This solicitation is for repair and renovation services at Building 488, a 109,442 square foot permanent party enlisted housing facility at Naval Submarine Base New London in Connecticut. Work includes whole building repairs, constructing a new sidewalk, site work, and upgrades to fire protection, interior finishes, electrical, elevators, HVAC, plumbing and exterior enclosure. The opportunity was issued by the Department of the Navy Naval Facilities Engineering Command. Responses were due by January 28, 2020, with award dates to be determined.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
SYMBOLS LEGEND
E
R
P
B-#
FE
BUILDING CODE SUMMARY
BUILDING FEATURE REQUIRED/ALLOWED PROVIDED REFERENCE
OCCUPANCY CLASSIFICATION
RESIDENTIAL GROUP R-2 RESIDENTIAL GROUP R-2
IBC - CHAPTER 3STORAGE GROUP S-2 STORAGE GROUP S-2
BUSINESS GROUP B BUSINESS GROUP B
CONSTRUCTION TYPE II-B II-B IBC - TABLE 601
ALLOWABLE HEIGHT 5 STORIES 5 STORIES IBC - TABLE 504.4
ALLOWABLE AREA 48,000 SF 26,500 SF IBC - TABLE 506.2
EXTERIOR EXPOSURE
PROTECTION
BUILDING SEPARATION DISTANCE
IS GREATER THAN 30 FT
NO FIRE RESISTANCE RATING
REQUIRED FOR EXTERIOR
WALLS
IBC - TABLE 602
SEPARATION OF
OCCUPANCIES
NONSEPARATED NONSEPARATED IBC - SECTION 508.2.4
INCIDENTAL USES
LAUNDRY ROOMS OVER 100
SQUARE FEET - 1-HOUR OR
AUTOMATIC SPRINKLERS
AUTOMATIC SPRINKLERS IBC - SECTION 509
FIRE RESISTANCE RATING
FOR BUILDING ELEMENTS
(TYPE II B CONSTRUCTION)
PRIMARY STRUCTURAL FRAME
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
EXTERIOR NON-BEARING WALLS
INTERIOR NON-BEARING WALLS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
0-HOUR
0-HOUR
0-HOUR
0-HOUR
0-HOUR
0-HOUR
0-HOUR
IBC - TABLE 601
ROOF DECK ASSEMBLY CLASS C
CLASS A RATED IN
ACCORDANCE WITH ASTM
E108, FM 4470, OR UL 790 AND
BE LISTED AS CLASS I ROOF
DECK CONSTRUCTION IN FM
APP GUIDE
UFC 3-600-01, SECTION
15-2.1.1
SEISMIC DESIGN CATEGORY CATEGORY B IBC/ASCE-07
TD
CP
MAXIMUM TRAVEL DISTANCE
MAXIMUM COMMON PATH OF TRAVEL
EXIT
DE
DEAD END CORRIDOR
EXIT NUMBER
REQUIRED EGRESS (PEOPLE)
PROVIDED EGRESS (PEOPLE)
LIFE SAFETY CODE SUMMARY - BACHELOR QUARTERS
BUILDING FEATURE REQUIRED/ALLOWED PROVIDED REFERENCE
OCCUPANCY CLASSIFICATION
EXISTING HOTEL AND
DORMITORY
EXISTING DORMITORY NFPA 101, CHAPTER 29
EXISTING BUSINESS EXISTING BUSINESS NFPA 101, CHAPTER 39
INCIDENTAL STORAGE INCIDENTAL STORAGE
NFPA 101, SECTION 6.1.14.1.3
AND 42.1.2.2.
NUMBER OF EXITS 2 MINIMUM 2 MINIMUM
NFPA 101 - 29.2.4, 39.2.4
EXIT CAPACITY
SEE EXIT CAPACITY
CALCULATIONS
SEE EXIT CAPACITY
CALCULATIONS
NFPA 101 - CHAPTER 7
REMOTENESS OF EXITS
ONE-THIRD THE DISTANCE OF
BUILDING OR AREA DIAGONAL
MINIMUM ONE- THIRD THE
DISTANCE OF
BUILDING/AREA DIAGONAL
NFPA 101 - 29.2.5, 39.2.5
TRAVEL DISTANCE
RESIDENTIAL 325 FEET MAXIMUM VARIES, LESS THAN 325 FEET NFPA 101 - 29.2.6
BUSINESS 300 FEET MAXIMUM VARIES, LESS THAN 300 FEET NFPA 101 - 39.2.6
STORAGE / MEP 400 FEET MAXIMUM VARIES, LESS THAN 400 FEET NFPA 101 - 42.2.6
COMMON PATH OF TRAVEL
RESIDENTIAL
35 FEET. MAXIMUM GUEST RM
& 50 FEET MAXIMUM
ELSEWHERE
VARIES, LESS THAN 35/50
FEET
NFPA 101 - 29.2.5.3
NFPA 101 - 29.2.5.4
BUSINESS 100 FEET MAXIMUM VARIES, LESS THAN 100 FEET NFPA 101 - 39.2.5
STORAGE / MEP 100 FEET MAXIMUM VARIES, LESS THAN 100 FEET NFPA 101 - 42.2.5
DEAD END CORRIDORS
RESIDENTIAL 50 FEET MAXIMUM VARIES, LESS THAN 50 FEET NFPA 101 - 29.2.5.5
BUSINESS 50 FEET MAXIMUM VARIES, LESS THAN 50 FEET NFPA 101 - 39.2.5.5
STORAGE / MEP 100 FEET MAXIMUM VARIES, LESS THAN 100 FEET
EXIT DISCHARGE
ACCESS TO EXTERIOR/PUBLIC
WAY
ACCESS TO
EXTERIOR/PUBLIC WAY
NFPA 101 - 7.7
EXIT STAIRS FIRE RATING 1-HOUR 1-HOUR NFPA 101 - 7.1.3.2
VERTICAL OPENINGS FIRE RATING
EXISTING 1/2-HOUR
NFPA 101 - 8.6.5NEW 3-STORIES OR LESS 1-HOUR
NEW 4-STORIES OR MORE 2-HOUR
CORRIDOR SEPARATION NR NR NFPA 101 - 29.3.6.1.3
INCIDENTAL OCCUPANCY SEPARATION NR NR NFPA 101 - 8.7.1.2
INTERIOR FINISH
EXIT ENCLOSURES CLASS A OR B AS REQUIRED
