This document package includes an electrical drawing and related federal contract opportunity. The electrical drawing depicts the first floor telecommunications and fire alarm plan for Building 345 at Naval Station Newport, and provides notes regarding installation of telephone, data, and fire alarm cabling.

The associated federal contract opportunity is a solicitation for a Design-Build/Design-Bid-Build, Indefinite Delivery/Indefinite Quantity Multiple Award Construction Contract for general construction services at Naval Submarine Base New London in Connecticut and Naval Station Newport in Rhode Island. The solicitation was issued by the Department of the Navy Naval Facilities Engineering Command for an IDIQ MACC with an indefinite quantity of construction projects to be awarded over the life of the contract.

View the file

Other files

File Type Posted
21R0078 0018.pdf PDF
21R0078 0017.pdf PDF
21R0078 0016.pdf PDF
PPI 196 Photos.pdf PDF
21R0078 0015.pdf PDF
Site Visit Attendance Log.JPG JPG image
21R0078 0014.pdf PDF
21R0078 0013.pdf PDF
Attachment A - Construction and Design Experience Project Data Sheet 10-12.docx DOCX document
21R0078 0012.pdf PDF
SECNAV FORM 5512-NSNPT - JUL 2019.pdf PDF
SECNAV 5512 exp 2024 TEMPLATE.pdf PDF
21R0078 0011.pdf PDF
Attachment A - Construction and Design Experience Project Data Sheet.docx DOCX document
21R0078 0010.pdf PDF
21R0078 0009.pdf PDF
B345_CommsInfo.pdf PDF
21R0078 0008.pdf PDF
21R0078 0007.pdf PDF
21R0078 0006.pdf PDF
Attachment C Con Des Exp Proj Data Standard.pdf PDF
NAVSTA soil management plan.pdf PDF
01 31 23.13 20 eCMS.docx DOCX document
21R0078 0005.pdf PDF
21R0078 0004.pdf PDF
SECNAV FORM 5512-NSNPT - DEC 2019.pdf PDF
21R0078 0003.pdf PDF
21R0078 0001.pdf PDF
21R0078 0002.pdf PDF
PPQ.pdf PDF
PPI Log.xlsx XLSX spreadsheet
Construction Des Project Data Sheet.pdf PDF
Bldg 344 Design Build RFP.pdf PDF
Price Schedule 7-3-21.docx DOCX document
21R0078 NPT NLON RFP.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4 1311 14 159876531 10 12

A

C

B

D

E

UV

UV

UV

UV UV UV

UV

PTAC PTAC

PTAC

PTAC

FIN T FIN TFIN T

F I N

T

F I N

T

COMPUTER

CENTER

CORRIDOR

STAIR 2

ST2-1

STAIR 3

ST3-1

STAIR 1

ST1-1

STORAGE

SUPPLY

STORAGE

106A

VTC

SUPR

101A

QUARTER

DECK

VENDING

100A

ELECTRICAL

CLASSROOM

SUPPLY OFFICE

VTC/CONF

DRILL DECK

VEST

109A

24 SF

VEST

110A

29 SF

MEN

176 SF

WOMEN

187 SF

VEST.

56 SF

CG

37 SF

TELECOM

48 SF

FIRST FLOOR PLAN

SCALE: 1/8"=1'-0"

110cd

P

P

75cd

110cd 75cd

75cd

75cd

75cd

75cd

FCP

F

75cd

P

75cd

DN

SCALE: 1/8"=1'-0"

BASEMENT MECHANICAL ROOM

R/F

135°

3-4" CONDUIT SLEEVES

TO 2ND FLOOR FOR DATA

CABLING AND NMCI

SERVICE CABLE. REFER

TO DRAWING E-12 FOR

FURTHER INFORMATION.

4"x4" VERTICAL WIREWAY

FOR TELEPHONE CABLING.

REFER TO DRAWING E-12

FOR FURTHER INFORMATION.

75cd

P

75cd

EXISTING CONDUIT SLEEVE TO CRAWL

SPACE BELOW TO REMAIN FOR NEW

TELEPHONE CABLING.

CORE DRILL AND PROVIDE NEW

CONDUIT SLEEVE TO EXISTING CRAWL

SPACE BELOW FOR INSTALLATION OF

NEW NMCI CABLING.

W W

W

W

SEE NOTE #5

(TYPICAL)

2-4" CONDUIT SLEEVES

ABOVE CEILING FOR

TELEPHONE/DATA CABLING

2-4" CONDUIT SLEEVES

ABOVE CEILING FOR

TELEPHONE/DATA CABLING

P D

NEW LOCATION OF EXISTING FIRE ALARM

MASTER BOX AND BEACON. PROVIDE NEW

FIRE ALARM CABLING. EXTEND EXISTING

CONDUIT TO NEW LOCATION AS REQUIRED.

