1717488Amend0006dwg_STRUCTURAL.pdf
PDF 363 KB Posted
- Attached to
- N4008526R0037 P1574/P1591/P1592 MCB CAMP LEJEUNE
- Solicitation number
- N4008526R0037
About this file
This is a structural engineering drawing document that provides typical construction details for concrete slab-on-grade foundations and related structural elements for the 1st Marine Expeditionary Support Facility (OSF) at Camp Lejeune, North Carolina.
The drawing sheet (SB502) contains multiple detail sections illustrating standard specifications for slab-on-grade construction with various reinforcement configurations. Key details include: typical 4" and 6" wire-wire-reinforced (W.W.R.) slab-on-grade details with #4 rebar at 12" on-center spacing; typical 7" reinforced slab-on-grade details; keyed construction joints (KCJ) and control joints (CJ) with specifications for saw-cut widths and depths; discontinuous slab joint details with dowel baskets; doweled construction joints (DCJ); and reentrant corner reinforcement. Additional details specify exterior equipment pad construction with concrete slabs and anchor dowels, housekeeping pad details with embedded wire-wheel fabric, typical shower curb details with #3 rebar at 12" on-center, and site retaining wall details with 3/4" chamfers and specific clearance requirements. All details reference coordination with mechanical, electrical, plumbing, and architectural drawings for precise locations and dimensions. The document is approved by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic and indicates project number P-1574 with construction contract number 12885925.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EQUIPMENT
(NOTE A)
NOTE A:
COORDINATE SIZE AND LOCATION WITH
OTHER DISCIPLINES' DRAWINGS
18" LAP
2 1/2"
F.O. WALL
8"
#4 CONT. AT 8"o/c
HORIZONTAL
#4 AT 12"o/c -
CONCRETE
RETAINING WALL
3 - #4 CONT. TOP
AND BOTTOM
#4 CLOSED LOOP
TIES AT 12"o/c
F.O. CONCRETE
STD. 90° HOOK
VERTICAL
F.O. CONCRETE
3/4" CHAMFER -
EACH SIDE
TOP OF CONCRETE
WALL EL. - SEE
THE CIVIL DWGS.
FINISHED GRADE - SEE
THE CIVIL DWGS. (TYP.)
1'-4"8"
1' -0
1'
-0
M
IN
CONTROL JOINT (CJ)KEYED CONSTRUCTION JOINT (KCJ)
DISCONTINUOUS SLAB JOINT
PLAN AT DEPRESSION
CONTROL JOINT (CJ)
PLAN OF DIAMOND
DOWELS AT SLAB
JOINT INTERSECTION
PLAN OF DOWEL BASKETS AT
SLAB JOINTINTERSECTION
PLAN AT
DISCONTINUOUS SLAB JOINT
REENTRANT CORNER REINFORCEMENTSLAB REINFORCING
FLOOR SINK/DRAIN
DOWELED CONSTRUCTION JOINT (DCJ)
NOT TO SCALE NOT TO SCALE
6"
EACH SIDE OF JOINT
SLOPE AT 1:1
(TYPICAL)
6"
DISCONTINUE 1" CLEAR
W.W.R. - SEE PLAN;
PREVIOUS POUR
SLAB-ON-GRADE
CURING COMPOUND
BEFORE MAKING NEW
POUR
PREVIOUS POUR WITH
PAINT FACE OF
CL OF CONSTRUCTION
JOINT
NEW POUR
DEPRESSION -W.W.R.
SEE PLAN
SLAB-ON-GRADE
DEPTH OF
SAW-CUT WIDTH = 1/4"
SLAB-ON-GRADE
SLAB THICKNESS 'T'
ONE-QUARTER OF
SAW-CUT DEPTH =
CL OF SAW-CUT
JOINT
#4 x 32" LONG, MIDDLE OF
SLAB, CENTER
ON END OF
SLAB JOINT
OR CJ
KCJ
2 1/2" CLR.
THICKNESS 'T'
2 x 'T'
THICKNESS 'T'
THICKNESS 'T'
(TYP.)
DEPRESSION SEE THE ARCH. DWGS.
EXACT SIZE AND LOCATION OF
2 x 'T'
VAPOR RETARDER
(WHERE OCCURS) -
SEE PLAN
VAPOR RETARDER
(WHERE OCCURS) -
SEE PLAN
HARDBOARD OR FIBERBOARD STRIPS.
CONTROL JOINTS USING PREMOLDED PLASTIC,
CONTRACTOR HAS THE OPTION TO FORM
VAPOR RETARDER
(WHERE OCCURS) -
SEE PLAN
2" C
LE
A
R 8" THICK CONCRETE
MAT REINF. WITH
#4 AT 12"o/c, EACH
WAY
4" DEPTH OF #5 STONE SUBBASE8"
12" TURNED DOWN
(MINIMUM) - ADJUST
FOR GRADE
6" MINIMUM
8" (MINIMUM) - DEEPER AS
NEEDED FOR GRADE
APPROXIMATE GRADE
TOP OF CONCRETE MAT
CONT. 3/4" CHAMFER
6"
#4 AT12" ON-CENTER
WITH 135° HOOK
#4 CONT.
SLAB JOINT
ON END OF
SLAB, CENTERED
2" FROM TOP OF
#4 x 32" LONG, 2 1/2" CLR.
OR CJ
DCJ
PNA FLAT BAR DOWEL
BASKET 2 1/2" x 3/8" x 12"
CL CONTROL JOINT
SLAB-ON-GRADE
SAW CUT IS TO BE PERFORMED
AS SOON AS CUT CAN BE MADE
WITHOUT RAVELING CONCRETE.
