1430035dwg03of20_Phasing.pdf
PDF 1 MB Posted
- Solicitation number
- N4008521R2524
About this file
This document package includes construction phasing plans and a solicitation for a design-bid-build construction project.
The construction phasing plans outline a four-phase plan for renovations and additions to the French Creek Ambulatory Care Clinic at Camp Lejeune, North Carolina. Phase 1 involves building an addition, with Phase 2 renovating the existing medical clinic. Phase 3 includes miscellaneous infrastructure work and replacing storefronts. Phase 4 covers remaining civil and site work. The plans provide details on installing temporary partitions, maintaining building systems, infection control protocols, and sequencing work between phases.
The solicitation is issued by the Naval Facilities Engineering Command for the construction project described in the plans. Offerors are sought to provide design and construction services. The anticipated award date is March 2022, with work to be completed within 730 calendar days of award. The total projected cost is between $10-15 million. The solicitation includes standard federal clauses and provides instructions for preparing and submitting proposals by the January 2022 closing date.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTROL / RECORDS
x117
ORAL DIAG SUPV
x115
GEN DTR
x122
TEAM DTR
x134
CORR
x140
GEN DTR
x135
TEAM DTR
x136
CONSULT
x137
GEN DTR
x138
GEN DTR
x139
CONSULT
x132
GEN DTR
x133
CORR
x142
FEC
FEC
FEC
FEC
PHASE 1
ADDITION
PHASE 1
ADDITION
EXISTING
MEDICAL CLINIC
EXISTING
DENTAL CLINIC
4 5
6 7 7
PHASE 1:
BUILDING ADDITION
PHASE 2:
EXISTING BUILDING RENOVATION
PHASE 3:
MISCELLANEOUS INFRASTRUCTURE WORK ON THE DENTAL CLINIC
PHASE 4:
CIVIL / SITE WORK
(REFER TO SHEET C-007 FOR CIVIL / SITE WORK PHASING)
IROLFF
A R C H
I T E
C
R E
G I S
T E R E D
AR0011911
D
S
TA TE O
AD
T
A
V
W. B O
L D
T
DI
KEY NOTES 00
KEYPLAN
KEYPLAN
KEYPLAN
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
NPROJECT
NORTH
KEYPLAN
KEYPLAN
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
F R
E N
C H
C R
E E
K A
M B
U
LA
T O
R Y
C A
R E
C
LI
N
IC
A D
D
IT
IO
N
A
LT
E
R A
T
IO
N
V
IR
G
IN
IA
A V
E N
U E
JA
C
K S
O N
V
IL
LE
, N
C
N O
R F
O
LK
, V
IR
G
IN
IA
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
, A T
LA
N
T
IC
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
D
M A
R
IN
E C
O R
P S
B A
S E
C A
M P
L E
JE
U
N E
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1430035
DRAWFORM REVISION: 10 MARCH 2009
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
FOR OFFICIAL USE ONLY
4750 New Broad Street
Orlando, Florida 32814 www.rlfae.com
LICENSE #AA C000564 #EB 0000629
TBD
JGG / RSF
EJA
Approved by JOANNE KRAUSE, Director of Medical Facilities
Program Office, via Email
C :\U se rs
\m ec
\D oc um en ts \4
0-
B
LD
G -1
-P
H _r
_m ec rlf ae
.c om
.rv t
/2
9/
:4 1:
P
M
1/16" = 1'-0"
C O
M P
O S
IT
E
P H
A S
IN
G
P
LA
N
P H
A S
E
PH101
TJH MEC CTR
12760427
11/18/20
SCALE: 1/16" = 1'-0" B4
COMPOSITE PLAN - PHASE 1
A REFER TO SHEETS GI010 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL
SYMBOLS.
B REFER TO DRAWING SERIES AD FOR DEMOLITION NOTES AND PLANS.
C REFER TO HAZARDOUS MATERIAL REPORT, DRAWINGS, AND SPECIFICATIONS
PRIOR TO DEMOLITION.
D REFER TO CIVIL DRAWINGS FOR CIVIL/SITE WORK PHASING PLANS AND NOTES.
E REFER TO PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS FOR ADDITIONAL
PHASING INFORMATION.
F THE PLAN ON THIS SHEET IS SHOWN FOR DIAGRAMMATIC AND PHASING
PURPOSES ONLY. DO NOT SCALE OR OTHERWISE USE TO TAKE-OFFS.
