REFERENCEInfoBldg345Comms.pdf
PDF 319 KB Posted
- Solicitation number
- N4008521R0078
About this file
This document package includes an electrical drawing and related federal contract opportunity. The electrical drawing depicts the first floor telecommunications and fire alarm plan for Building 345 at Naval Station Newport, and provides notes regarding installation of telephone, data, and fire alarm cabling.
The associated federal contract opportunity is a solicitation for a Design-Build/Design-Bid-Build, Indefinite Delivery/Indefinite Quantity Multiple Award Construction Contract for general construction services at Naval Submarine Base New London in Connecticut and Naval Station Newport in Rhode Island. The solicitation was issued by the Department of the Navy Naval Facilities Engineering Command for an IDIQ MACC with an indefinite quantity of construction projects to be awarded over the life of the contract.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4 1311 14 159876531 10 12
A
C
B
D
E
UV
UV
UV
UV UV UV
UV
PTAC PTAC
PTAC
PTAC
FIN T FIN TFIN T
F I N
T
F I N
T
COMPUTER
CENTER
CORRIDOR
STAIR 2
ST2-1
STAIR 3
ST3-1
STAIR 1
ST1-1
STORAGE
SUPPLY
STORAGE
106A
VTC
SUPR
101A
QUARTER
DECK
VENDING
100A
ELECTRICAL
CLASSROOM
SUPPLY OFFICE
VTC/CONF
DRILL DECK
VEST
109A
24 SF
VEST
110A
29 SF
MEN
176 SF
WOMEN
187 SF
VEST.
56 SF
CG
37 SF
TELECOM
48 SF
FIRST FLOOR PLAN
SCALE: 1/8"=1'-0"
110cd
P
P
75cd
110cd 75cd
75cd
75cd
75cd
75cd
FCP
F
75cd
P
75cd
DN
SCALE: 1/8"=1'-0"
BASEMENT MECHANICAL ROOM
R/F
135°
3-4" CONDUIT SLEEVES
TO 2ND FLOOR FOR DATA
CABLING AND NMCI
SERVICE CABLE. REFER
TO DRAWING E-12 FOR
FURTHER INFORMATION.
4"x4" VERTICAL WIREWAY
FOR TELEPHONE CABLING.
REFER TO DRAWING E-12
FOR FURTHER INFORMATION.
75cd
P
75cd
EXISTING CONDUIT SLEEVE TO CRAWL
SPACE BELOW TO REMAIN FOR NEW
TELEPHONE CABLING.
CORE DRILL AND PROVIDE NEW
CONDUIT SLEEVE TO EXISTING CRAWL
SPACE BELOW FOR INSTALLATION OF
NEW NMCI CABLING.
W W
W
W
SEE NOTE #5
(TYPICAL)
2-4" CONDUIT SLEEVES
ABOVE CEILING FOR
TELEPHONE/DATA CABLING
2-4" CONDUIT SLEEVES
ABOVE CEILING FOR
TELEPHONE/DATA CABLING
P D
NEW LOCATION OF EXISTING FIRE ALARM
MASTER BOX AND BEACON. PROVIDE NEW
FIRE ALARM CABLING. EXTEND EXISTING
CONDUIT TO NEW LOCATION AS REQUIRED.
CONNECT EXISTING FIRE ALARM BEACON TO
EXTERIOR LIGHTING CIRCUIT (CONSTANT ON,
CONNECT AHEAD OF TIMECLOCK CONTROL)
P
P
SEE NOTE #7
PB
PB
PROVIDE NEW PULLBOX TO
INTERFACE WITH EXISTING CONDUITS
(4-4"C.) TO MANHOLE SYSTEM.
REMOVE EXISTING PULLBOX AND
RECONNECT ALL EXISTING AND NEW
CONDUITS TO NEW PULLBOX.
P B
EXISTING CONDUITS (4-4"C.) TO
MANHOLE SYSTEM.
EXISTING TELEPHONE TERMINAL
CABINET/PULLBOX TO REMAIN.
CONNECT NEW 3" CONDUIT
(TELEPHONE) TO EXISTING TERMINAL
CABINET.
