About this file

This document package includes hazardous materials abatement general notes and a hazardous materials floor plan for a Design-Bid-Build construction project for the P4040 French Creek Ambulatory Care Clinic at Camp Lejeune, North Carolina. The project involves abatement of asbestos-containing materials including black mastic associated with floor tile covering approximately 12,800 square feet. Additional hazardous materials include lead-based paint on components such as a fire line tee fitting and x-ray room partitions and doors, as well as universal wastes like fluorescent lamps and ballasts containing PCBs throughout the facility and mercury in thermometers in mechanical rooms. Offerors must comply with regulatory notification requirements and abatement standards from the North Carolina Asbestos Hazard Management Program, OSHA, and EPA.

View the file

Other files

File Type Posted
N4008521R2524P00006.pdf PDF
AMEND 06 ATTACHMENT E PRICE PROPOSAL FORM.docx DOCX document
AMD 5 ATTACH 2 Site Visit 6.17.21.pdf PDF
AMD 5 ATTACH 1 P4040 PPIs VER2.xlsx XLSX spreadsheet
N4008521R2524P0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003 Attachment (1) NC20210038 WGDET.pdf PDF
Amendment 0003 Attachment (2) PPIs.xlsx XLSX spreadsheet
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
MP501.pdf PDF
Interim MCMH French Creek_Drawing Set_Compiled.pdf PDF
Amendment 0001 Continuation Sheet.pdf PDF
N4008521R2524P00001.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
1430035dwg10of20_Architectural.pdf PDF
1430035dwg06of20_Civil.pdf PDF
1430035dwg15of20_FireSup.pdf PDF
1430035dwg20of20_Comm.pdf PDF
1430035dwg19of20_Electrical.pdf PDF
ATTACHMENT E PRICE PROPOSAL FORM.docx DOCX document
ATTACHMENT D SMALL BUSINESS SUBCONTRACTING PLAN.docx DOCX document
1430035spc01of03.pdf PDF
1430035dwg02of20_LifeSafety.pdf PDF
RFP N4008521R2524.pdf PDF
1430035dwg16of20_FireAlarm.pdf PDF
1430035dwg07of20_Landscape.pdf PDF
1430035dwg09of20_Architectural.pdf PDF
1430035dwg12of20_Architectural.pdf PDF
Attachment A - PPI Inquiry Log.xls XLS spreadsheet
1430035dwg14of20_Equipment.pdf PDF
1430035spc02of03.pdf PDF
1430035dwg13of20_Interiors.pdf PDF
ATTACHMENT C Past Performance Questionnaire.pdf PDF
1430035dwg11of20_Architectural.pdf PDF
1430035dwg05of20_Borings.pdf PDF
1430035dwg03of20_Phasing.pdf PDF
1430035spc03of03.pdf PDF
1430035dwg08of20_Structural.pdf PDF
1430035dwg17of20_Plumbing.pdf PDF
1430035dwg01of20_General.pdf PDF
1430035dwg18of20_Mechanical.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HAZARDOUS MATERIALS ABATEMENT GENERAL NOTES

A HAZARDOUS MATERIALS SURVEY WAS COMPLETED AT FACILITY 308, P4040 MEDICAL CLINIC IN ACCORDANCE WITH THE GENERAL REQUIREMENTS OF UFC 3-800-10N, GENERAL ENVIRONMENTAL AND UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (USEPA). THE SURVEY IS INTENDED TO IDENTIFY THE EXISTENCE OF DANGEROUS BUILDING MATERIALS THAT COULD BE HARMFUL TO THE PUBLIC HEALTH AND THE ENVIRONMENT BEFORE RENOVATION WORK BEGINS. THE SITE ASSESSMENT WAS PERFORMED BY OBSERVING, TOUCHING, AND SAMPLING AVAILABLE SUSPECT MATERIALS TO BE KNOWN TO CONTAIN HAZARDOUS MATERIALS AS PART OF THEIR MAKE-UP. THE HAZARDOUS MATERIAL SURVEY INCLUDED ASBESTOS CONTAINING MATERIAL, LEAD BASED PAINT, AND OTHER HAZARDOUS MATERIAL SUCH AS PCB'S, MERCURY, AND UNIVERSAL WASTE.

