This solicitation package includes structural drawings and specifications for repair work on a submarine training facility. The project scope involves whole building repairs to a 109,442 square foot building including upgrading fire protection, interior finishes, HVAC, plumbing and exterior enclosure repairs. Additional work includes constructing a new sidewalk, site grading to direct water away from foundations, and interior repairs such as to elevators and electrical systems. The solicitation was issued by the Department of the Navy Naval Facilities Engineering Command for repairing Building 488 at the New London, Connecticut submarine base to restore quality and adequacy to the 188-bed enlisted housing facility. The response due date is not provided in the documents reviewed.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOR EXISTING
HOLES IN PRECAST
PLANK THAT ARE
NOT BEING USED
FOR MECH OR
PLUMBING, FILL WITH
NON-SHRINK GROUT.
2' - 0"
8"
PROVIDE FORM TO
PREVENT GROUT
FROM FILLING CELL
SECTION AA
SECTION BB
B B
A A
NOTE: FIELD IDENTIFY EXISTING CORES AFTER FINISHES HAVE BEEN
REMOVED. CONTACT ENGINEER IF STRANDS HAVE BEEN COMPROMISED.
PROVIDE CORES AS
REQUIRED FOR
MECHANICAL,
ELECTRICAL AND
PLUMBING WORK.
CENTER CORE
BETWEEN FIELD
LOCATED STRANDS.
MAXIMUM CORE
SIZE IS 6"
DIAMETER.
2' - 0"
8"
SECTION AA
SECTION BB
B B
A A
FIELD LOCATE
STRANDS PRIOR TO
CORING. DO NOT
DAMAGE STRANDS
DURING CORING
NOTE: COORDINATE CORE LOCATIONS WITH
MEP/FP DRAWINGS.
NOTE: COORDINATE LOCATIONS
OF OPENINGS WITH MEP/FP
DRAWINGS.
ø 0' - 6" MAX
PROVIDE CORES AS REQUIRED FOR MECHANICAL,
ELECTRICAL AND PLUMBING WORK. CORE WALL FOR
PIPE PENETRATIONS. CENTER VERTICALLY IN CMU
UNIT. LIMIT TO ONE CORE PER BLOCK. PROVIDE THREE
CORE DIAMETERS CLEAR BETWEEN EACH CORE.MIN
3Ø CLEAR
MAX
2' - 0" WIDE OPENING
M A
X
2'
0" H
IG
H
O P
E N
IN
G
L6x6x5/16 LINTEL, MINIMUM OF 8" BEARING EACH
END.
TYP
8" MIN
CHIP AND REMOVE CMU FOR PLUMBING OPENING.
LIMIT OF ONE OPENING PER BEARING WALL PER
FLOOR. CONTACT ENGINEER WITH DISCREPANCIES.
C4
S-001
C4 WHERE PLUMBING CARRIER IS REQUIRED.
MAX
2' - 0" WIDE OPENING
2' -0
H
IG
H
M A
X
CHIP AND REMOVE 6" THICK CMU BLOCK AS
SHOWN TO PROVIDE TEMPORARY ACCESS
FOR MEP WORK. DO NOT CUT VERTICAL
REINFORCING IF ENCOUNTERED. REPAIR
WALL BY TOOTHING NEW BLOCK THAT
MATCHES EXISTING. IF VERTICAL
REINFORCEMENT IS PRESENT, CUT A
VERTICAL SLOT IN THE FRONT OF BLOCK AND
SLIDE IN PLACE FROM BEHIND. FOR BOND
WITH HORIZONTAL REINFORCEMENT, EPOXY
DOWEL NEW REBAR TO MATCH REMOVED
REBAR FROM BOND BEAM. EPOXY
EMBEDMENT TO HAVE EMBED STRENGTH
EQUAL TO BAR YIELD IN BOND BEAM. FORM
AND GROUT CELLS CONTAINING REBAR.
NOTE: WALL IS A LOAD BEARING WALL AND
PART OF THE GRAVITY LOAD RESISTING
SYSTEM. CONTRACTOR TO PROVIDE
SHORING DESIGNED BY A REGISTERED
DESIGN PROFESSIONAL TO COMPLETE THE
WORK SAFELY AND TO PREVENT DAMAGE
TO THE BUILDING.
VIF
5 3/8"
VIF
9 3/4"
VIF
5 3/8"
ANGLE FRAME, L3x3x5/16, FACE
VERTICAL LEG DOWNWARDS
2" T
Y P
COORDINATE WITH
PLUMBING, CARRIER
ATTACHMENT
REQUIREMENTS
FASTEN ANGLE FRAME WITH
1/4" CONCRETE SCREWS TO
PRECAST PLANK
PROVIDE THREADED STUD
WELDED TO ANGLE FRAME.
COORDINATE DIAMETER,
NUMBER, AND LOCATION WITH
CARRIER SELECTED
Net Wind Pressures for Components and Cladding-Alternate Method 2 IBC 2015§1609.6
Refer to ASCE 7-10 Figure 30.4-2B Refer to ASCE 7-10 Figure 30.4-1
Element Zone Pressure
Direction Area
Pnet
Roof Zone 1 Positive
Negative
10 SF
100 SF
Wall Zone 4 54.6
-59.5
41.0
44.8
54.6
73.2
41.0
54.6
PSF
31.7
-54.6
22.4
-50.3
31.7
-91.8
22.4
-63.9
31.7
-138.2
22.4
-101.0
Element Zone Pressure
Direction Area
Pnet
PSF
Roof Zone 1
Roof Zone 1
Roof Zone 1
Roof Zone 2
Roof Zone 2
Roof Zone 2
Roof Zone 2
Roof Zone 3
Roof Zone 3
Roof Zone 3
Roof Zone 3
Positive
Negative
10 SF
100 SF
Positive
Negative
10 SF
100 SFPositive
Negative
10 SF
100 SF
Positive
Negative
10 SF
100 SFPositive
Negative
10 SF
100 SF
Positive
Negative
10 SF
100 SFPositive
Negative
10 SF
100 SF
Positive
Negative
10 SF
100 SFPositive
Negative
10 SF
100 SF
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Zone 4
Zone 4
Zone 4
Zone 5
Zone 5
Zone 5
Zone 5
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S
YM
D
ES
C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE ASSOCIATES
1000 Massachusetts Avenue
Cambridge, Massachusetts 02138
P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
Y D o c u m e n ts R e v it L o c a l\ C e n tr a l_ S D y la n Q u in n .r v t
As indicated
:3 :3
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
S-001
N40085-20-R-0034
S T R U C T U R A L
S
12806864
DQ DQ BWD
Q U
IN
N
GENERAL CONSTRUCTION REQUIREMENTS:
STRUCTURAL DRAWINGS MUST BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SHOP DRAWINGS, AND SPECIFICATIONS.
DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD, AND DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH THE AFFECTED PORTION OF THE WORK.
SHOP DRAWINGS FOR REINFORCING STEEL (INCLUDING ACCESSORIES), STRUCTURAL STEEL, COLD FORM FRAMING, AND STEEL DECKING, MUST BE SUBMITTED TO THE STRUCTURAL ENGINEER, AND A STAMPED APPROVAL RECEIVED BEFORE FABRICATION CAN PROCEED. ERECTION MUST BE EXECUTED FROM APPROVED SHOP DRAWINGS ONLY.
A COMPLETE CONCRETE PLACEMENT SCHEDULE MUST BE SUBMITTED TO THE STRUCTURAL ENGINEER AND A
STAMPED ACCEPTANCE RECEIVED BEFORE CONCRETE PLACEMENT CAN BE MADE.
UNLESS OTHERWISE NOTED, DETAILS SHOWN ON DRAWINGS ARE CONSIDERED TYPICAL FOR SIMILAR CONDITIONS.
REFERENCED STANDARDS:
IEBC 2015 ICC INTERNATIONAL EXISTING BUILDING CODE
UFC 1-200-01 GENERAL BUILDING REQUIREMENTS
ASCE 7-10 MINIMUM LOADS FOR BUILDINGS AND OTHER STRUCTURES
ACI 318-14
AISC 360-10
DESIGN LOADS:
LIVE (SUPERIMPOSED) LOADS: (SEE NAVFAC DWG NO 2043535)
DORM ROOMS: 50 PSF
LAVATORIES: 100 PSF
CORRIDORS: 110 PSF
SNOW:
Pg = 30 PSF Is = 1.0 Ct = 1.0 Ce = 1.0 Pf = 21 PSF
(PROVIDED FOR REFERENCE)
WIND DESIGN DATA:
Vult = 135 mph Vasd = 105 mph
RISK CATEGORY: II
WIND EXPOSURE: C
GCpi = +/-0.18
EARTHQUAKE DESIGN DATA:
RISK CATEGORY: II
Ie = 1.0
SS = 0.16
S1 = 0.06
SITE CLASS: D (ASSUMED)
SDS = 0.17
SD1 = 0.10
DESIGN CATEGORY: B
DESIGN CRITERIA:
LINTEL DEFLECTION LIMIT OF L/600
STRENGTH LIMIT STATES DEFINED BY APPLICABLE MATERIAL CODE
FOUNDATION CONDITIONS:
EXISTING FOUNDATIONS ARE SHALLOW AND BEAR ON ROCK WITH AN ALLOWABLE CAPACITY OF 20 KSF PER NAVFAC DRAWING NUMBER 2043541 DATED 3-9-83.
STRUCTURAL STEEL
FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH THE "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND THE "CODE OF STANDARD PRACTICE" OF THE AISC. WELDING SHALL CONFORM TO THE REQUIREMENTS OF THE "STRUCTURAL WELDING CODE" OF THE AMERICAN
WELDING SOCIETY.
STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. STRUCTURAL STEEL CHANNELS SHALL CONFORM TO ASTM A572, GRADE 50.
STRUCTURAL TUBES SHALL BE ASTM A500, GRADE B. STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53, GRADE B. STRUCTURAL STEEL
PLATES AND ANGLES SHALL CONFORM TO ASTM A36, UNLESS OTHERWISE NOTED.
DO NOT SPLICE STRUCTURAL STEEL MEMBERS OR PROVIDE PENETRATIONS IN STEEL MEMBERS WITHOUT WRITTEN APPROVAL OF THE STRUCTURAL
ENGINEER.
BOLTED CONNECTIONS SHALL BE MADE WITH THREE-QUARTERS INCH DIAMETER HIGH STRENGTH, ASTM A325-N BOLTS, UNLESS OTHERWISE NOTED.
CONNECTIONS AT HANGERS SHALL BE MADE WITH THREE-QUARTERS INCH DIAMETER A325-SC (SLIP CRITICAL) BOLTS, UNLESS OTHERWISE NOTED.
WELDING ELECTRODES SHALL CONFORM TO AWS A5.1 E70XX SERIES WITH PROPER ROD TO PRODUCE OPTIMUM WELD (LOW HYDROGEN).
PROVIDE 1/4" THICK LEVELING PLATE UNDER ALL COLUMN BASE PLATES UNLESS OTHERWISE NOTED.LEVELING PLATES SHALL BE SET AND GROUTED
PRIOR TO ERECTING COLUMNS AND POSTS.
PROVIDE ALL ANGLES, PLATES, ANCHORS, BOLTS, ETC., SHOWN ON ARCHITECTURAL DRAWINGS.
LINTELS FOR EXTERIOR MASONRY AND STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED ACCORDING TO ASTM A123.
GROUT
GROUT MUST CONFORM TO ASTM C476, AND MUST HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF AT LEAST 2,500 PSI.
PROVIDE TESTING FOR GROUT COMPRESSIVE STRENGTH AND EXPANSION FOR QUALITY ASSURANCE.
SCALE: 1 1/2" = 1'-0"
TYPICAL EXISTING HOLE INFILL
A3
SCALE: 1 1/2" = 1'-0"
TYPICAL PLANK CORING
C3
SCALE: 3/4" = 1'-0"
PENETRATION IN EXISTING CMU BEARING
WALL
D4
SCALE: 3/4" = 1'-0"
TEMPORARY PENETRATION IN CMU BEARING
WALL
A4
SCALE: 1" = 1'-0"
CARRIER SUPPORT FRAME
C4
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
2 0
CONCRETE
CONCRETE MUST BE A MIX DESIGNED FOR ULTIMATE STRENGTH CONCRETE IN ACCORDANCE WITH
ACI 211.1 TO ACHIEVE THE FOLLOWING 28-DAY COMPRESSIVE STRENGTHS 3500 PSI, NORMAL
WEIGHT.
PROVIDE CONCRETE TESTING INCLUDING SLUMP AND 28 DAY COMPRESSION TESTS FOR QUALITY
ASSURANCE.
REINFORCING STEEL
REINFORCING STEEL MUST BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND
CONFORMING TO ASTM A615, GRADE 60.
LAP REINFORCING TO DEVELOP THE FULL TENSION CAPACITY OF THE (SMALLER) BAR.
COLD FORM METAL FRAMING
PROVIDE METAL FRAMING WITH Fy = 50ksi.
Brett Wilkinson
T Y
P
2'
0"
EXISTING MASONRY
WALLS BELOW
EXISTING PRECAST
PLANKS
JOINT OVER BEARING
WALL
VIF
3' - 6"
V
IF
7'
6"
EXISTING
MECHANICAL SHAFT
OPENING IN ROOF FOR
MECHANICAL DUCT, SEE
MECHANICAL FOR LOCATION
SEE MECH
S E
E M
E C
H
L6x4x3/8 ANGLE
FRAME, LLH
EPOXY GROUTED
ANCHOR AT BEARING
WALL, TYP
EPOXY GROUTED
ANCHOR AT
EACH CELL OF
CUT PLANK, TYP.
B1
S-002
EXISTING PRECAST
PLANKS
L6x4x3/8 ANGLE
FRAME, LLH
EPOXY GROUTED ANCHOR
(HILTI HY-70 OR APPROVED
EQUIVALENT) AT EACH
CELL OF CUT PLANK, TYP.
OPENING
NOTE: ANGLE FRAME
TO BE INSTALLED
PRIOR TO CUTTING OF
PRECAST PLANK
EXISTING 5"± CONCRETE
SLAB
DRILL 5/8"Ø x 6" DEEP HOLES
AND EPOXY GROUT #4@
24"o.c. DOWELS INTO EXIST.
EACH EDGE. SLAB AT MID
DEPTH (TYP)
PROVIDE 6x6-W2.9xW2.9
W.W.F. AT MID DEPTH (TYP)
CONCRETE SLAB INFILL
NOTE:
UNLESS OTHERWISE
SPECIFIED, EPOXY ADHESIVE
SHALL BE "HILTI HIT-HY500 RE"
INJECTION SYSTEM OR
APPROVED EQUAL.
COMPACTED GRAVEL FILL
TO 95% MAX. DRY DENSITY,
SEE EARTHWORK
SPECIFICATIONS
TYP.
6"
RETURN AND GROUT
BARS INTO EXIST. SLAB
AT 48" O.C. IN SHORT
DIRECTION ONLY
"HILTI HY-HIT 200 SAFE
SET" SYSTEM
ADHESIVE (TYP) OR
APPROVED EQUAL
6"± EXIST.
SLAB-ON-GRADE
#4@12" E.W.AT 4"
PAD, #5@12" AT
12" PAD
APPLY BONDING AGENT SIKA
ARMATEC 110 OR APPROVED
EQUAL
NOTES:
1. SEE ELECTRICAL, MECHANICAL, AND PLUMBING DRAWINGS FOR EQUIPMENT
REQUIRING HOUSEKEEPING PADS AND SEE VENDOR DRAWINGS FOR PAD SIZE,
ANCHORING, AND BOLT PLAN. IF NO DIMENSIONS ARE SHOWN PROVIDE
RECTANGULAR PADS 4" BEYOND EQUIPMENT, ALL AROUND.
2. POWERWASH EXISTING CONCRETE SURFACE TO RECEIVE PAD. REMOVE
CONTAMINANTS, ETC.
3. PROVIDE PAD WITH 1" CHAMFERED EDGE, ON THREE EXPOSED SIDES OF PAD.
4. PROVIDE GROUNDING PER STANDARDS.
LENGTH AS REQUIRED
5"
12" AT LOCATIONS
INDICATED ON MEP
DRAWINGS, 4" U.N.O.
1 1/2" TYPE B20 METAL
ROOF DECK.
16 GA. PLATE FOR DECK EDGE. FASTEN
TO LEDGER WITH 2 ROWS OF #8
SCREWS AT 24" ON CENTER. SPACE
ROWS 4" APART.
600S162-68 LEDGER. FASTEN TO ANGLE
WITH 2 ROWS OF 2 #10 SCREWS,
SPACED 2" ON-CENTER EACH WAY.
600S162-54 ROOF JOIST, SPACE 24" ON
CENTER.
SIMPSON STRONG TIE LSSC 4.25 OR
APPROVED EQUAL. INSTALL PER
MANUFACTURER'S INSTRUCTIONS.
L6x4x3/8x1'2". CENTER ON EXISTING IN
PLACE STEEL. PROVIDE LONG
SLOTTED HOLE IN HORIZONTAL LEG,
PERPENDICULAR TO EXISTING. LONG
SLOTTED HOLE. FASTEN TO EXISTING
STEEL WITH 5/8" Ø A325 BOLT.
EXISTING PLATE WITH LONG SLOTTED
HOLE. FIELD VERIFY CONDITION.
PROVIDE LONG SLOTTED HOLE IN
PLATE IF NOT PRESENT.
EXISTING
STRUCTURAL STEEL.
FIELD VERIFY.
EXISTING BRICK
VENEER.
4x6x1/4" SLIDE
BEARING PAD
SEE C3/S-002 FOR ROOF DECK AND ROOF FRAMING.
SIMPSON STRONG TIE FCB45.5 WITH 3 ANCHORS.
600T250-54 TOP TRACK
1.5 X 18 GA STEEL STRAP X-BRACING. PROVIDE X-BRACE
5'-0" ON CENTER. FASTEN AT TOP AND BOTTOM WITH 2 #10
SCREWS. SEE C1/S-004
L3X3X18 GA CONTINUOUS ANGLE. FASTEN TO ROOF DECK
WITH #10 SCREWS AT 12" ON CENTER
1/4"x12" CONTINUOUS PLATE
2-12
EXISTING STRUCTURE
600T250-54 BOTTOM TRACK
PROVIDE CONTINUOUS
BENTONITE WATERSTOP
ALL AROUND (TYP. WHERE
SHOWN)
#5 @ 12" EACH WAY
BOTTOM (TYP)
#5 DWLS. @ 12" (TYP)
48" LAP SPLICE
#5@12" VERT. (TYP)
#4@12" HORIZ. (TYP)
T.O. SLAB EL.
2x4 KEY (TYP) w/
CONT. WATERSTOP
6"
8" 8"4' - 0" EA. WAY
T.O. SLAB EL.
SEE A1/S-002
FOR SLAB
INFILL
EXIST. CMU
WALL
EXIST. CONC.
FDN WALL
PROJECT
NORTH
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S
YM
D
ES
C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE ASSOCIATES
1000 Massachusetts Avenue
Cambridge, Massachusetts 02138
P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
KEY PLAN
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
Y D o c u m e n ts R e v it L o c a l\ C e n tr a l_ S D y la n Q u in n .r v t
As indicated
:3 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
S-002
N40085-20-R-0034
S T R U C T U R A L
S
12806865
DQ DQ BWD
Q U
IN
N
SCALE: 3/4" = 1'-0"
PLAN OF ROOF OPENING
C1
SCALE: 1 1/2" = 1'-0"
MECH OPENING
B1
APPROXIMATE
LOCATIONS OF
OPENINGS AT ROOF
LEVELS
SCALE: 1 1/2" = 1'-0"
TYPICAL SLAB INFILL DETAIL
A1
SCALE: 1/2" = 1'-0"
TYPICAL HOUSEKEEPING PAD DETAIL
A3
SCALE: 1 1/2" = 1'-0"
BID OPTION 8B SHED ROOF AT WALL
C3
SCALE: 1 1/2" = 1'-0"
BID OPTION 8B -SHED ROOF AT ROOF
C5
NOTE: ANGLE FRAME TO BE INSTALLED PRIOR TO
CUTTING OF PRECAST PLANK
SCALE: 1/2" = 1'-0"
TYPICAL PIT DETAIL
B4
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
2 0
BB AA
1.5 X 18 GA STEEL STRAP
X-BRACING. PROVIDE X-
BRACE 6'-0" ON CENTER.
FASTEN AT TOP AND
BOTTOM WITH 2 #10
SCREWS. SEE C1/S-004 L3X3X18 GA
CONTINUOUS ANGLE.
FASTEN TO ROOF DECK
WITH #10 SCREWS AT
12" ON CENTER
EXISTING STRUCTURE, TYP
VIF
7' - 8" VIF
3"x3/8" PLATE WITH 2
3/4" Ø A325 BOLTS,
TYP.
TYP. M
A
TC
H
E X
IS
TI
N G
R
ID
G E
2" V
IF
16 GA. RIDGE PLATE
16 GA CLOSURE
PLATE
C6x8.2 BENT BEAM AT
5' - 0" ON CENTER
WORK POINT
1 1 /2"
3"
1/
2"
C4
S-003
S E
E A
R C
H
SEE ARCH
4' - 6" MAX
MIN.
8"
BOT. OF FLOOR PLANK
TOP OF FLOOR
PLANK OR SLAB
2 L3-1/2x2-1/2x5/16
LLV
OPEN
NOTE: GROUT REINFORCED COURSE SOLID.
6"
FULLY GROUTED CELL
UNDER BEARING
LOCATION, REINFORCE
WITH #4
HH
HH
II
II
15' - 6" 15' - 6" 15' - 6"
EX. W BEAM EX. W BEAM
EX. W BEAM
EX. W BEAM
EX. W BEAM
EX. W BEAM
A T
2' -0
O
.C
0S
2-
A T
2' -0
O
.C
0S
2-
A T
2' -0
O
.C
0S
2-
A T
2' -0
O
.C
0S
2-
EX. W BEAM
AT 2'-0" O.C.
600S162-43
A4
S-003
A4
S-003
A4
S-003
A4
S-003
A4
S-003
A4
S-003
SIM.
SIM SIM
SIM
SIM
EX. W-SHAPE
BEAM
EX. PRECAST PLANK
EX. BRICK
VENEER (4) - #10 SCREWS
LGMF, SEE PLAN
ALIGN VERTICAL WITHIN 2" OF
PRECAST ANCHOR
600S162-43 VERTICAL STUD
600T250-43 CONTINUOUS TOP TRACK
HILTI HY70 W/ 3/8 THREADED
ROD, SPACED 2'-0" O.C. (1 PER
PLANK)
FIELD LOCATE STUDS BEFORE
INSTALLATION
3"
A R
C H
S E
E
EXISTING ANGLE, VIF
1.5 X 18 GA STEEL STRAP X-
BRACING. PROVIDE X-BRACE
5'-0" ON CENTER. FASTEN AT
TOP AND BOTTOM WITH 2 #10
SCREWS. SEE C1/S-004
600S250-43 BLOCKING
PROVIDE 600S162-43
KICKER AT EVERY
OTHER STUD, FASTEN
2ITH (30 #10 SCREWS
EACH END
EXISTING MASONRY
WALL
2" MAX
5' - 0" O.C. SPAN
EXIST. HSS
BENT CHANNEL, ABUT TO EXISTING ROOF
LAP ROOF DECK 2' - 0" OVER EXISTING WITH 2 ROWS
OF #10 SCREWS AT EACH FLUTE TO FASTEN DECK TO
EXISTING. IF DECK IS UNABLE TO BE LAPPED, PROVIDE
2'-0" 16GA CLOSURE PLATE (1'0" EACH DECK) AND
FASTEN TO EACH DECK WITH 2 ROWS OF #10 SCREWS
AT 6" ON CENTER
EX. ROOF DECK
LAP ROOF DECK
2' - 0"
EX. ROOF FRAMING
EXIST. LGMF
EXIST. W BEAM
C3
S-002
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S
YM
D
ES
C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE ASSOCIATES
1000 Massachusetts Avenue
Cambridge, Massachusetts 02138
P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
Y D o c u m e n ts R e v it L o c a l\ C e n tr a l_ S D y la n Q u in n .r v t
As indicated
:3 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
S-003
N40085-20-R-0034
S T R U C T U R A L
S
12806866
DQ DQ BWD
Q U
IN
N
SCALE: 3/4" = 1'-0"
C3/BID OPTION 8D
C3
SCALE: 1/2" = 1'-0"
REINFORCED OPENING DETAIL
C1
SEE ARCH FOR
EXTENTS.
SCALE: 1/8" = 1'-0"
SOFFIT FRAMING PLAN
A1
NOTES:
1. PROVIDE STRAP BRACING AT 3'-0" ON CENTER
2. REFER TO ARCHITECHUAL DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
SCALE: 1" = 1'-0"
LGMF SOFFIT AT WALL
A4
SCALE: 3/4" = 1'-0"
C4/BID OPTION 8D
C4
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
2 0
NOTE: CONDITION IS
SIMILAR WHERE SHOWN
ON ARCH DRAWINGS
TOP TRACK AS
INDICATED FROM
SECTION
BLOCKING OR ANGLE
AS INDICATED FROM
SECTION
VERTICAL STUD
AS INDICATED FROM
SECTION
STRAP BRACING AS
INDICATED FROM
SECTION
BRACING SPACING, SEE SECTION
DD
Level 0-6 211' - 0"
1ST FLOOR
211' - 0"
WELD 3/8" SHEAR
PLATE TO EXISTING
COLUMN, PROVIDE
TWO A325 3/4" DIA
BOLTS
EXIST. W SHAPE
COLUMN
EXISTING
OPENING IN
MASONRY
WALL
REMOVE FACE OF
SINGLE CELL OF CMU
(BEHIND BRICK
VENEER) AND PROVIDE
#5 CONTINUOUS REBAR
TO FOUNDATION .
GROUT CMU SOLID
3/8" STIFF. PLATE B/S
W8X21
6 1/2"X5"X3/8" CAP
PL. FIELD WELD TO
PLATE TO BEAM
WITH ALL AROUND
FILLET WELD
HSS6X4X3/8
EXIST. 6"
MASONRY
WALL
4'
0" L
A P
DRILL AND ANCHOR #5 REBAR INTO EXISTING
FOUNDATION, PROVIDE EPOXY ANCHOR THAT
ACHIEVES FULL YELD STRENGTH OF BAR,
TYP.
5 - EQ. SPACED 3/4"
DIA. HILTI HAS RODS
W/ HILTI HY-70
ADHESIVE w/ 6" MIN.
EMBEDMENT w/ 2 1/2" x 2 1/2" x 1/4"
PLATE WASHER
ACCESS HOLE
(TYP)
SEE DETAIL
H6/S402
FIELD COORDINATE
8" SOLID BEARING ON
FULL CMU CELL.
LOCATED AT FIRST
CELL THAT CLEARS
EXISTING SCREENWALL
EMBED PLATE, 1/4" X
3 1/2" X 7 1/2" WITH
(2) 1/2" Ø X 4 1/2"
HEADED STUDS, TYP
AT BEAM ENDS
FIELD COORDINATE
1/2"X8"X12" BASE PLATE ON 3/4" GROUT WITH
(2) 3/4" DIA HILTI HAS ANCHORS WITH HY-200
ADHESIVE.
A4
S-004
ALIGN CENTER BEAM AND
POST WITH CETNER OF CMU
ARHCITECTURAL
GLASS CURTAIN
FRAMING TO REMAIN IN
PLACE. BRICK VENEER
AT FRAME TO REMAIN
IN PLACE.
PROVIDE CMU SOAP
ON EXPOSED SIDE
EXIST. MASONRY WALL
UNDERSIDE OF LINTEL EL.
SEE ARCH.
NEW HSS 1 BOLTED
TO EXISTING WALL,
6"
ACCESS HOLE IN TUBE
FOR BOLTING
PACK GROUT FOR CONTINOUS
BEARING OF CMU
1/4" 2-6
CONTINOUS 3/8" A36 STEEL
PLATE FOR BRICK VENEER AT
LOCATIONS OF OPENINGS. SEE
ARCH DRAWINGS FOR OPENING
SIZE AND LOCATIONS.
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
UNCLASSIFIED
U N C
LA
S S
IF
IE
D
UNCLASSIFIED
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S
YM
D
ES
C R
IP
TI
O N
D
AT
E
AP
P R
DRAWFORM REVISION: 12 APRIL 2018
SYMMES MAINI & McKEE ASSOCIATES
1000 Massachusetts Avenue
Cambridge, Massachusetts 02138
P: 617.547.5400 F: 617.648.4920
F
IL
E
N A M E
L A Y O U T
N A M E
P L O T T E D
U S E R
OF 342
01/10/2020
APPROVED BY
JOHNATHAN JOHNS PM&EB Supervisor with NAVAL BASE, New London, CT
MRI/LEJ
EA
Y D o c u m e n ts R e v it L o c a l\ C e n tr a l_ S D y la n Q u in n .r v t
As indicated
:3 :4
P M
P R
O
JE
C T
R M
-1
R
E P
A
IR
F A
IL
IN
G
S U
B M
A R
IN
E
A S
C H
O O
L B
Q
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
Y B
AS
E
N E W
LO
N D O N
N E W
LO
N D O N C T
N
AV
S U B
AS
E
P U B
LI
C
W O R K S
D E P
AR
TM
E N T
1600393
S-004
N40085-20-R-0034
S T R U C T U R A L
S
12806867
DQ DQ BWD
Q U
IN
N
SCALE: 1 1/2" = 1'-0"
LGMF X-BRACING
C1
SCALE: 3/4" = 1'-0"
SECTION
B4
SCALE: 1" = 1'-0"
SECTION
A4
IS
SU
E
FO
R
C O N
ST
RU
C
TI
O N
2 0
| STRUCTURAL |
| S-001 - STRUCTURAL |
| S-002 - STRUCTURAL |
| S-003 - STRUCTURAL |
| S-004 - STRUCTURAL |
2020-02-12T09:12:11-0500
2020-02-12T09:12:37-0500
2020-02-12T09:12:39-0500
2020-02-12T09:12:40-0500
2020-02-12T15:48:37-0500
2020-02-12T15:50:29-0500
2020-02-12T15:50:30-0500
2020-02-12T15:50:31-0500
| 2020-02-14T11:35:07-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:29-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:29-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:30-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:40-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:52-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:52-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-14T11:35:53-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
File details come from the government source that posted it. Updated .