About this file

This solicitation is for a design-bid-build construction project for the P4040 French Creek Ambulatory Care Clinic located at Camp Lejeune, North Carolina. The Navy is seeking proposals for the construction of an addition and alterations to the existing clinic, including renovations and upgrades to the dental area. Proposals are due by January 25, 2022. The anticipated award date is March 2022, with construction to be completed by February 2024. The total budget for the project is $15-20 million. Small businesses are encouraged to compete for the contract.

View the file

Other files

File Type Posted
N4008521R2524P00006.pdf PDF
AMEND 06 ATTACHMENT E PRICE PROPOSAL FORM.docx DOCX document
AMD 5 ATTACH 2 Site Visit 6.17.21.pdf PDF
AMD 5 ATTACH 1 P4040 PPIs VER2.xlsx XLSX spreadsheet
N4008521R2524P0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003 Attachment (1) NC20210038 WGDET.pdf PDF
Amendment 0003 Attachment (2) PPIs.xlsx XLSX spreadsheet
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
MP501.pdf PDF
Interim MCMH French Creek_Drawing Set_Compiled.pdf PDF
Amendment 0001 Continuation Sheet.pdf PDF
N4008521R2524P00001.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
1430035dwg10of20_Architectural.pdf PDF
1430035dwg06of20_Civil.pdf PDF
1430035dwg15of20_FireSup.pdf PDF
1430035dwg19of20_Electrical.pdf PDF
ATTACHMENT E PRICE PROPOSAL FORM.docx DOCX document
ATTACHMENT D SMALL BUSINESS SUBCONTRACTING PLAN.docx DOCX document
1430035spc01of03.pdf PDF
1430035dwg02of20_LifeSafety.pdf PDF
RFP N4008521R2524.pdf PDF
1430035dwg16of20_FireAlarm.pdf PDF
1430035dwg07of20_Landscape.pdf PDF
1430035dwg09of20_Architectural.pdf PDF
1430035dwg12of20_Architectural.pdf PDF
1430035dwg04of20_Hazmat.pdf PDF
Attachment A - PPI Inquiry Log.xls XLS spreadsheet
1430035dwg14of20_Equipment.pdf PDF
1430035spc02of03.pdf PDF
1430035dwg13of20_Interiors.pdf PDF
ATTACHMENT C Past Performance Questionnaire.pdf PDF
1430035dwg11of20_Architectural.pdf PDF
1430035dwg05of20_Borings.pdf PDF
1430035dwg03of20_Phasing.pdf PDF
1430035spc03of03.pdf PDF
1430035dwg08of20_Structural.pdf PDF
1430035dwg17of20_Plumbing.pdf PDF
1430035dwg01of20_General.pdf PDF
1430035dwg18of20_Mechanical.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

B.6

B.8

C

D

E

F

1 1.82 2.2 2.6 3 3.3 3.73.8 4 4.8

X12X12X11X11X10X10X9.8X9.8X9.5X9.5X8X8X7.2X7.2X7X7X6.6X6.6

X5X5

X4.5X4.5

X4X4X3X3X2.4X2.4X2X2 X3.2X3.2 X3.4X3.4X3.5X3.5 X3.8X3.8 X4.3X4.3 X4.8X4.8 X6.2X6.2X6.3X6.3X6.5X6.5 X6.9X6.9 X7.3X7.3

X7.6X7.6X7.7X7.7 X8.3X8.3X8.4X8.4 X8.6X8.6X8.8X8.8 X9.2X9.2X9.4X9.4 X9.6X9.6

XC.3XC.3

XEXE

XFXF

XGXG

XH.5XH.5

XJXJ

XK.4XK.4

XLXL

XL.6XL.6

XMXM XM.1XM.1XM.05XM.05

XNXN

XPXPXRXR

XHXH

XF.9XF.9

XKXK

XC.6XC.6

XB.4XB.4

XBXB

XAXA

XCXC XC.1XC.1

x087

PROS LAB

x141

SUB-WAIT

x124

VEST

x146

PROS

x145

PROS

x144

GEN DTR

x143

GEN DTR

x089

CSR SOIL

x090

SURG SPRT

x091

SCRUB

x092

ORAL SURG

x073

SUPPLY ADMIN

x074

STOR

x075

BRANCH DIR

x069

ELEC

x070

MECHANICAL

x134

TEAM DTR

x140

CORR

x133

GEN DTR

x132

CONSULT

x138

GEN DTR

x137

CONSULT

x136

TEAM DTR

x135

GEN DTR

x109

CORR

x094

MALE TLT

x102

FEMALE TLT

x108

OFFICE

x101

PERIO

x093

PERIO SUPV

x100

PERIO

x099

FEMALE LCKR

x098

TLT

x104

X-RAY ADMIN

x103

ENDO SUPV

x096

FEMALE LCKR

x097

SURGERY SUPV

x105

XRAY

x095

CORR

x077

LCPO

x078

LPO

x080

MALE STAFF

x076

ADMIN

x084

SUPPLY

x085

CERAMICS

x086

CASTING

x107

ORAL DIAG

x106

ORAL DIAG

x110

CORR

x113

ORAL HYGIENE

x112

ENDO

x118

HOUSEKEEPING

x119

ORAL DIAG

x120

ORAL DIAG

x121

SICK CALL

x122

GEN DTR

x117

CONTROL /

RECORDS

x115

ORAL DIAG SUPV

x114

ORAL HYGIENE

x111

ENDO

x125

CORR

x126

FEMALE STAFF

x128

COMM

x129

PROS SUPV

x150

COURTYARD

x088

CORR

x130

GEN DTR

x131

GEN DTR

x142

CORR

x123

SUB-WAIT

x139

GEN DTR

1G22

LOUNGE

1G20

JAN

1G18

CONF

1E23

CHIEF (SMO)

1E21

RN MNGR

1E19

LCPO / LPO

1G17

TLT

1G15

COMM

1E26

TREAT

1E28

SOILED

1E14

TLT

1H02

GAS STOR

1E27

TREAT

1G09

EQUIPMENT

1E29

CLEAN

1D17

TLT

1E11

EXAM

1E09

EXAM

1E12

EXAM

1E17

EKG

1E13

VISION SCREEN

1E18

MCMH TEAM LEAD

1F04

EQUIPMENT

1E35

EXAM

1E39

EXAM

1E37

EXAM

1E41

EXAM

1E07

EXAM / CONSULT

1E05

EXAM / CONSULT

1E03

EXAM / CONSULT

1E44

EXAM

1E43

TLT

1D02

WAIT / OBS

1D05

IMMUNI

1D13

EXAM

1C12

RN (BH)

1D25

EXAM

1A08

TLT MALE

1C06

LAB

1C02

DRAWING

1C04

SPECIMEN TLT

1C10

PROV (BH)

1C05

DRESS

1C08

JAN

1C03

RAD

1A01

VEST

1A04

CLASS

1A05

WAIT

1DC2A

MEASURES

1D08

TEAM

COLLABORATION

1E24

OBS / HYD

1G03

DENTAL LOUNGE

1B01

MEDICAL RECORDS

1C01

RECEPTION

1A03

WAIT

1A02

LOBBY

1C07

PHARMACY

x066

CSR CLEAN

x072

CONFERENCE

1EC5

CORR

1EC4

CORR

1CC1

CORR

1AC2

CORR

1GC1

CORR

1G12

M LOCKERS

1G14

F LOCKERS

1G14B

SHWR

1G12B

SHWR

1G12A

TLT

1G14A

TLT

1G14C

SHWR

1G12C

SHWR

1GC2

CORR

1G01

ELEC

1A06

TLT FEMALE

1A10

WAIT

1A09

WAIT

1E32

LACTATION

1GC4A

ICE

1E16

EXAM

1F02

REHAB

1E01

RECEPTION

1EC2A

MEASURES

1E06

TEAM

COLLABORATION

1G08

LOGISTICS

1D15

TLT

1D19

EXAM

1D18

MCMH TEAM LEAD

1G07

TRASH / RECYC

1G04

RMW

1G02

JAN

1D11

EXAM

1D07

EXAM

1D03

EXAM / CONSULT

1D29

TLT

1D27A

TLT, ISO

1DC5

CORR

1DC1

CORR

1DC2

CORR

1DC3

CORR

1DC4

CORR

1EC6

CORR

1CC6

CORR

1EC1

CORR

1EC3

CORR

1GC3

CORR

1GC4

CORR

1EC2

CORR

1D01

RECEPTION

1D24

EXAM

1D23

EXAM

1D27

EXAM, ISO

1D09

EXAM

x081

JAN

x109A

WAITING

x109B

WAITING

1F01

PHYSICAL THERAPY

1EC7

CORR

1AC1

CORR

1A02A

KIOSK

1AC3

CORR 1A05A

KIOSK

1AC4

CORR

1AC1C

DISPENSE

1AC1A

DISPENSE

1AC1B

MEDS RETURN

1D12

EXAM

1D21

AUDIOBOOTH

1G19

ELEC

1G10

MAIN COMM

1H01

MAIN ELEC

1G06

MECH

VOICE/DATA

ZONE A VOICE/DATA

ZONE B

VOICE/DATA

EXISTING ZONE

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

SHEET NOTES:

NOTES:

0 10'

1/16" = 1'-0" GRAPHIC SCALE

20' 40' 60'

NPROJECT

NORTH

KEYPLAN

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

IO

N

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

D

M

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 1:

P

M

1/16" = 1'-0"

C O

M M

U N

IC

A

T

IO

N S

, C A

B

LE

T R

A Y

ET101

NGZ SSS DRS

12760774

11/18/20

SCALE: 1/16" = 1'-0" A4

COMMUNICATIONS, CABLE TRAY

A. ALL CABLE TRAY IS 18" WIDE BY 4" DEEP BASKET TYPE UNLESS

OTHERWISE NOTED.