ASBESTOS-CONTAINING BUILDING MATERIALS (ACBM) ABATEMENT NOTES

1. ACBM HAS BEEN IDENTIFIED IN AND ON THE FACILITY PLANNED FOR RENOVATION. THE CONTRACTOR MUST ABIDE TO THE

REQUIREMENTS OF THE CONTRACT DOCUMENTS AND COMPLY WITH TITLE 40 CODE OF THE FEDERAL (CFR) REGULATIONS, PART 61;

NORTH CAROLINA ASBESTOS HAZARD MANAGEMENT PROGRAM/HEALTH HAZARDS CONTROL UNIT REGULATIONS 10A NCAC 41C.0601; TITLE 29 CFR PART 1926 ENFORCED BY OSHA, AND USEPA ASBESTOS HAZARD EMERGENCY RESPONSE ACT (AHERA) 40

CFR PART 763.

2. NON- BUILDING AND/OR SYSTEM MODIFICATIONS WHICH MAY HAVE OCCURRED SINCE THE ASBESTOS SURVEY MAY HAVE ALTERED THE CONDITIONS OF THE REPORT. A COMPLETE COPY OF THE HAZARDOUS MATERIAL REPORT CAN BE OBTAINED FROM THE

CONTRACTING OFFICER.

3. CONTRACTOR MUST SUBMIT AN “ASBESTOS HAZARD ABATEMENT PLAN” 30 DAYS PRIOR TO THE PLANNED DISTURBANCE OF ACBM.

NO DISTURBANCE OF ACBM MUST OCCUR UNTIL THE PLAN IS APPROVED BY THE CONTRACTING OFFICER.

4. CONTRACTOR MUST SUBMIT A NOTIFICATION FORM FOR ASBESTOS RENOVATION, ENCAPSULATION, OR DEMOLITION 10 DAYS PRIOR TO DISTURBANCE OF ACBM. THE CONTRACTING OFFICER MUST BE COPIED ON ALL NOTIFICATION AND REPORTS TO THE APPLICABLE

REGULATORY AGENCIES.

5. ABATEMENT OF NON-FRIABLE ASBESTOS PRIOR TO OR AS PART OF RENOVATION MUST BE DETERMINED BY THE APPLICABLE LANDFILL BEING USED FOR DISPOSAL OF DEBRIS. NON-FRIABLE ASBESTOS MAY BE ACCEPTED AT LOCAL LANDFILLS IN ACCORDANCE WITH THE LANDFILL OPERATIONAL REQUIREMENTS. A RECEIPT OF DISPOSAL MUST BE COPIED TO THE CONTRACTING

OFFICER.

6. ANY ADDITIONAL ACBM ENCOUNTERED, NOT REPORTED IN THE HAZARDOUS MATERIAL SURVEY REPORT, MUST BE REPORTED TO THE CONTRACTING OFFICER IMMEDIATELY FOLLOWING DISCOVERY. NO ADDITIONAL ACBM ABATEMENT MUST BE PERFORMED

WITHOUT WRITTEN AUTHORITY FROM THE CONTRACTING OFFICER.

7. SOME AREAS HAD LIMITED ACCESS AND WERE NOT FULLY INVESTIGATED. AN ADDITIONAL ASSESSMENT PRIOR TO START DEMOLITION WORK BY A LICENSED ASBESTOS CONTRACTOR IS RECOMMENDED FOR THE PROPER REMOVAL AND DISPOSAL OF

HAZARDOUS MATERIALS.

LEAD BASED PAINT ABATEMENT NOTES

1. TOXIC METALS IN PAINT ARE PRESENT IN AND ON THE STRUCTURES SCHEDULED TO BE DEMOLISHED. THE CONTRACTOR MUST

SUBMIT A SITE-SPECIFIC HEALTH AND SAFETY PLAN TO THE CONTRACTING OFFICER PRIOR TO START DEMOLITION WORK. THE CONTRACTOR MUST ABIDE BY THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND ALL APPLICABLE LOCAL GOVERNMENTAL

LAWS AND REGULATIONS.

