The document is a detailed mechanical equipment schedule for a construction or renovation project, specifically focusing on HVAC and related systems. The schedule provides comprehensive specifications for air handlers, energy recovery units, chillers, boilers, supply diffusers, return/exhaust registers, and pumps from manufacturers like Trane, Cook, Hydrotherm, Krueger, and Bell & Gosset. Key equipment details include air flow rates, electrical specifications, temperature ranges, water flow rates, and specific performance requirements such as UV light and variable frequency drive (VFD) provisions.
The related federal contract opportunity is a Naval Facilities Engineering Command solicitation (N4008525R9023) for BEQ Chiller Repairs at multiple Marine Corps facilities including MCAS New River, Camp Johnson, and Rifle Range. The solicitation is limited to Mechanical MACC Contractors listed on the General Requirements cover page, with specific scope of work and drawings to be referenced. The project involves mechanical system repairs and upgrades, with a focus on chiller infrastructure at Marine Corps installations.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAIR HANDLER SCHEDULE
,YM.
LOCATION FLOOR BLDG.
MFGR
MODEL
AIR FLOW
CHILLED WATER
COIL
ELECTRICAL SUPPLY FAN
OPER. WT.
(LBS)
FILTERS MERV 13
REMARKS
SUPPLY FAN
OSA
CFM
MBH
ENT AIR
LVG AIR
WATER
ROWS
FPI
CFM
ESP
DB
WB
DB
WB
FLOW
6P
ENT
LVG
VOLTAGE
HP
MECH RM. SECOND FLOOR
TRANE M-17
3"
256.1
81.l"F
69.2"F
55.0"F
53.2"F 51.3
GPM
3.13'
45°F
55°F
208-3
YES
PROVIDE WITH UV LIGHT AND VFD
MECH RM. SECOND FLOOR
TRANE M-17
3"
244.6
81.l"F
69.2"F
55.0"F
53.3"F 48.9
GPM
2.92'
45°F
55°F
208-3
YES
PROVIDE WITH UV LIGHT AND VFD
MECH RM. THIRD FLOOR
TRANE M-17
3"
287.7
81.1"F
69.2"F
55.0"F
53.1"F 57.6
GPM
3.81' 45°F 55"F
208-3
YES
PROVIDE WITH UV LIGHT AND VFD
COIL SIZE & GPM BASED ON 100% OSA UPON ERV FAILURE. (OSA ENTERING 91'F db - 81°F wb)
ENERGY RECOVERY UNIT-DEDICATED OSA AHU
,YM.
| LOCATION FLOOR BLDG. |
| MFGR |
MODEL
| AIR FLOW |
| SUMMER |
| WINTER |
| PREHEAT COIL |
| ELECTRICAL |
| OPER. WT. |
(LBS)
FILTERS MERV 13
| SUPPLY FAN |
| EXH FAN |
| OSA IN |
| RA |
| OSA OUT |
| MBH |
| ENT AIR |
| LVG AIR |
| WATER |
| ROWS |
| FPI |
| VOLTAGE |
| FLA |
| MCA |
| MOCP |
| SUP FAN |
| EXH FAN |
| CFM |
| ESP |
| CFM |
| ESP |
| DB |
| WB |
| DB |
| WB |
| DB |
| WB |
| ENT |
| LVG |
| DB |
| WB |
| DB |
| WB |
| FLOW |
| 6P |
| ENT |
| LVG |
| HP |
| HP |
\E�V)
| MECH RM. ATTIC |
| COOK |
OR EQUAL
3/4"
2.0"
91.0
81.0 76.0
50%
76.0
69.2
| 26'F |
| 53.9'F |
| 71.200 |
| 53.9° |
| 39.2' |
| 68.0° |
40% 7.1
GPM
2.13'
TBD
| 208-3 |
| 30.18 |
| 37.73 |
| 60 |
| 3 |
| 5 |
YES
CCHILLER SCHEDULE
;YM.
MFGR. & MODEL No.
SERVICE
LOCATION
TYPE
EVAPORATOR
CONDENSER
POWER
EEFICIENCIES
OPER. WT.
(LBS)
WATER
PD
CAPACITY
WATER
PD
(FT)
FOULING FACTOR
AMBIENT DESIGN
V-PH
MCA
MOCP
KW/TON
EER
FLOW
IN
OUT
GPM
IN
OUT
TRANE CGAM 70
FIRST FLOOR MECH RM
EXTERIOR
AIR COOLED
GPM
54 "F 44 "F
6.3
FT
65.4 TONS
91"F
208-3
354.5
0.98
11.9
SUPPLY DIFFUSER SCHEDULE
UNIT NO.
