NAVADMIN_026.18.pdf

PDF 164 KB Posted

Attached to
P257- Design-Build, Ship Repair Training Facility, Norfolk Naval Shipyard, Portsmouth, Virginia
Solicitation number
N4008518R1107
Issued by

About this file

NAVADMIN_026.18.pdf

View the file

Other files

File Type Posted
AMENDMENT_14.pdf PDF
ITG_2018-02_NAVADMIN_Message_for_AT_Standards.pdf PDF
AMENDMENT_13.pdf PDF
P257_NAVADMIN_026_18_Checklist.pdf PDF
Amendment_12.pdf PDF
Amend_11.pdf PDF
AMENDMENT_10.pdf PDF
AMENDMENT_009.pdf PDF
Amendment_0008.pdf PDF
Section_00_22_13_00_20_revised_4.20.18.pdf PDF
Part_3_Chapter_4,_4th_Floor_Space_Tabulation.pdf PDF
SBSP_(Template).doc DOC document
AMENDMENT_07.pdf PDF
AMENDMENT_06.pdf PDF
p257SiteVisitLog.pdf PDF
AMENDMENT_05.pdf PDF
AMENDMENT_04.pdf PDF
NAVSEA_Visitor_Request.xlsx XLSX spreadsheet
AMENDMENT_03.pdf PDF
1._180202_Vol_I_of_XI_Parts_1_thru_3-1395851.pdf.pdf PDF
2._180202_Vol_II_of_XI_Parts_4_and_5-1395851.pdf.pdf PDF
AMENDMENT_02.pdf PDF
3._180202_Vol_III_of_XI_Part_6_Att_A_thru_E_with_photo_edits-1395851.pdf.pdf PDF
AMENDMENT_01.pdf PDF
ATTACHMENT_D_Past_Performance.pdf PDF
PPI_AMENDMENT_01.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNCLASSIFIED

ROUTINE

R 071852Z FEB 18

FM CNO WASHINGTON DC

TO NAVADMIN

INFO CNO WASHINGTON DC

BT

UNCLAS

NAVADMIN 026/18

MSGID/GENADMIN/CNO WASHINGTON DC/N4/FEB//

SUBJ/POLICY AND EXCEPTIONS TO MINIMUM ANTITERRORISM UNIFIED FACILITIES

CRITERIA STANDARDS FOR NAVY PROJECTS//

REF/A/DOC/UFC 4-010-01/01OCT13//

REF/B/DOC/OPNAVINST F3300.53C/26MAY09//

REF/C/DOC/OPNAVINST 5530.14E/20NOV17//

REF/D/DOC/OPNAVINST 11010.20H/24JUN15//

NARR/REF A IS UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR

BUILDINGS, 01 OCTOBER 2013.

REF B IS OPNAVINST F3300.53C, NAVY ANTITERRORISM PROGRAM, 26 MAY 2009.

REF C IS OPNAVINST 5530.14E, NAVY PHYSICAL SECURITY AND LAW ENFORCEMENT

PROGRAM, 20 NOVEMBER 2017.

REF D IS OPNAVINST 11010.20H, NAVY FACILITIES PROJECTS, 24 JUNE 2015.//

POC/R. STILES/CDR/OPNAV N4/ROBERT.STILES@NAVY.MIL/TEL: (703) 695-7204

/DSN: 260-7204//

RMKS/1. In anticipation of and consistent with expected OSD coordinated revisions to reference (a), this message provides amplifying policy and permanent exceptions to specific minimum Department of Defense (DoD) antiterrorism (AT) Unified Facilities Criteria (UFC) standards in reference (a). Exceptions described in this message are effective immediately.

2. Policy. Any Navy project that requires adherence to reference (a) must be planned and designed to the minimum DoD AT standards unless the applicable geographic combatant commander (GCC) has established more stringent measures in higher threat environments.

3. Exceptions. Requests to deviate above or below minimum DoD AT Standards must be submitted and approved by Office of the Chief of Naval Operations Shore Readiness Division (OPNAV N46) per references (b) through (d), unless the deviation is to meet more stringent GCC measures, per paragraph 2, or to enhance protection of defense critical infrastructure (DCI) as identified in the Navy Critical Asset Management System. Deviations for higher GCC or DCI measures may be approved by the installation commanding officer. For all other projects located more than 50 feet on the interior side of a controlled installation perimeter, the following permanent exceptions to reference (a) apply:

a. Standard 1: Site plans and designs do not need to incorporate minimum standoff distances, as defined in reference (a).

b. Standard 2: Unobstructed space must extend out 33 feet from the building. Roadways and parking are allowed within this space.

c. Standard 6: Existing buildings do not need to incorporate progressive collapse resistance, as defined in reference (a).

d. Standard 10: Window systems, to include glazing, framing, connections, and supporting structural elements, do not have to be designed for blast resistance. Neither dynamic analysis nor testing is required.

5/23/2018http://www.public.navy.mil/bupers-npc/reference/messages/Documents/NAVADMINS/N...

Subparagraph B-3.1.7 of reference (a) applies for all exterior glazing.

e. Standard 12: Door assemblies, to include doors, framing, fasteners and anchorage, do not have to be designed or tested for blast resistance. Swinging exterior doors for inhabited areas must open outward.

Exterior doors for inhabited areas that do not swing outward should be designed per subparagraph B-3.3.3 of reference (a) to mitigate the potential to be propelled into inhabited areas. Glazing in and around exterior doors must comply with subparagraph 3d.

4. Implementation of this policy is mandatory for all projects planned for FY20 and beyond. This policy does not relieve commanders of their responsibility to identify and submit deviation requests to incorporate unique AT measures associated with the project based on mission, conditions, and terrorist threat.

5. This policy remains in effect until superseded by a revision of reference (a).

6. Released by VADM D. R. Smith, N4//

BT

#0001

NNNN

UNCLASSIFIED//

5/23/2018http://www.public.navy.mil/bupers-npc/reference/messages/Documents/NAVADMINS/N...

File details come from the government source that posted it.