2. PAINTED SURFACES ON THE STRUCTURE OF THE BUILDINGS DO HAVE THE PRESENCE OF LEAD AND POTENTIALLY OTHER TOXIC METALS. THE CONTRACTOR MUST PROTECT ALL PERSONNEL FROM EXPOSURE (INHALATION, INGESTION, ETC.) TO TOXIC METALS IN

ACCORDANCE WITH APPLICABLE LOCAL GOVERNMENTAL LAWS AND REGULATIONS.

3. RECYCLING AND/OR LANDFILL DISPOSAL OF LEAD PAINTED STRUCTURES IS PERMITTED AND MUST BE IN ACCORDANCE WITH

APPLICABLE LOCAL GOVERNMENTAL LAWS AND REGULATIONS.

4. ALL PAINTED SURFACES IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS ARE CONFIRMED TO CONTAIN LEAD UNLESS OTHERWISE TESTED. THE CONTRACTOR MUST ABIDE THE EU-OSHA STANDARDS WHEN DISTURBING THE COATING. ALL CONTRACTOR PERSONNEL WHO UTILIZE RESPIRATORY PROTECTION MUST COMPLY WITH EU-OSHA STANDARD FOR RESPIRATORY

PROTECTION.

5. THE CONTRACTOR MUST USE BEST "STANDARD OF CARE" TO CONTROL MEASURES IN ACCORDANCE WITH THE SPECIFICATIONS TO

PREVENT THE RELEASE OF TOXIC METAL PAINT CHIPS TO THE ENVIRONMENT.

OTHER HAZARDOUS MATERIALS NOTES

1. CONTRACTOR MUST DRAIN, PURGE, AND/OR OTHERWISE REMOVE, COLLECT, AND DISPOSE OF CHEMICAL GASES, REFRIGERANTS, HYDRAULIC FLUIDS, EXPLOSIVE, ACIDS, FLAMMABLES, HEAVY METALS OR OTHER DANGEROUS MATERIALS OR ITEMS THAT MAY CONTAIN THOSE MATERIALS, INCLUDING BUT NOT LIMITED TO PRESSURE SWITCHES, THERMOSTAT, BALLAST TRANSFORMERS, LEAD FLASHING, FLUORESCENT LAMPS, HIGH DENSITY DISCHARGE LAMPS, BATTERIES IN EXIT SIGNS AND EMERGENCY LIGHTING, ETC.

BEFORE PROCEEDING WITH RENOVATION OPERATIONS. DISPOSAL MUST BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS

AND APPLICABLE LOCAL GOVERNMENTAL LAWS AND REGULATIONS.

HAZARDOUS MATERIALS FIELD SURVEY

A HAZARDOUS MATERIALS FIELD SURVEY WAS CONDUCTED FROM JANUARY 31, 2017 TO FEBRUARY 1, 2017. THE FOLLOWING TABLE SUMMARIZES THE HAZARDOUS MATERIAL CONSTITUENTS THAT WERE IDENTIFIED DURING THE SURVEY:

E N G I N E

E R

O

FESS IO NA L

NO. 51380

F L O R I D A

STATE OF

R P

P A U

L

M. GOLDSM

IT

HL

I CENSE

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

IO

N

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

D

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-A

_r

_m ec rlf ae .c om .rv t

/2

5/

:5 3:

P

M

1" = 1'-0"