G REFER TO PROJECT SCHEDULE FOR SPECIFIC REQUIREMENTS AND/OR
INFORMATION PERTINENT TO THE FOUR (4) PRIMARY AREAS OF THIS PROJECT:
PHASING NOTES:
ICRA NOTES:
I PRIOR TO COMMENCEMENT OF CONSTRUCTION INSTALL INTERIOR TEMPORARY PARTITIONS TO PREVENT DUST
POLLUTION OF SURROUNDING AREAS. PROVIDE PARTITIONS IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS REQUIREMENTS AND AS REQUIRED BY THE OWNER AND CONSTRUCTION PHASING PLANS. IF A DOOR IS SHOWN, PROVIDE A 20 MIN, SOLID CORE TEMPORARY DOOR WITH CLOSER AND LATCHING. FOR INTERIOR
TEMPORARY PARTITIONS, USE PARTITION TYPE "T" AS SPECIFIED ON SHEET AE802.
J TEMPORARY PARTITIONS AND BARRIERS TO REMAIN UNTIL ALL THE WORK IS COMPLETED AND/OR APPRAVAL IS GRANTED BY THE INFECTION CONTROL OFFICER. UPON REMAVAL OF TEMPORARY PARTITIONS, PREP/PATCH TO
MATCH ADJACENT CONSTRUCTION.
K ENSURE AT ALL TIMES, UNINTERRUPTED HEATING, COOLING, PLUMBING, ELECTRICAL, COMMUNICATION, AND FIRE PROTECTIONS SERVICES WITHIN THE BOUNDARIES OF THE PROJECT SERVING PORTION OF THE FACILITY REMAINING IN SERVICE. COORDIANTE ANY REQUIRED INTERRUPTIONS OF SERVICE WITH THE OWNER TO
MINIMIZE INTERFERENCE WITH OWNER'S OPERATIONS.
L OBTAIN APPROVAL FROM OWNER PRIOR TO SHUTDOWN OF AIR SYSTEMS FOR EQUIPMENT AND DUCTWORK REMOVAL. PROVIDE NOTIFICATIONS PRIOR TO INTENDED ACTION PER THE SPECIFICATIONS AND INCLUDE A LIST
OF SERVICES AFFECTED, SCHEDULE OR WORK, AND PLANNED START DATE.
M ESTABLISH A SEALED AITIGHT PERIMETER PRIOR TO CONTRUCTION. PROVIDE TEMPORARY VENTILATION AND HEPA FILTERS TO MAINTAIN CONSTRUCTION AREA UNDER NEGATIVE PRESSURE TO OCCUPIED AREAS. PROVIDE
TEMPORARY FILTERS AT RETURN GRILLES ADJACENT TO CONSTRUCTION ZONE.
N PROVIDE DIFFERENTIAL PRESSURE MONITORS AT ALL ENTRANCES TO AREAS OF WORK TO CONFIRM NEGATIVE
PRESSURE WITH RESPECT TO NON-CONSTRUCTION AREAS.
O REFER TO MECHANICAL DRAWINGS FOR BALANCING OF EXISTING RETURN REGISTERS TO PRESSURIZE
OCCUPIED SPACES ADJACENT TO CONSTRUCTION ZONE.
A COMPLY WITH THE INFECTION CONTROL PERMIT AND ICRA/PCRA POLICY / PROCEDURES PER CAMP LEJEUNE'S
PRE-CONSTRUCTION RISK ASSESSMENT ICRA/PCRA FORM (EC.02.06.05, LS.01.02.01).
B PROVIDE ONGOING MAINTENANCE AND MONITORING OF PRECAUTIONS FOR INFECTION CONTROL RISK
ASSESSMENT.
C ENSURE FREE AND UNOBSTRUCTED ACCESS TO EMERGENCY DEPARTMENT/SERVICES AND FOR EMERGENCY
RESPONSE PERSONNEL.
D ENSURE FIRE ALARM, DETECTION, AND SUPPRESSION SYSTEMS ARE NOT IMPAIRED. PROVIDE A TEMPORARY, BUT EQUIVALENT SYSTEM, WHEN ANY FIRE SYSTEM IS IMPAIRED.
