOIDS AND COFFERDAMS.doc DOC document
0003_NSP_ APPROACH BERTH AND MOORING.doc DOC document
10-R-3012 amendment 3.doc DOC document
WI 560 Calcium Carbonate Dosing System.docx DOCX document
GFM List for WI Index Amend 3.xls XLS spreadsheet
References for WI Index T-AKE 9 PSA Amend 2.xls XLS spreadsheet
0003_NSP_ APPROACH BERTH AND MOORING.doc DOC document
10-R-3012 amendment 2.doc DOC document
0622_A_Second Deck Cargo Hold Modifications.doc DOC document
GFM List for WI Index T-AKe 9 PSA Amend 2.xls XLS spreadsheet
WI 501 Ref 2.5 Drew Removal of Corrosion Products T-AKE.doc DOC document
261-7488730_D 1.DWG DWG drawing
7488748_B.doc DOC document
WI 0561 Senitec OWS Sys Installation.doc DOC document
Ref for WI Index T-AKE 10 PSA Amend 1.xls XLS spreadsheet
0547_A_HP Crossover to EDG Start Air System.doc DOC document
2.7 Attachment 7 Ball Valve Removal Photo.pdf PDF
0617_A_06 Lvl Vent Trunk Door Install.doc DOC document
261-7488730_D 2.DWG DWG drawing
7488951_L.pdf PDF
479-341-7012_--_SRD_Appendix A.DOC DOC document
GFM List for WI Index.xls XLS spreadsheet
8390078 Senitec OWS Installation .pdf PDF
7488736_D Distilled Water Transfer Sys Diagram.pdf PDF
T6435-CM-MMC-010.pdf PDF
261-7488730_D 3.DWG DWG drawing
7488736_D.pdf PDF
529-74 3.DWG DWG drawing
261-8389758 B - Mn Diesel Gen Remote Fuel Isolation Valve Install.pdf PDF
2.2 Attachment 2 471-342-7126_C-SRD_004.dwg DWG drawing
479-341-7012_--_SRD_Appendix D.xls XLS spreadsheet
2.6 Attachment 6 On Line and Recirc Manifold locations photos.pdf PDF
20001700 REV C Transmitter Installation Man.pdf PDF
479-341-7012_--_SRD_Appendix C.DOC DOC document
20002298REV C F-Series Meter Install Manual.pdf PDF
261-7488730_D 5.DWG DWG drawing
529-74 1.PDF PDF
WI 205 FO Meter Replacement.doc DOC document
9197402200E Senitec M1000 Assembling Instructions.pdf PDF
GFM List for WI Index.xls XLS spreadsheet
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

®Registered trademark, TMTrademark, Drew Marine ©2009 Drew Marine • All Rights Reserved • MC-PD-46 (9/09) R8 www.drew-marine.com

All statements, information and data presented herein are believed to be accurate and reliable but are not to be taken as a guarantee, express warranty or implied warranty of merchantability or fitness for a particular purpose, or representation, express or implied, for which seller assumes legal responsibility, and they are offered solely for your consideration, investigation and verification. Statements or suggestions concerning possible use of this product are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patent.

DREW MARINE • One Drew Plaza, Boonton, NJ 07005 USA • Tel: (1-973) 263-7600 • Fax: (1-973) 263-4491

FERROCLEAN® Cleaning Treatment

TECHNICAL PRODUCTS

Description

FERROCLEAN cleaning treatment is a unique, patented, highly effective water-based cleaner containing penetrating, dissolving and dispersing agents. FERROCLEAN clean-ing treatment removes, dissolves and disperses iron oxide deposits from diesel cooling water systems while providing a passivating film to protect the base metal from corrosion.

Iron fouling in cooling water systems can negatively affect the overall operation of the system resulting in reduced operating efficiency, increased maintenance costs and downtime as well as shortened equipment life.

FERROCLEAN cleaning treatment effectively removes iron oxides without subjecting the system metallurgy to the hazards of handling and metal loss associated with using strong acid solutions. FERROCLEAN cleaning treatment also loosens and disperses organic debris trapped in the iron oxide deposits and removes mineral scale in the presence of light oil contamination.

FERROCLEAN cleaning treatment is not recommended for use on galvanized metal.

Continued on page 2

Application and Use

FERROCLEAN cleaning treatment is an effective cleaner for removing oxides, scale and oil without the need for neu-tralization. Using good quality, fresh water, circulate a 10% solution of FERROCLEAN cleaning treatment through the equipment. Depending upon the extent of the fouling, the solution strength, contact time and temperature may be var-ied. Elevated temperatures will improve the cleaning process.