H A

Z A

R D

O U

S A

B A

T E

M E

N T

G E

N E

R A

L N

O T

E S

HD001

TJH PG/MEC PG

12760430

11/18/20

DJD

mec Text Box

DSN

PROS LAB

x087

VEST

x124

PROS

x146

PROS

x145

GEN DTR

x144

GEN DTR

x143

SUB-WAIT

x141

ELEC

x069

MECHANICAL

x070

CERAMICS

x085

CASTING

x086

SUPPLY

x084

MALE STAFF

x080

FEMALE STAFF

x126

COMM

x128

PROS SUPV

x129

LCPO

x077

LPO

x078

ADMIN

x076

BRANCH DIR

x075

STOR

x074

SUPPLY ADMIN

x073

CONFERENCE

x072

CORR

x088

CORR

x110 CORR x125

SUB-WAIT

x123

COURTYARD

x150

GEN DTR

x130

GEN DTR

x131

XRAY

x105

X-RAY ADMIN

x104

ENDO SUPV

x103

ENDO

x111

HOUSEKEEPING

x118

ENDO

x112

ORAL HYGIENE

x113

ORAL HYGIENE

x114

SICK CALL

x121

ORAL DIAG

x120

ORAL DIAG

x119

FEMALE LCKR

x096

SURGERY SUPV

x097

TLT

x098

FEMALE LCKR

x099

PERIO

x100

ORAL DIAG

x106

CSR SOIL

x089

CSR CLEAN

x066

SURG SPRT

x090

SCRUB

x091

ORAL SURG

x092

PERIO SUPV

x093

MALE TLT

x094

PERIO

x101

ORAL DIAG

x107

OFFICE

x108FEMALE TLT x102 x062

PHARMACY

x068

LOUNGE

x067

AUDIO

x001

LOUNGE

x002

SECURE STOR

x003

OFFICE

x004

TREATMENT

x005

PHYSICIAN

POD

x006

SCREENING

x007

SCREENING

x009

MALE

LOCKER

x011

FEMALE

LOCKER

x008

MALE TLT

x010

FEMALE

TLT

x065

CORR

x012

CORR

x013

OFFICE

x014

TLT

x015

TLT

x016

OFFICE

x017

PROCESS

x018

SUPPORT

x020

CONTROL

x019

GENERATOR

x021

ELEC

x032

OFFICE

x031

JAN

x030

TLT

x029

TLT

x028

COPY /

STOR

x036

PROV /

EXAM

x037

PROV /

EXAM

x038

PROV /

EXAM

x025

PHA

x022

XRAY

x035

IMMUNIZATION

x034

OFFICE

x033

OFFICE x039

PROV /

EXAM

x040

EXAM

x041

EXAM

x048

SICK CALL /

CONTROL

x047

SCREENING

x055

ADMIN

x053

LPO

x045

EXAM

x044

EXAM

x046

SCREENING

x049

LAB

x054

RECORDS

x057

MALE TLT

x056

FEMALE TLT

x043

EXAM

x052

CONTROL

x050

VENIPUNCTURE

x051

SPECIMEN

x058

WAITING

x026

CONTROL

x024

DRESS

x023

DRESS

x027

CORR

x027

CORR x042

CORR

x148

OFFICE

x060

WAITING

x059

VEST

x147

LOBBY

x061

CORR

CONTROL / RECORDS

x117

ORAL DIAG SUPV

x115

GEN DTR

x122

TEAM DTR

x134

CORR

x140

GEN DTR

x135

TEAM DTR

x136

CONSULT

x137

GEN DTR

x138

GEN DTR

x139

CONSULT

x132

GEN DTR

x133

CORR

x142 x149

PSYCH TEST

CORR

x109

FEC

FEC

FEC

FEC

FEC

JAN

x081

WAITING

x109A

WAITING

x109B

PCM-4

LBP-1

LBP-2

LBP-3,

LBP-4

PMU-3

PMU-1, PMU-2

(ENTIRE FACILITY)

PMU-1, PMU-2

(ENTIRE FACILITY)

ACBM-1

(MEDICAL CLINIC)

A. REFER TO GI SHEETS FOR GENERAL NOTES, ABBREVIATIONS, AND

GENERAL SYMBOLS.

B. REFER TO SHEET HD001 FOR HAZARDOUS MATERIAL ABATEMENT

GENERAL NOTES.

C. PROVIDE HAZARDOUS MATERIAL ABATEMENT NOTIFICATION TO NORTH

CAROLINA ASBESTOS HAZARD MANAGEMENT PROGRAM/HEALTH

HAZARDS CONTROL UNIT AND THE CONTRACTING OFFICER AT LEAST 10

BUSINESS DAYS PRIOR TO THE COMMENCEMENT OF DEMOLITION WORK.

D. THIS SET OF DRAWINGS ONLY INDICATE THE LOCATION OF HAZARDOUS

MATERIALS, AND DO NOT PRESCRIBED MEANS AND METHODS FOR THE

REMOVAL OF HAZARDOUS MATERIALS.

