Attachment P - Revised Sheet A-002.pdf

PDF 568 KB Posted

Attached to
DESIGN-BID-BUILD, P-347 PERIMETER SECURITY IMPROVEMENTS, PORTSMOUTH NAVAL SHIPYARD, NCTS CUTLER, MAINE
Solicitation number
N4008525R2609
Issued by

About this file

This document is a technical architectural drawing (Sheet A-002) for a Naval Facilities Engineering Systems Command (NAVFAC) project focusing on air barrier details for an Inspection Station at Naval Station Norfolk in Cutler, Maine. The drawing provides comprehensive technical specifications for air barrier components and installation, including detailed sections and notes covering foundation, wall, roof, and penetration air barrier requirements.

The technical drawing includes floor plans, building sections, and wall sections with specific air barrier installation instructions. Key technical details include self-adhering membranes, concrete slab air barrier components, closed cell spray foam insulation, vapor barriers, and specific requirements for sealing roof, floor, and wall penetrations. The drawing is part of the P-347 Perimeter Security Improvements project, associated with contract number N40085-19-D-9008 T008, and dated for improvements on 2/26/25, with the most recent revision on 5/19/2025.

View the file

Other files

File Type Posted
Attachment O - Revised Sheet A-302.pdf PDF
N4008525R2609 Amendment 0009.pdf PDF
N4008525R2609 Amendment 0008.pdf PDF
Attachment M - Statement_of_Special_Inspections 03-20-2025.pdf PDF
Attachment N - Schedule of Special Inspections.pdf PDF
Attachment L - Schedule of Special Inspections 2024.pdf PDF
N4008525R2609 Amendment 0007.pdf PDF
N4008525R2609 Amendment 0006.pdf PDF
N4008525R2609 Amendment 0005.pdf PDF
N4008525R2609 Amendment 0004.pdf PDF
N4008525R2609 Site Visit Log.pdf PDF
Price Proposal Form - Rev 1.pdf PDF
N4008525R2609 Amendment 0003.pdf PDF
N4008525R2609 Amendment 0002.pdf PDF
N4008525R2609 Amendment 0001.pdf PDF
DD5512 Form.pdf PDF
Time Sensitive - Access Instructions - Cutler P-347 Site Walk.pdf PDF
Time Sensitive - Access List - Cutler Site Walk.xlsx XLSX spreadsheet
Attachment F - Past Performance Questionnaire.pdf PDF
Attachment D - Price Proposal Form.pdf PDF
Attachment C - PIEE Vendor Access Instructions.pdf PDF
Attachment K - JA Interior Finishes Redacted.pdf PDF
Attachment G - Historical Small Business Utilization.pdf PDF
Attachment A1 - Work Order 1663840 1.pdf PDF
Attachment A4 - Work Order 1663840 4.pdf PDF
Attachment A2 - Work Order 1663840 2.pdf PDF
Attachment A - Specifications.pdf PDF
Attachment A5 - Work Order 1663840 5.pdf PDF
Attachment A3 - Work Order 1663840 3.pdf PDF
Attachment E - Construction Experience Project Data.pdf PDF
Attachment B -Pre-Proposal Inquiry Log.xlsx XLSX spreadsheet
Attachment I - Small Business Subcontracting Plan.pdf PDF
Attachment H - Small Business Participation Commitment.pdf PDF
Attachment J - Contractor Exempt Purchase Certificate.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MECH

BREAKROOM

STOR/JAN

CORR

RESTROOM

STORAGE

WAITING

INSPECTION OFFICE

C1

A-002

C1

A-002

RFI/SECURE ROOM

COMM

ELEC

OFFICE

OFFICE

FINISH FLOOR

0' - 0"

TOP OF MASONRY

10' - 8"

CORR

INSPECTION OFFICE

A-002

A4

A-002

A3

OFFICE

COMM

MECH

AB3

FINISH FLOOR

0' - 0"

TOP OF MASONRY

10' - 8"

AB1

AIR BARRIER COMPONENT -

SELF ADHERING MEMBRANE

AT UNDERSIDE OF CONCRETE

SLAB

AIR BARRIER COMPONENT -

CONCRETE SLAB

AIR BARRIER COMPONENT -

SHEET-APPLIED AIR/WATER

RESISTIVE BARRIER

AIR BARRIER COMPONENT -

SELF-ADHERED MEMBRANE

MECH

AIR BARRIER COMPONENT -

CLOSED CELL SPRAY FOAM

INSULATION AT UNDERSIDE

OF SOFFIT

10 MIL POLY VAPOR

BARRIER

FINISH FLOOR

0' - 0"

TOP OF MASONRY

10' - 8"

