Text version

AS SHOWN

DIRK KELLAR, SAFETY DIRECTOR, JMTC

BULBOACA TRAINING AREA

MOLDOVA ARMY TRAINING AREA

CONCEPT DESIGN: 25.06.2013

25. JUNE 2013

CJB

FOR VEHICLE TARGET PITS

TYPICAL VEHICLE TARGET PIT

LAYOUT

SCALE 1 : 50

A A

GRAVELED AREA

SLOPE 2%

DIRECTION OF FIRE

SECTION A-A

PROTECTION TIMBER 15/15 cm

PREFABRICATED L-SHAPE CONCRETE PARTS

SLOPE 2 %

THICKNES OF BERM CREST = 3 METER MIN

TOP VIEW FRONT VIEW SIDE VIEW

SCALE 1 : 25

5R

PREFABRICATED CONCRETE FIRING POSITION

SCALE 1 : 20

SIDE VIEW FRONT VIEW

TRANSPORT ANCHORS MUST BE TYPE "FREMEDA"

TOP VIEW

PREFABRICATED CONCRETE ELEMENT

TYPICAL PERSONNEL TARGET PIT INSTALLATION

GRAVEL 0-56 mm

GRAVEL 40/60 mm

COMPACTED SUBBASE

CROSS SECTION

SCALE 1 : 10

FOR PERSONNEL TARGET PITS (SIT)

GEOTEXTILE

POTENTIAL EQUALIZATION BUSBAR

ELECTRICAL POWER PANEL

RUBBER MAT

CONCRETE PREFAB ELEMENT

TOP VIEW

SIDE VIEW

SCALE 1 : 20

PREFABRICATED CONCRETE ELEMENTS

PREFABRICATED CONCRETE SLAB

11412

10612

10612

"ATTENTION: ALL PREFABRICATED ELEMENTS MUST BE EQUIPED WITH THE SAME TRANSPORT ANCHORS!"

POTENTIAL EQUALIZATION BUSBAR

BLOCKOUT FOR CABELING, DN 100

ELECTRICAL POWER PANEL

POTENTIAL EQUALIZATION BUSBAR

ELECTRICAL POWER PANEL

SIDE VIEW SIDE VIEW

L-SHAPE ELEMENT

SLAB

SIDE VIEW

TOP VIEW

SCALE 1 : 20

SCALE 1 : 20

CABLE JUNCTION BOX

CABLE JUNCTION BOX

LONG GALVANIZED GROUNDING ROD

EACH TARGET PIT WILL BE EQUIPPED WITH A 3m

Details Target Pits and Prefabricated Concrete Elements

TYPICAL DETAIL FOR NEW ROADS, WALKWAYS AND PARKING AREAS

FINAL DESIGN: 03.12.2013

UPGRADE MULTI PURPOSE AND 300 M RANGE

RANGE 1,2 AND 3

PRE FINAL DESIGN: 30.08.2013

13. Feb 20141 DELETION OF ELECTRICAL SYSTEM 300 M RANGE HELMUT SCHWINDL

File details come from the government source that posted it. Updated .