B. LOCATE CABLE TRAY ABOVE FINISHED CEILINGS IN CORRIDORS AND

ROOMS INDICATED ON THIS DRAWING. ACTUAL LOCATION AND ROUTING

WITHIN THE CORRIDORS AND ROOMS SHALL BE COORDINATED WITH

OTHER TRADES AND SYSTEMS. PROVIDE OFFSETS AND BENDS AS

REQUIRED TO AVOID OBSTACLES AND COORDINATE WITH OTHER

TRADES AND SYSTEMS. MAINTAIN 12" CLEAR ZONE ABOVE AND ON ONE

SIDE OF ALL CABLE TRAYS. PIPING, DUCTWORK, AND CONDUIT MAY

CROSS THE CLEAR ZONE PERPENDICULAR TO, OR AT A DIAGONAL TO

THE CABLE TRAY PROVIDED THE CROSSING WIDTH DOES NOT EXCEED

48". CABLE TRAY SHALL BE INSTALLED SO THAT THE BOTTOM OF THE

TRAY IS NO HIGHER THAN 18" ABOVE THE CEILING AND NO CLOSER

THAN 4" TO THE CEILING.

C. PROVIDE MINIMUM 5" SEPARATION BETWEEN FLUORESCENT LIGHTING

FIXTURES AND CABLE TRAY.

D. ALL HORIZONTAL VOICE AND DATA CABLES SHALL BE TERMINATED IN

THE COMMUNICATIONS ROOM LOCATED IN THE SAME

TELECOMMUNICATIONS ZONE AS THE VOICE AND DATA OUTLET.

1 PROVIDE UL LISTED FIRE RATED PATHWAY ASSEMBLY. PROVIDE #6

AWG INSULATED COPPER CONDUCTOR AND BOND TO CABLE TRAY

IN RENOVATED AREA AND EXISTING CABLE TRAY IN DENTAL AREA.

2 VOICE/DATA PATCH PANELS IN THIS ROOM SHALL SUPPORT ALL

VOICE/DATA OUTLETS LOCATED IN ZONE A.

3 VOICE/DATA PATCH PANELS IN THIS ROOM SHALL SUPPORT ALL

VOICE/DATA OUTLETS LOCATED IN ZONE B.

4 VOICE/DATA PATCH PANELS IN THIS ROOM SUPPORT ALL EXISTING

VOICE/DATA OUTLETS LOCATED IN THE EXISTING ZONE.

5 6" WIDE CABLE TRAY.

JAS

mec Text Box

DSN

V

A V

S S S S S

S

S

S

S

S

S

S

S

S

S S S

S

S

S

S

S

S

S

S

S S S

S S

S S

T P

T P

TP

V

S S

NC

NC

NC

ZC

ZC

ZC

ZC

N A

ZC

ZC

S

S

S

S

AV

A V

A V

T V

V

S S S

NP CB

NP CB

NC

NC

ZC

J

CB NP

NC

NC

NC

NC

CB

NC

N P

N P

N P

NC

N P

NC

V

TV J

V

1G22

LOUNGE

1G20

JAN

1G18

CONF

1E23

CHIEF

(SMO)

1E21

RN MNGR

1E19

LCPO /

LPO

1G17

TLT

1G15

COMM

1E26

TREAT

1E28

SOILED

1E14

TLT

1E27

TREAT

1E29

CLEAN

1E11

EXAM

1E09

EXAM

1E12

EXAM

1E17

EKG

1E13

VISION

SCREEN

1E18

MCMH

TEAM

LEAD

1F04

EQUIPMENT

1E35

EXAM

1E39

EXAM

1E37

EXAM

1E41

EXAM

1F01

PHYSICAL

THERAPY

1E07

EXAM /

CONSULT

1E05

EXAM /

CONSULT

1E03

EXAM /

CONSULT

1E44

EXAM

1E43

TLT

1D02

WAIT / OBS

1E24

OBS / HYD

1EC5

CORR

1EC4

CORR

1G12 M

LOCKERS

1G14 F

LOCKERS

1G14B

SHWR

1G12B

SHWR

1G12A

TLT

1G14A

TLT1G14C

SHWR

1G12C

SHWR

1A10

WAIT

1A09

WAIT

1E32

LACTATION

1GC4A

ICE

1E16

EXAM

1F02

REHAB

1E01

RECEPTION

1EC2A

MEASURES

1E06

TEAM

COLLABORATION

1EC6

CORR

1EC1

CORR

1EC3

CORR

1GC3

CORR

1GC4

CORR

1EC2

CORR

B

B.6

B.8

C

D

E

F

1 1.8 2 2.2 2.6 3 3.3 3.7 3.8 4

XC.6XC.6

XB.4XB.4

ET401

A2

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

ET401

A3

TVA

TVA

D,F

D,F

Z-1GC4 D-1G17

Z-1EC5

D-1E14

Z-1EC4 Z-1EC4

Z-1EC1

Z-1EC3

NA-1E01

D-1E43

Z1 Z1 Z1

Z1 Z1

Z1Z1Z1Z1Z1

Z1

Z1

Z1

Z1

Z1

Z1

Z1

Z1Z1

Z1

Z1 Z1

Z1 Z1

Z1

Z1

Z1 Z1

Z1 Z1

N10

Z1

Z1

Z1

Z1Z1

Z1

Z1

2D,V

MM

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

TVA

D,F

TVA

D,F

1G19

ELEC

1E33

DERM

STORAGE

1AC4

CORR

NMCI

NMCI

NMCI

NMCI

Z1

Z2 Z2 Z2

N M

C I

N M

C I

Z1

2 2

D-1E26 D-1E27

Z-1EC1

+48"

D-1F01

D-1F01

D-1F01D

D-1F01C

D-1F01B

D-1F01A

D-1E17

AVA

Z1

TFF

MFB

MFB

MFB

MFB

MFB

MFB

Z1

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

NPROJECT

NORTH

KEYPLAN

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 1:

P

M

1/8" = 1'-0"

C O

M M

U N

IC

A

T

IO

N P

LA

N

, S E

C T

O R

ET101-1

NGZ BTB DRS

12760775

11/18/20

SCALE: 1/8" = 1'-0" A4

COMMUNICATION PLAN, SECTOR 1

1 REFERENCE POWER PLAN EP101-1 FOR FLOOR MOUNTED

COMBINATION POWER/DATA BOX LOCATIONS.

2 LOCAL VOLUME CONTROLS FOR SPEAKERS IN THIS ROOM.

3 4 11/16" SQUARE X 2 1/8" DEEP BOX WITH SINGLE GANG PLASTER

RING AND BLANK COVER PLATE FOR QUEUE-MANAGEMENT KIOSK.

MOUNT 18" AFF TO CENTER. PROVIDE 1" EMPTY CONDUIT WITH

PULL STRING TO NEAREST CABLE TRAY. SEE A2/ET501 FOR

CONDUIT TO CABLE TRAY TERMINATION DETAIL.

4 4 11/16" SQUARE x 2 1/8" DEEP BOX WITH SINGLE GANG PLASTER

RING AND BLANK COVER PLATE FOR QUE-MANAGEMENT MONITOR.

PROVIDE 1" EMPTY CONDUIT WITH PULL STRING TO NEAREST

CABLE TRAY. SEE A2/ET501 FOR CONDUIT TO CABLE TRAY

TERMINATION DETAIL. COORDINATE EXACT MOUNTING HEIGHT

SUCH THAT IT IS CONCEALED YET ACCESSIBLE BEHIND MONITOR.

MOUNT ADJACENT TO TV OUTLET.

5 MOUNT ADJACENT TO QUE-MANAGEMENT SYSTEM OUTLET BOX.

6 LOCATE ADJACENT TO POWER FURNITURE FEED FLOOR BOX.

COORDINATE LOCATION WITH CONTRACTING OFFICER.

JAS

mec

T V

S S S S S S S

S

S

S S S S

S

S

S

S

S

TP

TP

SS

V

NC

NC

NC

ZC

ZC

ZC

TP

AV AV AV

S A

SA

NC

SA

S A

NC

V

S

NP

N P

N P

C B

C B

C B x089

CSR SOIL

x090

SURG

SPRT

x091

SCRUB

x073

SUPPLY

ADMIN

x074

STOR

x069

ELEC

x070

MECHANICAL

1H02

GAS STOR

1G09

EQUIPMENT

1D17

TLT

1C12

RN (BH)

1C06

LAB

1C02

DRAWING

1C04

SPECIMEN

TLT

1C10

PROV (BH)

1A04

CLASS

1G03

DENTAL

LOUNGE x066

CSR

CLEAN

x072

CONFERENCE

1AC2

CORR

1GC1

CORR

1GC2

CORR

1G01

ELEC

1G08

LOGISTICS

1D15

TLT

1D19

EXAM

1D18

MCMH

TEAM

LEAD

1D21

AUDIOBOOTH

1G07

TRASH /

RECYC

1G04

RMW

1G02

JAN

1DC5

CORR

1CC6

CORR

1D23

EXAM

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

A

B

B.6

B.8

C

4 4.8 X7.2X7.2X7X7X6.6X6.6X6X6X5X5X4.5X4.5X4X4X3X3

ET401

B2

1D21

AUDIOBOOTH

MATCH LINE

SEE A4/ET101-3

MATCH LINE

SEE A4/ET101-3

1DC3

CORR

ET401

B3

D-1D17

D-1D15

Z-1CC6

Z-1DC5

Z-1DC3

D-1C04

Z2Z2

Z2

Z2

Z2 Z2

Z2 Z2 Z2 Z2

Z2 Z2

Z2Z2

Z2

Z2

Z2

Z2

Z2

Z2

LF

LF LF

WAP WAP

WAP

WAP

WAP

1G10

MAIN

COMM

1H01

MAIN ELEC

MM

TVA TVA

D,F D,F

1G06

MECH

2D,V

OC

R

D-1C12

R

D-1C10

NMCI

Z2

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

Z4

Z2

+48"

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

KEYPLAN

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

NPROJECT

NORTH

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 1:

P

M

1/8" = 1'-0"

C O

M M

U N

IC

A

T

IO

N P

LA

N

, S E

C T

O R

ET101-2

NGZ BTB DRS

12760776

11/18/20

SCALE: 1/8" = 1'-0" A4

COMMUNICATION PLAN, SECTOR 2

1 REFERENCE POWER PLAN EP101-2 FOR FLOOR MOUNTED

COMBINATION POWER/DATA BOX LOCATIONS.

