23B0405 (SDs) ELINs in Excel SS.xlsx
XLSX spreadsheet 184 KB Posted
- Solicitation number
- N4008423B0405
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMD0003.pdf | ||
| AMD0002.pdf | ||
| AMD0001.pdf | ||
| 23B0405B (SDs)_Part7.pdf | ||
| 23B0405B (SDs)_Part6.pdf | ||
| 23B0405B (SDs)_Part9.pdf | ||
| 23B0405B (SDs)_Part5.pdf | ||
| 23B0405B (SDs)_Part10.pdf | ||
| 23B0405B (SDs)_Part1.pdf | ||
| 23B0405B (SDs)_Part2.pdf | ||
| 23B0405A (SF1449).pdf | ||
| 23B0405B (SDs)_Part8.pdf | ||
| 23B0405B (SDs)_Part4.pdf | ||
| 23B0405C (NOTICE).pdf | ||
| 23B0405B (SDs)_Part3.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
SCHEDULE OF PRICE
| NAME OF OFFEROR OR CONTRACTOR: | ||||
| LINE ITEM | ITEM | Q'TY | UNIT | AMOUNT |
| NO. |
| Item 0001 | Recurring, Base Period | 1 | LS | ¥ |
| Provide PM program Services for | ||||
| a period of one year. | ||||
| From 14 Sep 2023 through 13 Sep 2024. |
| Item 0002 | Non-Recurring, Base Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work | (NTE) | |||
| upon receipt of a Task Order | ||||
| From 14 Sep 2023 through 13 Sep 2024. |
| Item 0003 | Recurring, First Option Period | 1 | LS | ¥ |
| Provide PM program Services for | ||||
| a period of one year. | ||||
| From 14 Sep 2024 through 13 Sep 2025. |
| Item 0004 | Non-Recurring, First Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work | (NTE) | |||
| upon receipt of a Task Order | ||||
| From 14 Sep 2024 through 13 Sep 2025. |
| Item 0005 | Recurring, Second Option Period | 1 | LS | ¥ |
| Provide PM program Services for | ||||
| a period of one year. | ||||
| From 14 Sep 2025 through 13 Sep 2026. |
| Item 0006 | Non-Recurring, Second Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work | (NTE) | |||
| upon receipt of a Task Order | ||||
| From 14 Sep 2025 through 13 Sep 2026. |
| Item 0007 | Recurring, Third Option Period | 1 | LS | ¥ |
| Provide PM program Services for | ||||
| a period of one year. | ||||
| From 14 Sep 2026 through 13 Sep 2027. |
| Item 0008 | Non-Recurring, Third Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work | (NTE) | |||
| upon receipt of a Task Order | ||||
| From 14 Sep 2026 through 13 Sep 2027. |
| Item 0009 | Recurring, Fourth Option Period | 1 | LS | ¥ |
| Provide PM program Services for | ||||
| a period of one year. | ||||
| From 14 Sep 2027 through 13 Sep 2028. |
| Item 0010 | Non-Recurring, Fourth Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work | (NTE) | |||
| upon receipt of a Task Order | ||||
| From 14 Sep 2027 through 13 Sep 2028. |
TOTAL: (LINE ITEM 0001 through 0010) ¥ 127.7677 $ - 0
CLIN 9000 Exhibit A (Base Period)
CLIN 9001 Exhibit B (First Option Period)
CLIN 9002 Exhibit C (Second Option Period)
CLIN 9003 Exhibit D (Third Option Period)
CLIN 9004 Exhibit E (Fourth Option Period)
| NOTE: | The number of Placeholders established depends on the maximum number of lines |
| of accounting anticipated on an individual task order. |
Detail line items for task order is located in Attachment J-0200000-07
| CLIN = CONTRACT LINE ITEM |
| LS = LUMP SUM |
| NTE = NOT-TO-EXCEED |
| Q'TY = QUANTITY |
Note: GE was based on the market prices of OEM and Agency and previous bid prices including market increasing prices.
&"Times New Roman,Regular"&8CUI // FEDCON [when filled in] SOURCE SELECTION SENSITIVE--See FAR 2.101 and 3.104 [when filled in]
&"Times New Roman,Regular"SOURCE SELECTION SENSITIVE--See FAR 2.101 and 3.104 [when filled in] B-&P
CUI // FEDCON [when filled in]
BR
| SOLICITATION/CONTRACT # |
| EXHIBIT A - CLIN 9000 |
| Line Item 0001 Recurring - Base Period | ||||||
| Provide Prices For Facility Investment Services - Recurring - In Accordance With Section C, Spec Item 3 | ||||||
| ELINs A001 through A012 | ||||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total | CAC |
| A001 | CNIC Funding Portion | ||||
| A001-001 | NDK-100134 | ||||
| A001-001-01 | Transformer | ||||
| A001-001-01-1 | Monthly PM Work | 12 | TM | ¥ - | ¥ - |
| A001-001-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A001-001-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Transformer Total | ¥ - | ||||
| A001-001-02 | Electric Hot Water Supply System | ||||
| A001-001-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| A001-001-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| NDK-100134 Total | ¥ - | ||||
| A001-002 | YSK-1397 | ||||
| A001-002-01 | Auxiliary Generator System | ||||
| A001-002-01-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-002-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A001-002-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1397 Total | ¥ - | ||||
| A001-003 | YSK-1805 | ||||
| A001-003-01 | Security Camera System | ||||
| A001-003-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-003-01-2 | Service Order | 12 | MO | ¥ - | |
| Security Camera System Total | ¥ - | ||||
| YSK-1805 Total | ¥ - | ||||
| A001-004 | YSK-1922 | ||||
| A001-004-01 | Emergency Light System | ||||
| A001-004-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-004-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-1922 Total | ¥ - | ||||
| A001-005 | YSK-1942 | ||||
| A001-005-01 | Auxiliary Generator System (D825D5A) | ||||
| A001-005-01-1 | Quarterly PM Work | 4 | TM | ¥ - | |
| A001-005-01-2 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-005-01-3 | Annual PM Work | 1 | TM | ¥ - | |
| A001-005-01-4 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System (D825D5A) Total | ¥ - | ||||
| A001-005-02 | Auxiliary Generator System (DQCA1339512) | ||||
| A001-005-02-1 | Quarterly PM Work | 4 | TM | ¥ - | |
| A001-005-02-2 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-005-02-3 | Annual PM Work | 1 | TM | ¥ - | |
| A001-005-02-4 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System (DQCA1339512) Total | ¥ - | ||||
| YSK-1942 Total | ¥ - | ||||