MANUFACTURER
MODEL
NECK SIZE
FRAME TYPE
RANGE C.F.M.
REMARKS
E9H
KRUEGER (OR EQUAL)
51240 6x6 0-120
PROVIDE AS 4-WAY
DISCHARGE PATTERN UNLESS SHOWN OTHERWISE ON PlANS
E9H
8x8
121-210
10x10
211-330
12x12
331-470
14x14
471-640
16x16
I 641-1000
I
E9
30x16 600-1300
DOUBLE DEFLECTION ADJUSTABLE GRILLE W/ ALUMINUM 08D
BOILER
YM.
MANUFACTURER
& MODEL NO.
FLOOR BLDG.
LOCATION
INPUT
OUTPUT
DOE
SEASONAL EFF
FUEL
GPM
ENT. WATER TEMP.
LVG. WATER TEMP.
WATERd P
OPER. WT.
BURNER ELECTRICAL
BOILER HP
V-PH I AMPS
B
HYDROTHERM KN-4
FIRST FLOOR MECH RM
MECH RM.
399 MBH
349 MBH
92.7
NAT GAS
160'F
180°F
1360 LBS.
120-1
10.6
PROVIDE BOILER WITH
CIRCULATING PUMP 120V-1(ll-60hz B
HYDROTHERM KN-4
FIRST FLOOR MECH RM
MECH RM.
399 MBH
349 MBH
92.7
NAT GAS
160°F 180°F
1360 LBS.
120-1
10.6
PROVIDE BOILER WITH
CIRCULATING PUMP 120V-1(ll-60hz B
HYDROTHERM KN-4
FIRST FLOOR MECH RM
MECH RM.
399 MBH
349 MBH
92.7
NAT GAS
160°F 180'F
1360 LBS.
120-1
10.6
PROVIDE BOILER WITH
CIRCULATING PUMP 120V-1(ll-60hz
NOTES:
1. USE SURFACE MOUNT IN GYP. BOARD CEILING FRAME TYPE 1 SUBSCRIPT "H" WHERE SHOWN DENOTES GYP. BOARD CEILING.
BRETURN/EXHAUST REGISTER SCHEDULE
UNIT NO.
MANUFACTURER
MODEL
NECK SIZE
FRAME TYPE
RANGE C.F.M.
REMARKS
�H
KRUEGER (OR EQUAL)
S580H (SQUARE)
6x6 0-160
3/4" SPACED FIXED BLADE, 35" DEFLECTION
�H
8x8
161-280
1Ox10
281-435
12x12
436-625
E:9H
14x14
626-855
16x16
856-1110
18x18
1111-1800
S580H (RECTANGULAR)
36x16 750-2000
3/4" SPACED FIXED BLADE, 35" DEFLECTION
PUMPS
:YM.
MANUFACTURER & MODEL NO.
FLOW RATE
WATERd P
RPM
ELECTRICAL
OPER. WT. (LBS)
PUMP EFF.
BLDG FLOOR LOCATION
VOLTAGE
HP
IVP\
_2 /
BELL & GOSSET 1510 2 1/288
157 GPM
80 FT
208-3
7.5
74.88
FIRST FLOOR
MECH ROOM
H2IV_P/\
BELL & GOSSET 1510 2 1/288
157 GPM
80 FT
208-3
7.5
74.88
FIRST FLOOR
MECH ROOM
STAND-BY
�_2 /
BELL & GOSSET 1510 1 1 /2"BC
85 GPM
80 FT
208-3 62.27
FIRST FIRST
WITH VFD
�2_/
BELL & GOSSET 1510 1 1/2"BC
85 GPM
80 FT
208-3 62.27
FIRST FLOOR
STAND-BY WITH VFD
H
NOTES:
1. USE SURFACE MOUNT IN GYP. BOARD CEILING FRAME TYPE 1 SUBSCRIPT "H" WHERE SHOWN DENOTES GYP. BOARD CEILING.
2. ALL RETURN AIR GRILLES FOR FAN POWERED BOXES SHALL BE MINIMUM 18X12 FILTER GRILLE WITH FILTERS.s
CONSULTING MECHANICAL ENGINEERS 140 WEST 3RD AVENUE PH.(760)735-8577
ESCONDIDO, CA 92025 FAX(760)735-8578
w- .stueven-eng(neering.com 1 ? 'i 4 -� AS-BUILT z