NFPA 101 - 29.3.3.2LOBBIES AND CORRIDORS CLASS A OR B AS REQUIRED
OTHER SPACES CLASS A, B, OR C AS REQUIRED
SPECIAL LOCKING ARRANGEMENTS N/A NONE
FIRE ALARM SYSTEM YES YES NFPA 101 - 29.3.4
MASS NOTIFICATION SYSTEM YES NO UFC 4-010-01
AUTOMATIC SPRINKLER SYSTEM YES YES UFC 3-600-01, 6-22.1
FIRE EXTINGUISHERS NO SEE GENERAL NOTES UFC 3-600-01, 9-17.1
EMERGENCY LIGHTING
IN ALL MEANS OF EGRESS AND
AT EXIT DISCHARGE
YES NFPA 101 - 7.9
EXIT SIGNAGE YES YES NFPA 101 - 7.10
EXIT CAPACITY
EXIT
COMPONENT
CLEAR
WIDTH
EXIT
CAPACITY
FACTOR
(NFPA 101 -
7.3.3.1)
CAPACITY
STAIR 1 37" 0.3"/PERSON 123 PERSONS
STAIR 2 37" 0.3"/PERSON 123 PERSONS
STAIR 3 37" 0.3"/PERSON 123 PERSONS
STAIR 4 37" 0.3"/PERSON 123 PERSONS
STAIR 5 37" 0.3"/PERSON 123 PERSONS
STAIR 6 37" 0.3"/PERSON 123 PERSONS
TOTAL 738 PERSONS
EXTERIOR
DOOR 7
(CORRIDOR
N-133)
36" 0.2"/PERSON 180 PERSONS
EXTERIOR
DOOR 8
(MECHANICAL
ROOM N-101.1)
46" 0.2"/PERSON 230 PERSONS
EXTERIOR
DOOR 9
(MECHANICAL
ROOM N-101)
39" 0.2"/PERSON 195 PERSONS
EXTERIOR
DOOR 10 (
ENTRY)
34" x 2 0.2"/PERSON 340 PERSONS
EXTERIOR
DOOR 11 (
VESTIBULE
C-123)
34" x 2 0.2"/PERSON 340 PERSONS
EXTERIOR
DOOR 12 (
VESTIBULE
C-123)
34" x 2 0.2"/PERSON 340 PERSONS
ANTICIPATED OCCUPANT LOAD
ROOM/SPACE FLOOR AREA
OCCUPANT LOAD
FACTOR (SF/PERSON)
OCCUPANT LOAD
BASEMENT
MECHANICAL ROOM 966 SQ. FT. 500 2
TOTAL: 2
FIRST FLOOR
BUILDING SUPPORT 2,090 SQ. FT. 500 5
BERTHING ROOMS - NORTH 5,891 SQ.FT. 50 118
BERTHING ROOMS - SOUTH 11,342 SQ.FT. 50 227
BUSINESS 517 SQ.FT. 100 6
LOUNGE 389 SQ.FT. 15 26
TOTAL: 382
SECOND FLOOR
BERTHING ROOMS - NORTH 10,303 SQ.FT. 50 206
BERTHING ROOMS - SOUTH 11,308 SQ.FT. 50 227
OFFICE 318 SQ.FT. 100 4
GAME ROOM 598 SQ.FT. 15 38
TV ROOM 348 SQ.FT. 15 24
TOTAL 499
THIRD FLOOR
BERTHING ROOMS - NORTH 10,289 SQ.FT. 50 206
BERTHING ROOMS - SOUTH 11,330 SQ.FT. 50 227
LOUNGE 315 SQ.FT. 15 21
TOTAL 454
FOURTH FLOOR
BERTHING ROOMS - NORTH 11,340 SQ.FT. 50 227
BERTHING ROOMS - SOUTH 10,986 SQ.FT. 50 220
LOUNGE 315 SQ.FT. 15 21
BUILDING SUPPORT 243 SQ.FT. 500 1
TOTAL 469
FIFTH FLOOR
BERTHING ROOMS - NORTH 11,330 SQ.FT. 50 221
BUILDING SUPPORT 241 SQ.FT. 500 1
LOUNGE 315 SQ.FT. 15 21
TOTAL 243
NORTH ROOF
ELEVATOR MACHINE ROOM 385 SQ.FT. 500 1
TOTAL 1
SOUTH ROOF
ELEVATOR MACHINE ROOM 385 SQ.FT. 500 1
TOTAL 1
APPLICABLE CODES AND STANDARDS
REFERENCE NAME EDITION
UFC 1-200-01 GENERAL BUILDING REQUIREMENTS
20-JUN-16 CHANGE 2,
01 NOV 2018
UFC 3-600-01 DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES
8-AUG-16 CHANGE 3,
10 MAY 2019
UFC 3-600-02 OPERATIONS AND MAINTENANCE: INSPECTION,TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS 8-SEP-10
UFC 4-021-01 DESIGN AND O&M: MASS NOTIFICATION SYSTEMS
9-APR-08 CHANGE 1,
JANUARY 2010
IBC ICC INTERNATIONAL BUILDING CODE 2015
IEBC ICC INTERNATIONAL EXISTING BUILDING CODE 2015
NFPA 10 STANDARD FOR THE PORTABLE FIRE EXTINGUISHERS 2019
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2019
NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPES AND HOSE SYSTEMS 2019
NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION 2019
NFPA 70 NATIONAL ELECTRIC CODE 2017
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2019
NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES 2019
NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION SYSTEMS 2018
NFPA 101 LIFE SAFETY CODE 2018
NFPA 241 STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS 2019
ABA THE ARCHITECTURAL BARRIERS ACT 2010
IECC ENERGY CONSERVATION CODE OF CONNECTICUT 2018
UNIFIED FACILITIES CRITERIA - CURRENT EDITIONS WITH APPLICABLE CODES/STANDARDS
REFERENCED THEREIN (REFER ALSO TO SPECIFIC DISCIPLINE DRAWINGS AND SPECIFICATIONS)
RESIST THE PASSAGE OF SMOKE
1/2 HOUR FIRE RESISTANCE RATED
1 HOUR FIRE RESISTANCE RATED
THE LIFE SAFETY SCOPE OF WORK INCLUDES THE
FOLLOWING, AS SHOWN ON THE DRAWINGS:
PROVIDING SMOKE TIGHT SEALS
PROVIDING FIRESTOPPING SYSTEMS
REMOVING EXISTING FIRE EXTINGUISHERS AND
CABINETS FROM THE THROUGHOUT THE BUILDING.
REUTILIZE THE SALVAGED FIRE EXTINGUISHERS
AND CABINETS WITHIN THE MECHANICAL ROOMS
AND THE ELEVATOR MACHINE ROOMS.
MODIFYING AND OR REPLACING HANDRAILS AND
GUARDRAILS IN THE EXIT STAIRWELLS AND ALONG
THE CORRIDOR WINDOWS.
PROVIDING PERMANENT EXTERIOR STAIRS AND
HANDRAILS FOR THE MECHANICAL ROOM.
EXIT
SIGN
FIRE
EXTINGUISHER
N = NEW E = EXISTING R = RELOCATE D = DELETE
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
:0 :2
P M
P R
O
JE
C T
R M
-1
0, R E
P A
IR
F
A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-001
N40085-20-R-0034
L
IF
E
S A F E T Y
N O T E S
A N D
S Y M B O L S
L E G E N D
L S
12806943
PSM PSM CMA
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
2 0
A1
CODE COMPLIANCE SITE PLAN
W (R ) W(R)
W(R)
W(R)
W( R)
W( R)
W( R)
W( R)
W(R)
W (R)
W (R)
SB
CC
BUILDING #488
FIRE HYDRANT
FIRE HYDRANT
FIRE DEPT CONNECTION
8" FIRE SERVICE
POST INDICATOR VALVE
FIRE PUMP ROOM
12" WATER MAIN
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
:5 :0
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-002
N40085-20-R-0034
L
IF
E
S A F E T Y
C O D E
C O M P L
IA
N C E
S
IT
E
P L A N
L S
12806944
PSM PSM CMA
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24
FFEEDDCCBBAA
M
L
B
C
D E
F
G
H
K
J
CP = 60 FT
STAIR
EXIT #1
R 2
P 10
STAIR #3
R 1
P 123
N
N
OCCUPANCY CLASSIFICATIONS:
RESIDENTIAL
BUSINESS
BUSINESS (LESS THEN 50 PEOPLE)
BUILDING SUPPORT
NOT OCCUPIED
NORTH
A
C
B D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
:0 :3
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-100
N40085-20-R-0034
L
IF
E
S A F E T Y
O V E R A L L
G R O U N D
F L O O R
P L A N
L S
12806945
PSM PSM CMA
SCALE: 1 : 150
LIFE SAFETY GROUND FLOOR OVERALL PLAN
A1
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
14 15 16 17 18
FFEEDDCCBBAA
M
L
F
G
H
K
J
9 10 11 12 13 14BBAA
B
C
D
E
F
G
HJ
N
LIFE SAFETY DRAWING KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
A
B
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :0
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-100A&B
N40085-20-R-0034
L
IF
E
S A F E T Y
G R O U N D
F L O O R
P L A N
P A R T
A
B
L S A B
12806946
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY GROUND FLOOR PLAN - PART A
A1
SCALE: 1/8" = 1'-0"
LIFE SAFETY GROUND FLOOR PLAN - PART B
A3
PROVIDE SIGN FOR MANUAL OPERATION OF THE OVERHEAD DOOR (SEE ARCHITECTUAL DRAWINGS)
INSTALL THERMAL BARRIER ON THE CEILING TO SEPERATE THE SPRAY POLYURETHANE FOAM
INSULATION FROM THE INTERIOR OF THE BUILDING. THE THERMAL BARRIER SHALL BE
CONSTRUCTED OF 1/2 INCH GYPSUM WALLBOARD. (SEE ARCHITECTUAL DRAWINGS)
1 PROVIDE EMERGENCY LIGHTING AND ILLUMINATED EXIT SIGN (SEE ELECTRICAL DRAWINGS)
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
12 13 14 15 16 17 18
FFEEDDCCBBAA
B
C
D
E
F
G
HJ
STAIR
N
LIFE SAFETY DRAWING KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :0
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-100D
N40085-20-R-0034
L
IF
E
S A F E T Y
G R O U N D
F L O O R
P L A N
P A R T
D
L S D
12806947
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY GROUND FLOOR PLAN - PART B
A1
1 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
WD
D
D D
D D
D D
W W
W W
W W
W
D D
D D
D D
D D
W W
W W
W W
W W
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24
FFEEDDCCBBAA
M
L
B
C
D E
F
G
H
K
J
TD = 96 FT TD = 116 FT
CP = 60 FT
TD = 66 FT TD = 86 FT TD = 128 FT TD = 96 FT
BERTHING
UNIT
N-119
BERTHING
UNIT
N-117
BERTHING
UNIT
N-115
BERTHING
UNIT
N-113
LAUNDRY
ROOM
N-111
FIRE PUMP
N-109
CORRIDOR
N-133
BERTHING
UNIT
N-120
BERTHING
UNIT
N-118
BERTHING
UNIT
N-116
BERTHING
UNIT
N-114
BERTHING
UNIT
N-112
BERTHING
UNIT
N-110
STAIR
ELEVATOR
LOBBY
N-134
ELEVATOR
P-1
UTILITY
N-135
VESTIBULE
C-123
LOUNGE
C-108
STAIR
SWITCH
GEAR ROOM
N-101
UTILITY
N-108
MECHANICAL
ROOM
N-102
MECHANICAL
ROOM
N-101.1
STAIR
C-108B
RECEPTION
DESK
C-108A
VENDING
C-115
JAN. CLO
C-117
CORRIDOR
C-116
W.C.
C-114
VESTIBULE
C-119
OFFICE
C-120
CORRIDOR
C-122
STAIR
BERTHING
UNIT
S-101
BERTHING
UNIT
S-103
BERTHING
UNIT
S-105
BERTHING
UNIT
S-107
STAIR
VESTIBULE
C-124
ELEVATOR
LOBBY
S-134
ELEVATOR
P-2
UTILITY
S-135
BERTHING
UNIT
S-102
BERTHING
UNIT
S-104
LAUNDRY
ROOM
S-106
BAG
STORAGE
S-108
CORRIDOR
S-137
BERTHING
UNIT
S-110
BERTHING
UNIT
S-112
BERTHING
UNIT
S-114
BERTHING
UNIT
S-116
BERTHING
UNIT
S-118
BERTHING
UNIT
S-120
BERTHING
UNIT
S-122
BERTHING
UNIT
S-124
BERTHING
UNIT
S-126
BERTHING
UNIT
S-128
CORRIDOR
S-133
STAIR
BERTHING
UNIT
S-127
BERTHING
UNIT
S-125
BERTHING
UNIT
S-123
BERTHING
UNIT
S-121
BERTHING
UNIT
S-119
BERTHING
UNIT
S-117
BERTHING
UNIT
S-115
BERTHING
UNIT
S-113
CP = 20 FT
EXTERIOR #7
R 60
P 180
EXTERIOR #8
R 2
P
EXTERIOR #9
R 1
P
EXTERIOR #11
R 75
P
STAIR #4
R 0
P
STAIR #1
R 76
P
EXTERIOR #12
R 76
P
STAIR #3
R 76
P
EXTERIOR #10
R 16
P
N
N
EE
E
E
E
E
E
E
EE
E
EE E
OCCUPANCY CLASSIFICATIONS:
RESIDENTIAL
BUSINESS
BUSINESS (LESS THEN 50 PEOPLE)
BUILDING SUPPORT
NOT OCCUPIED
NORTH
A
C
B D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
:0 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-101
N40085-20-R-0034
L
IF
E
S A F E T Y
O V E R A L L
F
IR
S T
F L O O R
P L A N
L S
12806948
PSM PSM CMA
SCALE: 1 : 150
LIFE SAFETY FIRST FLOOR OVERALL PLAN
A1
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
WD
D D
D D
D D
W W
W W
W W
W
14 15 16 17 18
FFEEDDCCBBAA
M
L
F
G
H
K
J
LOUNGE
C-108
STAIR
SWITCH
GEAR ROOM
N-101
UTILITY
N-108
MECHANICAL
ROOM
N-102
MECHANICAL
ROOM
N-101.1
STAIR
C-108B
RECEPTION
DESK
C-108A
VENDING
C-115
JAN. CLO
C-117
CORRIDOR
C-116
W.C.
C-114
N
E
9 10 11 12 13 14BBAA
B
C
D
E
F
G
HJ
15 16
CORRIDOR
C-122
STAIR
BERTHING
UNIT
S-101
BERTHING
UNIT
S-103
BERTHING
UNIT
S-105
BERTHING
UNIT
S-107
STAIR
VESTIBULE
C-124
ELEVATOR
LOBBY
S-134
ELEVATOR
P-2 UTILITY
S-135
BERTHING
UNIT
S-102
BERTHING
UNIT
S-104
LAUNDRY
ROOM
S-106
BAG
STORAGE
S-108
CORRIDOR
S-137
FE
FE
N
D
D
D
E
EE
E
E E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
A
B
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :2
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-101A&B
N40085-20-R-0034
L
IF
E
S A F E T Y
F
IR
S T
F L O O R
P L A N
P A R T
A
B
L S A B
12806949
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY FIRST FLOOR PLAN - PART A
A1
SCALE: 1/8" = 1'-0"
LIFE SAFETY FIRST FLOOR PLAN - PART B
A3
1 PROVIDE PERMANENT FIXED STAIR ASSEMBLY WITH HANDRAILS (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
TWELVE (12) FEET OF FLUTED DECKING (SEE DETAIL LS-200)
FOUR (4) 1" TO 6" METAL PIPES (SEE DETAIL LS-200)
TWO (2) 1/4" TO 3" METAL CONDUITS AND ONE (1) 1" TO 6" METAL PIPE (SEE DETAIL LS-201)
3 PROVIDE HANDRAIL FOR THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
TWO (2) 1" TO 6" METAL PIPES AND EIGHT FEET OF FLUTTED DECKING (SEE DETAIL LS-201)
ONE (1) METAL CABLE TRAY AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 4" TO 8" METAL DUCTS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1/4" TO 3" METAL CONDUITS AND TWO (2) 1" TO 6" METAL PIPE (SEE DETAIL LS-201)
19 FOUR (4) 1" TO 6" METAL PIPES AND REPLACE TWO (2) DAMAGED BLOCKS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
D D
D D
D D
W W
W W
W W
W W
3 4 5 6 7 8 9 10 11 12 13 14 15 CCBBAA
M
L
G
H
K
J
141313
BERTHING
UNIT
N-119
BERTHING
UNIT
N-117
BERTHING
UNIT
N-115
BERTHING
UNIT
N-113
LAUNDRY
ROOM
N-111
FIRE PUMP
N-109
CORRIDOR
N-133
BERTHING
UNIT
N-120
BERTHING
UNIT
N-118
BERTHING
UNIT
N-116
BERTHING
UNIT
N-114
BERTHING
UNIT
N-112
BERTHING
UNIT
N-110
STAIR
ELEVATOR
LOBBY
N-134
ELEVATOR
P-1
UTILITY
N-135
VESTIBULE
C-123
FE
FE
FE
D
D
D
EE
E
E
E
E
FIRE PROTECTION DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTHC
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :2
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-101C
N40085-20-R-0034
L
IF
E
S A F E T Y
F
IR
S T
F L O O R
P L A N
P A R T
C
L S C
12806950
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY FIRST FLOOR PLAN - PART C
A1
1 PROVIDE GUARDS ALONG EXISTING WINDOW (SEE ARCHITECTUAL DRAWINGS)
TWO (2) WIRE BUNDLES AND TWO (2) 1" TO 6" METAL PIPE (SEE DETAIL LS-201)
TWO (2) WIRE BUNDLES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
FOUR (4) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
FOUR (4) 1" TO 6" METAL PIPES AND REPLACE TWO (2) DAMAGED BLOCKS (SEE DETAIL LS-201)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 4" TO 8" METAL DUCTS (SEE DETAIL LS-200)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
W W
W W
W W
W W
12 13 14 15 16 17 18
19 20 21 22 23 24
FFEEDDCCBBAA
B
C
D
E
F
G
HJ
1010101011
VESTIBULE
C-119
OFFICE
C-120
BERTHING
UNIT
S-110
BERTHING
UNIT
S-112
BERTHING
UNIT
S-114
BERTHING
UNIT
S-116
BERTHING
UNIT
S-118
BERTHING
UNIT
S-120
BERTHING
UNIT
S-122
BERTHING
UNIT
S-124
BERTHING
UNIT
S-126
BERTHING
UNIT
S-128
CORRIDOR
S-133
STAIR
BERTHING
UNIT
S-127
BERTHING
UNIT
S-125
BERTHING
UNIT
S-123
BERTHING
UNIT
S-121
BERTHING
UNIT
S-119
BERTHING
UNIT
S-117
BERTHING
UNIT
S-115
BERTHING
UNIT
S-113
FE
DD
FE
DD
E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :3
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-101D
N40085-20-R-0034
L
IF
E
S A F E T Y
F
IR
S T
F L O O R
P L A N
P A R T
D
L S D
12806951
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY FIRST FLOOR PLAN - PART D
A1
1 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
FOUR (4) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
M
L
B
C
D E
F
G
H
K
J
TD = 66 FT TD = 86 FT TD = 128 FT TD = 96 FT
TD = 118 FT TD = 104 FT TD = 66 FT
STAIR
BERTHING
UNIT
N-227
BERTHING
UNIT
N-225
BERTHING
UNIT
N-223
BERTHING
UNIT
N-221
BERTHING
UNIT
N-219
BERTHING
UNIT
N-217
BERTHING
UNIT
N-215
BERTHING
UNIT
N-213
BERTHING
UNIT
N-211
BERTHING
UNIT
N-209
ELEVATOR
LOBBY
N-234
ELEVATOR
P-1
UTILITY
N-235
STAIR
BERTHING
UNIT
N-210
BERTHING
UNIT
N-212
BERTHING
UNIT
N-214
BERTHING
UNIT
N-216
BERTHING
UNIT
N-218
BERTHING
UNIT
N-220
CORRIDOR
N-233
BERTHING
UNIT
N-222
BERTHING
UNIT
N-224
BERTHING
UNIT
N-226
BERTHING
UNIT
N-228
CORRIDOR
N-237
STAIR
C-108B
BERTHING
UNIT
N-207
BERTHING
UNIT
N-205
STAIR
BERTHING
UNIT
N-206
BERTHING
UNIT
N-208
LOUNGE
C-203
LOUNGE
C-204
STAIR
BERTHING
UNIT
S-201
BERTHING
UNIT
S-203
BERTHING
UNIT
S-205
BERTHING
UNIT
S-207
STAIR
BERTHING
UNIT
S-209
BERTHING
UNIT
S-211
BERTHING
UNIT
S-213
BERTHING
UNIT
S-215
BERTHING
UNIT
S-217
BERTHING
UNIT
S-219
BERTHING
UNIT
S-221
BERTHING
UNIT
S-223
BERTHING
UNIT
S-225
BERTHING
UNIT
S-227
STAIR
BERTHING
UNIT
S-228
BERTHING
UNIT
S-226
BERTHING
UNIT
S-224
BERTHING
UNIT
S-222
BERTHING
UNIT
S-220
BERTHING
UNIT
S-218
BERTHING
UNIT
S-216
BERTHING
UNIT
S-214
BERTHING
UNIT
S-212
STUDY
S-210
ELEVATOR
P-2 UTILITY
S-235
ELEVATOR
LOBBY
S-234
BERTHING
UNIT
S-202
BERTHING
UNIT
S-204
BERTHING
UNIT
S-206
BERTHING
UNIT
S-208
STAIR #5
R 99
P
STAIR #4
R 69
P 123
STAIR #1
R 77
P
STAIR #2
R 108
P
STAIR #3
R 77
P
STAIR #6
R 69
P
R
N
E E E
E
E
E
E
E
E
OCCUPANCY CLASSIFICATIONS:
RESIDENTIAL
BUSINESS
BUSINESS (LESS THEN 50 PEOPLE)
BUILDING SUPPORT
NOT OCCUPIED
NORTH
A
C
B D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
:0 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-102
N40085-20-R-0034
L
IF
E
S A F E T Y
O V E R A L L
S E C O N D
F L O O R
P L A N
L S
12806952
PSM PSM CMA
SCALE: 1 : 150
LIFE SAFETY SECOND FLOOR OVERALL PLAN
A1
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
M
L
F
G
H
K
J
CORRIDOR
N-237
STAIR
C-108B
BERTHING
UNIT
N-207
BERTHING
UNIT
N-205
STAIR
BERTHING
UNIT
N-206
BERTHING
UNIT
N-208
LOUNGE
C-203
FE
D
E
9 10 11 12 13 14BBAA
B
C
D
E
F
G
HJ
12 12
STAIR
BERTHING
UNIT
S-201
BERTHING
UNIT
S-203
BERTHING
UNIT
S-205
BERTHING
UNIT
S-207
STAIR
ELEVATOR
P-2 UTILITY
S-235
ELEVATOR
LOBBY
S-234
BERTHING
UNIT
S-202
BERTHING
UNIT
S-204
BERTHING
UNIT
S-206
BERTHING
UNIT
S-208
FE
R
FE
DD
E
E
E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
A
B
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-102A&B
N40085-20-R-0034
L
IF
E
S A F E T Y
S E C O N D
F L O O R
P L A N
P A R T
A
B
L S A B
12806953
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY SECOND FLOOR PLAN - PART A
A1
SCALE: 1/8" = 1'-0"
LIFE SAFETY SECOND FLOOR PLAN - PART B
A3
1 PROVIDE GUARDS ALONG EXISTING WINDOWS (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPE AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPE AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
FOUR (4) WIRE BUNDLES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
FOUR (4) 1" TO 6" METAL PIPES AND REPLACE TWO (2) DAMAGED BLOCKS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
3 4 5 6 7 8 9 10 11 12 13 14 15 CCBBAA
M
L
G
H
K
J
10 10 10 10 10
STAIR
BERTHING
UNIT
N-227
BERTHING
UNIT
N-225
BERTHING
UNIT
N-223
BERTHING
UNIT
N-221
BERTHING
UNIT
N-219
BERTHING
UNIT
N-217
BERTHING
UNIT
N-215
BERTHING
UNIT
N-213
BERTHING
UNIT
N-211
BERTHING
UNIT
N-209
ELEVATOR
LOBBY
N-234
ELEVATOR
P-1
UTILITY
N-235
STAIR
BERTHING
UNIT
N-210
BERTHING
UNIT
N-212
BERTHING
UNIT
N-214
BERTHING
UNIT
N-216
BERTHING
UNIT
N-218
BERTHING
UNIT
N-220
CORRIDOR
N-233
BERTHING
UNIT
N-222
BERTHING
UNIT
N-224
BERTHING
UNIT
N-226
BERTHING
UNIT
N-228
FE FE
FE
N
D D
D
E E
E
E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTHC
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-102C
N40085-20-R-0034
L
IF
E
S A F E T Y
S E C O N D
F L O O R
P L A N
P A R T
C
L S C
12806954
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY SECOND FLOOR PLAN - PART C
A1
1 PROVIDE GUARDS ALONG THE EXISTING WINDOW (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) WIRE BUNDLES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
FOUR (4) 1" TO 6" METAL PIPES AND REPLACE TWO (2) DAMAGED BLOCKS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
B
C
D
E
F
G
HJ
1010101010 11
LOUNGE
C-204
BERTHING
UNIT
S-209
BERTHING
UNIT
S-211
BERTHING
UNIT
S-213
BERTHING
UNIT
S-215
BERTHING
UNIT
S-217
BERTHING
UNIT
S-219
BERTHING
UNIT
S-221
BERTHING
UNIT
S-223
BERTHING
UNIT
S-225
BERTHING
UNIT
S-227
STAIR
BERTHING
UNIT
S-228
BERTHING
UNIT
S-226
BERTHING
UNIT
S-224
BERTHING
UNIT
S-222
BERTHING
UNIT
S-220
BERTHING
UNIT
S-218
BERTHING
UNIT
S-216
BERTHING
UNIT
S-214
BERTHING
UNIT
S-212
STUDY
S-210
FE
FEFE
DD DD
E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :5
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-102D
N40085-20-R-0034
L
IF
E
S A F E T Y
S E C O N D
F L O O R
P L A N
P A R T
D
L S D
12806955
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY SECOND FLOOR PLAN - PART D
A1
1 PROVIDE GUARDS ALONG THE EXISTING WINDOW (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
FOUR (4) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
M
L
B
C
D E
F
G
H
K
J
TD = 66 FT TD = 86 FT TD = 128 FT TD = 96 FT
TD = 118 FT TD = 104 FT TD = 66 FT TD = 76 FT
STAIR
BERTHING
UNIT
N-327
BERTHING
UNIT
N-325
BERTHING
UNIT
N-323
BERTHING
UNIT
N-321
BERTHING
UNIT
N-319
BERTHING
UNIT
N-317
BERTHING
UNIT
N-315
BERTHING
UNIT
N-313
BERTHING
UNIT
N-311
BERTHING
UNIT
N-309
ELEVATOR
P-1
ELEVATOR
LOBBY
N-334
UTILITY
N-335
JAN. CLO
N-336
STAIR
LOUNGE
N-310
BERTHING
UNIT
N-312
BERTHING
UNIT
N-314
BERTHING
UNIT
N-316
BERTHING
UNIT
N-318
BERTHING
UNIT
N-320
BERTHING
UNIT
N-322
BERTHING
UNIT
N-324
BERTHING
UNIT
N-326
BERTHING
UNIT
N-328
CORRIDOR
N-333
BERTHING
UNIT
N-307
BERTHING
UNIT
N-305
BERTHING
UNIT
N-303
BERTHING
UNIT
N-301
STAIR
CORRIDOR
N-337
BERTHING
UNIT
N-302
BERTHING
UNIT
N-304
STAIR
BERTHING
UNIT
S-301
BERTHING
UNIT
S-303
BERTHING
UNIT
S-305
BERTHING
UNIT
S-307
CORRIDOR
S-337
BERTHING
UNIT
S-302
BERTHING
UNIT
S-304
BERTHING
UNIT
S-306
BERTHING
UNIT
S-308
ELEVATOR
P-2
ELEVATOR
LOBBY
S-334
UTILITY
S-335
JAN. CLO
S-336
STAIR
BERTHING
UNIT
S-309
BERTHING
UNIT
S-311
BERTHING
UNIT
S-313
BERTHING
UNIT
S-315
BERTHING
UNIT
S-317
BERTHING
UNIT
S-319
BERTHING
UNIT
S-321
BERTHING
UNIT
S-323
BERTHING
UNIT
S-325
BERTHING
UNIT
S-327
STAIR
BERTHING
UNIT
S-328
BERTHING
UNIT
S-326
BERTHING
UNIT
S-324
BERTHING
UNIT
S-322
BERTHING
UNIT
S-320
BERTHING
UNIT
S-318
BERTHING
UNIT
S-316
BERTHING
UNIT
S-314
BERTHING
UNIT
S-312
BERTHING
UNIT
S-310
CORRIDOR
S-333
STAIR #5
R 76
P
STAIR #4
R 76
P
STAIR #1
R 75
P
STAIR #2
R 76
P
STAIR #3
R 76
P
STAIR #6
R 75
P 123
EE E
E E E
OCCUPANCY CLASSIFICATIONS:
RESIDENTIAL
BUSINESS
BUSINESS (LESS THEN 50 PEOPLE)
BUILDING SUPPORT
NOT OCCUPIED
NORTH
A
C
B D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
:0 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-103
N40085-20-R-0034
L
IF
E
S A F E T Y
O V E R A L L
T H
IR
D
F L O O R
P L A N
L S
12806956
PSM PSM CMA
SCALE: 1 : 150
LIFE SAFETY THIRD FLOOR OVERALL PLAN
A1
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
M
L
F
G
H
K
J
BERTHING
UNIT
N-307
BERTHING
UNIT
N-305
BERTHING
UNIT
N-303
BERTHING
UNIT
N-301
STAIR
CORRIDOR
N-337
BERTHING
UNIT
N-302
BERTHING
UNIT
N-304
FE
D
E
9 10 11 12 13 14BBAA
B
C
D
E
F
G
HJ
13 13
STAIR
BERTHING
UNIT
S-301
BERTHING
UNIT
S-303
BERTHING
UNIT
S-305
BERTHING
UNIT
S-307
CORRIDOR
S-337
BERTHING
UNIT
S-302
BERTHING
UNIT
S-304
BERTHING
UNIT
S-306
BERTHING
UNIT
S-308
ELEVATOR
P-2
ELEVATOR
LOBBY
S-334
UTILITY
S-335
JAN. CLO
S-336
STAIR
FE
FE
D
DD
E E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
A
B
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :0
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-103A&B
N40085-20-R-0034
L
IF
E
S A F E T Y
T H
IR
D
F L O O R
P L A N
P A R T
A
B
L S A B
12806957
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY THIRD FLOOR PLAN - PART A
A1
SCALE: 1/8" = 1'-0"
LIFE SAFETY THIRD FLOOR PLAN - PART B
A3
1 PROVIDE GUARDS ALONG THE EXISTING WINDOW (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPE AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
FOUR (4) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPE AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
TWO (2) WIRE BUNDLES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
FOUR (4) 1" TO 6" METAL PIPES AND REPLACE TWO (2) DAMAGED BLOCKS (SEE DETAIL LS-201)
TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
L
G
H
K
J
10 10 10 10 10
STAIR
BERTHING
UNIT
N-327
BERTHING
UNIT
N-325
BERTHING
UNIT
N-323
BERTHING
UNIT
N-321
BERTHING
UNIT
N-319
BERTHING
UNIT
N-317
BERTHING
UNIT
N-315
BERTHING
UNIT
N-313
BERTHING
UNIT
N-311
BERTHING
UNIT
N-309
ELEVATOR
P-1
ELEVATOR
LOBBY
N-334
UTILITY
N-335
JAN. CLO
N-336
STAIR
LOUNGE
N-310
BERTHING
UNIT
N-312
BERTHING
UNIT
N-314
BERTHING
UNIT
N-316
BERTHING
UNIT
N-318
BERTHING
UNIT
N-320
BERTHING
UNIT
N-322
BERTHING
UNIT
N-324
BERTHING
UNIT
N-326
BERTHING
UNIT
N-328
CORRIDOR
N-333
FE
FE FE
D
DD
E E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTHC
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :1
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-103C
N40085-20-R-0034
L
IF
E
S A F E T Y
T H
IR
D
F L O O R
P L A N
P A R T
C
L S C
12806958
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY THIRD FLOOR PLAN - PART C
A1
1 PROVIDE GUARDS ALONG THE EXISTING WINDOW (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) WIRE BUNDLES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
FOUR (4) 1" TO 6" METAL PIPES AND REPLACE TWO (2) DAMAGED BLOCKS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)14
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
B
C
D
E
F
G
HJ
1010101010
BERTHING
UNIT
S-309
BERTHING
UNIT
S-311
BERTHING
UNIT
S-313
BERTHING
UNIT
S-315
BERTHING
UNIT
S-317
BERTHING
UNIT
S-319
BERTHING
UNIT
S-321
BERTHING
UNIT
S-323
BERTHING
UNIT
S-325
BERTHING
UNIT
S-327
STAIR
BERTHING
UNIT
S-328
BERTHING
UNIT
S-326
BERTHING
UNIT
S-324
BERTHING
UNIT
S-322
BERTHING
UNIT
S-320
BERTHING
UNIT
S-318
BERTHING
UNIT
S-316
BERTHING
UNIT
S-314
BERTHING
UNIT
S-312
BERTHING
UNIT
S-310
CORRIDOR
S-333
FE FE
DD DD
E
LIFE SAFETY DRAWING KEYNOTES:
FIRESTOPPING DRAWING KEYNOTES:
CORRIDOR PENETRATIONS KEYNOTES:
0' 1' 2' 4'
SCALE: 1/2" = 1'
0' 2' 4' 8'
SCALE: 1/4" = 1'
0' 16' 32' 64'
SCALE: 1/32" = 1'
0' 8' 16' 32'
SCALE: 1/16" = 1'
0' 4' 8' 16'
SCALE: 1/8" = 1'
NORTH
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S Y M
D E S C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE
ASSOCIATES
1000 Massachusetts Avenue Cambridge, Massachusetts 02138 P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
R C M A
P ro je c ts C M A
N A V S U B A S E
N e w
L o n d o n
C T
B ld g
T a s k
D e ta il e d
D e s ig n R E V
IT
D e s ig n F in a l D e s ig n
M o d e l\ C e n tr a l_ F P p m o tt o la .r v t
As indicated
:5 :2
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
LS-103D
N40085-20-R-0034
L
IF
E
S A F E T Y
T H
IR
D
F L O O R
P L A N
P A R T
D
L S D
12806959
PSM PSM CMA
SCALE: 1/8" = 1'-0"
LIFE SAFETY THIRD FLOOR PLAN - PART D
A1
1 PROVIDE GUARDS ALONG THE EXISTING WINDOW (SEE ARCHITECTUAL DRAWINGS)
2 PROVIDE GUARDS ALONG THE EXISTING STAIRS (SEE ARCHITECTUAL DRAWINGS)
EIGHT (8) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-200)
TWO (2) 1" TO 6" METAL PIPES AND TWO (2) 1/4" TO 3" METAL CONDUITS (SEE DETAIL LS-201)
PROVIDE AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, WITH AN F RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF THE WALL PENETRATED FOR THE FOLLOWING PENETRATIONS:
CORRIDOR PENETRATIONS ARE REQUIRED TO RESIST THE PASSAGE OF SMOKE. PROVIDE A
SMOKE TIGHT SEAL FOR THE FOLLOWING PENETRATIONS:
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
FFEEDDCCBBAA
M
L
B
C
D E
F
G
H
K
J
TD = 66 FT TD = 86 FT TD = 128 FT TD = 96 FT
TD = 118 FT TD = 104 FT TD = 66 FT TD = 76 FT
STAIR
BERTHING
UNIT
N-427
BERTHING
UNIT
N-425
BERTHING
UNIT
N-423
BERTHING
UNIT
N-421
BERTHING
UNIT
N-419
BERTHING
UNIT
N-417
BERTHING
UNIT
N-415
BERTHING
UNIT
N-413
BERTHING
UNIT
N-411
BERTHING
UNIT
N-409
BERTHING
UNIT
N-410
BERTHING
UNIT
N-412
BERTHING
UNIT
N-414
BERTHING
UNIT
N-416
BERTHING
UNIT
N-418
BERTHING
UNIT
N-420
BERTHING
UNIT
N-422
BERTHING
UNIT
N-424
BERTHING
UNIT
N-426
BERTHING
UNIT
N-428
CORRIDOR
N-433
UTILITY
N-435
ELEVATOR
P-1
ELEVATOR
LOBBY
N-434
STAIR
JAN. CLO
N-436
BERTHING
UNIT
N-408
BERTHING
UNIT
N-406
BERTHING
UNIT
N-404
BERTHING
UNIT
N-402
BERTHING
UNIT
N-401
BERTHING
UNIT
N-403
BERTHING
UNIT
N-405
BERTHING
UNIT
N-407
CORRIDOR
N-437
STAIR
STAIR
BERTHING
UNIT
S-401
BERTHING
UNIT
S-403
BERTHING
UNIT
S-405
BERTHING
UNIT
S-407
UTILITY
S-438
BERTHING
UNIT
S-409
BERTHING
UNIT
S-411
BERTHING
UNIT
S-413
BERTHING
UNIT
S-415
BERTHING
UNIT
S-417
BERTHING
UNIT
S-419
BERTHING
UNIT
S-421
BERTHING
UNIT
S-423
BERTHING
UNIT
S-425
BERTHING
UNIT
S-427
STAIR
BERTHING
UNIT
S-428
BERTHING
UNIT
S-426
BERTHING
UNIT
S-424
BERTHING
UNIT
S-422
BERTHING
UNIT
S-420
BERTHING
UNIT
S-418
BERTHING
UNIT
S-416
BERTHING
UNIT
S-414
BERTHING
UNIT
S-412
LOUNGE
S-410
UTILITY
S-435
ELEVATOR
P-2
JAN. CLO
S-436
STAIR
ELEVATOR
LOBBY
S-434
BERTHING
UNIT
S-408
BERTHING
UNIT
S-406
BERTHING
UNIT
S-404
BERTHING
UNIT
S-402
CORRIDOR
S-437
CORRIDOR
S-433
STAIR #5
R 76
P
STAIR #4
R 76
P
STAIR #1
R 80
P
STAIR #2
R 81
P
STAIR #3
R 81
P
STAIR #6
R 75