| A001-006 | YSK-1969 | ||||
| A001-006-01 | Electric Card Lock System | ||||
| A001-006-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-006-01-2 | Service Order | 12 | MO | ¥ - | |
| Electric Card Lock System Total | ¥ - | ||||
| A001-006-02 | Security Camera System | ||||
| A001-006-02-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-006-02-2 | Service Order | 12 | MO | ¥ - | |
| Security Camera System Total | ¥ - | ||||
| YSK-1969 Total | ¥ - | ||||
| A001-007 | YSK-2043 | ||||
| A001-007-01 | Emergency Light System | ||||
| A001-007-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-007-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2043 Total | ¥ - | ||||
| A001-008 | YSK-2046 | ||||
| A001-008-01 | Emergency Light System | ||||
| A001-008-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-008-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| A001-008-02 | UPS System | ||||
| A001-008-02-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-008-02-2 | Service Order | 12 | MO | ¥ - | |
| UPS System Total | ¥ - | ||||
| YSK-2046 Total | ¥ - | ||||
| A001-009 | YSK-2067 | ||||
| A001-009-01 | Emergency Light System | ||||
| A001-009-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-009-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2067 Total | ¥ - | ||||
| A001-010 | YSK-2068 | ||||
| A001-010-01 | Emergency Light System | ||||
| A001-010-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-010-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2068 Total | ¥ - | ||||
| A001-011 | YSK-2078 | ||||
| A001-011-01 | Emergency Light System | ||||
| A001-011-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-011-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2078 Total | ¥ - | ||||
| A001-012 | YSK-3014 | ||||
| A001-012-01 | Emergency Light System | ||||
| A001-012-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-012-01-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-3014 Total | ¥ - | ||||
| A001-013 | YSK-3128 | ||||
| A001-013-01 | Auxiliary Generator Systems | ||||
| A001-013-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-013-01-2 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3128 Total | ¥ - | ||||
| A001-014 | YSK-3154 | ||||
| A001-014-01 | Auxiliary Generator System | ||||
| A001-014-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-014-01-2 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3154 Total | ¥ - | ||||
| A001-015 | YSK-3169 | ||||
| A001-015-01 | Auxiliary Generator System | ||||
| A001-015-01-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-015-01-2 | Annual PM Work | 1 | TM | ¥ - | |
| A001-015-01-3 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| A001-015-02 | UPS System | ||||
| A001-015-02-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-015-02-2 | Service Order | 12 | MO | ¥ - | |
| UPS System Total | ¥ - | ||||
| YSK-3169 Total | ¥ - | ||||
| A001-016 | YSK-3365 | ||||
| A001-016-01 | PA Systems | ||||
| A001-016-01-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-016-01-2 | Service Order | 12 | MO | ¥ - | |
| PA Systems Total | ¥ - | ||||
| A001-016-02 | Electric Clock Systems | ||||
| A001-016-02-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-016-02-2 | Service Order | 12 | MO | ¥ - | |
| Electric Clock Systems Total | ¥ - | ||||
| A001-016-03 | Emergency Calling Systems | ||||
| A001-016-03-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-016-03-2 | Service Order | 12 | MO | ¥ - | |
| Emergency Calling Systems Total | ¥ - | ||||
| YSK-3365 Total | ¥ - | ||||
| A001-017 | YSK-3391 | ||||
| A001-017-01 | Auxiliary Generator System | ||||
| A001-017-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-017-01-2 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3391 Total | ¥ - | ||||
| A001-018 | YSK-3816 | ||||
| A001-018-01 | Auxiliary Generator System | ||||
| A001-018-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-018-01-2 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| A001-018-02 | UPS System | ||||
| A001-018-02-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-018-02-2 | Service Order | 12 | MO | ¥ - | |
| UPS System Total | ¥ - | ||||
| YSK-3816 Total | ¥ - | ||||
| A001-019 | YSK-5229 | ||||
| A001-019-01 | Lightning Arrestors and Grounding Devices | ||||
| A001-019-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-019-01-2 | Service Order | 12 | MO | ¥ - | |
| Lightning Arrestors and Grounding Devices Total | ¥ - | ||||
| YSK-5229 Total | ¥ - | ||||
| A001-020 | YSK-F69 | ||||
| A001-020-01 | Auxiliary Generator System | ||||
| A001-020-01-1 | Quarterly PM Work | 4 | TM | ¥ - | |
| A001-020-01-2 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-020-01-3 | Annual PM Work | 1 | TM | ¥ - | |
| A001-020-01-4 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-F69 Total | ¥ - | ||||
| A001-021 | YSK-561 | ||||
| A001-021-01 | Auxiliary Generator System | ||||
| A001-021-01-1 | Quarterly PM Work | 4 | TM | ¥ - | |
| A001-021-01-2 | Annual PM Work | 1 | TM | ¥ - | |
| A001-021-01-3 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-561 Total | ¥ - | ||||
| A001-022 | YSK-4818 | ||||
| A001-022-01 | Permanent Generator System (DCA-60LSIB) | ||||
| A001-022-01-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-022-01-2 | Annual PM Work | 1 | TM | ¥ - | |
| A001-022-01-3 | Service Order | 12 | MO | ¥ - | |
| Permanent Generator System (DCA-60LSIB) Total | ¥ - | ||||
| A001-022-02 | Permanent Generator System (DCA-300SPK3) | ||||
| A001-022-02-1 | Quarterly PM Work | 4 | TM | ¥ - | |
| A001-022-02-2 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-022-02-3 | Annual PM Work | 1 | TM | ¥ - | |
| A001-022-02-4 | Service Order | 12 | MO | ¥ - | |
| Permanent Generator System (DCA-300SPK3) Total | ¥ - | ||||
| YSK-4818 Total | ¥ - | ||||
| A001-023 | YSK-2053 | ||||