2 LOCAL VOLUME CONTROLS FOR SPEAKERS IN THIS ROOM.

3 1 1/4" CONDUIT TO NEAREST CABLE TRAY FROM MODULAR

FURNITURE VERTICAL WIRE CHASE. SEE A3/ET504 FOR DETAIL.

JAS

mec

S

S

S S

SS

S

S

S

S

S

S

S

S

S

S

S S

S S

S S

TP

TP TP

T P

T P

T P

T P

NC

ZCZC

N A

NA

ZC

D P

V

S

S

S

S

S

S

S

S

S

NW NW

ZC

TP

NC

NC

S SS S S

S

S

NC

NC

J

J

P C

NP CB

NC

V

T V

J

TV

J x092

ORAL

SURG

x094

MALE TLT

x093

PERIO

SUPV

1D05

IMMUNI

1D13

EXAM 1D25

EXAM

1D12

EXAM

1A08

TLT MALE

1C05

DRESS

1C08

JAN

1C03

RAD

1A01

VEST

1A05

WAIT

1DC2A

MEASURES

1D08

TEAM

COLLABORATION

1B01

MEDICAL

RECORDS

1C01

RECEPTION

1A03

WAIT

1A02

LOBBY

1C07

PHARMACY

1CC1

CORR

1A06

TLT

FEMALE

1D11

EXAM

1D07

EXAM

1D03

EXAM /

CONSULT

1D29

TLT

1D27A

TLT, ISO

1DC1

CORR

1DC2

CORR

1DC3

CORR

1D01

RECEPTION

1D24

EXAM

1D27

EXAM, ISO

1D09

EXAM

MATCH LINE

SEE A4/ET101-2

D

E

F

4.8 X7.2X7.2X6.6X6.6X4.5X4.5

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

MATCH LINE

SEE A4/ET101-2

NA-1D01

Z-1DC3 Z-1DC1

D-1D29

NA-1C01

Z-1CC1

Z2 Z2

Z2

Z2

Z2 Z2

Z2

Z2 Z2

Z2 Z2

Z2 Z2

Z2

Z2

Z2

Z2

Z2

Z2

Z2

Z2

Z2

Z2

Z3

Z3 Z3

Z3

Z3

Z3

Z3

Z3

Z3

Z3

PF

WAP

WAP

WAP

WAP

WAP

WAP

WAP

Z-1AC3

D-1A08 D-1A061AC3

CORR

D-1D27A

D-1D27

Z2Z2 Z2 Z2 Z2

Z2

Z2

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

PF

PF

PF

PFPF

N M

C I

NMCI

NMCI

D-1C05

PF

PF

PF

PF

PF

PF

PF

PF

PF

PF

PF

PF

PF PF

PF

PF

+24"+24"

+48"

+48"

D-1D05

Z2

TFF

MFB

MFB

MFB

MFB

MFB

MFB

PP PP PP PP

D-1C02

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

KEYPLAN

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

NPROJECT

NORTH

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

1/8" = 1'-0"

C O

M M

U N

IC

A

T

IO

N P

LA

N

, S E

C T

O R

ET101-3

NGZ BTB DRS

12760777

11/18/20

SCALE: 1/8" = 1'-0" A4

COMMUNICATION PLAN, SECTOR 3

1 LOCATE ADJACENT TO POWER FURNITURE FEED FLOOR BOX.

COORDINATE LOCATION WITH CONTRACTING OFFICER.

2 1" CONDUIT TO CABLE TRAY. SEE A2/ET501 FOR TERMINATION DETAIL.

COORDINATE INSTALLATION OF MODULAR FURNITURE JACKS WITH

CONTRACTING OFFICER.

3 1 1/4" CONDUIT TO CABLE TRAY. SEE A2/ET501 FOR TERMINATION

DETAIL. COORDINATE INSTALLATION OF MODULAR FURNITURE JACKS

WITH CONTRACTING OFFICER.

4 1 1/2" CONDUIT TO CABLE TRAY. SEE A2/ET501 FOR TERMINATION

DETAIL. COORDINATE INSTALLATION OF MODULAR FURNITURE JACKS

WITH CONTRACTING OFFICER.

5 2 1/2" CONDUIT TO CABLE TRAY. SEE A2/ET501 FOR TERMINATION

DETAIL. COORDINATE INSTALLATION OF MODULAR FURNITURE JACKS

WITH CONTRACTING OFFICER.

6 4 11/16" SQUARE X 2 1/8" DEEP BOX WITH SINGLE GANG PLASTER RING

AND BLANK COVER PLATE FOR QUEUE-MANAGEMENT KIOSK. MOUNT 18"

AFF TO CENTER. PROVIDE 1" EMPTY CONDUIT WITH PULL STRING TO

NEAREST CABLE TRAY. SEE A2/ET501 FOR CONDUIT TO CABLE TRAY

TERMINATION DETAIL.

7 4 11/16" SQUARE x 2 1/8" DEEP BOX WITH SINGLE GANG PLASTER RING

AND BLANK COVER PLATE FOR QUE-MANAGEMENT MONITOR. PROVIDE

1" EMPTY CONDUIT WITH PULL STRING TO NEAREST CABLE TRAY. SEE

A2/ET501 FOR CONDUIT TO CABLE TRAY TERMINATION DETAIL.

COORDINATE EXACT MOUNTING HEIGHT SUCH THAT IT IS CONCEALED

YET ACCESSIBLE BEHIND MONITOR. MOUNT ADJACENT TO TV OUTLET.

8 1 1/4" CONDUIT TO CABLE TRAY. SEE A2/ET501 FOR TERMINATION

DETAIL. COORDINATE INSTALLATION OF MODULAR FURNITURE JACKS

WITH CONTRACTING OFFICER.

9 DEVICES FLUSH MOUNTED ON COMBINATION UTILITY POLE.

10 LOCAL VOLUME CONTROLS FOR SPEAKERS IN THIS ROOM.

11 MOUNT ADJACENT TO QUE-MANAGEMENT SYSTEM OUTLET BOX.

12 1 1/2" CONDUIT FROM TOP OF UTILITY POLE TO CABLE TRAY.

JAS

mec

S S S S S S S

S

S

S S S

S

S

S

S

S

S

S

S

S

S

S

S

SSS

S S

S

S

S

S x087

PROS LAB

x141

SUB-WAIT

x124

VEST

x146

PROS

x145

PROS

x144

GEN DTR

x143

GEN DTR

x089

CSR SOIL

x090

SURG

SPRT

x091

SCRUB

x092

ORAL

SURG

x073

SUPPLY

ADMIN

x074

STOR

x075

BRANCH

DIR

x134

TEAM DTR

x140

CORR

x133

GEN DTR

x132

CONSULT

x138

GEN DTR

x137

CONSULT

x136

TEAM DTR

x135

GEN DTR

x109

CORR

x094

MALE TLT

x102

FEMALE

TLT

x108

OFFICE

x101

PERIO

x093

PERIO

SUPV

x100

PERIO

x099

FEMALE

LCKR

x098

TLT

x104

X-RAY

ADMIN

x103

ENDO

SUPV

x096

FEMALE

LCKR

x097

SURGERY

SUPV

x105

XRAY

x095

CORR

x077

LCPO

x078

LPO

x080

MALE

STAFF

x081

JAN

x076 ADMIN x084

SUPPLY

x085

CERAMICS

x086

CASTING

x107

ORAL DIAG

x106

ORAL DIAG

x110

CORR

x113

ORAL

HYGIENE

x112

ENDO

x118

HOUSEKEEPING

x119

ORAL DIAG

x120

ORAL DIAG

x121

SICK CALL

x122

GEN DTR

x117

CONTROL /

RECORDS

x115

ORAL DIAG

SUPV

x114

ORAL

HYGIENE

x111

ENDO

x125

CORR

x126

FEMALE

STAFF

x128

COMM

x129

PROS

SUPV

x150

COURTYARD

x088

CORR

x130

GEN DTR

x131

GEN DTR

x142

CORR

x123

SUB-WAIT

x139

GEN DTR

B

B.6

B.8

C

D

E

X12X12X11X11X10X10X9.8X9.8X9.5X9.5X9X9X8X8X7.2X7.2X7X7

X6.9X6.9 X7.3X7.3 X7.6X7.6X7.7X7.7 X8.3X8.3X8.4X8.4 X8.6X8.6 X8.8X8.8 X9.2X9.2 X9.4X9.4 X9.6X9.6

XC.3XC.3

XEXE

XFXF

XGXG

XH.5XH.5

XJXJ

XK.4XK.4

XLXL

XL.6XL.6

XMXM

XM.1XM.1

XM.05XM.05

XNXN

XPXP

XRXR

XHXH

XF.9XF.9

XKXK

XC.6XC.6

XCXC

XC.1XC.1

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

M A

T C

H L

IN

E

S E

E A

4/ E

T

1-

Z4 Z4 Z4

Z4 Z4 Z4 Z4 Z4 Z4 Z4

Z4

Z4

Z4

Z4

Z4

Z4Z4Z4

Z4

Z4Z4

Z4

Z4

Z4

Z4

Z4

Z4

Z4

Z4 Z4

Z4

Z4

Z4

Z4

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

SHEET NOTES:

NOTES:

KEYPLAN

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

NPROJECT

NORTH

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

1/8" = 1'-0"

C O

M M

U N

IC

A

T

IO

N P

LA

N

, S E

C T

O R

ET101-4

NGZ SSS DRS

12760778

11/18/20

SCALE: 1/8" = 1'-0" A4

COMMUNICATION PLAN, SECTOR 4

A. REMOVAL OF EXISTING SPEAKERS AND ASSOCIATED CONDUIT AND WIRING

AND INSTALLATION OF REPLACEMENT SPEAKERS AND ASSOCIATED CONDUIT

AND WIRING SHALL OCCUR DURING THE 30-DAY PERIOD SCHEDULED FOR

THE DENTAL PORTION OF THE CLINIC TO BE VACATED. COORDINATE

SCHEDULE WITH CONTRACTING OFFICER.

JAS

mec

B

NMCI

ER3

ER2

ACAS-1 VSS-1IDS-1

N C

E C

-1

1G10

MAIN

COMM

FRONT

PAEC-1

ER1

FRONT

HINGE

SIDE

TMGB-1

B.6

B.8

2.2

XM.1XM.1

XM.05XM.05

1G15

COMM

ER2ER3NMCI

TGB-1

FRONT

V S

S -2

A C

A S

-2

ER1

B.6

B.8

2.2

XM.1XM.1

XM.05XM.05

1G15

COMM

B

1G10

MAIN

COMM

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

1/4" = 1'-0"

E N

LA

R

G E

D P

LA

N

S

C O

M M

U N

IC

A

T

IO

N S

ET401

NGZ SSS DRS

12760779

11/18/20

SCALE: 1/4" = 1'-0" ET101-2 B2

COMMUNICATIONS ROOM 1G10

1 3/4" FLAME RETARTDANT PLYWOOD BACKBOARD FROM 6" FROM

FINISHED FLOOR TO BOTTOM TO 8'-6" AFF TO TOP. APPLY TWO

COATS OF WHITE PAINT. DO NOT PAINT OVER PLYWOOD RATING

LABEL.

2 18" WIDE LADDER RACK MOUNTED AT 7'-0" AFF TO BOTTOM AND

REST ON TOP OF EQUIPMENT RACKS.

3 FOR PA SYSTEM TELEPHONE ACCESS MODULE (TAM).

4 4" CONDUIT STUB UPS FROM HANDOLE "HHT1" WITH OUTSIDE

PLANT CABLES THROUGH FLOOR SLAB. TYPICAL FOR 4. STUB-UP

CONDUITS 6" ABOVE THE FLOOR SLAB. PROVIDE GROUNDING

BUSHING ON TOP AND BOND TO TELECOMMUNICATIONS ROOM

GROUND BUS WITH A #6AWG COPPER GROUNDING CONDUCTOR.

REFER TO SHEET ET701 FOR CABLING REQUIREMENTS.

5 BUILDING ENTRANCE PROTECTOR (BEP) ASSEMBLY. MOUNT 5'-0"

AFF TO BOTTOM.

6 DEDICATED WALL SPACE FOR CABLE TV SYSTEM MULTI-TAPS,

SPLITTER, AND AMPLIFIER.

7 EQUIPMENT RACK FOR GFGI TELEPHONE SWITCH.

8 FOUR 4" CONDUIT SLEEVES.

SCALE: 1/4" = 1'-0" ET101-1 A2

COMMUNICATIONS ROOM 1G15

SCALE: 1/4" = 1'-0" ET101-1 A3

COMMUNICATIONS ROOM 1G15

LADDER RACK PLAN

SCALE: 1/4" = 1'-0" ET101-2 B3

COMMUNICATIONS ROOM 1G10

LADDER RACK PLAN

JAS

mec

TOP VIEW

FRONT VIEW

1'-6"

2'-0"

1/8" THICK

2"

1/4" 2"

7/16" DIAMETER

(TYP FOR 10)

5/16" DIAMETER (TYP FOR 36)

POLYAMIDE STANDOFF

INSULATOR

STAINLESS STEEL

BRACKET, 1/8" THICK

NOTES:

A. TGB SHALL MEET ANSI TIA-607 REQUIREMENTS AND BICSI

RECOMMENDATIONS INCLUDING HOLE SIZES, PATTERNS, AND SPACING.

SEE B2/ET702 FOR BONDING

CONNECTIONS TO TGB.

FASTEN TO STRUCTURE

HEX NUT AND WASHER

1 5/8" SQUARE

STEEL CHANNEL

FINISHED CEILING

CABLE TRAY FASTENED

TO STEEL CHANNEL

CABLE TRAY GROUND CLAMP

TYPICAL CONDUIT STUB-OUT

ABOVE CABLE TRAY.

EXTEND CONDUIT TO WITHIN

6" OF CABLE TRAY

FASTEN TO STRUCTURE

HEX NUT AND WASHER

#6 AWG COPPER GROUND

INSULATED GROUNDING BUSHING

2'-5"

4"

1'-6"

POLYAMIDE STANDOFF

INSULATOR (TYPICAL)

1/ 4"

304 STAINLESS STEEL

BRACKET, 1/8" THICK

(TYPICAL)

2"

TOP VIEW

FRONT VIEW

NOTES:

A. TGMB SHALL MEET ANSI TIA-607 REQUIREMENTS HOLE SIZES,

PATTERNS, AND SPACING.

#3/0 TELECOMMUNICATIONS

BONDING CONDUCTOR TO

ELECTRICAL MAIN SERVICE

GROUND. SEE B2/ET702 FOR

GROUNDING DIAGRAM

CONDUIT FITTING AS REQUIRED

CONDUIT HUB GROUND CLAMP

TWO-HOLE LUG

1" CONDUIT

AUDIO/VISUAL WALL BOX

AV

MM

2D,V

AUDIO/VISUAL WALL BOX

TVA

D,F

13 13

AV

FLAT PANEL TV

OR DISPLAY

CABLE TRAY

COMBINATION

POWER/COMMUNICATION

RECESSED FLOOR BOX

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

As indicated

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

ET501

NGZ SSS DRS

12760780

11/18/20

SCALE: NTS C2

TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) DETAIL

SCALE: NTS A2

CABLE TRAY SUPPORT DETAIL

SCALE: NTS A4

TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB)

DETAIL

SCALE: NTS C4

TYPICAL AUDIO/VISUAL WALL BOXES HORIZONTAL RISER

DIAGRAM

SCALE: NTS A5

TYPICAL FLOOR BOX HORIZONTAL

RISER DIAGRAM

1 ROUTE CONDUIT UP THROUGH THE NEAREST WALL CAVITY.

2 CONDUIT TO CABLE TRAY, SIZE AND QUANTITY AS INDICATED FOR

COMBINATION FLOOR BOX.

3 PROVIDE PULL FOX FOR EVERY TWO 90 DEGREE BENDS. PULL BOX SHALL

NOT BE USED IN LIEU OF A 90 DEGREE BEND.

4 COMBINATION POWER/COMMUNICATIONS RECESSED FLOOR BOX WITH

THREE CATEGORY 6 RATED 8 POSITION MODULE JACKS LABELED AS

"DATA" AND ONE CATEGORY 6 RATED 8 POSITION MODULAR JACK LABELED

AS "VOICE".

5 1 1/4" CONDUIT TO CABLE TRAY FOR MULTIMEDIA GFGI CABLES.

6 STUB-OUT CONDUIT INTO THE CABLE TRAY. SEE A2/ET501 FOR DETAIL.

7 1" CONDUIT.

8 1/2" CONDUIT TO PANELBOARD. REFER TO POWER PLANS FOR CIRCUITS.

9 COAXIAL CABLE(S) TO MULTI-TAP DEVICE, SEE A2/ET702 FOR

REQUIREMENTS.

10 THREE 4 PAIR CATEGORY 6 CABLES TO TELECOMMUNICATIONS ROOM.

11 ONE 4 PAIR CATEGORY 6 CABLE TO TELECOMMUNICATIONS ROOM.

12 HORIZONTAL CABLES TO TELECOMMUNICATIONS ROOM. PROVIDE ONE

CATEGORY 6 CABLE FOR EACH 8 POSITION MODULAR JACK SPECIFIED.

13 1" CONDUIT TO CABLE TRAY.

14 MULTIMEDIA WALL BOX, SEE A4/ET503 FOR DETAIL.

JAS

mec

RACK ELEVATION EQUIPMENT CODES

CODE DESCRIPTION

H.48C 48 PORT CATEGORY 6, HORIZONTAL COPPER PATCH PANEL

B.200C 200 PAIR INSULATION DISPLACEMENT CONNECTOR (IDC) BLOCKS ON 89D

STYLE BRACKET FOR INCOMMING CABLE.