AB1

AB2

INSPECTION OFFICE

AIR BARRIER COMPONENT -

SHEET-APPLIED AIR/WATER

RESISTIVE BARRIER

AIR BARRIER COMPONENT -

CONCRETE SLAB

AIR BARRIER COMPONENT -

SELF ADHERING MEMBRANE

AT UNDERSIDE OF

CONCRETE SLAB

AIR BARRIER COMPONENT -

CLOSED CELL SPRAY FOAM

INSULATION AT UNDERSIDE

OF SOFFIT

10 MIL POLY VAPOR

BARRIER

1. 5/8" COVER BOARD ROOF SHEATHING

2. PRE-MOLDED PIPE FLASHING SET IN FLASHING CEMENT

3. STAINLESS STEEL CLAMPING RING

4. SELF-ADHERING MEMBRANE

5. CONTINUOUS BEAD OF SELANT AROUND CLAMPING RING

6. RIGID INSULATION

ROOF PENETRATIONS @ STANDING SEAM METAL ROOF

1. 5/8" COVER BOARD ROOF SHEATHING

2. RIGID INSULATION

3. SELF-ADHERING MEMBRANE

4. 1/4" GLASS-MAT ROOF BOARD

5. STANDING SEAM METAL DECK

AB3 - RIDGE DETAIL @ STANDING SEAM METAL RIDGE

1. SELF-ADHERED MEMBRANE ADHERED TO 5/8" COVER BOARD SHEATHING

@ SLOPED ROOF

2. SELF-ADHERING MEMBRANE CONTINUES AROUND EDGE OF SOFFIT TO

BENT PLATE. SPRAY APPLIED CLOSED CELL INSULATION FROM BENT

PLATE TO UNDERSIDE METAL DECK TO THE INTERSECTION WITH

EXTRUDED POLYSTYRENE RIGID INSULATION ON EXTERIOR WALL

CONSTRUCTION

AB2 - EAVE DETAIL @ STANDING SEAM METAL ROOF

1. MEMBRANE OVER ROCK SELF-ADHERES TO TOP AND SIDE OF FOOTING

2. 10 MIL POLY VAPOR BARRIER UNDER SLAB

AB1 - FOUNDATION DETAILS

A. FOR AIR/MOISTURE BARRIER SYSTEM AND TESTING REQUIREMENTS,

REFER TO SPECIFICATION SECTION 07 27 10.00 10.

B. SEAL ALL ROOF, FLOOR AND WALL PENETRATIONS OR ANY RESIDUAL

OPENING WITH SPRAY FOAM INSULATION CONFORMING TO ASTM E84.

C. DRAWINGS ON THIS SHEET ARE FOR DIAGRAMMATIC PURPOSES ONLY.

D. SELF-ADHERING AIR BARRIER MUST EXTEND 6" AROUND ALL WALL

PENETRATIONS, OPENINGS AND LOCATIONS INDICATED TO SEAL JOINTS

BETWEEN AIR BARRIER MATERIALS.

E. ALL JOINTS AT OPENINGS, TRANSITIONS BETWEEN DIFFERENT MATERIALS

AND PENETRATIONS MUST BE SEALED AS INDICATED.

F. THE ENCLOSURE SURFACE AREAS LISTED ON THESE DRAWINGS ARE

APPROXIMATE FOR THE EXTERIOR WALL (INCLUDING FENESTRATION,

GLAZING, LOUVERS AND DOORS), ROOF AREA AND GROUND FLOOR SLAB.

THE SURFACE AREAS LISTED INCLUDES THE GROSS EXTERIOR SURFACE

OF THE ENCLOSURE AND NO DEDUCTIONS WERE MADE FOR WALL

PENETRATIONS, AIR INTAKES, EXHAUST LOUVERS, MAKE-UP AIR INTAKES,

PRESSURE RELIEF DAMPERS OR ANY OTHER INTENTIONAL HOLES. THIS IS

NOT INCLUDED IN THE AIR BARRIER DESIGN OR CONSTRUCTION.

FENESTRATION IS INCLUDED IN THE AIR BARRIER ENCLOSURE

CALCULATIONS. TESTING COMPANY MUST VERIFY THAT THE AREAS

LISTED MATCH AS-BUILT CONDITIONS AND THAT THE TOTAL SURFACE

AREA OF THE ENCLOSURE IS CORRECT.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 14 SEP 2023

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O

LK

, V A

AS NOTED

LA

Y

O U

T N

A M

E

P L

O T

T E

D

U S

E R

5/

/2

6:

:1

P M

A-002

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IN

S

P E

C

TI

O N

S

TA

TI

O

N

A

IR

B A

R R

IE

R

WAT

12880969

WAT TRH

2/26/25

IM

P

R O

V E

M E

N

TS

MRI/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DJD

HPN

M

ID

LA

N

T D

C C

O R

E

A -0 th en d er so n

187 267

SCALE: 1/8" = 1'-0" (A-002)

A1

INSPECTION STATION - AIR BARRIER FLOOR PLAN

SCALE: 1/8" = 1'-0" (A-002)

C1

INSPECTION STATION - AIR BARRIER BUILDING SECTION

SCALE: 1/2" = 1'-0" (A-002)

A4

INSPECTION STATION - AIR BARRIER WALL SECTION

SCALE: 3/4" = 1'-0" (A-002)

A3

INSPECTION STATION - AIR BARRIER WALL SECTION

AIR BARRIER DESCRIPTION NOTES GENERAL SHEET NOTES

4' 8' 16'0' 1/8" =1'-0"

1' 2' 4'0' 1/2" =1'-0"

0' 1' 2' 3' 3/4" =1'-0"

DASHED LINE REPRESENTS GRAPHICALLY THE AIR

BARRIER CONTINUOUS CONNECTIONS AND IS FOR

ILLUSTRATIVE PURPOSES ONLY. THE MATERIAL AT

THE FOUNDATION AND FOOTING ARE NOT MEANT

TO CONTINUE UNDER THE FOUNDATION WALL AND

TOP OF FOOTING, BUT RATHER AN ILLUSTRATION

INDICATING THE CONTINUITY OF THE AIR BARRIER.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

O M

M E

N T

P

P I

/1

9/

File details come from the government source that posted it. Updated .