BLDG-P719-1590908-CS511 - OPTION 3.pdf

PDF 531 KB Posted

Attached to
P719 DBB Wargaming Center, Quantico, VA Federal contract opportunity
Solicitation number
N4008020R5249
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This solicitation is for a military construction project to design and build a new wargaming center at Marine Corps Base Quantico in Virginia. Key details include constructing a new two-story, 100,443 square foot academic instruction facility in a Georgian architectural style to support wargaming functions. An additional 132,116 square foot multi-story precast concrete parking structure will be built with auger cast pile foundations and floors. A 1,650 square foot Area Distribution Node is also part of the project to provide voice, video, and data communication capabilities. The solicitation is unrestricted with full and open competition and will use best value source selection as the award methodology. The Navy is listed as the contracting agency with an estimated construction value between $100-250 million.

View the file

Other files for this federal contract opportunity

Other files attached to P719 DBB Wargaming Center, Quantico, VA, newest first.
File Type Posted
P719 AMENDMENT 0015.pdf PDF
26 26 00.pdf PDF
P719 Second Floor RCPs_rev 20 1218.pdf PDF
BLDG-P719-1590908-Response to RFI 285.pdf PDF
BLDG-P719-1590908-Response to RFI 289.pdf PDF
05 52 00.pdf PDF
P719 AMENDMENT 0014.pdf PDF
BLDG-P719-1590908-CS512 - OPTION 2.pdf PDF
REVISED 32 31 13.53.pdf PDF
08 56 46.20 20.pdf PDF
P719 Wargaming Center Price Schedule dated 18 December 2020.docx DOCX document
P719 AMENDMENT 0013.pdf PDF
P719 AMENDMENT 0012.pdf PDF
07 60 00.pdf PDF
A-416 - ENLARGED AUDITORIUM PLAN_WOOD WALL CAP.pdf PDF
P719 Wargaming Center Price Schedule dated 14 December 2020.docx DOCX document
32 31 13.53 - without redlines.pdf PDF
31 21 13.pdf PDF
08 33 23.pdf PDF
10 22 13.pdf PDF
P719 AMENDMENT 0011.pdf PDF
P719 AMENDMENT 0010.pdf PDF
P719 AMENDMENT 0009.pdf PDF
32 31 13.53.pdf PDF
P719 AMENDMENT 0008.pdf PDF
Checklist for Reviewing Subk Plans.pdf PDF
P719 AMENDMENT 0007.pdf PDF
P719 AMENDMENT 0006.pdf PDF
P719 Site Visit Attendance Sheet.PDF PDF
P719 AMENDMENT 0005.pdf PDF
P719 AMENDMENT 0004.pdf PDF
P719 AMENDMENT 0002.pdf PDF
P719 AMENDMENT 0001.pdf PDF
ATTACHMENT C - Construction Experience Project Data Sheet.doc DOC document
ATTACHMENT D - Past Performance Questionnaire.doc DOC document
SOLICTITATION N4008020R5249 - P719 WARGAMING CENTER MCBQ.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A1 PEDESTRIAN TURNSTILE

NTS

COMPACTED SUBGRADE

PROVIDE 8" CONC SLAB W/ #4 REINFORCING

BARS @ 12" OC, EACH WAY, MOS (TYP)

10" AGGREGATE BASE COURSE

4"

T

Y

P

S

C

H

E

D

U

L

E

P

I

P

E

TURNSTILE NOTES:

1. PROVIDE TURNSTILE COMPOSED OF CARBON STEEL. ALL MATERIALS MUST BE

HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123.

2. PROVIDE TURNSTILE HAVING BI-DIRECTIONAL CONTROLS: IN THE CASE OF A

POWER FAILURE, OUTBOUND TRAFFIC MUST BE SET TO "FAIL SAFE"; THE

INBOUND TRAFFIC WILL HAVE A "FAIL LOCK" MECHANISM (UNLESS OTHERWISE

DIRECTED BY THE ACTIVITY VIA THE CONTRACTING OFFICER).

3. PROVIDE CARD READER MOUNTING PLATES FOR BOTH SIDES (INBOUND &

OUTBOUND) OF TURNSTILE. CARD READER WILL BE INSTALLED BY THE

ACTIVITY AT A LATER DATE.

