About this file

This document package includes construction drawings and specifications for a federal solicitation. The solicitation is for a design-bid-build project to replace the French Creek Ambulatory Care Clinic at Camp Lejeune, North Carolina. The Naval Facilities Engineering Command is seeking bids for general construction, mechanical, electrical and plumbing work. Submissions are due by the date specified in solicitation number N4008521R2524. The construction drawings provide details for mechanical systems, including piping diagrams for air handling units, fan coil units, reheat coils and related components. Specific equipment, products and installation requirements are delineated.

View the file

Other files

File Type Posted
N4008521R2524P00006.pdf PDF
AMEND 06 ATTACHMENT E PRICE PROPOSAL FORM.docx DOCX document
AMD 5 ATTACH 2 Site Visit 6.17.21.pdf PDF
AMD 5 ATTACH 1 P4040 PPIs VER2.xlsx XLSX spreadsheet
N4008521R2524P0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003 Attachment (1) NC20210038 WGDET.pdf PDF
Amendment 0003 Attachment (2) PPIs.xlsx XLSX spreadsheet
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Interim MCMH French Creek_Drawing Set_Compiled.pdf PDF
Amendment 0001 Continuation Sheet.pdf PDF
N4008521R2524P00001.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
1430035dwg10of20_Architectural.pdf PDF
1430035dwg06of20_Civil.pdf PDF
1430035dwg15of20_FireSup.pdf PDF
1430035dwg20of20_Comm.pdf PDF
1430035dwg19of20_Electrical.pdf PDF
ATTACHMENT E PRICE PROPOSAL FORM.docx DOCX document
ATTACHMENT D SMALL BUSINESS SUBCONTRACTING PLAN.docx DOCX document
1430035spc01of03.pdf PDF
1430035dwg02of20_LifeSafety.pdf PDF
RFP N4008521R2524.pdf PDF
1430035dwg16of20_FireAlarm.pdf PDF
1430035dwg07of20_Landscape.pdf PDF
1430035dwg09of20_Architectural.pdf PDF
1430035dwg12of20_Architectural.pdf PDF
1430035dwg04of20_Hazmat.pdf PDF
Attachment A - PPI Inquiry Log.xls XLS spreadsheet
1430035dwg14of20_Equipment.pdf PDF
1430035spc02of03.pdf PDF
1430035dwg13of20_Interiors.pdf PDF
ATTACHMENT C Past Performance Questionnaire.pdf PDF
1430035dwg11of20_Architectural.pdf PDF
1430035dwg05of20_Borings.pdf PDF
1430035dwg03of20_Phasing.pdf PDF
1430035spc03of03.pdf PDF
1430035dwg08of20_Structural.pdf PDF
1430035dwg17of20_Plumbing.pdf PDF
1430035dwg01of20_General.pdf PDF
1430035dwg18of20_Mechanical.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COIL - TYP.

PRESS/TEMP

TEST PORT - TYP.

THERMOMETER - TYP.

32 TO 240°F.

AIR

FLOW

MANUAL AIR VENT W/CAP

3/4" RISER DRAIN AT

BOTTOM OF LOWEST

STACKED COIL - TYP.

TWO-WAY

CONTROL VALVE

1/4" CAGE COCK

W/ CAP - TYP

ISOLATION BUTTERFLY

VALVE - TYP.

PIPE

UNION - TYP

NOTES:

1. INSTALL PIPING TO ALLOW REMOVAL OF COIL FROM UNIT WITH MINIMUM DISRUPTION OF PIPING.

2. PIPE SUPPLY/RETURN IN COUNTERFLOW CONFIGURATION TO AIRFLOW.

3. PROVIDE SHUTOFF VALVES, BALANCING VALVES, AND PRESS/TEMP TEST PORTS FOR EACH AHU CHILLED

WATER COIL AND HOT WATER COIL.

MANUAL BALANCING VALVE. PROVIDE

MINIMUM LENGTHS OF STRAIGHT PIPE UP

AND DOWN STREAM OF FLOW BALANCING

VALVES PER MANUFACTURER

RECOMMENDATIONS - TYP.

M

COOLING COIL

DRAIN PAN

C H

W S

HEATING COIL

C H

W R

H W

S

H W

R

PRESS/TEMP

TEST PORT - TYP.

3/4" HOSE

END DRAIN VALVE - TYP.

TWO-WAY

CONTROL

VALVE

NOTES:

1. LOCATE ALL VALVING WITHIN CABINET. ALL

CHWS/CHWR VALVING SHALL BE OVER DRAIN PAN.