| A001-023-01 | Auxiliary Generator System | ||||
| A001-023-01-1 | Annual PM Work | 1 | TM | ¥ - | |
| A001-023-01-2 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-2053 Total | ¥ - | ||||
| A001-024 | YSK-1997 | ||||
| A001-024-01 | Auxiliary Generator System | ||||
| A001-024-01-1 | Quarterly PM Work | 4 | TM | ¥ - | |
| A001-024-01-2 | Annual PM Work | 1 | TM | ¥ - | |
| A001-024-01-3 | Biennial PM Work: | 1 | TM | ¥ - | |
| A001-024-01-4 | Service Order | 12 | MO | ¥ - | |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1997 Total | ¥ - | ||||
| A001-025 | IKE-843 | ||||
| A001-025-01 | UPS System | ||||
| A001-025-01-1 | Simple PM Work | 1 | TM | ¥ - | |
| A001-025-01-2 | Detail PM Work | 1 | TM | ¥ - | |
| A001-025-01-3 | Service Order | 12 | MO | ¥ - | |
| UPS System Total | ¥ - | ||||
| IKE-843 Total | ¥ - | ||||
| A001-026 | Extra High Voltage Receiving & Distribution Systems | ||||
| A001-026-01 | Yokosuka Area | ||||
| A001-026-01-1 | YSK-B94 C-GIS Regular inspection, etc. | 1 | TM | ¥ - | |
| A001-026-01-2 | YSK-1278 Power distribution panel Insulation degradation diagnosis, etc. | 1 | TM | ¥ - | |
| A001-026-01-3 | YSK-1923 Power distribution panel Insulation degradation diagnosis, etc. | 1 | TM | ¥ - | |
| A001-026-01-4 | YSK-1805 Power distribution panel Insulation degradation diagnosis, etc. | 1 | TM | ¥ - | |
| A001-026-01-5 | YSK-1805 FC Facilities On-line Diagnosis | 1 | TM | ¥ - | |
| A001-026-01-6 | YSK-1805 FC Facilities Full-fledged Inspection, Panel Inspection for #4 FC | 1 | TM | ¥ - | |
| A001-026-01-7 | Service Order | 12 | MO | ¥ - | |
| Yokosuka Area Total | ¥ - | ||||
| A001-026-02 | Ikego Area | ||||
| A001-026-02-1 | Preparing Work | 1 | LS | ¥ - | |
| A001-026-02-2 | Service Order | 12 | MO | ¥ - | |
| Ikego Area Total | ¥ - | ||||
| Extra High Voltage Receiving & Distribution Systems Total | ¥ - | ||||
| A001-027 | AZU-8600376 | ||||
| A001-027-01 | Electric Hot Water Supply System | ||||
| A001-027-01-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A001-027-01-2 | Service Order | 12 | MO | ¥ - | |
| AZU-8600376 Total | ¥ - | ||||
| A001-028 | Extra High Voltage Sub-station (Transformer) | ||||
| A001-028-01 | Yokosuka Area | ||||
| A001-028-01-1 | Detail Inspection Work for VCB | 1 | TM | ¥ - | |
| A001-028-01-2 | LBS Replacement Work | 1 | TM | ¥ - | |
| A001-028-01-3 | Service Order | 12 | MO | ¥ - | |
| Extra High Voltage Sub-station (Transformer) Total | ¥ - | ||||
| CNIC Funding Portion Total | ¥ - | ||||
| A002 | USNH Funding Portion | ||||
| A002-001 | YSK-1400 | ||||
| A002-001-01 | Security Camera System | ||||
| A002-001-01-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A002-001-01-2 | Service Order | 12 | MO | ¥ - | |
| Security Camera System Total | ¥ - | ||||
| YSK-1400 Total | ¥ - | ||||
| A002-002 | YSK-1400, 1407, 3201 & 3219 | ||||
| A002-002-02 | Electric Card Lock System | ||||
| A002-002-02-1 | Semiannual PM Work | 2 | TM | ¥ - | |
| A002-002-02-2 | Annual PM Work | 1 | TM | ¥ - | |
| A002-002-02-3 | Service Order | 12 | MO | ¥ - | |
| Electric Card Lock System Total | ¥ - | ||||
| YSK-1400 & 1407 Total | ¥ - | ||||
| USNH Funding Portion Total | ¥ - | ||||
| A003 | DLA ENERGY / FUEL (FLCY) Funding Portion | ||||
| A003-001 | AZU-8600441 | ||||
| A003-001-01 | Auxiliary Generator System | ||||
| A003-001-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A003-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| AZU-8600441 Total | ¥ - | ||||
| A003-002 | AZU-15F | ||||
| A003-002-01 | Auxiliary Generator System (2 Sets of Auxiliary Generator Units) | ||||
| A003-002-01-1 | Annual PM Work w/ Replacement Work | 1 | TM | ¥ - | ¥ - |
| A003-002-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| AZU-15F Total | ¥ - | ||||
| A003-003 | TSU-4200200 | ||||
| A003-003-01 | Auxiliary Generator System | ||||
| A003-003-01-1 | Annual PM Work w/ Replacement Work | 1 | TM | ¥ - | ¥ - |
| A003-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| TSU-4200200 Total | ¥ - | ||||
| A003-004 | TSU-4300394 | ||||
| A003-004-01 | Auxiliary Generator System | ||||
| A003-004-01-1 | Annual PM Work w/ Replacement Work | 1 | TM | ¥ - | ¥ - |
| A003-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| TSU-4300394 Total | ¥ - | ||||
| DLA ENERGY / FUEL (FLCY) Funding Portion Total | ¥ - | ||||
| A004 | SRF Funding Portion | ||||
| A004-001 | YSK-2046 | ||||
| A004-001-01 | Access Control Systems System | ||||
| A004-001-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| A004-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Access Control Systems Total | ¥ - | ||||
| YSK-2046 Total | ¥ - | ||||
| A004-002 | YSK-B12 | ||||
| A004-002-01 | Power Receiving System of Land Cranes LC-47 & 48 | ||||
| A004-002-01-1 | Annual PM Work (Type B) | 1 | TM | ¥ - | ¥ - |
| A004-002-01-2 | Initial Repair Work | 1 | TM | ¥ - | ¥ - |
| A004-002-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Power Receiving System of Land Cranes Total | ¥ - | ||||
| YSK-B12 Total | ¥ - | ||||
| SRF Funding Portion Total | ¥ - | ||||
| A005 | DODDS Funding Portion | ||||
| A005-001 | YSK-1292 (Sullivan School) | ||||
| A005-001-01 | LED Massage Board System | ||||
| A005-001-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| LED Massage Board System Total | ¥ - | ||||
| YSK-1292 Total | ¥ - | ||||
| A005-002 | YSK-1901 (Kinnick High School) | ||||
| A005-002-01 | Electric Card Lock System | ||||
| A005-002-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-002-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Card Lock System Total | ¥ - | ||||
| A005-002-02 | LED Massage Board System | ||||
| A005-002-02-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-002-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| LED Massage Board System Total | ¥ - | ||||
| YSK-1901 Total | ¥ - | ||||
| A005-003 | IKE-774 | ||||