E ENSURE FREE AND UNOBSTRUCTED EGRESS AND EMERGENCY EGRESS FOR AREAS OCCUPIED DURING CONSTRUCTION AND FOR AREAS UNDER CONSTRUCTION IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS
REQUIREMENTS. PROVIDE SIGNAGE IDENTIFYING ALTERNATE EXISTS AS REQUIRED.
F PROVIDE TMEPORARY LIFE SAFETY LIGHTING AND EXIT LIGHTS IN ACCORDANCE WITH FIRE PROTECTION AND
EGRESS REQUIREMENTS AND AS REQUIRED BY THE OWNER AND CONSTRUCTION PHASING PLANS.
G PROVIDE EXTERIOR TEMPORARY WALLS ARE REQUIRED. EXTERIOR TEMPORARY WALL CONSTRUCTION: 6-INCH METAL STUD WITH (1) LAYER OF EXTERIOR GRADE PLYWOOD (FASTENED PER IBC TABLE 2304.9.1), COVERED BY
(2) LAYERS OF 30 LB. FELT (STAGGER JOINTS WITH 6-INCH OVERLAP), MECHANICALLY FASTENED WITH GALVANIZED NAILS AND DISK CAPS AT 16" O.C. EACH WAY. PROVIDE UNFACED BLANKET INSULATION IN THE STUD CAVITY. PROVIDE (1) LAYER OF 5/8" GLASS MAT FACED GYPSUM BOARD ON THE INTERIOR SIDE.
H PRIOR TO COMMENCEMENT OF CONSTRUCTION SEAL EXISTING DOOR OPENINGS AIR TIGHT, ON EXISTING WALL TO BE USED AS TEMPORARY PARTITIONS, WITH FIRE RETARDANT VISQUEEN BARRIER TAPED TO DOOR FRAME.
1 TEMPORARY PARTITION TO REMAIN THRU THE COMPLETION OF
ADDITION/RENOVATION.
2 CONSTRUCT BRICK CAVITY WALL BASE AND TEMPORARY EXTERIOR WALL,
ROOF STRUCTURAL SUPPORT, AND INSTALL STANDING SEAM METAL ROOF.
REMOVE TEMPORARY WALL PRIOR TO THE INSTALLATION OF THE NEW
STOREFRONT DURING PHASE 3.
3 EXISTING 1-HR FIRE RATED PARTITION TO SERVE AS TEMPORARY PARTITION
THRU THE DURATION OF THE ADDITION/RENOVATION PROJECT. ENSURE
THAT PARTITION EXTENDS TO BOTTOM OF DECK AND ALL PENETRATIONS
ARE PROPERLY SEALED PRIOR TO START OF DEMOLITION/CONSTRUCTION
WORK.
4 PHASE 1A – CONSTRUCT THE ADDITION’S SHELL
5 PHASE 1B – INTERIOR ROUGH INS
6 BLANK OUT EXISTING EXIT SIGN
7 MODIFY EXISTING EXIT SIGN AS SHOWN.
8 SEAL EXISTING DOOR OPENING AIR TIGHT WITH FIRE RETARDANT VISQUEEN
BARRIER TAPED TO DOOR FRAME.
DJD
mec Text Box
DSN
PHASE 1
ADDITION
PHASE 1
ADDITION
PHASE 2
MEDICAL CLINIC
RENOVATION
EXISTING
DENTAL CLINIC
7 8
PHASE 1:
BUILDING ADDITION
PHASE 2:
EXISTING BUILDING RENOVATION
PHASE 3:
MISCELLANEOUS INFRASTRUCTURE WORK ON THE DENTAL CLINIC
PHASE 4:
CIVIL / SITE WORK
(REFER TO SHEET C-007 FOR CIVIL / SITE WORK PHASING)
IROLFF
A R C H
I T E
C
R E
G I S
T E R E D
AR0011911
D
S
TA TE O
AD
T
A
V
W. B O
L D
T
DI
KEY NOTES 00
KEYPLAN
KEYPLAN
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
NPROJECT
NORTH
KEYPLAN
KEYPLAN
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
F R
E N
C H
C R
E E
K A
M B
U
LA
T O
R Y
C A
R E
C
LI
N
IC
A D
D
IT
IO
N
A
LT
E
R A
T
V
IR
G
IN
IA
A V
E N
U E
JA
C
K S
O N
V
IL
LE
, N
C
N O
R F
O
LK
, V
IR
G
IN
IA
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
, A T
LA
N
T
IC
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
R
IN
E C
O R
P S
B A
S E
C A
M P
L E
JE
U
N E
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1430035
DRAWFORM REVISION: 10 MARCH 2009
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
FOR OFFICIAL USE ONLY
4750 New Broad Street
Orlando, Florida 32814 www.rlfae.com
LICENSE #AA C000564 #EB 0000629
TBD
JGG / RSF
EJA
Approved by JOANNE KRAUSE, Director of Medical Facilities
Program Office, via Email
C :\U se rs
\m ec
\D oc um en ts \4
0-
B
LD
G -1
-P
H _r
_m ec rlf ae
.c om
.rv t
/2
9/
:4 1:
P
M
1/16" = 1'-0"
C O
M P
O S
IT
E
P H
A S
IN
G
P
LA
N
P H
A S
E
PH102
TJH MEC CTR
12760428
11/18/20
SCALE: 1/16" = 1'-0" B4
COMPOSITE PHASING PLAN - PHASE 2
A REFER TO SHEETS GI010 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL
SYMBOLS.