2. DELETE HEATING COIL REQUIREMENTS FOR

COOLING-ONLY FAN COIL UNITS.

CONDENSATE

TRAP

M

MANUAL

BALANCING

VALVE - TYP.

MANUAL BALANCING VALVE

FITTING ON ANY OTHER PIPELINE ACCESSORY - TYPICAL

PROVIDE MINIMUM LENGTH OF STRAIGHT PIPING

UP AND DOWNSTREAM OF VALVE

RECOMMENDED BY VALVE MANUFACTURER

1. PROVIDE FOR ALL AIR TERMINAL VALVES RE-HEAT COILS.

2. INSTALL PIPING TO ALLOW EQUIPMENT WITH A MINIMUM

DISRUPTION OF PIPING.

PRESS/TEMP

TEST PORT - TYP.

MANUAL AIR VENT

W/ CAP

NOTES:

TWO-WAY

CONTROL VALVE

3/4" HOSE

END DRAIN

PIPE UNION

ISOLATION BALL VALVE - TYP.

HWS

HWR

AIR

FLOW

M

PRESS/TEMP

TEST PORT - TYP.

MANUAL

BALANCING

VALVE - TYP.

AUTOMATIC AIR VENT

AUTOMATIC AIR VENT

(SUPPORT INDEPENDENT

OF PIPING)

1/2"

6"

MIN 12"

LENGTH

MANUAL AIR VENT

OPEN END

FUNNEL

D

EXTEND TO

APPROVED

LOCATION

3/8"

3/8" BALL

VALVE

REDUCER

PIPE

NOTE:

FOR AIR TERMINAL UNIT REHEAT COIL CONNECTIONS TERMINATE DRAIN

A MINIMUM OF 12" ABOVE CEILING FOR MAINTENANCE ACCESS.

PIPE

48" MAXIMUM

5 GAL.

TANK

UNION PUMP

DISCHARGE

PIPING

PUMP

SUCTION

PIPING

3/4" WATER

SAMPLING POINT

WITH HOSE

CONNECTION

FLOOR

3/4" DRAIN PIPE

TO FLOOR DRAIN

BALL VALVE

D

PROVIDE DOUBLE NUTS

WITH WASHERS - CAULK

BASE OF PENETRATION - TYPICAL.

0.25" THREADED BRASS

NIPPLE W/LOCKNUTS &

CAP, TYPICAL.

FLOOR

CONDENSATE NEUTRALIZATION

KIT BY BOILER MANUFACTURER

EXTEND 3/4" TO

FLOOR DRAIN 1/2"

BOILER

12"

LOCATE 40"

ABOVE BOILER

DISCHARGE FLUE

BOILER DISCHARGE STACK

AIR COOLED

CONDENSING UNIT

STOP VALVE - TYPICAL

ROOF

EQUIPMENT

SUPPORT- TYPICAL

PIPE PORTAL

ROOF CURB

LIQUID LINE

FILTER/DRYER

SCHRAEDER ACCESS

FITTING - TYPICAL

CONDENSATE

P-TRAP

EXTEND TO

CONDENSATE

DRAIN SYSTEM

DUCTLESS SPLIT

SYSTEM REFRIGERANT

COIL AND DRAIN PAN

No 71574

STATE OF

ND

N O

SB

A RE

O

C A

J

P R

O F

N S

S

OI

E

LA ENG

IN

E E

R

LICENSE

F

LORI DA

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

IO

N

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

B

IM

- M ed ic al

C lin ic R ep la ce m en t F re nc h C re ek

/4

0- B

LD

G

-1

-M _R

.rv t

4/

/2

:3 6:

P

M

As indicated

P

IP

IN

G

D E

T A

IL

S

MP501

BEF LMN JAA

12760713

11/18/20

SCALE: NOT TO SCALE

A5

AHU COIL DIAGRAM W/ 2-WAY VALVE

SCALE: NOT TO SCALE

A2

FAN COIL UNIT PIPING DIAGRAM - HTG. AND CLG.

SCALE: NOT TO SCALE

D3

MANUAL BALANCING VALVE

SCALE: NOT TO SCALE

A3

REHEAT COIL PIPING

SCALE: NOT TO SCALE

B5

AIR VENT

SCALE: NOT TO SCALE

D5

CHEMICAL SHOT FEEDER

SCALE: NOT TO SCALE

B4

BOILER AND WATER HEATER STACK

SCALE: NOT TO SCALE

B2

DUCTLESS SPLIT REFRIGERANT PIPING SYSTEM

ALG

A m en d m en t 0

/0 9/

2 1

Sheets
MP501 - PIPING DETAILS

File details come from the government source that posted it. Updated .