B.48F 48 FIBER BACKBONE FIBER OPTIC DISTRIBUTER PATCH PANEL

H.CM HORIZONTAL CABLE MANAGEMENT

V.6.CM DOUBLE SIDED 6" W x 20" D VERTICAL CABLE MANAGEMENT

45RU 7' HIGH, 45RU EQUIPMENT RACK

NOTES:

A. SEE VOICE AND DATA BACKBONE RISER DIAGRAM(S) FOR

BACKBONE CABLE QUANTITIES AND LOCATIONS OF

TERMINATIONS.

B. PROVIDE HORIZONTAL AND BACKBONE PATCH PANEL PORT

QUANTITY TO TERMINATE ALL REQUIRED HORIZONTAL

CABLES PLUS 25% SPARE.

C. QUANTITY OF INSULATION DISPLACEMENT CONNECTOR AS

REQUIRED TO TERMINATE ALL INDICATED BACKBONE

CABLES PLUS 25%.

D. THIS ELEVATION INDICATES FULLY POPULATED RACKS.

PROVIDE PATCH PANELS AS REQUIRED, PLUS INDICATED

SPARE CAPACITY.

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

V.6.CM

V.6.CM

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

V.6.CM V.6.CM45RU 45RU

BOTTOM 15RU RESERVED

SPACE FOR GOVERNMENT

FURNISHED, GOVERNMENT

INSTALLED ELECTRONIC

NETWORKING EQUIPMENT.

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.CM

O.24.F

H.CMH.CM

45RU

ER 1 ER 2 ER 3

O.24F 24 PORT OSP FIBER OPTIC PATCH PANEL

BOTTOM 15RU RESERVED

SPACE FOR GOVERNMENT

FURNISHED, GOVERNMENT

INSTALLED ELECTRONIC

NETWORKING EQUIPMENT.

BOTTOM 15RU RESERVED

SPACE FOR GOVERNMENT

FURNISHED, GOVERNMENT

INSTALLED ELECTRONIC

NETWORKING EQUIPMENT.

H.CM

B.48.F

H.CM

B.200.C

H.CM

B.200.C V.6.CM

45 RU

NMCI

H.CM

H.48.C

V.6.CM

THIS RACK IS RESERVED

FOR NMCI. TERMINATE ALL

NMCI IDENDIFIED

HORIZONTAL CABLES IN

THE ZONE SERVED BY THIS

COMMUNICATIONS ROOM

ON THE PATCH PANEL IN

THIS RACK. REMAINDER OF

RACK IS RESERVED FOR

GOVERNMENT FURNISHED,

GOVERNMENT INSTALLED

NMCE NETWORKING

EQUIPMENT.

H.CM

V.6.CMV.6.CM

RACK ELEVATION EQUIPMENT CODES

CODE DESCRIPTION

H.48C 48 PORT CATEGORY 6, HORIZONTAL COPPER PATCH PANEL

B.100C 100 PAIR INSULATION DISPLACEMENT CONNECTOR (IDC) BLOCKS ON 89D

STYLE BRACKET.

B.24F 24 FIBER BACKBONE FIBER OPTIC DISTRIBUTER PATCH PANEL

H.CM HORIZONTAL CABLE MANAGEMENT

V.6.CM DOUBLE SIDED 6" W x 20" D VERTICAL CABLE MANAGEMENT

45RU 7' HIGH, 45RU EQUIPMENT RACK

NOTES:

A. SEE VOICE AND DATA BACKBONE RISER DIAGRAM(S) FOR

BACKBONE CABLE QUANTITIES AND LOCATIONS OF

TERMINATIONS.

B. PROVIDE HORIZONTAL AND BACKBONE PATCH PANEL PORT

QUANTITY TO TERMINATE ALL REQUIRED HORIZONTAL

CABLES PLUS 25% SPARE.

C. QUANTITY OF INSULATION DISPLACEMENT CONNECTOR AS

REQUIRED TO TERMINATE ALL INDICATED BACKBONE

CABLES PLUS 25%.

D. THIS ELEVATION INDICATES FULLY POPULATED RACKS.

PROVIDE PATCH PANELS AS REQUIRED, PLUS INDICATED

SPARE CAPACITY.

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

V.6.CM

V.6.CM

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

V.6.CM V.6.CM45RU 45RU

BOTTOM 15RU RESERVED

SPACE FOR GOVERNMENT

FURNISHED, GOVERNMENT

INSTALLED ELECTRONIC

NETWORKING EQUIPMENT.

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.CM

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.48.C

H.CM

B.24.F

H.CMH.CM

45RU

ER 1 ER 2 ER 3

BOTTOM 15RU RESERVED

SPACE FOR GOVERNMENT

FURNISHED, GOVERNMENT

INSTALLED ELECTRONIC

NETWORKING EQUIPMENT.

BOTTOM 15RU RESERVED

SPACE FOR GOVERNMENT

FURNISHED, GOVERNMENT

INSTALLED ELECTRONIC

NETWORKING EQUIPMENT.

H.CM

H.48.C

H.CM

H.CM

H.48.C

B.100.C

H.CM

H.48.C

NMCI

H.CM

H.48.C

V.6.CM

THIS RACK IS RESERVED

FOR NMCI. TERMINATE ALL

NMCI IDENDIFIED

HORIZONTAL CABLES IN

THE ZONE SERVED BY THIS

COMMUNICATIONS ROOM

ON THE PATCH PANEL IN

THIS RACK. REMAINDER OF

RACK IS RESERVED FOR

GOVERNMENT FURNISHED,

GOVERNMENT INSTALLED

NMCE NETWORKING

EQUIPMENT.

45RU

H.CM

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

NTS

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

ET502

NGZ SSS DRS

12760781

11/18/20

SCALE: NTS A3

RACK ELEVATION - MAIN COMMUNICATIONS ROOM

SCALE: NTS A5

RACK ELEVATION - ROOM 1G15

JAS

mec

FINISHED CEILING

SPEAKER BAFFLE

12" DIAMETER MAXIMUM

MOUNTING RAILS

T-BAR OR FRAMING

MEMBER

FLEXIBLE CONDUIT. 1/2" DIA. MINIMUM

SPEAKER JUNCTION BOX

CONDUIT TO NEXT

SPEAKER JUNCTION BOX

PWB BOX

STUD

(2) STUD BRACKET (2 - #

6-32x1/4" PAN HEAD SCREWS)

WHITE COVER (4 PAINTED #6-32 x 3/4"

OVAL HEAD SCREWS)

1/2" - 5/8" WALL

THICKNESS

WALL OPENING: 11" x 5-1/4"

ACCESSORY LOW-VOLTAGE CONDUIT ENTRY

BOX (2 - #6-32 x 1/4" PAN HEAD SCREWS)

STUD MOUNTING HARDWARE BY

CUSTOMER (#6 SCREW 1/2"x1"

STAPLE, OR NAIL)

16" STUD CENTERS

DIRECT-TO-STUD

MOUNTING HOLES

BACK BOX (4 - #

6-32 x 1/4" PAN

HEAD SCREWS)

(3) BLOCK-OFF PANEL (2 - #6-32 x

1/4" PAN HEAD SCREWS)

COVER CENTER SECTION (2 - #6-32 x 1/2"

UNDERCUT FLAT HEAD SCREWS)

VIEW "A"

3.6310.94

BACK BOX WITH DUPLEX

RECEPTACLE

LOW-VOLTAGE ENTRY

BOX, PROVIDE JACKS AS

INDICATED ON PLANS

LOW-VOLTAGE ENTRY BOX AND AC OUTLET BOX

MAY BE MOUNTED ON TOP OR BOTTOM AS

INDICATED.

VIEW "A"

WALL

MOUNTED

SURFACE 3.55 FROM

WALL

MOUNTED

SURFACE

CL

4.40

4.771.79

2.16

1.42.58

OPPOSITE SIDE IS MIRROR IMAGE

7.02

5.23

7.39

CL

(8) 1/2" KNOCKOUTS

1" & 1-1/4" KNOCKOUT

1" & 1-1/4" KNOCKOUT

1" KNOCKOUT

AC OUTLET OPENING

INSERT OPENING

1" x 2" OVAL KNOCKOUT CENTERED ON

BLOCK-OFF PANEL

LOW-VOLTAGE ENTRY

BOX, PROVIDE JACKS AS

INDICATED ON PLANS

BACK BOX WITH DUPLEX

RECEPTACLE

RG-6 COAXIAL CABLE TO THE LINE TAP DEVICE LOCATED

IN THE COMMUNICATIONS ROOM. SEE A2/ET702 FOR

CONNECTION DIAGRAM. ROUTE THROUGH CABLE TRAY.

5" SQUARE X 2 7/8" DEEP BOX WITH A 1 1/2"

EXTENSION AND TWO GANG PLASTER RING.

PROVIDE MODULAR FACEPLATE WITH

INSERTS AS REQUIRED. LABEL AS INDICATED.

"F" TYPE COAXIAL CONNECTOR.

DUPLEX RECEPTACLE

1/2" CONDUIT FOR

POWER WIRING.

120V CIRCUIT

CONDUCTORS.

TV

TV

1" CONDUIT TO CORRIDOR CABLE TRAY.

SEE A2/ET501 FOR DETAIL.

DATA

CATEGORY 6 RATED, 8 POSITION

MODULAR JACK.

1 1/2" MIN.

(1) 4-PAIR CATEGORY 6 RATED CABLE TO THE

COMMUNICATIONS ROOM. CONNECT TO

HORIZONTAL PATCH PANEL.