B REFER TO DRAWING SERIES AD FOR DEMOLITION NOTES AND PLANS.
C REFER TO HAZARDOUS MATERIAL REPORT, DRAWINGS, AND SPECIFICATIONS
PRIOR TO DEMOLITION.
D REFER TO CIVIL DRAWINGS FOR CIVIL/SITE WORK PHASING PLANS AND NOTES.
E REFER TO PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS FOR ADDITIONAL
PHASING INFORMATION.
F THE PLAN ON THIS SHEET IS SHOWN FOR DIAGRAMMATIC AND PHASING
PURPOSES ONLY. DO NOT SCALE OR OTHERWISE USE TO TAKE-OFFS.
G REFER TO PROJECT SCHEDULE FOR SPECIFIC REQUIREMENTS AND/OR
INFORMATION PERTINENT TO THE FOUR (4) PRIMARY AREAS OF THIS PROJECT:
I PRIOR TO COMMENCEMENT OF CONSTRUCTION INSTALL INTERIOR TEMPORARY PARTITIONS TO PREVENT DUST POLLUTION OF SURROUNDING AREAS. PROVIDE PARTITIONS IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS REQUIREMENTS AND AS REQUIRED BY THE OWNER AND CONSTRUCTION PHASING PLANS. IF A DOOR IS SHOWN, PROVIDE A 20 MIN, SOLID CORE TEMPORARY DOOR WITH CLOSER AND LATCHING. FOR INTERIOR
TEMPORARY PARTITIONS, USE PARTITION TYPE "T" AS SPECIFIED ON SHEET AE802.
J TEMPORARY PARTITIONS AND BARRIERS TO REMAIN UNTIL ALL THE WORK IS COMPLETED AND/OR APPRAVAL IS GRANTED BY THE INFECTION CONTROL OFFICER. UPON REMAVAL OF TEMPORARY PARTITIONS, PREP/PATCH TO
MATCH ADJACENT CONSTRUCTION.
K ENSURE AT ALL TIMES, UNINTERRUPTED HEATING, COOLING, PLUMBING, ELECTRICAL, COMMUNICATION, AND FIRE PROTECTIONS SERVICES WITHIN THE BOUNDARIES OF THE PROJECT SERVING PORTION OF THE FACILITY REMAINING IN SERVICE. COORDIANTE ANY REQUIRED INTERRUPTIONS OF SERVICE WITH THE OWNER TO
MINIMIZE INTERFERENCE WITH OWNER'S OPERATIONS.
L OBTAIN APPROVAL FROM OWNER PRIOR TO SHUTDOWN OF AIR SYSTEMS FOR EQUIPMENT AND DUCTWORK REMOVAL. PROVIDE NOTIFICATIONS PRIOR TO INTENDED ACTION PER THE SPECIFICATIONS AND INCLUDE A LIST
OF SERVICES AFFECTED, SCHEDULE OR WORK, AND PLANNED START DATE.
M ESTABLISH A SEALED AITIGHT PERIMETER PRIOR TO CONTRUCTION. PROVIDE TEMPORARY VENTILATION AND HEPA FILTERS TO MAINTAIN CONSTRUCTION AREA UNDER NEGATIVE PRESSURE TO OCCUPIED AREAS. PROVIDE
TEMPORARY FILTERS AT RETURN GRILLES ADJACENT TO CONSTRUCTION ZONE.