| A005-003-01 | Security Camera System | ||||
| A005-003-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| IKE-774 Total | ¥ - | ||||
| A005-004 | IKE-824S | ||||
| A005-004-01 | Security Camera System | ||||
| A005-004-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| A005-004-02 | PA Systems | ||||
| A005-004-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| A005-004-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| PA Systems Total | ¥ - | ||||
| A005-004-03 | Electric Clock Systems | ||||
| A005-004-03-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| A005-004-03-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Clock Systems Total | ¥ - | ||||
| A005-004-04 | Emergency Calling Systems | ||||
| A005-004-04-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-004-04-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Calling Systems Total | ¥ - | ||||
| A005-004-05 | Interphone Systems | ||||
| A005-004-05-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-004-05-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Interphone Systems Total | ¥ - | ||||
| A005-004-06 | LED Massage Board System | ||||
| A005-004-06-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-004-06-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| LED Massage Board System Total | ¥ - | ||||
| A005-004-07 | Eco Hot Water Supply System | ||||
| A005-004-07-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| A005-004-07-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A005-004-07-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| IKE-824S Total | ¥ - | ||||
| A005-005 | IKE-827 | ||||
| A005-005-01 | Electric Water Heater Tank System | ||||
| A005-005-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| A005-005-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| IKE-827 Total | ¥ - | ||||
| DODDS Funding Portion Total | ¥ - | ||||
| A006 | HOUSING Funding Portion | ||||
| A006-001 | YSK-3849 (SHOBU) | ||||
| A006-001-01 | Auxiliary Generator System | ||||
| A006-001-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A006-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3849 Total | ¥ - | ||||
| A006-002 | YSK-3853 (TSUBAKI) | ||||
| A006-002-01 | Auxiliary Generator System | ||||
| A006-002-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A006-002-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3853 Total | ¥ - | ||||
| A006-003 | YSK- 4401 (BARA) | ||||
| A006-003-01 | Auxiliary Generator System | ||||
| A006-003-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A006-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK- 4401 Total | ¥ - | ||||
| A006-004 | YSK- 4402 (UME) | ||||
| A006-004-01 | Auxiliary Generator System | ||||
| A006-004-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A006-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK- 4402 Total | ¥ - | ||||
| HOUSING Funding Portion Total | ¥ - | ||||
| A007 | DLA DISTRIBUTION | ||||
| A007-001 | YSK-1907 | ||||
| A007-001-01 | Auxiliary Generator System | ||||
| A007-001-01-1 | Dummy Load Test | 1 | TM | ¥ - | ¥ - |
| A007-001-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| A007-001-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1907 Total | ¥ - | ||||
| DLA DISTRO / DDYJ Portion Total | ¥ - |
TOTAL RECURRING LINE ITEMS ¥ -
MO=Month, TM=Time
&"Times New Roman,Regular"&K000000CUI // FEDCON SOURCE SELECTION SENSITIVE--See FAR 2.101 and 3.104&U
ATTACHMENT J-0200000-07
EXHIBIT LINE ITEM NUMBERS
&"Times New Roman,Regular"SOURCE SELECTION SENSITIVE--See FAR 2.101 and 3.104 Page &P of &N
CUI // FEDCON
SECTION J
EXHIBIT A
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6'
Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Barbwire Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Ornamental Steel Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Wood Fence.
PROVIDE A UNIT PRICE FOR THE REMOVAL AND DISPOSAL OF FENCE COMPLETE, FENCE POSTS, BARBWIRE, BARBED TAPE.
IN ACCORDANCE WITH SECTION C, C.10.1.l
ELIN A001EW through A001FI
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence.
Including Fabric, Posts, Gates, Rails, Tension Wire, Barbwire/Barbed Tape.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence Gates including tracks (not posts).
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Ornamental Steel Fence. Including Posts and Gates
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Wood Fence. Including Posts and Gates.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Barbwire Fence. Including Posts and all wire.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to Provide Removal Service for Fence Posts. Post Cut-off Flush.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to Provide Removal Service for Fence Posts. Driven Post.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Posts Set in Concrete/Asphalt.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Square Foot to Patch and Refinish Concrete or Asphalt Surface.
Surface Depth to Match Surrounding.
Unit Price Each to Remove and Dispose of or Save and Store (for reuse) Barbwire Single Arm Support.
Unit Price Each to remove and Dispose of or Save and Store (for reuse) Barbwire Double (V) Arm Support.
Lump Sum Price for the recycling of removed materials. Based on a Percentage Added to Removal Item Ordered
SECTION J
EXHIBIT A
Lump Sum Price for the Recycling of Removed Materials. Based on a Percentage Added to Removal Item Ordered, ELIN A001EK to A001EW. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
PROVIDE A UNIT PRICE TO PERFORM EXPEDITED SERVICES.
IN ACCORDANCE WITH SECTION C, C.10.2
ELIN A001FJ
Lump Sum Price for Expedited Maintenance and Repair Services. Based on a Percentage Added to Task Order Total. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
SECTION J
EXHIBIT A
PROVIDE A UNIT PRICE FOR THE RENTAL OF TEMPORARY CHAIN LINK FENCE.