CONNECT EXISTING FIRE ALARM BEACON TO

EXTERIOR LIGHTING CIRCUIT (CONSTANT ON,

CONNECT AHEAD OF TIMECLOCK CONTROL)

P

P

SEE NOTE #7

PB

PB

PROVIDE NEW PULLBOX TO

INTERFACE WITH EXISTING CONDUITS

(4-4"C.) TO MANHOLE SYSTEM.

REMOVE EXISTING PULLBOX AND

RECONNECT ALL EXISTING AND NEW

CONDUITS TO NEW PULLBOX.

P B

EXISTING CONDUITS (4-4"C.) TO

MANHOLE SYSTEM.

EXISTING TELEPHONE TERMINAL

CABINET/PULLBOX TO REMAIN.

CONNECT NEW 3" CONDUIT

(TELEPHONE) TO EXISTING TERMINAL

CABINET.

PROVIDE 3"C. FOR NEW TELEPHONE

CABLING

PROVIDE 3"C. FOR NEW TELEPHONE

CABLING

PROVIDE NEW PULLBOX TO

INTERFACE WITH NEW AND EXISTING

CONDUITS. REMOVE EXISTING

PULLBOX AND RECONNECT ALL

EXISTING AND NEW CONDUITS TO

NEW PULLBOX.

EXISTING CONDUITS (2-4"C.) TO

CRAWL SPACE BELOW FIRST FLOOR.

PROVIDE 3"C. FOR NEW DATA

CABLING (NMCI)

C J E F F b l d g b o u n d d w g

B y c o t a j

A

B

C

D

1 2

N A V A L

S T A T I O N

N E W P O R T

T O

B U I L D I N G

N R R C

E N G I N E E R I N G

F I E L D

A C T I V I T Y

N O R T H E A S T

D E P A R T M E N T

O F

T H E

N A V Y

N A V A L

F A C I L I T I E S

E N G I N E E R I N G

C O M M A N D

N62472-03-C-0037

DRAWFORM REVISION FEBRUARY 2001

NAVFAC DRAWING NO.

SHEET OF

CONSTR. CONTR. NO.

STA. PROJ. NO.

SPEC. NO. 04-03-0037

EFD NO.

CODE ID. NO. 80091 SIZE D

SCALE:

L E S T E R

AS NOTED

A

CHIEF ARCH./ ENGR.

N E W P O R T

R I

DESIGN DIRECTOR

BRANCH MANAGER

P E N N S Y L V A N I A

A/E

DESIGN MANAGER

FIRE PROTECTION

DATE

QC

AUGUST 5, 2003

DESIGN

REVIEW

DRAWN

EFD

B

FAY, SPOFFORD & THORNDIKE

91 41

I

FST

E

G N S

RE

EN

APPROVED

ACTIVITY - SATISFACTORY TO

FOR EFA FOR COMMANDER NAVFAC

DATE

APPROVED

BURLINGTON, MA 01803

5 BURLINGTON WOODS

C

SEAL

S Y M

DD

E S C R I P T I O N

D A T E

A P P R

A L T E R A T I O N S R E P A I R S

E L E C T R I C A L

F I R S T

F L O O R

T E L E C O M M U N I C A T I O N S

A N D

F I R E

A L A R M

P L A N

J.COTA

J.COTA

CWPC

CWPC

V.M.GOVONI

E-8

2219867

REFER TO DRAWING E-1 FOR GENERAL NOTES,

LEGEND AND ABBREVIATIONS.

REFER TO DRAWING E-12 FOR TELEPHONE

AND DATA RISER DIAGRAMS.

REFER TO DRAWING E-11 FOR FIRE ALARM

RISER DIAGRAM.

ALL TELEPHONE AND DATA CABLING SHALL BE

RUN CONCEALED ABOVE DROPPED CEILINGS

WHERE POSSIBLE. ALL CABLING RUNNING OVER

EXPOSED BEAMS SHALL BE TIE WRAPPED IN

NEAT WORKMANLIKE MANNER. REFER TO

ARCHITECTURAL DRAWINGS FOR REFLECTED

CEILING PLANS.

PROVIDE (1) 1 1/4"C. STUBBED INTO CEILING

SPACE IN CORRIDOR FOR EVERY (3) DATA

OUTLETS LOCATED IN 2-COMPARTMENT

SURFACE METAL RACEWAY SYSTEM FOR DATA

CABLING.

ALL TELEPHONE AND DATA CABLING RUNNING

VERTICALLY BETWEEN FLOORS SHALL BE

ROUTED VIA VERTICAL WIREWAYS. CORE DRILL

FLOORS (4" CONCRETE SLAB) AS REQUIRED

FOR INSTALLATION OF WIREWAYS. FIELD

COORDINATE EXACT LOCATIONS OF WIREWAYS.

PROVIDE 4'x8' PLYWOOD BACKBOARD ON

NORTH AND SOUTH WALLS OF TELECOM ROOM.

NOTES:

1.

N

CHECK GRAPHIC SCALES BEFORE USING

" = 1'-0" HORIZONTAL8/1

0 8 16 48

2.

3.

4.

5.

6.

7.