In the event of a heavily fouled cooling water system, more than one cleaning may be required.

After the cleaning process has been completed using FERROCLEAN cleaning treatment, the system should be drained and thoroughly flushed with fresh water. A quality corrosion inhibitor, such as MAXIGARD® diesel engine treatment, LIQUIDEWT™ cooling water treatment, or DEWT® NC diesel engine water treatment should then be immediately used to protect the system.

Features Benefits

Water-based cleaner Non-flammable Easily disperses in water

Penetrates and disperses deposits Decreases maintenance costs Increases equipment life Increases operating efficiency Dissolved deposits do not redeposit, and loosened materials are kept in suspension Effective removal of oxides, scale and oil

Patented formulation Unique product

Safe for use on most metals Safe for use on aluminum, brass, copper, mild steel, and stain-less steel

Leaves passivating film Protects metallurgy from corrosion after cleaning Prevents flash rusting

No objectionable odor Pleasant to work with and no lingering odor

Contains emulsifiers and dispersing agents Can be used where there is light oil contamination without precleaning

Contains antifoam Reduces foam

MC-PD-46 (9/09) R8

For a pre-commissioning cleaning, circulate a solution of 2% FERROCLEAN cleaning treatment through the equip-ment. If cleaning is to be performed without heat, circulate for several days, depending on the severity of the deposits.

If heat is applied, 49-65° C (120-150° F), circulation can be reduced to less than a day, again, depending on the severity of the deposits.

The following supplies are required to perform the cleaning procedure described below:

1. Circulating pump - either electric or air-driven, which would be capable of circulating the water system 1-2 times per hour.

2. Mixing tank. An open end, 120-liter drum, such as Drew™ Chemical Cleaning Circulating Unit (P/C #0948028), or equivalent, is suitable.

3. Steel piping, flexible hoses, fittings and valves as required to perform the job.

IMPORTANT: This should include a vent pipe leading from the top of the engine system to an upper deck area outside of the engine room.

4. Protective clothing for personnel. This includes goggles, rubber gloves, rubber aprons, etc. See Material Safety Data Sheet.

5. Sufficient FERROCLEAN® cleaning treatment to prepare a 10% solution based on the normal water capacity of the system being cleaned.

Cleaning Diesel Engine Cooling Systems (Out of Service)

A. Where possible, connect the discharge side of the circulat-ing pump to the lowest practical point on the diesel cooling system using a length of flexible hose and the appropriate fittings. Using a second section of flexible hose with fit-tings, connect a cleaning solution return with a valve from the highest point on the cooling jacket system to the top of the mixing tank, which is the suction supply for the circulating pump.

B. Add approximately 120 liters (32 U.S. gallons) of fresh water to the tank.

C. Before commencing the cleaning, heat the water in the cooling system until it reaches a temperature of 60-82° C (140-180° F). The heat can be provided by a heating coil or steam line in the cleaning solution mixing tank or a system heat exchanger.

D. Secure the engine. This only applies if the engine had to be run to heat the water.

E. Be sure all valving in the mixing tank, pump, return and vent system are open. Start the chemical circulating pump and adjust the flow rate so that the level of the solution in the mixing tank remains constant.

F. Add sufficient FERROCLEAN cleaning treatment to the mixing tank to prepare the required proportions of cleaning solution based on the water volume in the system. An equal amount of water will need to be drained from the system before adding the FERRO- CLEAN cleaning treatment.

G. Continue circulation and maintain the cleaning solu-tion temperature for a minimum of 12 hours. As the cleaning progresses after adding FERROCLEAN cleaning treatment, the system water may start to change to a dark green/black color. The system pH will drop to 5.0 - 6.0.

H. Drain and flush the system with fresh water. Continue flushing the system with fresh water until the discharge water is completely clear.

I. Inspect the cooling system interior for cleanliness.

Repeat the procedure if the system is not completely clean.

J. Disconnect the vent system and the cleaning system from the engine. Secure all inlet and outlet cleaning points.

K. Fill the engine system with distillate or good quality fresh water and add the correct amount of corrosion inhibitor prior to returning the equipment to service.

NOTE: Should foaming occur during cleaning, we recom-mend the addition of an anti-foam agent. Contact your local Drew Marine representative for further information.

Typical Physical Properties

Appearance: Light yellow liquid Specific Gravity @25° C (77° F): 1.14 Flash Point (PMCC): None Freeze Point: -7.7° C (18° F) pH (neat product): 5.1

Packaging

FERROCLEAN cleaning treatment is available in 25-liter pails (P/C #6675401).

File details come from the government source that posted it. Updated .