IN ACCORDANCE WITH SECTION C, C.10.3
ELIN A001FK THROUGH A001FP
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
6' Fence Height Driven Posts
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
12' Panel, 6' Height
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
12' Panel, 6' Height, Free-Standing
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
With Barbwire, 7' Fence Height
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
12' Panel, With Barbwire, 7' Height
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
12' Panel, With Barbwire, 7' Height, Free-Standing
1R
| SOLICITATION/CONTRACT # |
| EXHIBIT B - CLIN 9001 |
| Line Item 0003 Recurring - First Option Period | ||||||
| Provide Prices For Facility Investment Services - Recurring - In Accordance With Section C, Spec Item 3 | ||||||
| ELINs B001 through B012 | ||||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total | CAC |
| B001 | CNIC Funding Portion | ||||
| B001-001 | NDK-100134 | ||||
| B001-001-01 | Transformer | ||||
| B001-001-01-1 | Monthly PM Work | 12 | TM | ¥ - | ¥ - |
| B001-001-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-001-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Transformer Total | ¥ - | ||||
| B001-001-02 | Electric Hot Water Supply System | ||||
| B001-001-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-001-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| NDK-100134 Total | ¥ - | ||||
| B001-002 | YSK-1397 | ||||
| B001-002-01 | Auxiliary Generator System | ||||
| B001-002-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-002-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-002-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1397 Total | ¥ - | ||||
| B001-003 | YSK-1805 | ||||
| B001-003-01 | Security Camera System | ||||
| B001-003-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-003-01-2 | Scheduled Replacement Work | 1 | TM | ¥ - | ¥ - |
| B001-003-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| YSK-1805 Total | ¥ - | ||||
| B001-004 | YSK-1922 | ||||
| B001-004-01 | Emergency Light System | ||||
| B001-004-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-1922 Total | ¥ - | ||||
| B001-005 | YSK-1942 | ||||
| B001-005-01 | Auxiliary Generator System (D825D5A) | ||||
| B001-005-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| B001-005-01-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-005-01-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-005-01-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System (D825D5A) Total | ¥ - | ||||
| B001-005-02 | Auxiliary Generator System (DQCA1339512) | ||||
| B001-005-02-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| B001-005-02-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-005-02-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-005-02-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System (DQCA1339512) Total | ¥ - | ||||
| YSK-1942 Total | ¥ - | ||||
| B001-006 | YSK-1969 | ||||
| B001-006-01 | Electric Card Lock System | ||||
| B001-006-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-006-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Card Lock System Total | ¥ - | ||||
| B001-006-02 | Security Camera System | ||||
| B001-006-02-1 | Semiannual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-006-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| YSK-1969 Total | ¥ - | ||||
| B001-007 | YSK-2043 | ||||
| B001-007-01 | Emergency Light System | ||||
| B001-007-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-007-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2043 Total | ¥ - | ||||
| B001-008 | YSK-2046 | ||||
| B001-008-01 | Emergency Light System | ||||
| B001-008-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-008-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| B001-008-02 | UPS System | ||||
| B001-008-02-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-008-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| YSK-2046 Total | ¥ - | ||||
| B001-009 | YSK-2067 | ||||
| B001-009-01 | Emergency Light System | ||||
| B001-009-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-009-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2067 Total | ¥ - | ||||
| B001-010 | YSK-2068 | ||||
| B001-010-01 | Emergency Light System | ||||
| B001-010-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-010-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2068 Total | ¥ - | ||||
| B001-011 | YSK-2078 | ||||
| B001-011-01 | Emergency Light System | ||||
| B001-011-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-011-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2078 Total | ¥ - | ||||
| B001-012 | YSK-3014 | ||||
| B001-012-01 | Emergency Light System | ||||
| B001-012-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-012-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-3014 Total | ¥ - | ||||
| B001-013 | YSK-3128 | ||||
| B001-013-01 | Auxiliary Generator Systems | ||||
| B001-013-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-013-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3128 Total | ¥ - | ||||
| B001-014 | YSK-3154 | ||||
| B001-014-01 | Auxiliary Generator System | ||||
| B001-014-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-014-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3154 Total | ¥ - | ||||
| B001-015 | YSK-3169 | ||||
| B001-015-01 | Auxiliary Generator System | ||||
| B001-015-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-015-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-015-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| B001-015-02 | UPS System | ||||
| B001-015-02-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-015-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| YSK-3169 Total | ¥ - | ||||
| B001-016 | YSK-3365 | ||||
| B001-016-01 | PA Systems | ||||
| B001-016-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-016-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| PA Systems Total | ¥ - | ||||
| B001-016-02 | Electric Clock Systems | ||||
| B001-016-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-016-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Clock Systems Total | ¥ - | ||||
| B001-016-03 | Emergency Calling Systems | ||||
| B001-016-03-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-016-03-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Calling Systems Total | ¥ - | ||||
| YSK-3365 Total | ¥ - | ||||
| B001-017 | YSK-3391 | ||||
| B001-017-01 | Auxiliary Generator System | ||||
| B001-017-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-017-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3391 Total | ¥ - | ||||
| B001-018 | YSK-3816 | ||||
| B001-018-01 | Auxiliary Generator System | ||||
| B001-018-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-018-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| B001-018-02 | UPS System | ||||
| B001-018-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-018-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| YSK-3816 Total | ¥ - | ||||
| B001-019 | YSK-5229 | ||||
| B001-019-01 | Lightning Arrestors and Grounding Devices | ||||
| B001-019-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-019-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Lightning Arrestors and Grounding Devices Total | ¥ - | ||||