AT 18"o/c - CENTERED
NOTE: ON JOINT
CL SLAB JOINT
TO CL DIAMOND
12" MAX. (TYP.)
DOWEL = 6" MIN.,
SLAB JOINT
(DJC OR CJ
TYP.)
DIAMOND
(TYP.)
DOWEL
E Q
E
Q
DOWELS NOT
SHOWN - SEE
OTHER
DETAILS
JOINT FILLER
SAW-CUT WIDTH = 1/8"
CL SLAB JOINT
TO END OF DOWEL
BASKET = 9" MAX.
CONTROL
JOINT
(TYP.)
DOWEL
BASKET
(TYP.)
(WHERE SPECIFIED)
VAPOR RETARDER
SLAB THICKNESS 'T'
ONE-QUARTER OF
SAW-CUT DEPTH =
AT LOCATIONS WHERE
NO SLAB JOINT OCCURS:
SLAB
1 1/2" CLR. FROM TOP OF
2 - #4 x 4'-0" LONG SET
3" HOOK
(TYP.)
TYPICAL
FLOOR SINK
OR SQUARE
DRAIN
#4 RE-ENTRANT CORNER
TIES - LOCATE 2" CLEAR
FROM TOP OF SLAB
2" CLEAR FROM CORNER
OF FLOOR OPENING (TYP.)
THIS DETAIL APPLICABLE
THROUGH SLAB AND NO
SLAB JOINT OCCURS
NOTE:
WHERE CMU/CONCRETE
CORNER PROTRUDES
CMU WALL OR
OR CONCRETE
PEDESTAL
SPECIFICATIONS
NEW POUR
E Q
E
Q
PNA 3/8" THICK 4 1/2" SQUARE
JOINT
PREVIOUS POUR
CL CONSTRUCTION
WITH THE MANUFACTURER
NOTE:
PRIOR TO NEW POUR.
COAT FACE OF PREVIOUS
DIAMOND DOWELS AT 18"o/c -
SECURE TO SLAB POUR
BULKHEAD IN ACCORDANCE
2"± DEEP x 1/8"± WIDE
JOINT FILLER - SEE
SPECIFICATIONS
SLAB-ON-GRADE
POUR WITH BOND BREAKER
REINF. - SEE PLAN;
DISCONTINUE 1" CLEAR
EACH SIDE OF JOINT (TYP.)
REINF. - SEE PLAN;
DISCONTINUE 1" CLEAR
EACH SIDE OF JOINT (TYP.)
C4
TYPICAL ADDED REINFORCEMENT SLAB-ON-GRADE DETAILS
NOT TO SCALEC1
TYPICAL 4" AND 6" W.W.R. REINFORCED SLAB-ON-GRADE DETAILS
NOT TO SCALE
C1
TYPICAL 7" REINFORCED SLAB-ON-GRADE DETAILS
NOT TO SCALE
A1
TYPICAL EXTERIOR EQUIPMENT PAD DETAIL
NOT TO SCALE
6"
MIN.
SLAB-ON-GRADE
MECH., ELEC. OR PLUMB. UNIT -
SEE THE MECH. DWGS.
CONC. SLAB - SEE THE MECH.,
1" CHAMFER
2" C
LR
4"
6"
#4 AT 12"o/c
EACH WAY
#4 DOWEL AT
1'-0"o/c MAX.
AROUND PERIMETER -
DRILL AND ANCHOR
WITH EPOXY
F.O. EQUIPMENT
ELEC. OR PLUMB. DWGS. FOR
LOCATIONS AND EXTENTS
A2
HOUSEKEEPING PAD DETAIL
NOT TO SCALE
TYPICAL
3"
E M
B
W.W.F.
3"
E M
B
A3
CURB DETAIL
NOT TO SCALE
TYPICAL SHOWER
4"
CONCRETE CURB - SEE
PLAN AND THE ARCHITECTURAL
DRAWINGS FOR LOCATIONS
AND PLAN DIMENSIONS
#3 AT 12" o/c - DRILL AND
ANCHOR WITH EPOXY
8"
6" 6"
SEE SHEET CG505 FOR LOCATION AND DIMENSIONAL
LAYOUT OF WALL AT SAND FILTER
A4
WALL DETAIL
NOT TO SCALE
TYPICAL SITE RETAINING
3" CLR.
2" CLR.
(TYP.) 0" CLR.0" CLR.
ENGINEERS + SURVEYORS
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S
TE
M S
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
N O
R F
O L
K V
A
AS NOTED
D C
C O
R E
U .S
. M A
R
IN
E C
O R
P S
1717488
C A
M P
L E
JE
U
N E
, N C
P -1
1S T
M R
S B
O P
E R
A
TI
O N
A L
S U
P P
O R
T
FA
C
IL
IT
Y
O
S F)
KDB / SVR
EJA
HPN
KEJ
Approved by Sofia Schwartz, Asset Management Branch Director, PWD G-F, MCIEAST-MCB Camp Lejeune via email
12/18/2025
B
Y A
M E
N D
M E
N T
/2
7/
E
H I
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
/2
/2
:0
:0
P
M
A u to d e s k D o c s /2
.0
P -1
-P
-1
R
D
N
D M
R S
B O
S F
T
U S
C P
A C
/B L
D G
-P
-1
-S .r v t
SB502
TY
P
IC
A
L D
E
TA
IL
S
DWS
12885925
EHI NAA
S B
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
P: 804.464.4111
RICHMOND, VIRGINIA 23294
2821 EMORYWOOD PARKWAY SUITE 300
20.009-J
| Sheets |
| SB502 - TYPICAL DETAILS |
| 2026-03-09T14:19:39-0400 | |
| Norfolk, VA | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
2026-03-09T14:20:20-0400
File details come from the government source that posted it. Updated .