FED FROM LN1-1

FATP-2

TYPICAL FOR:

1. NURSE CALL EQUIPMENT CABINETS

2. FIRE ALARM PANELS

3. INTRUSION DETECTION SYSTEM

EQUIPMENT CABINETS

4. ACCESS CONTROL SYSTEM EQUIPMENT

CABINETS

5. VIDEO SURVEILLANCE SYSTEM

EQUIPMENT CABINETS

6. PUBLIC ADDRESS SYSTEM EQUIPMENT

CABINETS

7. MEDICAL GAS ALARM PANELS

PANEL FROM WHICH

EQUIPMENT IS SERVED,

1/8" HIGH LETTERS

EQUIPMENT NAME,

1/4" HIGH LETTERS

COLOR CODE:

1. NORMAL: BLACK FACE WITH

WHITE LETTERS

A. PROVIDE LAMINATED PLASTIC NAMEPLATES FOR ALL EQUIPMENT

ENCLOSURES AS INDICATED. NAMEPLATES SHALL BE MELAMINE PLASTIC,

0.125 INCH THICK WITH FACE AND CORE COLORS AS INDICATED. SURFACE

SHALL HAVE A MATTE FINISH. CORNERS SHALL BE SQUARE AND EDGES

SHALL BE BEVELED. ACCURATELY ALIGN LETTERING AND ENGRAVE INTO

THE CORE.

B. NAME PLATE WIDTH SHALL BE 2 1/2". PROVIDE ADDITIONAL LINES OF TEXT

AND INCREASE HEIGHT AS REQUIRED.

GENERAL NOTES:

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

As indicated

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

ET503

NGZ SSS DRS

12760782

11/18/20

SCALE: NTS C2

CEILING MOUNTED SPEAKER DETAIL

SCALE: NTS A4

AUDIO/VISUAL WALL BOX DETAIL

SCALE: NTS C4

FLAT PANEL TELEVISION OUTLET DETAIL

SCALE: NTS C5

COMM AND FIRE ALARM EQUIPMENT

IDENTIFICATION PLATE DETAIL

JAS

mec

HORIZONTAL CABLES TO

PATCH PANEL(S) IN

TELECOMMUNICATION ROOM

CABLE TRAY

STUB OUT CONDUIT TO CABLE

TRAY. SEE A2/ET501 FOR DETAIL

PULL BOX AS REQUIRED FOR

EVERY TWO 90 DEGREE BENDS

IN EACH CONDUIT RUN

FINISHED CEILING

NEAREST INTERIOR WALL

EMT

FINISHED FLOOR

SLAB ON GRADE

PROVIDE SIZE AND QUANTITY OF

CONDUITS INDICATED FOR EACH

FLOOR BOX. PROVIDE A PULL

STRING IN EACH CONDUIT FOR

FUTURE CABLE PULLS.

SCHEDULE 40 PVC

2" FLEXIBLE CONDUIT

FURNITURE

SYSTEM

RACEWAY

MODULAR FURNITURE SYSTEM

HORIZONTAL

CABLE TO OUTLETS

1" SCREW PLUG

2" SCREW PLUG

FLOOR BOX PLAN VIEW

HORIZONTAL

CABLE BUNDLE

VERTICAL WIRE CHASE

PROVIDED WITH MODULAR

FURNITURE

CONDUIT FROM CABLE TRAY

TO VERTICAL WIRE CHASE.

SEE TELECOMMUNICATIONS

PLANS FOR SIZE.

CABLE TRAY

HORIZONTAL CABLE BUNDLE.

PROVIDE QUANTITY OF CABLES

AS REQUIRED TO SERVE ALL

VOICE/DATA OUTLETS INDICATED

FOR EACH FURNITURE FEED.FINISHED CEILING

MODULAR LAB/PHARMACY

FURNITURE SYSTEM

TYPICAL VOICE/DATA

OUTLET

DIVIDED RACEWAY PROVIDED WITH

MODULAR FURNITURE

FINISHED FLOOR

KNEE SPACE

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

NTS

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

ET504

NGZ BTB DRS

12760783

11/18/20

SCALE: NTS C3

MODULAR FURNITURE VOICE/DATA FEED DETAIL

SCALE: NTS A3

MODULAR PHARMACY/LAB ABOVE CEILING FURNITURE FEED DETAIL

JAS

mec

FIRST FLOORER3ER2ER1ER3ER2ER1 RM. 1G15

RM 1G10 / RM 1G15 - FSM.24

RM 1G10 / RM 1G15 - C.100

RM. 1G10

HHT1 HHT2

ROOF

2BEP

RM. X128

RM 1G10 / RM X128 - FSM.24

RM 1G10 / RM X128 - C.100

EXISTING

RACK

EXISTING

RACK

HHFC402 / RM 1G10 - FSM.24

RP589-A1-A / 1G10 - C.50

EXISTING OSP FIBER

OPTIC CABLES

NMCI

SEE RACK ELEVATION

A5/ET502

SEE RACK ELEVATION

A3/ET502

4-WAY

CONCRETE

ENCASED

DUCTBANK

4-WAY

CONCRETE

ENCASED

DUCTBANK

4-WAY

CONCRETE

ENCASED

DUCTBANK

2-WAY

CONCRETE

ENCASED

DUCTBANK

EXISTING OSP COPPER

CABLES

RP589-A11

2-WAY

CONCRETE

ENCASED

DUCTBANK

HHFC402

3 4

5 6

NMCIPH SW

GFGI

TELEPHONE

SWITCH

ER2 / PHSW - FSM.12

BEP / ER2 - C.50

GFGI MAIN CROSS

CONNECT

DETAIL CODES:

8P 8 POSITION MODULAR JACK, -

B BLANK INSERT-

MFP MODULAR FACE PLATE-

LBL LABEL SPACE-

WS WALL PHONE MOUNTING STUD-

WFP WALL PHONE FACE PLATE-

1"C 1" CONDUIT TO NEAREST CABLE TRAY-

3/4"C 3/4" CONDUIT TO NEAREST CABLE

TRAY

DETAIL NOTES:

A. ALL BACK BOXES SHALL BE 5" SQUARE X 2 1/8" DEEP WITH SINGLE GANG PLASTER RING UNLESS OTHERWISE INDICATED. BACK BOXES INSTALLED IN CMU WALL SHALL BE 4 11/16" SQUARE BY 2 1/8" DEEP

B. PROVIDE BLANK INSERT FOR ALL UNUSED FACEPLATE PORTS.

C. PROVIDE (1) CATEGORY 6, 4 PAIR HORIZONTAL CABLE FOR EACH 8 POSITION MODULAR JACK FROM THE

OUTLET TO HORIZONTAL PATCH PANEL IN THE INDICATED COMMUNICATIONS ROOM.

D. SEE A2/ET501 FOR CONDUIT TO CABLE TRAY STUB OUT DETAIL.

E. PROVIDE PULL STRING FOR FUTURE USE IN EACH CONDUIT BETWEEN CABLE TRAY AND BACKBOX.

3/4"C 1"C 3/4"C

LBL LBL

LBLLBL

8P

(TYP)

MFP

MFP

WFP

8P

WS

WS

8P

(TYP)

HC HORIZONTAL CABLE(S)-

HC HC HC

WAP

B

(TYP)

NMCI

FMP 8P

(TYP)

MHC

B

DI

MFB

(SEE DETAIL C3/ET504 FOR

FURNITURE FEED REQUIREMENTS)

MFR

LBL

8P

(TYP)

LBL

MFP

B

MHCO

LF PF

(SEE DETAIL A3/ET504 FOR VERTICAL

CHASE FEED REQUIREMENTS)

DI DECORA STYLE MODULAR INSERT-

MFR MODULAR FURNITURE RACEWAY

SYSTEM PROVIDED WITH MODULAR

FURNITURE

FMP MOUNTING PLATE WITH DECORA SIZE

OPENING PROVIDED WITH MODULAR

FURNITURE

MHC HORIZONTAL CABLES ROUTED

THROUGH FURNITURE RACEWAY

SYSTEM TO FLOOR BOX

MHCO HORIZONTAL CABLES ROUTED

THROUGH MODULAR FURNITURE

RACEWAY AND VERTICAL UTILITY

CHASE TO ABOVE CEILING CONDUIT

AS INDICATED

FMP 8P

(TYP)

MHW

B

DI

MFA

MHW HORIZONTAL CABLES ROUTED

THROUGH FURNITURE RACEWAY

SYSTEM TO WALL BOX

PP

B

8P

(TYP)

HC

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

SHEET NOTES:

NOTES:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

As indicated

V O

IC

E

/D A

T A

B A

C K

B O

N E

R

IS

E R

D

IA

G R

A M

ET701

NGZ SSS DRS

12760784

11/18/20

SCALE: NTS A4

VOICE/DATA BACKBONE RISER DIAGRAM

1 TYPICAL CONDUIT STUB UP THROUGH FLOOR SLAB. SEE

ENLARGED COMMUNICATIONS PLAN FOR QUANTITIES AND

LOCATIONS.

2 BUILDING ENTRANCE PROTECTOR AS REQUIRED TO TERMINATE

ALL COPPER PAIRS PLUS 25% SPARE CAPACITY.

3 EXISTING TERMINATING EQUIPMENT.

4 PROVIDE 10' OF SLACK CABLE. TEST CABLE AND LEAVE

UNTERMINATED. CABLE WILL BE TERMINATED BY BASE

TELECOMMUNICATIONS SUPPORT DIVISION.