| YSK-5229 Total | ¥ - | ||||
| B001-020 | YSK-F69 | ||||
| B001-020-01 | Auxiliary Generator System | ||||
| B001-020-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| B001-020-01-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-020-01-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-020-01-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-F69 Total | ¥ - | ||||
| B001-021 | YSK-561 | ||||
| B001-021-01 | Auxiliary Generator System | ||||
| B001-021-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| B001-021-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-021-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-561 Total | ¥ - | ||||
| B001-022 | YSK-4818 | ||||
| B001-022-01 | Permanent Generator System (DCA-60LSIB) | ||||
| B001-022-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-022-01-2 | Annual PM Work including Actual Facility Load Test, 4TM | 1 | TM | ¥ - | ¥ - |
| B001-022-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Permanent Generator System (DCA-60LSIB) Total | ¥ - | ||||
| B001-022-02 | Permanent Generator System (DCA-300SPK3) | ||||
| B001-022-02-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| B001-022-02-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-022-02-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-022-02-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Permanent Generator System (DCA-300SPK3) Total | ¥ - | ||||
| YSK-4818 Total | ¥ - | ||||
| B001-023 | YSK-2053 | ||||
| B001-023-01 | Auxiliary Generator System | ||||
| B001-023-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-023-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-2053 Total | ¥ - | ||||
| B001-024 | YSK-1997 | ||||
| B001-024-01 | Auxiliary Generator System | ||||
| B001-024-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| B001-024-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B001-024-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1997 Total | ¥ - | ||||
| B001-025 | IKE-843 | ||||
| B001-025-01 | UPS System | ||||
| B001-025-01-1 | Simple PM Work | 1 | TM | ¥ - | ¥ - |
| B001-025-01-2 | Detail PM Work | 1 | TM | ¥ - | ¥ - |
| B001-025-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| IKE-843 Total | ¥ - | ||||
| B001-026 | Extra High Voltage Receiving & Distribution Systems | ||||
| B001-026-01 | Yokosuka Area | ||||
| B001-026-01-1 | YSK-B94 C-GIS Regular Inspection, etc. | 1 | TM | ¥ - | ¥ - |
| B001-026-01-2 | YSK-1278 Power Distribution Panel Insulation Degradation Diagnosis, etc | 1 | TM | ¥ - | ¥ - |
| B001-026-01-3 | YSK-1923 Power Distribution Panel Insulation Degradation Diagnosis, etc | 1 | TM | ¥ - | ¥ - |
| B001-026-01-4 | YSK-1805 Power Distribution Panel Insulation Degradation Diagnosis, etc | 1 | TM | ¥ - | ¥ - |
| B001-026-01-5 | YSK-1805 FC Facilities On-line Diagnosis | 1 | TM | ¥ - | ¥ - |
| B001-026-01-6 | YSK-1805 FC Facilities Full-fledged Inspection, Panel Inspection for #1FC | 1 | TM | ¥ - | ¥ - |
| B001-026-01-7 | Service Order | 12 | MO | ¥ - | ¥ - |
| Yokosuka Area Total | ¥ - | ||||
| B001-026-02 | Ikego Area | ||||
| B001-026-02-1 | Replacement Work | 1 | TM | ¥ - | ¥ - |
| B001-026-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Ikego Area Total | ¥ - | ||||
| Extra High Voltage Receiving & Distribution Systems Total | ¥ - | ||||
| B001-027 | AZU-8600376 | ||||
| B001-027-01 | Electric Hot Water Supply System | ||||
| B001-027-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B001-027-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| AZU-8600376 Total | ¥ - | ||||
| CNIC Funding Portion Total | ¥ - | ||||
| B002 | USNH Funding Portion | ||||
| B002-001 | YSK-1400 | ||||
| B002-001-01 | Security Camera System | ||||
| B002-001-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B002-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| YSK-1400 Total | ¥ - | ||||
| B002-002 | YSK-1400, 1407, 3201 & 3219 | ||||
| B002-002-02 | Electric Card Lock System | ||||
| B002-002-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B002-002-02-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B002-002-02-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Card Lock System Total | ¥ - | ||||
| YSK-1400 & 1407 Total | ¥ - | ||||
| USNH Funding Portion Total | ¥ - | ||||
| B003 | DLA ENERGY / FUEL (FLCY) Funding Portion | ||||
| B003-001 | AZU-8600441 | ||||
| B003-001-01 | Auxiliary Generator System | ||||
| B003-001-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B003-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| AZU-8600441 Total | ¥ - | ||||
| B003-002 | AZU-15F | ||||
| B003-002-01 | Auxiliary Generator System (2 Sets of Auxiliary Generator Units) | ||||
| B003-002-01-1 | Annual PM Work w/ Replacement Work | 1 | TM | ¥ - | ¥ - |
| B003-002-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| AZU-15F Total | ¥ - | ||||
| B003-003 | TSU-4200200 | ||||
| B003-003-01 | Auxiliary Generator System | ||||
| B003-003-01-1 | Annual PM Work w/ Replacement Work | 1 | TM | ¥ - | ¥ - |
| B003-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| TSU-4200200 Total | ¥ - | ||||
| B003-004 | TSU-4300394 | ||||
| B003-004-01 | Auxiliary Generator System | ||||
| B003-004-01-1 | Annual PM Work w/ Replacement Work | 1 | TM | ¥ - | ¥ - |
| B003-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| TSU-4300394 Total | ¥ - | ||||
| DLA ENERGY / FUEL (FLCY) Funding Portion Total | ¥ - | ||||
| B004 | SRF Funding Portion | ||||
| B004-001 | YSK-2046 | ||||
| B004-001-01 | Access Control Systems System | ||||
| B004-001-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B004-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Access Control Systems Total | ¥ - | ||||
| YSK-2046 Total | ¥ - | ||||
| B004-002 | YSK-B12 | ||||
| B004-002-01 | Power Receiving System of Land Cranes LC-47 & 48 | ||||
| B004-002-01-1 | Annual PM Work (Type B) | 1 | TM | ¥ - | ¥ - |
| B004-002-01-2 | Once Three (3) Years PM Work (Type C) | 1 | TM | ¥ - | ¥ - |
| B004-002-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Power Receiving System of Land Cranes Total | ¥ - | ||||
| YSK-B12 Total | ¥ - | ||||
| SRF Funding Portion Total | ¥ - | ||||
| B005 | DODDS Funding Portion | ||||
| B005-001 | YSK-1292 (Sullivan School) | ||||
| B005-001-01 | LED Massage Board System | ||||
| B005-001-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| LED Massage Board System Total | ¥ - | ||||
| YSK-1292 Total | ¥ - | ||||
| B005-002 | YSK-1901 (Kinnick High School) | ||||
| B005-002-01 | Electric Card Lock System | ||||
| B005-002-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-002-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Card Lock System Total | ¥ - | ||||
| B005-002-02 | LED Massage Board System | ||||
| B005-002-02-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-002-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| LED Massage Board System Total | ¥ - | ||||
| YSK-1901 Total | ¥ - | ||||
| B005-003 | IKE-774 | ||||
| B005-003-01 | Security Camera System | ||||
| B005-003-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| IKE-774 Total | ¥ - | ||||
| B005-004 | IKE-824S | ||||
| B005-004-01 | Security Camera System | ||||
| B005-004-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| B005-004-02 | PA Systems | ||||