4. BRACE BARRIER POST AT TOP TO ADJACENT VERTICAL SURFACE.

5. ALLOW 8 INCH CLEARANCE ABOVE TOP OF TURNSTILE TO REMOVE LIFT-OFF

TYPE TOP COVER.

6. SET CONCRETE MOUNTING SLAB LEVEL WITHIN 1/4". MINIMUM SLAB

DIMENSIONS ARE 60"X66" FOR SINGLE TURNSTILE AND 96"X96" FOR TANDEM

TURNSTILE.

7. FINISH TURNSTILE TO MATCH ADJACENT FENCEWORK: POWDER COATED

BLACK FOR ORNAMENTAL FENCE.

T

Y P

6' - 0"

E

L E

C T

R I C

A L

5' - 0"

RED & GREEN

INDICATOR LIGHTS

(04) CEILING PL

(02) TOP CHANNEL

CARD READER MOUNTING

PLATE (EA SIDE)

(05) SHIELD ASSEMBLY

WELDED

BARRIER BARS

END TUBE

(06) ROTOR ASSEMBLY WELDED

FINISH GRADE

(03) POWER

CONNECTION

110 VAC

(01) BARRIER

ASSEMBLY WELDED

ANCHOR BOLTS

BARRIER POSTS

WELDED ALL AROUND TYP.

BOTTOM FLANGE

(08) BOTTOM BEARING

(07) POWDER COATED

ALUMINUM BASE

PLATE

CONCRETE MOUNTING PAD

SEE DETAIL THIS SHEET

02 03

ISOMETRIC VIEW

BOTTOM BEARING DETAIL ELEVATION

PLAN

TURNSTILE MOUNTING SLAB

3/4" CHAMFER

CONCRETE MOUNTING SLAB

SIDEWALK

LEFT HAND GATE SHOWN.

GATE TO BE BRACED AT TOP.

EC: GALVANIZED STEEL

ECP: POWDERCOATED STEEL

ES: STAINLESS STEEL

VOLTAGE: 24 VDC REQUIRED (FOR LOCK).

OPTIONAL POWER SUPPLY AVAILABLE.

AUTHORIZATION REQUIRES DRY CONTACT

FROM ACCESS CONTROL.

1. FRAME - WELDED

2. DOOR - WELDED

3. HINGE - STAINLESS STEEL

4. CLOSER - HYDRAULIC (MOTORIZED AVAILABLE)

5. STOP PLATE -STAINLESS STEEL

6. HANDLE - STAINLESS STEEL

7. LOCK - ELECTRIC STRIKE WITH PANIC BAR (ALTERNATIVE

LOCKS AND EXIT HARDWARE AVAILABLE)

8. PANIC BAR GUARD AND EXPANDED MESH (LEXAN SHEET

AVAILABLE)

B

B

SECTION B-B

5.00 [127.0 mm]

6.44 [163.5 mm]

2.25 [57.2 mm] m m m m m m m m

35.99 [914.3 mm]

CLEAR OPENING WIDTH

(48.00 [1219.2 mm] AVAILABLE)

THIS VIEW FROM

NON-SECURE SIDE

42.81 [1087.4 mm]

OVERALL WIDTH (36"

COW)

OR

54.81 [1392.2 mm]

OVERALL WIDTH (48"

COW)

FIHISHED FLOOR

CONDUIT

40.81 [1036.6 mm] (36" COW)

52.81 [1641.4 mm] (48" COW)

4.00 [101.6 mm]

Ø1.50 [Ø38.1 mm]

CONDUIT STUB UP

(2 PLCS.)

FOR 3/8" [10 mm] ANCHOR BOLTS

SECURE

NON-SECURE

A3 ACCESSIBLE SIDE GATE

NTS

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

W A

S H

IN

G

TO

N

P -7

W

A R

G A

M

IN

G C

E N

TE

R

08/17/2020

N E

W

S

H E

E T

I S

S U

E

C I V

I L

S

I T

E

D

E T

A I L S

AS NOTED

CS511

NTGCLZCLZ

01/04/2021

File details come from the government source that posted it. Updated .