5 FIBER OPTIC SPLICE CLOSURE.

6 PROVIDE 100' OF SLACK CABLE. TEST CABLE AND LEAVE

UNTERMINATED. CABLE WILL BE TERMINATED BY BASE

TELECOMMUNICATIONS SUPPORT DIVISION.

A. ROUTE EACH BACKBONE FIBER OPTIC CABLE THROUGH (1) 1 1/4"

INNERDUCT.

B. ALL BACKBONE CABLING SHALL BE ROUTED IN CABLE TRAY.

C. ALL WORK PERFORMED WITHIN TELECOMM HANDHOLES AND PEDESTALS

SHALL BE COORDINATED WITH CONTRACTING OFFICER.

SCALE: NTS C4

TYPICAL VOICE / DATA HORIZONTAL RISER DIAGRAM

JAS

mec

FIRST FLOOR

ROOF

RM. 1G15

TGB-1

RM. 1G10

TMGB-1

22 33

6 EXISTING

GROUND BUS BAR

RM. X128

FIRST FLOOR

ROOF

LT-1

RM. 1G10

8 9

RM. 1G15

LT-2

EXISTING POLE

RG-6 DROP CABLE ROUTED

THROUGH CABLE TRAY

RG-11 TRUNK CABLE

TV OUTLET. TV OUTLET

ALSO LOCATED WITHIN

AUDIO/VISUAL WALL BOX.

REFER TO PLANS FOR

SPECIFIC MULTIMEDIA

WALL BOX TYPE. (TYPICAL)

LT-1 LINE TAP

NUMBER

DIRECT

CONNECTION

TO NEXT LINE

TAP

DIRECT CONNECTION

TO NEXT LINE TAP OR

SPLITTER

TV

AV

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

NTS

C O

M M

U N

IC

A

T

IO

N S

R

IS

E R

D

IA

G R

A M

ET702

NGZ SSS DRS

12760785

11/18/20

SCALE: NTS B2

TELECOMMUNICATIONS GROUNDING RISER

SCALE: NTS A5

TELEVISION SYSTEM RISER DIAGRAM AND LINE TAP SCHEDULES

SCALE: NTS A2

TYPICAL LINE TAP CONNECTION DIAGRAM

1 4" CONDUIT STUB-UP FROM HANDHOLE "HHT1". SEE B2/ET401 FOR STUB

UP LOCATION.

2 #6 AWG INSULATED COPPER BONDING CONDUCTOR TO EQUIPMENT

RACK(S).

3 #6 AWG INSULATED COPPER BONDING CONDUCTOR TO NEAREST

VERTICAL STRUCTURAL STEEL MEMBER.

4 #6 AWG INSULATED COPPER BONDING CONDUCTOR TO CABLE TRAY

AND/OR LADDER RACK.

5 1"C - #3/0 AWG INSULATED COPPER TELECOMMUNICATIONS BONDING

BACKBONE CONDUCTOR.

6 #3/0 AWG INSULATED COPPER IN 1" CONDUIT TO GROUND BUS IN MAIN

PANELBOARD "MDP1".

7 RG-11 COAXIAL TRUNK CABLE.

8 SEE A2/ET702 FOR TYPICAL LINE TAP CONNECTION DIAGRAM.

9 SPLITTER AS REQUIRED.

10 COAXIAL SURGE PROTECTIVE DEVICE. BOND TO TELECOMMUNICATIONS

ROOM GROUND BUS WITH A #6 AWG COPPER GROUNDING CONDUCTOR.

11 INCOMING CABLE NOT IN CONTRACT.

12 ADJUSTABLE GAIN AMPLIFIER AS REQUIRED.

LINETAP LT-1

TV LOCATION

1AC1B

1AC1B

1G03

LINETAP LT-2

TV LOCATION

1A09

1G22

JAS

mec

PAGING SYSTEM PRIORITY SCHEDULE

PRIORITY

NUMBER PAGING FUNCTION

PAGING SYSTEM

ZONING SCHEDULE

ZONE

NUMBER PAGING FUNCTION 1 ALL CALL PAGE

2 ZONE PAGING CLINIC NORTH - GENERALZ1

CLINIC SOUTH - GENERALZ2

PA SYSTEM OF OPERATION DESCRIPTION

ACCESS TO THE PAGING ZONES WILL BE PROVIDED THROUGH THE TELEPHONE SYSTEM AT SELECTED TELEPHONE INSTRUMENTS AS DIRECTED BY THE CONTRACTING OFFICER. INDIVIDUAL ZONE PAGING AND A COMMON "ALL CALL" ZONE SHALL BE PROVIDED. ACCESS TO "ALL CALL" PAGING WILL BE THROUGH THE TELEPHONE SYSTEM. ALL ZONES SHALL HAVE THE CAPABILITY TO MAKE ANNOUNCEMENTS IN ZONES Z1, Z2, Z3, AND Z4. KEYING OF THE MICROPHONE WILL ACTIVATE AN "ALL CALL" PAGE THAT WILL OVERRIDE ANY ZONE PAGING. ZONE PAGING IS ACCESSIBLE THROUGH THE TELEPHONE SYSTEM BY DIALING A SPECIFIC EXTENSION AT SELECTED TELEPHONE INSTRUMENTS. THE SYSTEM SHALL ALLOW SIMULTANEOUS PAGING ANNOUNCEMENTS IN MULTIPLE ZONES. THE SYSTEM SHALL HAVE A DIGITAL QUEING SYSTEM THAT SHALL RECORD, STORE, AND DISTRIBUTE ALL PAGES ON A GIVEN ZONE IF SIMULTANEOUS PAGES ARE MADE. ALL CALL PAGES SHALL HAVE PRIORITY OVER ZONE PAGES. AFTER ZONE PAGE IS COMPLETE, ALL CALL PAGES MAY BE BROADCAST. THE PUBLIC ADDRESS SYSTEM SHALL BE ZONED AS INDICATED. ALL ZONES SHALL BE CAPABLE OF PLAYING THE MP3 PLAYER OR AM/FM TUNER. ALL ZONES SHALL ALLOW FOR ZONE PAGING AS WELL AS ALL CALL WITH TWO PRIORITY LEVELS. WHEN ZONES ARE DISTRIBUTING MUSIC, PRIORITY TWO CALLS SHALL INTERRUPT THE MUSIC, AND THE PRIORITY TWO SIGNAL WILL OVERRIDE. PRIORITY ONE SHALL OVERRIDE ALL PRIORITY TWO CALLS.

THE SYSTEM SHALL INTERFACE WITH THE FIRE ALARM/MASS NOTIFICATION SYSTEM. ALL PRIORITY ONE AND

TWO CALLS SHALL BE MUTED WHEN FIRE ALARM/MASS NOTIFICATION CALLS ARE ACTIVE.

PHARMACYZ3

FIRST FLOOR

ROOF

TAM

PAEC-1

AUDIO OUTPUT EXPANDER

TO DEDICATED RECEPTACLE

(SEE A2/EP401 FOR LOCATION)

PLUG STRIP

AUDIO INPUT EXPANDER

AM/FM TUNER

RM. 1G10

VOICE MESSAGE SERVER

NETWORK SWITCH

ANTENNA ON ROOF. SEE

SHEET EQ103 FOR

LOCATION.

ZONE Z1 AMP

ZONE Z2 AMP

ZONE Z3 AMP

8S

S

Z1

Z2

TO

ADDITIONAL

SPEAKERS

V

S Z3

DENTAL - GENERALZ4

ZONE Z4 AMPS

Z4

10M

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

NTS

P U

B

LI

C A

D D

R E

S S

S Y

S T

E M

R

IS

E R

D

IA

G R

A M

S

ET703

NGZ SSS DRS

12760786

11/18/20

SCALE: NTS A4

PUBLIC ADDRESS RISER DIAGRAM

1 TYPICAL NETWORKED REMOTE VOLUME CONTROL.

2 TELEPHONE ACCESS MODULE FOR TELEPHONE SYSTEM

INTERFACE. PROVIDE ACCESS MODULES AS NECESSARY FOR

PAGING OF EACH ZONE INDEPENDENTLY, ALL CALL, AND PRIORITY

PAGING.

3 (4) 4 PAIR CATEGORY 6 RATED CABLE TO THE RACK MOUNTED

PATCH PANEL IN COMMUNICATIONS ROOM 1G10.

4 NETWORK CABLE FOR VOLUME CONTROL. ROUTE IN CABLE TRAY.

5 CAT 6 PATCH CORD.

6 3/4"C WITH ANTENNA WIRING AS REQUIRED.

7 3/4" CONDUIT WITH SPEAKER WIRING TO ADDITIONAL SPEAKERS.

REFER TO COMMUNICATIONS PLANS FOR QUANTITY OF SPEAKERS

IN EACH ZONE.

8 WALL MOUNTED, NEMA TYPE 1 DOUBLE HINGED RACK WITH ZONE

AMPLIFIERS. RACK SHALL HAVE THREE COMPONENTS: FRONT

DOOR, CENTER SECTION, AND WALL SECTION. CENTER SECTION

SHALL PROVIDE VENTILATED SIDES, 19 INCH RACK MOUNTING PER

TIA UNIVERSAL SPACING AND IS ACCESSED THROUGH THE FRONT

DOOR OR SWING THE REAR SECTION AWAY FROM THE WALL FOR

REAR ACCESS. WALL SECTION PROVIDES FOR CONDUIT/CABLE

ENTRY WITH KNOCKOUTS. FRONT DOOR SHALL PROVIDE 180

DEGREE SWING AND HAVE KEY OPERATED LOCKING MECHANISM.

RACK SHALL HAVE BLACK POWDER COAT FINISH AND PROVIDE

MOUNTING SPACE FOR 32 RACK UNITS. RACK SHALL HAVE

DIMENSIONS OF 24" WIDE x 60" HEIGHT X 25" DEPTH AND SHALL BE

HINGED ON THE LEFT SIDE. MOUNT ON WALL AT 72" AFF TO TOP.

9 3/4" CONDUIT WITH SPEAKER WIRING AS REQUIRED.

10 MICROPHONE AT EQUIPMENT RACK FOR TESTING PURPOSES.

JAS

mec

NCEC

TYPICAL

TOILET

STATION

TYPICAL

EMERGENCY

PUSH BUTTON

STATION WITH

PULL CORD

A. THIS DIAGRAM INDICATES NURSE CALL SYSTEM DEVICES CONNECTED IN A TYPICAL CONFIGURATION. REFER TO THE COMMUNICATIONS FLOOR PLAN FOR THE ACTUAL QUANTITY AND LOCATION FOR ALL NURSE CALL DEVICES.

B. UNLESS OTHERWISE DEPICTED, ALL CONDUITS SHALL STUB OUT TO THE NEAREST CABLE TRAY. SEE A2/ET501 FOR CONDUIT

TO CABLE TRAY TERMINATION DETAIL.

C. CONDUIT SIZES INDICATED ARE MINIMUM REQUIREMENTS. INCREASE CONDUIT SIZE(S) AS REQUIRED FOR REQUIRED NURSE

CALL SYSTEM WIRING.

D. ROUTE ALL NURSE CALL SYSTEM WIRING THROUGH THE CABLE TRAY SYSTEM.

E. SEE SHEET ET704 FOR NURSE CALL EQUIPMENT CABINET SCHEDULES.

NOTES: (A5/ET704)

TYPICAL

ANNUNCIATOR

STATION

NA TP NP

3 4 4 4

CABLE TRAY

TYPICAL

CEILING

MOUNTED

DOME LIGHT

NC

TYPICAL

WALL

MOUNTED

DOME LIGHT

NW

TYPICAL

CEILING

MOUNTED

ZONE LIGHT

ZC

TYPICAL

WALL

MOUNTED

ZONE LIGHT

ZW

TYPICAL

DRESSING

ROOM

PULLCORD

STATION

DP

4 4 4 4 4

TYPICAL

CODE BLUE

STATION

CB

TYPICAL

EMERGENCY

PUSH BUTTON

STATION

PB

RM. 1G10

STAFF

ASSIST

WIRELESS

RECEIVER

SA R

STAFF

ASSIST

WIRED

WALL

MOUNTED

STATION

SA

4 4

DONALD R SELLERS

REG. NO. 110645

EXPIRES 12−31−22 RR

ENGI

S

E D

N

OI

T

UBI

RTSIDSNOITACINUMM

O

C D

E R

E T

SI

GE

DDCR

KEY NOTES 00

NOTES:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

F R

E N

C H

C R

E E

K A

M B

U

LA

T O

R Y

C A

R E

C

LI

N

IC

A D

D

IT

IO

N

A

LT

E

R A

T

V

IR

G

IN

IA

A V

E N

U E

JA

C

K S

O N

V

IL

LE

, N

C

N O

R F

O

LK

, V

IR

G

IN

IA

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

, A T

LA

N

T

IC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1430035

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

FOR OFFICIAL USE ONLY

4750 New Broad Street

Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

TBD

JGG / RSF

EJA

Approved by JOANNE KRAUSE, Director of Medical Facilities

Program Office, via Email

C :\U se rs

\m ec

\D oc um en ts \4

0-

B

LD

G -1

-E

_r

_m ec rlf ae .c om .rv t

/3

0/

:4 2:

P

M

NTS

N U

R S

E C

A

LL

S C

H E

D U

LE

A

N D

R

IS

E R

D

IA

G R

A M

ET704

NGZ SSS DRS

12760787

11/18/20

NURSE CALL EQUIPMENT CABINET NCEC-1

ROOM

NUMBER

DEVICE

TYPE

DOME LIGHT

IDENTIFIER CONNECTED ZONE/DOME LIGHT

CONNECTED

ANNUNCIATOR STATION

1C02 CB D-1C02 NA-1C01

1C02 CB D-1C02 NA-1C01

1C02 CB D-1C02 NA-1C01

1C05 DP D-1C05 Z-1CC1 NA-1C01

1C02 NC D-1C02 Z-1CC1 NA-1C01

1C04 NC D-1C04 NA-1C01

1C05 NC D-1C05 Z-1CC1 NA-1C01

1C02 NP D-1C02 NA-1C01

1C02 NP D-1C02 NA-1C01

1C02 NP D-1C02 NA-1C01

1C10 SA D-1C10, Z-1DC5, Z-1DC3 NA-1C01

1C10 SA D-1C10, Z-1DC5, Z-1DC3 NA-1C01

1C12 SA D-1C12, Z-1DC5, Z-1DC3 NA-1C01

1C12 SA D-1C12, Z-1DC5, Z-1DC3 NA-1C01

1C04 TP D-1C04,Z-1CC1 NA-1C01

1CC1 ZC Z-1CC1 NA-1C01

1D05 CB D-1D05, Z-1DC1, Z-1DC3 NA-1D01

1C04 NC D-1C12 NA-1D01

1C04 NC D-1C10 NA-1D01

1D05 NC D-1D05 NA-1D01

1D15 NC D-1D15 NA-1D01

1D17 NC D-1D17 NA-1D01

1D27 NC D-1D27 Z-1DC1 NA-1D01

1D27A NC D-1D27A Z-1DC1 NA-1D01

1D29 NC D-1D29 NA-1D01

1D05 NP D-1D05, Z-1DC1, Z-1DC3 NA-1D01

1A06 NW D-1A06 NA-1D01

1A08 NW D-1A08 NA-1D01

1A06 TP D-1A06,Z-1AC3 NA-1D01

1A06 TP D-1A06,Z-1AC3 NA-1D01

1A06 TP D-1A06,Z-1AC3 NA-1D01

1A06 TP D-1A06,Z-1AC3 NA-1D01

1A08 TP D-1A08,Z-1AC3 NA-1D01

1A08 TP D-1A08,Z-1AC3 NA-1D01

1D15 TP D-1D15,Z-1DC3 NA-1D01

1D17 TP D-1D17,Z-1DC3 NA-1D01

1D27A TP D-1D27A,D-1D27,Z-1DC1 NA-1D01

1D29 TP D-1D29,Z-1DC1 NA-1D01

1AC3 ZC Z-1AC3 NA-1D01

1CC6 ZC Z-1CC6 NA-1D01

1DC1 ZC Z-1DC1 NA-1D01

1DC3 ZC Z-1DC3 NA-1D01

1DC3 ZC Z-1DC3 NA-1D01

1DC5 ZC Z-1DC5 NA-1D01

1E17 CB D-1E17, Z-1EC4, Z-1EC3 NA-1E01

1E26 CB D-1E26, Z-1EC4, Z-1EC3, Z-1EC1 NA-1E01

1E27 CB D-1EC4, Z-1EC4, Z-1EC1 NA-1E01

1F01 CB D-1F01, Z-1EC5, Z-1EC4 NA-1E01

1E14 NC D-1E14 NA-1E01

1E17 NC D-1E17 NA-1E01

1E26 NC D-1E26 NA-1E01

1E27 NC D-1E27 NA-1E01

1E43 NC D-1E43 NA-1E01

1F01 NC D-1F01D NA-1E01

1F01 NC D-1F01C NA-1E01

1F01 NC D-1F01B NA-1E01

1F01 NC D-1F01A NA-1E01

1F01 NC D-1F01 NA-1E01

1F01 NC D-1F01 NA-1E01

1G21 NC D-1G17 NA-1E01

1E17 NP D-1E17, Z-1EC4, Z-1EC3 NA-1E01

1E26 NP D-1E26, Z-1EC4, Z-1EC3, Z-1EC1 NA-1E01

1E27 NP D-1EC4, Z-1EC4, Z-1EC1 NA-1E01

1F01 NP D-1F01, D-1F01D, Z-1EC5, Z-1EC4 NA-1E01

1F01 NP D-1F01, D-1F01C, Z-1EC5, Z-1EC4 NA-1E01

1F01 NP D-1F01, D-1F01A, Z-1EC5, Z-1EC4 NA-1E01

1F01 NP D-1F01, D-1F01B, Z-1EC5, Z-1EC4 NA-1E01

1E14 TP D-1E14,Z1EC4,Z-1EC3 NA-1E01

1E43 TP D-1E43 NA-1E01

1G21 TP D-1G21,Z-2GC4,Z-1EC5,Z-1EC4,Z-1EC3 NA-1E01

1EC1 ZC Z-1EC1 NA-1E01

1EC1 ZC Z-1EC1 NA-1E01

1EC3 ZC Z-1EC3 NA-1E01

1EC4 ZC Z-1EC4 NA-1E01

1EC4 ZC Z-1EC4 NA-1E01

1EC5 ZC Z-1EC5 NA-1E01

1GC4 ZC Z-1GC4 NA-1E01

SCALE: NTS A5

TYPICAL TONE-VISUAL NURSE CALL SYSTEM RISER DIAGRAM

1 TYPICAL NURSE CALL SYSTEM EQUIPMENT CABINET.

2 PROVIDE INSULATED GROUNDING BUSHING FOR CONDUIT TERMINATION AT

CABLE TRAY.

This is the start of the file's text. The full file is on GovTribe.