| B005-004-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B005-004-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| PA Systems Total | ¥ - | ||||
| B005-004-03 | Electric Clock Systems | ||||
| B005-004-03-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B005-004-03-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Clock Systems Total | ¥ - | ||||
| B005-004-04 | Emergency Calling Systems | ||||
| B005-004-04-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-004-04-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Calling Systems Total | ¥ - | ||||
| B005-004-05 | Interphone Systems | ||||
| B005-004-05-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-004-05-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Interphone Systems Total | ¥ - | ||||
| B005-004-06 | LED Massage Board System | ||||
| B005-004-06-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-004-06-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| LED Massage Board System Total | ¥ - | ||||
| B005-004-07 | Eco Hot Water Supply System | ||||
| B005-004-07-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B005-004-07-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B005-004-07-3 | Scheduled Repair Work | 1 | TM | ¥ - | ¥ - |
| B005-004-07-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| IKE-824S Total | ¥ - | ||||
| B005-005 | IKE-827 | ||||
| B005-005-01 | Electric Water Heater Tank System | ||||
| B005-005-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| B005-005-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| IKE-827 Total | ¥ - | ||||
| DODDS Funding Portion Total | ¥ - | ||||
| B006 | HOUSING Funding Portion | ||||
| B006-001 | YSK-3849 (SHOBU) | ||||
| B006-001-01 | Auxiliary Generator System | ||||
| B006-001-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B006-001-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3849 Total | ¥ - | ||||
| B006-002 | YSK-3853 (TSUBAKI) | ||||
| B006-002-01 | Auxiliary Generator System | ||||
| B006-002-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B006-002-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3853 Total | ¥ - | ||||
| B006-003 | YSK- 4401 (BARA) | ||||
| B006-003-01 | Auxiliary Generator System | ||||
| B006-003-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B006-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK- 4401 Total | ¥ - | ||||
| B006-004 | YSK- 4402 (UME) | ||||
| B006-004-01 | Auxiliary Generator System | ||||
| B006-004-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B006-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK- 4402 Total | ¥ - | ||||
| HOUSING Funding Portion Total | ¥ - | ||||
| B007 | DLA DISTRIBUTION | ||||
| B007-001 | YSK-1907 | ||||
| B007-001-01 | Auxiliary Generator System | ||||
| B007-001-01-1 | Dummy Load Test | 1 | TM | ¥ - | ¥ - |
| B007-001-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| B007-001-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1907 Total | ¥ - | ||||
| DLA DISTRO / DDYJ Portion Total | ¥ - |
TOTAL RECURRING LINE ITEMS ¥ -
MO=Month, TM=Time
ATTACHMENT J-0200000-07
EXHIBIT LINE ITEM NUMBERS
&"Times New Roman,Regular"SOURCE SELECTION SENSITIVE--See FAR 2.101 and 3.104 Page &P of &N
CUI // FEDCON
SECTION J
EXHIBIT A
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Ornamental Steel Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
PROVIDE A UNIT PRICE FOR THE REMOVAL AND DISPOSAL OF FENCE COMPLETE, FENCE POSTS, BARBWIRE, BARBED TAPE.
ELIN A001EW through A001FI
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence Gates including tracks (not posts).
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Ornamental Steel Fence. Including Posts and Gates
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Removal Service for Barbwire Fence. Including Posts and all wire.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Each to remove and Dispose of or Save and Store (for reuse) Barbwire Double (V) Arm Support.
Lump Sum Price for the recycling of removed materials. Based on a Percentage Added to Removal Item Ordered
Lump Sum Price for the Recycling of Removed Materials. Based on a Percentage Added to Removal Item Ordered, ELIN A001EK to A001EW. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
Lump Sum Price for Expedited Maintenance and Repair Services. Based on a Percentage Added to Task Order Total. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
SECTION J
EXHIBIT A
PROVIDE A UNIT PRICE FOR THE RENTAL OF TEMPORARY CHAIN LINK FENCE.
IN ACCORDANCE WITH SECTION C, C.10.3
ELIN A001FK THROUGH A001FP
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
2R
| SOLICITATION/CONTRACT # |
| EXHIBIT B - CLIN 9002 |
| Line Item 0005 Recurring - Second Option Period | ||||||
| Provide Prices For Facility Investment Services - Recurring - In Accordance With Section C, Spec Item 3 | ||||||
| ELINs C001 through C012 | ||||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total | CAC |
| C001 | CNIC Funding Portion | ||||
| C001-001 | NDK-100134 | ||||
| C001-001-01 | Transformer | ||||
| C001-001-01-1 | Monthly PM Work | 12 | TM | ¥ - | ¥ - |
| C001-001-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-001-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Transformer Total | ¥ - | ||||
| C001-001-02 | Electric Hot Water Supply System | ||||
| C001-001-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-001-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Hot Water Supply System Total | ¥ - | ||||
| NDK-100134 Total | ¥ - | ||||
| C001-002 | YSK-1397 | ||||
| C001-002-01 | Auxiliary Generator System | ||||
| C001-002-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-002-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-002-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1397 Total | ¥ - | ||||
| C001-003 | YSK-1805 | ||||
| C001-003-01 | Security Camera System | ||||
| C001-003-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-003-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| YSK-1805 Total | ¥ - | ||||
| C001-004 | YSK-1922 | ||||
| C001-004-01 | Emergency Light System | ||||
| C001-004-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-004-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-1922 Total | ¥ - | ||||
| C001-005 | YSK-1942 | ||||
| C001-005-01 | Auxiliary Generator System (D825D5A) | ||||
| C001-005-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| C001-005-01-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-005-01-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-005-01-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System (D825D5A) Total | ¥ - | ||||
| C001-005-02 | Auxiliary Generator System (DQCA1339512) | ||||
| C001-005-02-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| C001-005-02-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-005-02-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-005-02-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System (DQCA1339512) Total | ¥ - | ||||
| YSK-1942 Total | ¥ - | ||||
| C001-006 | YSK-1969 | ||||
| C001-006-01 | Electric Card Lock System | ||||
| C001-006-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-006-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Card Lock System Total | ¥ - | ||||
| C001-006-02 | Security Camera System | ||||
| C001-006-02-1 | Semiannual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-006-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Security Camera System Total | ¥ - | ||||