E. DUE TO THE HIDDEN NATURE OF MANY BUILDING COMPONENTS, IT MAY BE

IMPOSSIBLE TO LOCATE ALL SUSPECTED HAZARDOUS MATERIALS, AN

ESTIMATE HAS BEEN PERFORMED BASED ON THE QUANTITIES AND / OR

CONDITIONS OF READILY VISIBLE SUBJECTS.

HAZMAT MATERIAL LEGEND

ACBM SURVEY

ACBM-1 BLACK MASTIC ASSOCIATED WITH FLOOR TILE, 5%

CHRYSOTILE, APPROXIMATELY 12,800 SQ FT

LEAD-BASED PAINT (LBP) SURVEY

LBP-1 RED FIRE LINE TEE FITTING, 5 SQ FT.

LBP-2 EYEWASH STATION YELLOW WATER PIPE, 10 LF

LBP-3 X-RAY ROOM PARTITION (LEAD SHIELDING), 56 SQ FT

LBP-4 X-RAY ROOM ENTRY DOOR (LEAD SHIELDING),

42 SQ FT

PCB / MERCURY / UNIVERSAL WASTE SURVEY

PMU-1 FLUORESCENT LAMPS / PCB BALLASTS

(ENTIRE FACILITY)

PMU-2 UNIVERSAL WASTE - EXIT SIGN WITH FLUORESCENT

LAMPS AND BACK UP BATTERIES REGULATED UNDER

40 CFR PART 273 REQUIRE TO BE RECYCLED.

(ENTIRE FACILITY)

PMU-3 THERMOMETERS IN MECHANICAL ROOMS MAY

CONTAIN MERCURY.

PMU-4 EXTERIOR PROPANE TANK

BLACK MASTIC ASSOCIATED WITH

FLOOR TILE, 5% CHRYSOTILE,

APPROXIMATELY 12,800 SQ FT

ACBM SURVEY LEAD-BASED PAINT (LBP) SURVEY

RED FIRE LINE TEE FITTING, 5 SQ FT. EYEWASH STATION YELLOW WATER PIPE,

10 LF

X-RAY ROOM PARTITION (LEAD

SHIELDING), 56 SQ FT

X-RAY ROOM ENTRY DOOR (LEAD

SHIELDING), 42 SQ FT

PCB / MERCURY / UNIVERSAL WASTE SURVEY

FLUORESCENT LAMPS / PCB BALLASTS. UNIVERSAL WASTE - EXIT SIGN WITH

FLUORESCENT LAMPS AND BACK UP

BATTERIES REGULATED UNDER 40 CFR

PART 273 REQUIRE TO BE RECYCLED.

THERMOMETERS IN MECHANICAL ROOMS

MAY CONTAIN MERCURY.

EXTERIOR PROPANE TANK

E N G I N E

E R

O

FESS IO NA L

NO. 51380

F L O R I D A

STATE OF

R P

P A U

L

M. GOLDSM

IT

HL

I CENSE

SHEET NOTES:

NOTES:

KEYPLAN

KEYPLAN

KEYPLAN

0 10'

1/16" = 1'-0" GRAPHIC SCALE

20' 40' 60'

NPROJECT

NORTH

KEYPLAN

KEYPLAN

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

IO

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

D

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-A

_r

_m ec rlf ae .c om .rv t

/2

5/

:5 3:

P

M

As indicated

H A

Z A

R D

O U

S M

A T

E R

IA

LS

F

LO

O R

P

LA

N

HD101

TJH PG/MEC PG

12760431

11/18/20

SCALE: 1/16" = 1'-0" AD200 B4

HAZARDOUS MATERIALS PLAN, COMPOSITE

DJD

mec Text Box

DSN

HD001 - HAZARDOUS ABATEMENT GENERAL NOTES
HD101 - HAZARDOUS MATERIALS FLOOR PLAN
2021-01-08T08:36:50-0500
Orlando, FL
Paul Goldsmith
I am signing to certify the authenticity of this document.
2021-01-08T08:38:49-0500
Orlando, FL
Paul Goldsmith
I am signing to certify the authenticity of this document.
2021-01-16T16:19:00-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-01-16T16:19:33-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-01-16T16:19:51-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-01-16T16:20:05-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .