MARSOC_MEC-A-3_INTERIOR_SNIPER.pdf
PDF 284 KB Posted
- Solicitation number
- N4008519R9048
About this file
This file contains construction drawings and specifications for a proposed sniper range at Marine Corps Base Camp Lejeune in North Carolina. The drawings depict elevation plans and details for three sniper range areas including the up range, mid range, and down range segments. Specifications address ballistic protection requirements for walls and ceilings, maintenance responsibilities, and notes regarding lead handling and air filtration system operations.
The related federal contract opportunity is a multiple award construction contract for large construction projects at Marine Corps bases in North Carolina. Solicitation number N4008519R9048 was issued by the Naval Facilities Engineering Command as an indefinite-delivery/indefinite-quantity contract to provide construction services on an as-needed basis. No pricing, response dates, or other contract details are provided in the file beyond identifying the soliciting agency and scope of work involving Marine Corps facilities in North Carolina.
MARSOC MEC-A-3 INTERIOR SNIPER
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A3
SNIPER RANGE ELEVATIONS
SCALE: 1/2" = 1'-0"
SNIPER RANGE ELEVATION PLAN - UP RANGE1
SCALE: 1/2" = 1'-0"
SNIPER RANGE ELEVATION PLAN - MID RANGE2
SCALE: 1/2" = 1'-0"
SNIPER RANGE ELEVATION PLAN - DOWN RANGE3
MA
TC
HL
IN
E A
MA
TC
HL
IN
E B
MA
TC
HL
IN
E A
MA
TC
HL
IN
E
B PRELIMINARY NOT FOR
CONSTRUCTION PER
PENDING APPROVAL
CUSTOMER SELECTS & SIGN OFF:
OPTION: SIGNATURE DATESELECTION
COLOR SELECTION
(TYP) SIERRA TAN
POWER LOCATION
OVERHEAD/ UNDERGROUND
HEATING SOURCE
LP-GAS/ELECTRIC
U.S. PATENT NO. 7,357,394s PAT. NO. 7,357,394
ZINC GREY
ELECTRIC
Lo gi n:
J im R ic ha rd s
P lo t D at e:
0/ 6/
:3
6:
A M
Fi le
P at h S
:\S R
I D oc um en ts a nd P ar ts
\0
D ra w in gs \6
A
IS
P ro po se d\
M A
R S
O C
\M A
R S
O C
M E
C .d w g
P1 Issued for comment JCR
MARINE CORPS SPECIAL
CAMP LEJEUNE, N.C.
JCR 09.07.11 JC 09.07.11JC 09.07.11
SRI11016 AS NOTED
11016 MARSOC P6
ORTHOGRAPHIC PROJECTION
MAINTENANCE AND RESPONSIBILITIES
NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:
Advanced Interactive Systems Inc. (AIS) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by AIS, or anyone affiliated or partnered with
AIS.
AIS, or anyone affiliated or partnered with AIS, will not be held liable for any negligence on the part of the structure personnel for any of the above items.
Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by AIS at time of purchase.
1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. AIS is not responsible for this operation (interlocking system).
2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).
3. Structures must have a negative air pressure or a min. of 10% of total air supply.
4. AIS is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.
5. No storage or work to be performed behind bullet traps at any time.
6. AIS suggests lead handling & employee protection by the manual provided by the
National Shooting Sports Foundation (NSSF).
The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.
It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.
GENERAL NOTES
1. Air system comes as a completely balanced system by factory certified H.V.A.C.
specialists however, it is the customers responsibility to maintain a balanced air system.
2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.
3. AIS has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.
P2 Issued for comment EDM P3 Issued for meeting EDM P4 Issued for approval EDM P5 Issued for approval EDM of
665 Andover Park West Seattle, WA 98188-3321 Tel: (206) 575-9797 Fax: (206) 575-8665 Website: www.ais-sim.com
11 1312 14 15 16
Drawing No.
Project No.
Drawn Date
Scale
Checked Date
Drawing Title
Project Title
Rev.
Approved Date
Client
R ev
Date Amendment
C hk
/A pp
D ra w n
NOTES
C
H
1 2 3
G
F
E
4 5 6 7
D
C
B
A
NOTE:
Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.
Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.
Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.
Written dimensions on these drawings shall have precedence over scaled dimensions.
contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.
Such conflicts noted above shall be reported immediately to the engineer.
The information disclosed in this document contains proprietary data of Advanced Interactive Systems, Inc. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Advanced Interactive Systems, Inc. 665 Andover Park West, Seattle WA 98188-3321. patent pending
17 188
11 1312 14 15 161 2 3 4 5 6 7 17 188 9 10
H
G
F
E
D
C
B
A
Sheet No.
Sheet
P6 Issued for approval JCR
File details come from the government source that posted it. Updated .