| YSK-1969 Total | ¥ - | ||||
| C001-007 | YSK-2043 | ||||
| C001-007-01 | Emergency Light System | ||||
| C001-007-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-007-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2043 Total | ¥ - | ||||
| C001-008 | YSK-2046 | ||||
| C001-008-01 | Emergency Light System | ||||
| C001-008-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-008-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| C001-008-02 | UPS System | ||||
| C001-008-02-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-008-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| YSK-2046 Total | ¥ - | ||||
| C001-009 | YSK-2067 | ||||
| C001-009-01 | Emergency Light System | ||||
| C001-009-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-009-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2067 Total | ¥ - | ||||
| C001-010 | YSK-2068 | ||||
| C001-010-01 | Emergency Light System | ||||
| C001-010-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-010-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2068 Total | ¥ - | ||||
| C001-011 | YSK-2078 | ||||
| C001-011-01 | Emergency Light System | ||||
| C001-011-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-011-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-2078 Total | ¥ - | ||||
| C001-012 | YSK-3014 | ||||
| C001-012-01 | Emergency Light System | ||||
| C001-012-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-012-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Light Systems Total | ¥ - | ||||
| YSK-3014 Total | ¥ - | ||||
| C001-013 | YSK-3128 | ||||
| C001-013-01 | Auxiliary Generator Systems | ||||
| C001-013-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-013-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3128 Total | ¥ - | ||||
| C001-014 | YSK-3154 | ||||
| C001-014-01 | Auxiliary Generator System | ||||
| C001-014-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-014-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3154 Total | ¥ - | ||||
| C001-015 | YSK-3169 | ||||
| C001-015-01 | Auxiliary Generator System | ||||
| C001-015-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-015-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-015-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| C001-015-02 | UPS System | ||||
| C001-015-02-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-015-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| YSK-3169 Total | ¥ - | ||||
| C001-016 | YSK-3365 | ||||
| C001-016-01 | PA Systems | ||||
| C001-016-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-016-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| PA Systems Total | ¥ - | ||||
| C001-016-02 | Electric Clock Systems | ||||
| C001-016-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-016-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Electric Clock Systems Total | ¥ - | ||||
| C001-016-03 | Emergency Calling Systems | ||||
| C001-016-03-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-016-03-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Emergency Calling Systems Total | ¥ - | ||||
| YSK-3365 Total | ¥ - | ||||
| C001-017 | YSK-3391 | ||||
| C001-017-01 | Auxiliary Generator System | ||||
| C001-017-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-017-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-3391 Total | ¥ - | ||||
| C001-018 | YSK-3816 | ||||
| C001-018-01 | Auxiliary Generator System | ||||
| C001-018-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-018-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| C001-018-02 | UPS System | ||||
| C001-018-02-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-018-02-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| YSK-3816 Total | ¥ - | ||||
| C001-019 | YSK-5229 | ||||
| C001-019-01 | Lightning Arrestors and Grounding Devices | ||||
| C001-019-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-019-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Lightning Arrestors and Grounding Devices Total | ¥ - | ||||
| YSK-5229 Total | ¥ - | ||||
| C001-020 | YSK-F69 | ||||
| C001-020-01 | Auxiliary Generator System | ||||
| C001-020-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| C001-020-01-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-020-01-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-020-01-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-F69 Total | ¥ - | ||||
| C001-021 | YSK-561 | ||||
| C001-021-01 | Auxiliary Generator System | ||||
| C001-021-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| C001-021-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-021-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-561 Total | ¥ - | ||||
| C001-022 | YSK-4818 | ||||
| C001-022-01 | Permanent Generator System (DCA-60LSIB) | ||||
| C001-022-01-1 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-022-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-022-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| Permanent Generator System (DCA-60LSIB) Total | ¥ - | ||||
| C001-022-02 | Permanent Generator System (DCA-300SPK3) | ||||
| C001-022-02-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| C001-022-02-2 | Semiannual PM Work | 2 | TM | ¥ - | ¥ - |
| C001-022-02-3 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-022-02-4 | Service Order | 12 | MO | ¥ - | ¥ - |
| Permanent Generator System (DCA-300SPK3) Total | ¥ - | ||||
| YSK-4818 Total | ¥ - | ||||
| C001-023 | YSK-2053 | ||||
| C001-023-01 | Auxiliary Generator System | ||||
| C001-023-01-1 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-023-01-2 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-2053 Total | ¥ - | ||||
| C001-024 | YSK-1997 | ||||
| C001-024-01 | Auxiliary Generator System | ||||
| C001-024-01-1 | Quarterly PM Work | 4 | TM | ¥ - | ¥ - |
| C001-024-01-2 | Annual PM Work | 1 | TM | ¥ - | ¥ - |
| C001-024-01-3 | Biennial PM Work | 1 | TM | ¥ - | ¥ - |
| C001-024-01-4 | Once Three (3) Years PM Work | 1 | TM | ¥ - | ¥ - |
| C001-024-01-5 | Service Order | 12 | MO | ¥ - | ¥ - |
| Auxiliary Generator System Total | ¥ - | ||||
| YSK-1997 Total | ¥ - | ||||
| C001-025 | IKE-843 | ||||
| C001-025-01 | UPS System | ||||
| C001-025-01-1 | Simple PM Work | 1 | TM | ¥ - | ¥ - |
| C001-025-01-2 | Detail PM Work | 1 | TM | ¥ - | ¥ - |
| C001-025-01-3 | Service Order | 12 | MO | ¥ - | ¥ - |
| UPS System Total | ¥ - | ||||
| IKE-843 Total | ¥ - | ||||
| C001-026 | Extra High Voltage Receiving & Distribution Systems | ||||
| C001-026-01 | Yokosuka Area | ||||
| C001-026-01-1 | YSK-B94 C-GIS Regular Inspection, etc. | 1 | TM | ¥ - | ¥ - |
| C001-026-01-2 | YSK-1278 Power Distribution Panel Insulation Degradation Diagnosis, etc | 1 | TM | ¥ - | ¥ - |
| C001-026-01-3 | YSK-1923 Power Distribution Panel Insulation Degradation Diagnosis, etc | 1 | TM | ¥ - | ¥ - |
| C001-026-01-4 | YSK-1805 Power Distribution Panel Insulation Degradation Diagnosis, etc | 1 | TM | ¥ - | ¥ - |
| C001-026-01-5 | YSK-1278 GCB Regular Inspection | 1 | TM | ¥ - | ¥ - |
| C001-026-01-6 | YSK-1923 GCB Regular Inspection | 1 | TM | ¥ - | ¥ - |
| C001-026-01-7 | YSK-1805 FC Facilities On-line Diagnosis | 1 | TM | ¥ - | ¥ - |
This is the start of the file's text. The full file is on GovTribe.