associate drawing

View the file

Other files

File Type Posted
0021_A_CLEAN AND GAS FREE TANKS VOIDS AND COFFERDAMS.doc DOC document
10-R-3012 amendment 5.doc DOC document
SM1000-01_A-REV.pdf PDF
SM1000-02_A-REV.pdf PDF
SM1000-03_A-REV.pdf PDF
350-000-01.pdf PDF
1INFORMATION DATA.doc DOC document
10-R-3012 amendment 4.doc DOC document
SM1000_TP.pdf PDF
0109_A_ Bilge Well Preservation.doc DOC document
0021_A_CLEAN AND GAS FREE TANKS VOIDS AND COFFERDAMS.doc DOC document
0003_NSP_ APPROACH BERTH AND MOORING.doc DOC document
10-R-3012 amendment 3.doc DOC document
WI 560 Calcium Carbonate Dosing System.docx DOCX document
GFM List for WI Index Amend 3.xls XLS spreadsheet
References for WI Index T-AKE 9 PSA Amend 2.xls XLS spreadsheet
0003_NSP_ APPROACH BERTH AND MOORING.doc DOC document
10-R-3012 amendment 2.doc DOC document
0622_A_Second Deck Cargo Hold Modifications.doc DOC document
GFM List for WI Index T-AKe 9 PSA Amend 2.xls XLS spreadsheet
WI 501 Ref 2.4 Drew Technical Product Sheet MC-PD-46.pdf PDF
WI 501 Ref 2.5 Drew Removal of Corrosion Products T-AKE.doc DOC document
261-7488730_D 1.DWG DWG drawing
7488748_B.doc DOC document
WI 0561 Senitec OWS Sys Installation.doc DOC document
Ref for WI Index T-AKE 10 PSA Amend 1.xls XLS spreadsheet
0547_A_HP Crossover to EDG Start Air System.doc DOC document
2.7 Attachment 7 Ball Valve Removal Photo.pdf PDF
0617_A_06 Lvl Vent Trunk Door Install.doc DOC document
261-7488730_D 2.DWG DWG drawing
7488951_L.pdf PDF
479-341-7012_--_SRD_Appendix A.DOC DOC document
GFM List for WI Index.xls XLS spreadsheet
8390078 Senitec OWS Installation .pdf PDF
7488736_D Distilled Water Transfer Sys Diagram.pdf PDF
T6435-CM-MMC-010.pdf PDF
261-7488730_D 3.DWG DWG drawing
7488736_D.pdf PDF
529-74 3.DWG DWG drawing
261-8389758 B - Mn Diesel Gen Remote Fuel Isolation Valve Install.pdf PDF
2.2 Attachment 2 471-342-7126_C-SRD_004.dwg DWG drawing
479-341-7012_--_SRD_Appendix D.xls XLS spreadsheet
2.6 Attachment 6 On Line and Recirc Manifold locations photos.pdf PDF
20001700 REV C Transmitter Installation Man.pdf PDF
479-341-7012_--_SRD_Appendix C.DOC DOC document
20002298REV C F-Series Meter Install Manual.pdf PDF
261-7488730_D 5.DWG DWG drawing
529-74 1.PDF PDF
WI 205 FO Meter Replacement.doc DOC document
GFM List for WI Index.xls XLS spreadsheet
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Section Equipment Type Ref. Date Issue Document No. Page 5 Installation Senitec M 1000 Tni /Man 080111 1 91 974 022 00E 1(8)

DELIVERY

InFORMATIOn

Wärtsilä Sweden AB Box 8006 SE-402 77 Göteborg, Sweden Telephone: +46-31 744 46 00 Fax: +46-31 744 46 70

Assembling instructions

These instructions should be followed if the unit has been delivered split in three pieces.

Unit assembly schematics

The unit must be assembled according to below figure:

Pieces 1 and 2 must be assembled together. Piece 3 can either be connected together with 1 and 2 or be installed not farther than 15 meters from 1 and 2.

Note! Piping, electrical cables and hoses must adjusted and in some cases be replaced if piece 3 is not connected together with 1 and 2.

2 (8) 2 Delivery Information – 91 974 022 00E (Issue 1) Wärtsilä Sweden AB

Fixing

The frames must be fixed together with the delivered screws according to below figure

Mount the holding plates between piece 1 and 2 on both sides.

Solids ramp

Assemble the ramp on the flotation tank according to above figure. When as-sembling the ramp, silicone must be used between the ramp and the flotation tank walls (all three sides). Mount the nuts on the inside of flotation tank to fix the ramp.

Wärtsilä Sweden AB 2 Delivery Information – 91 974 022 00E (Issue 1) 3 (8)

Scrape cylinder

Mount the scrape cylinder according to above figure. When mounting the cylinder, make sure that the cylinder is turned the right way.

PPM-meter outlet hose

Connect the outlet hose for the PPM-meter to the flotation tank. Use the upper left lead trough.

Flocculant tank.

4 (8) 2 Delivery Information – 91 974 022 00E (Issue 1) Wärtsilä Sweden AB

Piping

Connect the piping between the pieces according to below figure.

D200 outlet pipe.

Piping

Connect the piping between the pieces according to below figure.

Filter inlet pipe.

Wärtsilä Sweden AB 2 Delivery Information – 91 974 022 00E (Issue 1) 5 (8)

Piping

Connect the piping between the pieces according to below figure.

Water pipe to flotation stage.

Piping

Connect the piping between the pieces according to below figure.

Solids drain pipe.

6 (8) 2 Delivery Information – 91 974 022 00E (Issue 1) Wärtsilä Sweden AB

Pneumatic connections

Roll out and tie up the pneumatic hoses according to below figures. Connect them to matching devices according to appendix for pneumatic drawings.

Back side.

Front side.

Wärtsilä Sweden AB 2 Delivery Information – 91 974 022 00E (Issue 1) 7 (8)

Electrical connections

Roll out and tie up the cables according to below figures. Connect them to matching devices ac-cording to appendix for electrical drawings.

Internal electrical points

Covers

Mount the covers

Covers locations

M205 - Chemical mixer stirrer motor

L401 - Position switch, back

L300 - Dissolved air tank level switch

M500 - Outlet pump D500

M300 - Dissolved air pump D300 16 - Fresh water valve Y001 L500 - Pressure transmitter

300 - Flocculant dosing pump D203 301 - Flocculant stirrer motor Y204 302 - Power supply PPM-meter Q500 303 - Control signals PPM-meter Q500 304 - Low level switch flocculant tank L203 305 - Pressure switch filter P501

M203 M204 L203 P501

CB001

8 (8) 2 Delivery Information – 91 974 022 00E (Issue 1) Wärtsilä Sweden AB

Flocculant dosing hose

Tie up the dosing hose according to below figure and connect the hose to the flocculant valve.

Flocculant dosing valve

Tie up the dosing hose according to below figure and connect the hose to the flocculant dosing pump.

Flocculant pump

File details come from the government source that posted it. Updated .