N PROVIDE DIFFERENTIAL PRESSURE MONITORS AT ALL ENTRANCES TO AREAS OF WORK TO CONFIRM NEGATIVE
PRESSURE WITH RESPECT TO NON-CONSTRUCTION AREAS.
O REFER TO MECHANICAL DRAWINGS FOR BALANCING OF EXISTING RETURN REGISTERS TO PRESSURIZE
OCCUPIED SPACES ADJACENT TO CONSTRUCTION ZONE.
A COMPLY WITH THE INFECTION CONTROL PERMIT AND ICRA/PCRA POLICY / PROCEDURES PER CAMP LEJEUNE'S
PRE-CONSTRUCTION RISK ASSESSMENT ICRA/PCRA FORM (EC.02.06.05, LS.01.02.01).
B PROVIDE ONGOING MAINTENANCE AND MONITORING OF PRECAUTIONS FOR INFECTION CONTROL RISK
ASSESSMENT.
C ENSURE FREE AND UNOBSTRUCTED ACCESS TO EMERGENCY DEPARTMENT/SERVICES AND FOR EMERGENCY
RESPONSE PERSONNEL.
D ENSURE FIRE ALARM, DETECTION, AND SUPPRESSION SYSTEMS ARE NOT IMPAIRED. PROVIDE A TEMPORARY, BUT EQUIVALENT SYSTEM, WHEN ANY FIRE SYSTEM IS IMPAIRED.
E ENSURE FREE AND UNOBSTRUCTED EGRESS AND EMERGENCY EGRESS FOR AREAS OCCUPIED DURING CONSTRUCTION AND FOR AREAS UNDER CONSTRUCTION IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS
REQUIREMENTS. PROVIDE SIGNAGE IDENTIFYING ALTERNATE EXISTS AS REQUIRED.
F PROVIDE TMEPORARY LIFE SAFETY LIGHTING AND EXIT LIGHTS IN ACCORDANCE WITH FIRE PROTECTION AND
EGRESS REQUIREMENTS AND AS REQUIRED BY THE OWNER AND CONSTRUCTION PHASING PLANS.
G PROVIDE EXTERIOR TEMPORARY WALLS ARE REQUIRED. EXTERIOR TEMPORARY WALL CONSTRUCTION: 6-INCH METAL STUD WITH (1) LAYER OF EXTERIOR GRADE PLYWOOD (FASTENED PER IBC TABLE 2304.9.1), COVERED BY
(2) LAYERS OF 30 LB. FELT (STAGGER JOINTS WITH 6-INCH OVERLAP), MECHANICALLY FASTENED WITH GALVANIZED NAILS AND DISK CAPS AT 16" O.C. EACH WAY. PROVIDE UNFACED BLANKET INSULATION IN THE STUD CAVITY. PROVIDE (1) LAYER OF 5/8" GLASS MAT FACED GYPSUM BOARD ON THE INTERIOR SIDE.
H PRIOR TO COMMENCEMENT OF CONSTRUCTION SEAL EXISTING DOOR OPENINGS AIR TIGHT, ON EXISTING WALL TO BE USED AS TEMPORARY PARTITIONS, WITH FIRE RETARDANT VISQUEEN BARRIER TAPED TO DOOR FRAME.
ICRA NOTES:
PHASING NOTES:
1 BRICK CAVITY WALL BASE AND TEMPORARY EXTERIOR WALL. REMOVE
TEMPORARY WALL PRIOR TO THE INSTALLATION OF THE NEW STOREFRONT
DURING PHASE 3.
2 TEMPORARY PARTITION FOR PHASE 1 AND PHASE 2. REMOVE TEMPORARY
PARTITION AT THE START OF PHASE 3’S STOREFRONT REPLACEMENT.
3 TEMPORARY PARTITION TO REMAIN THRU THE COMPLETION OF
ADDITION/RENOVATION.
4 EXISTING 1-HR FIRE RATED PARTITION TO SERVE AS TEMPORARY PARTITION
THRU THE DURATION OF THE ADDITION/RENOVATION PROJECT. ENSURE
THAT PARTITION EXTENDS TO BOTTOM OF DECK AND ALL PENETRATIONS ARE
PROPERLY SEALED PRIOR TO START OF DEMOLITION/CONSTRUCTION WORK.