PROVIDE 3"C. FOR NEW TELEPHONE
CABLING
PROVIDE 3"C. FOR NEW TELEPHONE
CABLING
PROVIDE NEW PULLBOX TO
INTERFACE WITH NEW AND EXISTING
CONDUITS. REMOVE EXISTING
PULLBOX AND RECONNECT ALL
EXISTING AND NEW CONDUITS TO
NEW PULLBOX.
EXISTING CONDUITS (2-4"C.) TO
CRAWL SPACE BELOW FIRST FLOOR.
PROVIDE 3"C. FOR NEW DATA
CABLING (NMCI)
C J E F F b l d g b o u n d d w g
B y c o t a j
A
B
C
D
1 2
N A V A L
S T A T I O N
N E W P O R T
T O
B U I L D I N G
N R R C
E N G I N E E R I N G
F I E L D
A C T I V I T Y
N O R T H E A S T
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C I L I T I E S
E N G I N E E R I N G
C O M M A N D
N62472-03-C-0037
DRAWFORM REVISION FEBRUARY 2001
NAVFAC DRAWING NO.
SHEET OF
CONSTR. CONTR. NO.
STA. PROJ. NO.
SPEC. NO. 04-03-0037
EFD NO.
CODE ID. NO. 80091 SIZE D
SCALE:
L E S T E R
AS NOTED
A
CHIEF ARCH./ ENGR.
N E W P O R T
R I
DESIGN DIRECTOR
BRANCH MANAGER
P E N N S Y L V A N I A
A/E
DESIGN MANAGER
FIRE PROTECTION
DATE
QC
AUGUST 5, 2003
DESIGN
REVIEW
DRAWN
EFD
B
FAY, SPOFFORD & THORNDIKE
91 41
I
FST
E
G N S
RE
EN
APPROVED
ACTIVITY - SATISFACTORY TO
FOR EFA FOR COMMANDER NAVFAC
DATE
APPROVED
BURLINGTON, MA 01803
5 BURLINGTON WOODS
C
SEAL
S Y M
DD
E S C R I P T I O N
D A T E
A P P R
A L T E R A T I O N S R E P A I R S
E L E C T R I C A L
F I R S T
F L O O R
T E L E C O M M U N I C A T I O N S
A N D
F I R E
A L A R M
P L A N
J.COTA
J.COTA
CWPC
CWPC
V.M.GOVONI
E-8
2219867
REFER TO DRAWING E-1 FOR GENERAL NOTES,
LEGEND AND ABBREVIATIONS.
REFER TO DRAWING E-12 FOR TELEPHONE
AND DATA RISER DIAGRAMS.
REFER TO DRAWING E-11 FOR FIRE ALARM
RISER DIAGRAM.
ALL TELEPHONE AND DATA CABLING SHALL BE
RUN CONCEALED ABOVE DROPPED CEILINGS
WHERE POSSIBLE. ALL CABLING RUNNING OVER
EXPOSED BEAMS SHALL BE TIE WRAPPED IN
NEAT WORKMANLIKE MANNER. REFER TO
ARCHITECTURAL DRAWINGS FOR REFLECTED
CEILING PLANS.
PROVIDE (1) 1 1/4"C. STUBBED INTO CEILING
SPACE IN CORRIDOR FOR EVERY (3) DATA
OUTLETS LOCATED IN 2-COMPARTMENT
SURFACE METAL RACEWAY SYSTEM FOR DATA
CABLING.
ALL TELEPHONE AND DATA CABLING RUNNING
VERTICALLY BETWEEN FLOORS SHALL BE
ROUTED VIA VERTICAL WIREWAYS. CORE DRILL
FLOORS (4" CONCRETE SLAB) AS REQUIRED
FOR INSTALLATION OF WIREWAYS. FIELD
COORDINATE EXACT LOCATIONS OF WIREWAYS.
PROVIDE 4'x8' PLYWOOD BACKBOARD ON
NORTH AND SOUTH WALLS OF TELECOM ROOM.
NOTES:
1.
N
CHECK GRAPHIC SCALES BEFORE USING
" = 1'-0" HORIZONTAL8/1
0 8 16 48
2.
3.
4.
5.
6.