Attachment M - Statement_of_Special_Inspections 03-20-2025.pdf
PDF 108 KB Posted
- Attached to
- DESIGN-BID-BUILD, P-347 PERIMETER SECURITY IMPROVEMENTS, PORTSMOUTH NAVAL SHIPYARD, NCTS CUTLER, MAINE
- Solicitation number
- N4008525R2609
About this file
The Statement of Special Inspections document is for the P-347 Anti-Terrorism Perimeter Security/Entry Control Point project located in Cutler, ME. The project has a Seismic Design Category of B, Risk Category II, with a design wind speed of 109 mph, one story, and a structure height of 21 feet. The document details the Lateral Force Resisting System (LFRS) elements, which include Structural Steel Moment Frames and Ordinary Reinforced Masonry Shear Walls for both the canopy and inspection building, with specific focus on the Metal Roof Deck and Related Fastening System.
The document indicates that a Special Inspector of Record (SIOR) is NOT required per UFGS 01 45 35, Section 1.3.8. Additionally, the project does not have Designated Seismic Systems (DSS) due to the Seismic Design Category being less than C. The Special Inspector is instructed to carefully inspect the critical main wind/seismic force resisting systems as part of their roles and responsibilities, referencing the Schedule of Special Inspections for inspection checklists.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project:
Location:
Project #:
Date:
B
II
No
Statement of Special Inspections Page 1 of 2
Canopy and Inspection Building
Horizontal LFRS Elements Notes
Metal Roof Deck & Related Fastening System
Canopy
Inspection Building
Following is a listing of critical main wind/seismic force resisting systems for this structure. Carefully inspect these elements as part of the roles and responsiblities of the Special Inspector (reference the Schedule of Special Inspections for inspection checklists).
Lateral Force Resisting System (LFRS)
2018 IBC 1704.3.2 and 1704.3.3
Vertical LFRS Elements Notes
Structral Steel Moment Frames
Ordinary Reinforced Masonry Shear Walls
Hazardous Occupancy or attached to such?
STATEMENT OF SPECIAL INSPECTIONS
Special Inspector of Record (SIOR)
A Special Inspector of Record (SIOR)
SIOR Name (Registered Professional):
Professional Registration Number:
Consulting Firm Name (if any):
SIOR Office AND Mobile Phone Number:
IS NOT
Group H Occupancies required (per UFGS 01 45 35, Section 1.3.8)
John Doe P.E.
C222222
ABC Structural Consulting
1234567895 (Mobile), 123456789 (Office)
P-347 Anti-Terrorism Perimeter Security/Enty Control Point
Cutler, ME
1614700
3/10/2025
Project Seismic Design Category:
Project Risk Category:
Project Design Wind Speed (mph):
Number of Stories:
Structure Height Above Grade (ft):
Project:
Location:
Project #:
Date:
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3/10/2025
1614700
Cutler, ME
P-347 Anti-Terrorism Perimeter Security/Enty Control Point
Designated Seismic Systems (DSS)
DSS Component XX
Final Walk Down Inspection and Report
(UFC 3 301 01 SECTION 2-5.4)
Final Walk Down Inspection of non-structural Designated Seismic Systems does not apply to this project (no
Designated Seismic Systems)
Final Walk Down Report, Prepared by the Registered Design Professional in Responsible Charge, Must Include:
1. Record observations of Final Walk Down Inspection
2. Document that Inspections were performed in accordance with the Schedule of Special Inspections
3. Document that all Designated Seismic Systems are installed according to construction/manufacturer document requirements, and that Compliance Certificates have been collected (UFC 03 301 01, 3-6.2, 13.2.2.2).
Statement of Special Inspections Page 2 of 2
DSS Gas lines and associated fittings, anchorage, & flexible Connections
DSS Component XX
DSS Component XX
DSS Component XX
DSS Component XX
DSS Component XX
(2018 IBC 1705.13.3) (ASCE 7-16, 13.2.2, C13.2.2) (UFC 3-301-1, 2-5.3)
DESIGNATED SEISMIC SYSTEMS DO NOT APPLY TO THIS PROJECT, due to the Seismic Design Category being less than C.
ELECTRICAL Designated Seismic Systems (DSS) Requiring a Certificate of Compliance
If additional space is required, append an additional sheet listing the remaining DSS
If additional space is required, append an additional sheet listing the remaining DSS
DSS Emergency or Standby Power System
DSS Component XX
DSS Component XX
DSS Component XX
DSS Component XX
MECHANICAL/PLUMBING Designated Seismic Systems (DSS) Requiring a Certificate of Compliance
OTHER Designated Seismic Systems (DSS) Requiring a Certificate of Compliance
DSS Building egress stair systems
DSS Building fire sprinkler systems
DSS Component XX
DSS Component XX
DSS Component XX
File details come from the government source that posted it. Updated .