5 PHASE 2 RENOVATION WORK TO BEGIN AFTER THE ADDITION’S SHELL HAS
BEEN CONSTRUCTED AND THE ADDITION’S INTERIOR ROUGH INS HAVE
BEGAN.
6 THE INTERIOR BUILD OUT OF PHASE 1 RUNS CONCURRENTLY WITH PHASE 2
AND PHASE 3.
7 BLANK OUT EXISTING EXIT SIGN
8 SEAL EXISTING DOOR OPENING AIR TIGHT WITH FIRE RETARDANT VISQUEEN
BARRIER TAPED TO DOOR FRAME.
DJDDJD
mec
FEC
FEC
FEC
FEC
FEC
PHASE 1
ADDITION
PHASE 1
ADDITION
PHASE 2
MEDICAL CLINIC
RENOVATION
PHASE 3
DENTAL CLINIC ALTERATIONS
3 4
7 8
7 8
PHASE 1:
BUILDING ADDITION
PHASE 2:
EXISTING BUILDING RENOVATION
PHASE 3:
MISCELLANEOUS INFRASTRUCTURE WORK ON THE DENTAL CLINIC
PHASE 4:
CIVIL / SITE WORK
(REFER TO SHEET C-007 FOR CIVIL / SITE WORK PHASING)
A.
B.
SEE PHASING NOTES ON C-007
SITE / CIVIL PHASES 2C AND 3 TO BE WORKED CONCURRENTLY WITH
INTERIOR WORK IN THE DENTAL CLINIC (PHASE 3 ON THIS SHEET). SITE /
CIVIL PHASE 2C TO BE COMPLETED WITHIN THE SAME 30-DAY TIME PERIOD
AS THE INTERIOR DENTAL CLINIC WORK (SEE KEYNOTE 7).
IROLFF
A R C H
I T E
C
R E
G I S
T E R E D
AR0011911
D
S
TA TE O
AD
T
A
V
W. B O
L D
T
DI
KEY NOTES 00
KEYPLAN
KEYPLAN
KEYPLAN
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
NPROJECT
NORTH
KEYPLAN
KEYPLAN
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
F R
E N
C H
C R
E E
K A
M B
U
LA
T O
R Y
C A
R E
C
LI
N
IC
A D
D
IT
IO
N
A
LT
E
R A
T
V
IR
G
IN
IA
A V
E N
U E
JA
C
K S
O N
V
IL
LE
, N
C
N O
R F
O
LK
, V
IR
G
IN
IA
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
, A T
LA
N
T
IC
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
R
IN
E C
O R
P S
B A
S E
C A
M P
L E
JE
U
N E
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1430035
DRAWFORM REVISION: 10 MARCH 2009
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
FOR OFFICIAL USE ONLY
4750 New Broad Street
Orlando, Florida 32814 www.rlfae.com
LICENSE #AA C000564 #EB 0000629
TBD
JGG / RSF
EJA
Approved by JOANNE KRAUSE, Director of Medical Facilities
Program Office, via Email
C :\U se rs
\m ec
\D oc um en ts \4
0-
B
LD
G -1
-P
H _r
_m ec rlf ae
.c om
.rv t
/2
9/
:4 1:
P
M
1/16" = 1'-0"
C O
M P
O S
IT
E
P H
A S
IN
G
P
LA
N
P H
A S
E
PH103
TJH MEC CTR
12760429
11/18/20
SCALE: 1/16" = 1'-0" B4
COMPOSITE PHASING PLAN - PHASE 3
A REFER TO SHEETS GI010 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL
SYMBOLS.
B REFER TO DRAWING SERIES AD FOR DEMOLITION NOTES AND PLANS.
C REFER TO HAZARDOUS MATERIAL REPORT, DRAWINGS, AND SPECIFICATIONS
PRIOR TO DEMOLITION.
D REFER TO CIVIL DRAWINGS FOR CIVIL/SITE WORK PHASING PLANS AND NOTES.
E REFER TO PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS FOR ADDITIONAL
PHASING INFORMATION.
F THE PLAN ON THIS SHEET IS SHOWN FOR DIAGRAMMATIC AND PHASING
PURPOSES ONLY. DO NOT SCALE OR OTHERWISE USE TO TAKE-OFFS.
G REFER TO PROJECT SCHEDULE FOR SPECIFIC REQUIREMENTS AND/OR
INFORMATION PERTINENT TO THE FOUR (4) PRIMARY AREAS OF THIS PROJECT:
I PRIOR TO COMMENCEMENT OF CONSTRUCTION INSTALL INTERIOR TEMPORARY PARTITIONS TO PREVENT DUST POLLUTION OF SURROUNDING AREAS. PROVIDE PARTITIONS IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS REQUIREMENTS AND AS REQUIRED BY THE OWNER AND CONSTRUCTION PHASING PLANS. IF A DOOR IS SHOWN, PROVIDE A 20 MIN, SOLID CORE TEMPORARY DOOR WITH CLOSER AND LATCHING. FOR INTERIOR
TEMPORARY PARTITIONS, USE PARTITION TYPE "T" AS SPECIFIED ON SHEET AE802.
J TEMPORARY PARTITIONS AND BARRIERS TO REMAIN UNTIL ALL THE WORK IS COMPLETED AND/OR APPRAVAL IS GRANTED BY THE INFECTION CONTROL OFFICER. UPON REMAVAL OF TEMPORARY PARTITIONS, PREP/PATCH TO
MATCH ADJACENT CONSTRUCTION.
K ENSURE AT ALL TIMES, UNINTERRUPTED HEATING, COOLING, PLUMBING, ELECTRICAL, COMMUNICATION, AND FIRE PROTECTIONS SERVICES WITHIN THE BOUNDARIES OF THE PROJECT SERVING PORTION OF THE FACILITY REMAINING IN SERVICE. COORDIANTE ANY REQUIRED INTERRUPTIONS OF SERVICE WITH THE OWNER TO
MINIMIZE INTERFERENCE WITH OWNER'S OPERATIONS.
L OBTAIN APPROVAL FROM OWNER PRIOR TO SHUTDOWN OF AIR SYSTEMS FOR EQUIPMENT AND DUCTWORK REMOVAL. PROVIDE NOTIFICATIONS PRIOR TO INTENDED ACTION PER THE SPECIFICATIONS AND INCLUDE A LIST
OF SERVICES AFFECTED, SCHEDULE OR WORK, AND PLANNED START DATE.
M ESTABLISH A SEALED AITIGHT PERIMETER PRIOR TO CONTRUCTION. PROVIDE TEMPORARY VENTILATION AND HEPA FILTERS TO MAINTAIN CONSTRUCTION AREA UNDER NEGATIVE PRESSURE TO OCCUPIED AREAS. PROVIDE
TEMPORARY FILTERS AT RETURN GRILLES ADJACENT TO CONSTRUCTION ZONE.
N PROVIDE DIFFERENTIAL PRESSURE MONITORS AT ALL ENTRANCES TO AREAS OF WORK TO CONFIRM NEGATIVE
PRESSURE WITH RESPECT TO NON-CONSTRUCTION AREAS.
O REFER TO MECHANICAL DRAWINGS FOR BALANCING OF EXISTING RETURN REGISTERS TO PRESSURIZE
OCCUPIED SPACES ADJACENT TO CONSTRUCTION ZONE.
A COMPLY WITH THE INFECTION CONTROL PERMIT AND ICRA/PCRA POLICY / PROCEDURES PER CAMP LEJEUNE'S
PRE-CONSTRUCTION RISK ASSESSMENT ICRA/PCRA FORM (EC.02.06.05, LS.01.02.01).
B PROVIDE ONGOING MAINTENANCE AND MONITORING OF PRECAUTIONS FOR INFECTION CONTROL RISK
ASSESSMENT.
C ENSURE FREE AND UNOBSTRUCTED ACCESS TO EMERGENCY DEPARTMENT/SERVICES AND FOR EMERGENCY
RESPONSE PERSONNEL.
D ENSURE FIRE ALARM, DETECTION, AND SUPPRESSION SYSTEMS ARE NOT IMPAIRED. PROVIDE A TEMPORARY, BUT EQUIVALENT SYSTEM, WHEN ANY FIRE SYSTEM IS IMPAIRED.
E ENSURE FREE AND UNOBSTRUCTED EGRESS AND EMERGENCY EGRESS FOR AREAS OCCUPIED DURING CONSTRUCTION AND FOR AREAS UNDER CONSTRUCTION IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS
REQUIREMENTS. PROVIDE SIGNAGE IDENTIFYING ALTERNATE EXISTS AS REQUIRED.
F PROVIDE TMEPORARY LIFE SAFETY LIGHTING AND EXIT LIGHTS IN ACCORDANCE WITH FIRE PROTECTION AND
EGRESS REQUIREMENTS AND AS REQUIRED BY THE OWNER AND CONSTRUCTION PHASING PLANS.
G PROVIDE EXTERIOR TEMPORARY WALLS ARE REQUIRED. EXTERIOR TEMPORARY WALL CONSTRUCTION: 6-INCH METAL STUD WITH (1) LAYER OF EXTERIOR GRADE PLYWOOD (FASTENED PER IBC TABLE 2304.9.1), COVERED BY
(2) LAYERS OF 30 LB. FELT (STAGGER JOINTS WITH 6-INCH OVERLAP), MECHANICALLY FASTENED WITH GALVANIZED NAILS AND DISK CAPS AT 16" O.C. EACH WAY. PROVIDE UNFACED BLANKET INSULATION IN THE STUD CAVITY. PROVIDE (1) LAYER OF 5/8" GLASS MAT FACED GYPSUM BOARD ON THE INTERIOR SIDE.
H PRIOR TO COMMENCEMENT OF CONSTRUCTION SEAL EXISTING DOOR OPENINGS AIR TIGHT, ON EXISTING WALL TO BE USED AS TEMPORARY PARTITIONS, WITH FIRE RETARDANT VISQUEEN BARRIER TAPED TO DOOR FRAME.
PHASING NOTES:
ICRA NOTES:
1 TEMPORARY PARTITION TO REMAIN THRU THE COMPLETION OF
ADDITION/RENOVATION.
2 EXISTING 1-HR FIRE RATED PARTITION TO SERVE AS TEMPORARY PARTITION
THRU THE DURATION OF THE ADDITION/RENOVATION PROJECT. ENSURE
THAT PARTITION EXTENDS TO BOTTOM OF DECK AND ALL PENETRATIONS ARE
PROPERLY SEALED PRIOR TO START OF DEMOLITION/CONSTRUCTION WORK.
3 PHASE 3A – REMOVAL AND REPLACEMENT OF STOREFRONT (AT VESTIBULE
AND CORRIDOR EXTENSION AT ADDITION)
4 PHASE 3B – FIRE ALARM, HVAC, AND OTHER MISCELLANEOUS
INFRASTRUCTURE WORK ON THE DENTAL CLINIC.
5 THE INTERIOR BUILD OUT OF PHASE 1 AND PHASE 2 RUN CONCURRENTLY
WITH PHASE 3.
6 SEAL EXISTING DOOR OPENING AIR TIGHT WITH FIRE RETARDANT VISQUEEN
BARRIER TAPED TO DOOR FRAME.
7 ALL WORK WITHIN THE DENTAL CLINIC MUST BE COMPLETED WITHIN 30
CALENDAR DAYS. ALL MATERIALS FOR WORK IN THE DENTAL CLINIC MUST BE
ON SITE PRIOR TO THE START OF THE 30-DAY TIME PERIOD.
8 SEQUENCE OF SITE / CIVIL PHASE WORK WITHIN THE DENTAL CLINIC:
DJD
mec
| PH101 - COMPOSITE PHASING PLAN - PHASE 1 |
| PH102 - COMPOSITE PHASING PLAN - PHASE 2 |
| PH103 - COMPOSITE PHASING PLAN - PHASE 3 |
| 2021-01-08T11:03:43-0500 | |
| Orlando, FL | |
| David Boldt | |
| I am signing to certify the authenticity of this document. |
| 2021-01-08T11:04:12-0500 | |
| Orlando, FL | |
| David Boldt | |
| I am signing to certify the authenticity of this document. |
| 2021-01-08T11:04:12-0500 | |
| Orlando, FL | |
| David Boldt | |
| I am signing to certify the authenticity of this document. |
| 2021-01-16T16:16:43-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2021-01-16T16:17:26-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2021-01-16T16:17:33-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2021-01-16T16:17:59-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2021-01-16T16:18:18-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2021-01-16T16:18:18-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |